Arc Fault Circuit Interrupter (AFCI) FACT SHEET

Similar documents
FACT SHEET Standard: Electrical Safety

GFCI-AFCI FAQ. Where are AFCIs and GFCIs required?

Electrical Equipment and Terminology

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

An average of one worker is electrocuted on the job every day There are four main types of electrical injuries:

Electrical Safety. Recognizing & Controlling Hazards

ELECTRICAL. 60 Minutes

Chapter 4 Utility Systems Electrical

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL

CHAPTER V RESIDENTIAL WIRING

New Products for Integrated Electrical Systems/Questions and Answers/Resources. necdigest. Bringing a new level of electrical protection into the home

The Evolution of Arc Fault Circuit Interruption

Electrical Safety. Electrical Safety Webinar. Electrical. Printing Industries Alliance Printing Industries Alliance 1

Overcurrent Protection (2014 NEC) (Homestudy)

Fee $20 Course: NEC Changes 1 This course is valid for these credentials: Credential Description Cred Code Credit Hours

WIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST

9/7/2010. Objectives. Article 90. Introduction NEC Significant Changes. Review significant revisions in the 2011 NEC

2016 Photovoltaic Solar System Plan Review List

Section 8 Stab-lok Circuit Breakers

Chapter 8 Interior Wiring and Lighting

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/14/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

ECET Distribution System Protection. Overcurrent Protection

Electrical Safety. Introduction

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE

90.2 Scope. The installation of electrical conductors, equipment and raceways for:

Photovoltaic Solar Plan Review

Spring Test 10 due 05/11/2013

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

ELECTRICAL GROUNDING SAFETY PROGRAM

Permit for Charging Equipment Installation Electric Vehicle Supply Equipment (EVSE)

A Look at the 2017 NEC Significant Changes

Learning Module 10: Loadcenters. 101 Basic Series

Ten Deadly Conditions to Check for in Your Boat's Electrical System - Part 2

Load Side PV Connections

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

Overcurrent Protection According to the 2011 NEC

Western Section 101 st Annual Meeting Hot Springs, Arkansas September 21, 2005 Charlie Trout Code Breakfast

CHAPTER 10 ELECTRICAL. Notes:

2011 NEC Changes Part 2 (Homestudy) (Homestudy)

Elegance Electrician s Installation Guide

ELECTRICAL SAFETY. Safety Training For The Non-Qualified

Chapter 2 Wiring and Protection Article 200 Use and Identification of Grounded Neutral Conductor Chapter 1 General...9

2014 NEC Changes (Homestudy)

6/4/2017. Advances in technology to address safety. Thomas A. Domitrovich, P.E., LEED AP VP, Technical Sales Eaton

SECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems

FILE HOW TO REPLACE A GFCI BREAKER ARCHIVE

Circuit Concepts (Residential)

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

SOLAR PV STANDARD PLAN - COMPREHENSIVE Central/String Inverter Systems for One and Two Family Dwellings

Electrical Tech Note 105 Agricultural Engineering Department Michigan State University

Electrical Safety Program

2014 NEC Analysis Part 2

PROTECTION OF THE BRANCH CIRCUIT

Knowledge Objectives (3 of 3) Electricity. Skills Objectives (2 of 2) 12/20/2013

SINGLE PHASE WIRING SPECIFICATIONS

Line Gard. Underwriters Laboratories (UL) Applicable Code Notation

THREE PHASE WIRING SPECIFICATIONS

CAL/OSHA ELECTRICAL LOW VOLTAGE

2011 NEC Code Updates Part 3

2011 NEC Significant Changes Part 1 The following course will summarize many of the important changes to the NEC code.

Electrical Safety and Overcurrent Protection

Design Standards NEMA

Electrical Hazards in Construction

Solar PV Standard Electrical Plan

ECET 211 Electric Machines & Controls Lecture 1-3 (Part 2) Electrical Safety in the Workplace Electrical Safety in the Workplace

INSTALL CIRCUIT PROTECTIVE DEVICES

Understanding National Electric Code (NEC) tap rules How do they apply to circuit breaker terminals?

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

Corrections most seen on plan review October 18, 2017 David Rankin Seattle Department of Construction and Inspections

NEC 2017 Code Changes in Equipment for General Use

NEC REQUIREMENTS FOR GENERATORS

Fee $100 Course: NEC Proposed Changes Part 1 This course is valid for these credentials: Credential Description Cred Code Credit Hours

PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST

Home Electrical Protection Beyond the Code: Arc-Fault Circuit Interrupters

4 Electric Circuits. TAKE A LOOK 2. Identify Below each switch, label the circuit as a closed circuit or an open circuit.

CHAPTER 10 ELECTRICAL

32 IAEI NEWS March. April

Supply-Side PV Connections

Electric Drive Vehicle Infrastructure Training. Instructor s Manual. National Alternative Fuels Training Consortium

Current Ratings. Standards & codes note 1. Introduction. interest. By Steve Hansen Sr. Field Engineer

Table of Contents. Review Answers...84 Final Exam...85 quickstep Online Courses...88

2000 Cooper Bussmann, Inc. Page 1 of 9 10/04/00

Western Section IAEI Code Panel Questions

"ELECTRICAL SAFETY IN THE LABORATORY"

SOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST

Service Entrance Methods

Section 7 Safety Model Stage 3 Controlling Hazards: Safe Work Environment

2014 NEC Changes Part 1 (Homestudy)

/ 120-VOLT ELECTRICAL SYSTEM

TRANSMISSION SYSTEMS

Can Electric Vehicle Supply Equipment (EVSE) Be Cord-and-Plug Connected? Contents FIGURE 1.

CONTINUING EDUCATION FOR OREGON ELECTRICIANS NEC Code Change Part 1 8 Hours

Electrical Tech Note 106

Spring Test 7 due 05/03/2013

AVOIDING ELECTROCUTION HAZARDS

Unrestricted. S.Mukhopadhyay

EV Charging Station Submittal Requirements

Significant Changes to the Philippine Electrical Code 2009 Edition

Electrical Tech Note 111 Biosystems & Agricultural Engineering Department Michigan State University

INSTALLATION GUIDE AND USER MANUAL

Transcription:

Arc Fault Circuit Interrupter (AFCI) FACT SHEET THE AFCI The AFCI is an arc fault circuit interrupter. AFCIs are newly-developed electrical devices designed to protect against fires caused by arcing faults in the home electrical wiring. THE FIRE PROBLEM Annually, over 40,000 fires are attributed to home electrical wiring. These fires result in over 350 deaths and over 1,400 injuries each year 1. Arcing faults are one of the major causes of these fires. When unwanted arcing occurs, it generates high temperatures that can ignite nearby combustibles such as wood, paper, and carpets. Arcing faults often occur in damaged or deteriorated wires and cords. Some causes of damaged and deteriorated wiring include puncturing of wire insulation from picture hanging or cable staples, poorly installed outlets or switches, cords caught in doors or under furniture, furniture pushed against plugs in an outlet, natural aging, and cord exposure to heat vents and sunlight. HOW THE AFCI WORKS Conventional circuit breakers only respond to overloads and short circuits; so they do not protect against arcing conditions that produce erratic current flow. An AFCI is selective so that normal arcs do not cause it to trip. The AFCI circuitry continuously monitors current flow through the AFCI. AFCIs use unique current sensing circuitry to discriminate between normal and unwanted arcing conditions. Once an unwanted arcing condition is detected, the control circuitry in the 1 Ault, Singh, and Smith, 1996 Residential Fire Loss Estimates, October 1998, U.S. Consumer Product Safety Commission, Directorate for Epidemiology and Health Sciences.

AFCI trips the internal contacts, thus de-energizing the circuit and reducing the potential for a fire to occur. An AFCI should not trip during normal arcing conditions, which can occur when a switch is opened or a plug is pulled from a receptacle. Presently, AFCIs are designed into conventional circuit breakers combining traditional overload and short-circuit protection with arc fault protection. AFCI circuit breakers (AFCIs) have a test button and look similar to ground fault circuit interrupter (GFCI) circuit breakers. Some designs combine GFCI and AFCI protection. Additional AFCI design configurations are anticipated in the near future. It is important to note that AFCIs are designed to mitigate the effects of arcing faults but cannot eliminate them completely. In some cases, the initial arc may cause ignition prior to detection and circuit interruption by the AFCI. The AFCI circuit breaker serves a dual purpose not only will it shut off electricity in the event of an arcing fault, but it will also trip when a short circuit or an overload occurs. The AFCI circuit breaker provides protection for the branch circuit wiring and limited protection for power cords and extension cords. Single-pole, 15- and 20- ampere AFCI circuit breakers are presently available. WHERE AFCIs SHOULD BE USED The 1999 edition of the National Electrical Code, the model code for electrical wiring adopted by many local jurisdictions, requires AFCIs for receptacle outlets in bedrooms, effective January 1, 2002. Although the requirement is limited to only certain circuits in new residential construction, AFCIs should be considered for added protection in other circuits and for existing homes as well. Older homes with aging and deteriorating wiring systems can especially benefit from the added protection of AFCIs. AFCIs should also be considered whenever adding or upgrading a panel box while using existing branch circuit conductors. INSTALLING AFCIs AFCI circuit breakers should be installed by a qualified electrician. The installer should follow the instructions accompanying the device and the panel box. In homes equipped with conventional circuit breakers rather than fuses, an AFCI circuit breaker may be installed in the panel box in place of the conventional circuit breaker to add arc protection to a branch circuit. Homes with fuses are limited to receptacle or portable-type AFCIs, which are expected to be available in the near future, or AFCI circuit breakers can be added in separate panel boxes next to the fuse panel box. TESTING AN AFCI AFCIs should be tested after installation to make sure they are working properly and protecting the circuit. Subsequently, AFCIs should be tested once a month to make sure they are working properly and providing protection from fires initiated by arcing faults.

A test button is located on the front of the device. The user should follow the instructions accompanying the device. If the device does not trip when tested, the AFCI is defective and should be replaced. AFCIs vs. GFCIs The AFCI should not be confused with the GFCI or ground fault circuit interrupter. The GFCI is designed to protect people from severe or fatal electric shocks while the AFCI protects against fires caused by arcing faults. The GFCI also can protect against some electrical fires by detecting arcing and other faults to ground but cannot detect hazardous across-the-line arcing faults that can cause fires. A ground fault is an unintentional electric path diverting current to ground. Ground faults occur when current leaks from a circuit. How the current leaks is very important. If a person s body provides a path to ground for this leakage, the person could be injured, burned, severely shocked, or electrocuted. The National Electrical Code requires GFCI protection for receptacles located outdoors; in bathrooms, garages, kitchens, crawl spaces and unfinished basements; and at certain locations such as near swimming pools. A combination AFCI and GFCI can be used to satisfy the NEC requirement for GFCI protection only if specifically marked as a combination device.

Arc-Fault Circuit Interrupters (AFCIs) - Type and Performance Considerations In February of 1999, UL published the First Edition of the Standard for Arc-Fault Circuit-Interrupters (AFCIs), UL1699. According to the National Electrical Code (NEC), an AFCI is defined as a device intended to provide protection from the effects of arc faults by recognizing characteristics unique to arcing and by functioning to de-energize the circuit when an arc fault is detected. The 2002 NEC will require all branch circuits that supply 125-volt, single-phase, 15- and 20-ampere outlets installed in dwelling unit bedrooms to be protected by an AFCI listed to provide protection to the entire branch circuit. Branch Circuits A branch circuit is defined in Article 100 of the NEC as the circuit conductors between the final overcurrent device protecting the circuit and the outlet(s). The length of a branch circuit can vary from several feet to several hundred feet, and include from one to several outlets. Figure 1 shows a pictorial representation of a typical branch circuit that could be associated with a dwelling unit bedroom. Figure 1 Pictorial Representation of a Typical Branch Circuit (Not to Scale)

The branch circuit overcurrent protection is provided by a fuse or circuit breaker usually located in a centralized panelboard that is served with power by the local utility. As the name implies, overcurrent protection protects the branch circuit against any currents that are in excess of the rated current or ampacity of the branch circuit conductors. Overcurrents can be the result of overloads, short circuits, or ground faults. Overcurrent protection is provided to open the circuit if the current reaches a value that will cause an excessive or dangerous temperature in the branch circuit conductors or conductor insulation. The branch circuit conductors are normally contained within a non-metallic cable (NM-B), armored cable (AC), or a metal or non-metallic raceway such as conduit or tubing. Non-metallic cables and raceway systems contain a separate conductor for equipment grounding purposes. Metal armor cables and raceways may contain an equipment grounding conductor, but in most cases the metal itself is permitted to serve as the equipment grounding path. The branch circuit conductors extend throughout the building to outlets, which may be a receptacle outlet for connecting to cord- and plug-connected appliances, or to fixed equipment, such as a lighting outlet for a wall or ceiling mounted lighting fixture (luminaire). Receptacle outlets in the branch circuit provide for the connection of cordconnected appliances, which in a bedroom may include appliances such as portable lamps, clock-radios, and portable air heaters. The cords attached to these appliances are generally referred to as power supply cords, as they supply the power from the branch circuit to the cord-connected appliance. In some cases, a power supply cord is not long enough to reach from the intended location of the appliance to the nearest receptacle outlet. In these situations, a cord set, often referred to as an extension cord, is used to extend the length of the appliance power supply cord to the electrical outlet. Cord sets and power supply cords are made from flexible cords that have designations such as SPT-2 which is often used on portable lamps and light duty extension cords. Although flexible cords are not a substitute for fixed branch circuit wiring, they are tested for mechanical impact and flexural strength properties that are suitable for their intended application. Flexible cords may or may not be provided with an equipment grounding conductor depending on the application or appliance involved. Cord sets and power supply cords are not part of the branch circuit wiring, but since they extend power beyond the branch circuit, they can be subjected to the same overloads, short circuits, and ground faults as would the branch circuit wiring. Branch Circuit Protection The branch circuit overcurrent protective device (OCPD), (i.e. a fuse or circuit breaker), is specifically designed to protect electrical circuits, including the

branch circuit conductors and flexible cords, against the unwanted effects of overcurrents. For example, when too many products are plugged into the same electrical outlet, and the total load current exceeds the rating of the branch circuit (i.e. 15 or 20 amps), the OCPD will open the circuit before damage to equipment or a fire occurs. However, an OCPD is not designed to protect the circuit against arcing faults. Because of the time-current characteristics of the OCPD necessary to provide effective protection against overcurrents, some arcing faults, including damaging arcing faults, may have time and/or current characteristics below the threshold levels necessary to open the OCPD. Arcing Faults Arcing is defined as a luminous discharge of electricity across an insulating medium. The electrical discharge of an arc can involve temperatures on the order of several thousand degrees Celsius. In general, arcing can be divided into two categories: (1) non-contact arcing and (2) contact arcing. Non-contact arcing is arcing that does not require direct physical contact between the conductors where the arcing is taking place. With arcing between conductors separated by insulation, the mechanism of initiating an arc between stationary conductors separated by insulation will depend on the type and geometry of the conductors and insulation between them. Contact arcing is arcing that involves direct or indirect physical contact between the conductors or "electrodes" where the arcing is taking place, such as arcing between closing or parting conductors making or breaking a circuit. Arcing faults can occur in one of two ways, series arcing faults or parallel arcing faults. A series arcing fault can occur when one of the current-carrying paths (e.g. a single wire) in series with the load is unintentionally broken. For example, extreme flexing in an appliance power supply cord can cause one of the conductors to open and arc when flexed. Series arcing faults are limited in current to the load current of the connected appliance or appliances in that circuit. Parallel arcing faults occur when there is an unintentional conducting path between two conductors of opposite polarity, such as between a black and white conductor, or between a line conductor and ground. Parallel arcing faults generally involve high currents, as they are limited only by the available fault current of the circuit. AFCI Types The UL1699 Standard addresses several types of AFCIs. Each type of AFCI is intended for different applications and/or protection of different aspects of the branch circuit and extension wiring. Three types of AFCIs for permanent connection to the branch circuit are identified in UL1699 as follows:

Branch/Feeder AFCI This device is installed at the origin of a branch circuit or feeder, such as at a panelboard, to provide protection of the branch circuit wiring, feeder wiring, or both, against unwanted effects of arcing. This device also provides limited protection to branch circuit extension wiring (e.g. cord sets and power supply cords). These may be a circuit-breaker type devices or a device in its own enclosure mounted at or near a panelboard. Outlet Circuit AFCI This device is installed at a branch circuit outlet, such as at an outlet box, to provide protection of cord sets and power-supply cords connected to it (when provided with receptacle outlets) against the unwanted effects of arcing. This device may provide feed-through protection of the cord sets and power-supply cords connected to downstream receptacles. Combination AFCI This is an AFCI which complies with the requirements for both branch/feeder and outlet circuit AFCIs. It is intended to protect downstream branch circuit wiring, cord sets and power-supply cords. The NEC and AFCIs During the revision process for the 2002 NEC there were several proposals to revise Sec. 210-12 to require both a branch/feeder and outlet circuit AFCIs in branch circuits required to be protected (bedrooms). This would provide protection to both the branch circuit wiring, as well as cord sets and power supply cords that extend beyond the branch circuit. The Code Panel did not accept these proposals. There was also a proposal for the 2002 NEC to permit either a branch/feeder AFCI located at the origin of the branch circuit, or a new type of AFCI designated an outlet branch circuit type located at the first outlet receptacle. A proposed revision to UL1699 would include this new type of AFCI defined as follows: Outlet Branch Circuit AFCI A device intended to be installed as the first outlet in a branch circuit. It is intended to provide protection to downstream branch circuit wiring, cord sets and power-supply cords against the unwanted effects of arcing. These devices also provide protection to upstream branch circuit wiring. The final language agreed upon by the Code Panel for the 2002 NEC for Sec. 210.12 will indicate the following: All branch circuits that supply 125-volt, singlephase, 15- and 20-ampere outlets installed in dwelling unit bedrooms shall be protected by an arc-fault circuit interrupter listed to provide protection to the entire branch circuit.

AFCI Tests As the UL1699 Standard continues to develop and address different product types and technology enhancements, it is important to understand how each type of AFCI is suitable for protecting various regions of the entire circuit against arc faults, and the extent and conditions under which this protection will be provided. Four different arc-fault tests are identified in UL1699 as shown in Figure 2. Tests Carbonized path arc ignition test <series> Branch/ feeder AFCI Combination AFCI Outlet branch circuit AFCI NM-B insulation cut X X X(+) <new> NM-B w/o gnd insulation cut X(+) Carbonized path arc interruption test <parallel> SPT-2 insulation cut X X X NM-B insulation cut X X X Carbonized path arc clearing time test <series> SPT-2 insulation cut X X <new> NM-B insulation cut X(+) Point contact arc test <parallel> SPT-2 insulation cut X X X NM-B insulation cut X X X (+) also includes an upstream insulation cut Figure 2 AFCI Arc-Fault Tests The Carbonized Path Arc Ignition Test is a non-contact arcing test conducted with NM-B cable with a series insulation cut. Tests are conducted with arcing currents of 5 A, 10 A, rated current, and 150% rated current. The Branch/Feeder, Combination, and Outlet Branch Circuit AFCIs are subjected to the Carbonized Path Arc Ignition Test. The Outlet Branch Circuit AFCI is subjected to the Carbonized Path Arc Ignition Test with the arcing occurring upstream, to represent series arcing in the branch circuit wiring between the origin of the branch circuit and the first outlet receptacle. The Outlet Branch Circuit AFCI is also subjected to the Carbonized Path Arc Ignition Test using NM- B cable without a grounding conductor, as may be found in some older homes built over 40 years ago. The Carbonized Path Arc Interruption Test is a non-contact arcing test conducted with NM-B cable and SPT-2 flexible cord with a parallel insulation cut. Tests are conducted with arcing currents of 75 A and 100 A. The Branch/Feeder, Combination, and Outlet Branch Circuit AFCIs are subjected to the Carbonized

Path Arc Interruption Test, however, the Outlet Branch Circuit AFCI is not tested with this parallel arcing occurring upstream from the device. The Carbonized Path Arc Clearing Time Test is a non-contact arcing test conducted with SPT-2 flexible cord with a series insulation cut. Tests are conducted with arcing currents of 5 A, 10 A, rated current, and 150% rated current. The Outlet Branch Circuit and Combination AFCIs are subjected to the Carbonized Path Arc Clearing Time Test. The Branch/Feeder AFCI is not subjected to this series arcing test with flexible cord as found in many cord sets and power supply cords. The Outlet Branch Circuit AFCI is subjected to the Carbonized Path Arc Clearing Time Test with NM-B cable and the arcing occurring upstream, to represent series arcing in the branch circuit wiring between the origin of the branch circuit and the first outlet receptacle. The Point Contact Arcing Test is a contact arcing test conducted with NM-B cable and SPT-2 flexible cord with a parallel insulation cut. Tests are conducted with arcing currents of 75 A through 500 A. The Branch/Feeder, Combination, and Outlet Branch Circuit AFCIs are subjected to the Point Contact Arcing Test, however, the Outlet Branch Circuit AFCI is not tested with this parallel arcing occurring upstream from the device. Further Information For more information on AFCIs, see the Regulators Page on the UL Web site at: http://www.ul.com/regulators/afci/index.html