Digital Engine Tachometer

Similar documents
High-Precision Fuel Flow Meters

AR-7240B ANALOG ENGINE TACHOMETER INSTRUCTION MANUAL ONO SOKKI CO., LTD.

Analog Input Terminal

SPSR-115/230. Self-Powered Sensor

Analog Output Terminal

High-Precision Fuel Flow Meters

St epping Mot or s C-i ORIENTAL MOTOR GENERAL CATALOG 2009/2010

Motorized Linear Actuators. EZS Series SPV Series EZC Series EZA Series PWA Series

Switching Power Supply

10 AMP POWER RELAY. Breakdown voltage* 2. Operate time* 3 (at nominal voltage) Shock resistance. Vibration resistance. Unit weight

EPS/ELA-Series User Manual EPS/ELA 250W

Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES

Sorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes

SPSR-115/230. Self-Powered Sensor

Digital Flow Switch (Sensor Part) Operation Manual

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Hour Meter Series HM36

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

SHIMADEN SINGLE-PHASE THYRISTOR POWER REGULATOR

Low Profile DC Power Supply with Zero Voltage Soft Switching

MagFlux Q 8200 Series

Technical Explanation for Inverters

Brake Pack SB50W. Standard AC Motors A-143. Standard AC Motors Intro duction. Brake Pack. AC Speed Control Motors Inverter.

Turbidity and Suspended Solids Transmitter

Low voltage AC drives. ABB component drives ACS to 2.2 kw / 0.25 to 3 hp Catalog

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

High-Efficiency AR Series. RK Series /0.72 /Geared. CRK Series. RBK Series. CMK Series. 2-Phase Stepping Motors A-278.

0.6A, 1.5A, 2.25A, 3A/Phase

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Emergency lighting units EM powerled

HYDRUS ULTRASONIC METER

3550 series BATTERY HiTESTER

ProMinent Sigma/ 3 Motor Diaphragm Metering Pumps

FLAT/VERTICAL TYPE HIGH POWER BIFURCATED CONTACT

Stepper Motors ver ver.5

Continental Hydraulics Installation Manual CEM-AA-A

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Inverter Resistance Welder/Horizontal Pressure Head NRW-IN8400A/NA-184 Now Available

Weatherproof Tubular Slip Ring Assembly

COMPACT BUT CUT OFF DC POWER CURRENT, POWER CAPSULE CONTACT RELAY

Speed Sensors Line Guide

User Guide. Panel Mount Digital Tachometer. Model Washington Street Melrose, MA Phone Toll Free

User Guide. Model Insulation Tester / Megohmmeter. Introduction

TL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information

Speed Sensor. Inputs: Safety Information. Outputs. Wiring Diagram. Electrical Data: NOTICE

MD2U Series 2-Phase Unipolar Stepper Motor Driver

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS

EDG6000 Electronic Digital Governor

EZS. Motorized Linear Slides. Series. RoHS-Compliant

Connection and Operation (Speed Control)

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

2-Color Display High-Precision Digital Pressure Switch

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)

2-Color Display High-Precision Digital Pressure Switch

Temposonics. G-Series Analog Redundant. Magnetostrictive Position Sensors. Redundancy for enhanced safety

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Temposonics. E-Series Analog + Start / Stop. Magnetostrictive Position Sensors. Temposonics EP Measuring range mm / mm SENSORS

INSTRUMENTATION & CONTROL

Temposonics. M-Series Analog Redundant. Absolute, Non-Contact Positions Sensors. Temposonics MT Measuring length mm

AS Series. RK Series. UMK Series ASX Series 0.36 /0.72. CRK Series. CMK Series 1.8. RBK Series. PK Series 1.

Magnetic-Inductive Flow Meter FMI

TL RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, etc. ORDERING INFORMATION TYPES. High Load Relay for Smart Junction Box ACTL.

PG-30 PRESSURE GAUGES P G R - N FEATURES MODEL NUMBER DESIGNATION

1 Form A 5A small size power relay for interface

HIGH POWER SOLENOID DRIVER 1

Rated load current (resistive load) SRP. Min. 0.9 (max. 25 of difference between voltage phase and current phase)

Servo Motors B-1. Introduction B-2. NX Series B-9. Accessories B-47

ECP180 Series. Low 1 Profile. High Power Density. 2.0 by 4.0 Footprint. 120W Convection-cooled Rating. 180W Force Cooled Rating

Servo Motors C-7. Overview. Tuning-Free NX. Tuning-Free NX Series. Servo Motors. Page. NX Series C-8 C-7

Analog input module. Brief description. Page 1/8. Data Sheet

Temposonics. M-Series Analogue / SIL2* Absolute, Non-Contact Position Sensors. Temposonics MH Measuring Length mm

Model Insulation Tester / Megohmmeter. User Manual

NX Series. Tuning-Free AC Servo Motor Unit

Advanced Test Equipment Rentals ATEC (2832)

MIDDLE LOAD RELAY FOR SMART J/B

35 35A 50 50A 1 Single phase. Solid state power controller

Surface mounting, flush mounting, and DIN track mounting

150 WATT HEW SINGLE SERIES DC/DC CONVERTERS

Uninterruptible Power System

15A (2 Form C), 10A (4 Form C) COMPACT POWER RELAYS WITH HIGH SENSITIVITY

Stepping Motor and Driver Package. High-Efficiency AR Series. DC Power-Supply Input. Built-in Controller Type Pulse Input Type

DGC-2020 DIGITAL GENSET CONTROLLER

GENSET CONTROL MODULE A121A / A241A

REGENERATIVE BATTERY PACK TEST SYSTEM MODEL 17020

Sorensen XG Series / XTR Series W A. 850 W, 1U Half Rack Programmable DC Power Supplies V

Hybrid Control System, Alpha Step

CATALOG. ABB micro drives ACS55, 0.18 to 2.2 kw

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions

BLH. 24 VDC Input 15W / 30W / 50W / 100W BLH

MAGTROL. TF Series Torque Flange Sensor. TF data sheet FEATURES. DESCRIpTION. AppLICATIONS

DLRO 10 and DLRO 10X. Digital Microhmmeter. DLRO 10 and DLRO 10X Digital Microhmmeter. NEW interchangeable test lead terminations

Differential Expansion Measurements on Large Steam Turbines

IGNITION SYSTEM COMPONENTS AND OPERATION

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES

PG-30 PRESSURE GAUGES P G R - N MODEL NUMBER DESIGNATION

13A-1 FUEL CONTENTS MULTIPOINT FUEL INJECTION (MPI) FUEL SUPPLY... 13B

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

An Innovative Flow Sensor

Transcription:

Digital Engine Tachometer CT-6700 Compact and portable design

Compact Tachometer for various engine measurement The CT-6700 is a digital engine tachometer to measure rotation speed of gasoline/diesel engines, motors equipped on electric vehicles/hybrid electric vehicles, and general rotating bodies. Compact, space-saving design provides good operability and portability not only measurement on an engine test bench but also an actual vehicle. 1 High response measurement 4 Measurement by ECU crank pulse signal of unequal interval pulses (option: CT-0672) CT-6700 captures transitional phenomenon of engine rotation speed with high response. The analog output follows the acceleration/deceleration behavior within the conversion time of 1 cycle+8 µs of input signal. The signal is output as a wave-shaped pulse, which enables the engine rotation speed to be sent without delay. High speed digital output is also possible with CAN coutput function. The CT-6700 uses the ECU crank pulse signal to measure engine rotation. The signal captured by the ECU has unequal intervals because gear teeth are arranged at unequal intervals to detect the top dead center. At a particular point, a lack or excess of gear teeth may be detected, making it impossible to measure engine rotation speed with a pulse signal that is output irregularly. The CT-6700 ensures reliable measurement through learning pulse patterns of irregular output. Analog output Within input signal + 8 µs of high speed response [Example] Lack of gear teeth Measurable by ECU crank pulse signal 2 Wide variety of detectors can be used By using the ECU crank pulse signal output, it is possible to measure various engine rotations that could not be measured before, in addition to ten types of detector such as an ignition pulse detector, gasoline/diesel engine rotation detector, and magnetic rotation sensor. 5 Compact and easy to use Compact, potable, and flexible design (170:W x 49:H x 120:D). Excellent readability makes it easy to set functions by selecting menu options. Also, you can easily select frequently-altered items, such as sensor type, pulse count and trigger, with the relevant direct keys. 3 Automatic setting of trigger with the Trigger Assist Function Engine and motor rotations are measured after adjusting the trigger. Ignition signals may contain various noises and it takes time for adjustment. This trigger assist function speeds up adjustment of the trigger. NORMAL DIRECT MENU Trigger BAR GRAPH Automatic setting of trigger MENU

Various functions to help measurement Pulse output function for tracking analysis High speed digital data CAN output function (option CT-0671) Tracking analysis can be performed by reading DIRECT pulse output of CT-6700 (signal for rotation synchronization) with DS series of Ono Sokki. Motor rotation detector The horizontal axis is standardized with the rotation speed and the peak variation along with the rotation fluctuation is displayed as tracking diagram. Pulse output Vibration Sound Tracking diagram Rotation speed s rotation speed data in CAN communication. The output update cycle is 1 khz at maximum. Any CAN-communicated devices, such as a CAN logger, can be used to record rotation speed data. Baud rate 125, 250, 500, 1000 (kbps) Update frequency OFF, 1, 2, 5, 10, 20, 100, 1000 (Hz) Deceleration calculation function supports the measurement in engine stop DS-3000 series for tracking analysis Comparator function for monitoring engine measurement status The CT-6700 recognizes that the engine started when the engine run set value is exceeded. When the over run set value is exceeded, it is regarded as an engine failure and the contact point is output. The following graph shows an example when the engine run is set to 500 r/min and the over run is set to 6000 r/min. Over run setting 6000 r/min When an engine stops suddenly, no pulse signal is generated, making it difficult to determine whether the engine tachometer stopped or not. This issue is solved by performing precalculation. The rotation signal of 0 r/min is output after the stop time that was expected from the last detected signal interval or after the set time has elapsed. Stop time of estimate calculation (ESTIMATE) Ignition signal Input pulse Keep time (KEEP) Analog signal output Engine run setting 500 r/min 0 V 0 V Operation of over run ON Stop time (setting: x 5) Stop time 1000 ms Operation of engine run ON Application 1 Application 2 Measurement on an Engine Bench Measurement on an Actual Vehicle The CT-6700 does not need much place with its compact design even if it is set to an operation desk. Panel mount fitting or other assisting jig are also helpful for installation into a control panel. Mounting example of CT-0673: Panel mount fitting (option) Mounting example of CT-0674: Panel mounting jig (assisting jig for replacement from CT-6520B, option) Compact design makes it useful for measurement on an actual vehicle. Mounting example of CT-0676: Light shielding hood (option)

Wide variety of engine rotation measurement Digital Engine Tachometer CT-6700 For Gasoline Engine VP-202/1220 Engine vibration detector MP-9100/911 Electromagnetic rotation detector IP-3000A Ignition pulse detector IP-3100 Ignition pulse detector IP-292/296 Ignition pulse detector For Motor and Gasoline Engine Detection point : Conductor of ignition coil primary side, current cable of electronic distributor Code diameter : max. ø5 mm : 8 (W) x 14.3 (H) x 30 (D) mm Weight : approx. 80 g (cable included) Detection point : Conductor of ignition coil primary side (IP-292), Conductor of ignition coil secondary side (IP-296) : 0 to 10,000 r/min (depending on a display unit) : 102 (W) x 48 (H) x 30 (D) mm Weight : approx. 280 g OM-1200 Motor / gasoline engine RPM detector, EV/HEV, motor : Electromagnetic induction type Signal cable : MX-005/010/015/020 (sold separately) : 0 to 80 ºC : ø16x 54 mm (sensor) ø16 x 80 mm (sensor with connection cable) Weight : approx. 65 g OM-1500 Motor / gasoline engine RPM detector, EV/HEV, motor : Electromagnetic induction type : 4.9 m (direct-attached) : -10 to100 ºC : ø16x 30 mm Weight : approx. 130 g (cable included) Detection point : Conductor of ignition coil primary side / secondary side, current cable of electronic distributor Code diameter : max. ø10 mm : 13 (W) x 33 (H) x 60 (D) mm Weight : approx. 130 g (cable included) Ignition IP series Alternator OM-1500 : 4-cylinder diesel engine, 4-cylinder gasoline engine : Electromagnetic vibration detection type : 500 to 10,000 r/min : 2.9 m (direct-attached) : 0 to 100 ºC : ø25 x 50 mm Weight : approx. 110 to 130 g Engine or engine mount VP series Reflection mark on a rotating body LG series LG-9200 Optical rotation detector voltage : 2.0 Vp-p or more (1 khz, load 10 kω) M=1, gap=0.5 mm Rotation speed : 200 to 35,000 r/min (60 P/R) Detection gear optimum module : 1 to 3 Detection distance : 0.5 to 1 mm : not needed : MP-9100 ø20 x58.5 (L) mm MP-911 ø20x 64 (L) mm Weight : MP-9100 approx. 90 g MP-911 approx. 300 g (cable included) Others : MP-930 Oil proof type MP-935 Oil proof & heat resistant type MP-9120 Low impedance type MP-981/9820 Magneto-electric rotation detector waveform : Square Hi ; 5±0.5 V Lo ; 0.5 V or less : MP-981 1 Hz to 20 khz MP-9820 1 Hz to 100 khz Detection gear : Ferromagnet, gear width 3 mm or more, module 0.5 to 3 type : Floating ground impedance : approx. 330 Ω : -10 to 70 ºC : 12±2 VDC, approx. 40 ma (at 12V) : 75 mm (length) Weight : approx. 80 g (including 2 pcs. of mounting nut) : Photoelectric reflection using visible light Detection distance : 20 to 40 mm (when using 12 mm square reflection mark) Light source : Light emitting diode (red visible light) Max. response speed : 40 m/s (Peripheral speed conversion of rotating shaft) waveform : Rectangular Hi ; 5 ±.05 V Lo ; 0.5 V or less impedance : 1 kω or less : -10 to 60 ºC : 12±2 VDC, approx. 60 ma (at 12 V) : 21 (W) x 24 (H) x 117 (D) mm Weight : approx. 150 g (including 2 pcs. of mounting nut) * The above is an example of measurement. The setting location may be different depending on a vehicle type. * Measurement may not be performed or measurement range may be changed depending on an engine type.

Specification IP-292/296/3000A/3100, OM-1200/1500, Applicable VP-202/1220, LG-9200, MP-900/9000 series/981, detectors EXT(PULSE), ECU crank pulse signal (option) IP-292/296/3000A/3100 Input OM-1200/1500 Section Measurement VP-202/1220 120 to 20000 r/min range CRANK PULSE MP-900/9000 series 30 to 99999 r/min MP-981, LG-9200, TTL 0 to 99999 r/min Type (size) Fluorescent display tube (52.5 x 11.5 mm) Display Display range 0 to 99999 r/min* 1 Accuracy ±0.01 %F.S (±1 count) or less range 0 to 10 V Range setting 1 to 99999 r/min (set in steps of 1 r/min) Analog Load resistance 100 k or higher Response Updates in less than 8 µs after cycle becomes stable DIRECT : Wave-shaped output item 0.5 [P/R]: r/min value to obtain 0.5 P/R (selectable) 1 [P/R] : r/min value to obtain 1 P/R Pulse 60 [P/R] : r/min value to obtain 60 P/R 0 to 5 V logic signal Signal (Lo: 0.4 V or lower, Hi: 4.5 V or higher) Load resistance 100 k or higher Item Engine run, Over run Setting range 1 to 99999 r/min Contact Contact capacity 30 VDC/0.1 A Connector (cable side) Phoenix Contact MVSTBR2, 5/4-ST-5, 08 Digital Interface RS-232C/CAN (option) Moving average 2 to 720 times Selection of time or cycle Deceleration Time : 1 to 1200 ms calculation Cycle : x1.5 / x3 / x5 / x8 / x16 Other Automatic setting of trigger employed until Function Trigger assist pulse detection Resume Preserving condition values even while power is off Condition Maximum of five types of condition memory can be memory saved. General Specification Power requirement mass 9 to 28 VDC, 12 VA or less AC adapter (100 to 240 VAC, 36 VA or less) Input cable with fuse clips on both ends option 170 (W) x 49 (H) x 120 (D) mm (approx. 700 g) Operating temperature 0 to +50 C* 2 range Operating 5 to 85 % (with no condensation) humidity range Low Voltage Directive : 2014/35/EUEN61010-1 class 1 (When AC adapter is used.) EMC Directive : CE marking 2014/30/EUEN61326-1 class 1 Industrial Environment RoHS Directive : 2011/65/EUEN50581 FCC 47 CFR Part 15 Subpart B Class A Rubber foot x 4 Accessory AC adapter x 1 (100 to 240 VAC) Instruction Manual x 1 *1 Depending on the sensor and set value. *2 AC adapter operating temperature range: 0 to +40 C. Product List Model name Product name CT-6700 Digital Engine Tachometer (main unit) CT-0671 CAN output function CT-0672 ECU crank pulse signal input function* 3 CT-0673 Panel mount fitting CT-0674 Panel mounting jig (assisting jig for replacement from CT-6520B, option)* 4 CT-0675 Protection handles CT-0676 Light shielding hood *3 Enables to measure the engine rotation speed form the ECU crank pulse signal. *4 For using CT-0674, CT-0673 is necessary. Outer Dimensions (unit mm) 8-M3 (including opposite surface; hole for optional mounting screw) 49 20 170 (15) 61 120 (18) CAN connector (optional) 208 +1 0 4-M5 182 +1 0 49.6 0 +0.5 25 ±0.2 Recommended panel dimension with panel mount fitting (option) WORLDWIDE ONO SOKKI CO., LTD. 1-16-1 Hakusan, Midori-ku, Yokohama, 226-8507, Japan Phone : +81-45-935-3918 Fax : +81-45-930-1808 E-mail : overseas@onosokki.co.jp Outer appearance and specifications are subject to change without prior notice. * URL: http://www.onosokki.co.jp/english/english.htm U.S.A. Ono Sokki Technology Inc. 2171 Executive Drive, Suite 400, Addison, IL. 60101, U.S.A. Phone : +1-630-627-9700 Fax : +1-630-627-0004 E-mail : info@onosokki.net http://www.onosokki.net THAILAND Ono Sokki (Thailand) Co., Ltd. 1/293-4 Moo.9 T.Bangphud A.Pakkred, Nonthaburi 11120, Thailand Phone : +66-2-584-6735 Fax : +66-2-584-6740 E-mail : sales@onosokki.co.th INDIA Ono Sokki India Private Ltd. Plot No.20, Ground Floor, Sector-3, IMT Manesar Gurgaon-122050, Haryana, INDIA Phone : +91-124-421-1807 Fax : +91-124-421-1809 E-mail : osid@onosokki.co.in P.R.CHINA Ono Sokki Shanghai Technology Co., Ltd. Room 506, No.47 Zhengyi Road, Yangpu District, Shanghai, 200433, P.R.C. Phone : +86-21-6503-2656 Fax : +86-21-6506-0327 E-mail : admin@shonosokki.com Recycled Paper CAT.NO.1435-01E Printed in Japan 166 (SUN) 1K