Similar documents
ABB MNS 5 essentials of low voltage switchgear solutions

Exceeding the standards with MNS

Product Specification

ABB Low voltage systems MNS Platform

M2004. Document ID: 3HAC Revision: - Copyright 2010 ABB. All rights reserved.

Brochure. Modular Systems wind portfolio Power Collection and Grid Connection products

Low Voltage Systems MNS platform

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

Transforming Transforming Advanced transformer control and monitoring with TEC

Operators and Maintenance Manual. Display EEM MOT 01 FE02.02

Relay Retrofit Program for REX 521 Cutting Tool Safety Guide

Product Specification

ABB life cycle services Uninterruptible power supplies

Relay Retrofit Program Cutting Tool Safety Guide

ABB Robotics. Product manual, spare parts Motor Units and Gear Units

EVlink Parking charging stations. Simpler for drivers. Smarter for your city.

Aura Interior Wiring Manual (5-Wire and BACnet)

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

Modular Standardized Electrical and Control Solutions for Fast Track Projects

Brochure. Synchronous generators for steam and gas turbines Proven generators reliable power

Lighting Control Unit Installation Instructions

Life cycle services for protection and control relays Full support from start to finish

High-speed permanent magnet motor solutions from SKF Optimizing energy efficiency and reliability at wastewater plants

Protection & Control / Commissioning Engineer

ABB s Global Pulp & Paper Service Center of Excellence Raises the Bar. By Paul Miller and Larry O Brien

80V 300Ah Lithium-ion Battery Pack Data Sheet

EU RO Mutual Recognition Technical Requirements

Low voltage AC drives. ABB component drives ACS to 2.2 kw / 0.25 to 3 hp Catalog

PRODUCT PORTFOLIO. Electric Vehicle Infrastructure ABB Ability Connected Services

CATALOG. ABB micro drives ACS55, 0.18 to 2.2 kw

Monicon Instruments Co., Ltd. CHR-1285/2485 CHR-1285/2485 BATTERY CHARGER

CHAPTER 25. SUBSTANTIVE RULES APPLICABLE TO ELECTRIC SERVICE PROVIDERS.

e 2 ALPHA Medium Voltage Switchgear K Catalogue EN

SYSTEM INTEGRATION. Railway and urban transport electrification Energy-efficient and reliable solutions

Features and Benefits

SecoVac * Ground & Test Device

GUIDE FOR MICROGENERATION INTERCONNECTION TO CITY OF MEDICINE HAT ELECTRIC DISTRIBUTION SYSTEM

PPMV, South Africa, Manie Jooste, 22 May ABB Modular Systems

Arc-Flash Mitigation Technologies. Dennis Balickie

12 Volt Utility Controller for 4, 6 or 8 Brakes No P

Brochure. Arc Guard System TVOC-2 A protection device for reliable safety

Reference Number PDS 18 - (RIC Standard: EP SP)

Remote Vehicle Control System. Keyless Entry & Remote Start System

DC Tarction Power Supply Global product offering for DC traction power supply applications

BU EPDS, GPG SERVİCE 3442, MARCH 2018 MNS Motor Management INSUM 2. 1TGA rev.06 - Life Cycle Policy

Remote Vehicle Control System. Keyless Entry and Convenience System

Safety Sentry Electronic Breakaway Switch

High Voltage Products. COMPASS Compact Prefabricated Air Insulated Substation

Welcome to ABB machinery drives training. This training module will introduce you to the ACS850-04, the ABB machinery drive module.

National Grid UK Electricity Transmission plc. NATIONAL SAFETY INSTRUCTION and Guidance

CONTENT 1 PICTURE GENERAL... 3

OPERATIONAL MANUAL EMBC-8025 INTELLIGENT BATTERY CHARGER. Version 1.5

SENTRY ISOBUS Tip Flow Monitor. Software Version 1.00

FUSERBLOC CD. The universal Fuse Combination Switch FROM 20 TO 1250 A. Industrial Switching & Protection Systems

Power/Vac Vacuum Replacement Breakers for GE Magne-Blast Type AM & AMH Breakers

BMW i. Freude am Fahren. Wallbox PURE. Installation instruction

PQstorI One stop solution for energy storage and power quality

INTERCONNECTION STANDARDS FOR PARALLEL OPERATION OF SMALL-SIZE GENERATING FACILITIES KILOWATTS IN THE STATE OF NEW JERSEY

ABB Robotics. Product manual, spare parts IRB 6640

Microgrid solutions Delivering resilient power anywhere at any time

SKF Grease injection system

Low and medium voltage service. Power Care Customer Support Agreements

Battery Life in Water Communication Modules

Measurement Products. WaterMaster electromagnetic flowmeter The perfect fit for all water industry applications

Nota Conductor s Chair

Dynamic DC Emulator Efficient testing of charging technology and power electronics

DER Commissioning Guidelines Community Scale PV Generation Interconnected Using Xcel Energy s Minnesota Section 10 Tariff Version 1.

MNS PDUpro Intelligent power distribution unit

A comparison of metal-enclosed load interrupter (ME) switchgear and metal-clad (MC) switchgear

Draglines. Product Line

Energy efficiency solutions Simple steps to reduce fuel consumption and your environmental footprint

Allen-Bradley Parts. CENTERLINE 2500 Motor Control Centers Installing, Joining and Splicing Columns. Installation Instructions. Catalog Number 2500

Optimizing Emergency Power Systems for Health Care Applications

Power Systems PU. HYOSUNG MV Gas Insulated Switchgear. ProGIS[MV GIS]

Unified requirements for systems with voltages above 1 kv up to 15 kv

LEDEEN SEF. Smart electric fail-safe actuator and control systems

High voltage products PASS M0S 252 kv Innovative solution for transmission substation up to 252 kv

B kv Gas-insulated Substations

Powering the most advanced energy storage systems

Centurion Shovel Control System Product Overview

Columbia Water & Light Interconnection & Net Metering Agreement Electrical Facility

Advanced Protective Relay Training

Design Considerations to Enhance Safety and Reliability for Service Entrance Switchboards

Senior Substation Project Lead Engineer

INTERCONNECTION STANDARDS FOR CUSTOMER-OWNED GENERATING FACILITIES 25 kw OR LESS PUBLIC UTILITY DISTRICT NO. 1 OF CHELAN COUNTY

Utility Controller Hand Air Operated

ValveLink SNAP-ON Application

XPC-EBP64 External Battery Pack User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

AMS ValveLink SNAP-ON Applications

FUNCTIONAL SAFETY SOLUTIONS in Solenoid Valves

Volume CHARGESTORM AB. User Guide CSR100

Switchgear and Distribution Systems for Engineers and Technicians

MEDIUM VOLTAGE PRODUCT. KECA 250 B1 Current Sensor Instructions for installation, use and maintenance

Principle Decision by the Central Experience Exchange Circle of the Notified Bodies and the GS Bodies according to the Product Safety Act ZEK

FIXED VCB AIR INSULATED SWITCHGEAR

Cooling Box XR CB-01. Operating Manual. Doc. no ; ver. 02

CHEMICALS AND REFINING. ABB in chemicals and refining A proven approach for transforming your challenges into opportunities

Product brochure. Medium voltage AC drive ACS 2000, kva, kv

ENVILINETM Reliable and efficient solutions for DC rail transportation

Operator s Manual. Fairbanks FH Series by Fairbanks Scales, Inc. All rights reserved. . Revision 1 06/2017

Transcription:

Low Voltage Switchgear MNS with Integrated VSD

Even better Introduction Variable Speed Drive (VSD) is the established technology for efficient operation and control of electric motors. It provides a system by which the voltage and frequency of the power supplied to the motor can be varied and controlled. This helps customers to operate a motor precisely at the process need and to use energy more efficiently and thus lower the environmental impact. In most practices, VSDs are powered from power feeders of switchgears or motor control centers and feeds the electric motors downstream. The VSDs are commonly installed freely on the wall or in separate enclosures. Much effort is consumed for engineering, procurement, project management, commissioning and maintenance throughout the life cycle of switchgears and VSDs, particularly when the equipments are sourced from different vendors. Single point purchase of MCC & VSDs Zero engineering and project management for customers Ease of dealing and cost saving Solution for speed and simplicity Eco-friendly The Innovation ABB breaks the barrier by integrating the two leading technologies: MNS low voltage switchgear and ACS850 industrial drive. MNS with its distinctive safety characteristics and reliable performance track record is the preferred choice of the most demanding industries, while ACS industrial drive wins its rapport with robust design and energy conservation features. The integrated system combines the best of the both and enhances plant safety, process efficiency and energy saving. The ABB MNS integrated VSD system is precisely engineered in withdrawable and fixed techniques. The withdrawable technique is available up to and includes 45kW for 400V, and 55kW for 500V motors. It inherits the flexibility and features that are present in the MNS withdrawable motorstarter design. The fixed technique is designed for motors up to 160kW for 400V, and 200kW for 500V systems. The integrated VSD system offers customers a new horizon on managing the low voltage switchgear and VSDs. 2 ABB MNS with Integrated VSD

Safe and save VSDs in withdrawable technique Practical and safe Tested and verified Inherent safety of MNS technology Complete solution package with ABB expertise 61439 series Low-voltage switchgear and controlgear assemblies Higher Safety Occupational health and safety performance (OHS) is the top priority and key performance measurement for every organization. The integrated VSD system deploys the best of ABB expertise and devices in supporting customers enhance the OHS performance. In ensuring maximum human safety, the integrated VSD system is tested and verified according to IEC 61641 for Internal Arc Safety. This certifies the equipment s robustness to restrict the damage within the compartment where the arc flash accident happened. The assurance is further extended with the system rigorously type tested by third party test laboratories according to IEC 60439-1 and IEC 61439-2, and also fully verified according to IEC 61000 for Electromagnetic Compatibility (EMC). The MNS integrated VSD system is engineered and designed according to IEC 60947-4-1 which ensures short circuit device coordination. It is using ABB produced components only and thus guarantees customers the most optimized performance and highest quality. The integrated VSD system enables the new approach in operating and maintaining the VSDs. The functional unit at a single location alleviates the needs of operating and coordinating the physically separated power feeder at switchgear and VSD at a different location. Maintenance is made easier and safer with the power isolation clearly visible and secured at functional unit. The withdrawable technique ensures the maximum maintenance safety with the module being withdrawn and maintained away from the live bus. ABB advocates correct starting methods for different types of industrial objects (pumps, fans) based on industry application and usage. This is a realizable way for energy saving in site electrical installations. Energy Saving The correct starting and operating methods for different types of industrial objects (pumps, fans) based on industry application and usage are the keys for energy saving. Pump and fan applications are identified with biggest potential of energy saving. A pump or fan running at half speed consumes only one quarter as much energy as a unit running at full speed. The integrated VSD system adjusts the speed of the equipment driven by the motor by altering the voltage and speed. The adjustment refers to the external production parameters, for example flow rate or temperature of the driven equipment. The energy saving is therefore realized by having the motor running at various speed following the production system requirements. The ABB software tools PumpSave and FanSave are available to assist customers in estimating the potential energy savings in the specific customer applications. The tools are available for download at www.abb.com/drives, link Drive PC Tools. ABB MNS with Integrated VSD 3

More savings, better efficiency Optimizing engineering, procurement, project management, operation and maintenance. Lower Life Cycle Costs Conventionally customers spend much time and effort in specifying, preparing and evaluating tenders, project managing, commissioning, operating and maintaining the switchgear and VSD, with the goal of costs optimization. Such dedications however do not guarantee the expected results particularly when there are different vendors at different locations with difference competencies involved. 61439-1 The integrated VSD system offers the opportunity to work differently while delivering savings at every stage throughout the life cycle of the system. ABB renders professional project management on commercial and technical aspects reduces the risks and hours during engineering, procurement and project management. The design is highly standardized and customers can expect short delivery lead time. Only approved factories perform the assembly and every assembled unit is factory tested under the stringent quality control process of our world-wide valid quality control system. The quality is safeguarded and therefore the installation and commissioning hours at site can be significantly reduced. The highly standardized system also streamlines the spare part inventory. New way of operating and maintaining VSDs. Withdrawable units with VSD give high flexibility during operation 61439-0 User Friendly Operation and Control The withdrawable technique of integrated VSD system offers high flexibility during operation. Faulty units can be withdrawn and replaced with lowest mean time to repair (MTTR) to maintain high process availability. The communication fieldbus is streamlined with the ABB intelligent motor protection relays including UMC100, M10x and INSUM. Instead of separate fieldbus connection to the process controller, the integrated VSD system seamlessly integrates with the intelligent portfolio fieldbus as a single connection to process controller. In addition to the local operation panel, software tool DriveStudio supports the remote monitoring and management at a convenient location in the control room. Apart from the above, interconnecting cables between the switchgear and VSD are eliminated along with the cabling support and accessories. The VSD is no longer installed on the wall or in standalone enclosure allowing better flexibility and optimization in substation layout. Typically, the space saving aspect with integrated VSD s is high compared to separate enclosures or wall-mounted VSD s. 4 ABB MNS with Integrated VSD

Quick start up, guided maintenance Ready to use standardized modules No extra Power Feeder or intelligent module required Faster delivery lead time Space saving Project supervision and local site support. Swift Commissioning No doubt, MNS integrated VSD system allows swift project commissioning. With ABB taking on the responsibility of the switchgear and VSD, the current practice of commissioning personnel coordinate among different vendors for troubleshooting is a thing of past. The ABB supplied VSD integrated system eases and shortens the project commissioning phase. The integrated VSD system is tested and approved during the factory acceptance test ensuring proper operation, function and quality. The convenience of commissioning the functional unit at one location and software tools are the additional enhancements on commissioning experience. The reduction of commissioning and troubleshooting hours is easily recognized. VSDs in withdrawable technique Practical and safe Tested and verified Inherent safety of MNS technology Complete solution package with ABB expertise. Easy Maintenance ABB integrated VSD system is equipped with various diagnostics tools for supporting condition based maintenance. Alarms are triggered when major components require inspection and maintenance. The single functional unit of the integrated VSD system proves to be invaluable for maintenance. Isolation is conveniently visible and there are less components for maintenance with the absence of the switchgear-vsd interconnecting cable and the accessories. The integrated VSD system in withdrawable technique enables lowest mean time to repair (MTTR). The unit under maintenance can be withdrawn from the switchgear, and replaced by a spare unit of same rating. The motor can resume and maintain high process availability. ABB MNS with Integrated VSD 5

Contact us ABB Low Voltage Systems Local contacts on www.abb.com/mns Publication Editor: ABB Malaysia Sdn Bhd (210262-T) Lot 608, Jalan SS13/1K 47500 Subang Jaya Selangor Darul Ehsan, Malaysia Tel : +603 5628 4888 Fax : +603 5635 8200 Publication No. 1TPMC00401 Copyright 2011 ABB All rights reserved. ABB assumes no responsibility for any errors that may appear in this document. In no event shall ABB be liable for direct, indirect, special, incidental, or consequential damages of any nature or kind arising from the use of this document, nor shall ABB be liable for incidental or consequential damages arising from use of any software or hardware described in this document. This document and parts there of must not be reproduced or copied without ABB s written permission, and the contents thereof must not be imparted to a third party nor be used for any unauthorized purpose. The software described in this document is furnished under a license and may be used, copied, or disclosed only in accordance with the terms of such license.