OPTIMIZING COMMERCIAL SOLAR

Similar documents
Get More When Shopping for Solar

RE10 tenksolar System Overview

Residential microinverter system

Why array oversizing makes financial sense

MICROINVERTER ANALYSIS

SolarEdge. Distributed Solar Power Harvesting Systems. Company Presentation SolarEdge

* Protected from tools and particles greater than 2.5 millimeters * Protected form low pressure water jets from any direction

NC PV DG Program SEPA Presentation. December 15, 2011

Sunny Tripower CORE1.

Productive. Reliable. Smart. Safe. Brandon J. Pierquet. The Impact of Microinverters in Photovoltaic Systems Enphase Energy

SOLAREDGE S STOREDGE SOLUTION

Code Calculations. for an Off-Grid PV System

SolarEdge. Distributed Solar Power Harvesting Systems. Company Introduction SolarEdge

Components for your PV Solar Electric System

3 Phase Power Systems - Designed for Canada

Figure 1b: Daily Production Profile Non Power Limiting Day

SOLAR ELECTRIC INVESTMENT ANALYSIS

SolarEdge Solution - Making PV Panels Smarter GGS. Greener Gas Scotland Renewables & Heating

FRONIUS RAPID SHUTDOWN BOX MOUNTING OPTIONS For Rail and Rail-less systems on L-feet, stand-offs, and other attachment types

Commercial PV Projects with AEE Solar

ALBERTA SOLAR MARKET OUTLOOK. CanSIA Solar West 10 May 2017

672W Off Grid Residential Package

Solar Photovoltaic Power. Overarching Objectives. How many questions? 9/16/2012. From plan review to Final Inspection

Segen offer the SE2200, SE3000, SE3500, SE3680, SE4000, SE5000 and SE6000 single-phase inverters at great value prices.

Arial Regular 25pt. Learn Solar Installation From the Pros!

Residential Photovoltaic (PV) Packet

StorEdge Solar and Energy Storage System Review

Solar Technology & Applications Overview. Alexander Wolf Frankensolar Americas Mike Jeffrey Guillevin Greentech

SOLAR PV STANDARD PLAN - COMPREHENSIVE Central/String Inverter Systems for One and Two Family Dwellings

All of Texas Has Excellent Solar Resources. United States Solar Installed (as of mid 2013): 10 GW Germany Solar Installed (end of 2013): 35.

SOUTH HADLEY ELECTRIC LIGHT DEPARTMENT Net Metering Policy As Amended 03/23/16 By the South Hadley Municipal Light Board

Off Grid Residential Package 1.0KW

Residential Solar Electricity in Canada

2016 Photovoltaic Solar System Plan Review List

STREAMLINED SOLAR CHECKLIST Owner Name:

Micro3 Grid Tied Residential Package

Y9. GEH2.3: FREEDM Cost Benefit Analysis based on Detailed Utility Circuit Models

Solar Power. Demonstration Site. Annual Performance Report 2017

Requirement Definition/Terms of Reference Satellite Beach City Hall - Solar Array Installation

Copyright 2012 DelSolar Co. Ltd MQWRD installation manual-iec Ver. 1.4

24. SOLAR INCENTIVE PROGRAM II

Module-Integrated Power Electronics for Solar Photovoltaics. Robert Pilawa-Podgurski Power Affiliates Program 33rd Annual Review Friday, May 4th 2012

Off Grid Cabin Special Pkg 1-170W PV

PV Vault Yielding safety quickly

MONO-SILICON AC MODULE

Information Packet Kissimmee Utility Authority Customer-Owned Renewable Generation Interconnection And Net Metering Program

There s a new power in Solar 1500V ultra-high power string inverters for utility-scale PV applications

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

ALZ Electrical Solar Consumer Guide

SOLAR TRACKER SITE DESIGN: HOW TO MAXIMIZE ENERGY PRODUCTION WHILE MAINTAINING THE LOWEST COST OF OWNERSHIP

Residential Solar Electricity in Canada

OPTIMIZATION OF DC PLANT TOPOLOGY USING AE 1000NX INVERTERS

The microinverter The latest in solar technology

ABB solar inverters Product portfolio

Health & Safety Issues Associated with Solar Photovoltaic (PV)

Solar Photovoltaic (PV) Design Considerations & Issues. By Paul M. Williams, President & CEO

INSTALLATION MANUAL.

Your home and business energy independance. Energy Bundle CA5000TPV-3D

Solar Electric Modules

SOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST

Solar inverter From Wikipedia, the free encyclopedia

The potential for local energy storage in distribution network Summary Report

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

Solar Seminar. July 21st, Barry Cinnamon

Municipality Generator Interconnection Application Single Meter Application Part I

Calculating AC Line Voltage Drop for M215 Microinverters with Engage Cables

U.S. Photovoltaic Roadmap Perspective from a Manufacturing Industry. Subhendu Guha United Solar Ovonic

Green Building Technology

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings

Solar PV Standard Plan Simplified Microinverter and ACM Systems for One- and Two-Family Dwellings

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings

For the highest caliber solar system choose Rosendin Electric s exceptional collaborative team

Pika Energy Island Made in America

Project Title: Contract Number: Milestone Number: Report Date: Contract Contact: Phone: Congressional District: Executive Summary:

Airports Going SOLAR! Michael Shonka

Hikam America Inc. Professional PhotoVoltaic Cable Solutions. Company

Trinasmart SEUK Oct Daniel E. Mamat Product Management

Application Note Three Phase String Inverters NEC 2014 Compliance

SMART SOLAR SOLUTIONS FOR ROOFTOP ENERGY IN NORTH AMERICA

Update on State Solar Net Metering Activities Lori Bird, NREL RPS Collaborative Summit Washington, DC September 23, 2014

Gay E. Canough. OFF-GRID Design. Dr. Gay E. Canough, Master trainer. Living Off the Grid

Solar*Rewards Frequently asked questions system size and customer usage

City of Banning Electric Utility - Residential Self Generating Facility Program (Photovoltaic Systems <48kW)

Job Address: Permit #:

Commercial 1000VDC String Inverter XGI Installation and Operation Guide Models: XGI XGI

40kW (and under) Solar/Inverter Installations Generation Interconnection Application to Minnesota Power

RESIDENTIAL PHOTOVOLTAIC (PV) PACKET

A member-consumer with a QF facility shall not participate in the Cooperative s electric heat rate program.

Net Metering Service. Customer Information Package

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

Schneider Electric PV Skid. Optimized solar power conversion system tailored to enhance any North American PV power plant

Lassen MUD PV BUYDOWN PROGRAM Photovoltaic Systems Guidelines

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

Minnesota Dept. of Commerce, Division of Energy Resources. Distributed Generation Workshop Interconnection Standards

Questions from the AHJ To Fuse or Not to Fuse?

SMA COMMERCIAL PRODUCTS SUNNY TRIPOWER CORE1. Stands on its own. Up to 60 % faster installation for commercial PV systems

SANTA CLARA CITY RENEWABLE NET METERING & INTERCONNECTION AGREEMENT

SECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

LAYOUT REPORT OF ROOFTOP PROJECT. For 115 kwp. Order No. # Date 13 October, Name of Place California.

Transcription:

OPTIMIZING COMMERCIAL SOLAR SolarEdge s optimized inverter solution was able to reduce the DC side electrical BOS costs to less than 1 cent per watt for a total savings of almost 50 percent when compared to conventional central inverters. A study conducted by 3 rd party engineering firm Solvida compared three inverter solutions: 600V central inverters, 1000V string inverters and SolarEdge s 3-phase commercial inverters. SolarEdge demonstrated the greatest cost reduction in ebos costs, nearly eliminating the DC-side ebos entirely. Furthermore, SolarEdge s warranty gives it the edge in total lifetime cost making it the best overall solution for a lower cost of electricity.

Selection Drives Significant Cost Implications In 2013, for the second year in a row, U.S. commercial solar installations exceeded 1 GW. As interest continues to build for solar energy in private and public non-residential applications, SEIA/GTM estimate that annual commercial solar installations will exceed 3 GW by 2016. While previous cost reduction initiatives have been mainly driven by PV modules, future cost reduction is expected to come mainly from Balance of Systems (BoS) components. Areas like soft costs (permitting, site design, customer acquisition), electrical hardware and installation labor will require innovation to meet future costs goals. But cost reduction is not just about the raw cost of components. For example, inverter selection affects not only the price paid for the inverter, but also electronic Balance of System (ebos) and labor costs. While the inverter cost is only around 10 percent of the total system cost, the total impact of inverter selection can represent around 25-30 percent (Figure 1). U.S. Commercial Rooftop PV Breakdown, 2013 3% 9% 23% 10% 25-30% 9% 19% EBOS Labor Module Structure SBOS Soft Costs 27% Figure 1 Greentech Media To reduce ebos costs, many inverter manufacturers have started to supply UL certified 1000V inverters to the US market. These inverters increase the number of modules that can be installed on a string and thus reduce the homerun wiring and combiner box requirements. String length in traditional string inverters is a function of the module voltage at open circuit, temperature adjusted for a region s coldest weather. Since module voltage increases at open circuit (relative to maximum power point) and voltage increases with lower temperatures, this represents the highest likely voltage that a PV module will experience. However, the implication of a higher voltage is a shorter string length. For 600V systems, a string of 72-cell modules may only reach 12 modules. With a 1000V system, the total voltage increases by 67 percent, meaning that the module count will also increase by this same ratio to 19 modules. Module Level Power Electronics (MLPE), such as DC optimizers, work on another premise. Instead of increasing system voltage, they decrease module voltage. Some power optimizers help by clipping voltage at a level similar to the maximum power point voltage. This means that adjustments made for open circuit voltage and temperature can be negated. By clipping voltage, a power optimizer can increase string length by 30 percent.

However, SolarEdge power optimizers don t just clip voltage they control the voltage. SolarEdge inverters work in an advanced Fixed-Voltage mode. The power optimizers receive power from the PV modules and output a total voltage equal to the optimal conversion voltage for DC to AC conversion. The total voltage of all module power optimizers is a fixed value governed by the inverter s current draw. With full control over the power optimizers voltage output, SolarEdge is able to increase string length by over 100 percent. Three phase systems designed with SolarEdge can have strings of up to 12,750 watts. This means that each 20kWac SolarEdge inverter can be loaded with 25kWdc on only two strings drastically reducing system ebos requirements. Module Power (input): Voltage and current depend on module & environment Voltage* Current* Power 35V 7A 245W * at maximum power Optimized Power (output): Voltage lower by 50% Current higher by 200% Power is the same 17.5V 14A 245W Base System Requirements Figure 2 Solvida Energy Group, an independent third party engineering firm, conducted an analysis looking at ebos for a 500kW commercial rooftop array in Bakersfield, California utilizing common installation practices with 1,680 72cell 300W modules (Figure 3). The study compared a 600V central inverter, a 1000V string inverter and SolarEdge s SE20KUS inverter coupled with P700 power optimizers that enabled a 2:1 connection of 2 72-cell modules in series to a single power optimizer. PV Array Wire LV AC Interconnect Figure 3

Option 1: 600V Central Designed as a system that sits on a concrete slab on the ground level, the 600V central inverter must take the DC power from the roof top to the ground level and transfer AC power into a low voltage AC interconnect (Figure 4). Due to NEC requirements, the 600V central inverter can only support 12 modules per string resulting in 140 strings. A designer must include for each string: combiner boxes, fusing protection and an array Re-Combiner to combine the conductors from each combiner box before reaching the inverter. Each string of modules will also require cabling to reach from the combiner box to the start of the string and cabling from the end of the string back to the combiner. These cables are commonly know as homerun cables. However, since the inverter is located at ground level, it can be placed near the low voltage AC interconnection resulting in relatively low AC ebos costs. Solvida s analysis concluded that the ebos on the DC side was $0.13/watt and the ebos on the AC side was $0.05/watt, for a total of $0.18/watt (Table 1). Central PV Array Figure 4 Wire (DC) Central 600 V =/~ LV AC Interconnect ebos c/w dc DC Labor 6.9 DC Materials 6.1 AC Labor 1.2 AC Materials 3.4 TOTAL 17.6 Table 1

Option 2: 1000V String Compared to a central inverter, a 1000V string inverter has more advantegous mounting options such as on the side of the building or next to the racking. In the study, the inverter was placed adjacent to the racking to lower the DC side cost as much as possible and to comply with NEC 2014 rapid shutdown requirements (Figure 5). The study modeled a 27.6 kwac transformerless 1000V inverter. The inverter included an additional cost for an integrated combiner option. This combiner option satisfied the requirements to fuse and combine the multiple DC strings. It is treated as a cost in the ebos materials section for the assessment but requires no added labor to install. The 1000V string inverter enabled longer string lengths of up to 19 modules an increase of almost 60 percent. The total number of strings was reduced to 90 strings on a total of 15 inverters. The longer strings reduced costs in homerun cabling and in combiner boxes while the inverter placement reduced the need for long DC runs to ground level. However, increases in the AC ebos occurred to transfer power from the rooftop to the low voltage AC interconnection. With a 1000V string inverter, total ebos costs were reduced from $0.18/W to $0.14/W almost a 25 percent reduction. The DC costs reduced to less than $0.07/W while the AC costs increased to over $0.07/W (Table 2). String ebos c/w dc PV Array Figure 5 =/~ String 1000 V Wire (AC) LV AC Interconnect DC Labor 2.3 DC Materials 4.2 AC Labor 2.6 AC Materials 4.7 TOTAL 13.8 Table 2

1 Power Optimizer 2 3 2:1 configuration 9kW - 20kW Option 3: SolarEdge Figure 6 Monitoring Communication & Control Gateway Firefighter Gateway SolarEdge s module level power electronics solution consists of three parts: a power optimizer, an inverter and a monitoring portal (Figure 6). Power optimizers improve energy harvest by placing a Maximum Power Point Tracker at the module level with 15 milliseconds resolution. Power optimizers also condition the power from the modules eliminating losses due to current mismatch and they decrease voltage to increase string length. SolarEdge s power optimizers can improve string length up to 12,750 watts per string over 100 percent longer than traditional string inverters (Figure 7). Furthermore, the 2:1 power optimizer configuration helps bring cost down on the rooftop by reducing part count by 50 percent. SolarEdge offers 2:1 configuration for both 60 and 72-cell modules. 600V 1000V 12,750 Watts SolarEdge Figure 7 - for 250 watt modules

SolarEdge s inverters operate in an advanced Fixed-Voltage mode and have been designed to work exclusively with power optimizers. The SolarEdge three-phase inverters offer native support for 208Vac and 480Vac grids avoiding additional transformer costs and energy losses. The 20kWac inverter from SolarEdge can be loaded with a 1.25 DC:AC ratio, meaning a 25kWdc rating at full load. By maxing out the dc power on each sting, an installer can fully load the 20kWac inverter with only two strings; there is no need to combine or fuse the DC side of a SolarEdge system. The 20K inverter s weight of less than 80 lbs. enables a wider range of mounting options. Weighing a little more than a 72-cell module, the inverter can be easily installed next to the PV module racks. Similar to the 1000V string inverter design (Option 2), this configuration avoids added costs in regions adopting NEC 2014. In the analysis, the SolarEdge system design included the maximum number of modules per string. Each module represented 300W at standard test conditions (STC). For the maximum power rating of 12,600 watts, the design utilized 42 modules per string (Figure 8). By running the string 21 modules down and 21 modules back, the 42 module string could reach 140ft on the rooftop (without obstructions). This configuration was used as it fits well within the IFC 2012 regulatory limit of 150 feet. For this design, homerun cables were eliminated as well, leaving only small jumper cables to reach from the PV modules at the row end to the inverter. The design eliminated combiner boxes and fuses using the SE20kW inverters two native inputs to make all connections. ~4ft 21 20 19 2 1 ~4ft 22 23 24 41 42 ~4ft ~4ft Figure 8

As a result of the elimination of the components, the DC side material and labor nearly reached zero cents per watt. Some minimal labor and components remain for the SolarEdge system. The DC side analysis includes the labor to install all of the optimizers, the labor and materials for jumpers to connect from the optimizers to the inverters and the labor to mount the inverters. On the AC side, costs did increase slightly due to the smaller inverter sizing. The SolarEdge inverter was a 20kWac inverter while the 1000V string inverter was 27.6kWac. The smaller inverter led to more AC connections and a higher overall AC cost of 8c/W. However, the dc side costs were less than 1c/W meaning that in total, the SolarEdge system was less than 9c/W (Table 3). ebos c/w dc DC Labor 0.3 DC Materials 0.3 AC Labor 3.4 AC Materials 4.9 TOTAL 8.9 Table 3 In addition to lower ebos costs, SolarEdge systems have no requirement to match string module counts. This is a typical limitation of traditional string inverters to keep voltages matched when making parallel connections. SolarEdge power optimizers condition the power and allow different string lengths to be used in parallel. This means, for roofs with obstructions, onsite rework is possible without creating string voltage imbalances. For example, if a vent pipe is missed in the design, an installer can simply remove the single module without any electrical impact to other modules in the array. Summary of Results Comparing all three systems side by side, the Solvida study concluded that the SolarEdge system had the lowest ebos costs (Table 4). The 600V central inverter costs were the highest mainly due to the limitations on string length and the resulting extra expenses for homerun cables, combiner boxes, fuses and recombiner boxes (Figure 9). The 1000V string inverter and SolarEdge system achieved significant cost savings when compared to the 600V central inverter due to longer string lengths. However, the SolarEdge System was the only system to fully load the inverter on two strings and therefore gained most of the cost advantages through elimination of DC components like combiner boxes and fusing. Sensitivity analysis also showed that in areas with higher labor rates, the SolarEdge cost savings would be higher. Central 600 String 1000 SolarEdge c/w c/w c/w DC Labor 6.9 2.3 0.3 DC Materials 6.1 4.2 0.3 AC Labor 1.2 2.6 3.4 AC Materials 3.4 4.7 4.9 Total 17.6 13.8 8.9 Table 4 3.4 1.2 6.1 6.9 4.7 2.6 4.2 2.3 AC Materials AC Labor DC Materials DC Labor 4.9 3.4 Central 600 String 1000 SolarEdge Figure 9 0.3 0.3

Conclusion: Assessing Total Lifetime Costs The challenge for the US solar industry is in reducing all costs of a PV installation and not just the ebos. When comparing the total cost, project developers need to evaluate the ebos materials and labor, inverter costs and lifetime costs for the inverter. Most inverters today come with a standard 10 year warranty. Thus, to avoid any hidden charges, owners of PV installations should include the cost of a replacement during the 20 year lifetime to accurately forecast the cost of electricity. For the central and string inverters that cost can be modeled in a few different ways: warranty extensions to 25 years, net present value of replacement inverters or service contracts. For this study, we will use the warranty extension price for 25 years as it is the most verifiable number of the three choices. The SolarEdge system offers the lowest lifetime costs (Figure 10). The SolarEdge inverter includes a standard 12 year warranty while the power optimizer s warranty guarantees 25 years. Thus, the warranty extension is only required for the inverter portion of the SolarEdge installation. As a result, the warranty extension total cost is about one-third the cost of competing warranty extensions. Lifetime Costs Commercial System SolarEdge ebos (M+L) Power Optimizer Replacement 1000V String 600V Central Figure 10 In comparing the material costs, ebos and life time costs of a central inverter, 1000V string inverter and SolarEdge system the Solvida study demonstrates that the SolarEdge system offers the lowest total cost of electricity. The SolarEdge system is able to achieve the lowest cost through the elimination of ebos components and the efficient deployment of fixed-voltage inverters and power optimizers. The SolarEdge system demonstrated a lower total cost of ebos by more than 50 percent compared to 600V central inverters and 35 percent to 1000V string inverters. To learn more about SolarEdge s solutions for commercial solar, contact sales@solaredge.com.