Z100A Clinical Centrifuge

Similar documents
SPECTRAFUGE 6C. User Manual C0060 C V

INSTRUCTION MANUAL FOR THE CLINICAL 50 CENTRIFUGE

Spectrafuge 24DMicrocentrifuge User Manual C2400 C V C V

Instruction Manual. Labnet Spectrafuge 16M Microcentrifuge

Clinispin CT20 User Manual

Prism Microcentrifuge

Instruction Manual. Labnet Spectrafuge 7M Microcentrifuge

Instruction Manual for Microlitre Centrifuge Z 160 M

CONTENTS. 3 MAINTENANCE 3.1 Service and Maintenance Maintenance and cleaning Glass breakage Disinfection

INSTRUCTION MANUAL FOR BENCH TOP CENTRIFUGE Z 200 A

Instruction Manual for the Revolutionary Science RS-200 RevSpin Microcentrifuge

INSTRUCTION MANUAL. CAT Place Table Top Centrifuge

Instruction Manual for the Revolutionary Science RS-102 RevSpin Microcentrifuge

Submersible Pond Pump with UV 800 Gallons Per Hour

Operators Manual. Model 3370 Air Cooled Recirculator rev.8/98

Spotlight 1,000,000 Power Series Cordless Rechargeable

OWNER'S MANUAL. Royal Sovereign International Inc. RET Desk Series

Mechanical Filter Pump Kit Up to 500 gallons

Model 700 Microarray Oven

RENA AF371Feeder Operating Manual. Feeder. Operating Manual. Manual Part #: M AF371 Operations Rev

FlexChem Model 404 Rotating Oven

Mechanical Filter Box Kit

CLEMENTS. Orbital 160 Benchtop Centrifuge. CEN V 50Hz. User Manual. Manual No. CEN Issue 4

materials and workmanship for 2 years. Should the centrifuge require warranty or Phone: or Fax:

Air-Operated Waste Oil Drainer

INSTALLATION INSTRUCTIONS SINGLE HORIZONTAL ACCESS DOOR PANTRY INSERT MANUAL

Twin-Beam Spotlight 3,000,000 Power Series Corded Cordless Rechargeable

Defender 3000 Series Base Instruction Manual

Technical Information Manual

MV Series Motors Operation & Parts Manual. Models M3V, M5V, M5V-US

CLEMENTS. Orbital 260 Benchtop Centrifuge. CEN V 50/60Hz. User Manual. Manual No. CEN Issue 5

30 Amp Solar Charge Controller

Container Fountain Kit with LED Light

XPC-EBP64 External Battery Pack User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

OWNER S MANUAL. Dick s Sporting Goods 345 Court Street Coraopolis, PA Tools Required: Allen Wrench

POST LANTERN ITEM # MODEL #39487 ATTACH YOUR RECEIPT HERE. Serial Number. Purchase Date

12 Volt Heavy-Duty Air Inflator

Premium Pond Pump 330 Gallons Per Hour

HTR-202 INSTRUCTION MANUAL. Portable Digital Height Rod. Befour, Inc. 102 Progress Drive Saukville, WI 53080

Adjustable Shop Stool with Backrest

Centrifuge Operator / Service Manual

DWS404 DWS524 DWS654 DWS684 DWS694. DWS SERIES INSTALLATION/OWNER'S MANUAL Car Audio Speakers

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

1200W Paint DRYING Lamp

Centrifuge. Model XC-1000 Operating Manual

OPERATIONS MANUAL. Mini Centrifuge Model MCF Certified

Operators Manual. Recirculating Chiller /06/08

Submersible Waterfall Pump 1200 Gallons Per Hour

USER MANUAL. Tides La Mer Treatment Table Rev A 3/28/19. *all tables shown with optional accessories and/or finishes

Natural Fiber Planter Fountain

Model : LMHS-60 Please read this manual carefully before using the instrument Labnics Equipment

900 PEAK AMP PORTABLE JUMP STARTER

Premium Waterfall Pump 1200 Gallons Per Hour

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

Triple Output High Resolution Power Supply. User Manual

Heavy-Duty Sawhorse. Owner s Manual

CTFRP Series Power Supplies

FLAT BENCH OWNER S MANUAL QUESTIONS? CAUTION. Visit our website at.

VSM480. Instruction Manual VARIABLE SPEED MIXER. Read instructions before operating this tool.

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

OPERATION and MAINTENANCE INSTRUCTION MANUAL

FLAT BENCH OWNER S MANUAL QUESTIONS? CAUTION. Visit our website at.

Laboratory Centrifuge Model GF614B

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

USER S MANUAL & WARRANTY INFORMATION

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

QPET, QPETXU Battery Chargers

Low-Water Auto Shutoff Pump 420 Gallons Per Hour

SAVE THESE INSTRUCTIONS

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

Tissue Master. User Manual

Broadband PowerShield. External Battery Pack 20 Ah 12 V Battery. User Manual

Mod: KLD6-12/35XLAS-N

ANGLE DIE GRINDER KIT

MV Series Motors Operation & Parts Manual

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Heavy-Duty Welding Fabrication Table

16 Inch Surface Cleaner

Customer Support

1000-LB. MOTORCYCLE LIFT TABLE OWNER S MANUAL

Pressurized Pond Filter Up to 850 gallons

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

BMRX Series ROTARY LEVEL CONTROL

TBX10A INSTALLATION/OWNER'S MANUAL 10" Sealed Enclosure with Built-in Amplifier

steady cool fluorescent IUF-55 INSTRUCTIONS

FD Conveyor for FD 260 Tabber

POST LANTERN ITEM # MODEL #39434 ATTACH YOUR RECEIPT HERE. Serial Number. Purchase Date

IV STANDS. Assembly, Usage and Maintenance INSTRUCTION MANUAL

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases

16 Inch Hanging Pendant Barn Light

Adjustable Steel Welding Table

Installation & Operation Manual Chef Base

Hybex Microsample Incubator

APEX JD-3.1 HYPER EXTENSION BENCH

i n s t r u c t i o n m a n u a l

USER'S GUIDE 9151 SERIES V

MARCY DIAMOND ELITE OLYMPIC BENCH MD-857. Model MD-857. Retain This Manual for Reference OWNER'S MANUAL

SUBMERSIBLE MINI-PUMP

NEUTRALIZATION SYSTEM FOR OPA & GLUTARALDEHYDE MEDI-NEWT. User Manual. Endoscope reprocessing the the way way it it should be be

2-in-1 Air Operated Waste Oil Drainer

Transcription:

Z100A Clinical Centrifuge User Manual C0100-A Rev 2 August 2016

About This Manual This manual is designed to assist you in the optimal usage of your Labnet Z100A Clinical Centrifuge. The manual is available in English, French, German, Italian, Portuguese, and Spanish on our website at www.labnetinternational.com/document-center

Safety Precautions NEVER NEVER NEVER NEVER NEVER NEVER NEVER NEVER ALWAYS ALWAYS ALWAYS ALWAYS use the centrifuge in any manner not specified in these instructions. operate the centrifuge without a rotor properly attached to the shaft. fill tubes while they are in the rotor. Liquid spillage may harm unit. put hands in the rotor area unless the rotor is completely stopped. move the centrifuge while the rotor is spinning. use solvents or flammables near this or other electrical equipment. centrifuge flammable, explosive or corrosive materials centrifuge hazardous materials outside of a hood or proper containment facility load the rotor symmetrically. Each tube should be counterbalanced by another tube of the same type and weight locate the centrifuge within easy access to an electrical outlet. use only centrifuge tubes designed to withstand centrifugal forces of at least 1,967 x g. use a wrench to tighten rotor nut.

Table of Contents 1. General Information 1 Description Safety precautions to be observed before operating Technical data Accessories Warranty 2. Installation 2 Unpacking the centrifuge Required space Cushion Installation Centrifuge Installation 3. Operation 3 Closing the lid Lid release Lid lock Starting the centrifuge 4. Proper use of the Rotor 3 Overloading the rotor Balancing the rotor Rotors and accessories 5. Service and Maintenance 4 Service of centrifuge Cleaning the centrifuge Disinfection Cleaning the centrifuge after breakage of glass tubes or bottles Replacing fuses 6. Troubleshooting guide 5 8. Determination of g-values 6

1. General Information This manual is intended for use with the Z100-A (C0100-A) Centrifuge. 1.1 Description The Z100-A is a small benchtop centrifuge designed for sedimentation of various samples. The Z100-A has a built in angle rotor capable of running up to 4,000 rpm (1,967 x g). 1.2 Safety precautions Note: All users of the centrifuge must read the Safety Precautions section of this manual before attempting to operate the unit! If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. Do not operate the centrifuge if any of the following conditions exist: -The centrifuge has not been installed properly -The centrifuge is partially dismantled -Service has been attempted by unauthorized or unqualified personnel -The rotor has not been installed securely on the motor shaft -Rotors and accessories not belonging to the standard range are being used without permission being obtained from the manufacturer to use such rotors and/or accessories in the centrifuge Exception: Centrifuge tubes, normally available in the laboratory. -The centrifuge is located in an explosive atmosphere -Materials to be centrifuged are combustible and/or explosive -Materials to be centrifuged are chemically reactive -The rotor load is not properly balanced 1.3 Technical data Dimensions Width Depth Height Maximum speed Maximum RCF Maximum volume 295mm (11.6in) 348mm (13.7in) 101mm (10.1in) 4,000rpm 1,967 x g 6 x 15ml Admiss. density 1.2kg/dm 3 Rotor radius Electrical/fuse rating 11cm 120V/50-60Hz, 1 Amp

1.4 Accessories supplied with centrifuge - One 6 x 15mL rotor - Six rubber cushions Additional accessories available: C0200-17A Combination adapters for 5mL and 7mL tubes, (6pk) 1.5 Warranty This centrifuge has been subject to thorough testing and quality control. In the unlikely event of a manufacturing fault occurring, our one year warranty (from the date of delivery) covers the centrifuge and the rotor. This warranty becomes invalid in the case of incorrect operation, use of nonstandard spare parts or accessories and unauthorized modification of the rotor or centrifuge. Labnet reserves the right to make technical modifications. Statements contained herein are not to be considered binding. 2. Installation 2.1 Unpacking the centrifuge The centrifuge is delivered in a carton with two or more formed foam blocks. Please retain the carton and the blocks until it has been established that your unit is working properly. The accessories supplied with the centrifuge should be kept with the instruction manual near the centrifuge s place of installation. 2.2 Required space The centrifuge should be installed on a rigid, even surface such as a stable laboratory bench, cabinet, etc. To guarantee sufficient ventilation, ensure that the centrifuge has at least 15cm (6 inches) of free space on all sides, including the rear. The centrifuge should not be located in areas subject to excessive heat such as in direct sunlight or near radiators or the exhaust of a compressor, as a buildup of heat may occur within the centrifuge bowl. 2.3 Cushion Installation Before inserting any tubes into the centrifuge the rubber cushions must first be properly installed. To install the cushions turn a 10 or 15mL round bottom tube upside down and place the cushion on top. Then remove the rotor shield and place it on top of the tube while pushing the cushion into the end of the shield. Then reinsert the shield.

2.4 Centrifuge Installation Make certain that the time is set for the off position. Before operating the centrifuge, check that the power source corresponds to that on the manufacturer s rating label, then connect the power cord to a properly grounded outlet. Attention: Ensure that the time is in the OFF position before connecting the power cord. 3. Operation Attention: Never operate the centrifuge if the rotor shows any signs of corrosion or mechanical damage. Never operate with strongly corrosive materials. 3.1 Closing the lid After the rotor has been properly loaded, close the centrifuge lid. 3.2 Lid release The lid button must be pushed to open the lid after a centrifuge run has been completed. 3.3 Lid lock The centrifuge can only be started with the lid closed. Do not attempt to open the lid until the rotor comes to a complete stop. 3.4 Starting the centrifuge To start the centrifuge select the desired run time by turning the time knob in a clockwise direction. If performing a continuous run turn the time knob counter clockwise into the hold position. Once a run time is selected a given speed must be selected in order to start the centrifuge. The speed (rpm) can be selected between 1,000 and 4,000rpm by turning the knob to the 1, 2, 3 and 4 speed marks. To select a speed, turn the speed knob to the 2 position to activate, then proceed by turning the knob to the desired speed. At the end of the preselected time, the centrifuge stops automatically. To stop the centrifuge prior to the selected time, turn the timer knob to the OFF position.

Note: The clinical centrifuge is calibrated at 120 volts line voltage. Operating the centrifuge at a line voltage other than 120V can significantly impact the speed settings below 2,000 rpm. 4. Proper loading of the rotor 4.1 Rotor capacity The rotor has been designed to handle samples with a maximum density of 1.2g/mL. Tubes should not be run with any substance having a density above 1.2g/mL. 4.2 Rotor loading When loading the rotor you should proceed according to sketch A. Fill the tubes equally by eye and insert them into the tube shields of the rotor. The difference in weight between the tubes should not exceed 2 3 grams. A partially loaded rotor may be centrifuged. For example, you may operate a 6-place rotor with 2, 3 or 4 loaded tubes, but it is important that the occupied tube shields are symmetrically arranged. (see sketch A) Sketch A: Examples of properly loaded rotors.

4.3 Rotors and accessories Angle rotor for 6 x 10/15mL tubes (included) Centrifuging radius 11cm Max RCF 1,967 x g Adapter C0200-17A: For 5mL (13 x 75mm) and 7mL tubes (13 x 100mm) Centrifuging radius 8.65cm Max RCF 1,547 x g 5. Service and Maintenance 5.1 Service of centrifuge There is no routine maintenance or service required on the centrifuge other than occasional cleaning. 5.2 General cleaning of the centrifuge Always keep the centrifuge housing, rotor chamber, rotor and rotor accessories clean. All parts should be wiped down periodically with a soft cloth. Do not use harsh Cleaners or detergants on the lid or housing surfaces as it may affect the plastic. After cleaning, ensure that all parts are dried thoroughly by hand or in a warm-air-cabinet (max. temp. +50ºC) 5.3 Disinfection The centrifuge should be disinfected periodically and before shipping the unit for service. The centrifuge rotor are and rotor shields should be wiped with alchohol or other disinfecting agents. Do not allow the alcohol or disinfectant to sit on the units lid or housing, as it may affect or discolor the plastic. 5.4 Cleaning the centrifuge after breakage of glass tubes or bottles With high g-values, there is a possibility that tube breakage can occur. Should this happen the centrifuge rotor must be thoroughly cleaned and all broken particles removed. If this is not done, damage could result to the centrifuge. If glass or other material has gotten into the centrifuge enclosure, the enclosure must be removed for cleaning.

5.5 Replacing fuses Check the fuse when it is recommended in the Troubleshooting Guide located in this manual. The fuse holder is located underneath the unit. Unplug the unit. Unscrew the fuse holder and remove the fuse. Replace a blown fuse with a fuse of equivalent rating and type. 6. Troubleshooting Guide Please refer to this guide before calling for service. Centrifuge will not start Possible reason: No power supply Solution: Check main power supply and centrifuge fuse Possible reason: Blown fuse Solution: Check fuse and replace if necessary (see 5.5) Lid lock will not release Possible reason: Lid lock is jammed Solution: Push front of lid down while pushing release button Centrifuge cannot be started, although power is on Possible reason: Lid not closed correctly Solution Close lid correctly, push down on front of lid Possible reason: No speed or time has been selected Solution: Check and set speed and/or time Possible reason: Blown fuse Solution Check fuse and replace if necessary (see 5.5) Should you have any questions about the centrifuge or its accessories, please call Labnet s Customer Service Department at 732 417-0700. Customer Service is staffed from 8:30am to 5:30pm, EST, Monday through Friday. Our 24 hour fax number is 732 417-1750. Inquiries may also be sent via our electronic mailbox at labnetinfo@corning.com. Should your Centrifuge require service, please call Labnet s Technical Services Department at 732 417-0700. Our Service Department is staffed from 8:30am to 5:00pm, EST, Monday through Friday. Our 24 hour fax number is 732 417-1750. Electronic mail may be sent to labnetinfo@corning.com. Please have the unit s serial number (located on the back panel of the instrument) available when calling. Should an item require return to Labnet for service, a repair return authorization (RA) number must first be received from Labnet. Items sent without an RA number will not be accepted.

8. Determination of g-values See section 4.3 for the correct radius of your rotor. Note the use of tube adapters will change the radius. To determine the relative centrifugal force (RCF-value). This value is the multiplier to the gravitational pull of the earth (g).

Notes:

EQUIPMENT DISPOSAL-EUROPEAN REGULATIONS According to Directive 2012/19/EU of the European Parliament and of the Council of 4 July 2012 on waste electrical and electronic equipment (WEEE), Labnet Z100A Clinical Centrifuge is marked with the crossed-out wheeled bin and must not be disposed of with domestic waste. Consequently, the buyer shall follow the instructions for reuse and recycling of waste electronic and electrical equipment (WEEE) provided with the products and available at the following link: www.corning.com/weee

LIMITED WARRANTY Labnet International Inc. warrants that this product will be free from defects in material and workmanship for a period of one (1) year from date of purchase. This warranty is valid only if the product is used for its intended purpose and within the guidelines specified in the supplied instruction manual. Should this product require service, contact Labnet s Service department at 732-417- 0700 to receive a return authorization number and shipping instructions. Products received without proper authorization will be returned. All items returned for service should be sent postage prepaid in the original packaging or other suitable carton, padded to avoid damage. Labnet International Inc. will not be responsible for damage incurred by improper packaging. Labnet may elect for onsite service for larger equipment. This warranty does not cover damage caused by accident, neglect, misuse, improper service, natural forces or other causes not arising from defects in original material or workmanship. This warranty does not cover motor brushes, fuses, light bulbs, batteries or damage to paint or finish. Claims for transit damage should be filed with the transportation carrier. ALL WARRANTIES INCLUDING THE IMPLIED WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION OF 12 MONTHS FROM THE ORIGINAL DATE OF PURCHASE. LABNET S SOLE OBLIGATION UNDER THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT, AT LABNET INTERNATIONAL INC. S. DISCRETION, OF A DEFECTIVE PRODUCT. LABNET INTERNATIONAL, INC. IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGE, COMMERCIAL LOSS OR ANY OTHER DAMAGES RESULTING FROM THE USE OF THIS PRODUCT. Some states do not allow limitation on the length of implied warranties or the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights. You may have other rights which vary from state to state. No individual may accept for, or on behalf of Labnet International Inc., any other obligation of liability, or extend the period of this warranty. Please register your product online at: www.labnetinternational.com Warranty/Disclaimer: Unless otherwise specified, all products are for research use only. Not intended for use in diagnostic or therapeutic procedures. Labnet International makes no claims regarding the performance of these products for clinical or diagnostic applications.

31 Mayfield Ave. Edison, NJ 08837 P: +732-417-0700 F: +732-417-1750 Toll Free: 888-522-6381 labnetinfo@corning.com www.labnetinternational.com 9299600000