THE LEADER The Leader IN DRY BULK in LEVEL Dry MEASUREMENT

Similar documents
Level Devices. Rotary Level Indicators Roto-Bin-Dicator

Super-Safe-Plus Roto-Bin-Dicator

THE ORIGINAL DRY BULK LEVEL MEASUREMENT & CONTROL

ROTARY Point Level Measurement for Inventory Control

PROCAP Capacitance Level Sensors

VRF II Series SURPASSING SENSITIVITY FOR THE TOUGHEST APPLICATIONS FEATURES AND BENEFITS STANDARD VS. ADVANCED UNITS

PROCAP Capacitance Level Sensors

Bin-Dicator FEATURES AND BENEFITS

IOM. LP-100 & LP-200 Pulse Point TM Installation & Operation Manual

Rotary Paddle Bin Monitor MODEL KA & KAX

The Mobrey product range provides reliable point level detection in a variety of dry solid applications

Mobrey dry products level measurement and control

R F C a p a c i t a n c e TrueCap

Mini-Roto TM Paddle Wheel Installation & Operation Manual

STOCKTROL-H VIBRATING LEVEL SWITCH. Instruction Manual June 2002

TUNING FORK LEVEL WORKING PRINCIPLE APPLICATION. Solid Level Detection FEATURE. For Liquid: * Water & Solutions * General Purpose Solvent * Petroleum

Just Level. Table of Contents. Model CPH Capacitive Proximity Switch TECHNICAL INFORMATION. Principle of Operation 2. Applications 3.

Vibrating Level Switches for Liquids & Solids HYC-VLS02 Elect. Iss. 02 SIL 2 APPROVED VIBRATING LEVEL SWITCHES FOR LIQUIDS AND SOLIDS

process measurement solutions The dry products level control catalogue

DIAMOND POINT VIBRATING PROBES

AMI. American Magnetics, Inc. Excellence in Magnetics and Cryogenics

PRO REMOTE Series CAPACITANCE PROBE

Model 5000 Level Controller

Model 5000 Level Controller

Level Measurement Point level measurement - RF Capacitance switches

BinMaster Price Book

MAIN FUNCTION FEATURES. . D = v t /2

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

ROTARY PADDLE LEVEL SWITCHES

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

CVR-625. Compact Vibrating Rod Instruction Manual

ISO-9001:2000 certified Aplus Finetek Sensor, Inc.

Roto-Bin-Dicator PRO Installation & Operation Manual

PRO REMOTE 25 LV CAPACITANCE PROBE

Screw Lift Conveyor for Efficient Elevation When Your Handling Problem Calls for Elevating Bulk Materials

Model DFX Doppler ultrasonic flow meter

Soliphant T FTM260. Technical Information. Level limit switch Cost-effective vibration limit switch for fine-grained solids

Bin Level Control. Original Roto-Bin-Dicator. Original Roto-Bin-Dicator Specifications

MODEL CMS INSTALLATION INSTRUCTIONS A. INTRODUCTION 1. USAGE 2 2. HOW IT OPERATES 2 B. SPECIFICATIONS 1. ELECTRICAL 3 2.

Plastics & Packaging ONE STOP SHOPPING. Canada USA

Z4-Series DREXELBROOK DATA SHEET. Easy-Installation. Z-tron IV Point Level Switch, a reliable low-cost, on/off level switch.

Lower maintenance costs: with no moving parts, there is nothing on the DFX to wear down. Wide measuring range: 0.15 to 30 FPS (0.05 to 9 MPS).

Bulletin No Vibrating Conveyors. For Bulk Material Flow, Batch Loading and Unit Handling

NIVOCONT R VIBRATING ROD LEVEL SWITCHES

BD SERIES BLENDERS Batch Weigh Blenders

for free flowing solids NIVOROTA ROTARY PADDLE LEVEL SWITCHES LEVEL SWITCHES

LTX RF LEVEL SENSOR. Instruction Manual

Electro-Sensors, Inc. Machine Monitoring Sensors & Hazard Monitoring Systems

ISTEC MAGNETIC METERS

RS85 Vibrating fork level switch

Precision Control Devices

Geo. Robson & Co. (Conveyors) Ltd Coleford Road, Sheffield, S9 5PA Tel. +44 (0) Fax. +44 (0) Registered in England No.

MAIN FUNCTION FEATURES. . D = v t /2

Mobrey 003 Ultrasonic Liquid Level Switch

Mobrey Squitch 2 Ultrasonic Liquid Level Switch

Application. Tek-Air Systems, Inc. 41 Eagle Road Danbury, CT (203) FAX: (203) SALES FAX: (203)

Probes.STD: Standard Probe (1, 3, 4, 5, 6).HIT: High Temp Probe (1, 3).SED: Sediment Probe (1, 3).SAN: Sanitary Probe (2)

FICHA TÉCNICA DE PRODUTO

BAKER-BOHNERT 1311 Bernheim Lane P.O. Box Louisville, KY Phone (502) FAX (502)

Flow Measurement Technology Training

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

FVC2100/2200 TEK-AIR TECHNICAL PRODUCT DATA SHEET FUME HOOD FACE VELOCITY MONITOR AND CONTROLLER. Application. General Description

Level Limit Switch soliphant FTM 930/931/932/ Z

Sola/Hevi-Duty S3K Series Mini-Tower UPS

P U L S A R point 210

Syntron Pneumatic Vibrators

ANSI Z50.1. Safety Standards

Level Measurement Point level measurement - Rotation paddle switches

Soliswitch FTE20. Technical Information. Point level switch for granular solids

Model 550 Series Vibration Switches

Series BFM Bulk Flow Monitor 1A FUSE RED LED RELAY. Part Number BFM-1 BFM-2 BFM-3 BFS-1

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

CAPTROL MODEL 500 MANUAL # R.F. Capacitance Point Level Switch

Point level measurement Capacitance switches

Electromagnetic Flowmeters. Product Overview.

SP/SF Series Flow Switches

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

MEMFlo MFTV METAL BODIED FLOW METER WITH CLEAR TOP

NIVOSWITCH R-400/R-500

Automation Capabilities

CAPACITIVE LEVEL SWITCHES. Capacitive switch catalogue HYC-CSC01 Elect. Iss. 01

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

Shaft Speed Switches. SCP Series Speed Switch. M Series Speed Switch M100T/M5000T. Our Most Popular Speed Switch!

DUST COLLECTION APPLICATION

Level Sensors and Switches Guided Radar (TDR) Radar Wave Level Sensors Ultrasonic Level Sensors Rotating Paddle Level Switches Vibrating Fork Level

Level Measurement. Point level measurement Capacitance switches. Pointek CLS300 Standard. 5/42 Siemens FI Overview.

PIG PASSAGE INDICATORS


Valve Solutions for the Bulk Material Industry

Gladiator. Acoustic Switch & Auto Spray Cleaner. Data Sheet. A Higher Level of Performance. Non-contact Self Cleaning Blocked Chute Detection

Service Instructions. Models: SLC-B & SXLC-B Hopper Level Control

Mechanical Diaphragm Metering Pump

Linear Valve Electric Actuator

GET OFF THE DOWNTIME ROLLER COASTER.

Dry Chemical Feed Systems

DIAPHRAGM METERING PUMPS

2N1 TM PROXSENSOR ACCESSORIES VALVE STATUS MONITOR SERIES 52 2 INDUCTIVE PROXIMITY SENSORS AC, DC & INTRINSICALLY SAFE VERSIONS

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

VAREA-METER FLOW MEASUREMENT BY-PASS TYPES

Transcription:

THE LEADER The Leader IN DRY BULK in LEVEL Dry MEASUREMENT Bulk Level Measurement

ORIGINAL, GENUINE Established in 1934, Bindicator has built level switches to solve the toughest bulk material handling challenges. We have more history and experience with dry bulk level measurement than any other company. There are over 1,000,000 Bindicator point level instruments at work every day around the world. PRODUCTS THAT ARE BUILT TO LAST Bindicator has always emphasized heavy-duty construction. Our designs are rugged. Bindicator products are built to withstand rough treatment and extreme environmental conditions. Our products are built in an ISO-9001 factory and are endorsed by leading approval agencies including Underwriters Laboratories, CSA, CENELEC, ATEX, and many others. APPLICATION EXPERTISE YOU CAN RELY ON Bindicator has more experience with dry bulk applications than any company in the industry. We have more products and accessories designed for dry bulk level measurement. Bindicator can solve your problem. Our application engineers have probably already solved the same problem for someone else. DEDICATED TO YOUR SUCCESS Bindicator stands behind its products. We have been a leader in the industry for decades because we deliver value. 2

Bindicator has a product that best fits your application POINT LEVEL CONTINUOUS LEVEL RF-8000 RF-9100/9200, 9000 RF-17000/18000 (remote) RF-11000/12000 (remote), 10000 Pulse Point TM LP-100 Material Powder Granular Slurry Liquid Material Density Low High Material Moisture Low n/a n/a n/a High n/a n/a n/a Temperature High [over 200 O (93 O C)] Pressure Atmospheric Low Medium Vibration Low High Material Coating Minimal Heavy Build Up Corrosive Low High Installation Vert. (top mount) Horiz. (side mount) Non-Contact Atmosphere Dust n/a n/a n/a Steamy Non-Air Vapor Pulse Point TM LP-200 (remote) Roto-Bin-Dicator Bin-Dicator Diaphragm Liquid Level Phase TrackerTM Level Data * * * Yo-Yo (Mark III, Mark-4, GP, GP II, & GP-4) Mach OneTM * Cap-Level II/IIA * * Contact your Bindicator Representative for more information about these and other products not listed in this brochure. 3

Roto-Bin-Dicator The Roto-Bin-Dicator is the most universal of all level sensing technologies and is the most popular level switch used in dry bulk materials. The Roto-Bin-Dicator is a rotating paddle type, bulk material level sensor offered in a wide variety of paddle options for unequaled application versatility. It is easy to install and requires no special tools or calibration. No Calibration Required High or Low Level Alarm Switch Top, Bottom, or Side Mount 1 or 2 SPDT Switches Explosion Proof & Stainless Steel Enclosures Available Special Motor Design Allows power to be applied all the time, producing heat and eliminating condensation 4

How the Roto-Bin-Dicator Works 1The Roto-Bin-Dicator incorporates a low torque, slow speed synchronous motor A. The motor rotates a paddle B which is extended into the bin. 2 As the material builds up to the Roto- Bin-Dicator, the paddle is stopped, which in turn stalls the motor. As the motor stalls, it actuates switches C. A C 3 The torque of the motor, while stalled, serves to keep the switches actuated while the paddle rotation is stopped by the presence of bulk material. B 4 The switches in the Roto-Bin-Dicator serve to energize audible and visual signal systems and/or stop and start machinery such as conveyors, elevators, feeders, etc. Roto-Bin-Dicator level switches can be used to eliminate bin overflow, empty bins, clogged conveyors, or choked elevators. Roto-Bin- Dicators can be used on practically any bulk material such as: ore coal feed grain powders chemicals aggregates food products cement Typical Applications 5

Roto-Bin-Dicator Super-Safe-Plus Roto-Bin-Dicator Fail-Safe Operation Optical sensor monitors the movement of the shaft. If the shaft stops turning for any reason, the unit will alarm. Provides notification of failure due to power loss, open or shorted motor circuit, component failure, mechanical failure of the motor or clutch in either high or low level applications Lights on Enclosure Cover Green LED indicates power and operation status; red LED indicates alarm and failure status External Function Test Magnetic fob can be used to test the unit without removing the cover while it is installed and operating Original Roto-Bin-Dicator Few Parts Low Level Fail-Safe Protection If power is lost, the unit will indicate a low level condition Low Torque Motor Ensures reliable indication--even on light materials Mini Roto-Bin-Dicator Compact Size Fits into tight places Injection Molded Construction Adjustable Sensitivity External LED Red light indicates alarm condition up to 50 ft (15 m) away 6

Two sizes available Molded neoprene flexible shaft available For heavy, medium sized materials over 75 lbs/ft 3 Used where surge pressures are excessive and less paddle drag is necessary Four Vane Paddle Single Vane Paddle Insertable Paddle Insertable thru 1¼" mounting coupling Curved 10" diameter Especially suited for aggregates For heavy, large lump materials Neoprene or stainless steel construction Long multi-flex available for heavy and/or sticky materials Multi-flex Paddle Pipe Extensions Bindicator manufactures custom length pipe extensions so that paddles can be vertically extended into silos when side mounting is not an option. High Level Alarm Liquid/Solid Interface Detect solid level within a liquid-filled tank Available in Galvanized or Stainless Steel The UL and CSA list the Explosion Proof Roto-Bin-Dicator for use in hazardous atmospheres Class I, Groups C and D; and Class II, Groups E, F and G. Explosion Proof 7

RF Series RF Series The Bindicator RF (Radio Frequency) Series is a family of point level switches used to detect the presence or absence of material at a point inside a tank, bin or other vessel. The RF Series is used for high and low level detection in thousands of applications from bulk solids to slurries and liquids. Bindicator s unique calibration technology overcomes problems associated with other capacitance probes. EZ-CAL Calibration Calibrate to air without removing the cover Test-In-Place TM Test by pushing a button, turning a key, or using a magnetic fob without removing the cover Calibration and Alarm Lights Green LED indicates calibration status; red LED indicates alarm status Calibration Indication Output Relay Green LED blinks and special relay switches to notify operator that calibration is necessary Field Selectable Fail-Safe Operation Pro-Guard TM Patented probe design ignores material build-up on probe DPDT Output Relay 8

How the RF Series Works 1The RF Series works on the radio frequency/capacitance principle. The sensing electronics have been designed to detect the difference between the electrical characteristics of air (no material) and the material being detected. A 2The detection circuitry A compares this signal with a fixed reference RF signal. The phase difference between these two radio frequency signals causes the output relay to alarm. 3The electronics sense a change in the electrical characteristics when material covers the probe B. The radio frequency signal driving the active sensing section of the probe will change when material is present. B 4EZ-CAL calibration allows calibrating the unit to air, without removing the cover or moving the material in and out of the vessel. The RF Series is well suited for severe applications including high temperatures, high pressures, and corrosives. Specific applications include, but are not limited to: coal flour Typical Applications asphalt food products pharmaceuticals calcium carbonate 9

RF Series RF Series Bindicator s Premier RF Model Calibration and test accomplished with magnetic fob Test-In-Place TM and EZ-CAL calibration without removing the cover Standard function test electronics Calibration and Alarm LEDs on cover RF-9200 integral RF-12000 remote Remote version of RF-9200 For high temperature applications up to 1000º F For high vibration applications EZ-CAL calibration with magnetic fob Why Remote? All Bindicator integral RF units have remote versions. Remote models separate the electronics from the RF probe, where conditions could be harmful. Allows mounting of electronics at ground level for easy access Remote electronics protect circuitry from excessive vibration and excessive heat 10

Bindicator manufactures 14 models of RF sensors, each available with many options and accessories. When combined with our large selection of probes, we have an RF sensor for virtually every application. Please consult one of our representatives or call the factory for application assistance. Many Models Available Pro-Guard Pro-Guard is a patented probe and circuit design that cancels out the effects of material coating A on the probe, preventing false indications. Two Ryton, polysulfone, or ceramic insulators B keep the probe signal from shorting to ground through the coating. In addition, an electrically active metal band generates a field of electricity that keeps the probe signal from shorting to ground. The combined effects of the insulators and the active guard make the RF Series with Pro-Guard the most reliable sensor for almost any application. A B B 11

RF Series RF Series RF Probes Standard Solids, powders and liquids in tanks and bins Stub Small hoppers and vessels Flush/Dome Flush Plugged chute detection; where bridged material may shear or bend other probes when material shifts; coal applications or where slightly conductive coatings may occur Cable Designed for high, mid, or low level indication when top mounting is necessary Ceramic For extreme temperatures up to 1000º F (538º C). Provides protection because electronics are mounted remotely from probe. Stub Flush/Dome Flush Cable Ceramic 12

Other RF Probes Kynar Coated Standard Corrosive chemicals, powders, liquids or solids, petroleum and organic products Kynar Coated Heavy Duty Corrosive chemicals, powders, liquids or solids where supplementary tip extensions are required Food Grade Food and pharmaceutical ingredients in storage tanks, production machines and hoppers Armored Food Grade Where material flow is abrasive to insulated portion of probe Heavy Duty Where supplementary tip extensions are required Teflon Jacketed Corrosive/harsh chemicals and materials which would attack or adhere to the probe Jumbo Corn or grain and other like materials with mid to high moisture and material densities greater than 30 lbs/ft 3 Fly Ash Designed specifically for fly ash applications and other hard-tosense materials up to 450º F (232º C) Probe Options Pipe Extensions This type of probe mounting is used in deep tanks. It may also be used to project probe through thick tank walls or insulation. Lagged Remote electronic unit is combined with pipe extension (lagging) for use in double-wall hoppers and bins. Protects electronics from high-temperature environment. Lagging may be sized to fit wall thickness of hopper or bin. Rigid or Flexible Tip Extension The rigid extension is used where it is desirable to increase the probe s length. The flexible extensions are used in aggregate, coal or other lump materials that might damage a fixed tip. Modified Probes All probes can be bent or cut when used inside hoppers, tanks and vessels where space is limited. Other modified probes are welded tip extensions and Kynar coated, welded tip extensions to a maximum of 5 feet (1.5m). 13

Pulse PointTM Point TM The Pulse Point TM is an electronic vibratory level control especially effective in lightweight powders and granular solids. Because the Pulse Point TM senses material using a mechanical principle, the dielectric constant of the material is irrelevant. No Calibration Required 1 1 /4 or 1 1 /2 NPT Top or Side Mount Dual-Tine, Self-Cleaning Action Won t rat hole like single-tine vibratory units Field Selectable Fail-Safe Operation Adjustable Time Delay Ability to Sense Lightweight Materials Down to 2 lbs/ft 3 LP-100 External function test using fob External LED operation and alarm lights DPDT output relay Lexan Light Guide Does not crack, leak and is impervious to sunlight Captive Screws LP-30 Low cost vibratory switch Dual conduit housing SPDT output relay LP-200 Remote version of LP-100 High temperature applications up to 248 O F (120 O C) 14

How the Pulse Point TM Works 1The TM Pulse Point uses a vibrating tuning fork to sense the presence of material. 2Piezoelectric crystals A in the base of the fork create and sense movement of the tines B. The electronics C and transmit crystal drive the oscillation, and when in air the tines vibrate at about 100 Hz. C A 3When material contacts the fork tip, the oscillation diminishes because the fork is now dampened by material contact. 4The receive crystal senses this difference and changes the state of the output relay. B The Pulse Point products are designed for use in dry materials that are heavily aerated such as: plastics sawdust insulation reground plastic film carbon black light fibers tobacco paper shavings dry cereals cement Typical Applications 15

Yo-Yo The Bindicator Yo-Yo is a reliable continuous weight and cable level measurement system designed especially for dry bulk materials. GP-4 and Mark -4 Silos up to 100 ft (30.5 m) 1cm (0.39 ) Resolution Reversible 4-20mA Output with Adjustable Span RS-485 (MODBUS) Communication Optional Integral Modem for Remote Communication Remote Display Programmer with Keypad GP-4 NEMA 4 Enclosure is Minlon frame w/low density polyethethylene cover Surface mount components Mark-4 NEMA 4/7/9 Rugged cast aluminum housing Surface mount components Web-based i-level Inventory Management Software Available Multiple systems supported; can be connected to a server via direct serial connections and modem connections Multiple users can access a server simultaneously using standard browsers Remote Display 4-line x 20 character backlit LCD display Monitors and requests readings of up to 99 silos Enables/disables sensors Programs parameters Also Still Available: GP, GP II and Mark III 16

1The Bindicator Yo-Yo is an electromechanical device consisting of a sensor mounted on the top of a vessel. How the Yo-Yo Works 2The sensor contains a weight... A suspended by a cable... B with motion provided by a motor drive... C and associated electronics. C 3The measurement cycle is initiated either on demand or on a timed interval and causes the sensor to lower the weight to the material level. As the weight is being lowered, the length of cable dispensed is measured in 1cm (0.39 ) increments. B 4When the weight reaches the material level, the unit reverses and the weight is drawn into the stored position in the sensor. The distance measurement can then be transmitted via 4-20mA, voltage pulses, or RS-485 MODBUS. A Typical Applications vessels and silos at atmospheric pressure aggregates plastic resin powders granules pellets liquids and liquid/solid interfaces 17

Bin-Dicator The original electromechanical point level switch, Bin- Dicator diaphragm-type level controls were the first to enjoy general usage in the industry. Bin-Dicator controls eliminate bin overflow, empty bins, clogged conveyors, choked elevators and resultant damage and waste. How the Bin-Dicator Works The Bin-Dicator control is a pressure actuated switch for use with free flowing bulk materials at atmospheric pressures. Actuation of the switch is the result of pressure exerted by the bulk material against the diaphragm assembly. De-actuation or switch release is a result of the bulk material clearing away from the diaphragm. Model "A" Auto-Bin-Dicator Bantam 10 1 /4 Diameter Explosion Proof Model Available 7 Diaphragm Material Options 8 Diameter Cast Aluminum Housing Stainless Steel or Neoprene Diaphragm Material 5 3 /4 Diameter 2 Diaphragm Material Options 18

Bin-Flo The Bin-Flo aerator is a simple and efficient means of introducing low pressure air into any dry finely ground material. The air is equally distributed in controlled quantities to give the material an ability to flow by gravity from bin, hoppers or chutes. Bin-Flo aerators incorporate non-clogging diffusers, integral orifice and construction features which assure long, maintenance-free life. 2 Sizes Available 2 Diffuser Materials Stainless Steel Body and Mesh Zinc Plated Body with Galvanized Mesh Internal or External Mount Bindicator s Flo-Guard is a stable and reliable Broken Bag Detector and a Flow/No-Flow Switch for dry, powdered, and granular materials. The Flo-Guard uses a floating alarm point reference and a digital triboelectric microcontroller to eliminate instability common in other flow switches. Fob Function Test Tests operation without cover removal Fast, Easy Set-up No lengthy calibration procedure External Alarm and Power LEDs Verify operation quickly Field Selectable Fail-Safe Operation Alarms on presence or absence of material flow Remote Version Available For ground level access, high vibration areas, or high temperature applications Flo-Guard 19