Instruction Manual HMP TURBINE FLOWMETER. Anderson Instrument Co. Inc. 156 Auriesville Road Fultonville, NY Fax

Similar documents
Instruction Manual RZ POSITIVE DISPLACEMENT FLOWMETERS 2AU

Instruction Manual. RZ Positive Displacement Flowmeters 2AU

Instruction Manual. Model HC1 Series Electrodless Conductivity Sensors

DIGITAL REFERENCE THERMOMETER (DART)

MODEL 1100 TURBINE FLOW METER

Model 1100 Turbine Flow Meter

Liquid Turbine Flowmeter

MODEL 900 IMPELLER-TYPE FLOW METER

MODEL 200 MULTI-JET FLOW METER

MODEL 200 MULTI-JET FLOW METER

DIGITAL REFERENCE THERMOMETER (DART)

EZ-IN Series Turbine Flowmeter

Sanitary RTDs and Temperature Transmitters

FIXED DEPTH INSERTION METER INSTRUCTIONS

Turbine flowmeter HM-E / HMP-E

Model 1100 Turbine Flow Meter

Instruction Manual. Anderson Instrument Co. Inc. 156 Auriesville Road Fultonville, NY Fax

Watts Series CSM-61. Flow Measurement/Balancing Valves Sizes: 1 1 4", 1 1 2", 2", 2 1 2", and 3" (32, 40, 50, 65 and 80mm) Installation Instructions

INSTALLATION & OPERATION MANUAL

FR1118- P10. User s Manual

OVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ )

Tracer VM with User Interface

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Sanitary Turbine Flow Meter - TA3 Installation, Operating & Maintenance Manual

OPERATION MANUAL Variable Speed Pump Controller Dated: 06/04/2013 Pump Down Application. Document No.: LMSII_V100_OM Page 1 of 8 Model-V100 LMS II

TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual

Electronic Pulse Meters

Positive Displacement Flowmeters GM007 series instruction manual

A Member of the. Integrated Metering Technologies

A Member of the. Integrated Metering Technologies

INTRODUCTION INSTALLATION

HM860 FLOWMETER OPERATOR S MANUAL DO NOT USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND THOROUGHLY UNDERSTOOD

Mechanical Pulse Meter

Model 1100 Turbine Flow Meter Repair Kits

Tracer VMA with AutoReg

ENC 150 REFERENCE MANUAL ACU-RITE

TOUGH GARD Anti-Spatter Multi-Feed System

Nor East. Instructions Safety Messages. Inspection. Parts. DeZURIK Service. Type 05 Pneumatic Actuator Used With Globe Valves

RETROFIT SYSTEMS INSTALLATION AND SERVICE MANUAL. Engineered for quick and easy replacement of existing progressive cavity grinder systems.

Watts Series CSM-91. Grooved/Flanged Flow Measurement/Balancing Valves. Installation and Operating Instructions. Table of Contents. 1.

Positive Displacement Flowmeters GM020 series instruction manual

Analog Hydraulic Testers

MULTIPOSITION AIR CYLINDER

LEVEL AND FLOW MEASUREMENT WS131 FLOW METER USER MANUAL.

1 2-Inch Station Outlet Valves

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

Model BP6150. Triplex Ceramic Plunger Pump Operating Instructions/ Manual

AEROMOTIVE Part # Street Rod Fuel Pump System INSTALLATION INSTRUCTIONS

Old Proportioning Pumps

G8 Portable Fuel Transfer Pump Owner s Manual

Benchmark HD Series Heavy Duty Bench Scale. Installation Manual

POSITIVE DISPLACEMENT FLOWMETERS

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

Pump/Manifold Kits. Instructions F ENG. To convert E-Flo 4-Ball Piston Pumps to a different size lower. For professional use only.

ASM Maxi Poles. Instruction-Parts B Series. For the application of architectural paints and coatings.

BI-DIRECTIONAL INSERTION FLOW TRANSDUCER

BMK-30. Heavy-Duty By-Pass Filtration System Installation and Servicing Instructions

Active Controlled Cooling System

ZDM Positive Displacement Flow Meter User Instructions

SUNC3000 / Item #40885

TL-105-D COLUMN HEATER

Product Owner s Manual. 8 GPM / 30 LPM, 12-volt Fuel Transfer Pump. Model G8P

TS Series. MultiStage Centrifugal Pump Instruction Manual. Walrus America Inc. ISO 9001 Certified

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

Installation and Operating Manual

Model CP420/CP425. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual

GRINNELL Model B302 and Model BN302 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description

CRD610 Automatic Fitting Inserter

TOTALIZER-TRANSMITTER

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

P SERIES PUMPS. 18mm Versions Nickle-Aluminum Bronze Models: P , P , P , P , P , P , P

Turbine flowmeter HM-E / HMP-E

INSTRUCTION MANUAL. Rotary Unidirectional Piezoelectric Motor Evaluation Kit. (Model: UPM-28) Made in USA

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-122 REV A 12/09

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST. Centrifugal Pump Primer MODEL 6D, HAN-DEE PRIMER

TBM Series 3-Way Ball Valve

Pump Installation and Service Manual HRS Hydromatic Retractable System

Operators Manual. Recirculating Chiller /06/08

Dual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev

15H882 Slider Bearing Kit

Operating and Installation Instructions

CRD600 Automatic Fitting Inserter

Turbine Flow Meter Series Turbine Meter USER MANUAL

Insertion turbine INSTRUCTION SHEET. TECHNICAL PRODUCT

ETF-600 Sensor Operated Lavatory Faucet

Merkur Displacement Pump

GRINNELL MODEL CB800 CIRCUIT BALANCING VALVE INSTALLATION & SETTING HANDBOOK

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

Positive Displacement Flowmeters GM515 series instruction manual

Colt Series C400, C500

WJ-Series. Turbine Meter Instructions ISO. 6 Meter. 3 Meter. Precision Flow Measurement. An ONICON Brand 9001:2008. if ie

Cyclone II. Cyclone. and OPERATOR S MANUAL IMPORTANT- READ OPERATOR S MANUAL BEFORE USE.

Liquid Turbine Flow Meter OwnerÊs Manual

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

AV16, AV26, AV36, AV46, AV56, LH25, LH29, LH35, LV20, LV21, LV35 & LV36 Series Manual

PVDF TURBINE HOUSING

Service Guide JATCO Environmental Protection Tank Model J-7000

½ DODGE CUMMINS OEM BYPASS LIFT PUMP KIT Installation Instructions Part #

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09

Transcription:

Instruction Manual Anderson Instrument Co. Inc. 156 Auriesville Road Fultonville, NY 12072 1-800-833-0081 Fax 518-922-8997 www.anderson-negele.com Instrument Model Number Instrument Serial Number HMP TURBINE FLOWMETER Form Number AIC2056 1/07 Effective: July 2017 Supersedes: March 2007

PAGE 2 Table of Contents Section 1 - Specifications 3 1.1 Environmental Specifications 3 1.2 Operational Specifications 4 Section 2 - Introduction 5 2.1 Description 5 Section 3 - Installation 5 3.1 Location 5 3.2 Installation Illustration 5 Section 4 - Electrical Wiring 6 4.1 Signal Probe Wiring 6 4.2 Wiring Diagram 6 Section 5 - Calibration 7 5.1 K-Factor 7 Section 6 - Maintenance 8 6.1 Disassembly 8 6.2 HM Materials List 8 6.3 Assembly 9 6.4 Rotor Wear 9 6.5 Housing Wear 9 Section 7 - Troubleshooting 10 Section 8 - Warranty and Return Statement 11

PAGE 3 Section 1 - Specifications 1.1 ENVIRONMENTAL SPECIFICATIONS POWER / SIGNAL HTS1000 Supply Voltage: Signal Output: Output Units: Ambient Temperature Range: 8-24 VDC, 0.8 Watts maximum 7.3-23.3 VDC, Unscaled, Pulsed Output Pulses Per Volume -40-79 C (-40-175 F) HT75000 Supply Voltage: Signal Output: Output Units: Ambient Temperature Range: None 0.18-2.6 V.P.P, Unscaled, Frequency Output Pulses Per Volume -54-107 C (-65-225 F) 1.2 OPERATIONAL SPECIFICATIONS RANGE: MODEL METER SIZE SANITARY CLAMP CONNECTION FLOW RANGE HMP100 1 1 26.5-265 LPM (7-70 GPM) HMP150 1-1/2 1-1/2 49-492 LPM (13-130 GPM) HMP200 2 2 94-946 LPM (25-250 GPM) Accuracy: +0.50% of rate Over Entire Flow Range Repeatability: +0.10% Maximum Product Temperature: 149 C (300 F) Maximum Inlet Pressure: 10.3 Bar (150 psi) Maximum Product Viscosity: 100 cps MATERIAL / CONSTRUCTION Housing: Rotor: Gasket: Bearing Sleeve: Adhesive: Process Connection: Ratings: 316L Stainless Steel (R a 20 max) 316L Stainless Steel (R a 20 max) PTFE Polytetrafluoroethylene Rulon 123 (reinforced Polytetrafluoroethylene) GSP 1325-2 (Epoxy Resin) Sanitary Clamp Connections USP Class VI Designed to meet ASME BPE-2004 3-A compliant, Third party verified in accordance with standard 28-03

PAGE 4 FIGURE 1.2 TURBINE DIMENSIONS B A MODEL DIM A DIM B FITTING HMP100 3.25 (82.6mm) 5.88 (149.4mm) 1 T.C. HMP150 3.63 (92.2mm) 6.13 (155.7mm) 1 1/2 T.C. HMP200 3.88 (98.6mm) 8.63 (219.2mm) 2 T.C. CONNECTION TO EXTENSION CABLE PICK-UP PROBE 6 REF. 3/4 NPT FLOW

PAGE 5 Section 2 - Introduction 2.1 DESCRIPTION The HMP is a volumetric turbine flowmeter. As liquid flows through the meter, it causes the rotor to spin. An external non-contact pick-up probe counts each passing vane of the rotor as it spins. Each revolution of the rotor equates to an exact volume of liquid. This digital signal may feed instrumentation such as controllers or digital indicators. The sealed probe and stainless construction meet the demands of damp or wet applications, and may be directly washed down during normal cleanup. Units are shipped pre-calibrated from the factory with a pulse per gallon value identified on the body. Section 3 - Installation 3.1 LOCATION The HMP turbine series flowmeter provides accurate measuring results when installed in either a vertical or horizontal pipe section. Select a location where the meter body will be completely filled with product (see figure 3.2). There must be a rise of pipeline elevation from the outlet side of the meter. Avoid the presence of air, either bulk or entrained, from entering the product as it passes through the flow tube. In a vertical pipe section, install the meter body in the upward direction of flow. In a horizontal pipe section, install the meter body at the lowest possible point of the piping system. Be sure the arrow on the body of the meter points in the direction of flow. Install the meter with a minimum of 10 pipe diameters of straight tubing upstream and 5 pipe diameters of straight tubing downstream. Under normal conditions the meter should be installed in a positive pressure location. When installing the transducer in the meter body, hand tighten the transducer until it bottoms out. DO NOT USE A WRENCH, as you may damage the transducer. Secure the position of the transducer with the hex jam nut. FIGURE 3.2 INSTALLATION A Guidelines Install in a horizontal pipe section at a low point before a rising pipeline to ensure meter body remains full. Installation Illustrations C B Install in a vertical pipe section with an upward direction of flow to ensure meter body remains full. 5 x PIPE DIAMETER MINIMUM B D C D Do not install in a horizontal pipe section located at the highest point of pipeline. This location allows air to accumulate in the flow tube which causes measuring errors. Do not install in a vertical pipe section with a downward direction of flow. This location allows air to accumulate in the meter body which causes measuring errors. 10 x PIPE DIAMETER MINIMUM A 5 x PIPE DIAMETER MINIMUM 10 x PIPE DIAMETER MINIMUM

PAGE 6 Section 4 - Wiring 4.1 SIGNAL PROBE WIRING Always route signal cables separate from AC power and AC control circuits. Signal cables must be shielded with the bare shield drain wire grounded on one end and floating on the other end. NOTE: If it becomes necessary to splice cable connections, be sure to properly solder or join wire connections. Loose connections have the ability to generate false counts. DIAGRAM 4.2 WIRING DIAGRAM ANDERSON INSTRUMENT CO., INC. PART NUMBER HT750000 HMP SERIES TURBINE FLOWMETER FEMALE SOCKET (1) BLACK WIRE HT750000 LENGTH - APPROX. 12'' WHEN THREADED INTO HM SERIES FLOWMETER MALE PIN (3) WHITE WIRE PIN/SOCKET ORIENTATION V HT750000 PICK-UP PROBE SPECIFICATIONS SIGNAL OUT SINE WAVE OPERATIONAL FREQUENCY RANGE 0-1000Hz OUTPUT VOLTAGE.18-2.6 V.P.P. OUTPUT WIRING BLACK WHITE SHIELD ( ) SIGNAL OUTPUT NO POLARITY Hz ANDERSON INSTRUMENT CO., INC. RED + BLK COM WH SIG PART NUMBER HTS1000 HMP SERIES TURBINE FLOWMETER FEMALE SOCKET (1) BLACK WIRE HTS1000 LENGTH - APPROX. 12'' WHEN THREADED INTO HM SERIES FLOWMETER MALE PIN (2) MALE PIN (3) RED WIRE WHITE WIRE PIN/SOCKET ORIENTATION INPUT/OUTPUT WIRING RED (SUPPLY INPUT+8-24VDC) BLACK (COMMON) WHITE (SIGNAL OUTPUT) SHIELD V SIGNAL OUT EXCITATION VOLTAGE OPERATIONAL FREQUENCY RANGE DUTY CYCLE 40% 60% 40% ~ ~ SUPPLY VOLTAGE MINUS 0.7V 0.5V T SQAURE WAVE 8-24 VDC, 0.8 Watt max 0-1000Hz 40 HIGH - 60 LOW

PAGE 7 Section 5 - Calibration The HMP flowmeter signal probe detects motion from the rotor to provide a pulsed output. Due to slight changes in meter dimensions, the volume of liquid displaced by the rotor is not the same for every flowmeter. To account for these changes, each meter is flow tested at the factory. A specific numeric value is determined. This identifies the amount of pulses the meter will output per a fixed volume that passes through it. In the case of Anderson flow products a gallon is the volume. This value is labeled on the meter body as a P/G pulses per gallon, which is also know as a K-Factor. Pulsed output values are normally entered into digital converter as a divider value K-Factor, or as a multiplier value known as a Scale Factor. Either method converts the unscaled pulses of a flowmeter into the desired engineering unit of your choice, such as gallons, tenths of gallons, liters, etc.

PAGE 8 Section 6 - Maintenance The HMP flowmeter, if properly applied, should provide many years of trouble-free service. Excessive flow rates and/or temperature and pressure are conditions which most commonly cause damage to the flowmeter. 6.1 DISASSEMBLY AND INSPECTION Verify that all line pressure is relieved with all valves closed prior to removal of the meter. Disconnect signal cable and completely remove meter body from the product line. Remove clamp and separate meter housings. Place all items on a clean area for inspection. Rotate flow Straighteners until they fall from the meter housing. As components are removed from the housing inspect each piece for visible damage. With the HMP turbine wear is typically isolated to the rotor bearing and shaft. Primarily rotor wear will occur on the inside diameter, or to the downstream side of the bearing. Premature rotor wear is caused by over-ranged flow rates, or abrasive products that would deteriorate the rotor bearing. (Figure 6.4) Housing damage occurs from a worn rotor. The ID of the rotor can wear to a point where the OD will contact the housing. This condition will immediately diminish the performance of the flowmeter. Prolonged operation under these circumstances can permanently damage the meter housing (Figure 6.5). FIGURE 6.2 HM MATERIALS LIST 8 9 7 5 4 3 2 1 FLOW 6 ITEM HMP100 (1 ) HMP150 (1.5 ) HMP200 (2 ) DESCRIPTION 1 HMP-100-1 HMP-150-1 HMP-200-1 METER HOUSING 2 HMP-100-2 HMP150-2 HMP-200-2 GASKET 3 HMP-100-3S HMP-150-3S HMP-200-3S DOWNSTREAM FLOW STRAIGHTENER 4 HMP-100-4S HMP-150-4S HMP-200-4S ROTOR 5 HMP-100-5S HMP-150-5S HMP-200-5S UPSTREAM FLOW STRAIGHTENER 6 36609A0001 36609A0002 36609A0003 CLAMP 7 HMP-100-7 HMP-150-7 HMP-200-7 FLOW STRAIGHTENER HOUSING 8 HTS1000 (3-WIRE PROBE - INCLUDES JAM NUT) PICK-UP PROBE 8a HT75000 (2-WIRE PROBE - INCLUDES JAM NUT) PICK-UP PROBE 9 CABLE-3W-25 (3-WIRE) * EXTENSION CABLE STD. 25 FT. 9a CABLE-2W-25 (2-WIRE) * EXTENSION CABLE STD. 25 FT. * CONSULT ANDERSON FOR OTHER OPTIONAL LENGTHS

PAGE 9 6.3 ASSEMBLY Verify the rotor spins freely on the shaft prior to installation. Rotate parts until they fall into place. Match assembly pieces with the orientation shown. (Figure 6.2) DO NOT FORCE THE PIECES TOGETHER! Be sure the gasket between the meter housings is in the groove of the body connection area. Secure the housing clamp and reinstall in the process line. FIGURE 6.4 ROTOR WEAR NEW ROTOR ROTOR WITH WORN BEARING REPLACE ROTOR NEW ROTOR ROTOR WITH WORN BEARING CHANGE ROTOR TO REVERSE POSITION OR REPLACE ROTOR FIGURE 6.5 HOUSING WEAR ROTOR WEAR

PAGE 10 Section 7 - Troubleshooting HM FLOWMETER TROUBLESHOOTING GUIDE PROBLEM CAUSE ACTION No output or erratic output Failed Probe (no output) Probe not seated Moisture and/or corrosion in probe-to extension cable connector Flow rate too low Obstructed Rotor Incorrect wiring Bad cable splice No scale factor entered Signal interface problem Replace Probe Check probe: must be threaded to bottom Disconnect extension cable at probe for visual check, dry or clean if required Check meter specification for flow range Check rotor (should spin freely) Check manual for correct wiring configuration Check color code and continuity integrity Check readout device scale factor Check signal input specs of receiving device HT75000 Incorrect coil resistence Check black/white signal wires for 975Ω Poor accuracy/ repeatability Air in system Process flow rate out of meter flow range Obstructed Rotor Probe not seated Poor meter installation Poor system hydraulics Incorrect scale factor Electrical noise Changing product characteristics density and/or viscosity Inaccurate proving standard Operating error poor testing method Rotor wear Damaged housing Add air elimination device Check meter specs for flow range info (adjust flow rate or change-out meter) Check rotor (should spin freely) Check probe: must be threaded to bottom Locate meter in low spot (see installation) Backflow? (Install check valve) Valve closing time? Check: scale factor, K factor and unit of measure Check: shielding, separate signal from AC wires Check: product weight, viscosity, scale accuracy, control temp. Multiple products? Verify accuracy of proving standard (vessel/ scale) Observe test procedure Remove and inspect (figure: 6.4) Remove and inspect (figure: 6.5)

PAGE 11 Section 8 - Warranty and Return Statement These products are sold by The Anderson Instrument Company (Anderson) under the warranties set forth in the following paragraphs. Such warranties are extended only with respect to a purchase of these products, as new merchandise, directly from Anderson or from an Anderson distributor, representative or reseller, and are extended only to the first buyer thereof who purchases them other than for the purpose of resale. Warranty These products are warranted to be free from functional defects in materials and workmanship at the time the products leave the Anderson factory and to conform at that time to the specifications set forth in the relevant Anderson instruction manual or manuals, sheet or sheets, for such products for a period of one year. THERE ARE NO EXPRESSED OR IMPLIED WARRANTIES WHICH EXTEND BEYOND THE WARRANTIES HEREIN AND ABOVE SET FORTH. ANDERSON MAKES NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO THE PRODUCTS. Limitations Anderson shall not be liable for any incidental damages, consequential damages, special damages, or any other damages, costs or expenses excepting only the cost or expense of repair or replacement as described above. Products must be installed and maintained in accordance with Anderson instructions. Users are responsible for the suitability of the products to their application. There is no warranty against damage resulting from corrosion, misapplication, improper specifications or other operating condition beyond our control. Claims against carriers for damage in transit must be filed by the buyer. This warranty is void if the purchaser uses non-factory approved replacement parts and supplies or if the purchaser attempts to repair the product themselves or through a third party without Anderson authorization. Returns Anderson s sole and exclusive obligation and buyer s sole and exclusive remedy under the above warranty is limited to repairing or replacing (at Anderson s option), free of charge, the products which are reported in writing to Anderson at its main office indicated below. Anderson is to be advised of return requests during normal business hours and such returns are to include a statement of the observed deficiency. The buyer shall pre-pay shipping charges for products returned and Anderson or its representative shall pay for the return of the products to the buyer. Approved returns should be sent to: ANDERSON INSTRUMENT COMPANY INC. 156 AURIESVILLE ROAD FULTONVILLE, NY 12072 USA ATT: REPAIR DEPARTMENT

ANDERSON INSTRUMENT CO., INC 156 AURIESVILLE RD. FULTONVILLE, NY 12072 USA 800-833-0081 FAX 518-922-8997 ANDERSON INSTRUMENT CO. LP 400 BRITANNIA RD. EAST, UNIT 1 MISSISSAUGA, ONTARIO L4Z 1X9 CANADA 905-568-1440 FAX 905-568-1652 NEGELE MESSTECHNIK GmbH (A Division of Anderson) RAIFFEISENWEG 7 D-87743 EGG A. D. GÜNZ GERMANY +49 (0) 8333/9204-0 FAX +49 (0) 8333/9204-49 www.anderson-negele.com