PANASONIC FAULT CODE GUIDE. ECOi ECO-G - PACi

Similar documents
LG Air Conditioning Universal & Multi Split Fault Codes Sheet. Universal and Multi Split Units

5. TROUBLE DIAGNOSIS

LG Air conditioning CAC and Multi Split unit Fault code sheet Universal and Multi Split Units

Fault Codes. J control

BRIVIS DUCTED INVERTER SERVICE MANUAL DRCi

Driftsinstruks. Utopia kontroller feilkoder PCP-2HTE og PC-ART. Vi håper de får stor glede av et Novema kulde produkt!

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU18RLXFW AOU24RLXFW ASU18RLF ASU24RLF R410A

SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE

PART7. Trouble Shooting

Fault Code Check List

No Operation of air conditioner Explanation

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models

9. Maintenance. 9.1 Precautions before Maintenance. Service Manual. electrolytic capacitor after power off. maintenance safely.

Service Manual. 9. Maintenance. 9.1 Precautions before Maintenance. discharge resistance or plug of soldering iron. Installation and Maintenance

6. Troubleshooting. 6-1 Basic items for trouble shooting. Samsung Electronics 17

OUTDOOR UNIT CONTROLLER (OUC)

ZIP Economizer Fault Detection and Diagnostics (FDD) Table

HEATER & AIR CONDITIONING CONTROL SYSTEM

QUARTZ INVERTER TROUBLESHOOTING GUIDE

A problem with the motor windings. A phase loss on mains terminals L1, L2, or L3 during run mode. Parameter 2-3 Current Imbalance Delay.

High Wall Type ( 2 Series )

Full list of fault codes and events

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

RAC Product Trouble Shooting Guide

troubleshooting Outdoor Unit: KSIE009-H221-O, KSIE012-H220-O, KSIE018-H220-O KSIE024-H220-O, KSIR036-H218, KSIR048-H218

Subject Underhood G System Error Codes and Symptoms System or Parts affected

LIGHT COMMERCIAL. Troublesooting

AC drive has detected too high a Check loading

DTC P0341 Camshaft Position (CMP) Sensor Performance

EcoNet and Flash Codes

CHILLER MANUAL. SAM JUNG ENC CO.,LTD.

Installation Diagram of Indoor Unit and Outdoor Unit /12K 18K 24K

Application Engineering Europe

CUMMINS ENGINE DIAGNOSTIC CODES

9. Maintenance. 9.1 Error Code List. Service Manual. Installation and Maintenance

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

User manual. Standard Modular Chiller HP 1/8 compressors with CAREL driver Application program for pco 1, pco 2, pco 3, pco C and pco XS.

KSID MINI Split DC Inverter QUICK CONNECT Air Conditioner TROUBLESHOOTING KSID016-H215Q. Model Numbers:

ProECU Subaru DIT. DTC List 2012-onward Model Year. v1.0

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

PRK PREVIEW. System. OZONE FRIENDLY R-407C Series. Inverter Heat Pump Series Heat Recovery Series PLUS Series (Heat Pump)

D M S 760 C01 A A 1 1

DTC P0102 Mass Air Flow (MAF) Sensor Circuit Low Frequency

Concealed Ducted Split Series R22

SMART DRIVE ELECTRONIC WASHING MACHINE

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Compact Wall Mounted Wall Mounted / Floor Compact Cassette / Slim Duct INVERTER MULTI

Designed for ease of integration with automation systems

technical data air conditioning systems MXS-B Multi Application Split Sky Air

DUCT type. SPLIT TYPE AIR CONDITIONER (50Hz) Models Indoor unit Outdoor unit C O N T E N T S

TECHNICAL HANDBOOK. for MULTISPLIT NETWORK SYSTEMS OR GROUP CONTROL

12. Troubleshooting Items to be checked first. Samsung Electronics

HAN-L62 MOUNTING PLATE

Submittal Data Information

Air Conditioner. Installation manual. Wired remote controller MWR-WE11N

SPLIT TYPE ROOM AIR CONDITIONER FLOOR TYPE

ceiling wall AWYZ14LB/18LB With the world's first self-cleaning filter system

AIR CONDITIONER 4 WAY CASSETTE SERIES. 1. Precautions. 2. Product Specifications. 3. Disassembly and Reassembly. 4.

C6 Corvette DIC Codes

SECONDARY PARAMETERS AND ENABLE CONDITIONS

AIR CONDITIONER 4 WAY CASSETTE SERIES. 1. Precautions. 2. Product Specifications. 3. Disassembly and Reassembly. 4. Troubleshooting. 5.

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2

To enter the diagnostic mode and check the existing error codes in memory, do the following:

Multi-Path RTU-TYPE 9 (RTU-1) CES-MPU-025-RE-VAV9

Engineering Data Book

DTC P0341 Camshaft Position (CMP) Sensor Performance

EvoX EFI ECU Pinouts Last Updated Tuesday, 24 April :40

PRODUCT LINEUP VRF For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL

Lotus Service Notes Section EMR

Lotus Service Notes Section EMD

Motor Protection With The MonitorPro

TRIPS AND FAULT FINDING

New ECOi Electric 2 and 3 pipe VRF systems. 2006/7 Range. All round air conditioning by

MCD 500 Service Manual. Functional Tests 5 Power Circuit Test 5 Start Performance Test 5 Run Performance Test 6 Trip Messages 6 General Faults 10

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

SPLIT TYPE AIR CONDITIONER. CASSETTE type. Models Indoor unit Outdoor unit MC24Y3E

EPAS Desktop Pro Software User Manual

BIGLA30-T/BIELA14-T Event Codes Quick Reference EXPLANATION CORRECTIVE ACTION PARTS TO CARRY ON SERVICE CALL

KMIR. Multi outdoor units. troubleshooting Multi zone CONDENSING UNITS MKMIR218-H221, KMIR327-H217, KMIR436-H217, KMIR545-H219.

4.Failure phenomenon. Mirage comes out from indoor. When the cold air from AC cools the indoor air. unit

LUV INVERTER SERIES. Self-diagnostics and Trouble-shooting. Part 2 of 2 42/38LUV028H 42/38LUV035H 42/38LUV052H 42/38LUV065H 42/38LUV070H 42/38LUV080H

Fuel Pump (FP ) Relay

ADJUSTABLE FREQUENCY CONTROLS SENSORLESS VECTOR CONTROL. Dual Rating. Technologies Inc. mgitech.com NRTL/C CERTIFIED

modular multi intelligent, environmental and versatile

Synchronous motor control. 8/15/2007 Powerflow Technologies Inc 1

Product Specifications

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

3. SERVICE TOOLS Inverter checker RSUK09-17 CLIMATE COMFORT. All Seasons. Heating. Air Conditioning. Applied Systems.

DIAGNOSTIC TROUBLE CODE DEFINITIONS

DRIVEABILITY - GAS. All symptoms listed above are diagnosed using the same tests. The title for the tests will be P0300-MULTIPLE CYLINDER MIS-FIRE.

2010 Touring Models - Electronic Diagnostic - Diagnostic Trouble Codes (DTC) 2010_DTC_Codes -.pdf

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

Diagnostic Trouble Codes (continued) Ford Specific Codes

SERVICE MANUAL Room Air Conditioner DC Inverter Multi Split Outdoor units

Delomatic 400 GAS CHP controller TCP/IP Modbus communication

Ion Technologies SUMPRO Battery Back-Up

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

Part 2 Functional Description

Models: 12 and 18. Models: 24 to 60

1. Unit selection (based on cooling load)

Transcription:

PANASONIC FAULT CODE GUIDE ECOi ECO-G - PACi

1 Page

INDEX P3 GHP ENGINE ISSUES P4 CENTRAL CONTROLLER ISSUES P5 ADDRESSING & COMMUNICATION PROBLEMS P6 SENSOR FAULTS P7 COMPRESSOR ISSUES P8 INCORRECT SETTINGS P9 INDOOR UNIT PROBLEMS P10 NOTES 2 Page

GHP ENGINE ISSUES A01 A02 A03 A04 A05 A06 A07 A08 A09 A10 A11 A12 A13 A14 A15 A16 A17 A19 A20 A21 A22 A23 A24 A25 A26 A27 A28 A29 A30 GHP - Engine oil pressure fault GHP - Engine oil level fault GHP - Engine over speed GHP - Engine under speed GHP - Ignition power supply failure GHP - Engine start up failure GHP - Fuel gas valve failure GHP - Engine stalled GHP - Engine overload GHP - High exhaust gas temp GHP - Engine oil level failure GHP - Throttle actuator fault GHP - Fuel gas valve adjustment failure GHP - Engine oil pressure sensor fault GHP - Starter power output short circuit GHP - Starter motor locked GHP - Starter current (CT) coil failed GHP - Wax Valve (3 Way) fault GHP - Cooling water temp high GHP - Cooling water level fault GHP - Cooling water pump fault GHP - Engine crank angle sensor failure GHP - Engine cam angle sensor failure GHP - Clutch fault GHP - Misfire GHP - Catalyst temperature fault GHP - Generator fault GHP - Converter fault GHP - Fuel gas pressure low 3 Page

CENTRAL CONTROLLER ISSUES C01 C02 C03 C04 C05 C06 C12 C16 C17 C18 C19 C20 C21 C22 C23 C24 C25 C26 C28 C29 C31 Duplicated setting of control address Central control number of units mis-matched Incorrect wiring of central control Incorrect connection of central control System Controller fault, error in transmitting comms signal, i/door or o/door unit not working, wiring fault System Controller fault, error in receiving comms signal, i/door or o/door unit not working, wiring fault, CN1 not connected correctly Batch alarm by local controller Transmission error from adaptor to unit Reception error to adaptor from unit Duplicate central address in adaptor Duplicate adaptor address Mix of PAC & GHP type units on adaptor Memory fault in adaptor Incorrect address setting in adaptor Host terminal software failure Host terminal hardware failure Host terminal processing failure Host terminal communication failure Reception error of S-DDC from host terminal Initialization failure of S-DDC Configuration change detected by adaptor 4 Page

ADDRESSING & COMMUNICATION PROBLEMS E01 E02 E03 E04 E05 E06 E07 E08 E09 E10 E11 E12 E13 E14 E15 E16 E17 E18 E20 E24 E25 E26 E29 E31 Remote control detecting error from indoor unit, Address not set/auto address failed. Check interconnecting wiring etc. Re-address system. Remote detecting error from indoor unit, Indoor unit detecting error from remote, Indoor seeing error from outdoor. Qty of i/d units connected are less than qty set. Check; all i/d units are ON, reset turn off all units wait 5min power up Indoor unit detecting error from outdoor unit, Error in sending comms signal Outdoor unit detecting error from indoor unit, Error in receiving comms signal Outdoor unit detecting error from indoor unit, Error in sending comms signal Incorrect setting indoor/controller, Indoor address duplicated Incorrect setting indoor/controller, Remote address duplicated or IR wireless controller not disabled Indoor unit detecting error from 'option' plug, Error in sending comms signal Indoor unit detecting error from 'option' plug, Error in receiving comms signal Auto addressing failed, Auto address connector CN100 shorted during auto addressing Indoor unit failed to send signal to remote controller Setting Failure, Duplication of master indoor units Auto addressing failed, Number of indoor units connected are less than number set Auto addressing failed, Number of indoor units connected are more than number set Group control wiring error, Main indoor unit not sending signal for sub indoor units Group control wiring error, Main indoor unit not receiving signal for sub indoor units Auto addressing failed, No indoor units connected Auto addressing failed, Error on sub outdoor unit Auto addressing failed, Error on outdoor unit address setting Auto addressing failed, Quantity of main and sub outdoor units do not correspond to the number set on main outdoor unit P.C.B. Auto addressing failed, Sub outdoor unit not receiving comms for main outdoor unit Between units, Comms failure with MDC, does E31 remain after power is re-instated? If so replace PCB. & power PCB 5 Page

SENSOR FAULTS F01 F02 F03 F04 F05 F06 F07 F08 F10 F11 F12 F13 F16 F17 F18 F20 F23 F24 F29 F30 F31 Indoor Heat Exch inlet temp sensor failure (E1) Indoor Heat Exch freeze temp sensor failure (E2) Indoor Heat Exch outlet temp sensor failure (E3) Outdoor Discharge temp sensor failure (TD) or (DISCH1) Outdoor Discharge temp sensor failure (DISCH2) Outdoor Heat Exch temp sensor failure (C1) or (EXG1) Outdoor Heat Exch temp sensor failure (C2) or (EXL1) Outdoor Air temp sensor failure (TO) Indoor inlet temp sensor failure Indoor outlet temp sensor failure Outdoor Intake sensor failure (TS) GHP - Cooling water temperature sensor failure Outdoor High pressure sensor failure GHP - Cooling water temperature sensor fault GHP - Exhaust gas temperature sensor fault GHP Clutch coil temperature fault Outdoor Heat Exch temp sensor failure (EXG2) Outdoor Heat Exch temp sensor failure (EXL2) Indoor EEPROM error Clock Function (RTC) fault Outdoor EEPROM error 6 Page

COMPRESSOR ISSUES H01 H02 H03 H05 H06 H07 H08 H11 H12 H13 H15 H27 H28 H31 Compressor Fault, Over current (Comp1) Compressor Fault, Locked rota current detected (Comp1) Compressor Fault, No current detected (Comp1) Compressor Fault, Discharge temp not detected (Comp1) Compressor Fault, Low Pressure trip Compressor Fault, Low oil level Compressor Fault, Oil sensor Fault (Comp1) Compressor Fault, Over current (Comp2) Compressor Fault, Locked rota current detected (Comp2) Compressor Fault, No current detected (Comp2) Compressor Fault, Discharge temp not detected (Comp2) Compressor Fault, Oil sensor fault (Comp2) Compressor Fault. Oil sensor (connection failure) Compressor Fault. IPM trip (IMP current on temperature) 7 Page

INCORRECT SETTINGS L01 L02 L03 L04 L05 L06 L07 L08 L09 L10 L11 L13 L15 L16 L17 L18 L19 L21 Setting Error, Indoor unit group setting error Setting Error, Indoor/outdoor unit type/model miss-matched Duplication of main indoor unit address in group control Duplication of outdoor unit system address 2 or more controllers have been set as 'priority' in one system - shown on controllers set as 'priority' 2 or more controllers have been set as 'priority' in one system - shown on controllers not set as 'priority' Group wiring connected on and indvidual indoor unit Indoor unit address/group not set Indoor unit capacity code not set Outdoor unit capacity code not set Group contol wiring incorrect Indoor unit type setting error, capacity Indoor unit paring fault Water heat exch unit setting failure Miss-match of outdoor unit with different refrigerant 4-way valve failure Water heat exch unit duplicated address Gas type setup failure 8 Page

INDOOR UNIT PROBLEMS P01 P02 P03 P04 P05 P09 P10 P11 P12 P14 P15 P16 P17 P18 P19 P20 P22 P26 P29 P30 P31 Indoor unit fault, Fan motor thermal overload Outdoor unit fault, Compressor motor thermal overload, over or under voltage Outdoor unit fault, Compressor discharge temperature too high (Comp1) over 111 degc. Low on ref gas, exp valve, pipework damage. Outdoor unit fault, High pressure trip Outdoor unit fault, Open phase on power supply. Check power on each phase, inverter pcb, control pcb Indoor unit fault, Ceiling panel incorrectly wired Indoor unit fault, Condensate float switch opened GHP - Water Heat exch low temp (frost protection) fault Indoor unit fault, Fan DC motor fault Input from leak detector (If fitted) Refrigerant loss, high discharge temp and EEV wide open and low compressor current draw. Outdoor unit fault, Open phase on compressor power supply Outdoor unit fault, Compressor discharge temperature too high (Comp2) over 111 degc. Low on ref gas, exp valve, pipework damage. Outdoor unit fault, By-pass valve failure Outdoor unit fault, 4 way valve failure, i/door temp rises in cooling or fulls in heating. Check wiring, coil, pcb output, valave operation. Ref gas, high temp/pressure fault, heat exch temp high C2, 55-60 degc, cooling over-load, sensor fault. Outdoor unit fan motor fault, fan blade jammed, check connections, does fan turn freely, motor resistance 30-40ohm on each pair, no fan fault, yes pcb fault. Outdoor unit fault, Compressor overcurrent - check winding resistance, Inverter failure - check internal resistance term HIC + & - to UVW 200-300Kohm or more Outdoor unit fault, Inverter circuit fault - Motor-current Detection Circuit (MDC) fault, check comp windings, sen- sors C1 & TS, if ok possible pcb failure. Indoor unit fault, System controller detected fault on sub indoor unit Simultaneous operation multi control fault, Group controller fault 9 Page

NOTES 10 Page

Panasonic Heating and Cooling Systems Panasonic Appliances Air Conditioning Europe (PAPAEU) Panasonic UK, a branch of Panasonic Marketing Europe GmbH Panasonic House, Willoughby Road Bracknell, Berks, RG12 8FP United Kingdom Office: +44 (0) 1344 853 3393 Fax: +44 (0) 1344 85 3021 Web: www.aircon.panasonic.co.uk Panasonic PRO Club The Panasonic PRO Club is Panasonic s dedicated professional heating and cooling website. Signup at www.panasonicproclub.com for access to a wealth of information, tools service manuals and more. PANASONIC reserves the right to make any variation in specification to the equipment described or to withdraw or replace products without prior notification or public announcement. All descriptions, illustrations, drawings and specifications in this publication are given in good faith, but are intended to present only general particulars and shall not form any part of the contract. For full installation details, please contact your PANASONIC distributor. Rating Conditions The cooling and heating capacities are based on the following conditions: Cooling: Indoor temperature 27 C DB/19 C WB, Outdoor temperature 35 C DB/24 C WB. Heating: Indoor temperature 20 C DB, Outdoor Temperature 7 C DB 6 C WB.