Fluid Waste Handling System Mechanical

Similar documents
Product Guide: Series III Pump Control Board Set (RoHS)

Installation Instructions

TECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER

SERVICE MANUAL (DOMESTIC & INTERNATIONAL)

Installation Instructions

INSTALLATION INSTRUCTIONS

PARTS & SERVICE MANUAL

Spray Height Controller

Model No. DFC-X Support DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Unit 5 Troubleshooting

Service Manual. Extractor Model XR28QP. For The. For: Troubleshooting Adjustments

ELECTRICAL. Contents - Wiring Diagrams

WARNING This manual should only be used by a qualified Service Technician. FinishPro 390/395 Airless/Air-Assisted Sprayer Repair Electrical Manual

CENTROIDTM. AC Brushless Drive. Product Spec Sheet

To ensure proper installation, digital pictures with contact information to before startup.

USERS GUIDE LO-21U LOCKOUT RELAY

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

TROUBLESHOOTING GUIDE FOR HEAT PUMP BOOSTERS MODELS: HPB11, HPB15, & HPB22

PACIFIC Recumbent Height-Adjustable Bath System Parts Breakdown and Assembly Manual

DFC-1 STANDARD TEMPERATURE CONTROL. DFC-2 TEMPERATURE CONTROL w/ INTEGRAL 40 F-90 F SELECTOR DFTD TEMPERATURE SELECTION DIAL DFTS TEMPERATURE SENSOR

Wiring diagrams on page 29 are for reference only. For detailed vehicle wiring refer to Navistar documents.

Automotive Application ET01 Software Revision A 12/06

348002K/348012K Manifold Block Style Service Manual 12/2000

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

Idle Free Systems, Inc. Reference Guide System Component Information

Just what is an alternator?

OnCommand Troubleshooting Guide Hayward Industries

C.E. Niehoff & Co. C703/C703A and C706 Alternators Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING.

Explanation 1 Input External Switch 2 Input Hipot Safety Switch

INDEX Section Page Number Remarks

3 Phase Smart Controller

AQUASTAR C6. (Comfort 6000) Next Generation Auto Backwash Valve System. (selectable time-pressure or remote cycle start)

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

DIAGNOSTIC TROUBLESHOOTING INDEX

TC62D Installation Instructions

AUTO CHARGE 4000 MODEL #: LOW PROFILE CHARGER AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

Trima Accel Automated Blood Collection System. Service Manual

Mustang. Installation Manual. Revision 11/16/10

C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

To ensure proper installation, digital pictures with contact information to before startup.

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator.

Q&A FOR Webinar on Electrical Basics & Boiler Wiring

3 in 1 TRAIL CHARGER with LOCKOUT

Alarms & Remote Start

INSTALLATION INSTRUCTIONS. Revision 3.1.1

BIGLA30-T/BIELA14-T Event Codes Quick Reference EXPLANATION CORRECTIVE ACTION PARTS TO CARRY ON SERVICE CALL

The ignition coil for the vehicles covered by this guide is in the following locations:

Sprayer Control. Manual for SprayLink Cable Installations. Tank. Jet Agitator. Agitator Valve. Diaphragm Pump. Pressure Transducer.

Sentry Battery Charger. Installation and Operations Manual Section 75

Arch HTH Water Chemicals Commercial Equipment Trouble Shooting Guide

1100 Series Piston Type Differential Pressure Gauges

Types and 52.20, Specialized test procedure Milk receiving and milk pick-up metering systems

Error codes Diagnostic plug Read-out Reset Signal Error codes

Elite Power Solutions Automatic Battery Control (ABC) Operation Manual

Troubleshooting Bosch Proportional Valves

Congratulations PRE-OPERATION SETUP

BRIVIS DUCTED INVERTER SERVICE MANUAL DRCi

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

Overview of operation modes

AQUIS Foam System. Installation, Operation, and Maintenance Instructions AQUIS 1.5, AQUIS 3.0, and AQUIS 6.0

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2015 CLOVER SYSTEMS All Rights Reserved

MPA Chassis for Multi-Probe Magnetic Transducers

Auto-Level Troubleshooting (Old Platform) Electronic Control- Prior to 2009, Pressure Switch Control panel #s 2057, 2058, 2795, 2795B

Troubleshooting 3Z8 038 Rev B

Error code explanation Diagnostics...2 Error Code Chart...3 Tests Wiring diagram...6

G3 PRIMO CAPPUCCINO SYSTEMS

Troubleshooting. This section outlines procedures for troubleshooting problems with the operation of the system:

SCHNITZ MOTORSPORTS USER MANUAL AND INSTALLATION GUIDE PRO-MOD BATTERY VOLTS DIAGNOSTICS NOS PULSE FREQUENCY NOS DELAY TIME IN SECONDS

Electronic Service Manuals

INSTALLATION & OPERATION MANUAL

Alarms & Remote Start

E.S.P. Embedded Sensing Probes for Motor Brushes

TROUBLESHOOTING TP. Index

ALWAYS DISCONNECT DISPENSER FROM WATER SOURCE WHEN DISPENSER IS NOT IN USE.

POWERLINE 2000 Energy Management System TM

AUTO CHARGE D PUMP PLUS

Driver Board User Manual

VFC-5 to VFC-500 FLO-COATER

INSTALLATION INSTRUCTIONS

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Idle Air Control (IAC) System Diagnosis

MANUAL TROUBLESHOOTING. ECM Motor. ECM / ECM-DX Series. v100 Issue Date: 08/15/ Price Industries Limited. All rights reserved.

KenkoAir_Purifier manual ENG-FR_FDA 10/12_Air Filter manual 8/15/13 10:44 AM Page 1 OPERATING MANUAL

TERMINATOR User Manual

To Purchase This Item, Visit BMI Gaming

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320


5001TCP SPEED CONTROLLER

Fault Code 34 - Weak Battery Voltage Supply

AUTO CHARGE 4000 MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

GTFM IV. Operation / Installation Manual. Gas Turbine Flow Monitor. Computer Weld Technology, Inc. Manual Part Number: A8M5010 Revised: June 26, 2008

REC-11+ REMOTE RECEIVER UNIT

4.0L CEC SYSTEM Jeep Cherokee DESCRIPTION OPERATION FUEL CONTROL DATA SENSORS & SWITCHES

BOSS 107 SEPARATOR SYSTEM INSTALLATION & APPLICATION MANUAL

GENERAL <ELECTRICAL>

install guide OEM-CH(RS)-CH5-[FLRSCH5]-EN

SERVICE MANUAL (INTERNATIONAL)

Troubleshooting Guide

Transcription:

Fluid Waste Handling System Fluid Waste collected through Manifold Drain Valve Fluid Waste System Theory of Operation At the Docking Station, fluid waste is removed from the Rover s s and discarded into the hospitals waste water system. This docking process proceeds automatically when the Rover is pushed into the Docking Station. The general fluid waste transfer steps involved are: The Docking Station connects to the dry break Waste Coupling on the bottom of the Rover Waste Fluid is pulled from the Large and discarded by the Docker s Offload Waste Fluid from the Small is dumped into the Large by opening the Drain Valve The Offload continues running until all waste is removed s are washed and related water is offloaded in the same manner Drain Valve The Drain Valve between s is a motor actuated Ball Valve connected to a motor control circuit. Its position (open/ closed) is determined by a hall sensor mounted to the front of the motor. Small Clogging During the docking cycle, clotted blood may not drain from the Small to the Large by the force of gravity alone. To increase the effectiveness of the offload process, the Large is sealed as the Small is drained. This allows the Offload to draw a vacuum (up to ~ inhg) on the Large. This vacuum, in addition to the force of gravity, pulls clotted blood from the Small through the Drain Valve. Fluid Waste pumped to hospital waste water system Soap Offload Waste Coupling extends from Docker to mate with Rover Fluid Waste Subsystem00SREA

Fresh Water Handling System Fresh Water System Theory of Operation Spray Ball in each At the Docking Station, the Rover s are washed using the normal hospital water supply pressure. Cleaning water is transfer from the Docking Station to the Rover via dry break couplings. The flow of water within the system is controlled by a Water Solenoid Valve in the Docking Station. The water s destination (Small or Large ) is controlled by the Diverter Valve (two solenoid valves) located in the Rover. Prefill To enable fluid volume measurement, both s require a small amount of clean water be added after they are offloaded. This prefill water also includes a small amount of detergent to aid in cleaning during the next docking cycle. At the Docking Station, prefill water is added through the spray ball in each Fresh water in from hospital water supply Detergent drawn from external bottle Prefill The Small can be emptied into the Large away from the Docking Station. This allows the user to fill the Small multiple times before returning to the Docking Station (i.e. multiple surgical uses between docking cycles). To prefill the small canister away from the Docking Station, the Rover utilizes water sto in its internal Prefill Tank. Water is pulled from the Prefill Tank by the Prefill and added to the Small. Note that the plumbing configuration within the Rover ensures that the Prefill Tank is filled automatically during Docking. Detergent Dispensing Detergent is mixed with rinse water inside the Docking Station to improve cleaning. Detergent is dispensed by the Soap at specific points during the docking cycle to maximize cleaning effectiveness. Water Temperature and Pressure Water temperature and the flow rate can significantly affect the ability of the system to clean itself. Since the system does not control either of these parameters, it is important that the hospital plumbing be set up according the the system s installation instructions. Warm water, up to 0 F, provides the best cleaning. Temperatures above this can cook the blood in the system causing offload problems. High temperatures can also damage internal plumbing components. Low temperatures tend to be less effective at removing fats. Prefill Tank Prefill Tank Solenoid Valve Sequencing To prevent trapping high pressure water in the Rover and Docker Couplings, the solenoid valves are automatically opened and closed in a specific sequence. When turning the water on, the proper Diverter Valve is opened first, followed by the Docker Solenoid. When turning the water off, the Docker Solenoid is closed first, followed by the Diverter Valve. Water Solenoid Valve When extending or retracting Couplings, the Diverter Valve is opened to prevent pressure in the Couplings from stalling the Coupling Actuator in the Docking Station. Backflow Prevention Check Valve Soap Offload Diverter Valve directs water to either the Small or Large Water Coupling extends from Docker to mate with Rover Fresh Water Subsystem000SREA

Level Sensor System Level Sensor electronics Sensor Float (magnetic) Volume Display Level Sensor Theory of Operation In the Operating Room, the Rover monitors and displays the fluid level of each to the user. Fluid levels are also used to ensure the docking cycle is carried out correctly. The Level Sensing system is comprised of a Level Sensor Rod, two magnetic Sensor Floats, and two Reference Magnets attached to the bottom of the s. To make a volume measurement, an electrical current Interrogation is sent from the Level Sensor electronics down a wire inside the Level Sensor Rod. When this current pulse passes by each of the four magnets, a mechanical Return is sent back up the Level Sensor Rod. The time between return pulses is used to determine the distance between each s Sensor Float and Reference Magnet. This time is used to calculate the fluid volume. See the timing diagram below for a visual description of this process. Calibration Manufacturing variation between s (i.e. canister shape, reference magnet position, etc.) is addressed by factory calibration of each one produced. A s calibration information is sto in a permanently attached Calibration PCBA. This calibration information is read by the Rover s Main ler at every power up, preventing the need for field calibration when canisters are replaced. Float Calibration Manufacturing variation between Floats (i.e. float weight, internal magnet placement, etc.) must be addressed by field calibration. An especially heavy Sensor Float would sit lower in the canister fluid than a light one. This would result in a different FloatReference magnet distance for a given fluid volume. The Float Calibration Procedure must be performed any time a Rover s floats are changed. Float calibration information is sto on the Rover Main ler PCBA. Consequently, the F Float Calibration Procedure must be repeated when this PCBA is replaced. Reference Magnet attached to Calibration PCBAs Since the time between return pulses is not dependent on which sensor is used, the Float Calibration Procedure does not need to be repeated when the Level Sensor Rod is replaced. Temperature The diameters of the Fluid Collection s increase or decrease with temperature due to thermal expansion. Because fluid volume calculations take this geometry change into account, the Calibration PCBA s also include sensors to measure temperature. Sensor Float (magnetic) Interrogation Sent Return from Small Float Return from Small Reference Magnet Large return pulses Distance between magnets corresponds to fluid volume V Reference Magnet attached to Time (microseconds) Time between pulses corresponds to distance between Float and Reference Magnet Level Sensor Subsystem00SREA

Evacuation System Evacuator Theory of Operation The Rover s Evacuation system is activated by pressing a button on the User Interface Panel. The Blower speed can also be selected to offer the right tradeoff between noise and smoke evacuation effectiveness. Air containing smoke is evacuated from the surgical site and filte before being discharged back to the room. The Filter removes smoke particulate using ULPA rated filter media and captures other volatile chemicals with an activated carbon bed. Manual Mode When operated in Manual Mode, the Evacuator Blower runs at a constant speed regardless of the level of smoke present in the OR air. Auto Mode A Sensor is built into the ULPA filter for identifying when smoke is actually being generated at the surgical site. When placed in Auto Mode, the Evacuator Blower defaults to a low speed to sniff for smoke. This sniffing speed was selected to minimize the Blower s audible noise. Sensor included in ULPA Filter If a smoke plume is generated, it is drawn into the ULPA filter and detected by the Sensor. The Blower speed is immediately increased to more effectively evacuate the plume. When smoke is no longer detected, the Blower returns to sniffing speed until additional smoke is generated. collected through filter inlet Evacuator ULPA Filter Evacuator Blower Filte Air exhausted inside Rover Blower Speed Circuitry controlling the Blower is designed to ensure its speed is constant over the expected ranges of mains line frequency and voltage. The Rover determines the line frequency (0/0 Hz) at power up and continuously monitors and reacts to line voltage changes while running. Cooling Air If run with all of the ULPA Filter inlets closed, the Evacuator Blower requires cooling air to prevent overheating. This air is provided by a restrictive porous plastic inlet located inside the Rover. Cooling Air Inlet Evacuator Subsystem000SREA

System Theory of Operation The onboard vacuum system is activated by a button on the User Interface and vacuum settings are selected for each canister through dedicated dials. While there is only one in the Rover, the actual vacuum level in each canister is controlled by two separate Valves. Each Valve attempts to maintain its canister at the user selected vacuum setting by: connecting the to the vacuum source ( ) to increase it s vacuum level connecting the to the atmosphere to decrease (vent) it s vacuum level sealing the to maintain it s current level of vacuum See the diagrams below for a visual explanation of regulator function. Overflow Prevention Float and Mist Collection Foam Valve position is controlled by a DC driven by a circuit. Valve position is determined by an optical mounted to each. Since the does not provide absolute position information, an initialization sequence is performed each time the Rover is powe on. This sequence involves driving the in each direction until a hardstop is reached. Fluid Waste collected through Manifold Air removed from to create vacuum Measurement The actual vacuum level of each is monito by PCB mounted Sensors. Each is monito by a Primary and Secondary Sensor. The readings from Primary and Secondary Sensors are constantly being compa to each other to ensure accuracy and detect Sensor failure. House Suction The user also has the option of providing suction to the s via the hospital s wall suction. For this mode of use, the s do not attempt to control the s vacuum level. The Rover must be turned on, however, to ensure the s are in a position that will allow house suction to work (i.e. not vented to atmosphere). Check Valves in the House Suction Ports eliminate the need for capping these ports when not in use. Additional Check Valves at the inlet to the HEPA filter prevent air from being drawn backward through the when House Suction is used Docking s are also used during docking to vent or seal s. This facilitates offloading waste and prevents building pressure while spraying rinse water. Distribution PCBA Relief Valve allows cooling air for Fluid Suction HEPA House Suction Ports with internal Check Valves Actual below Set Point Fluid Collection Actual Secondary Sensor Primary Sensor lers Muffler Check Valves To or House Suction Actuated Valve Atmosphere Vent Valve Position Actual at Set Point Fluid Collection Actual above Set Point Fluid Collection To or House Suction Atmosphere Vent To or House Suction Atmosphere Vent Actuated Valve Actuated Valve Subsystem000SREA

Coupling and Actuation System Docker Electrical Movable Coupling Plate Water and Waste Couplings Lead Screw Coupler Stepper Docker Coupling Actuator Theory of Operation During docking, fluid connections are bade between the Rover and Docker to transfer fluid waste and fresh water for cleaning. The Water and Waste Couplings on the Rover are stationary and mounted to the bottom surface. In the Docking Station, they are mounted to a movable plate. This plate is raised and lowe by a Stepper riding up and down a stationary lead screw. Diagrams to the left illustrate the components involved, showing them in the fully extended and retracted positions.. Coupling position is determined using two digital hall sensors. The Extended Hall Sensor is trigge by a metal Sensor Flag when the couplings are fully extended. The Retracted Hall Sensor is trigge by the Flag when the couplings are fully retracted. The entire coupling mechanism is floated on springs to accommodate misalignment between the Rover and Docking Station. Coupler An inductive Coupler transfers power wirelessly from the Docking Station to the Rover during Docking. The Coupler functions much like a transformer with a primary winding located in the Docking Station and a secondary winding in the Rover. The two transformer halves are brought together when the Rover is pushed into the Docking Station, which allows for power transfer. Extended Hall Sensor Sensor Flag Springs to float Coupling Mechanism Retracted Hall Sensor Couplings shown retracted Couplings shown extended Soap Offload Coupling mechanism shown in detail above Coupling Actuation Subsystem00SREA

IV Pole System Moving IV Pole IV Pole Theory of Operation Stationary (outer) IV Pole The Rover s IV Pole is raised and lowe in response to buttons pressed on the User Interface Panel. The Pole is driven by a DC motor and associated control circuitry. The contains an integral Brake, which when powe, holds the Pole at the desi height. The mechanism connecting the IV Pole to the IV Pole is illustrated in the diagram below. Auto Down Feature When power is removed from the Rover, the IV Pole Brake releases automatically. As the pole begins to drop under its own weight (and the force of an internal Return Spring), the is mechanically backdriven by the falling Pole. In this instance, the acts as electrical generator and provides power to run a speed control circuit. The speed control circuit electronically brakes the to limit the speed of the descending Pole. Since the speed of Pole descent is controlled by the, if it is electrically disconnected from the rest of the system, the Pole will fall rapidly. Idler Pulley at top of stationary Pole Support Stationary Pole Support Moving IV Pole Moving Pole attached to Belt IV Pole with integral Brake drives this Pulley, moving Belt to raise or lower IV Pole Integral Brake on holds Pole at desi height IV Pole Subsystem000SREA

in from Mains Switch / CB in from Docker /yellow EMC Filter Coupler Coil Note Rover Coupler PCBA 00000 J AC PCBA 00000 J J VAC VAC Note 0 or 0 VAC 0 or 0 VAC F (0VAC selector) F (0VAC selector) VDC F (. A) / Speed 0 VAC 0 VAC J 0 F (0 A) Note Note 0 VAC 0 VAC 0 VAC 0 VAC Vac 0/0 Hz Detect Vac Sp Setting VDC J J J J violet violet Auto Xfmr 00000 Primary 0 VAC. VAC. VAC Secondary Note Assy Blower Cooling Fan Cooling Fan Component Resistance Chart: Blower Cooling Fans Prefill Small Large Component Winding Resistance (Ohms) 0 0 0 0 See Note IV Pole 0 IV Pole Brake 0 Small Diverter Large Diverter Drain Valve 0 Coupler Coil 0. Important General Diagram Notes: PRODUCT MALFUNCTI IS OFTEN DUE TO DAMAGED ELECTRICAL CNECTORS. TAKE CARE NOT TO DAMAGE CNECTOR PINS WITH METER PROBES! CHECKING RESISTANCES AT THE AC POWER AND PD PCBA EDGE CNECTORS VERIFIES CTINUITY OF WE HARNESS AND INTERNAL COMPENT WINDINGS. THIS IS THE PREFERRED LOCATI TO BEGIN TROUBLESHOOTING. Resistance and voltage values given are not specifications, but general expected values. These should be used primarily for determining continuity or basic circuit function. Resistance measurements must be made with rover power off and control circuitry disconnected to avoid damage / false readings. All voltage measurements (other than transformer primary and secondary) must be taken with component plugged in to avoid false readings. Needle type probes will be requi to contact conductors inside mated connectors. Digital communication connections are indicated with dotted lines., ground, and analog signal connections are indicated with solid lines. Specific Diagram Notes:. Brush motor resistance as measu with a volt meter can vary dramatically based on brush contact with the motor.. Resistance shown is the value if checked at the prefill pump with connector removed. A diode in the wire harness prevents continuity checks at J0 of Distribution PCBA. To check continuity there, set meter to DIODE MODE. Attach positive lead to pin and negative lead to pin of the wire harness. Diode drop measu should be ~ 0. VDC. Switch leads and ensure meter reads OL.. Voltage applied to smoke blower motor depends on speed setting. It will be 0 VAC with smoke blower off. The speed setting is communicated from Distribution PCBA to AC PCBA.. Cannot measure voltage at pump due to connector design.. Component is speed controlled, so applied voltage will vary rapidly. Volt meter measurements are not possible.. can be checked via technician menu (TECHNICIAN MENU \ VACUUM \ REGULATOR). It is shown as "PSVOLT". Its value depends on the power source and should be ~ VDC when powe by the Docker and 0 VDC when powe by mains.. Logic Pwr depends on the power source and should be in the range of 0 VDC. and Logic Pwr are the same voltage when docking.. High frequency / high voltage signal cannot be measu with volt meter.. Actual voltage measu at component will be volts lower than. 0. signals are combined with an AND gate on the AC board.. The voltage supplied by mains may be either 0 VAC (0 Hz) or 0 VAC (0 Hz). Fuses F and F on the AC PCBA are used to select which is provided. The autotransformer produces 0 VAC on its primary if 0 VAC is supplied. It produces 0 VAC on its primary if 0 VAC is supplied.. This voltage is electrically isolated from other voltages in the system. It must be measu using pin as the ground reference.. Transformer voltages shown are for the fully loaded condition. Unloaded voltages will be VAC higher. Data from/to Docker Radio PCBA 0000 S/N PCBA 0000 J Rover Main ler PCBA 000000 J Main Display N/C J 0 VDC VDC VDC VDC to Docker to Docker from Docker from Docker J from Docker from Docker Rover Main ler Reset to Docker to Docker Note J J Logic Pwr VDC Reset J Distribution PCBA 00000 J Logic Pwr VDC Note Reset Speed VDC Position Sensing 0 VDC Note VDC J0 Note. VAC. VAC Speed J0. VAC Note. VAC J0 0 VAC 0 VAC J0 Note Note Speed VDC Vac Sp Setting Logic Pwr 0 Vac 0/0 Hz Detect Position Sensing J Note Note 0 Note DC/DC Converter Note Speed VDC VDC VDC Sensing Position Sensing Calibration Reading Position Sensing Note 0 VAC 0 VAC VDC J0 VDC VDC Isolated (ID) (ID) 0 J J J 0 J violet J Prefill Sensor (in ULPA Filter) Level Sensor Small Calibration PCBA 00000 Note J (ID) (ID) Large Calibration PCBA 00000 J 0 J J J J J 0 J J 0 J J Edge Connectors and pin counting for Distribution and AC PCBA s Volume Display PCBA 0000 VDC Reset J yellow yellow J J J 0 J0 J J 0 J J Volume Display Drain Valve Position Sensor Large Diverter Small Diverter IV Pole IV Pole Brake Small Small Large Large This drawing shows sheet metal mounted connectors, viewed from the back of the rover with circuit boards removed. System Wiring Diagrams00SREA

Docker Main ler Map: Wi for 0 VAC mains Hardware LED Indicators: (See Note 0) Docker Isolation Xfmr 0000 Docker Main ler Software Status LEDs: (See Notes, ) Questra ler Software Status LEDs: (See Notes, ). VAC System Condition / Defect Switch / CB VAC Primary Coupling Door D Door Closed OFF 0 VDC Couplings Extended D0 Extended Expected Couplings Retracted D Retracted LED Label (no ethernet connection) (with ethernet connection) OFF D OFF OFF D (dim) FLASH (0s / 0s) FLASH (0.s / 0.s) D0 D D FLASH LED 0 VAC 0 VAC Secondary (D) Questra ler (D0) Software Status LEDs (D) 00000 Revision Level Retracted LED (D) Extended LED (D0) H = Offload State D = Water Solenoid State D = Electromagnet State D VAC Primary AF D Switch / CB LED Label Soap State = OFF Extend/Retract Test Buttons = Component Winding Resistance (Ohms) 0 VAC if Trigge Docker Main ler PCBA Revision Level Component Resistance Chart:. VAC Expected D Secondary LED State if Trigge Docker Isolation Xfmr 0000 Note System Condition Expected 0 VAC Trigge Condition LED LED Label 0 VAC 0 VAC from Mains Coupler Questra Com PCBA Com Lost Lost 0 VAC from Mains 0 VAC LED Label Electromagnets Coupler Coil <.0 J See Note Soap 0 Water Solenoid 0 Offload N/A Actuator Stepper Docker (D) Main ler (D) Software Status (D) LEDs J0 J Coupling Door LED (D) J J Note N/C Data from/to Rover Water Solenoid LED (D) D D D D J D0 F F (A) (A) Coupler Driver Actuator Stepper 0 VAC Couplings Extended Hall Sensor J 0 VAC Couplings Retracted Hall Sensor Note Coupling Door Hall Sensor J 0 VAC 0 VAC purple 0 VAC / J 0 VAC / / / / / J0 0 purple yellow VDC J0 GND VDC VAC VAC Coupler Coil out to Rover Specific Diagram Notes (continued): PRODUCT MALFUNCTI IS OFTEN DUE TO DAMAGED ELECTRICAL CNECTORS. TAKE CARE NOT TO DAMAGE CNECTOR PINS WITH METER PROBES! BOTH THE DOCKER MAIN CTROLLER AND POWER COUPLER PCBA S HAVE LARGE CAPACITORS THAT RETAIN CHARGE FOR EXTENDED PERIODS OF TIME. POWER MUST BE REMOVED FROM THE DOCKER FOR MINUTES PRIOR TO CNECTING OR DISCNECTING ANYTHING FROM THESE PCBA S!. The voltage supplied by mains may be either 0 VAC (0 Hz) or 0 VAC (0 Hz). Input voltage is selected by installing the appropriate wire harness P/N between the power switch and transformer. The main diagram shows the Docker wi for 0 VAC mains. Electromagnet CHECKING RESISTANCES AT THE CNECTORS TO THE DOCKER CTROLLER PCBA VERIFIES CTINUITY OF WE HARNESS AND INTERNAL COMPENT WINDINGS. THIS IS THE PREFERRED LOCATI TO BEGIN TROUBLESHOOTING. Electromagnet Resistance and voltage values given are not specifications, but general expected values. These should be used primarily for determining continuity or basic circuit function. Resistance measurements must be made with docker power off and control circuitry disconnected (unplug wire harness from PCBA) to avoid damage / false readings. All voltage measurements (other than transformer primary and secondary) must be taken with component plugged in to avoid false readings. Needle type probes will be requi to contact conductors inside mated connectors. Digital communication connections are indicated with dotted lines., ground, and analog signal connections are indicated with solid lines.. The resistance of both stepper motor phases should be checked. Check resistance from wire to /. Check resistance from wire to /. 0. Hall signal indicator LED s are when hall sensors are unplugged.. The software status LED states specified in this table apply after the Docker power up sequence is complete and when no Rover is attached. The Docker power up sequence is complete 0 seconds after power is applied.. Questra Com Lost condition requires replacing Docker ler PCBA. Coupler Com Lost condition requires troubleshooting of Coupler PCBA (check for power and continuity of communication lines).. Conditions other than those shown may require replacing Docker ler PCBA.. Fuse and fuse holder was not included in PCBA revisions prior to H.. Transformer voltages shown are for the fully loaded condition. Unloaded voltages will be VAC higher. Specific Diagram Notes: Note VDC J0 Important General Diagram Notes: Note Note 0 Note 0 F Coupling Test Buttons J Electromagnet LED (D) Note J D Stepper D D J J 0 J pink Offload LED (D) Questra ler Soap LED (D) D J Docker Main ler N/C D VDC D VDC yellow D0 D VDC VDC J 0 Note purple tan to Rover to Rover from Rover from Rover VDC DC/DC Converter Logic Pwr Note to Rover to Rover from Rover from Rover VDC S/N PCBA 0000 Docker Coupler PCBA 0000 J J N/C VAC N/C 0 VAC. VAC VAC. VAC 0 VAC Docker Main ler PCBA 00000 J. The offload pump has an internal rectifier that prevents making resistance measurements. To check continuity, put meter in DIODE MODE. Measu voltage drop through the pump should be ~. VDC when checked in both directions.. Resistance shown is the value if checked at the prefill pump with connector removed. A diode in the wire harness prevents continuity checks at the Main ler end of the wire harness. To check continuity there, set meter to DIODE MODE and remove connector from J of the PCBA. Attach positive lead to purple wire and negative lead to wire. Diode drop measu should be ~0. VDC. Switch leads and ensure meter reads OL.. Cannot measure voltage at pump due to connector design. Voltage can be measu at Docker ler PCBA. With pump off, measu voltage will be < 00 VAC. With pump on, measu voltage will be ~0 VAC.. Component is current controlled, so applied voltage will vary rapidly. Volt meter measurements are not possible.. depends on power source and should be in the range of 0 VDC.. Logic Pwr depends on the power source and should be in the range of 0 VDC. Soap Offload Water Solenoid. High frequency / high voltage signal cannot be measu with volt meter. System Wiring Diagrams00SREA

Rover System Overview Electrical Volume Display PCBA 0000 Volume Display ler RF Module 0000 Distribution PCBA 00000 Wireless ler ler Docker Tank (Valve) ler Docker Main ler PCBA 00000 Docker Main ler EDMS Main Stamp Docker Coupler PCBA 0000 Data Transfer Rover Coupler PCBA 00000 Rover Main ler PCBA 000000 EDMS Ministamp Rover Main ler Level Sensor FPGA Docker Coupler ler Transfer Large ler Small ler IV Pole ler Reader ler System Overview00SREA