ITT. Goulds Pumps G&L Series Commercial Products. Engineered for life. Commercial Water. Goulds Pumps is a brand of ITT Corporation.

Similar documents
Commercial Products. Pumps Controls Pressure Boosting BRGLCAR R1

Commercial Products PUMPS CONTROLS PRESSURE BOOSTING BRGLCAR R4

AquaBoost. Variable Speed Constant Pressure Systems MODEL ABS

Aquavar e-abii. TECHNICAL BROCHURE BAQUAeABII VARIABLE SPEED CONSTANT PRESSURE SYSTEMS

Aquavar ABII TECHNICAL BROCHURE BAQUABII R2 VARIABLE SPEED CONSTANT PRESSURE SYSTEMS

Variable Speed Product Line

BRAQCPC IT T. Goulds Pumps AQUAVAR CPC. Variable Speed Centrifugal Pump Controller. Engineered for life

Hydrovar and Packaged Hydrovar

TECHNICAL BROCHURE BAQUACPC. Aquavar CPC VARIABLE SPEED CENTRIFUGAL PUMP CONTROLLER

AQUAVAR AQUAVAR 56 AQUAVAR CPC

ITT. Goulds Pumps. AquaForce PRESSURE BOOSTING SIZING GUIDE. Engineered for life. Building and Municipal Applications.

Aquavar SPD Plus SIMPLEX VARIABLE SPEED SUBMERSIBLE AND ABOVE GROUND PUMP CONTROLLER BRSPDP R2

BSPDDRIVE ITT. Goulds Pumps. Aquavar SPD (Single Pump Drive) Simplex Variable Speed Pump Controller

BRSDRIVE ITT. Goulds Pumps. S-Drive. Simplex Variable Speed Submersible Pump Controller. Engineered for life

ITT. Goulds Pumps. G&L Series SSH S & M-Group 316 Stainless Steel End Suction Pumps. Engineered for life. Commercial Water.

TECHNICAL BROCHURE BSPDDRIVE. Aquavar SPD (Single Pump Drive) SIMPLEX VARIABLE SPEED PUMP CONTROLLER FOR SUBMERSIBLE AND CENTRIFUGAL PUMPS

ITT. Goulds Pumps G&L Series NPO. Engineered for life. Commercial Water. Open Impeller All Stainless Steel End Suction Pumps.

AquaBoost Packaged Systems

DPS. The SSV Dual Pump System

ITT. Goulds Pumps. 5GB, 7GB, 10GB, 18GB, 25GB, 33GB High Pressure Multi-Stage Booster Pump. Engineered for life. Residential Water Systems FEATURES

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

5GB, 7GB, 10GB, 18GB, 25GB, 33GB

TECHNICAL BROCHURE BSPMSPH R1 SOLD SEPARATELY OR BUILT IN. PrimeLine SP SPM & SPH SERIES

ITT. Goulds Pumps. Marlow Series 20EVP. Engineered for life. Commercial Water

General Catalog. A New Vision for Quality Pumps. General Catalog

TECHNICAL BROCHURE B5-33GB R4 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

High Capacity Centrifugal & Sprinkler Pumps

HIGH CAPACITY CENTRIFUGAL & SPRINKLER PUMPS

Series: GA6-1½, GA6-2, GA7-1¼, GA7-1½

AQUAVARTM 56 HYDROVIEW. Pumping System Controllers FILL VENT MAX. MAX. 3 4 NPT

GRUNDFOS PRODUCT GUIDE. Hydro Solo-E. Grundfos Hydro Solo-E booster sets 60 Hz

ITT. Goulds Pumps 70L, 90L, 150L, 200L, 300L Stainless Steel 6" Submersible Pumps. Engineered for life. Residential Water Systems. 60 Hz High Capacity

VERTICAL MULTI-STAGE PUMPS

Description 1/8-7.5HP

BOOSTER PUMPS PRODUCT FAMILY APPLICATIONS FAMILY COMPARISON CHART

J1000. Compact Inverter Series.

Series. NV Vertical Multistage Booster Pump

Series: GA6-1½, GA6-2, GA7-1¼, GA7-1½

Regenerative Turbine Pumps

OVIM/OVIMF. OVIM 60Hz OVIMF 60Hz. A New Vision for Quality Pumps. Light Vertical Multistage Centrifugal Pumps

OVIM/OVIMF. OVIM 60Hz OVIMF 60Hz. A New Vision for Quality Pumps. Light Vertical Multistage Centrifugal Pumps

HVAC Products. Introducing the SED2 Variable Frequency Drives

TW W-40 FLAG FRAME VARIABLE SPEED BOOSTER SYSTEM

Regenerative Turbine Pumps

Regenerative Turbine Pumps

Wilo CO-Helix Pressure Boosting Systems. Engineering Specification

3x3x7B Series 80 In-Line Mounted Centrifugal Pumps

franklinwater.com 50 Hz VR SERIES Vertical Multi-Stage Pumps

M50 L50 Series Multistage Regenerative Turbine Pumps

Design Envelope Booster Systems. Design Envelope Booster Systems. FILE NO: DATE: Feb. 05, 2010 SUPERSEDES: DATE: Jan.

VERTICAL MULTI-STAGE PUMPS

VSPS PACKAGE BOOSTER SYSTEM (END SUCTION PUMP DESIGN) FEATURES T Y P E

EZ SERIES BOOSTER PUMPS

Series

AQUAVAR AQUAVAR VARIABLE SPEED SYSTEM CONTROLLER. Applications. Specifications. Benefits of using Aquavar

MBN Multistage Ring Section Pumps

D51 D61 D71 D91 Series

ITT. Goulds Pumps 45J and 70J. Engineered for life B45-70J. Residential Water Systems. Features. 60 Hz High Capacity Flat Bowl 6" Submersible Pumps

J1000 D E F I 1000 J1000 J1000 J1000 J1000

TW W-40 FLAG FRAME VARIABLE SPEED BOOSTER PUMP SYSTEM

RS Series Multi-stage, Ring Section Pump For Pressures to 1,500 PSI

EZ SERIES BOOSTER PUMPS

ITT. Goulds Pumps 65L, 95L, 120L, 160L, 250L, 320L 6" Stainless Steel Submersible Pumps. Engineered for life B65-320L. Residential Water Systems

PumpSmart. Control Solutions

EZ SERIES BOOSTER PUMPS

INLINE 1100 COMPACT, MULTI-PUMP SYSTEM. franklinwater.com

EZ SERIES BOOSTER PUMPS

EZ SERIES BOOSTER PUMPS

Regenerative Turbine Pumps

Axial and Mixed Flow Pumps for Large Volume Pumping

EZ SERIES BOOSTER PUMPS

EZ SERIES BOOSTER PUMPS

INLINE 1100 STAGED PALLET SYSTEM. franklinwater.com

e-hm REPAIR PARTS REPAIR PARTS ReHM R1

20EVP-A SERIES. Vertical In-Line Self-Priming Centrifugal Pumps for Petroleums and Solvents. Marlow Pumps. Marlow Pumps.

Peerless Pump FULL PRODUCT LINE. Brochure B Sterling Fluid Systems (USA), Inc.

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

Series 50Hz Metric Edition

INLINE 1100 COMPACT, MULTI-PUMP SYSTEM

Series: CT. 4CT RPM - 60Hz. CT RPM - 60Hz. (See Indivdual curves for symbol number)

TECHNICAL BROCHURE B36/ /3742 CLOSE-COUPLED AND FRAME-MOUNTED CENTRIFUGAL PUMPS

Booster Pumps. Non-Submersible Pumps. BT4 Series. Cast Iron Features: Applications:

Hydropak Booster Systems. Series motralec

D Series. Centrifugal Pumps. Pump End Kits. Features: PAGE: CP-435 DATE: June 5, 2006

Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Dec. 15, Hydropak Booster Systems

The pumps shall be Oil Free and Variable speed controlled by Pressure Transducer, PLC and inverter.

Bulletin D51 September D51 D61 D71 D91 Series. Centrifugal Pumps. Capacities to 240 GPM Heads to 360 Feet MTH PUMPS

2CDU70/206-2HP 2CDU70/306-3HP CDU120/306-3HP 2CDU200/506-5HP 607

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

TECHNICAL BROCHURE B36/3742 R2 3642/3742 CLOSE-COUPLED AND FRAME-MOUNTED CENTRIFUGAL PUMPS

ILLUMINATOR LV. Emergency Lighting Inverter System 175VA through 750VA. Illuminator Series LV Single Phase

Series: EC & ED. EC & ED RPM - 60Hz. (See Indivdual curves for symbol number)

TW G-40 FLAG FRAME VARIABLE SPEED BOOSTER PUMP SYSTEM

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

LIFT INVERTER SERIES L1000V DE ES FR IT 1000V L1000V L1000V L1000V L1000V

2014 Auxiliary Catalog. Controllers Packages Systems Accessories. 37 Forestwood Dr., Romeoville, IL

Submersible Turbine Pumps

Six-Inch Submersible Pumps

Each pump shall be equipped with carbon/graphite vanes. A vacuum relief valve shall be incorporated into the design of the pump.

DuraMACTM Booster Pumps

Transcription:

ITT Commercial Water Goulds Pumps G&L Series Commercial Products Goulds Pumps is a brand of ITT Corporation. www.goulds.com Engineered for life

G&L Series Commercial Products Proven Performance Through The Power Of Experience. Goulds Pumps combines over 155 years of pump experience with the most modern design and manufacturing systems deep drawn metal fabrication, laser cutting, laser welding, precision casting, and worldwide design systems plus a total commitment to quality based on full performance testing of every pump we make. Whether you need stainless steel, bronze, or cast iron, multi-stage verticals or horizontals, end suction centrifugals or submersibles, there s a Goulds Pumps G&L Series Product design that s proven itself through years of dependable service. For booster service, liquid TABLE OF CONTENTS End Suction, Stainless Steel: NPE... 3 NPO... 3 MCS... 3 SSH... 5 ICS/ICS-F... 4 3657/3757... 4 LB... 4 End Suction, Cast Iron: 3642/3742... 4 MCC... 5 3656LH/3756LH... 5 3656/3756 S-Group... 6 3656/3756 M&L-Group... 6 Self Priming, Clear Liquids: Prime Line SP... 7 GT Irrigator... 8 PrimeLine... 8 2AUW, 3AUW... 9 High Pressure, Stainless Steel: SSV... 9 LC... 1 HMS... 1 transfer, spray systems, water circulation, dewatering, light chemical and industrial applications, there s a G&L Series pump that s done long time duty. Horizontal and vertical multi-stage capacities from 5 gpm to 35 gpm. Submersible capacities from 5 gpm to 5 gpm. And end suction centrifugal capacities from 4 gpm to 5 gpm. Goulds Pumps a brand offering the power of experience to more than 1 nations of the world. In addition to the standard pump designs shown here, we offer specialized O.E.M. pumps designed to meet the specifi cations of your particular needs. High Pressure, Cast Iron: GB... 1 HSC... 1 Vertically Immersed: NPV... 11 Multi-Stage: MPVN... 12 SMVT... 13 Variable Speed Control: Aquavar and Aquavar CPC... 14 AquaBoost... 14 Controls: Aquavar... 15 Aquavar CPC... 16 AquaBoost... 17 AquaBoost II... 18 Packaged Pump Systems: AquaForce... 19 2

A full range of end suction centrifugal pumps. Cast iron, bronze, investment cast 316 stainless steel and 34 stainless steel pump-end materials of construction. 1 x 1 1 4-5 through 8 x 1-13 sizes. Close coupled, frame mounted or engine drive confi guration. Capacities to 45 USGPM (1 m 3 /hr.). NPE 316L Stainless Steel Enclosed Impeller 5 4 3 2 1 16 14 12 1 8 6 4 2 1ST 175 RPM 1ST 1" x 1 1 4" 6 1 2 3 HP 35 RPM 2ST 175 RPM 2ST 1 1 4" x 1 1 2" 6 3 4 5 HP 35 RPM 3ST 175 RPM 3ST 1 1 2" x 2" 6 1 5 HP 35 RPM 2 4 6 8 1 12 14 16 U.S. GPM 5 1 15 2 25 3 35 m 3 /hr End Suction Heads to 5 ft. TDH (11 m). Working pressure to 25 PSI. Temperatures to 25º F. (12º C.). ANSI Flanged and NPT Connections. NPO 316L Stainless Steel Open Impeller m 35 3 25 FT 1 Model NPO Motors 1 & 3 phase. 5 or 6 hertz ODP, TEFC or explosion proof enclosures 35 & 175 RPM. Standard John Crane mechanical seals with high temperature and chemical duty options. 2 15 1 5 75 5 25 1"x1 1 /4" 6 1 /2 3 HP 1SN 1 1 /4"x1 1 /2" 6 1 5 HP 2SN 1 1 /2"x2" 6 3 7 1 /2 HP 35 RPM 3SN 5 15 2 25 US GPM 1 2 3 4 5 6 FLOW RATE m 3 h MCS 316L Stainless Steel Enclosed Impeller 5 16 4 14 12 H 3 2 1 8 6 1MS 1" x 1 1 4" 6 1 2 3 HP 35 RPM 2MS 1 1 4" x 1 1 2" 6 3 4 5 HP 35 RPM 3MS 1 1 2" x 2" 6 1 5 HP 35 RPM 1 4 2 2 4 6 8 1 12 14 16 U.S. GPM 5 1 15 2 25 3 35 m 3 /hr Q Stainless Steel 3

End Suction Stainless Steel 4 ICS/ICS-F Investment Cast 316 Stainless Steel Open Impeller (H) 3 2 1 125 1 75 5 25 1 x 1 1 4 5 175 RPM 1 SS ICS-F 1 x 1 1 4 5 35 RPM 1 SS 1 1 4 x 1 1 4 5 175 RPM 2 SS 1 1 4 x 1 1 2 5 35 RPM 2 SS 2 4 6 8 1 12 U.S. GPM 1 2 3 m 3 /h (Q) LB 34 Stainless Steel Enclosed Impeller (H) 5 4 3 2 1 PS I 8 7 6 5 4 3 2 1 FEE T 18 16 14 12 1 8 6 4 2 2 4 8 16 6 1 12 14 18 2 22 1. HP 5 NPSH 2% EFF 25% 1 3% ICS 1 2 3 4 5 (Q) 32% 2 33% 34% MODEL: LB SIZE: 1 x 1 1 4 RPM: 35 U.S. GPM m 3 /hr 3657/3757 Investment Cast 316 Stainless Steel Enclosed Impeller (H) 8 6 4 2 3 24 18 12 6 1 1 2 x 2 6 3 SS 1 1 2 x 2 8 5 SS 3657 2 x 3 7 4 SS 3757 35 RPM 1 2 3 4 5 U.S. GPM 2 4 8 1 12 m 3 /h (Q) 3642/3742 Cast Iron Enclosed Impeller, Iron, Bronze or Bronze Fitted, Cast Iron Pump 6 5 4 3 2 1 2 18 16 14 12 1 8 6 4 2 1 x 1 1 4-5 1 1 4 x 1 1 2-5 35 RPM 2 4 6 8 1 12 U.S. GPM 5 1 15 2 25 FLOW RATE m 3 /hr

SSH 316L Stainless Steel Enclosed Impeller 4 3 2 15 125 1 75 24SH 11ASH 5 1ASH 25SH 27SH 28SH 175 RPM End Suction 175 6 35 RPM 1 25 9ASH 4SH 7SH 8SH 5SH 6SH 22SH 23SH 15 125 1 75 5 25 5 4 3 2 1 24SH 11ASH 1ASH 7SH 9ASH 4SH 8SH 5SH 25SH 27SH 22SH 6SH 23SH 28SH 1 2 3 4 5 6 7 8 U.S. GPM 2 4 6 8 1 12 14 16 m 3 /hr 18 175 RPM 1 2 3 4 5 6 7 8 9 1 11 12 U.S. GPM 2 4 6 8 1 12 14 16 18 2 22 24 26 m 3 /hr 35 RPM MCC Enclosed Impeller Iron Casing Stainless-Fitted 3656LH/3756LH Enclosed Impeller Low Head, Bronze Fitted 5 16 6 4 14 5 12 H 3 2 1 1 8 6 4 2 1MC 1" x 1 1 4" 6 1 2 3 HP 35 RPM 2MC 1 1 4" x 1 1 2" 6 3 4 5 HP 35 RPM 3MC 1 1 2" x 2" 6 1 5 HP 35 RPM 2 4 6 8 1 12 14 16 18 2 22 U.S. GPM 5 1 15 2 25 3 35 4 45 5 m 3 /hr Q 4 3 2 2 x 2 5 35 RPM 2 1 2 x 2 1 2 5 35 RPM 3 x 3 5 35 RPM 4 x 4 5 175 RPM 4 x 4 5 35 RPM 1 5 x 5 6 175 RPM 3 x 3 5 175 RPM 2 x 2 5 175 RPM 2 2 x 2 1 2 5 175 RPM 1 2 3 4 5 6 7 8 9 1 5 x 5 6 35 RPM 5 Cast Iron

End Suction Cast Iron 6 3656/3756 S-Group Enclosed Impeller Iron, Bronze or Bronze Fitted Mechanical Seal or Packing 3656/3756 M & L-Group Enclosed Impeller Cast Iron or Bronze Fitted Mechanical Seal or Packing 3 25 2 15 1 5 8 6 4 2 3 24 18 12 6 1 x 2 8 1 x 2 7 1 1 2 x 2 6 1 1 2 x 2 6H 3 x 4 8 4 x 5 8 1 1 2 4 1 15 2 3 4 5 GALLONS PER MINUTE U.S. GPM 3656 Close Coupled 1 1 2 x 2 8 2 1 2 x 3 7 1 1 /2 x 2 1 2 1 /2 x 3 13 2 1 /2 x 3 1 2 1 /2 x 3 9 2 1 /2 x 3 8 3656 3756 4 x 6 16 3 x 4 13 3 x 4 1 35 RPM 1 2 3 4 5 U.S. GPM 6 GALLONS PER MINUTE 3 x 4 7 2 4 6 8 1 12 m3/hr 4 x 6 13 4 x 6 1 5 4 3 2 1 6 x 8 13 1 1 /2 x 2 1 1 175 RPM 8 x 1 13 8 6 4 2 2 1 /2 x 3 8 1x2 8 1x2 7 3756 SAE 2 1 /2 x 3 1 2 1 /2 x 3 9 1 1 2x2 8 3 x 4 8 3 x 4 1 2 4 6 8 1 GALLONS PER MINUTE 2 1 2x3 7 3756 4 x 5 8 175 RPM 1 1 2x2 6 / 1 1 2x2 6H 5 1 15 2 25 3 U.S. GPM 35 1 2 3 4 5 GALLONS PER MINUTE 3x4 7 6 7 m 3 /hr 8 35 RPM 12 14 16 18 U.S. GPM

General information on Self-Priming pumps. General water handling in applications where the liquid level is below the pump. Models are available with electric motor, or bearing frame depending on installation requirements. Prime Line SP Enclosed Impeller, Bronze Fitted Self Priming Ideal for irrigation, emergency cellar draining and farm water supply. 16 4 14 12 PRIME LINE SP 3 HP HIGH HEAD CURVE No. CN681R1 3 1 12 PRIME LINE SP 3 HP MEDIUM HEAD CURVE No. CN683R TDH 8 3 1 2 6 8 1 4 2 2 15 1 5 TDH 2 6 2 4 6 8 1 12 14 US GPM 4 5 1 15 2 25 3 m 3 /hr 1 2 25 2 15 1 5 2 4 6 8 1 12 14 16 18 2 US GPM 5 1 15 2 25 3 35 4 m 3 /hr 18 5 16 PRIME LINE SP 5 HP HIGH HEAD CURVE No. CN682R1 14 4 3 12 1 16 14 PRIME LINE SP 5 HP MEDIUM HEAD CURVE No. CN684R TDH 2 1 8 6 4 2 25 2 15 1 5 2 4 6 8 1 12 14 16 18 US GPM 1 2 3 4 m 3 /hr TDH 4 3 2 1 12 1 8 6 4 2 25 2 15 1 5 2 4 6 8 1 12 14 16 18 2 22 24 US GPM 5 1 15 2 25 3 35 4 45 5 m 3 /hr Clear Liquids 7

Self Priming Clear Liquids 8 GT Irrigator Enclosed Impeller Irrigation Duty (H) 4 3 2 1 12 1 8 6 4 2 25' 2' 25' 25' 25' 2' 15' 25' 2' 2' 1' 15' 15' 15' 1' 1' 1' 1' 5' GT1 5' 5' 5' 5' GT7 GT15 GT2 GT3 1 2 3 4 5 6 7 8 9 1 11 U.S. GPM 5 1 15 2 25 PrimeLine Self-Priming Centrifugal Pumps TOTAL HEAD IN 1 8 6 4 2 3 2 1 2P2 2P1 2P4 2P3 3P1 3P2 3P3 3P4 GALLONS PER MINUTE (Q) NEW PRIME LINE HYDRAULICS COVERAGE 4P1 & 4P2 1 2 3 4 5 6 7 8 IN U.S. GPM 2 4 6 8 1 12 14 16 18 IN CUBIC PER HOUR 2' TOTAL HEAD M 5 4 3 2 1 15' FT. 15 1 5 GPM m 3/h 4E1 m 3 /hr Frame-Mounted Only 6E2 6E1 5 1 15 2 1 2 3 4 5

2AUW, 3AUW Portable Contractor Pumps 12 2AUW HEAD TDH () 12 1 8 6 4 2 25 5 75 1 125 145 FLOW (GPM) High Pressure 1 8 HEAD TDH () 6 4 2 4 8 12 16 17 FLOW (GPM) 3AUW General information on high pressure multi-stage pumps. Stainless steel and cast iron pumps for pressure boosting in water supply, building trade, boiler feed, wash, fi ltration and general OEM applications. Stainless models are ideal for reverse osmosis and pure water systems. Flows to 65 GPM and heads to 11 feet. Excellent companions to the Aquavar for constant pressure systems. SSV Vertical Multi-Stage Pumps 14 35 RPM 35 175 RPM 4 12 35 3 1 25 8 2 6 15 4 1 2 4SV 5 46 3SV 66 92 1SV 2SV 33SV SV SV SV 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 GPM 1 2 4 6 8 1 15 2 3 4 6 8 1 14 m 3/h 1 5 25 3 25 2 15 1 5 1SV 2SV 3SV 4SV 33SV 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 GPM 1 2 4 6 8 1 15 2 3 4 6 8 1 14 m 3/h 46 SV 66 92 SV SV 9 Stainless Steel

High Pressure Cast Iron / Stainless Steel LC 34 Stainless Steel 1 7 6 5 4 3 2 1 EFF. % 2 15 1 5 5 4 3 2 1 5 3 16" DIA. (ALL MODELS) LCA EFF. LCA LCA NPSH LCB EFF. LCB NPSH 1 2 3 4 5 6 7 8 9 US GPM 5 1 15 2 m 3 /hr GB Cast Iron or 34 Stainless Steel PSI 25 15 1 5 2 15 1 5 1 5 4 3 2 5GB 7GB 1GB 18GB LCB MODEL LC CURVE CN466R 355 RPM LCC EFF. LCC NPSH RECOMMENDED RANGE 1 43 GPM 33GB 25GB 5 1 15 2 25 3 35 1 2 3 4 5 6 7 8 9 FLOW RATE 4 LCC NPSHr (ft) 25 2 15 1 5 MODEL: GB RPM: 35 BASED ON ZERO INLET PRESSURE CURVE NO. CN434R2 HMS 316L Stainless Steel 1 9 8 7 6 5 4 3 2 1 2 1 5 NPSHR 25 15 45 5 U.S. GPM 1 11 12 M 3 /Hr. 35 3 25 2 15 1 5 1HMS5 1HMS4 1HMS3 1HMS2 1HMS 1HMS 2HMS5 2HMS4 2HMS3 2HMS2 2HMS 2HMS 5 1 15 2 25 3 35 4 US GPM 1 2 3 4 5 6 7 8 9 m 3 /hr 1 HSC Cast Iron 24 7 22 6 5 4 3 2 1 2 HSC2 18 16 HSC15 14 HSC1 12 HSC7 1 8 6 4 2 NPSH R 6' 7' 12' 15' MODEL HMS SIZE: AS SHOWN RPM 35 CURVE: CF375R MODEL HSC SIZE 2 HP RPM 35 1 2 3 4 5 6 U.S. GPM 2 4 6 8 1 12 14 16 m 3 /hr 6 4 2 1 8 6 4 2 EFF. % NPSH (ft)

General information on Vertical Immersed pumps. 34 and 316 stainless steal pumps for machine tool, wash system and tank mount applications. Pump head is immersed in pumped liquid. May be set at various depths depending on tank. Single stage and high pressure multistage versions are available. NPV Vertically Immersed End-Suction Pump 5 16 Vertically Immersed (H) 4 3 2 1 14 12 1 8 6 4 1 x 1 1 4-6 1 2-2 HP 35 RPM 1SL 1 1 4 x 1 1 2-6 3 4-5 HP 35 RPM 2SL 1 1 2 x 2-6 1-5 HP 35 RPM 3SL 2 1SL 175 RPM 2SL 175 RPM 3SL 175 RPM 2 4 6 8 1 12 14 16 U.S. GPM 5 1 15 2 25 3 35 m 3 /hr (Q) 11

Vertical High Pressure Multi-Stage TOTAL HEAD H (ft.) TOTAL HEAD H (ft.) 12 Rugged vertical segmented ring construction. Available in all iron, stainless fi tted or all stainless for fl uid compatibility. Recommended for a wide variety of industrial, commercial, municipal and building trades pressure boosting applications. MPVN Vertical High Pressure Multi-Stage Pump Q [m3/h] 3 4 5 6 7 8 9 1 15 2 3 4 5 1 15 2 3 4 5 52 16 355 RPM 15 48 14 44 13 4.2 125.2 4 12 36 11 4.3 1.1 1 125.1 32 65.2 9 65.1 28 8 7 6 5 4 3 2 1 1.2 24 2 16 12 8 4 15 2 3 4 5 1 15 2 3 4 5 1 [I.G.P.M.] 15 2 3 4 5 1 15 2 3 4 5 1 [US.G.P.M.] Q 2 3 4 5 1 2 3 4 5 1 2 3 5 1 15 5 15 175 RPM 4 1 3 5 4 3 2 1 Q [m3/h] 4.2 4.3 65.1 65.2 1.1 125.1 1.2 125.2 1 15 2 3 4 5 1 2 5 1 1 15 2 3 4 5 1 2 5 1 Q 84P-24P Series Consult Factory 2 1 5 4 3 2 2 3 [I.G.P.M.] 2 3 [US.G.P.M.] H [m] H [m]

High effi ciency, High pressure design. Rugged cast iron/bronze construction. Available in bronze-fi tted or all stainless steel construction. Ideal for municipal and building trades water pressure boosting. Boiler feed version available. Turbine internals with in-line design. 3 25 1 9 8 SMVT Surface Mounted Vertical Turbine Vertical High Pressure 2 15 7 6 5 4 1SMA 2SMA 3SMA 1 5 3 2 4SMA 5SMA 6SMA 1 5 1 15 2 25 3 35 4 45 5 55 6 65 7 75 8 85 9 GPM 2 4 6 8 1 12 14 16 18 2 m 3 /hr 13 Multi-Stage

Variable Speed Control General information on Variable Speed Control systems. Aquavar pump control for constant pressure, constant fl ow, or system curve performance. Versions from 1 hp to 55 hp. Pump or wall mounted. Any three phase centrifugal pump motor (23/46 V). Eliminate large pressure tanks, separate control panels, by-pass lines, automatic valves, etc. Up to four pumps can be linked for automatic alternation. AquaBoost constant pressure system provides constant water pressure for homes and commercial properties. Automatically changes pump speed based on water demand. Complete with all needed components for installation. 1 to 3 HP available. Aquavar and Aquavar CPC Centrifugal Pump Controller, PLC and Variable Frequency Drive Adjustable to match system curve (ft.) Automatic pump shut off at zero consumption Up to 7% energy saving at partial load KILOWATTS 6 5 4 3 2 1 12 1 8 6 4 2 35 RPM PUMP CURVE 25% 5% 75% 1% 125% Automatic start of 2-4 pumps at peak demand Constant speed pump power requirement AQUAVAR (gpm) AquaBoost 14

Controls Power Supply 1x23 VAC L=L 1, N=L 2 Aquavar Pump Mounted Variable Speed Controller Up to 15 HP Pump Mounted Version AQUAVAR RS485 Interface Control Terminals Motor Connection 3 Phase Out U, V, W Available Configurations Horsepower Range Electrical Requirement 2 and 3 1 phase, 23 V 5, 7.5, 1, 15 3 phase,46 V Technical Data Single Phase Version: 2 and 3 HP Motor Rating: 3 phase, TEFC, 28 23 volt, 6 HZ, Class F insulation,nema design A or B Power Supply: single phase input, 22 24 volt, ±1%, 4 7 HZ Three Phase Version: 5 HP to 15 HP Motor requirements: 3 phase, TEFC, 46 volt, ±1%, 6 HZ, Class F insulation, NEMA design A or B Power Supply: 3 phase, 38 46 volt, ±1%, 4 7 HZ Pressure Transducer: 316 SS, 17-4 PH stainless steel, 1 4 NPT connection, shielded two wire cable, operating temperature 13º F to 25º F, supply voltage 7-35 Vdc, 4 2mA output. Accuracy is.5% of full scale, proof pressure is 4 x full scale. Display: Two line, 16 characters per line, LCD display. Easy to read pump language, pump on, system pressure, fault codes and system conditions are displayed. Motor Speed: variable between 7 HZ, or maximum RPM at 6 HZ depending on speed rating of standard AC induction motor. Ambient Temperatures (operating): 32 14º F ( 4º C), Humidity: 5% relative at 14º F (non-condensing) 9% relative at 68º F (non-condensing) Inverter design: IGBT, output frequency is a sinus valuated Pulse Width Modulated (PWM) Enclosure: NEMA 4, IP 55. Avoid excessive dust, corrosives or salts. Approvals: UL, cul, CE Protection: Over/Under voltage, motor overload, short circuit, ground fault, motor overheat (with thermistor), programmable no/low fl ow shut-down, low suction pressure, pump run-out. Control: Analog input control (4 2mA) two point control based on pressure, fl ow or differential pressure. Terminals: Dry relay contacts are available for pump run, pump error, low pressure switch, remote ON/OFF control, analog output 1 Vdc (system pressure) and full opened slave pump starter. Multi-Pumps: RS485 communication SIO (local only) up to four pumps. Alternate Input: Up to two transducers may be used with each controller. These may be pressure, fl ow, differential pressure, temperature or other 4 2mA signals. Aquavar Variable Speed Pump Controller The G&L Series AQUAVAR Pump controller is a combination of a variable frequency motor drive (VFD) and a programmable logic controller (PLC) in one compact package, which can be either mounted on the fan cover of the TEFC pump motor, or on a wall or panel near the pump. Each AQUAVAR controller is pre-programmed with patented pump specifi c software. Wall mounted units enable the AQUAVAR controllers to be used with either surface or submersible pumps. AQUAVAR controllers are specifi cally designed to work with all confi gurations of centrifugal pumps, so they will match pump output to a wide range of varying system conditions while protecting the pump, the motor and the pumping system. Variable Speed Control 15

Variable Speed Control Controls Introduction The G&L Series Aquavar CPC (Centrifugal Pump Controller) from Goulds Pumps incorporates the latest state-of-the-art Aquavar technology. The Aquavar CPC is a variable frequency drive and pump specifi c PLC in one compact unit, that will vary the speed of the motor to maintain a consistent pressure, fl ow, temperature or level. Here are just a few of the features and benefi ts of this innovative product: Start-up wizards expedite the programming process, for specifi c applications. Removable control panel/display. Fully backlit display with large text makes the control pad easy to read. Transducer assembly (-3 psi) included for constant pressure. Helps protect the pump from cavitation, dead head and blocked suction. Helps protect the motor from short circuit, phase loss, overload, undervoltage, overvoltage. Input choke reduces harmonics and provides 3-5% impedence line reactor. Built in! EMC/RFI fi lters reduces drive noise emissions and interference. Fieldbus compatible, standard Modbus Protocol (SCADA). Capable of controlling up to 3 fi xed speed pumps, with one drive. Multipump control for up to 4 pumps, without additional PLC s or control panels. Auto lead/lag and switching control built in. Ratings and Enclosures NEMA 1 (indoor use) standard other enclosures are available upon request. 1 15 HP (frame R1 R6) wall mounted. 2 55 HP (frame R7 and R8) fl oor mounted. Ambient temperature 5º F 14º F. Higher temperatures can be achieved using optional enclosure upgrades and derating factor for up to 122º F. At altitudes from to 33 feet rated current is available, for every 328 feet above 33 feet the current must be derated 1%. Maximum 66 feet (consult factory above 66 feet). Relative humidity lower than 95% without condensation. UL 58C compliant. UL, cul, CE approved. Electrical Characteristics Input Power 3 phase 38 V to 48 V +1%/-15% Frequency 48 to 63 Hz 1 phase 28 V to 24 V +1%/-15%.98 power factor 3 phase 28 V to 24 V +1%/-15% Output Power 3 phase from to Vsupply (All motors must be 3 phase.) to 6 Hz frequency 16 Aquavar CPC Wall Mounted Version

AquaBoost Variable Speed Constant Pressure Systems Product Overview The AquaBoost pump controller and complete booster package kits provide an economical answer for municipal water district customers with low water pressure. Both domestic and light commercial applications can benefi t. As water use increases, the AquaBoost changes pump speed to keep line pressure constant. Large supply tanks are eliminated and up to 5% of the energy required by a full speed pump is saved. The AquaBoost is available with a range of fl ow rates to handle homes with up to four baths, irrigation systems, fi ltration and fi re suppression systems. The AquaBoost is available as either a separate controller or as part of a complete pump package with everything you need to plumb it to a domestic water line. Components 1AB1HM1E2D 4.8 Amp AquaBoost controller, wall mount set, HMS stainless steel pump, transducer, V6P tank, pressure gauge, discharge tee. Controller is pre-wired and pre-programmed. Flows to 2 GPM. Variable Speed Control 1AB2HM1E2D 4.8 Amp AquaBoost controller, wall mount set, HMS stainless steel pump, transducer, V6P tank, pressure gauge, discharge tee. Controller is pre-wired and pre-programmed. Flows to 37 GPM. 1AB1 4.8 Amp AquaBoost controller, wall mount set, transducer, pre-wired, pre-programmed. (Pump and tank not included.) + The AquaBoost Advantage + Pressure Pressure Flow + Typical home water pressure drops when demand is high. Flow + The AquaBoost makes up the pressure difference at peak demand for constant home water pressure. 17 Controls

Variable Speed Control Controls AquaBoost Controller Features Input Power* 2-23V ±15%, single phase (controller only) Output Power Up to 23V three phase (based on input voltage). Motor rated for 28-23V, ±1%. Maximum Output Current 4.2 amps 1AB2; 6.9 amps 2AB2 Input Controls Up and down buttons to turn unit on and off and set pressure. Signal Lights Power on, pump running, inverter stopped, pump stopped, standby, faults/errors. Electrical Effi ciency Over 95% Protection Against Short circuit, under voltage, overload, motor temperature, dead heading, run out, suction loss, sensor fault, bound pump, over voltage, static discharge. Note: Suction loss/run out is set for minimum 1 psi at discharge! Ambient Temperature 34º F to 14º F Maximum Humidity 95% at 14º F, non-condensing Air Pollution Avoid mounting in areas with excessive dust, acids, corrosives and salts. Approvals Controller Enclosure NEMA 3R, IP 43 (Rain-tight) Mounting Wall mount with mounting hardware. Cooling Convection with heat sink. Transducer.5-4.5 VDC with 5 VDC power supply, 1 psi range, 8-inch 3-core cable. Input Wire 5 feet of 14 gauge cable. Cable is pre-wired to controller and junction box. Output Wire 1 feet of 14 gauge cable. Cable is pre-wired to controller and pump motor (when provided). *Low input voltage may affect motor operation. Pressure Range Nominal Range Field adjustable from 2-85 psi, total system pressure. WARNING C U L US DO NOT SET REQUIRED SYSTEM PRESSURE ABOVE 85 PSI. SEVERE DAMAGE TO PLUMBING COULD RESULT. AquaBoost II Variable Speed Constant Pressure Systems (8.38).33 (242.4) 9.53 (99.6) 3.9 (232.56) 9.16 (157.9) 6.22 (57.15) 2.25 (114.3) 4.5 (81.28) 3.2 1AB2 (16.51).65 (259.8) 1.2 (12.7).48 (237.6) 9.33 1 2 Liquid Tight (135.36) 5.33 18

Features and Specifications All systems are UL rated. Maximum footprint, on most sizes, allow systems to fi t through standard doorways. 2 23 Volt single phase 1 1 HP, 2 23 Volt three phase 1 2 HP, 46 Volt 1 3 HP. Each system is fabricated with G & L stainless steel or cast iron centrifugal pumps with a variety of electrical and mechanical options to choose from. Standard off the shelf motors by Baldor or USEM Motors. Signifi cant reduction in energy consumption over fi xed speed systems. System protection from overvoltage, under-voltage, blocked suction, cavitation, NPSHa, phase loss, short circuit, transducer failure, and motor overload. Liquid temperatures up to 212º F. Ambient temperatures up to 14º F. Maximum operating pressures up to 36 psi. Pump run-out protection. Dry running protection. AquaForce Engineered Pump Stations Engineered Pump Stations Programmable lead/ lag alternation. Programmable system curve/ friction loss compensation. Programmable system pressure starting. Fault detection and alarms relay. Motor run relay. Programmable soft start. Stainless steel or optional carbon steel piping. Isolation valves. Optional suction / low pressure switch. Optional pressure relief valves and temperature relief valves. Optional lightning protection. Optional fl exible discharge hose. 19 Packaged Pump Systems

ITT Commercial Water Distributor Information Goulds Pumps, G&L, Aquavar, AquaBoost, AquaForce, CentriGuard, GT Irri-Gator, PrimeLine, CentriPro and the ITT Engineered Blocks Symbol are registered trademarks and tradenames of ITT Corporation. Modbus Protocol is a registered trademark of Modicon Inc. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. BRGLCAR2 April, 27 27 ITT Corporation Engineered for life 2