Diesel Generating Set 315KW / 394KVA 280KW / 350KVA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

Similar documents
Diesel Generating Set 300KW / 375KVA 275KW / 344KVA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

Diesel Generating Set 520KW / 650KVA NA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

Diesel Generating Set

Standby Power(60Hz) Prime Power(60Hz) 1000KW / 1250KVA 900KW / 1125KVA. Standard Features

FE - C KW / 650KVA 600KVA

Technical Data 280KW / 350KVA 256KW / 320KVA. Bargh Afshan Alborz. Standby Power(50Hz) Prime Power(50Hz) General Features:

Standby Power(60Hz) Prime Power(60Hz) 513KW / 642KVA 456KW / 570KVA. Standard Features

Diesel Generating Set

Diesel Generating Set 286KW/358KVA 260KW/325KVA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

Standby Power(60Hz) Prime Power(60Hz) 170KW / 212KVA 160KW / 200KVA. Standard Features

Diesel Generating Set. Generator Ratings

Technical Data 1600KW / 2000KVA 1450KW / 1813KVA. Bargh Afshan Alborz. Standby Power(50Hz) Prime Power(50Hz)

Diesel Generating Set

Diesel Generating Set

CGT Stamford UCI 274 E1

Dual Frequency Diesel Genset

Prime Ratings (KW/KVA) 400/ / / /910

POWERED BY DOOSAN DIESEL GENERATOR SET

Weifang Ricardo Generator

DW Series Generator. Specification BV-DW145

Voltage kva kw kva kw Amp 400/ ,00 88,00 100,00 80,00 144,00

LSC500S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 500 KW 400. Standby Power

SIVASA Doosan Series. SD250 Technical Data

PGCLS Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

Voltage adjusting range % Transient voltage deviation(100% load sudden reduce) +20% Transient voltage deviation(load impact)

CUMMINS 30KVA. Voltage kva kw kva kw Amp 400/230 30,00 24,00 27,00 21,60 38,00

Prime 60Hz 155 kw / 193 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

TPD2250H6.3 TECHNICAL DATA

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

UQ-Power Diesel Generator Set. Model: PE-91 GENERAL DATA. kw/kva Prime Power Continuous. kw/kva Standby power. kw/kva

DIESEL GENSET. Prime 60Hz 91 kw / 114 kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Prime 60Hz 36 kw / 45 kva

DIESEL GENSET. Prime 60Hz 55 kw / 68 kva

Prime 60Hz 455 kw / 568 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

GMS350C/S EC Series. Features:

Voltage kva kw kva kw Amp 400/ ,00 160,00 180,00 144,00 259,00

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Prime 60Hz 273 kw / 341 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

GKP 550KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

PGDLS352KW 380/ / / / / / / / /

Prime 60Hz 18 kw / 18 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings Prime Ratings kw/kva 240MONO / / 18

PGDLS / / / / / / / / /

ENGINE DATA. 205L/s [434cfm] 565 C [1049 F] 750mm CE [30in. WG

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings 1 kw/kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings 1 kw/kva

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

GKP 660KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

Rating Definitions and Conditions

PGPLS215Kw. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

PGDLS / / / / / / / / /

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

PGKT / / / / / / / / / / / /

Diesel generator set QSK23 series engine

DIESEL GENSET. Prime Hz 16 kw / 20 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Prime Hz 400 kw / 500 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Voltage adjusting range % Voltage stabilization time(100% load sudden reduce) 3. Voltage fluctuation rate: Frequency volatility ±0.

Diesel generator set QSX15 series engine

TM20UCM MODEL. Standard Features. Generator Ratings. Conditions of sale. Prime Hz 18 kw / 18 kva. General features :

Diesel generator set. QSB5 series engine Hz EPA Tier 3 emissions. Specification sheet. Description. Features

BC DIESEL GENERATORS TECHNICAL DATA DIESEL GENERATING SET 60HZ

PGDLS200. Overall Dimensions (mm) & Weight (kg) Length:3900. Width:1140. Height: 1850

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

Diesel generator set 6BT5.9 series engine

Diesel generator set. 50 kw - 60 kw EPA emissions stationary Standby. Specification sheet. Description. Features

WPS150/S EP Series. Features:

PGPLS10. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

Diesel generator set. 20 kw EPA emissions stationary Standby. Specification sheet. Description. Features

Diesel generator set QSK78 series engine

Model MP150 W W

DIESEL GENERATOR DATA SHEET

Model NA 2 L

WPS20/S EP Series. Features:

Powered by Cummins Model:YN-95C

Spark-ignited generator set

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized

WPS60/S EP Series. Features:

Rating Definitions and Conditions

Diesel generator set QSK50 series engine

Industrial Diesel Generator Set KD1250-UE 60 Hz - Emission Optimized EPA Tier 2 Certified

Spark-ignited generator set

Diesel generator set QSK23 series engine

Voltage adjusting range % Transient voltage deviation(100% load sudden reduce) +20% Transient voltage deviation(load impact)

WPS100/S EP Series. Features:

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

Diesel generator set QSK78 series engine

Rating Definitions and Conditions

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

Diesel generator set QSB7 series engine

Diesel generator set QSL9-G7 series engine

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

WPS350/S EP Series. Features:

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

GMS200C/S EC Series. Features:

Transcription:

MODEL Standby Power(50Hz) Prime Power(50Hz) 315KW / 394KVA 280KW / 350KVA Standard Features General Features: Engine ( CCEC Cummins NTA855-G4 ) Radiator 40 O C max, fans are driven by belt, with safety guard 24V charge alternator Alternator(STAMFORD HCI444E1), single bearing alternator IP23, insulation class H/H Absorber Dry type air filter, double fuel filter, oil filter, coolant filter Main line circuit breaker Standard control panel Two12V batteries, rack and cable Ripple flex exhaust pipe, exhaust siphon, flange, muffler User manual Generator Ratings Voltage HZ Phase P.F (COS ) Standby Amps Standby Ratings (KW/KVA) Prime Ratings (KW/KVA) 440/254 50 3 0.8 517 315/394 280/350 415/240 50 3 0.8 548 315/394 280/350 400/230 50 3 0.8 568 315/394 280/350 380/220 50 3 0.8 598 315/394 280/350 Prime Power (PRP): Prime power is available for an unlimited number of annual hours in variable load application, in accordance with GB/T2820-97(eqvISO8528); A 10% overload capability is available for a period of 1 hour within a 12-hour period of operation. Standby Power Rating (ESP): The standby power rating is applicable for supplying emergency power for the duration of a utility power interruption. No overload, utility parallel or negotiated outage operation capability is available at this rating. Sales Promises Baifa Power provides a full line of brand new and high quality products. Each and every unit is strictly factory tested. Warranty is according to our standard conditions: 12 months or 1,000 running hours, subject to the earlier one. Service and parts are available from Baifa Power or distributors in your location. Specifications may change without notice 1/5

ENGINE DATA Manufacturer / Model: CCEC Cummins NTA855-G4, 4-cycle Air Intake System: Turbo, Water/Air cooling Fuel System: PT type fuel pump, EFC Cylinder Arrangement: 6 in line Displacement: 14L Bore and Stroke: 140 152(mm) Compression Ratio: 14.0:1 Rated RPM: 1500rpm Max. Standby Power at Rated RPM: 351KW/477HP Governor Type: Electronic Frequency Regulation, Steady State: 1.5% Exhaust System Exhaust Gas Flow: 1225L/s Exhaust Temperature: 541 Max Back Pressure: 10.1kPa Air Intake System Max Intake Restriction: 6.2kPa Consumption: 434L/s Intake Flow: 9650L/s Fuel System 110%(Standby Power) Load: 79.5L/h 100%(Prime Power) Load: 70.7L/h Total Fuel Flow: 375L/h Oil System Total Oil Capacity: 38.6L Oil Consumption: 0.24L/h Engine Oil Tank Capacity: 34.1L Oil Pressure at Rated RPM: 241-345kPa Cooling System Total Coolant Capacity: 63.9L Thermostat: 82-93 Max Water Temperature: 104 Specifications may change without notice 2/5

ALTERNATOR SPECIFICATION GENERAL DATA Compliance with GB755, BS5000, VDE0530, NEMAMG1-22, IED34-1, CSA22.2 and AS1359 standards. Alternator Data Manufacturer / Type: STAMFORD / HCI 444E1 Number of Phase: 3 Connecting Type: 3 Phase and 4 Wires, Y type connecting Number of Bearing: 1 Power Factor: 0.8 Protection Grade: IP23 Altitude: 1000m Exciter Type: Brushless, self-exciting Insulation Class, Temperature Rise: H/H Telephone Influence Factor (TIF): <50 THF: <2% Voltage Regulation, Steady State: ±1% Alternator Capacity: 350KVA Alternator Efficiencies: 93.3% Air Cooling Flow: 0.486m 3 /s GENERATING SET DATA Voltage Regulation: Voltage Regulation, Stead State: Sudden Voltage Warp (100% Sudden Reduce): Sudden Voltage Warp (Sudden Increase): Voltage Stable Time (100% Sudden Reduce): Voltage Stable Time (Sudden Increase) Frequency Reduce: Frequency Regulation, Stead State: Frequency Waving: Sudden Frequency Warp (100% Sudden Reduce): Sudden Frequency Warp (Sudden Increase): Frequency Recovery Time (100% Sudden Reduce): Frequency Recovery Time (Sudden Increase): Emission Level: ±5% ±1% +25% -20% 6S 6S 5% Adjustable 1.5% 0.5% +12% -10% 5S 5S Euro I Specifications may change without notice 3/5

Options Engine Fuel System Control System Heater Daily Fuel Tank Auto Control Panel Battery Charger Base Fuel Tank Remote Control Panel Water Separator Auto Transfer Switch (ATS) Control Panel Paralleling System Electricity Output Cabinet Alternator Others Data Anti Condensation Heater Soundproof Type Engine Parts Drawing List Permanent Magnet Trailer Type Spare Parts Generator(PMG) Drop CT(For Paralleling) Dimension & Weight B a i f a P o wer B a i f a P o w e r Standard Configuration (Open Type) Overall Size: 3030(mm) 1100(mm) 1850(mm) Weight: 2950kg With Base Fuel Tank Overall Size:3030(mm) 1100(mm) 1900(mm) Weight: 3150kg Soundproof Type Overall Size: 4230(mm) 1440(mm) 2200(mm) Weight: 3800kg Specifications may change without notice 4/5

Standard Control Panel Baifa Standard Control Panel is the basic configuration for normal operation and usage, it is of some advantages such as easy to operate, various function and well protection. Operative buttons such as Turn On, Per-heat, Starting, Stop (Emergency Stop) on the panel. While malfunction occurs, control panel will stop the generator and also alarm with light or buzz. Auto Module Control Panel Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu. Features: MRS10-can receive remote output signal from ATS and realize auto start and stop of generators. MRS16-can realize all functions of MRS10, add RS232 interface which can communicate with PC to realize remote operation. AMF25-Auto Mains Failure controller, can realize all functions of MRS16, furthermore can detect ATS and control directly. Auto Parallel Control Panel Automatic Parallel Control Panel This new automatic parallel system adopts Comap series intelligent modules, inserted and folded installed, no need the peripheral relay and logic circuit. The main switch adopts ABB electronic breaker or frame breaker, combined together with the generator, which is very reliable. One generator, one panel. The panel can be used both for singly and parallel. It is only need to parallel generator with such panel when the capability needs to be enlarged in the future. Specifications may change without notice 5/5