Application Note. Monitoring Bearing Temperature with ProPAC

Similar documents
MAGPOWR Spyder-Plus-S1 Tension Control

DENISON HYDRAULICS open loop pump controls series P140 A-mod, P260 B-mod service information

AD592/592-10K Non-Room Units with a Junction Box, Weatherproof (WP) or Weather Tight (EU) Enclosure

SHORT-STOP. Electronic Motor Brake Type G. Instructions and Setup Manual

PFadvantage MF 6850/6855; Ideal 9080/9090

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

5001TCP SPEED CONTROLLER

mass flowmeter for compressed air

Combined Ventilation Controller RVWS-T-224HA

OD DIGITAL DISSOLVED OXYGEN CONTROLLER POLAROGRAPHIC CELL

LTX RF LEVEL SENSOR. Instruction Manual

TEGAM HTRHSERIES. High Temperature, Relative Humidity/ Temperature Probe Transmitter

BAPI-Stat 4 Room Humidity Sensor (BA/ B4 -H200 Series)

The Traveler Series: Adventurer

CPU-95EVS Enhanced VariSpark Digital Ignition System for Industrial Engines

T21 Thermal Differential Switch

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

BOILER BLOWDOWN CONDUCTIVITY CONTROLLER (CONTINUOUS METHOD)

Therm-L-Tec Building Systems LLC. Therm-L-Tech. Power Operated Retrofit Kit 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual

TX 115/215 Hot-tap Insertion Turbine Instructions

ZT-1 Tonnage Load Module By Toledo Integrated Systems User s Manual

GPS AutoSteer System Installation Manual

INSTRUCTION MANUAL 272-5X5 ANALOG TRANSMITTER (210 SERIES FLOW METERS) 272-5X7 ANALOG TRANSMITTER (220/240 SERIES FLOW METERS)

HSL-WI6 Ragsdale Bodymaker High Speed Logic Option User's Manual

5001TCP SPEED CONTROLLER

Power Operated Retrofit Kit for Manual Door 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual

H2B-ACDC H3B-ACDC H5B-ACDC. 1 Channel Current Sensor 2 Channel Current Sensor. 3 Channel Current Sensor 5 Channel Current Sensor

SERVICE SHOP NOTES. Use ohmmeter to check the resistance between the leads.

OD DISSOLVED OXYGEN METER

The Traveler Series TM : Adventurer

AD592/592-10K Non-Room Sensors in BAPI-Box, BAPI-Box 2 or BAPI-Box 4 BA/592-x-(BB, BB2, BB4) Temperature Sensor Instructions & Operation

INSTRUCTION MANUAL MODEL PS VDC POWER SUPPLY

M9216 Series Electric Spring Return Actuators

Furnace Web Site FAQs. Pro Press 100 / Pro 100 / Pro 100 plus. Lift. Belt Noise

FlowScanner 6000 SGIM-1 and SGIM-2 Strain Gauge Interfaces

12 Series Linear Actuators. Operation & Maintenance Manual, Analog Positioner Installation

1.0 Features and Description

MicroGuard 586 Retrofit Rated Capacity Indicator System. Calibration and Testing for:

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

WHEEL AND TIRE GROUP CONTENTS WHEEL AND TIRE DIAGNOSIS WHEEL AND TIRE SPECIFICATIONS ON-VEHICLE SERVICE...

GF1900 SULFURYL FLUORIDE MONITOR

Armstrong In-Line and Insertion Vortex Flow Meters

EM101 LOW FLOW MAGNETIC FLOWMETER INSTRUCTIONS

three different ways, so it is important to be aware of how flow is to be specified

DENISON HYDRAULICS Premier Series. open circuit pump controls P16 B-mod, P09 A-mod. service information

N I S T traceable calibration equipment conforms to MIL-STD-45662A.

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, or G)

150 PSI ILLUMINATED DASH PANEL GAUGE KIT

IP800-Series FLOW SENSOR INSTRUCTIONS IP810 IP :2008 ISO CERTIFIED COMPANY IP800-SERIES FLOW SENSOR INSTRUCTIONS

mass flowmeter for compressed air

Installation. Part A, Section 3. This section covers the following unit configurations: 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G)

OPERATIONS & INSTALLATION MANUAL

System 350 P352AB Electronic Pressure Control Series

OD OD DIGITAL DISSOLVED OXYGEN CONTROLLERS

INSTALLATION INSTRUCTIONS

PLEASE READ BEFORE CALLING OR RETURNING PRODUCT. EXTREMELY IMPORTANT!!!

INSTRUCTION MANUAL 276-5XX SERIES 4-20MA TRANSMITTERS

DW PADDLE-BELLOWS FLOWMETER & SWITCH

WHEEL AND TIRE GROUP CONTENTS WHEEL AND TIRE DIAGNOSIS WHEEL AND TIRE SPECIFICATIONS ON-VEHICLE SERVICE...

IP800-Series FLOW SENSOR INSTRUCTIONS IP810 IP :2008 ISO CERTIFIED COMPANY IP80-SERIES FLOW SENSOR INSTRUCTIONS

mygrid Installation Notes

INSTRUCTION MANUAL DIGITRAC % 2 DIGITAL TENSION READOUT AND CONTROL

IP80-Series FLOW SENSOR INSTRUCTIONS IP81 IP :2008 ISO CERTIFIED COMPANY IP80-SERIES FLOW SENSOR INSTRUCTIONS

TECHNICAL DOCUMENT EPC HORSEPOWER LIMITING

EZ-TRAC Digital Tension Readout and Control

General Information... Temperature/Resistance Table... Part Numbering Examples for RTD s. High Temperature MgO Elements (RA)...

PRSalpha Air Drill (Double Valve)

SLC-811X Series. Single Loop Proportional Temperature Controller General Instructions APPLICATION SPECIFICATIONS

WHEEL AND TYRE GROUP 31 CONTENTS ON-VEHICLE SERVICE GENERAL INFORMATION SERVICE SPECIFICATIONS TROUBLESHOOTING...

M-Tuned reroute kit XX

WHEEL AND TYRE GROUP CONTENTS WHEEL AND TYRE DIAGNOSIS WHEEL AND TYRE SPECIFICATIONS ON-VEHICLE SERVICE...

Installation. Part A, Section 3. This section covers the following unit configurations. Voltage 1, 2, 3. Vista Standard (V) A3EN-04-[3V-A-AAXV]-11

TABLE OF CONTENTS INTRODUCTION 3. INSTALLATION PROCEDURES Air Conditioner Location 4. A/C Ducting Installation 5

Stratomaster Maxi Single

CROWERGLIDE AUTOMATIC CLUTCH Instruction Manual

TX115/215 Hot-tap Insertion Turbine Instructions

GPS AutoSteer System Installation Manual

Wiring Assembly Instructions Section 5 P/N CASS P/N 1899AS RG316 P/N CASS P/N 1899AS RG316

Manifold QF. Contents. Description. Installation & Setup Guide. Safety 3. Introduction 3. Installation Standards 4. Specifications 5.

DENISON HYDRAULICS Premier Series. open loop pump controls series P080. service information

Hardware Installation. Tracer AH541 Version 2 Air-Handler Controller CNT-SVN02B-EN

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM

DW PADDLE-BELLOWS FLOWMETER & SWITCH

I N C O R P O R A T E D

TABLE OF CONTENTS INTRODUCTION.. 3. A/C Ducting Installation. Power Kit Installation (Batteries)...5 OPERATION MANUAL 7-8 TOOLS LIST..

DFC-1 STANDARD TEMPERATURE CONTROL. DFC-2 TEMPERATURE CONTROL w/ INTEGRAL 40 F-90 F SELECTOR DFTD TEMPERATURE SELECTION DIAL DFTS TEMPERATURE SENSOR

Instruction manual. Smart Thermal Mass Flow Meter. TYPE : 3000S Series. ientek Co., Ltd.

Basic 3-Stage Control Applications & Reference. RJG, Inc. 2002, 2003, 2009

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

WHEEL AND TIRE GROUP CONTENTS WHEEL AND TIRE DIAGNOSIS WHEEL AND TIRE SPECIFICATIONS ON-VEHICLE SERVICE...


Wheel Angle Sensor Kit Installation

User Manual. Liquid Level Sensor. Unit 600 Ampress Park Lymington, Hampshire SO4 l SLW United Kingdom

CO 2 Room Sensor in the BAPI-Stat Quantum Prime Style Enclosure

Model 930 Power Control System Instruction Manual

Gobius 1, Level Switch for Water, Fuel and Fluid Tanks, new version 5.0. Installation Guide. Before you begin

MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER

SPECIFICATIONS ATTENTION OPERATION DESCRIPTION

Purging Air From Divider Block Lubrication Systems

Transcription:

Monitoring Bearing Temperature with ProPAC Introduction A mechanical stamping press usually has two or more main bearings for supporting the crankshaft and for allowing smooth and accurate rotation. There may be other important bearings on your press, such as a flywheel shaft bearing. Proper lubrication along with periodic inspections to detect excessive wear along with verification of correct clearance is an essential part of every press s maintenance program. Monitoring bearing temperature when the press is running, especially under load is another way to reveal if a bearing is worn or about to fail. A number of factors can contribute to higher than normal bearing temperatures and resulting bearing failures. Some examples are age, lack of lubrication, incorrect ram parallelism, operating the press over capacity, improperly adjusted counterbalance pressure and worn-out dies. This application note will discuss how to measure and monitor bearing temperature using one or more RTDs (Resistance Temperature Detector), one or more Signal Conditioners and ProPAC (a SmartPAC module). Some basics about RTDs An RTD is a simple metal element formed of platinum, nickel, or a nickel-copper alloy known as Barco. It operates on the principle that metals increase in resistivity as temperatures increase and return to their original resistance upon cooling. When a small voltage is passed through the element, a voltage drop proportional to the element s resistance is converted into a temperature measurement or an output signal. RTDs are manufactured with a base resistance at some temperature point. This temperature is usually 0 o C (32 o F). The most common base resistance is 100 Ohms, which means that if the RTD is at 0 o C (32 o F), the resistance would be 100 Ohms. Application Note The nice thing about an RTD is the output signal does not need to be amplified. RTDs are available in many shapes, sizes and ranges for different applications. One popular type is in the shape of a stainless steel tube and is referred to as a probe (Figure 1). Figure1 - General Purpose RTD probe RTD probes are a good choice for measuring bearing temperature due to their length, shape and ability to be inserted into a hole and touch the outer race of the bearing. These probes are low in cost and are available in different lengths and diameters as an off-the-shelf item. Signal Conditioners Although the output of an RTD does not need amplification, there is still a need to convert the signal to something that can be interpreted by a controller. It is also necessary to supply the RTD with a constant excitation voltage. Fortunately, there are many off-the-shelf low cost modules available that accept a broad range of input signals (including RTDs) and deliver a variety of outputs including 0-10 Vdc 4-20 ma. Compact in size, most units will conveniently mount on a DIN rail (Figure 2) Wintriss Controls Group, LLC Page 1 2/1/2011

The probe is installed with the use of a Swagelok fitting. The fitting has a male pipe thread on one end and a compression fitting on the other. (Figure 3). Figure 2 Signal Conditioner mounted on DIN rail ProPAC ProPAC is a SmartPAC 1 or 2 module that can measure dimensions, angles and other part parameters in the die. In addition ProPAC can monitor process parameters such as bearing temperature. There are 8 (expandable to 16 or 32) analog sensor inputs that accept a 0-10 Vdc input. High and low control limits can be set manually or automatically with user-defined percentages. All limits are stored by tool. ProPAC can be programmed to either Top Stop or E-Stop the press if a limit is exceeded. Getting Started Choose the right RTD for your application and decide where and how it will be installed. If you plan on using a General Purpose Probe (Figure 1), it is important that the probe s tip makes solid contact with or is slightly embedded into the outer race of the bearing. Probes are typically available in sizes from 6 to 24 in length and 1/8, 3/16 or 1/4 in diameter. Unless there is an unusually long distance to reach the bearing race, the 6 long by 1/4 diameter probe should be fine. The number of wires or leads in the circuit is also an important consideration. A three-wire RTD is a good choice because it typically allows up to 36 of travel before being terminated. The third wire compensates for lead resistance by subtracting it from the circuit. Figure 3 Threaded male tubing fitting Suggested Supplier: Swagelok Swagelok P/N (2507-400-1-4) Find a flat area on the bearing cap that has enough thickness to accommodate the depth of the fitting. Calculate how deep a hole needs to be drilled in order to reach the outer race of the bearing. Drill and tap the appropriate size hole for the male end of the fitting. Drill another one, if necessary, centered inside it for the probe (Figure 4). The hole for the probe should be slightly larger than its diameter. Make sure the holes are clean before screwing in the fitting. It is also a good idea to use some Teflon tape around the threads first. Once the fitting is in place remove the threaded cap from the opposite end and slide the probe in until it makes solid contact with the bearing race (Figure 5). Do not tighten the end cap with the compression fitting at this time. You will need to remove the probe for calibration later in the instructions. Wintriss Controls Group, LLC Page 2 2/1/2011

RTD recommended specifications: 100 Ohm at 0 o C General Purpose Stainless Steel Probe with Strain Relief - 6 L x 1/4"Dia. (Note: length may vary for each application) 3 wire 36 length (Teflon -coated wire leads) Suggested Supplier: Omega Engineering Omega P/N (PR11-2-100-1/4-6-E) Figure 4 Outer hole drilled and tapped for Swagelok tubing fitting. Smaller inner hole counter bored for RTD probe Install Signal Conditioner in a location that is not more than 36 away from the RTD probe. It should be mounted on a short piece of DIN rail inside a small oil-tight enclosure (Figure 6) Figure 6 Signal Conditioner mounted inside oil- tight enclosure Note: It is OK to trim, but not extend the RTD s lead length. Doing so can cause the RTD to be inaccurate or malfunction. Follow the manufacturer s specifications. Figure 5 Probe inserted into Swagelok fitting. Probe tip touches race of bearing. The enclosure should also be large enough to accommodate three knockouts for 1/2 sealtight conduit. It is also advisable to install a power indicating panel lamp and a rated fuse (Note: run high voltage and low voltage wiring in separate conduits. This is to keep noise from interfering with the low voltage signals). Wire your Signal Conditioner according to your manufacturer s specifications. One (1) Signal Conditioner is required for each bearing mounted RTD. Wintriss Controls Group, LLC Page 3 2/1/2011

Signal Conditioner recommended specifications: 100 Ohm PT RTD Element 2 or 3 Wire Configuration 0 to 100 o C input range 0-10 Vdc output 0.2% Accuracy 1 ma Max Excitation Current 110 Vac powered DIN Rail Mountable Suggested Supplier: Omega Engineering Omega P/N (CCT-20-0/100C) Wiring the Signal Conditioner s output signal/s to your ProPAC s input/s is the last installation item to complete. Hopefully your ProPAC has an ample amount of unused analog inputs. If not, it can always be expanded from 8 inputs to 16 or 32 inputs (Contact Honeywell Wintriss or your Honeywell Wintriss Representative to learn more about ProPAC s input expandability). Choose an available ProPAC for each Signal Conditioner. Wire according to the wiring diagram in the back of your ProPAC User Manual and this Signal Conditioners Data Sheet / User Manual. Main Bearings Probe Tip Touching Outer Race Of Bearing 100 Ohm RTD Probe SmartPAC 1 or 2 Signal Conditioner 0-10 Vdc Output ProPAC Signal Conditioner 0-10 Vdc Output Block Diagram - Main Bearing Temperature Monitoring Wintriss Controls Group, LLC Page 4 2/1/2011

ProPAC (Process Monitor) Setup/Programming After completing the installation and wiring, it is time to set up and program the ProPAC. (Note: The example screens shown and the instructions used in this application example are for SmartPAC 2 and may vary slightly if you have a SmartPAC 1. For information about SmartPAC 1, consult your User Manual) Start out by accessing the Program Mode in SmartPAC. If you already have existing tools programmed, select one and choose the EDIT TOOL function key (Note: for creating new tools consult your User Manual). From the tool PROGRAM menu select PROCESS MONITOR and press the ENTER key. This will launch a list of 8 process monitor inputs (16 or 32 inputs if your ProPAC has been upgraded). Choose the input to which you wired the sensor and press the ENTER key. Next choose a name for the selected input. Fortunately, there are 4 selections for Bearing Temperature to select from. Select BEARING 1 TEMP for the first bearing, and press ENTER. Access the following screens, entering the values for each. SELECT THE UNITS FOR INPUT Enter either o C (Centigrade) or o F (Fahrenheit) (Note: For this application example o F will be used) SET THE RANGE /OFFSET OF THE SENSOR Enter the range of the RTD. In the first field next to Range, enter 0 o ; in the second field enter 330 o. Leave the POSITION OFFSET equal to 0. (Note: The value 330 o should be a good reference or starting point and can be checked for accuracy later in this discussion.) SET THE SENSOR OUTPUT VOLTAGE RANGE This is equal to 0 to10 Vdc and is the output coming from the Signal Conditioner. Enter 0 in the first field and 10 in the second field. If the Signal Conditioner has a different output voltage (for example 0-5 Vdc), enter that instead. Note: ProPAC will not work with 4-20 ma sensors. SELECT ACTION TO TAKE WHEN THE SENSOR EXCEEDS ITS SETPOINT LIMITS: Choose the appropriate stop condition. For bearing temperature monitoring, TOP STOP should be chosen. SET THE MEASUREMENT LOGIC Select: CONSTANTLY MONITORED THROUGHOUT THE STROKE. SELECT THE SETPOINT TYPE Select: MANUAL SETPOINT SET THE SETPOINT LIMIT The high setpoint is the highest allowable temperature the bearing can reach before the press is stopped (HIGH SETPOINT =). This value will most likely vary and as discussed earlier, exceeding it is dependent on a variety of conditions. Determining an accurate value may require some experimentation in order to evaluate optimal temperatures under different conditions. If you are not sure what to enter and do not feel comfortable about taking a guess, contact the press manufacturer for more information. The other two fields are LOW SETPOINT and REP (repeatable) SETPOINT. Unless you are worried about the bearing being too cool, leave these set to zero. Figure 7 is an example of how your programming may look. Once you have all your parameters entered, load the tool and access the Run Mode. Wintriss Controls Group, LLC Page 5 2/1/2011

(Note: If there is more than one bearing being monitored you must repeat this process for each. For example, if there are four bearings being monitored, each one will need its own input and programming and be aptly named either Bearing 1, 2, 3, or 4). Caution It is very important that ProPAC parameters for bearing temperature monitoring are the same for every tool in SmartPAC s memory (e.g. Figure 7). For SmartPAC 1 or 2, existing tools must be individually edited. For new tools, it is recommended that you use COPY TOOL (SmartPAC 1) or TOOL TEMPLATE (SmartPAC 2). This not only saves time, but ensures that the programming is always present in each tool (consult your SmartPAC manual for more details). Figure 7 SmartPAC 2 Program Screen Example - ProPAC Bearing Temperature Setup. Wintriss Controls Group, LLC Page 6 2/1/2011

SmartPAC with ProPAC (Process Monitor) Run Mode The last step is to verify that ProPAC is calibrated accurately with the RTD s actual output. To do this, access the Run Mode and select PROCESS MONITOR from the main menu. Then select Bearing 1 Temp from the list. Next, press the SENSOR CALIBRATION function key. This will access the screen shown in Figure 8. Notice that in this screen the top line is VALUE. This is the temperature being measured by the RTD. If the press hasn t been run in a while and the bearings are at room temperature, this reading should be equal to the temperature of the room. on the fitting until the probe feels tight and does not slide in or out. Running the Press and Viewing Bearing Temperatures Once your RTDs are installed and calibrated correctly and you are confident that all the equipment is wired correctly, you can start the main motor and run the press. To check bearing temperature while the press is running or idle, simply select PROCESS MONITOR from the main menu and select a bearing. A graph will appear displaying a flat line which represents bearing temperature throughout the stroke. If you need to make setpoint adjustments, press the ADJUST LIMITS function key. The simplest way to view actual temperature per stroke is in the Calibration Screen. (Note: HIGHEST VALUE and LOWEST VALUE are temperature measurement samples during each stroke of the press. For this application their significance is relatively unimportant.) Figure 8 - Run Mode Calibration Screen One way to verify the RTD s accuracy is to temporarily remove it from the bearing. Place the probe in a bowl of ice and water for several minutes. There should be more ice than water and the ice/water mixture should sit for about 5 minutes so it reaches the 32 o freezing point. If the voltage next to VALUE reads 32 o F, the calibration is correct. If it is reading incorrectly, adjust the RANGE until the reading is 32 o F. If there is more than one RTD, check the others the same way. Once all the RTDs are checked for accuracy, they can be permanently installed. Loosen the compression nut on the Swagelok fitting and slide the probe in until it makes solid contact with the bearing. Tighten the compression nut Wintriss Controls Group, LLC Page 7 2/1/2011