CABINET - INSTRUMENT TRANSFORMER Indoor - Outdoor, 480 Volt Maximum 1200, 1600, 2000 Ampere

Similar documents
CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum

ENTRANCE EQUIPMENT ER D PAGE 1 OF 5

COMMERCIAL QUICK REFERENCE

AMENDMENT ELECTRIC SERVICE MANUAL 2014

Current Transformer, Termination & Disconnect Cabinets WE Energies Approved

MARWELL CORPORATION Manufacturer of UL Listed Meter Socket Adapters

10 Commercial, Industrial, Agricultural Services

Section 6 Electric Metering: Residential

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp

New York City Apartment Metering Meter Sockets / Load Centers

ELECTRICAL METERING RESIDENTIAL

CT Metering. CT Metering. Meter Mounting Equipment

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

SECTION PANELBOARDS

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Metering and Service Installation:

UNDERGROUND SERVICE ENTRANCE LOCATION. No meter base or entrance should be installed before an KREMC engineer has checked the proposed location.

Approved Meter Sockets and Cabinets

Meter Installation. -and- Padmount Transformer Guide

METERING REQUIREMENTS

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim

UNDERGROUND SERVICE ENTRANCE LOCATION. No meter base or entrance should be installed before an KREMC engineer has checked the proposed location.

GE 8000-Line Motor Control Centers

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Horsepower Ratings 240V AC 1 Phase, 2 Phase, 3 Phase, Ampere Catalog List Ship Wt.* Catalog List Ship Wt.* Indoor Type 1 Outdoor Type 3R

FACT SHEET Standard: Electrical Safety

CON EDISON EQUIPMENT

Group Meter Main - Without Bypass

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

SECTION VII METERING INSTALLATIONS

Lighting and Power Distribution Panelboards

DISCONNECT SWITCH REQUIREMENTS FOR DISTRIBUTED GENERATION CUSTOMERS

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

10. METERING General Requirements

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified.

fastfax Rock Solid TM Load Centers General Information

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

Product Guide. NEMA pump controls.

Recreational Vehicle Park Electrical Products & Accessories

A. Submit manufacturer's literature and technical data before starting work.

Electric & Gas Service Requirements (Greenbook) Overview

Three-Phase Pole Mounted Recloser

PEU reserves the right to determine all meter locations. Only authorized PEU personnel will determine this location.

Design Standard. Purpose: Design Standard:

OVERHEAD SERVICE. Items to consider

C1000 Series Automatic Cap Bank

TABLE OF CONTENTS. Important Notices Underground Plant Protection Information. Commercial/Industrial Information Sheet

15-kV Live Terminal 600 Amp Group Operated Pad-Mounted Metal-Enclosed Outdoor Switchgear 140 Amp (Max) Clip Mount Current-Limiting Fuses

Product Specifications for Aluminum Vertical Break Switches

Accessories. Accessories. Meter Mounting Equipment

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

Quick Connection Panel (QCP) Installation Guide

Modular Metering. Canadian Version

15-kV Safefront 200 Amp Primary Capacitor Station Pad-Mounted Outdoor

Meter Mains - Without Bypass

Midwest Electric Products. Safety Switches Rugged, reliable and easy to install

Engineering Service Specifications. Commercial Single-Phase Current Transformer Metering Schemes

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

Underwriters Laboratories Inc. Marking Guide. Panelboards. July 2004

AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS

WPS SERVICE MANUAL. Section Amp and Larger - Common

UNDERGROUND SERVICES - SECONDARY

WPS SERVICE MANUAL. Section Amp and Smaller - Common

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch

Clark Public Utilities Commercial Electric Service Handbook. This page left blank intentionally.

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625

QMB Panel boards Switchboards. 200,000A. short circuit rating. www. ElectricalPartManuals. com

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles

Specification Number: Product Name: GROUP MOUNTED MAIN FUSIBLE SWITCH, GROUP MOUNTED BRANCH FUSIBLE SWITCH (LONG) SECTION

Heavy Duty Safety Switches

9200 Revenue Meter. Model Certification Current Inputs. Complies with the accuracy requirements of the ANSI C Revenue Metering Standard

Customer Requirements Downtown Secondary Network Service

35-kV Safefront 200 Amp Primary Metering Station Pad-Mounted Outdoor

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

Product Specifications for Phase Over Phase GOABS(r)

Approved Contractor Construction e-guide Residential Commercial

Panelboards and Lighting Control. Types PRL1a, 2a, 3a, 3E, 4 and Column Modifications. Contents Description

Indianapolis Power & Light Company

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

CIRCUIT BREAKER PANELBOARDS

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

35-kV Thru-Bushings F Series (bolt-in) for Air-Insulated to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING

PlexPower Fused Factory Sealed Panelboard with Bus Bar Up to 30 Amps. Stainless Steel Enclosures

SERVICE REQUIREMENTS COMMERCIAL & INDUSTRIAL CUSTOMERS

Dry-Type Transformers Mini-Power Centers

Customer Requirements Meter Socket Configurations

Electric Service Requirements

7. SERVICES OVER 600 VOLTS


XP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System

Requirements for Secondary Voltage Revenue Metering (750 V and less)

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

Transcription:

Printed from NIPSCO.com 04-01-17 PAGE 1 OF 6 USE: 1. For commercial and industrial installation, purchased and installed by the customer. 2. To enclose 600 volt insulation class instrument transformers on indoor or outdoor meter installations. 3. For installing 2 or 3 each of current and voltage transformers. 4. For use on the following services: 120/240 volt 1 phase 3 wire, 240 volt 3 phase 3 wire, 120/208 volt 3 phase 4 wire, 480 volt 3 phase 3 wire, 277/480 volt 3 phase 4 wire, 2,000 ampere maximum. LATEST REVISION: PREVIOUS REVISION 10-01-16 ORIGINATED 03-94 PREVIOUS NUMBER E 15-460-C, 03-29-90 Updated s with Milbank which recently purchased the Galva-Closure Products Co. C.T. Cabinet line. Milbank UG cabinets not UL approved at this time. SPECIFICATION: 1. GENERAL: 1.1 All current carrying parts should be designed on the basis of 1,000 amperes per square inch cross sectional area for copper and 700 amperes per square inch cross sectional area for aluminum. 1.2 Spacing between opposite polarity live parts and between live parts and ground mounted on the same surface, shall be a minimum of 2 inches and 1 inch, respectively, in accordance with the National Electric Code, latest revision, 408.56. 1.3 The cabinet shall have a hinged door with a sealing device so constructed that one padlock seal will effectively prevent opening the door. The cabinet shall be a minimum of 36" wide and high enough to provide adequate space for line and load side conductors. 1.4 Mounting provisions for voltage transformers used in 480 volt or 277/480 volt circuits are to be as follows: 1.4.1 Mounting provisions are to be located inside the instrument transformer cabinet in such a manner that adequate space is available for current transformers and service conductors. 1.4.2 An attached sealable side gutter (mounted on the right side of the cabinet) is to be used in lieu of mounting the voltage transformers inside the instrument cabinet when space limitations are a factor. Space limitations exist on services in which the total numbers of line and load conductors exceed 24 or when larger conductors such as 500 MCM copper or 750 MCM aluminum are used. 1.5 Cabinets shall be marked by the manufacturer with the voltage, current rating, and number of phases for which they are designed and with the manufacturer s name or trademark so as to be visible after installation, without disturbing interior parts or wiring, in accordance with National Electric Code, 408.58, latest revision.

04-01-17 PAGE 2 OF 6 Printed from NIPSCO.com 1.6 Voltage Transformer Gutter 1.6.1 The gutter shall be made of the same material and have the same thickness as the main cabinet. 1.6.2 The cover of the gutter shall be adequately secured by screws and shall be sealable. 1.6.3 Conduit connections are not to be made on this gutter assembly. 2. SPECIFICATIONS FOR INDOOR / OUTDOOR CABINET: 2.1 NIPSCO shall provide the bar type current transformers for the cabinet. 2.2 Connections shall be as follows: Line Connections shall be made on the top connection plate, and Load Connections shall be made on the bottom connection plate. 2.3 service installations require a side wiring gutter and shall be mounted to the left side of the cabinet.

Printed from NIPSCO.com 04-01-17 PAGE 3 OF 6 3. ADDITIONAL REQUIREMENTS FOR OUTDOOR CABINETS: 3.1 All hardware shall be rust resistant. 3.2 The door or front cover shall be made rain-tight and top shall be protected with a rain shield. 3.3 Rain tight screened vent kit shall be located in the upper side of the cabinet. 3.4 All conduit shall enter the cabinet through the sides or bottom; or, through the rain tight hub on the top.

04-01-17 PAGE 4 OF 6 Printed from NIPSCO.com 4. APPROVED MANUFACTURERS FOR INDOOR / OUTDOOR CABINET: 4.1 120/240 Volt, 1 Phase, 3 Wire: Two (2) Current Transformers Required. 1200 AMP CT 121-NI CT 121-NI-SG 1600 AMP CT 161-NI CT 161-NI-SG 2000 AMP CT 201-NI CT 201-NI-SG 1200 AMP NIP-1213 1600 AMP NIP-1613 2000 AMP NIP-2013 4.2 240 Volt, 3 Phase, 3 Wire: 4.2.1 Omit neutral connection plate. 4.2.2 Two (2) current transformers required-provide copper link for B phase. 4.2.3 Two (2) voltage transformers required only for phase shifting transformers when reactive metering is required. 1200 AMP CT 123-NI CT 123-NI-SG 1600 AMP CT 163-NI CT 163-NI-SG 2000 AMP CT 203-NI CT 203-NI-SG 1200 AMP NIP-1233 1600 AMP NIP-1633 2000 AMP NIP-2033

Printed from NIPSCO.com 04-01-17 PAGE 5 OF 6 4.3 120/208, 3 Phase, 4 Wire: Three (3) current transformers required. 1200 AMP CT 124-NI CT 124-NI-SG 1600 AMP CT 164-NI CT 164-NI-SG 2000 AMP CT 204-NI CT 204-NI-SG 1200 AMP NIP-1234 1600 AMP NIP-1634 2000 AMP NIP-2034 4.4 480 Volt, 3 Phase, 3 Wire: 4.4.1 Omit neutral connection plate. 4.4.2 Two (2) current transformers required-provided copper link for B phase. 4.4.3 Two (2) voltage transformers required-mounting provisions to be located inside the instrument transformer cabinet in such a manner that adequate space is available for current transformers and service conductors. An attached sealable side gutter is to be provided with the instrument transformer cabinet for the mounting of the voltage transformers if space limitations do not allow mounting PT's inside the instrument transformer cabinet. 1200 AMP CT 123-PT-NI CT 123-PT-NI-SG 1600 AMP CT 163-PT-NI CT 163-PT-NI-SG 2000 AMP CT 203-PT-NI CT 203-PT-NI-SG 1200 AMP NIP-1263 1600 AMP NIP-1663 2000 AMP NIP-2063

04-01-17 PAGE 6 OF 6 Printed from NIPSCO.com 4.5 277/480 Volt, 3 Phase, 4 Wire: 4.5.1 Three (3) current transformers required. 4.5.2 Three (3) voltage transformers required-mounting provisions to be located inside the instrument transformer cabinet in such a manner that adequate space is available for current transformers and service conductors. An attached sealable side gutter is to be provided with the instrument transformer cabinet for the mounting of voltage transformers if space limitations do not allow mounting the PT's inside the instrument transformer cabinet. 1200 AMP CT 124-PT-NI CT 124-PT-NI-SG 1600 AMP CT 164-PT-NI CT 164-PT-NI-SG 2000 AMP CT 204-PT-NI CT 204-PT-NI-SG 1200 AMP NIP-1264 1600 AMP NIP-1664 2000 AMP NIP-2064