KOBOLD KSK FLOWMETER. User Instructions

Similar documents
KOBOLD DAA FLOW INDICATOR. User Instructions. DAA_manual_12-13

KOBOLD DF-MA Flow Transmitter. User Instructions

KOBOLD DF-WM Flow Monitor. User Instructions

KOBOLD SV FLOWMETER/SWITCH. User Instructions

KOBOLD VKA FLOWMETER/SWITCH. User Instructions. Manual-VKA_03-04

ZDM Positive Displacement Flow Meter User Instructions

Operating Instructions for Plastic Flow Meter. Model: KSK

DW PADDLE-BELLOWS FLOWMETER & SWITCH

DW PADDLE-BELLOWS FLOWMETER & SWITCH

PFS Rotameter. Variable Area Flowmeter. Instruction Manual PFS-RM200, RM230, RM250

DW PADDLE-BELLOWS FLOWMETER & SWITCH

KEL DIFFERENTIAL PRESSURE FLOWMETERS

DPT TARGET TYPE FLOWMETERS

Distributed by: M&M Control Service, Inc Installation Instructions F-440N

Installation Instructions F-440N. Model No. F F F F F F F /16 157mm. Inline.

HAYWARD FLOW CONTROL TBH SERIES TRUE UNION BALL VALVE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Operating Instruction for Flowmonitor. Model: DF-WM

KDM ARMORED FLOW METER & SWITCH

Technical Data. Flow Meter Schwertberg, Poneggenstr. 5 Austria/Europe Fax +43/7262/ Tel.

PMG MAGNETIC FLOWMETER

Plastic tube variable area flowmeter for liquids and gases

Operating Instructions for Oval Wheel Flowmeter. Model: DOC

Quality Since 1980 SERVICE GUIDE. VecTac VT EDrive Actuators, Inc. #FB6060 Linear Actuators

100 Series Flow Switches Technical Reference Manual

introduction < STANDARDS >

FIXED DEPTH INSERTION METER INSTRUCTIONS

General Design Features

MULTI-JET WATER METERS

WARNING CAUTION. CAUTION Do not exceed 120 psig (8.3 bar) air-inlet pressure.

Corrosion Resistant and Ultra-Pure Rotameters for Accurate Measurement of Liquids and Gases

Positive Displacement Flowmeters GM007 series instruction manual

7430 Series Hastelloy / Monel / Stainless Steel Installation Instructions

DOR INSERTION PADDLE WHEEL FLOWMETER

200 Series Flow Meters

TBM Series 3-Way Ball Valve

L-Series: LIQUID LEVEL FLOAT SWITCH. Single-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

introduction < STANDARDS >

Installation and Operating Instructions For MANUAL MANIFOLD SDLA& SDLAHP SERIES

Dual/Triple Manifold Water Filtration Systems Instruction Manual

introduction VR Piston Check Valves Product Data Sheet

Compact Electric Actuated Ball Valves PVC Body, Teflon/EPDM Seals 1/2 to 1 inch Pipe

OVAL GEAR FLOWMETER ELECTRONIC MODEL 019 / ¾

L007 LIQUID LEVEL FLOAT SWITCH. Side-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

JET METER INSTRUCTIONS

Variable Area Flow Meters

CIRCLE SEAL CONTROLS

OVAL GEAR FLOWMETER ELECTRONIC MODEL 006/009 (¼ )

Quality Since 1980 SERVICE GUIDE. Eliminator Series HD, HDL, HDR, SD EDrive Actuators, Inc. #FB6070 Linear Actuators

Installation, Operation and Maintenance Manual

SAFETY MANUAL READ FIRST!

Ratio Feeder DB & DD Series Injectors

Dual Flow Manifold Systems Instruction Manual

Hydraulic Gear Puller Instruction Manual

PROMAG SR SERIES SEAL-LESS CENTRIFUGAL PUMPS

OFFICINE OROBICHE S.p.A. 1/7 INSTRUCTION MANUAL FOR FLOW SWITCHES PL SERIES

M-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components

Dual Port Manifold Water Filtration Systems Instruction Manual

Sediment strainer (Type Y)

Operating Instructions for Polysulfone Paddle Monitor. Model: PPS-..

Manifold Isolation Valves

MANUAL PALLET VALVE # Manifold Mount Outlet Port # /16-20 UNF SAE-4 Outlet Port # /4 NPT Outlet Port Max. Capacity: 5,000 PSI

Operating Instructions for Float Flow Meter / Monitor. Model: SWK

1/2" AIR DRIVEN DIAPHRAGM PUMP

L500 LIQUID LEVEL FLOAT SWITCH. Single or Multi-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

ABB Automation. Variable Area Dial Flow Indicator Series 10A2227. Series 10A2227 Variable Area Dial Flow Indicator

Positive Displacement Flowmeters GM020 series instruction manual

XP-115 Multi-Port Power Pack Operation and Maintenance Manual

CALEFFI. QuickSetter Balancing Valve with flow meter. Installation Tip

Operating Instructions for Float Flow Meter / Monitor. Model: SWK

Scale Feeder Manifold Water Filtration System Instruction Manual

Full Flow Drinking Water System Model: 3MFF100

Value Super Filter Max Installation Manual

EZ-View Flow Meters. General Design Features OPERATING PRINCIPLE

Gauge Adapter Instruction Manual

XP-AIR Multi-Port Power Pack Operation and Maintenance Manual

HARMSCO Hurricane Swing Bolt Water Filters Models: HUR 1X170FL, HUR 3X170FL HUR 5X170FL, & HUR 8X170FL

FPD1001 thru FPD1003, FPD1102 and FPD1103, FPD1201 thru FPD1203 (includes -R Option) Positive Displacement Flowmeters

OPERATION AND MAINTENANCE MANUAL

MINI-NBK ECONOMICAL LEVEL INDICATOR

Contents H-V034-E-12. Serial No. (page) (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

INSTALLATION & SERVICE INSTRUCTION MANUAL W.A. KATES FLOW CONTROLLERS FC VALVE MODELS E THRU M

Medi-Flow. Model M101 & M101D Medicator Instructions GETTING TECHNICAL ASSISTANCE

Air Operated 1:1 Oil Ratio Pump OP-11

introduction RV Series Sediment Strainers Product Data Sheet

L312 LIQUID LEVEL FLOAT SWITCH. Multi-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

APCO CSV-1600 SURGE CHECK VALVE

Rotary Cutter Drives Service Manual

Page 1 of 26 Oteco Inc. Houston, Texas

CHESTERTON FLOW GUARDIAN S50 AND SP50 SINGLE FLOWMETER INSTALLATION INSTRUCTIONS

SINGLE ACTION FLUID PUMP

EZ-View Flow Meters. With Flow-Alert TM Flow Switch REDUCE MAINTENANCE COSTS TEL

Flowmeter, Plastic 805 / 807 / 815 / / 825 / 832 / 835. Sectional drawing

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

4.2 WATER PUMP (GEAR CASE MOUNTED AND LATER) (GCM)


Installation Manual DIAPHRAGM WELL TANK

007 Tank Monitor. WARNING Never use with gasoline or highly flammable liquids.

Armstrong Double Duty 6 Steam Trap/Pump Combination Installation and Maintenance

DISCONTINUED. Installation. Aerada 900 Series Futura Faucet. With Accu-Zone (AZ) Infrared Control

Input Adjusting Ring Leak Repair Procedure for Meritor MT-14X Series Forward Differential Carriers

Transcription:

KOBOLD KSK FLOWMETER User Instructions USA 1801 Parkway View Drive Pittsburgh, PA 15205 PH 412-788-2830 Canada 9A Aviation Point Claire, QC H9R 4Z2 PH 514-428-8090 www.koboldusa.com KSK_manual_rev. 2/10

1 KSK KOBOLD KSK FLOWMETER User Instructions CAUTION: For safety reasons, please read the cautionary information located at the end of the manual, before attempting installation. 1.0 General The KOBOLD KSK flowmeter is a low volume flow measuring device, intended for applications in which the corrosion resistance of synthetic materials (plastic) is required. The KSK operates on the principle of the variable area flowmeter (float in a conical tube or rotameter ). The KSK may be factory-fitted with switches to allow control of external electronics. 2.0 Specifications Table 2.1; Technical Data Operating Principle: Display: Overall Series Flow Range: Maximum Operating Temperature: Maximum Operating Pressure: Float in a conical tube Direct reading, calibrated for H 2 O or Air From: 0.006 to 4.4 GPM Water, 0.06-62 SCFM Air 140 F w/ PVC Fittings 180 F PSU w/ Polypro, brass, or stainless steel fittings 250 F PVDF (180 F w/ switch) 145 PSI Table 2.2; Material Construction Body: Float: O Rings: Fittings: Polysulfone, Trogamid or PVDF (based on model number) PVDF EPDM PVC, PVDF, stainless steel or brass (based on model number)

2 KSK Diagram 2.1; Wiring Diagram of Transistor Switch Table 2.3 Switch Specifications Transistor Switch: Type: NPN, open collector, Bi-stable Operating voltage: 9 to 24 VDC Operating current: 100 ma max. Output signal: Float Above Contact:LED on (Pin 1-Pin E: closed) Float Below Contact:LED off (Pin 1-Pin E: open) Reed Switch: Type: Operating voltage: Operating current: SPST, N/O or N/C (depends on order code) 130 VAC max. 0.5A, 10 W / 10 VA Diagram 2.2 Wiring Diagram of Reed Switch

KSK 3 3.0 Installation Instructions CAUTION: For safety reasons, please read the cautionary information located at the end of the manual, before attempting installation. 3.1 - Mounting The KSK comes supplied with process fittings and union nuts. To install the instrument, simply: 1. Remove the fittings from your KSK by loosening the union nuts. 2. Place union nut over pipe to which you wish to connect. 3. a.) Glue connections: Per manufacturer's instructions, use a suitable PVC adhesive to glue fittings in place and let cure. b.) Threaded connections: Apply a suitable thread sealant to the male mating threads and hand tighten the insert fitting just enough to prevent leaks. 4. Fasten connectors to KSK with the union nuts, taking care not to overtighten the assembly. If necessary, only use a strap wrench on the nuts. DO NOT USE a pipe wrench, pliers, or any other sharp instrument on the fittings, as this may compromise the strength, and eventual safety of the instrument. NOTE: The KSK must be installed vertically (long axis), with the inlet at the bottom. There are no straight run requirements for the inlet/outlet piping. 4.0 Operation We recommend that, if possible, the medium be introduced to the instrument in gradually increasing amounts. This procedure serves two basic functions: 1. It prevents excessive oscillation of the float upon sudden introduction of media (particularlygases). 2. It prevents possible damage to the instrument caused by pressure surges (as described in the cautionary section). 4.1 - Reading the Flow Rate Flow rates measured by float type devices are typically read at the largest float diameter. In the case of the KSK, this is the top edge of the float.

4 KSK 4.2- Adjusting the Setpoint Switches All setpoint switches are adjusted in an identical fashion. To adjust a setpoint: 1. Loosen the holding screw found on the setpoint indicator body, near the V-groove. 2. Slide the indicator to the desired setpoint value. 3. Retighten the holding screw, taking care not to overtighten. 4.3 - Operating the Setpoint Switches The setpoint switches will output a signal to indicate change of flow status. There are two possible states for the switch to be in: One indicates that the float is located above the setpoint position, and the other that the float is below the setpoint position. Wiring diagrams for the setpoint switches are shown in Diagrams 2.1 and 2.2. 5.0 Maintenance The major enemy of float-type flowmeters is dirt and large debris We recommend that only clean or filtered media be passed through the device. If using a setpoint switch, it is particularly important to guard from contamination by ferritic (metal) materials due to the magnetic insert encapsulated within the float. To protect from the type of debris, we suggest the installation of a magnetic filter, such as a KOBOLD MFR, or equivalent. 6.0 Arrival of Damaged Equipment Your instrument was inspected prior to shipment and found to be defect-free. If damage is visible on the unit, we advise that you carefully inspect the packing in which it was delivered. If damage is visible, notify your local carrier at once, since the carrier is liable for a replacement under these circumstances. If your claim is refused, please contact KOBOLD Instruments for further advisement. 7.0 Need help with your KSK? Call one of our friendly engineers at 412-788-2830.

KSK 5 Caution PLEASE READ THE FOLLOWING GENERAL FLOW METER/ MONITOR WARNINGS BEFORE ATTEMPTING INSTALLATION OF YOUR NEW DEVICE. FAILURE TO HEED THE INFORMATION HEREIN MAY RESULT IN EQUIPMENT FAILURE AND POSSIBLE SUBSEQUENT PERSONAL INJURY.

6 KSK Inspect instrument for damage upon arrival. Cracked, fractured, bent or otherwise damaged instruments must not be put into use, since the device is weakened to an unknown extent. (The operations and installation guide will explain how to make a claim on damaged instruments.) Under NO circumstances must the maximum tolerances (temperature and pressure) be exceeded. The maximum tolerances of the device have been determined using water and air. If using other media, especially corrosive, it is critically important that the user determine chemical compatibility with our instruments. KOBOLD Instruments Inc. cannot accept responsibility for failure and consequences resulting from use of media other than water or air. Install the device in a fully supported position within your flow system. This avoids excessive stresses which may damage the instrument. In particular: a. Ensure that the plumbing leading to and from the instrument is fully supported and that the instrument does not perform the physical function of a joint. b. When calculating stress on the device caused by plumbing, the weight of the medium in the pipes must be considered as well. c. Misaligned runs of rigid piping can cause large stresses when connected to the instrument. Do not connect in such a fashion. During installation, avoid stresses on the instrument by following guidelines given below: a. When connecting fittings, hold the instrument fittings rigid with a strap wrench. Do not install by twisting the instrument into the pipe fittings. b. Do NOT install by holding the device housing to provide counter-torque to the pipe fitting. c. Use an appropriate amount of a suitable sealant on male threads of NPT fittings. This reduces the twisting stresses produced by tightening the fittings into each other. d. Do not use pliers or wrenches on the housing, as this may damage it. e. Do not overtighten, as this may fracture the fittings.

KSK 7 During operation, there are a number of situations to avoid: a. The sudden cessation of fluid flow causes what is typically referred to as "water hammer". Most people are familiar with this phenomenon from their home experience - it is the cause behind the loud clank of water pipes which occurs when faucets are turned off too suddenly. The cause behind this "water hammer" is quite easy to visualize. Water is fairly massive. The amount of water in long runs of pipe is quite substantial. When the faucets are turned off suddenly, especially from a full on condition, the water has considerable momentum and does not want to stop flowing. The situation is similar to stopping a car by running into a wall, rather than by applying brakes. Both are sudden rather than gradual. The damage to the wall can be substantial (not to mention the car). The "water hammer" causes surges in fluid pressure which could cause the measurement instrument's pressure limit to be exceeded, resulting in failure and possible personal injury. b. Fluid surges, as well as the water hammer, can be particularly damaging to empty flowmeters since there is no back pressure in the device. The damage is caused, once again, by momentary excess pressure. To avoid these surges, fluid lines should remain full (if possible) and water flow should be introduced to the device slowly. c. If the instrument is isolated with inlet and outlet valves, the flowmeter must be completely drained when said valves are both closed. Failure to do so could result in damage to the device caused by thermal expansion of fluid. d. Freezing of water in the instrument must be avoided since the resultant expansion will damage the flowmeter and make it unsafe for use.