Pressure sensors - Nautilus

Similar documents
XMLR400M1N26 Pressure sensors XMLR 400bar - 1/4" 18 NPT - 24VDC ma - NPN - M12

XMLRM01G1P25 Pressure sensors XMLR -1 bar - G 1/4-24VDC ma - PNP - M12

XMLR400M1N75 Pressure sensors XMLR 400bar - G 1/4-24VDC V - NPN - M12

Electronic pressure sensors OsiSense XM For control circuits

XMLR160M2P05 Pressure sensors XMLR 160bar - G 1/4-24VDC - 2xPNP - M12

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.

XMLA002A2C11 pressure switch XMLA 2.5 bar - fixed scale 1 threshold - 1 C/O

Electronic Pressure Switch EDS 3000

XMLB300D2C11 pressure switch XMLB 300 bar - adjustable scale 2 thresholds - 1 C/O

9012G Pressure and 9016G Vacuum Switches

Ultrasonic sensors OsiSense XX Cylindrical plastic case, M12 x 1, M18 x 1, M30 x 1.5 DC supply, solid-state output

Proximity, Photoelectric, and Ultrasonic Sensors, Limit Switches, Pressure Sensors, Machine Safety, Encoders, RFID, and Machine Cabling

Paddle-wheel flow controller with optical principle for On/Off control

XMLB020A2S13 pressure switch XMLB 20 bar - adjustable scale 2 thresholds - 1 C/O

Paddle-wheel flow controller for On/Off control

Paddle-wheel flow controller for On/Off control

Industrial Pressure Transmitters

OEM Pressure Transmitters

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

Positive displacement batch controller

XMLA160D2S11 pressure switch XMLA 160 bar - fixed scale 1 threshold - 1 C/O

Type A-10 General Purpose Pressure Transmitters

XCKP2145P16 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - M16

Limit switches 3. Page 92. Page 92

XACA871 pendant control station XAC-A - 8 pushbuttons

XXV18B1PAL2 Ultrasonic sensor - M18 metal - Sn 50mm - PNP NO - cable 2m

SSI Technologies Application Note PS-AN7 MediaGauge (Model MG-MD) Digital Pressure Gauge Product Overview

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Insertion magnetic inductive flowmeter

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A

Components for safety applications

Pressure transmitters for heavy duty applications MBS 8200 and MBS 8250

Inductive conductivity meter

Type A-10 General Purpose Pressure Transmitter

OEM Pressure Transmitters

3 - Protection components Motor circuit-breakers

Conductivity meter. PLC Solenoid valve. Type Type On/Off Diaphragm valve. Valve islands

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

Electronic pressure switch with two switching outputs

Electronic Temperature Sensor ETS 300

Photoelectric Sensors 55 Series

INSERTION flowmeter with paddle wheel, ELEMENT design

Electronic pressure switch. Type HEDE 10. Contents. Features. RE Edition: Replaces:

RVS-DX Digital Reduced Voltage Motor Starter

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050

ILE1F661PC1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox

CTE7000 / CTU7000 Series Miniature pressure transmitters

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

Soliphant T FTM260. Technical Information. Level limit switch Cost-effective vibration limit switch for fine-grained solids

JUMO dtrans p35. Pressure Sensor with IO-Link. Application. Brief description. Customer benefits. Special features

Parker Hannifin GmbH & Co. KG Tube Fittings Division Europe Am Metallwerk 9, Bielefeld Phone Fax

Essential equipment for all your requirements

Electronic flow switch With display, for liquid media Model FSD-3

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

The right choice for your application. Pressure sensors from ifm.

Type E-10, E-11 Hazardous Area Explosion-proof Transmitters

Electronic Pressure Switches

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Limit switches. 6 Thermoplastic roller lever 1 direction of actuation SEN TRONIC AG. Presentation

SIRIUS 3RU2 Thermal Overload Relays

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch 25 M ISE30 01 ZSE M. How to Order. For positive pressure

2SGT. Electronic Pressure Instrument. Three Separate Functions in a Single Loop-Powered Device

XT130B1NAL2 capacitive sensor - XT1 - cylindrical M30 - brass - Sn 10 mm - cable 2 m

SECTION 6 VACUSTAT, PRESSURE SENSORS, VACUUM SENSORS, & FILTERS

Relative and absolute pressure transmitter type 691

ILE2K661PC1A1 brushless dc motor V- EtherNet/IP interface - L = 174 mm- 18:1

INSTRUMENTATION & CONTROL

XACA871 pendant control station XAC-A - 8 pushbuttons

RVS-DN Digital Reduced Voltage Motor Starter

Electronic Pressure Switches

Max. oil content of compressed air Shock resistance max. (XYZ direction) Vibration resistance (XYZ direction) Quiescent current consumption

Max. oil content of compressed air Shock resistance max. (XYZ direction) Vibration resistance (XYZ direction) Quiescent current consumption

Pressure transmitter for industrial applications Type MBS 4500

XB5AD33 SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS

ILA2D572TC1F0 integrated drive ILA with servo motor V - DeviceNet - indus connector

Differential pressure sensor

RUMC22F7 universal plug-in relay - Zelio RUM - 2 C/O V AC - 10 A - with LED

Adjustment range. Seal material. Pressure connection

Commercial Pressure and Float Switches for Power Circuits Catalog 9034CT9701R01/11 Class 9013, 9036, 9037, 9038

Inductive Proximity Sensor

The Complete System Solution! Highest Grade Electronic Components RoHS Compliant.

Operating Instructions for Pressure Transmitter with Digital Display. Model: PDA

Inductive conductivity meter

ECONOMISER SERIES E2T USER MANUAL

Cat N 3. OVERALL DIMENSIONS

TURCK Inc Campus Drive Minneapolis, MN Application Support: Fax: (763) M2

Model Pressure range ON/OFF output Linear output

Operating Instruction for Electronic Pressure Switch. Model: PDD

10 Pressure/temperature measurement SCPT analogue

Positive displacement flowmeter

OsiSense XMLP Pressure Transmitters for Industrial Applications. Catalog

OEM relative pressure transmitter type 506

Electronic pressure switch with integrated analogue output

Signet Pressure Transmitter

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Speed Sensor. Inputs: Safety Information. Outputs. Wiring Diagram. Electrical Data: NOTICE

Transcription:

: pages / to /5 Presentation Presentation sensors type XML-F are characterised by their ceramic pressure measuring cell. They are for pressure control of hydraulic oils, fresh water, sea water, air and corrosive fluids at pressures up to 00. Digital display for programming codes, parameter values and indication of measured pressure. LED indicator(s) for providing status of pressure switch (s) Output Output Bar Psi 3 3 LED indicators for pressure unit of measurement selected ( or psi) Menu 4 4 Enter 4 Selection keypads for the various functions and for setting parameters Three menus enable the user to : - configure ( PROG menu) the various functions of the pressure sensors (and also, to access the USER menu detailed below), - perform ( USER menu) diagnostic operations and, for pressure switches, to set the switching point pressure values, - read ( READ menu) all the configuration details, together with the values set in the PROG and USER menus. Functions Analogue pressure sensors iiidii have an analogue, either 4 0 ma or 0 0 V. In addition to having a manual diagnostic function (see below), they also incorporate a digital input which provides a remote autotest function by connection to a PLC. When the product is operating correctly, the analogue must, when testing, be close to 50 % of the unit size. The diagnostic function is also accessible manually. Electronic pressure switches iiidii are pressure switches with an adjustable differential, for regulation between thresholds, featuring a solid state (programmable both for NPN or PNP and NO or NC) and a 4 0 ma or 0 0 V analogue. They incorporate the manual diagnostic function (see below). Electronic pressure switches iiidi3i are dual stage switches, with adjustable differential for each threshold, featuring solid state s (programmable both for NPN or PNP and NO or NC). They incorporate the manual diagnostic function (see below). Electronic pressure switches for a.c. control iiiei4i are switches with adjustable differential, for regulation between thresholds, featuring an c.5 A relay (programmable for NO or NC). They incorporate the manual diagnostic function (see below). Sensors type XML-F feature : i Various configurable functions For the display : - pressure unit of measurement ( or psi), - response time (slow : display refreshes in % steps of the units size, normal : display refreshes in 0.5% steps of the units size or fast : display refreshes every 0 ms). For the analogue : - response time (adjustable from 5 to 500 ms, in steps of 0 ms), - maximum pressure of the curve (adjustable from 75 to 5% of the units size). For each solid state : - PNP or NPN logic, - NO or NC, - time delay both on trip and on reset (adjustable from 0 to 50 s), - response time (adjustable from 5 to 500 ms, in steps of 0 ms). For the a.c. via relay : - NO or NC, - time delay both on trip and on reset (adjustable from 0 to 50 s), - response time (adjustable from 5 to 500 ms, in steps of 0 ms). i Manual diagnostic function enabling : - checking correct operation of sensor - reading the value of the maximum pressure peak that has occurred since the last reset to zero and also, deleting this value for a fresh reset. /0 Te

: pages / to /5 Characteristics Environment Conforming to standards è, IEC/EN 0947-, IEC/EN 0947-5-, EN 5008, EN 5008, EN 000--, EN 000-4-/3/4/5//8/ Product certification UL, CSA Protective treatment Standard version TC Ambient air temperature C Operation : - 5 + 80 (d.c. models) and - 5 + 75 (a.c. models) Fluids or products controlled Hydraulic oils, air, fresh water, sea water, corrosive fluids, from - 5 to + 80 C Component materials of switch in contact with the fluid Operating position Stainless steel fluid entry, viton seal All positions Vibration resistance 5 gn (5 00 Hz) and 35 gn (0 000 Hz), conforming to IEC 8-- Shock resistance 50 gn, conforming to IEC 8--7 Electrical protection Against reverse polarity, short-circuit, overload and connection faults Degree of protection IP 7 conforming to IEC/EN 059, NEMA 4///3 Operating rate Hz < 50 Output response time ms Adjustable from 5 to 500, in steps of 0 ms Service life op. > 0 million cycles Precision Accuracy Of the zero point : < ± 0.% of the measuring range/ C Of the sensitivity : < ± 0.03% of the measuring range/ C % of the measuring range Repeat accuracy 0.5 % of the measuring range Display response time Fluid connections Electrical connections Adjustable. 3 options : slow (% of the units size), normal (0.5% of the units size) or fast (refreshed every 0 ms) /4" BSP (female), /4" NPT (female) or SAE 7/-0UNF available, depending on model. Please call our Customer information centre on 0870 08808 for full information. M, Snap-C compatible, connector or SAE 7/8-UN connector, depending on model. Te /

page / and vacuum switches Size - (- 4.5 psi), characteristics Vacuum switches with adjustable differential. Solid state and analogue s () Adjustable range of switching - 0.07 - (-.0-4.5 psi) point () () 4-0 ma 0-0 V 4-0 ma 0-0 V Fluid connection /4" BSP female XML-FM0D05 XML-FM0D5 XML-FM0D05 XML-FM0D5 () Weight (kg) 0.480 0.480 0.480 0.480 Complementary characteristics not shown under general characteristics (page /) Possible differential Min. at low and high setting : 0.0 (0.9 psi) (add to to give ) Max. at low setting : 0.95 (3.77 psi) 3 (43.5 psi) 5 (7.5 psi) a 4 V a 7 33 V delay from 0 to 50 s, in steps of second Switching capacity 00 ma 4 0 ma or 0 0 V, depending on model. Maximum signal level adjustable between - 0.5 & 0.5 (- 3. & 3. psi) Electrical connection M, 4 contact, male connector. For suitable female connectors and extension cables, see page / Vacuum switch operating curves 0 ma - 0 V -0,98-0,5-0,05 0-0,07 ma - 5 V Maximum differential Vacuum - - 0,50-0,5 0 0,5 - Minimum differential () Vacuum switches with adjustable differential for regulation between thresholds. These switches incorporate a separate analogue. () Fluids controlled : hydraulic oils, fresh water, sea water, air, corrosive fluids, from - 5 to + 80 C. Refer to component materials of switch in contact with the fluid, page /. Check the compatibility of the switch for the fluid to be controlled (compatibility tables shown on pages /0 to /9). / Te -0,5

page / and pressure switches Size 0 (45 psi), characteristics switches with adjustable differential. Solid state and analogue s () Adjustable range of switching 0.7 0 (0.5 45 psi) point () () 4-0 ma 0-0 V 4-0 ma 0-0 V Fluid connection /4" BSP female XML-F00D05 XML-F00D5 XML-F00D05 XML-F00D5 () Weight (kg) 0.480 0.480 0.480 0.480 Complementary characteristics not shown under general characteristics (page /) Possible differential Min. at low and high setting : 0. (.9 psi) (subtract from to give ) Max. at high setting : 9.5 (37.75 psi) 40 (580 psi) 0 (870 psi) a 4 V a 7 33 V delay from 0 to 50 s, in steps of second Switching capacity 00 ma 4 0 ma or 0 0 V, depending on model. Maximum signal level adjustable between 7.5 &.5 (08.75 & 8.5 psi) Electrical connection M, 4 contact, male connector. For suitable female connectors and extension cables, see page / switch operating curves 0 ma - 0 V 0 ma - 5 V 5 0 5 7,5 0,5 Maximum differential 0,7 Minimum differential 0 0,5 5 9,8 () switches with adjustable differential for regulation between thresholds. These switches incorporate a separate analogue. () Fluids controlled : hydraulic oils, fresh water, sea water, air, corrosive fluids, from - 5 to + 80 C. Refer to component materials of switch in contact with the fluid, page /. Check the compatibility of the switch for the fluid to be controlled (compatibility tables shown on pages /0 to /9). / Te

page / and pressure switches Size 40 (580 psi), characteristics switches with adjustable differential. Solid state and analogue s () Adjustable range of switching.8 40 (40. 580 psi) point () () 4-0 ma 0-0 V 4-0 ma 0-0 V Fluid connection /4" BSP female XML-F040D05 XML-F040D5 XML-F040D05 XML-F040D5 () Weight (kg) 0.500 0.500 0.500 0.500 Complementary characteristics not shown under general characteristics (page /) Possible differential Min. at low and high setting : 0.8 (. psi) (subtract from to give ) Max. at high setting : 38 (55 psi) 0 (30 psi) 40 (3480 psi) a 4 V a 7 33 V delay from 0 to 50 s, in steps of second Switching capacity 00 ma 4 0 ma or 0 0 V, depending on model. Maximum signal level adjustable between 30 & 50 (435 & 75 psi) Electrical connection M, 4 contact, male connector. For suitable female connectors and extension cables, see page / switch operating curves 0 ma - 0 V 40 ma - 5 V 0 0 0 30 40 50 30 0 0,8 0 0 0 30 39, Maximum differential Minimum differential () switches with adjustable differential for regulation between thresholds. These switches incorporate a separate analogue. () Fluids controlled : hydraulic oils, fresh water, sea water, air, corrosive fluids, from - 5 to + 80 C. Refer to component materials of switch in contact with the fluid, page /. Check the compatibility of the switch for the fluid to be controlled (compatibility tables shown on pages /0 to /9). / Te

page / switches with adjustable differential and dual stage pressure switches Size 40 (580 psi), characteristics switches with adjustable differential and relay () Dual stage adjustable pressure switches with solid state s () Adjustable range of switching.8 40 (40. 580 psi).8 40 (40. 580 psi) point(s) ( or & ) () Fluid connection /4" BSP female XML-F040E045 XML-F040D035 (3) Weight (kg) 0.0 0.500 Complementary characteristics not shown under general characteristics (page /) Possible differential (subtract from : Min. at low and high setting : 0.8 (. psi) For each stage : - to give Max. at high setting : 38 (55 psi) Min. at low and high setting : 0.8 (. psi) - & to give & ) Max. at high setting : 38 (55 psi) 0 (30 psi) 40 (3480 psi) c 0 V a 4 V c 0 3 V a 7 33 V Current consumption 3 ma 80 ma Output Relay Programmable NPN or PNP and NO or NC delay from 0 to 50 s, in steps of second Switching capacity.5 A, AC-5, C300 (0 V -.5 A) 00 ma SAE 7/8-UN, 5 contact, male connector. M, 4 contact, male connector. For suitable female Electrical connection For suitable female connectors, see page / connectors and extension cables, see page / switch operating curves (curve for each stage for dual stage pressure switches) switches with relay Dual stage pressure switches 40 30 0 0,8 0 0 0 30 39, Maximum differential Minimum differential () switches with adjustable differential for regulation between thresholds. Relay. () switches with adjustable stages and adjustable differential for each threshold. Solid state s. (3) Fluids controlled : hydraulic oils, fresh water, sea water, air, corrosive fluids, from - 5 to + 80 C. Refer to component materials of switch in contact with the fluid, page /. Check the compatibility of the switch for the fluid to be controlled (compatibility tables shown on pages /0 to /9). Te /3

page / and pressure switches Size 00 (450 psi), characteristics switches with adjustable differential. Solid state and analogue s () Adjustable range of switching 7 00 (0.5 450 psi) point () () 4-0 ma 0-0 V 4-0 ma 0-0 V Fluid connection /4" BSP female XML-F00D05 XML-F00D5 XML-F00D05 XML-F00D5 () Weight (kg) 0.500 0.500 0.500 0.500 Complementary characteristics not shown under general characteristics (page /) Possible differential Min. at low and high setting : (9 psi) (subtract from to give ) Max. at high setting : 95 (377.5 psi) 400 (5800 psi) 00 (8700 psi) a 4 V a 7 33 V delay from 0 to 50 s, in steps of second Switching capacity 00 ma 4 0 ma or 0 0 V, depending on model. Maximum signal level adjustable between 75 & 5 (087.5 & 8.5 psi) Electrical connection M, 4 contact, male connector. For suitable female connectors and extension cables, see page / switch operating curves 0 ma - 0 V 00 ma - 5 V 50 0 50 75 00 5 Maximum differential 7 Minimum differential 0 5 50 98 () switches with adjustable differential for regulation between thresholds. These switches incorporate a separate analogue. () Fluids controlled : hydraulic oils, fresh water, sea water, air, corrosive fluids, from - 5 to + 80 C. Refer to component materials of switch in contact with the fluid, page /. Check the compatibility of the switch for the fluid to be controlled (compatibility tables shown on pages /0 to /9). / Te

page / and pressure switches Size 400 (5800 psi), characteristics switches with adjustable differential. Solid state and analogue s () Adjustable range of switching 8 400 (40 5800 psi) point () () 4-0 ma 0-0 V 4-0 ma 0-0 V Fluid connection /4" BSP female XML-F400D05 XML-F400D5 XML-F400D05 XML-F400D5 () Weight (kg) 0.590 0.590 0.590 0.590 Complementary characteristics not shown under general characteristics (page /) Possible differential Min. at low and high setting : 8 ( psi) (subtract from to give ) Max. at high setting : 380 (550 psi) 00 (7,400 psi) 800 (,00 psi) a 4 V a 7 33 V delay from 0 to 50 s, in steps of second Switching capacity 00 ma 4 0 ma or 0 0 V, depending on model. Maximum signal level adjustable between 300 & 500 (4350 & 750 psi) Electrical connection M, 4 contact, male connector. For suitable female connectors and extension cables, see page / switch operating curves 0 ma - 0 V 400 300 ma - 5 V 00 00 0 00 00 300 400 500 Maximum differential 8 Minimum differential 0 0 00 00 300 39 () switches with adjustable differential for regulation between thresholds. These switches incorporate a separate analogue. () Fluids controlled : hydraulic oils, fresh water, sea water, air, corrosive fluids, from - 5 to + 80 C. Refer to component materials of switch in contact with the fluid, page /. Check the compatibility of the switch for the fluid to be controlled (compatibility tables shown on pages /0 to /9). / Te

page / and pressure switches Size 00 (8700 psi), characteristics switches with adjustable differential. Solid state and analogue s () Adjustable range of switching 4 00 (09 8700 psi) point () () 4-0 ma 0-0 V 4-0 ma 0-0 V Fluid connection /4" BSP female XML-F00D05 XML-F00D5 XML-F00D05 XML-F00D5 () Weight (kg) 0.590 0.590 0.590 0.590 Complementary characteristics not shown under general characteristics (page /) Possible differential Min. at low and high setting : (74 psi) (subtract from to give ) Max. at high setting : 570 (85 psi) 00 (7,400 psi) 800 (,00 psi) a 4 V a 7 33 V delay from 0 to 50 s, in steps of second Switching capacity 00 ma 4 0 ma or 0 0 V, depending on model. Maximum signal level adjustable between 450 & 750 (55 & 0,875 psi) Electrical connection M, 4 contact, male connector. For suitable female connectors and extension cables, see page / switch operating curves 0 ma - 0 V 00 400 ma - 5 V 00 0 00 450 00 750 Maximum differential 4 Minimum differential 0 30 00 400 588 () switches with adjustable differential for regulation between thresholds. These switches incorporate a separate analogue. () Fluids controlled : hydraulic oils, fresh water, sea water, air, corrosive fluids, from - 5 to + 80 C. Refer to component materials of switch in contact with the fluid, page /. Check the compatibility of the switch for the fluid to be controlled (compatibility tables shown on pages /0 to /9). /4 Te

of accessories Replacement parts Description Reference Weight kg Transparent cover XML-ZL007 0.00 with legends Cabling accessories XML-ZL007 Description Length of cable Reference Weight kg Pre-wired M, straight, m XZ-CP4L 0.5 female connector 5 m XZ-CP4L5 0.70 XZ-CP4Li 0 m XZ-CP4L0 0.50 Pre-wired M, elbowed, m XZ-CP4L 0.5 female connector XZ-CP4Li 5 m XZ-CP4L5 0.70 XZ-CP74Li 0 m XZ-CP4L0 0.50 Pre-wired 7/8" UN, straight, m XZ-CP74L 0.85 female connector 5 m XZ-CP74L5 0.40 0 m XZ-CP74L0 0.900 XZ-CCFDM40V M Snap-C, straight, XZ-CCFDM40V 0.50 female connector () XZ-CR504Ci M-M jumper cables Straight m XZ-CR504C 0.05 with straight male connector, female for splitter box connector m XZ-CR504C 0.095 Elbowed m XZ-CR504C 0.05 female connector m XZ-CR504C 0.095 XZ-CR504Ci / Te () Connector incorporating IDCs (Insulation Displacement Connectors) for simple and quick direct, in-line, connection to cable, without the need of a screwdriver or soldering iron.

Dimensions, schemes : pages / to /5 Dimensions iiidiii M x 5 88 9 4 3 0 38 iiieiii 58 () 4 () Female fluid entry iiidii ii5 : /4" BSP For /4" NPT or SAE 7/-0UNF, please call our Customer information centre on 0870 08808. 7/8" UN 5 88 4 9 38 58 () 4 () Female fluid entry iiieii ii5 : /4" BSP For /4" NPT or SAE 7/-0UNF, please call our Customer information centre on 0870 08808. Connector schemes (pressure sensor connector pin view) iiid0i, Fiii iiidi iiid0i, Fiii iiidi iiid03i iiie04i Calibration shunt + 4 3 Analogue Solid state + 4 3 Analogue st stage solid state + 4 3 nd stage solid state Relay 4 3 5 Te /7