DIESEL GENERATOR SET MTU 10V1600 DS500

Similar documents
DIESEL GENERATOR SET DG00660D5

DIESEL GENERATOR SET MTU 12V1600 DS660

DIESEL GENERATOR SET MTU 4R0113 DS80

DIESEL GENERATOR SET MTU 16V2000 DS1000

DIESEL GENERATOR SET MTU 20V4000 DS2650

DIESEL GENERATOR SET MTU 16V2000 DS KVA

DIESEL GENERATOR SET MTU 12V4000 DS1650

DIESEL GENERATOR SET MTU 18V2000 DS1400

DIESEL GENERATOR SET MTU 12V4000 DS2000

DIESEL GENERATOR SET DP03000D5S

DIESEL GENERATOR SET DP01800D5S

DIESEL GENERATOR SET MTU 20V4000 DS3300

DIESEL GENERATOR SET MTU 20V4000 DS3100

DIESEL GENERATOR SET MTU 16V2000 DS1100

DIESEL GENERATOR SET MTU 12V4000 DS1650

DIESEL GENERATOR SET MTU 16V4000 DS2250

DIESEL GENERATOR SET MTU 16V4000 DS2500

DIESEL GENERATOR SET DS01650D5S

DIESEL GENERATOR SET MTU 16V4000 DS2250

DIESEL GENERATOR SET MTU 12V4000 DS2250

DIESEL GENERATOR SET MTU 20V4000 DS3250

DIESEL GENERATOR SET MTU 16V4000 DS2500

DIESEL GENERATOR SET DS03200D5S

DIESEL GENERATOR SET MTU 16V4000 DS2500

DIESEL GENERATOR SET MTU 12V4000 DS1750

DIESEL GENERATOR SET MTU 20V4000 DS3600

DIESEL GENERATOR SET MTU 20V4000 DS4000

DIESEL GENERATOR SET MTU 16V4000 DS2250

POWER MODULE MTU 16V4000 DS2560

KVA KW KVA KW

KVA KW KVA KW

KVA KW KVA KW

20' STANDARD CONTAINER MTU 16V2000 DS: kva MTU 18V2000 DS: kva

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 415 Volts

HDW-200 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by DOOSAN

CMEC POWER GENERATION. PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET WHERE THE WORLD TURNS FOR POWER FEATURES

Bore mm 4.35 in Displacement 8.8 L 535 in³ Stroke mm 4.5 in Compression Ratio 10.1:1

3412C Generator Set Electric Power. Specifications. Benefits and Features

Voltage 220 to or 1800 RPM

HFW-350 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 415 Volts

CUMMINS 30KVA. Voltage kva kw kva kw Amp 400/230 30,00 24,00 27,00 21,60 38,00

for Power Generation Continuous/Prime/Peak Applications with air-to-air charge air cooling

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 400 Volts

220 to Volts or 1800 RPM

220 to Volts or 1800 RPM

Generating Rates WATER-COOLED THREE PHASE 50 HZ DIESEL. ADVANCED with quality certification ISO 9001

DIESEL GENSET. Prime Hz 16 kw / 20 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Bore mm 4.0 in Displacement 5.7 L 350 in³ Stroke 88.4 mm 3.48 in Compression Ratio 9.4:1

220 to Volts. Generator Set Configurations U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva. Prime Ratings kw/kva 240MONO / 10 9 / 9

YOUR POWER PARTNER. Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw 400/ ,

Specifications. 3406C Generator Set Electric Power

Voltage kva kw kva kw Amp 400/ ,00 88,00 100,00 80,00 144,00

TM20UCM MODEL. Standard Features. Generator Ratings. Conditions of sale. Prime Hz 18 kw / 18 kva. General features :

Generator Set Specifications 100 ekw (125 kva)

Model NA 2 L

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00

Voltage kva kw kva kw Amp 400/ ,00 160,00 180,00 144,00 259,00

PRIME 591 ekw 739 kva 60 Hz 1800 rpm 480 Volts

STANDBY 200 ekw 250 kva

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

PGDLS352KW 380/ / / / / / / / /

Engine Specifications 3512C HD ATAAC, V-12, 4-Stroke Water-Cooled Diesel Compression Ratio 14.7:1 Aspiration

Prime Hz 400 kw / 500 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 415 Volts

STANDBY 200 ekw 250 kva

PGDLS / / / / / / / / /

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized

TECHNICAL SPECIFICATIONS FOR 380/410 KVA, 6 CYLINDER DIESEL GENERATOR SET PACKAGED BY SCOPE OF SUPPLY FOR DIESEL GENERATING SET PACKAGE

SIVASA Doosan Series. SD250 Technical Data

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

PGDLS200. Overall Dimensions (mm) & Weight (kg) Length:3900. Width:1140. Height: 1850

PRIME. 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

Continuous, Prime, Standby, Mission Critical

PGCLS Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

220 to volts. Electronic unit injection

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

CONTINUOUS 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

DIESEL GENSET. Prime 60Hz 36 kw / 45 kva

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

60 Hz FEATURES. Exclusively from your Caterpillar dealer

STANDBY 80 ekw 100 kva PRIME 72 ekw 90 kva

Generator Set Configurations Low Fuel Consumption, EU Stage IIIA Nonroad Emission Standards, China Nonroad III Emission Standards

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ ,00 880, ,00 824, ,00

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Transcription:

DIESEL GENERATOR SET MTU 10V1600 DS500 400 230 V/460 kva/50 Hz/Prime Power Series 1600 MTU 10V1600 Optional equipment and finishing shown. Standard may vary. PRODUCT HIGHLIGHTS // Benefits - Industry-leading average load factor - Low fuel consumption - Emissions optimizations available - High availability and reliability - Outstanding load acceptance - Long maintenance intervals // Support - Global product support offered // Standards - Engine-generator set is designed and manufactured in facilities certifi ed to standards ISO 2008:9001 - Generator set complies to ISO 8528 and fullfi lls performance level G3 - Generator meets BS5000; NEMA MG 1; ISO; DIN EN and IEC standards - NFPA 110 // Wide Standard Scope of Supply - 4P circuit breaker - Island operation control panel - Integrated fuel tank - Industrial silencer (15 db(a)) - Batteries & battery charger // Complete range of accessories available - Sound attenuated enclosure - Fuel system accessories - Control panel & ATS - Range of additional electronical options // Warranty - Standard 36 months warranty after shipment // Available optimizations - TA-Luft (NOx < 1500mg/m 3 i.n.) optimized - Exhaust emission EU 97/68 EC Stage III A - NEA Singapore for off road diesel engines (ORDE) - ARAI CPCB Stage II - Fuel optimized

2 / / / MTU 10V1600 DS500 / 50 Hz / 400-230V APPLICATION DATA ➀ // Engine Manufacturer MTU Model 10V1600G10F Type 4-cycle Arrangement 10-V Displacement: L 17.5 Bore: mm 122 Stroke: mm 150 Compression ratio 17.5 Rated rpm 1500 Engine governor ECU 8 Gross power: kwm 407 Air cleaner Dry // Fuel System Max. fuel flow: L/h 342 Fuel tank capacity: OPU (EPU) in L 740 (740) Autonomy: h 9 // Fuel Consumption L/h At 100% of power rating: 101.75 At 75% of power rating: 80.22 At 50% of power rating: 55.37 // Liquid Capacity Total oil system: L 60.5 Total coolant capacity: L 94 // Generator Generator brand Generator type Insulation class Bearing Enclosure Voltage regulation Exciting system // Electrical Mecc-Alte HM355A3 H-class single bearing IP23 M A.V.R. (electronic) self-excited, brushless Electric system volts DC 24 Number of batteries 2 Capacity: Ah 2x 75 // Air Requirements Aspirating: m 3 /min 24 Cooling air flow: m 3 /s 10.9 // Exhaust System Gas temp. (stack): C 549 Gas volume at stack temp.: m 3 /min 68.4 Maximum allowable back pressure: kpa 15 // Cooling/Radiator System Ambient capacity of radiator in OPU (EPU): C 50 (50) Pressure on rad. exhaust: kpa 0.2 Heat rejection to coolant: kw 216 ➀ Technical data is for a fuel-optimized unit.

3 / / / MTU 10V1600 DS500 / 50 Hz / 400-230V STANDARD AND OPTIONAL FEATURES // System Ratings (kw/kva) MTU 10V1600 DS500 Prime operation Voltage 400 V Phase Three phase Hz 50 kwel* 367.2 kva** 459 Rated AMPS 662.5 * cos phi = 1,0 ** cos phi = 0,8 Also available for following voltages 380V & 415V - for details please contact your local MTU Onsite Energy Dealer. // Engine 4- strokes diesel engine Flywheel housing SAE 1 Flywheel 14'' Four-valve, overhead camshaft Piston cooling via oil spray nozzle Forged crankshaft & connecting rods Oil pan Lube oil circulation pump Dry exhaust manifolds Hot components and radiator guards Mobile components guards Lube oil filter // Fuel system Fuel main filter Fuel pre-filter with water seperator Common rail fuel injection Integrated fuel tank (level sensor and drain cap incl.) Automatic fuel transfer pump Heavy-duty fuel pre-filter with water seperator 3-way valve for fuel filling Fuel cooler // Generator 3-Phase, syncronos, brushless, self exciting, self regulating, self ventilating alternator Winding temperature sensors IP23 M protection degree IP23 protection cover Bearing temperature sensors Insulation class H Anti condensation heater Permanent magnet // Control Panel & Electric Options Control and power electric panel, with measurements devices and contoller ATS (Automatic Transfer Switch) Control version for parallel operation Control version for synchronizing a single genset with mains Programmable timer for MM7 and MC7 Remote display Expansion module for CAN communication Change over power supply for MC7 Input Output/LED expansion modules for DeepSea controllers ModBus connection to customer systems TCP/IP Control version for synchronizing with mains without blackout Converter kits CAN to RS485/USB/LAN Represents standard features Represents optional features

4 / / / MTU 10V1600 DS500 / 50 Hz / 400-230V STANDARD AND OPTIONAL FEATURES, CONTINUATION // Circuit Breaker/Power Distribution 4 poles manual circuit breaker (motorized with DeepSea controllers) // Starting/Charging System 24V electric system Starting batteries installed Pre-heating resistance/jacket water heater Battery charging alternator Battery disconnector Battery charger // Air Intake System Exhaust turbochargers Set of dry-type air filters with contaiment indicator Intercooler, integrated in radiator Heavy duty air filter with automatic dust evacuation // Exhaust System Industrial silencer 15 db(a) Residential silencer 35 db(a) Exhaust bellows // Cooling System Coolant circulation pump Front type radiator for jacket water and charge aircooling circut with integrated expansion tank Engine mounted fan drive // Mounting System Mounted on steel base frame Resilent mounting of engine and generator // Enclosures Sound proof enclosure Socket box Increased fuel tank capacity // Documentation & Certifications Genset & component manuals Maintaince schedule CE-certification for EU Fluids and lubricants specification Represents standard features Represents optional features

5 / / / MTU 10V1600 DS500 / 50 Hz / 400-230V WEIGHTS AND DIMENSIONS Drawing above for illustration purposes only, based on standard open and enclosed power 400 Volt engine-generator set. Lengths may vary with other voltages. Do not use for installation design. See website for unit specific template drawings. System Dimensions (L x W x H) Weight (wet/with standard accessories) Open Power Unit (OPU) 3.600 x 1.604 x 2.121 mm 3.872 kg Enclosed Power Unit 4.500 x 1.800 x 2.340 mm 5.582 kg Consult the factory for accurate weights and dimensions for your specific engine-generator set. Lengths may vary with other voltages. Do not use for installation design. SOUND DATA Unit Type Open Power Unit: db(a) on request Enclosed Power Unit: db(a) 63.5 Sound data is provided at 7m for 75% prime power. RATING DEFINITIONS AND CONDITIONS // Prime power ratings apply to installations where utility power is unavailable or unreliable. At varying load, the number of generator set operating hours is unlimited. A 10% overload capacity is available for one hour in twelve. Ratings are in accordance with ISO 8528-1, ISO 3046-1, BS 5514, AS 2789 and DIN 6271. Average load factor: < 75%. // Derating factor: Altitude: Consult your local MTU Onsite Energy Power Generation distributor for altitude deratings. Temperature: Consult your local MTU Onsite Energy Power Generation distributor for temperature deratings. Rated power for reference conditions at 25 C and 100m above sea level. Subject to change. 3237931 Edition 02/14 ENC 2014-08. Materials and specifications subject to change without notice. MTU Onsite Energy A Rolls-Royce Power Systems Brand www.mtuonsiteenergy.com