Humidity. Characteristics. Applications. Capacitive humidity measurement, temperature measurement via Pt100/Pt1000 Sensor

Similar documents
Analysis ph / ORP. Applications. Characteristics. Food industry Chemical and Pharmaceutical industry Water and Sewage treatment

GHMsilverline Handheld Instruments

Magnetic Inductive Flow

Analysis ph / ORP. Characteristics System. Applications Food industry Chemical and Pharmaceutical industry Water and Sewage treatment

Flow - magnetic inductive - probe form

Product information Hygienic Design Turbidity

Product information Hygienic Design GHMadapt / Accessories

Pressure. Applications. Characteristics. Differential pressure Overload pressure, Vacuum, Absolute pressure, Flow ±0.3 mbar..

HUMIDITY / TEMPERATURE TRANSMITTER

A and B Series Sensors for Humidity and Temperature for industrial applications from C and up to 25 bar

Output signal active humidity DC V 22DTH-51MB DC V, DC V DC V DC V DC V DC V

A and B Series Sensors for Humidity and Temperature for industrial applications from C and up to 25 bar

A and B Series Sensors for Humidity and Temperature for industrial applications from C and up to 25 bar

Mini Pressure Transmitter HA7

Flow - rotor, inline model

Data Sheet SCHISCHEK EXCOS-P. Pressure sensor 20 Pa Pa. Supplied by. .com. Call us on +44 (0)

Magnetic-Inductive Flow Meter FMI

Magnetic-Inductive flow Meter fmi

Beck. The differential pressure transmitter for air with IP65

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Product information Flow Magnetic Inductive, Probe Form

Compact Pressure Transmitter DAN-HH

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

Class 100 temperature and humidity dataloggers

ExBin-P Pressure switches 5 Pa Pa

JUMO thermocor. Portable measuring system for AMS2750 and CQI-9. Brief description. Block diagram. Special features. JUMO thermocor.

Output signal active note. Measuring range rel. pressure. Electrical Data Power supply DC V, ±10%, 1.1 W

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4

Product information Hygienic Design Electromagnetic flowmeter

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Transmitters Sensors. Transmitters. Sensors. Pressure Temperature Humidity Air velocity Airflow

Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection

TEMPERATURE - HUMIDITY VAISALA HMP155

better measurement Simply a question of

Differential Pressure Sensors

InBin-P Pressure switches 5 Pa Pa

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

Pressure regulators E/P pressure regulators Series EV07. Brochure

Level limit switch Series RF 3000 Selection list

EGQ 212: Duct transducer, CO 2 and temperature

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

Portable pressure calibrator, Wally Box III Model CPH7600

Flow - dynamic diaphragm

Continuous level sensor NSK

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Continuous level sensor NSK

JUMO thermocor. Portable measuring system for AMS2750 and CQI-9. Brief description. Block diagram. Special features. JUMO thermocor.

SITRANS P measuring instruments for pressure

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

The right choice for your application. Pressure sensors from ifm.

Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH

Carbon Dioxide (CO2) + Humidity (rh) + Temperature (T) transmitter with Display for room mounting. Features

Level sensor Magnetostrictive, high-resolution measurement principle Model FLM-H, for sanitary applications

Differential Pressure Sensors

Pressure regulators E/P pressure regulators Series ED05. Brochure

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

AIR FLOW The Right Flow Sensor For Any Measuring Task. Pitot Tubes. Rotating Vanes. Thermoanemometers

better measurement Simply a question of

Differential Pressure Sensors

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Level Sensor with M12 Thread Hygienic

Differential Pressure Sensors

Flow VA 550 / 570. DVGW tested. Flow.

High-quality pressure sensor with mounted diaphragm seal With clamp connection Model DSS22T

Differential Pressure Transmitter

JUMO dtrans p20 DELTA

Insertion Temperature/Humidity/ Dewpoint temperature Sensor HTY78X3/HY78X3/HTY78X6/HY78X6/HY79X3

Differential pressure sensor

Sensor systems. Type Differential pressure transducer. For the differential pressure recording and control in combination with EASYLAB.

Pressure Transmitter

Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050

High-quality pressure sensor with mounted diaphragm seal With flange connection, flush diaphragm Model DSS27T

The Multivariable Air Flow Meter

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage

Pressure transmitter for general industrial purposes Type MBS 3000 and MBS 3050

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050

Level Sensor with G1/2" Thread Hygienic

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre

Intelligent Positioner

Optidew Vision Optical Dew-Point Meter

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Pressure transmitter UNIVERSAL CA

Pressure transmitter PASCAL CV4

High-quality pressure sensor with mounted diaphragm seal With threaded connection, welded design Model DSS34T

Figure 1: WPR2 Dimensions and Hardware

- Quicktemp TP62/TW39...T500 -

High-quality pressure sensor with mounted diaphragm seal With threaded connection, threaded design Model DSS10T

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

The Multivariable Air Flow Meter

HLX771/772. Inline Flowmeter for compressed air and gases DN15 (1/2 ) - DN80 (3 ) Typical Applications

RVP-R- VAV controller. In explosion-proof version

Pressure regulators E/P pressure regulators Series EV04. Brochure

Cable resistance thermometer Model TR40

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

Digital Pressure Gauge / Pressure Switch

Magnetic-Inductive Flow Meter FMQ

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

Transcription:

GHM Messtechnik GmbH Sales Center International Schloßstraße 6 88453 Erolzheim Germany Fon +49-7354-937233-0 Fax -88 www.ghm-messtechnik.de info@ghm-messtechnik.de Humidity Characteristics Applications System Evaluation Indicator Mounting mode Capacitive humidity measurement, temperature measurement via Pt100/Pt1000 Sensor Integrated transmitter with output for standard signals LCD-display Field case, duct shape, rod shape Indoor climate monitoring Cool- and stockrooms Greenhouses Food applications pi-ma-humidity_e V1.00-00 1

GHM Messtechnik GmbH Sales Center International Schloßstraße 6 88453 Erolzheim Germany Fon +49-7354-937233-0 Fax -88 www.ghm-messtechnik.de info@ghm-messtechnik.de Function The GHTU and RF90 are used for long-term monitoring, monitoring room air conditioning and the monitoring of warehouses. They are ofered with 1.5 m connection cables, plastic connection casing or with sturdy aluminium connection head and screw terminals to measure the relative humidity and temperatures in non-aggressive gases. Due to the sturdy surface-mounted casing, the measuring transducers are particularly suitable for use in industry. Advanta +e Compact Design integrated LCD display Device for high huimidity recommended measuring range 5..95% r.h Accessories for high humidity and outdoor applications Device overview Device Measuring ranges Model Output Page GHTU RF90 0..100 % r.h. -40.0..+100 C 0..100 % r.h. -30..+70 C Wall mounting, duct mounting Wall mounting, duct mounting 4..20 ma, 0..1 V DC, 0..10 V DC 4..20 ma, 0..10 V DC 3 5 Mistakes reserved, technical specifications subject to change without notice. 2 pi-ma-humidity_e V1.00-00

GHM Messtechnik GmbH - Location Greisinger Hans-Sachs-Straße 26 93128 Regenstauf Germany Fon +49 (0) 9402-9383 - 0 Fax -33 www.greisinger.de info@greisinger.de Produktinformation Humidity / Temperature Transmitter incl. Sensor GHTU GHTU - 2K Design type Length of probe / cable / hat outlet probe / cable surface design EL = 50 mm on the side surface / duct design EL = 220 mm on the side duct design EL = 220 mm bottom surface design with cable in distance to housing, 1 m Teflon cable on the side surface design with weather proofing Hat = 82 mm bottom GHTU - 1R On-site display for humidity and temperature Output signals freely scalable Several design types Characteristics GHTU - 1K GHTU - SHUT The EBHT is used for long-term monitoring, indoor climate monitoring and monitoring of storage rooms. The sensor module is particularly suitable for industrial applications due to its robust surfacemounted housing. Other features 1R / 1K / 2K KABEL SHUT Technical data Measuring ranges Humidity: Standard High humidity Temperature Measuring sensors Accuracy Humidity Temperature Electric connection Output signal Power supply Permissible burden Permissible load Display Housing Protection class : unscrewable protective cap with gauze filter insert made of stainless steel (105 μm mesh size) : includes high humidity sensor (HO) and varnished board (LACK) by default : weather protection shield made of plastic, reduces distortions by sun / rain, includes high humidity sensor (HO) and varnished board (LACK) 0.0..100.0 % RH recomm. measuring range: 20..80 % RH recomm. measuring range: 5..95 % RH -40.0..+100 C; 120.0 C < 1min (-40.0..+248.0 F) capacitive polymer humidity sensor and Pt1000 ±2.5 % RH (at recomm. measuring range) ±0.4 % of m.v. ±0.2 C elbow-type plug EN 175301-803/A, output 2-wire, max. 1.5 mm 2 each 2x 4..20 ma, 0..1 V, 0..10 V, freely scalable 12..30 V DC for 4..20 ma or 0..1 V 18..30 V DC for 0..10 V R A [Ω] = (U V [V] - 12 V) / 0.02 A R L [Ω] > 3000 Ω 10 mm high, 4-digit LCD-display ABS, working temperature: -20..50 C IP65 (housing) Due to the availability of several design types (like e.g. for surface or duct mounting, with sensor in distance to housing or with weather protection shield) the GHTU are appropriate for almost all applications. The housing of the module is made of robust ABS. The modules have an on-site display, therefore direct configuration is possible. Design types 1R 1K 2K KABEL SHUT continued on next page Dimensions 1R / 1K / 2K : 82 x 80 x 55 mm (H x W x D) (without probe/plug) tube-ø 14 mm KABEL : 82 x 80 x 55 mm (H x W x D) pi-ma-humidity_e V1.00-00 3

GHM Messtechnik GmbH - Location Greisinger Hans-Sachs-Straße 26 93128 Regenstauf Germany Fon +49 (0) 9402-9383 - 0 Fax -33 www.greisinger.de info@greisinger.de Produktinformation (without probe/plug) probe tube in distance to housing, sensor head (Ø 14 x 68 mm) SHUT : 82 x 80 x 55 mm ((H x W x D) (without probe/plug) shield Ø 110 mm, height 140 mm 1R 1K 2K the outlet is centred and pointing downwards (e.g. for direct mounting on plain duct surfaces) output signals are electrically isolated AV2 0..1 V, freely scalable, output signals are not electrically isolated AV3 0..10 V, freely scalable, output signals are not electrically isolated GV2 0..1 V, freely scalable, output signals are electrically isolated GV3 0..10 V, freely scalable, output signals are electrically isolated 4. Option (general) (combination of multiple options possible) 00 without option LACK board varnished on both sides (for outdoor usage) standard for types KABEL and SHUT UNI selectable humidity display unit Instead of displaying and output the standard humidity value you can change to one of the following values via interface or VO-display: wet bulb temperature dew point temperature enthalpy atmospheric humidity absolute humidity Ordering example: GHTU-KABEL-MP-HO-000-GA1-LACK-UNI Ordering code 1. 2. 3. 4. GHTU - - MP - - - 1. Design type 1R Surface design 1K Surface / duct design 2K Duct design KABEL Surface design with cable (incl. HO + LACK) SHUT Weather protective shield / heat-protective hat (incl. HO + LACK) 2. Option (sensor) 00 standard sensor (standard for 1K, 1R and 2K) (recomm. measuring range: 20..80 % RH) HO high temperature sensor (standard for KABEL and SHUT) (recomm. measuring range: 5..95 % RH) 3. Fitting length EL 000 without fitting length (for KABEL / SHUT) 050 length = 50 mm (standard for type 1R) 220 length = 220 mm (standard for type 1K / 2K) 300 length = 300 mm 400 length = 400 mm 500 length = 500 mm 4. Output signal GA1 4..20 ma, freely scalable, Accessories / Spare parts Spare protective cap made of plastic with gauze filter insert made of stainless steel (suitable for standard and high humidity) Brass filter (not suitable for high humidity) 4 pi-ma-humidity_e V1.00-00

GHM Messtechnik GmbH Location Martens Kiebitzhörn 18 22885 Barsbüttel Germany Fon +49-40-670 73-0 Fax -288 www.ghm-messtechnik.de info@martens-elektronik.de Humidity transmitter RF90 Dimensions / connection diagrams Rod shape Wall mounting Duct mounting Capacity measurement for non aggressive gases Analogue outputs 4..20 ma or 0..10 V DC Good dynamic performance Resistance against dew formation Operating temperature -20..80 C Characteristics Humidity-/temperature sensors of the series RF compact, versatile sensors in a rod-type design. They are available with a 1.5 m connecting cable without cable ( or with a robust aluminum connecting head and terminal screws for measuring relative humidity, relative humidity and temperature or temperature in air and other non-aggressive gases. The advantages of the series RF are its improved dynamics, in particular at low air speeds and also its increased service life. For extreme applications (near the sea, desert, mountains, areas with high air speed etc.) we recommend our stainless steel sinter filter Technical data Power supply Supply voltage Current output : 12..30 V DC Voltage output : 24 V DC ±10 % Operating temperature : -1,-3 : -30..+70 C -2 : -20..+80 C Ambient temperature : -40..+80 C CE-conformity : EN 61326-2-3 Output Humidity : 4..20 ma or 0..10 V DC Measuring range : 0..100 % r.h. Measuring element : FE09/1 Accuracy : ±2 % r.h. Temperature : 4..20 ma or 0..10 V DC Measuring range : -30..+70 C Measuring element : Pt100 class B Accuracy : ±0.3 K Burden current : 500 Ω at 24 V DC Load voltage Measuring delay : 10 kω : 60 s at airspeed 1 m/s for humidity and temperature Protection class Sensor : IP30 (standard with gauze filter) Case : IP54 Terminal head : IP65 Dew formation and splashes do not damage the sensor pi-ma-humidity_e V1.00-00 5

GHM Messtechnik GmbH Location Martens Kiebitzhörn 18 22885 Barsbüttel Germany Fon +49-40-670 73-0 Fax -288 www.ghm-messtechnik.de info@martens-elektronik.de Ordering code 1. 2. RF90 - - 1. Model 1 rod shape with 1.5 m connection cable 2 wall mounting 3 duct mounting 2. Output 1 rel. humidity 0..10 V DC 2 rel. humidity 4..20 ma 3 rel. humidity & temperature 0..10 V DC 4 rel. humidity & temperature 4..20 ma Accessories B90 attachment plate W90 console for wall mounting F90 protection filter sintered (for dust ambient) FG90 protection filter Goretex (for outdoor using) Accessories Protective basket F90 stainless steel sinter filter Protective basket FG90 gauze filter 6 pi-ma-humidity_e V1.00-00

GHM Messtechnik GmbH Sales Center International Schloßstraße 6 88453 Erolzheim Germany Fon +49-7354-937233-0 Fax -88 www.ghm-messtechnik.de info@ghm-messtechnik.de pi-ma-humidity_e V1.00-00 7

GHM Messtechnik GmbH Sales Center International Schloßstraße 6 88453 Erolzheim Germany Fon +49-7354-937233-0 Fax -88 www.ghm-messtechnik.de info@ghm-messtechnik.de Product Overview Laboratory Instrumentation Industrial Industrial Electronics Displays / Controller Transmitter / Signal conditioning Isolating converters Safety and Monitoring Devices Power Electronics Calibration and Testing Process Instrumentation Hygienic Design GHMadapt Temperature Flow Level / Filling Height Analysis Measuring Data Acquisition Data Logging and Monitoring Test Bench Measurement Technology Renewable Energies 8 pi-ma-humidity_e V1.00-00