NEW. Wall controls. SkyStar SkyStar ECM Cassette Fan Coil Units. Air Conditioning. Cert. n 0545

Similar documents
Carisma CRC. Range includes 9 air rates (from 105 to 1500 m 3 /h) It is the most comprehensive range, perfectly suited to meet

Cert. n 0545 Carisma CRC Fan Coil Unit The Ultra Quiet Fan Coil TECHNICAL GUIDE

Carisma The Ultra Quiet Fan Coil

NEW. Wall controls. YFCN Fan Coil Units. Technical Guide - for internal distribution only

Technical Catalogue. Cassette Fan Coils Climmy Comfort 3

Maestro. High Pressure Fan Coil Unit with Asynchronous Motor

CMTE. Tangential Fan Coil Series with Electronic Controlled Motor

42GW. Hydronic Cassette Fan Coil Units PRODUCT SELECTION DATA INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS EASY INSTALLATION

ERP 2015 Regulation (EU) Compliant with. No. 327/2011. Cert. n Heating. Meltemi Door Curtains

CENTRIFUGAL FAN COIL UNIT VCE

EURUS / EURUS-I. Conditioning your ambient, maximising your comfort.

CLOSE CONTROL UNITS WITH CHILLED WATER COIL

Product Catalogue ARMONIA Providing indoor climate comfort

Chiller Close Control Water terminals SYSCASSETTE. Water cassette units

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

Total cooling capacity kw Total heating capacity kw Features

KLIMA Active Chilled Beams

Air-Cooled Liquid Chiller with integrated hydraulic module

BRIZA 22 HYBRID HEATING & COOLING

Fan coil unit NBS 100/150

TECHNICAL MANUAL SOFFIO Ducted units

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h

something new in the air Technical Bulletin

Fan coil units MAJOR 2 CV/CH

The World Leading Air-conditioning Company

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial

Fan coil units. Why choose Daikin fan coil units? 540 Products overview 542. Options & accessories 560. Round flow cassette 544 FWC-BT/BF 544

42N. Room Fan Coils PRODUCT SELECTION DATA. MAINTENANCE INSTRUCTIONS Simpified installation & large options choice

technical catalogue tetris KW Chiller and heat pumps air/water

TECHNICAL MANUAL ESTRO BLDC ESTRO BLDC FAN COILS - BRUSHLESS TECHNOLOGY. 1.5 kw kw

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

DOUBLE SKIN MODULAR AIR HANDLING UNIT. Round Edge (ADM-AHU)

Water terminals From 360 to 1598 m 3 /h. From 1.3 to 9.6 kw. SysQuare. Chilled water cassettes. From 1.1 to 14.0 kw

Total comfort control

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM

42NL & 42NH. Hydronic Ducted Fan Coil Units PRODUCT SELECTION DATA. Modular Horizontal ducted unit. Extremely quiet operation. Low Energy Consumption

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

BASTONE (dual) fancoil Units

CHP

FCX TECHNICAL BOOKLET

GigaBox centrifugal fans Product specific information

Fan coils with Inverter Brushless motor (EC) Concealed installation

fåçìëíêá~ä=~áê=åççäéêë=qvo pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö

Resolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h

HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL

42NL & 42NH. Hydronic Ducted Fan Coil Units PRODUCT SELECTION DATA. Modular Horizontal ducted unit. Extremely quiet operation

D M S 760 C01 A A 1 1

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03

Chilled Water Vertical Fan Coils

Air Curtains for Revolving Doors

Fan Coil Units. Technical Data ECDEN FWL-DT/DF

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option

Midea Air Handling Unit

Prepared By : Checked By : Approved By : Page 1 out of 6

HIGH INDUCTION DIFFUSERS WITH VARIABLE GEOMETRY

CONFIGURABLE HIGH-EFFICIENCY HEAT RECOVERY UNITS CADB/T-HE PRO-REG Series

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

Multi directional heating. Air heaters Model NOZ

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2

LSE kw. Outdoor packaged unit. Air/water chillers and heat pumps LSE PLUS

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

TECHNICAL DOCUMENTATION WOLF AIR HEATERS LH-EC / LH. 30m 3 /h

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB

Commercial Blower Coil Air Handlers

fåçìëíêá~ä=~áê=åççäéêë=qelo pí~åç~êç=åççäéêë=ïáíü=`ì=íìäáåö

next dx next dx rcgroupairconditioning NEXT DX: Direct expansion close control air conditioners equipped with scroll compressors and Plug-fans.

^áêëçåâ=ìåáí=åççäéêë=qvoj^ pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö

Catalogue of Accessories

HIGH INDUCTION DIFFUSERS WITH VARIABLE GEOMETRY

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

DC INVERTER VRF SYSTEMS C-VRF

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

HYDROCIAT LW. Use. Range. Water-cooled chillers. Screw compressors CIAT shell and tubes direct expansion evaporator HPS (High Power System) equipment

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

BRIZA EC 12 HYBRID. World s slimmest fan coil HEATING AND COOLING

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Use. Installation. Key figures. Worth noting. linx industries chilled beams

ACOUSTIC CABINET FANS CVB / CVT Series

ED.X Kc DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS. COOLING CAPACITY FROM 6,7 TO 138 kw. ED.X 331 U Kc

MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

Highline 260i EC Waterside Fan Coil Unit

TD-ECOWATT AND DECOR-ECOWATT Series

BAC / BHC Product Specifications

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

CNVA TECHNICAL DOCUMENTATION. Active floor convector. Contents

CALEFFI. Pre-assembled distribution manifolds for. heating and air-conditioning systems. 663 series 01065/18 GB. replaces dp 01065/06 GB.

FRESH BREEZE FAN-FILTER UNIT TECHNICAL DATA

Accessories. Series REC

CornerAir. CornerAir. Active chilled beam

YFCN Fan Coil Unit centrifugal fan 2 & 4 pipe system A complete range from 1.0 kw to 7.6 kw

Fan coil units. HFCE, HFXE, VFCE, VFXE series Sizes 03 to to 3400 m3/h UNT-PRC007-E4

HTC. Air cooled Condensers. Capacities kw. Ripple Fin tubing Floating coil block suspension

Transcription:

NEW Wall controls Cert. n 04 www.eurovent-certification.com Air Conditioning ECM Cassette Fan Coil Units

CONTENTS Introduction Page 3 Main components Page 4 EUROVENT Certifications Page s Page 6 side pressure drop Page 9 Working conditions Page 9 Dimensions and weights Page 0 Air throw Page 2 Fresh air supply Page 3 Air distribution Page 3 Accessories Page 4 CRYSTALL electrostatic filter Page 20 Wall electronic controls Page 24 Controls for S MB versions Page 2 Electric heater S E Page 26 ECM Introduction Page 28 Main components Page 29 EUROVENT Certifications Page 30 s Page 3 side pressure drop Page 33 Working conditions Page 33 Dimensions and weights Page 34 Air throw Page 36 Accessories Page 37 S ECM configuration Page 39 Wall electronic controls Page 40 Controls for S ECM MB versions Page 4 Electric heater S ECM E Page 42 MD-600 Version MCT Introduction Page 43 Dimensions and weights Page 44 Assembly diagram Page 4 Components of the casing Page 46 Valve kit Page 46 Sabiana take part to the Eurovent program of fan coil performance certification. The official figures are published in the web site www.eurovent-certification.cm. The tested performances are: Cooling total emission at the following conditions: - temperature +7 C E.W.T. +2 C L.W.T. - Entering air temperature +27 C dry bulb +9 C wet bulb Heating emission (2 pipe units) at the following conditions: - Entering water temperature +0 C - Entering air temperature +20 C - rate as for the cooling conditions Cooling sensible emission at the following conditions: - temperature +7 C E.W.T. +2 C L.W.T. - Entering air temperature +27 C dry bulb +9 C wet bulb Heating emission (4 pipe units) at the following conditions: - temperature +70 C E.W.T. +60 C L.W.T. - Entering air temperature +20 C Fan absorption pressure drop Sound power

Introduction Innovating and beautiful design, seven different sizes, high control flexibility, easy maintenance: the new chilled water cassette is the result of an extended technical and design development aimed at achieving the highest level in terms of performance, silent operation and control possibilities. The air diffuser has an highly attractive aesthetical appearance, very innovative, and is also able to offer the best air distribution performance thanks to long computer studies and laboratory tests. The standard colour is RAL 9003, other colours available on request. The 4 smaller sizes are designed to fit into 600x600 mm false ceiling standard modules. The 3 bigger sizes have a dimension of 800x800 mm which allows the best outcome in terms of quietness and of price/performance ratio for these high capacity models. Every unit can be supplied with battery (2 pipe system) and a possible electric heater or with 2 batteries (4 pipe system). Each model can have fresh air intake and a remote air diffuser can be connected to the unit. The condensate pump is integral with the unit, is very quiet and has a maximum head of 60 mm. In addition to temperature and speed standard controls, automatic speed selection is also available. More than one unit can be connected to a single control, and the unit control panel can be installed in a remote position that facilitates the maintenance operation. All the units can be supplied in MB version. This version allows a wide range of controls, including the infra-red remote control, which can manage one single unit or several units by using the Modbus RTU - RS 48 communication protocol. The units can be connected to the most common automatic building management systems. It is also possible to use a completely wireless electronic control system based on radio communication called Free Sabiana, with great advantages in terms of installation flexibility and maximum precision in measuring room temperature. Finally, each unit can be equipped with a low energy consumption electric motor that is controlled by an inverter card that makes possible continuous air variations. 3

Main components INTAE GRID AND DISTRIBUTION OF THE AIR Intake grids, frame and adjustable air distribution louvers on each side, made from ABS. HTA version : white ABS, RAL 9003 HTB version : with intake grid, frame and louvers, choice of one colour only HTC version : with intake grid and louvers, choice of one colour, plus white ABS frame RAL 9003 HTD version : with louvers, choice of one colour, while the grid and frame are made from ABS, RAL 9003 MD-600 version : metal diffuser painted in RAL 9003 white colour with 600x600 dimension to perfectly fit into the false ceiling standard modules without overlapping parts (800x800 model is not available). CASING Is made from galvanized steel with internal thermal insulation with polyolefin (PO) foam (class M) and external anti-condensate lining. CONTROL PANEL Made of an external box with the control electronic board with an easily accessible terminal board. FAN ASSEMBLY The fan assembly, which is mounted on anti-vibrating supports, is extremely silent. The radial fan has been designed to optimise performance, using wing profile blades with a shape that reduces turbulence, increasing efficiency and reducing noise. The single air inlet radial fan is connected to a 6 speed electric motor with single phase 230V/0Hz supply, class B insulation and integrated lixon thermal contact for motor protection. The units are supplied with 3 standard speeds connected and it is possible to change them on site if necessary. COIL Made of copper tubes with bonded aluminium fins for maximum transfer contact. The coil has, 2 or 3 rows for 2 pipe models and 2+ rows for 4 pipe models (the heating row is on the inside part of the coil). For 4 pipe systems two versions are available: S 04, S 4, S 24, S 34, S 44, S 4, S 64 supply an higher heating emission; S 26, S 36, S 6, S 66 supply an higher cooling emission. The heat exchanger is not suitable for use in corrosive atmosphere or in environments where aluminium may be subject to corrosion. CONDENSATE COLLECTION TRAY density ABS polystyrene foam condensate tray, shaped in order to optimize the air diffusion, fire retardant rating B to DIN 402. AIR FILTER Synthetic washable filter, easily removable. CONDENSATE PUMP Float switch centrifugal pump with 60 mm of maximum head, integral to the unit and wired to the control panel on the outside of the casing. VALVE SET Two or three way valves for ON/OFF operation, with pipe mounting kit and thermostatic actuator. 4

EUROVENT Certific. Technical features www.eurovent-certification.com 2 pipe units. The following standard rating conditions are used: COOLING Entering air temperature: + 27 C d.b., + 9 C w.b. HEATING Entering air temperature: + 20 C temperature: + 7/2 C temperature: + 0 C water rate as for the cooling conditions MODEL Speed Air m 3 /h Cooling total emission (E) kw Cooling sensible emission (E) kw Heating (E) kw l/h P Cooling (E) kpa P Heating (E) kpa Sound power Lw (E) db(a) Sound pressure Lp ( * ) db(a) Fan (E) content Dimensions W A l mm S 02 2 3 30,27,0,62 29 4, 4,0 33 24 2 0, 420,63,32 2,2 280 7,0 6,0 40 3 32 0, 0,8 60,98,64 2,64 340 0,0 9,0 49 40 7 0,27 2 3 2 3 2 3 2 3 2 3 2 3 420 2,34,7 20 2,68 2,04 320 2,2,7 00 3,34 2,39 4,33 3,8 430 2,94 2,08 60 3,88 2,8 880,02 3,74 630 4,2 3,03 820 4,9 3,8 40 6,6 4,9,3 3,46 970 6,78 4,48 00 9, 6,48,3 3,7 280 8,4 6,09 2,90 3,3 2,6 3,93,23 3,43 4,63 6,7,2 6,03 7,77,6 7,34 0,7 6,3 0,30 402 46 387 74 74 06 667 863 724 84 060 93 66 636 93 43 7,6 6,3 40 3 32 0, 9,7 8,2 4 36 44 0,20 4,6 3, 33 24 2 0, 9,4 7,3 4 36 44 0,20,,4 3 44 68 0,32 7, 6,7 4 32 32 0, 2,4,2 49 40 7 0,27 9,7 7,7 9 0 90 0,4 0,9 6,7 33 24 33 0, 4,3 9,9 40 3 48 0,23 2,6, 48 39 77 0,36 9,4 7,9 34 2 42 0,8 4,7 2,4 40 3 63 0,28 26,9 23,0 3 44 20 0,3 9,4 7,9 34 2 42 0,8 2,8 8,6 48 39 9 0,42 30,84,3 2,22 36 4,9 4, 33 24 2 0, S 2 S 22 S 32 S 42 S 2 S 62,4 2, 2, 3,0 4,0 4,0 7 x 7 x 27 820 x 820 x 303 820,0 8,2 4,00 909 3,6 30,6 8 49 70 0,74 4 pipe units. The following standard rating conditions are used: COOLING Entering air temperature: + 27 C d.b., + 9 C w.b. HEATING Entering air temperature: + 20 C temperature: + 7/2 C temperature: + 70/60 C MODEL S 04 S 4 S 24 S 26 S 34 S 36 Speed Air m 3 /h Cooling total emission (E) kw Cooling sensible emission (E) kw l/h P Cooling (E) kpa Heating (E) kw l/h P Heating (E) kpa Sound power Lw (E) db(a) Sound pressure Lp ( * ) db(a) Fan (E) Cooling water content Heating water content Dimensions W A l l mm 2 3 2 3 2 3 2 3 2 3 2 3 420,96, 337 0,0 2,4 29 0, 40 3 32 0, 60 2,33,90 40 3, 3,03 26 4, 49 40 7 0,27 30,8,34 38 4,6 2,43 209,7 33 24 2 0, 420 2,36,7 406 6,9 3,02 260 8, 40 3 32 0, 20 2,70,98 464 8,8 3,46 298 0,8 4 36 44 0,20 320,8,34 38 4,6 2,43 209,7 33 24 2 0, 00 2,6,98 46 8,8 3,46 298 0,8 4 36 44 0,20 3,34 2,6 74 3,4 4,40 378 6,6 3 44 68 0,32 320 2,09,49 39 4,0,98 70 3,6 33 24 2 0, 00 3,06 2,24 26 7,0 2,7 233 6,0 4 36 44 0,20 3,93 2,9 676 0, 3,3 288 9,0 3 44 68 0,32 430 2,36,7 406 7,2 3,0 267 8,8 4 32 32 0, 60 3,02 2,29 9,2 3,97 34 3,8 49 40 7 0,27 880 3,8 2,97 6 7,0 4,9 426 20, 9 0 90 0,4 430 2,72,97 468 6,0 2,46 22,0 4 32 32 0, 60 3,3 2,62 607 9,0 3,06 263 7,8 49 40 7 0,27 30,, 260 6,0,96 69 6, 33 24 2 0,,0 0,6 0,23 3,0,4,4 0,7 0,28 3,0,4,4 0,7 0,28 3,6, 820 x 820 x 303 7 x 7 x 27 MODEL S 44 S 4 S 6 S 64 S 66 Speed 2 3 2 3 2 3 2 3 2 3 Air m 3 /h 630 820 40 970 00 970 00 280 820 280 Cooling total emission (E) Cooling sensible emission (E) kw kw 4,4 2,96,03 3,6 6,34 4,69 4,2 3,2,66 4, 7,7,83 4,99 3,3 6,33 4, 8,77 6,49 4,2 3,2 6,93,8 8,89 6,84 4,99 3,3 7,84,73 l/h 72 86 090 777 974 326 88 089 08 777 92 29 88 348 P Cooling (E) kpa 8,8 2, 8,9 0,3,4 26,9 9,0 4,0 2,0 0,3 22, 34,7 9,0 20,0 Heating (E) kw,9 7,9 9,0 6,4 8,0,00,23 6,42 8,6 6,4 9,98 2,70,23 7,74 P Heating (E) Sound power Lw (E) Sound pressure Lp ( * ) l/h kpa db(a) 08 9,8 33 24 68 4,0 40 3 783 2,4 48 39, 34 2 697 7,4 40 3 946 29,9 3 44 40 6, 34 2 2 9,2 40 3 736,3 3 44, 34 2 88 2,3 48 39 092 38,8 8 49 40 6, 34 2 666 3,0 48 39 Fan (E) W 33 48 77 42 63 20 42 63 20 42 9 70 42 9 A 0, 0,36 0,8 0,3 0,8 0,3 0,8 0,74 0,8 Cooling water content Heating water content Dimensions l l mm Condensate pump absorption: 0 W (E) = Eurovent certified performance. (*) = The sound pressure levels are 9 db(a) lower than the sound power levels and apply to the reverberant field of a 00 m 3 room and a reverberation time of 0. sec.,7 0, 0,42 3,0,4,4 0,7 0,42 3,6, 820 0,20 7,68 74 32,0 9,80 843 9, 8 49 70 0,74,7 0, 880 4,3 3,46 779 4,0 3,79 326,0 9 0 90 0,4

Cooling emission of battery units (2 pipe installation) Entering air temperature: +27 C d.b. +9 C w.b. Model S 02 S 2 S 22 S 32 S 42 S 2 S 62 Speed Air m 3 /h 60 420 30 20 420 30 00 320 880 60 430 40 820 630 00 970 820 280 EWT - LWT 0 C EWT 7 - LWT 2 C EWT 9 - LWT 4 C EWT 2 - LWT 7 C Total Sensible Total Sensible Total Sensible Total emission emission emission emission emission emission emission Sensible emission l/h kw kw l/h kw kw l/h kw kw l/h kw kw 42 346 269 4 482 47 926 7 08 049 83 633 264 003 88 943 374 070 2277 722 070 2,4 2,0,7 3,22 2,80 2,42,38 4, 2,9 6,0 4,8 3,68 7,3,83 4,99,30 7,99 6,22 3,24 0,0 6,22,83,48,4 2,22,9,64 3,64 2,77,94 4,7 3,26 2,44,00 3,92 3,32 7,9,27 4,06 9,0 6,68 4,06 340 280 29 462 403 37 74 7 387 863 667 06 060 84 722 63 66 93 909 44 93,98,63,27 2,68 2,34,84 4,33 3,34 2,2,02 3,88 2,94 6,6 4,9 4,2 9, 6,78,3,0 8,4,3,64,32,0 2,04,7,3 3,8 2,39,7 3,74 2,8 2,08 4,9 3,8 3,03 6,48 4,48 3,46 8,2 6,09 3,7 24 20 6 362 37 276 67 483 349 694 9 430 840 674 80 30 939 740 62 740,47,22 0,96 2,0,84,6 3,9 2,8 2,03 4,03 3,2 2,0 4,88 3,92 3,37 7,7,46 4,30 8,78 6,7 4,30,4,6 0,89,7,0,29 2,87 2,8,3 3,29 2,7,92 3,9 3,09 2,62,99 4, 3,20 7,,27 3,20 99 60 23 22 220 88 420 39 22 479 376 283 73 43 384 880 62 434 044 77 434,6 0,93 0,7,47,28,09 2,44,86,3 2,79 2,9,6 3,33 2,63 2,23,2 3,6 2,2 6,07 4, 2,2,6 0,93 0,7,47,28,09 2,44,86,3 2,79 2,9,6 3,33 2,63 2,23,2 3,6 2,2 6,07 4, 2,2 Heating emission of battery units (2 pipe installation) Entering air temperature: +20 C Model S 02 S 2 S 22 S 32 S 42 S 2 S 62 Speed Air 60 420 30 20 420 30 00 320 880 60 430 40 820 630 00 970 820 280 EWT 4 - LWT 40 C EWT 0 - LWT 40 C EWT 60 - LWT 0 C EWT 70 - LWT 60 C EWT 80 - LWT 70 C m 3 /h l/h kw l/h kw l/h kw l/h kw l/h kw 386 30 237 482 47 36 787 93 42 903 702 20 8 86 734 683 46 876 20 47 876 2,24,80,38 2,80 2,42 2,07 4,7 3,4 2,39,2 4,08 3,02 6,0,03 4,27 9,78 6,67,09,72 8,,09 203 64 26 266 232 98 440 334 23 04 394 294 624 486 4 9 6 0 32 834 0 2,37,9,46 3,0 2,69 2,3,2 3,89 2,73,86 4,8 3,42 7,26,6 4,82,06 7,62,87 3,7 9,70,87 298 239 83 377 327 279 69 467 326 709 2 40 878 68 78 327 906 694 86 6 694 3,46 2,78 2,3 4,39 3,80 3,2 7,9,43 3,79 8,2 6,42 4,77 0,2 7,92 6,72,43 0,4 8,07 8,4 3,0 8,07 393 3 240 488 422 360 79 98 4 94 709 24 30 874 74 699 882 2037 484 882 4,6 3,66 2,80,68 4,9 4,9 9,2 6,96 4,83 0,63 8,2 6,0 3,4 0,6 8,6 9,76 3,43 0,2 23,68 7,26 0,2 488 39 298 99 3 44 972 730 0 8 866 639 383 067 903 207 403 068 2486 807 068,67 4, 3,47 6,97,96,2,30 8,48,87 3,00 0,07 7,43 6,08 2,4 0,0 24,08 6,32 2,42 28,9 2,0 2,42 correction factors for different working conditions. Multiply the factors by the emission figures in the 7-2 C table above. Total emission Sensible emission ( C) Air ( C) 2-8 26-8. 28-20 ( C) Air ( C) 2-8 26-8. 28-20 7/2 C 0/ C 4/8 C 0,82 0,6 0,3 0,89 0,63 0,4, 0,82 0,2 7/2 C 0/ C 4/8 C 0,9 0,72 0, 0,94 0,78 0,8,06 0,9 0,72 Note: the correction factors are indicative, as they are average values. 6

of 4 pipe units with standard cooling battery Cooling emission of 2 battery units (4 pipe installation) Entering air temperature: +27 C d.b. +9 C w.b. Model S 04 S 4 S 24 S 34 S 44 S 4 S 64 Speed Air m 3 /h 60 420 30 20 420 30 00 320 880 60 430 40 820 630 00 970 820 280 EWT - LWT 0 C EWT 7 - LWT 2 C EWT 9 - LWT 4 C EWT 2 - LWT 7 C Total Sensible Total Sensible Total Sensible Total emission emission emission emission emission emission emission Sensible emission l/h kw kw l/h kw kw l/h kw kw l/h kw kw 490 40 34 69 46 398 78 69 398 79 632 0 299 027 842 88 8 920 836 423 920 2,8 2,38,82 3,3 2,7 2,3 4,8 3,3 2,3 4,60 3,67 2,97 7,,97 4,89 9,23 6,73,3 0,67 8,27,3 2,2,73,29 2,26,83, 2,9 2,26, 3,23 2,3 2,0,2 4,00 3,24 6,3 4,3 3,6 7,43,64 3,6 40 337 260 46 40 38 74 4 38 66 20 40 090 866 73 327 974 778 29 9 778 2,33,96, 2,70 2,36,8 3,34 2,6,8 3,8 3,02 2,36 6,34,03 4,4 7,7,66 4,2 8,89 6,93 4,2,90,,,98,70,34 2,6,98,34 2,97 2,29,7 4,69 3,6 2,96,83 4, 3,2 6,84,8 3,2 307 260 20 374 309 267 467 374 267 2 43 337 864 69 72 046 77 623 99 942 623,78,,7 2,8,80, 2,72 2,8, 2,98 2,40,96,02 4,02 3,33 6,08 4,0 3,62 6,97,48 3,62,69,37,02,79,44,22 2,30,79,22 2,6 2,00,9 4,04 3, 2,6,02 3,7 2,8,98 4,46 2,8 239 96 48 260 20 77 330 260 77 366 288 23 86 462 374 7,26 24 4 849 646 4,39,4 0,86,,22,03,92,,03 2,3,67,3 3,4 2,68 2,7 4,22 3,0 2,39 4,94 3,7 2,39,39,4 0,86,,22,03,92,,03 2,3,67,3 3,4 2,68 2,7 4,22 3,0 2,39 4,94 3,7 2,39 Heating emission of 2 battery units (4 pipe installation) Entering air temperature: +20 C Model S 04 S 4 S 24 S 34 S 44 S 4 S 64 Speed Air EWT 4 - LWT 40 C EWT 0 - LWT 40 C EWT 60 - LWT 0 C EWT 70 - LWT 60 C EWT 80 - LWT 70 C m 3 /h l/h kw l/h kw l/h kw l/h kw l/h kw 60 420 30 20 420 30 00 320 880 60 430 40 820 630 00 970 820 280 26 2 66 283 247 96 3 277 96 402 37 247 77 609 0 929 686 47 074 84 47,49,2 0,96,6,44,4 2,04,6,4 2,34,84,44 4,48 3,4 2,9,40 3,99 3,8 6,24 4,9 3,8 34 3 87 49 30 03 84 46 03 2 66 30 40 324 267 493 36 29 69 449 29,6,3,0,73,,20 2,4,69,20 2,4,94, 4,76 3,77 3,,73 4,2 3,39 6,6,22 3,39 97 66 28 28 9 270 24 30 244 9 96 47 388 78 3 423 829 63 423 2,29,93,49 2,4 2,22,76 3,4 2,48,76 3,60 2,84 2,22 6,93,48 4, 8,34 6,7 4,92 9,64 7,60 4,92 26 29 69 298 260 209 378 298 209 426 34 267 783 68 08 946 697 092 88 3,03 2,4,96 3,46 3,02 2,43 4,40 3,46 2,43 4,9 3,97 3,0 9,0 7,9,9,00 8,0 6,4 2,70 9,98 6,4 32 272 20 38 32 247 444 30 247 0 40 32 970 766 629 70 864 686 33 064 686 3,78 3,7 2,44 4,7 3,63 2,87,7 4,07 2,87,93 4,67 3,63,28 8,90 7,3 3,60 0,04 7,98,74 2,37 7,98 correction factors for different working conditions. Multiply the factors by the emission figures in the 7-2 C table above. Total emission Sensible emission ( C) Air ( C) 2-8 26-8. 28-20 ( C) Air ( C) 2-8 26-8. 28-20 7/2 C 0/ C 4/8 C 0,82 0,6 0,3 0,89 0,63 0,4, 0,82 0,2 7/2 C 0/ C 4/8 C 0,9 0,72 0, 0,94 0,78 0,8,06 0,9 0,72 Note: the correction factors are indicative, as they are average values. 7

of 4 pipe units with enhanced cooling battery Cooling emission of 2 battery units (4 pipe installation) Entering air temperature: +27 C d.b. +9 C w.b. Model S 26 S 36 S 6 S 66 Speed Air m 3 /h 00 320 880 60 430 00 970 820 280 EWT - LWT 0 C EWT 7 - LWT 2 C EWT 9 - LWT 4 C EWT 2 - LWT 7 C Total Sensible emission emission Total Sensible emission emission Total Sensible emission emission Total Sensible emission emission l/h kw kw l/h kw kw l/h kw kw l/h kw kw 82 629 42 940 729 7 804 29 02 20 607 02 4,72 3,66 2,47,46 4,24 3,24 0,49 7,0,89 2,24 9,34,89 3,29 2,,66 3,86 2,93 2,2 7,2,08 3,94 8,7 6,4 3,94 676 26 39 779 607 468 08 089 88 74 348 88 3,93 3,06 2,09 4,3 3,3 2,72 8,77 6,33 4,99 0,20 7,84 4,99 2,9 2,24,49 3,46 2,62,97 6,49 4, 3,3 7,68,73 3,3 28 4 287 606 477 370 89 867 689 37 066 689 3,07 2,4,67 3,2 2,77 2, 6,9,04 4,00 7,99 6,20 4,00 2,60,97,3 3,0 2,3,73,72 4,00 3,0 6,77,0 3,0 378 288 92 442 337 26 836 87 49 987 739 49 2,20,67,2 2,7,96,49 4,86 3,4 2,67,74 4,30 2,67 2,20,67,2 2,7,96,49 4,86 3,4 2,67,74 4,30 2,67 Heating emission of 2 battery units (4 pipe installation) Entering air temperature: +20 C Model S 26 S 36 S 6 S 66 Speed Air 00 320 880 60 430 00 970 820 280 EWT 4 - LWT 40 C EWT 0 - LWT 40 C EWT 60 - LWT 0 C EWT 70 - LWT 60 C EWT 80 - LWT 70 C m 3 /h l/h kw l/h kw l/h kw l/h kw l/h kw 279 226 6 3 2 20 720 4 44 824 6 44,62,32 0,96,83,48,9 4,8 3,4 2,6 4,79 3,79 2,6 39 3 83 6 27 03 493 36 29 69 449 29,6,32 0,97,82,48,20 4,33 3,27 2,67 6,6,22 3,39 23 73 27 24 9 7 4 46 340 633 0 340 2,48 2,0,47 2,80 2,27,83 6,44 4,84 3,9 7,36,83 3,9 288 233 70 326 263 22 736 2 40 843 666 40 3,3 2,7,98 3,79 3,06 2,46 8,6 6,42,23 9,80 7,74,23 363 294 24 4 332 266 99 689 6 03 83 6 4,22 3,42 2,49 4,78 3,86 3,0 0,69 8,0 6,2 2,24 9,66 6,2 correction factors for different working conditions. Multiply the factors by the emission figures in the 7-2 C table above. Total emission Sensible emission ( C) Air ( C) 2-8 26-8. 28-20 ( C) Air ( C) 2-8 26-8. 28-20 7/2 C 0/ C 4/8 C 0,82 0,6 0,3 0,89 0,63 0,4, 0,82 0,2 7/2 C 0/ C 4/8 C 0,9 0,72 0, 0,94 0,78 0,8,06 0,9 0,72 Note: the correction factors are indicative, as they are average values. 8

side pressure drop 2 pipe installation Pressure drop for mean water temperature of 0 C, for different temperatures multiply the pressure drop figure by the correction factors in the table. C 20 30 40 0 60 70 80 0,94 0,90 0,86 0,82 0,78 0,74 0,70 (l/h) 4 pipe installation Pressure drop for cooling battery Pressure drop for heating battery Pressure drop (kpa) Pressure drop (kpa) Pressure drop (kpa) (l/h) Pressure drop for mean water temperature of 0 C, for different temperatures multiply the pressure drop figure by the correction factors in the table. (l/h) Pressure drop for mean water temperature of 6 C, for different temperatures multiply the pressure drop figure by the correction factors in the table. C 20 30 40 0 60 70 80 C 40 0 60 70 80 0,94 0,90 0,86 0,82 0,78 0,74 0,70,4,08,02 0,96 0,90 Working conditions MAX. working pressure 8 bars Air Suitable relative humidity - 7% Supply Single phase 230V 0Hz Installation MAX. height: See table on page 2 MIN. entering water temperature: + C MAX. entering water temperature: + 80 C MIN. entering air temperature: 6 C MAX. entering air temperature: 40 C 9

Dimensions and weights S 02-04 / S 2-4 / S 22-24-26 / S 32-34-36 (Version 600 x 600) 2 pipe units - 3. Flow, heating/cooling /2-4. Return, heating/cooling /2 4 pipe units -. Flow, heating /2-2. Return, heating /2-3. Flow, cooling /2-4. Return, cooling /2 MD-600 / MD-800 METAL DIFFUSER (RS receiver, Code 9066338, for metal diffuser for MB units) Size MD-600 MD-800 A B C 99 880 74 84 34, 4, Code 9079420 907947 Model S 02-2 S 04-4 S 22-24 - 26 S 32-34 - 36 UNIT Weights Weights packed unit unpacked unit kg kg 28 22 30 24 DIFFUSER Weights Weights packed unit unpacked unit kg kg 6 3 Packed unit Dimensions A B C D mm 790 30 70 0 0

Dimensions and weights S 42-44 / S 2-4-6 / S 62-64-66 (Version 800 x 800) 2 pipe units - 3. Flow, heating/cooling 3/4-4. Return, heating/cooling 3/4 4 pipe units -. Flow, heating /2-2. Return, heating /2-3. Flow, cooling 3/4-4. Return, cooling 3/4 PACED UNIT UNIT DIFFUSER Model S 42 S 44 S 2-4 - 6 S 62-64 - 66 UNIT Weights Weights packed unit unpacked unit kg kg 44 36 47 39 DIFFUSER Weights Weights packed unit unpacked unit kg kg 0 6 Packed unit Dimensions A B C D mm 00 400 000 200

Air throw The air throw indicated in the tables must only be considered the maximum value, as it may change significantly in relation to the dimensions of the room in which the appliance is installed and the positioning of the furniture in the room. The useful throw L refers to the distance between the unit and the point where the air speed is 0.2 m/sec; if the louver has a gradient of 30 (recommended in cooling mode), the so-called Coanda effect will occur, illustrated in the first figure, while at a gradient of 4 (recommended in heating mode), there will be a downwards throw, as illustrated in the second figure. With adjustable air diffusion louvers at 30 Model S 02-04-2-4 S 22-24-26 S 32-34-36 S 42-44 S 2-4-6 S 62-64-66 Speed Air throw L m 2 3 2 3 2 3 2 3 2 3 2 3 3,0 3, 3,8 3,0 3,8 4, 3, 4,2,0 3,2 3,7 4,3 3,4 4,0,0 3,4 4,6, With adjustable air diffusion louvers at 4 Model S 02-04-2-4 S 22-24-26 S 32-34-36 S 42-44 S 2-4-6 S 62-64-66 Speed Air throw L m Height H m Distance B m 2 3 2 3 2 3 2 3 2 3 2 3 3,3 2,2 2, 3,9 2,6 2,9 4,2 2,8 3, 3,3 2,2 2, 4,2 2,8 3, 4,8 3,2 3,6 3,9 2,6 2,9 4, 3,0 3,4,2 3,4 3,9 3, 2,2 2,7 4, 2,6 3,2 4,8 3,0 3,8 3,8 2,4 3,0 4,6 2,8 3,6,4 3,4 4,2 3,8 2,4 3,0, 3, 4,0,8 3,6 4,6 NOTE: On heating it must be payed attention to rooms where the floor temperature is particularly low (for example less than C). In this situation the floor can cool the lower layer of air to a level that stop the uniform diffusion of the hot air coming from the unit, decreasing the throw figures shown in the table. 2

Fresh air supply - Fresh air connection The cassette is fitted with inlets for fresh air to be mixed with return air inside the unit (Fig. 3). FRESH AIR INLET The fresh air is limited to 20% of the total fan coil air at medium speed and 00 m 3 /h for each treated air inlet. The units feature fresh air inlets on three corners (no inlets on the fourth corner because of the condensate pump inside the unit). AIR INTAE Fresh air connection The fresh air inlets are designed for the insertion of standard 0 x mm rectangular ducts. The air duct is connected quickly and easily. After removing the blank and the insulation inside the unit, the mounting plate is rolled back and the air duct with its V-shaped section must be pushed into the unit (see Figures below). The duct is then fixed to the mounting plate. Note: the fresh air must be filtered. 2 3 4 MAIN AIR INLET Accessory Fresh air connection - Identification CAP - Code 607800 (see page 4) AIR INTAE Air distribution - Air distribution connection Two air outlets are provided on the side of the unit for connection to separate supply air outlets. AIR OUTLET They can be used to supply air from the fan coil unit to distant areas of a room or even to a different room. The total air does not change. The air at high speed depending on the air duct pressure drop is shown in the tables below. Note: all air ducts must be insulated in order to avoid condensation. Pressure drop (Pa) Spigot for air distribution AIR INTAE No. used outlets = No. used outlets = 2 Air (m 3 /h) Air (m 3 /h) Pressure drop (Pa) Pressure drop (Pa) Pressure drop (Pa) Air (m 3 /h) Air (m 3 /h) 3

Accessories Fresh air connection See page 3. Identification Code CAP 607800 Air distribution connection See page 3. Identification Code CDA 600 9079232 CDA 800 9079233 The diameter of the fitting is 0 mm for S 0 - - 2-3 and 80 mm for S 4 - - 6. Fresh air kit This is used to introduce fresh air into the environment directly through the diffuser. The kit includes a separator to be fitted inside the cassette, and a circular fitting for connection to the flexible system ducting. The of air is sent directly to just one of the outlet louvers, without passing through the coil. The air of fresh air introduced Model Identification S 0--2-3 PRT 600 S 4--6 PRT 800 into the environment depend on the inlet static pressure. 9079230 907923 Code Correlation between -rate / static pressure S 0--2-3 S 4--6 m 3 /h Pa m 3 /h Pa 80 20 60 200 240 3 8 2 36 60 200 300 400 00 3 8 2 36 The diameter of the fitting is 0 mm for S 0 - - 2-3 and 80 mm for S 4 - - 6. Units with remote electric board On request the Skystar cassettes are available with electric control panel reachable from below and with the electric board that can be placed in a remote position. In this case the units are supplied with an electronic connecting control panel, fitted to the bottom side on the 4 smallest sizes and to the lateral side on the 3 biggest sizes. The electronic control panel is connected to the fan motor, to the condensate pump and to the condensate level control. A 6 m wire is also supplied with integral plug-in connections to connect the unit with the remote electric board that can be installed in a suitable and comfortable position, where the power and system connections can be made easily. This feature is not available for units with electric heater or infrared remote control. 4

Accessories ON-OFF valves with thermoelectric actuator 3 ways 2 ways Valve with Micrometric Lockshield Valve Valve with Simplified it 3 ways 2 ways Technical data: Rated pressure: 6 bar Max. ambient temperature: 0 C Max. water temperature: 0 C Power: 230 V - 0/60 Hz Rating: 3 VA Protection: IP 43 Travel time: approx. 3 min. Max. glycol content of water: 0% Valves pressure drop Valves characteristics Battery type Main Auxiliary Model 02-2-22-32 04-4-24-26-34-36 42-2-62 44-4-6-64-66 04-4-24-26-34-36 44-4-6-64-66 vs m 3 /h 2,8,2 2,8 2 way valves 3 way valves pmax kpa * Valve ** connection vs m 3 /h pmax kpa * * maximum pressure difference for valve to close ** external thread, flat seal Note: 3 way valves with simplified kit and connection have conical seal. 0 60 0 3/4" " 3/4" 2, 4, 2, 0 0 0 Valve ** connection 3/4" " 3/4" p - kpa Valve set, 2 or 3 ways, ON-OFF, with thermoelectric actuator. The set includes connection pipes. Note: The main battery lockshield valve connection is /2 female (vs 2) for S0 - S - S2 - S3 sizes and 3/4 female (vs 3,) for S4 - S - S6 sizes, the auxiliary battery valve connection is /2 female (vs 2). (l/h) Note: The maximum pressure drop accross the fully open valve should not exceed 2 kpa for cooling operation and kpa for heating operation.

Accessories Balancing valves independent from the system pressure The balancing valve and a combined 2 way valve allow the regulation of the water value autonomously, regardless of the system pressure, and the control of the by using an ON/OFF electro-thermal actuator. The balancing valve allows you to balance the hydraulic system by supplying the required water, for each fan- coil, and to maintain it even under partial load conditions. A graduated ring nut placed under the valve allows you to set the rate value and also allows direct reading of the set value. Valve operation logic p is the valve inlet pressure. p3 is the outlet pressure. p2 is the diaphragm activation pressure, which allows differential pressure p2 p3 to be maintained at a constant value, in order to guarantee the water to at the set value. The minimum differential pressure p p3, required to guarantee the correct value of the set water rate, is indicated in the diagrams on page 7. This is an essential factor to size the system pressure drop and pump pressure head. The rate is kept at a constant value only if the valve pressure drop is higher than the indicated value. Minimum operating differential pressure The minimum differential pressure and the balancing valve pressure drop must be considered to size the system pumps. Flow rate is constant if the pressure drop is higher than that indicated in the diagrams on page 7. The following diagram shows an example of the rate trend according to the pressure drop and calibration required. Example DN Model 6 LEGEND: Qw = rate (l/h) Pd = Min. differential pressure p p3 (bar) Q = Area with inconstant water Q2 = Area with constant water S = Position of the adjustment valve plunger M = Position of the knob

Accessories The valve upstream-downstream minimum differential pressure ( p p3 ), which depends on the valve calibration value, must be exceeded to access the constant rate field. DN Model DN 20 Model LEGEND: Pd = Min. differential pressure p p3 (bar) E.g., when sizing the system pump, in which the DN valves will be installed and in which 40 l/h are constantly required for each device, consider a useful pressure of 0.3 bar (to compensate the pressure drop of the valve) for each balancing valve. Therefore, the pressure drop values produced by the system balancing valves must be summed and the pump must be sized to produce a pressure equal to or greater than the value obtained previously. Benefits Reduced dimensions. Easy installation on 2 or 4 pipe devices. Pre-regulation of the nominal value set even with installed actuator. Easy display of the nominal value set. Nominal values are indicated in 0 l/h without any conversion. Guarantee of constant rate set even with partial loads. Pre-regulation can be blocked and leaded with the locking ring. Technical features DN Model Flow Rate Range (l/h) vs DN 0 00,8 DN 20 80 300 2, Operation limits of the balancing valves Maximum operating temperature 20 C Maximum operating pressure 6 bar Maximum % of water/glycol mixture 0% Minimum operating temperature -0 C Maximum differential pressure 4 bar 7

Accessories Balancing valves for main coil 2 way valve for main coil and assembly kit. The valve is supplied equipped with 230 Volt electro-thermal actuator for the ON/OFF control. S 0 - - 2-3 28 62 3/4 (A) 3/4 (B) 3/4 (B) 3 0 3/4 (A) S 4 S - 6 449 360 464 360 3/4 (B) (B) 3/4 (A) (A) (B) 3/4 (B) 60 6 3/4 (A) 3/4 (A) LEGEND A = inlet - Female connection B = outlet - Male connection Model 0 2 3 4 6 DN Ø VALVE Flow Rate Range (l/h) Code FITTED Identification Code 3/4 0 00 907977 V2OVS6BPM 0-00 907976 3/4 0 00 907979 V2OVS8BPM 0-00 907978 20 80 300 9079792 V2OVS8BPM 80-300 9079782 NOT FITTED Identification V2OVS6BPS 0-00 V2OVS8BPS 0-00 V2OVS8BPS 80-300 8

Accessories Balancing valves for main and additional coil 2 way valve for additional coil and assembly kit. The valve is supplied equipped with 230 Volt electro-thermal actuator for the ON/OFF control. S 0 - - 2-3 28 82 62 3/4 (A) 3/4 (C) 3/4 (D) 3 0 6 3/4 (C) 3/4 (A) 3/4 (B) S 4 S - 6 446 360 324 3/4 (C) 463 446 360 324 (C) 3/4 (A) 3/4 (A) 3/4 (B) (B) 60 27 7 27 7 3/4 (D) LEGEND A = inlet (main coil) - Female connection B = outlet (main coil) - Male connection 446 463 C = inlet (additional coil) - Female connection D = outlet (additional coil) - Male connection 3/4 (D) Coil Main Additional Model 0 2 3 4 6 0 2 3 4 6 DN Ø VALVE Flow Rate Range (l/h) Code FITTED Identification Code 3/4 0 00 907977 V2OVS6BPM 0-00 907976 3/4 0 00 907979 V2OVS8BPM 0-00 907978 20 80 300 9079792 V2OVS8BPM 80-300 9079782 3/4 0 00 9079773 V2OVS6BAM 0-00 9079763 3/4 0 00 9079793 V2OVS8BAM 0-00 9079783 NOT FITTED Identification V2OVS6BPS 0-00 V2OVS8BPS 0-00 V2OVS8BPS 80-300 V2OVS6BAS 0-00 V2OVS8BAS 0-00 9

Crystall Introduction Cassette can be equipped with the innovative plate type electrostatic filter, Crystall, combining air treatment and purifying in a single product. The electronic filter is patented and certified according to Standard UNI 24. Dimensions S 0 / / 2 / 3 (Model 600 x 600) S 4 / / 6 (Model 800 x 800) 20

Crystall Operating principle of the electrostatic filter When the polluted air goes through the mechanical pre-filter the particles 0 µ are eliminated (powder, insects, etc). OUTLET OF CLEAN AIR Collection surface Then the smallest particles (0 0.0 μm) are exposed to an intensive ionizing field and are polarized (Phase ). Air without particles < µm PHASE 2 Inducted anode Polarized electrode The charged particles passing through the second filter section, are pushed back by the anode and attracted to the collection surfaces by a strong, induced magnetic field (Phase 2). The air which leaves the unit is free from polluting particles. Electrostatic filter Air without particles 0 µm Pre-filter PHASE Ionic field Elimination of the biggest particles INLET OF POLLUTED AIR Indoor air quality (IAQ) The expression Indoor Air Quality (IAQ) covers all the procedures and methodologies used to improve the quality of the air we breathe in the places where we live and work, from all points of view, from temperature to cleanliness, to relative humidity, etc. (EN 2 and EN 3779). Thanks to its new patented electronic filter, the Crystall electrostatic filter totally eliminates the pollutants present in the air, including tobacco smoke, dust (PM0, PM2.), fibres, microbiological substances such as bacteria, fungi, etc., which are harmful to human health (source: OMS 2009). Purifying the air means not only greater well-being, but also energy saving, as the fresh air changes that are required to restore ideal climatic conditions and that entail greater consumption, are significantly reduced (it is sufficient to enter the quantity of air required to restore the optimum level of CO 2 - source: EN 379:2008). Moreover, according to the UNI 0339rev, air recirculated by the Crystall appliance can be considered as fresh air, to be added to the minimum requirements (0, ls/m2). Purifying the air with the Sabiana Crystall appliance also entails no reduction of living room space, as the dimensions of the fan convector are practically unchanged (just 3 cm higher). The positioning of the electronic filter allows simple and effective maintenance and, as it is easy to wash, its working life is practically unlimited. The modularity of the filter components and their ease of mounting make the system extremely competitive in terms of cost compared with other types of filters present on the market. In spring and autumn, if air conditioning/heating is not required, the appliance acts simply as an air purifier. Standards and legislation THE AMBIENT CONDITION IS ACCEPTABLE WHEN: Microclimatic parameters are normal 80% of people are satisfied by the quality of air Specific internal contaminants are not in harmful concentrations Guidelines for the protection and promotion of health in confined areas O.G. No. 276 dated 27 Nov 0 ordinary supplement no. 22 The method for obtaining the air quality required in confined areas and thus succeeding in ensuring that the contaminants present are in concentrations less than those considered dangerous to health are: Prescriptive approach: ventilation of the internal area using only properly filtered fresh air, in the quantity and quality needed to dilute the internal contaminants in order to reach the required maximum acceptable concentration values (see WHO limits). Performance approach: ventilation with fresh air and recirculated air from the same area, both properly filtered, in the quantity and quality needed to dilute the internal contaminants in order to reach the required maximum acceptable concentration values (see WHO limits). 2

Crystall The quantity and quality of recirculated air and outdoor air to be added is better specified in the prescriptive and performance approach in Standards UNI EN 3779:2008 and soon to be released UNI 0339rev according to the following simplified tables. UNI EN 3779:2008 Prescriptive Method Category IDA IDA 2 IDA 3 IDA 4 Category ium not classified Unit l.s. person l.s. person l.s. person l.s. person UNI EN 0339rev (l.s. per person) + (l.s. per m 2 ) (l.s. per person) + (l.s. per m 2 ) (l.s. per person) + (l.s. per m 2 ) not classified Tipical range > 0 6 0 < 6 Rate of fresh air Rate of fresh air Default value 20 2, 8 Total fresh air volume varies based on the intended use of the confined area UNI EN 3779:2008 Identification and quantification of the reference pollutant (PM or gas) Performance Method Concentration Limit WHO publicized values and legislative acts expressed in µg/m 3, PPM, etc. Concentration Limit WHO publicized values and legislative acts expressed in µg/m 3, PPM, etc. Minimum fresh air l.s. person - 6 UNI EN 0339rev Minimum fresh air l.s. person The minimum volume of air input varies based on the intended use of the confined area Quantity of recirculated air provided that it is filtered like fresh air The volume of air to be considered is based on the internal production and the imposed concentration limits in the confined area Identification and quantification of the reference pollutant (PM or gas) Quantity of recirculated air provided that it is filtered like fresh air The volume of air to be considered is based on the internal production and the imposed concentration limits in the confined area Fresh air rates according to the performance approach UNI EN 3779:2008 and UNI 0339rev Standards The example reproduced at the bottom of the page shows how, with adequate air filtering, it is possible to decrease considerably the quantity of fresh air to be brought into the environment (up to 3-4 times less); the thermal energy dissipated due to ventilation is in fact in direct proportion to the number of air changes, as indicated in the following equation: Qv = T R D C Vol. 3600 Qv = Thermal energy lost for ventilation - Watt T = Indoor-Outdoor difference (T) - C R = A.C.H. D = Air density - g/m 3 C = Specific air heat - J/g- C Vol = Room size - m 3 22

Crystall Construction features The Crystall electrostatic filtering system consists of two parts: the first is a plate type electronic active filter and is fitted in the return air section of the cassette, while the second is an electronic control and regulation board, fixed on the structure. All electrical connections are made during production. The installation of the Sabiana cassette fan coil unit incorporating the Crystall electronic filter is therefore similar to that of a normal unit: the only difference is the installation height, for which the filter dimensions must taken into account. Crystall filters are not suitable for ECM and electric heater versions. Active plate type electronic filter The filtering element consists of two sections: the first consists of electrodes and insulating elements, forming a self-supporting ionising frame, while the second consists of special light aluminium fins (collector). The two sections are installed above the return air grille to make the extraction and maintenance of the filter easier. Accessibility to sections to be cleaned is ensured by easy-open plastic closures. The collector can be cleaned by washing with water and ordinary detergents or steam jets (please consult the maintenance manual for further details). Electronic board Controls and regulates all functions of the electrostatic filter. It is appropriately protected against any operating defects of the electrostatic filter. It supplies a constant voltage to the electrodes when the mains supply voltage varies (± %). The supply transformer is constructed with its primary and secondary coils physically separated and wound onto separate cores. The energy consumption of the filter group is 2 W (to which the electrical consumption of the Cassette must be added). Control and regulation commands Units with Crystall electrostatic filter can be controlled and regulated by the series of IAQ controls that are already provided for CRC Carisma fan coils. - Diffuser with return air grid 2 - Active plate type electrostatic filter 3 - Plastic opening 4 - Insulation - Filter containment frame 6 - Electronic board 7 - Cassette 23

Wall electronic controls All the units can be supplied with a wide range of controls that allows managing one single unit or several units (by using speed switches or the power unit). The room temperature can be controlled through electronic room thermostats, with different solutions according to every ambient conditions. The options range from the basic 3 speed control WM-3V to the highly sophisticated WM-T and WM-TQR electronic room thermostats that regulate the room temperature and are suitable when the user wants to set the fan speed. The most evolved WM-AU, T-MB, TMO-03-SV2 and FreeSabiana versions allow both the manual and the automatic speed switch. WM-3V WM-T WM-TQR WM-AU T-MB TMO-03-SV2 T2T FreeSabiana wireless control All the controls are described in detail in the Fan Coil Control Range literature. 24

Controls for S MB versions All the units can be supplied in MB version. This version includes a wide range of controls, including the infra-red remote control, which allows managing one single unit or several units by using the Modbus RTU - RS 48 communication protocol. Units can be managed according to the Master/Slave logic (up to 20 units) or by supervisory components. The system consists in a MB board (mounted on models S MB and S ECM MB) and a series of controls, such as the T-MB wall control, the RT03 infra-red remote control, the PSM-DI multifunction control and the Sabianet supervisory program. T-MB wall control PSM-DI multifunction control Sabianet screenshot PC RT03 infra-red remote control Sabianet software All the controls are described in detail in the Fan Coil Control Range literature. 2

Electric heater S-E The Cassette 2 pipe models are available with electric resistance that is controlled in place of the heating battery valve. The electric resistance is controlled in place of the hot water valve and not as integration to it. The resistance is hermetically sealed and supplied inside the battery pipes and therefore can be only factory mounted. The electric resistances of the units are for single phase 230V supply. The Cassette includes no. 2 safety thermostats which intervene in case of internal over- heating, opening an auxiliary power relay (included in the shunt box) which stops the power supply to the resistances. Model Supply Number and Dia. of connecting wires S 2-E S 22-E / S 32-E S 42-E / S 2-E / S 62-E 00 Watt 230V ~ 3 x, mm 2 200 Watt 230V ~ 3 x 2, mm 2 3000 Watt 230V ~ 3 x 2, mm 2 Note: the cooling emission of the units is 9% of the emission in the tables of page 6. Electric diagram T POWER SUPPLY 230Vac 0Hz PE Q L N TS TS2 B 2 N L 3 M3 4 6 7 M7 B B BN OG WH 2 -level ALARM 8 M9 J3 J 9 0 M B BN BU J Thermostat ALARM BU BN J4 SEC WH WH 23 4 M6 C...... MM L M RD OG M EH M0 M9 M8 B V V2 V3 J2 V M4 V2 V3 2 L3 N L2 N L N L3 M2 L2 L M L N 3 4 R3 R2 R POWER SUPPLY 230Vac 0Hz Q2 L N LEGEND: M = Fan SEC = Fan coil terminal board T C = Autotransformer = Capacitor B = Condensate level sensor M9 = pump motor S = Alarm condensate contact E = Cold water valve B = Black BN = Brown BU = Dark Blue OG = Orange RD = Red WH = White R-R2-R3 = Resistance Q-Q2 = Two poles disconnector 2 3 4 Input for electric resistance Input for E speed ium speed E speed TS TS2 Safety thermostat TS TS2 Thermal cut Off = 4 C Thermal cut Off = 80 C Automatic Reset Manual Reset Cassette unit operating limits with electric coil Max. ambient temperature for Cassette unit with electric coil in heating mode: 2 C 26

ECM / ECM 27

ECM ECM Introduction The ECM series uses an innovative brushless synchronous permanent magnet electric motor controlled by an inverter card that is directly installed on the unit. The air can be varied continuously with a -0 V signal from Sabiana controls or by independent contollers (programmable controllers with a -0 V output). The extreme efficiency, also at a low speed, makes possible a great reduction in electric consumption (more than 7% less in comparison to a traditional motor) with absorption values, under normal operating conditions, that are no greater than 0 Watt in the entire range. The brushless motor is characterised by a constant synchronous speed, independently of the applied load, that depends only on the motor power supply frequency, which is modulated by the inverter. It consumes less because: The motor always works at its point of maximum efficiency. In the brushless motor, the rotor s permanent magnets generate the magnetising power autonomously. The motor always operates at the synchronous speed, as a result there are no induced currents that reduce efficiency. The main advantages are: Large reduction in energy consumption, thanks to an optimal response to the thermal load of the environment during every moment of the day. Operating silence at all rotation speeds. Ability to operate at any rotation speed. Motor Absorption = S = S-ECM 28

ECM ECM Main components INTAE GRID AND DISTRIBUTION OF THE AIR Intake grids, frame and adjustable air distribution louvers on each side, made from ABS. HTA version : white ABS, RAL 9003 HTB version : with intake grid, frame and louvers, choice of one colour only HTC version : with intake grid and louvers, choice of one colour, plus white ABS frame RAL 9003 HTD version : with louvers, choice of one colour, while the grid and frame are made from ABS, RAL 9003 MD-600 version : metal diffuser painted in RAL 9003 white colour with 600x600 dimension to perfectly fit into the false ceiling standard modules without overlapping parts (800x800 model is not available). CASING Is made from galvanized steel with internal thermal insulation with polyolefin (PO) foam (class M) and external anti-condensate lining. CONTROL EQUIPMENT S ECM version It consists of the pump control circuit board and the inverter circuit board. S ECM MB version It consists of the MB electronic board (that integrates pump control) and the inverter board. FAN ASSEMBLY The fan assembly, which is mounted on anti-vibrating supports, is extremely silent. The radial fan has been designed to optimise performance, using wing profile blades with a shape that reduces turbulence, increasing efficiency and reducing noise. The fans are connected to a three phase permanent magnet brushless electronic motor that is controlled with reconstructed current according to a BLAC sinusoidal wave. The inverter board that controls the motor operation is powered by 230 Volt, single-phase and, with a switching system, it generates a three-phase frequency modulated, wave form power supply. The electric power supply required for the machine is therefore single-phase with voltage of 230-240 V and frequency of 0-60 Hz. COIL Made of copper tubes with bonded aluminium fins for maximum transfer contact. The coil has 2 or 3 rows for 2 pipe models and 2+ rows for 4 pipe models (the heating row is on the inside part of the coil). For 4 pipe systems two versions are available: S 4 and S 44 supply an higher heating emission; S 26, S 36, S 6 supply an higher cooling emission. The heat exchanger is not suitable for use in corrosive atmosphere or in environments where aluminium may be subject to corrosion. CONDENSATE COLLECTION TRAY density ABS polystyrene foam condensate tray, shaped in order to optimize the air diffusion, fire retardant rating B to DIN 402. AIR FILTER Synthetic washable filter, easily removable. CONDENSATE PUMP Float switch centrifugal pump with 60 mm of maximum head, integral to the unit and wired to the control panel on the outside of the casing. VALVE SET Two or three way valves for ON/OFF operation, with pipe mounting kit and thermostatic actuator. 29

ECM ECM EUROVENT Certification www.eurovent-certification.com Technical features 2 pipe units. The following standard rating conditions are used: COOLING Entering air temperature: + 27 C d.b., + 9 C w.b. temperature: + 7/2 C HEATING Entering air temperature: + 20 C temperature: + 0 C water rate as for the cooling conditions MODEL S-ECM 2 S-ECM 22 S-ECM 32 S-ECM 42 S-ECM 2 Inverter Power Vdc 0 0 0 0 0 Speed 2 3 2 3 2 3 2 3 2 3 Air m 3 /h 30 380 3 30 44 360 60 880 630 870 6 30 770 Cooling total emission (E) kw,84 2,7 2,7 2,24 3,0 4,33 2,6 3,87,02 4,2, 6,33,29 7,72 0,7 Cooling sensible emission (E) kw,3,6 2,09,7 2,7 3,8,8 2,8 3,74 3,03 3,77 4,72 3,69,3 7,94 Heating (E) kw 2,22 2,67 3,44 2, 3,8,24 2,96 4,63 6,2, 6,3 8,0,89 8,83 2,73 l/h 37 373 473 38 24 744 44 666 864 723 88 089 909 328 848 P Cooling (E) kpa 4,9 6,6 0, 4,6 9,4,,9 2,4 9,7 0,9,6 22,7 9,4 8, 33,6 P Heating (E) kpa 4, 8,7 3,6 6,6 3, 4,7 0, 7,7 8,7 2,8 9, 7,2 4,9 28,8 Sound power Lw (E) db(a) 33 39 47 33 43 4 37 0 60 33 39 48 34 47 7 Sound pressure Lp ( * ) db(a) 24 30 38 24 34 4 28 4 24 30 39 2 38 48 Fan (E) W 8 6 3 7 2 62 0 7 33 0 32 08 content l,4 2, 2, 3,0 4,0 Dimensions mm 7 x 7 x 27 820 x 820 x 303 4 pipe units. The following standard rating conditions are used: COOLING Entering air temperature: + 27 C d.b., + 9 C w.b. temperature: + 7/2 C HEATING Entering air temperature: + 20 C temperature: + 70/60 C MODEL S-ECM 4 S-ECM 26 S-ECM 36 S-ECM 44 S-ECM 6 Inverter Power Vdc 0 0 0 0 0 2 3 Speed 2 3 2 3 2 3 2 3 Air m 3 /h 30 380 3 30 44 360 60 880 630 870 6 30 Cooling total emission (E) kw,8 2,8 2,77 2,09 2,8 3,93 2,38 3,3 4,3 4,3,28 6, 4,98 7,7 Cooling sensible emission (E) kw,34,6 2,08,49 2,04 2,9,7 2,62 3,46 3,08 3,84 4,83 3,2,2 l/h 38 37 476 39 483 676 409 608 779 740 908 20 86 233 P Cooling (E) kpa 4,6 6,2 9, 3,,7 0, 4, 8,4 3, 9,4 3,6 9,8 8,8 7 Heating (E) kw 2,43 2,8 3,62,98 2,3 3,3 2,2 3,06 3,79 6,4 7,4 9,36,22 7,6 l/h 209 24 3 70 27 288 89 263 326 28 649 80 449 66 P Heating (E) kpa,7 7,6,7 3,, 9 4, 7, 0,, 22, 6, Sound power Lw (E) db(a) 33 39 47 33 43 4 37 0 60 33 39 48 34 47 Sound pressure Lp ( * ) db(a) 24 30 38 24 34 4 28 4 24 30 39 2 38 Fan (E) W 8 6 3 7 2 62 0 7 33 0 32 Cooling water content l,4,7,7 3,0 3,6 Heating water content l 0,7 0, 0,,4, Dimensions mm 7 x 7 x 27 820 x 820 x 303 Condensate pump absorption: 0 W (E) = Eurovent certified performance. * = The sound pressure levels are 9 db(a) lower than the sound power levels and apply to the reverberant field of a 00 m 3 room and a reverberation time of 0. sec. 770 9,87 7,4 697 30, 9, 88 8 7 48 08 30

ECM ECM Cooling emission of battery units (2 pipe installation) Entering air temperature: +27 C d.b. +9 C w.b. ECM Mod. S 2 S 22 S 32 S 42 S 2 Speed Vdc 0 0 0 0 0 Air m 3 /h 3 380 30 44 30 880 60 360 6 870 630 770 30 EWT - LWT 0 C EWT 7 - LWT 2 C EWT 9 - LWT 4 C EWT 2 - LWT 7 C Total Sensible emission emission l/h kw kw 70 448 379 888 62 43 03 793 20 304 0 89 220 74 068 3,32 2,60 2,2,7 3,6 2,63 6,02 4,6 3,02 7,8 6,3 4,99 2,8 9, 6,2 2,33,80, 3, 2,43,7 4,8 3, 2,02,27 4,2 3,39 8,88 6,8 4,2 Total Sensible emission emission l/h kw kw 473 373 37 744 24 38 864 666 44 089 88 723 848 328 909 2,7 2,7,84 4,33 3,0 2,24,02 3,87 2,6 6,33, 4,2 0,7 7,72,29 2,09,6,3 3,8 2,7,7 3,74 2,8,8 4,72 3,77 3,03 7,94,3 3,69 Total Sensible emission emission l/h kw kw 368 293 20 88 49 3 678 28 34 87 70 76 46 09 734 2,4,70,4 3,42 2,43,8 3,94 3,07 2,06 4,98 4,07 3,3 8,47 6,6 4,27,84,42,8 2,80,9,38 3,30 2,48,9 4,7 3,32 2,67 7,00 4,86 3,24 Total Sensible emission emission l/h kw kw 266 207 74 40 28 204 482 363 23 604 483 392 03 78 482,4,2,0 2,38,63,8 2,80 2,,37 3, 2,8 2,28,99 4,8 2,80,4,2,0 2,38,63,8 2,80 2,,37 3, 2,8 2,28,99 4,8 2,80 Heating emission of battery units (2 pipe installation) Entering air temperature: +20 C ECM Mod. S 2 S 22 S 32 S 42 S 2 Speed Vdc 0 0 0 0 0 Air m 3 /h 3 380 30 44 30 880 60 360 6 870 630 770 30 EWT 4 - LWT 40 C EWT 0 - LWT 40 C EWT - LWT 4 C EWT 60 - LWT 0 C EWT 70 - LWT 60 C l/h 493 383 38 749 2 36 886 663 423 2 92 734 87 262 842 kw 2,87 2,22,8 4,36 2,98 2,2, 3,8 2,46 6,70,30 4,27 0,6 7,34 4,90 l/h 272 23 78 420 290 209 494 373 24 642 2 4 0 73 48 kw 3,7 2,48 2,07 4,89 3,38 2,43,7 4,34 2,8 7,47,9 4,82,8 8,29,60 l/h 330 27 24 0 347 249 9 448 288 774 6 497 222 84 74 kw 3,83 2,99 2,49,87 4,04 2,90 6,92,20 3,3 9,00 7,,78 4,2 9,93 6,67 l/h 387 300 20 89 404 289 696 22 33 904 77 78 428 994 666 kw 4,49 3,49 2,9 6,8 4,70 3,36 8,09 6,07 3,89 0, 8,34 6,72 6,60,6 7,74 l/h 00 387 322 78 7 368 896 670 427 6 922 74 837 274 849 kw,82 4, 3,7 8,8 6,0 4,28 0,42 7,79 4,96 3,4 0,72 8,6 2,37 4,82 9,87 correction factors for different working conditions. Multiply the factors by the emission figures in the 7-2 C table above. Total emission Sensible emission Note: ( C) Air ( C) 2-8 26-8. 28-20 ( C) Air ( C) 2-8 26-8. 28-20 7/2 C 0/ C 4/8 C 0,82 0,6 0,3 0,89 0,63 0,4, 0,82 0,2 7/2 C 0/ C 4/8 C 0,9 0,72 0, 0,94 0,78 0,8,06 0,9 0,72 the correction factors are indicative, as they are average values. 3

ECM ECM of 4 pipe units with standard and enhanced cooling battery Cooling emission of 2 battery units (4 pipe installation) Entering air temperature: +27 C d.b. +9 C w.b. ECM Mod. S 4 S 26 S 36 S 44 S 6 Speed Vdc 0 0 0 0 0 Air m 3 /h 3 380 30 44 30 880 60 360 6 870 630 770 30 EWT - LWT 0 C EWT 7 - LWT 2 C EWT 9 - LWT 4 C EWT 2 - LWT 7 C Total Sensible emission emission l/h kw kw 72 448 378 82 76 42 940 729 486 34 08 877 203 467 00 3,32 2,6 2,20 4,72 3,3 2,47,46 4,24 2,82 7,79 6,29,0,83 8,3,87 2,32,79,0 3,29 2,28,66 3,86 2,93,9,40 4,30 3,4 8,26,82 3,93 Total Sensible emission emission l/h kw kw 476 37 38 676 483 39 779 608 409 20 908 740 697 233 86 2,77 2,8,8 3,93 2,8 2,09 4,3 3,3 2,38 6,,28 4,30 9,87 7,7 4,98 2,08,60,34 2,9 2,04,49 3,46 2,62,7 4,83 3,84 3,08 7,40,20 3,2 Total Sensible emission emission l/h kw kw 372 296 22 28 382 287 606 477 32 882 79 90 332 979 687 2,7,72,46 3,07 2,22,67 3,2 2,77,89,3 4,8 3,43 7,74,69 3,99,83,4,8 2,60,79,3 3,0 2,3,0 4,26 3,38 2,7 6,3 4,8 3,09 Total Sensible emission emission l/h kw kw 264 206 72 378 262 92 442 337 22 69 497 398 9 672 47,4,20,00 2,20,3,2 2,7,96,29 3,6 2,89 2,32,3 3,90 2,66,4,20,00 2,20,3,2 2,7,96,29 3,6 2,89 2,32,3 3,90 2,66 Heating emission of 2 battery units (4 pipe installation) Entering air temperature: +20 C ECM Mod. S 4 S 26 S 36 S 44 S 6 Speed Vdc 0 0 0 0 0 Air m 3 /h 3 380 30 44 30 880 60 360 6 870 630 770 30 EWT 4 - LWT 40 C EWT 0 - LWT 40 C EWT - LWT 4 C EWT 60 - LWT 0 C EWT 70 - LWT 60 C l/h 30 24 20 279 2 6 3 2 84 793 639 2 800 603 440 kw,78,40,9,62,23 0,96,83,48,07 4,6 3,72 3,03 4,6 3,0 2,6 l/h 6 27 08 39 06 83 6 27 93 42 340 278 43 32 229 kw,87,48,26,6,23 0,97,82,48,08 4,90 3,96 3,23 4,80 3,63 2,67 l/h 98 6 33 76 33 0 98 6 7 7 47 340 4 388 284 kw 2,30,82, 2,04,,22 2,3,87,36 6,0 4,8 3,96,97 4, 3,30 l/h 236 86 8 23 6 27 24 9 4 63 494 403 6 464 339 kw 2,74 2,6,84 2,48,87,47 2,80 2,27,64 7,3,7 4,68 7,,39 3,94 l/h 3 24 209 288 27 70 326 263 89 80 649 28 88 66 449 kw 3,62 2,8 2,43 3,3 2,3,98 3,79 3,06 2,20 9,36 7,4 6,4 9, 7,6,22 correction factors for different working conditions. Multiply the factors by the emission figures in the 7-2 C table above. Total emission Sensible emission Note: ( C) Air ( C) 2-8 26-8. 28-20 ( C) Air ( C) 2-8 26-8. 28-20 32 7/2 C 0/ C 4/8 C 0,82 0,6 0,3 0,89 0,63 0,4, 0,82 0,2 7/2 C 0/ C 4/8 C 0,9 0,72 0, 0,94 0,78 0,8,06 0,9 0,72 the correction factors are indicative, as they are average values.

ECM ECM side pressure drop 2 pipe installation Pressure drop for mean water temperature of 0 C, for different temperatures multiply the pressure drop figure by the correction factors in the table. C 20 30 40 0 60 70 80 0,94 0,90 0,86 0,82 0,78 0,74 0,70 (l/h) 4 pipe installation Pressure drop for cooling battery Pressure drop for heating battery Pressure drop (kpa) Pressure drop (kpa) Pressure drop (kpa) (l/h) Pressure drop for mean water temperature of 0 C, for different temperatures multiply the pressure drop figure by the correction factors in the table. (l/h) Pressure drop for mean water temperature of 6 C, for different temperatures multiply the pressure drop figure by the correction factors in the table. C 20 30 40 0 60 70 80 C 40 0 60 70 80 0,94 0,90 0,86 0,82 0,78 0,74 0,70,4,08,02 0,96 0,90 Working conditions MAX. working pressure 8 bars Air Suitable relative humidity - 7% Supply Single phase 230V 0Hz Installation MAX. height: See table on page 2 MIN. entering water temperature: + C MAX. entering water temperature: + 80 C MIN. entering air temperature: 6 C MAX. entering air temperature: 40 C 33

ECM ECM Dimensions and weights S 2-4 / S 22-26 / S 32-36 (Version 600 x 600) 2 pipe units - 3. Flow, heating/cooling /2-4. Return, heating/cooling /2 4 pipe units -. Flow, heating /2-2. Return, heating /2-3. Flow, cooling /2-4. Return, cooling /2 MD-600 / MD-800 METAL DIFFUSER (RS receiver, Code 9066338, for metal diffuser for MB units) Size MD-600 MD-800 A B C 99 880 74 84 34, 4, Code 9079420 907947 ECM Model S 2 S 4 S 22-26 S 32-36 UNIT Weights Weights packed unit unpacked unit kg kg 28 22 30 24 DIFFUSER Weights Weights packed unit unpacked unit kg kg 6 3 Packed unit Dimensions A B C D mm 790 30 70 0 34

ECM ECM Dimensions and weights S 42-44 / S 2-6 (Version 800 x 800) 2 pipe units - 3. Flow, heating/cooling 3/4-4. Return, heating/cooling 3/4 4 pipe units -. Flow, heating /2-2. Return, heating /2-3. Flow, cooling 3/4-4. Return, cooling 3/4 PACED UNIT UNIT DIFFUSER ECM Model S 42 S 44 S 2-6 UNIT Weights Weights packed unit unpacked unit kg kg 44 36 47 39 DIFFUSER Weights Weights packed unit unpacked unit kg kg 0 6 Packed unit Dimensions A B C D mm 00 400 000 200 3

ECM ECM Air throw The air throw indicated in the tables must only be considered the maximum value, as it may change significantly in relation to the dimensions of the room in which the appliance is installed and the positioning of the furniture in the room. The useful throw L refers to the distance between the unit and the point where the air speed is 0.2 m/sec; if the louver has a gradient of 30 (recommended in cooling mode), the so-called Coanda effect will occur, illustrated in the first figure, while at a gradient of 4 (recommended in heating mode), there will be a downwards throw, as illustrated in the second figure. With adjustable air diffusion louvers at 30 ECM Model Speed Air throw L m S 2-4 S 22-26 S 32-36 S 42-44 S 2-6 2 3 3,0 3, 3,8 2 3 3,0 3,8 4, 2 3 3, 4,2,0 2 3 3,2 3,7 4,3 2 3 3,4 4,0,0 With adjustable air diffusion louvers at 4 ECM Model Speed Air throw L m Height H m Distance B m S 2-4 S 22-26 S 32-36 S 42-44 S 2-6 2 3 2 3 2 3 2 3 2 3 3,3 2,2 2, 3,9 2,6 2,9 4,2 2,8 3, 3,3 2,2 2, 4,2 2,8 3, 4,8 3,2 3,6 3,9 2,6 2,9 4, 3,0 3,4,2 3,4 3,9 3, 2,2 2,7 4, 2,6 3,2 4,8 3,0 3,8 3,8 2,4 3,0 4,6 2,8 3,6,4 3,4 4,2 NOTE: On heating it must be payed attention to rooms where the floor temperature is particularly low (for example less than C). In this situation the floor can cool the lower layer of air to a level that stop the uniform diffusion of the hot air coming from the unit, decreasing the throw figures shown in the table. 36

ECM ECM Accessories Fresh air connection See page 3. Identification Code CAP 607800 Air distribution connection See page 3. Identification Code CDA 600 9079232 CDA 800 9079233 The diameter of the fitting is 0 mm for S - 2-3 and 80 mm for S 4 -. Fresh air kit This is used to introduce fresh air into the environment directly through the diffuser. The kit includes a separator to be fitted inside the cassette, and a circular fitting for connection to the flexible system ducting. The of air is sent directly to just one of the outlet louvers, without passing through the coil. The air of fresh air introduced Model Identification S -2-3 PRT 600 S 4- PRT 800 into the environment depend on the inlet static pressure. 9079230 907923 Code Correlation between -rate / static pressure S -2-3 S 4- m 3 /h Pa m 3 /h Pa 80 20 60 200 240 3 8 2 36 60 200 300 400 00 3 8 2 36 The diameter of the fitting is 0 mm for S - 2-3 and 80 mm for S 4 -. 37

ECM ECM ON-OFF valves with thermoelectric actuator Valve with Micrometric Lockshield Valve 3 ways 2 ways Valve with Simplified it 3 ways 2 ways Technical data: Rated pressure: Max. ambient temperature: Max. water temperature: Power: Rating: Protection: Travel time: Max. glycol content of water: p - kpa 6 bar 0 C 0 C 230 V - 0/60 Hz 3 VA IP 43 approx. 3 min. 0% Valves characteristics Battery type Main Auxiliary ECM Model 2-22 - 32 4-26 - 36 42-2 44-6 4-26 - 36 44-6 vs m 3 /h 2,8,2 2,8 2 way valves 3 way valves pmax kpa * 0 60 0 Valve ** connection 3/4" " 3/4" vs m 3 /h 2, 4, 2, pmax kpa * * maximum pressure difference for valve to close ** external thread, flat seal Note: 3 way valves with simplified kit and connection have conical seal. 0 0 0 Valve ** connection 3/4" " 3/4" Valves pressure drop (l/h) Valve set, 2 or 3 ways, ON-OFF, with thermoelectric actuator. The set includes connection pipes. Note: The main battery lockshield valve connection is /2 female (vs 2) for S - S2 - S3 sizes and 3/4 female (vs 3,) for S4 - S sizes, the auxiliary battery valve connection is /2 female (vs 2). Note: The maximum pressure drop accross the fully open valve should not exceed 2 kpa for cooling operation and kpa for heating operation. For 2 way balance valve, refer to page 6. 38

ECM ECM S ECM configuration For this cassette configuration, the -0 Vdc signal, which controls the inverter, must be supplied by a controller with the following signal specifications: Impedance < 00 Ω; Maximum speed 0Vdc; Fan OFF with V < 0.9Vdc. S ECM electric diagram LEGEND SEP = Pump control board BLAC = Inverter board M = Electronic motor CONTROLLER = Controller 39

ECM ECM Wall electronic controls All the units can be supplied with a wide range of controls that allows managing one single unit or several units (by using the power unit). The room temperature can be controlled through electronic room thermostats, with different solutions according to every ambient conditions. The electronic thermostats WM-AU, T-MB and WM-S-ECM rule the room temperature precisely and are suitable for each of those situations, into which it is the user to decide between the manual or the automatic fan speed. WM-AU T-MB WM-S-ECM All the controls are described in detail in the Fan Coil Control Range literature. 40

ECM ECM Controls for S ECM MB versions All the ECM units can be supplied in MB version. This version includes a wide range of controls, including the infra-red remote control, which allows managing one single unit or several units by using the Modbus RTU - RS 48 communication protocol. Units can be managed according to the Master/Slave logic (up to 20 units) or by supervisory components. The system consists in a MB board (mounted on models S MB and S ECM MB) and a series of controls, such as the T-MB wall control, the RT03 infra-red remote control, the PSM-DI multifunction control and the Sabianet supervisory program. T-MB wall control PSM-DI multifunction control Sabianet screenshot PC RT03 infra-red remote control Sabianet software All the controls are described in detail in the Fan Coil Control Range literature. 4

ECM ECM Electric heater S-ECM-E The Cassette 2 pipe models are available with electric resistance that is controlled in place of the heating battery valve. The electric resistance is controlled in place of the hot water valve and not as integration to it. The resistance is hermetically sealed and supplied inside the battery pipes and therefore can be only factory mounted. The electric resistances of the units are for single phase 230V supply. The Cassette includes no. 2 safety thermostats which intervene in case of internal over- heating, opening an auxiliary power relay (included in the shunt box) which stops the power supply to the resistances. ECM Model Supply Number and Dia. of connecting wires S 2-E S 22-E / S 32-E S 42-E / S 2-E / S 62-E 00 Watt 230V ~ 3 x, mm 2 200 Watt 230V ~ 3 x 2, mm 2 3000 Watt 230V ~ 3 x 2, mm 2 Note: the cooling emission of the units is 9% of the emission in the tables of page 3. Electric diagram POWER SUPPLY 230Vac 0Hz L N B M9 LEGEND: Q PE GNYE BN BU BU BN TS2 BN TS 2 N L 3 M3 4 6 7 M7 B B BN OG WH 2 J3 J -level ALARM BLAC J SEC Thermostat ALARM E J4 8 9 0 23 4 M6 M V V2 V3 J2 V M4 V2 V3 M EH 2 L3 M0 N L2 M9 N M8 L N L3 M2 L2 L M L N R3 R2 R GNYE BU BN BN POWER SUPPLY 230Vac 0Hz L N Q2 M = Fan SEC = Fan coil terminal board BLAC = Inverter circuit board B = Condensate level sensor M9 = pump motor E = Cold water valve B = Black BN = Brown BU = Dark Blue OG = Orange RD = Red WH = White GNYE = Yellow/Green 2 3 Input for electric resistance Input for E Signal 0-0Vdc 0-0Vdc Fan Drive signal 3 P- P+ A- 0 A+ 0VDC PV 0-0 Vdc Input signal N L PE ECM board power supply W V U Tp Tp 3 M PE TS TS2 TS TS2 Safety thermostat Thermal cut Off = 4 C Automatic Reset Thermal cut Off = 80 C Manual Reset GNYE Cassette unit operating limits with electric coil Max. ambient temperature for Cassette unit with electric coil in heating mode: 2 C 42

MCT MCT Introduction The MCT version has been designed for all environments where false ceilings are not featured or cannot be constructed. The cover cabinet fits perfectly to the air intake and outlet diffuser, maintaining the appealing design that defines the series. The water fittings can be turned to point upwards. The MCT series includes 7 models, with an installation height of up to m, thanks to the highly flexible adjustment of the air distribution louvers. All the technical specifications described on the previous pages remain the same, while keeping in mind that: - the MCT series features one coil only (two pipe systems) - there is no possibility of fresh air intake - there is no possibility of additional electric heater The MCT version features a special casing delivered in separate packaging; this must only be fitted after having installed the unit and completed the water and electrical connections. 43

MCT MCT Dimensions and Weights S 02-MCT / S 2-MCT / S 22-MCT / S 32-MCT Casing code: 9079240 Casing weight: kg (7, kg with the packaging) S 42-MCT / S 2-MCT / S 62-MCT Casing code: 907920 Casing weight: 0, kg (3, kg with the packaging) Warning: the electrical and water connections must enter the unit from above and must not interfere with the casing. 44

MCT MCT Assembly diagram 4

MCT MCT Components of the casing: The casing includes: A 4 corner covers B 4 bottom brackets C 4 top brackets D Condensate collection tray E Hardware (4 3.9x9.mm TCX screws) F Instruction sheet Valve kit The valve fittings allow the water pipes to be connected from above. S 02-MCT / S 2-MCT S 22-MCT / S 32-MCT Code 9079 S 42-MCT S 2-MCT / S 62-MCT Code 90796 For the specifications of the valves, see page. The descriptions and illustrations provided in this publication are not binding: Sabiana reserves the right, whilst maintaining the essential characteristics of the types described and illustrated, to make, at any time, without the requirement to promptly update this piece of literature, any changes that it considers useful for the purpose of improvement or for any other manufacturing or commercial requirements. 46