Copper Vertical Break Switch kv A.

Similar documents
Aluminum Vertical Break Switch kv A.

Operators/Accessories. Type V2-CA Aluminum. Vertical Break Switch. Ordering Information Furnish: Available Accessories. Standard Operator Features

Aluminum Vertical Break Switch 345 kv, 1300 kv BIL 2000 A A.

Copper Double Break Switch

CLEAVELAND / PRICE INC. Type RL-C Side Break Switch kv A. Bulletin DB-104E12

TYPE V CENTER BREAK SWITCH

Product Specifications for Aluminum Vertical Break Switches

TYPE EE and EEB CENTER- SIDE-BREAK SWITCH TYPE VEE and CBV CENTER BREAK V SWITCH 1200, 1600, 2000 & 3000 Amperes 7.

Type EB, EBB, EBF and VEB DOUBLE SIDE BREAK SWITCHES 38 kv through 362 kv 600 to 3000 Ampere

AIRBREAK SWITCHES East Ginter Rd. Tucson, Arizona USA (520) Fax (520)

Disconnect & ByPass Switches

M-Force three-phase switch

CENTER BREAK GROUP OPERATED AIR BREAK SWITCHES RATED 15.5kV THROUGH 170kV EFFECTIVE DATE: 10/25/16 REV B

SPECIFICATION BULLETIN

Transmission Switching

Unitized Quick Install Switches for Transmission Applications

3.0OVERHEAD TRANSMISSION SWITCHES

M-Force three-phase switch

Horizontal Circuit Switchers

Horizontal Circuit Switchers

Product Specifications for Phase Over Phase GOABS(r)

Catalog 14A January 2013

S&C Recloser Bypass Disconnects

Transmission Switching

OVERHEAD DISTRIBUTION SWITCHES

Typical Specification

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

S&C Alduti-Rupter Switches. Outdoor Distribution, 14.4 kv through 69 kv

Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

TYPE BLT DISCONNECT SWITCHES

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

S&C Loadbuster Disconnect Switches. Outdoor Distribution (14.4 kv through 34.5 kv)

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv)

S&C Manual PME Pad-Mounted Gear

Specifications. S&C Alduti-Rupter Switches with Power Fuses Outdoor Distribution (14.4 kv through 46 kv)

Unitized Quick Install Switches for Substation Applications

IB-FAS3 Mar Type FAS THRU 115Kv Amp 61 KA Momentary. Vertical-Break, Gang-Operated Outdoor Air Disconnect Switch.

S&C TripSaver II. Cutout-Mounted Recloser. For enhanced lateral circuit protection at 15 kv and 25 kv

S&C Loadbuster Disconnects

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc

INSTRUCTIONS. S&c Circuit-Switchers - Mark v Grounding Switches - 70,000 Amperes Momentary Outdoor Transmission I INTRODUCTION INSTRUCTION SHEET 7 1 1

Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Medium Voltage Metal-Enclosed Switches

Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance

PATENT PENDING. Phone: (877) Operation and Service Manual

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

Publication No.: PSG

Horizontal center break disconnector Type SDF, up to 550 kv Maximum reliability and minimal maintenance

SIEMENS. Series 8100oT Vacuum Controllers. www. ElectricalPartManuals. com. Bulletin CC

OVERHEAD DISTRIBUTION SWITCHES

Figure 1. HX cutout fuseholders.

AVX. Operation and Maintenance Manual AVX 1200A A 15kV to 362kV. ALUMINIUM VERTICAL BREAK DISCONNECT SWITCH 15kV to 362kV 1200A A

Medium voltage switchgear SafeGear HD 63 ka arc resistant metal-clad switchgear. ABB Group February 25, 2015 Slide 1

www. ElectricalPartManuals. com SPECIFICATIONS Page 1 of 24 March 24, 2003

Design Standard. Purpose: Design Standard:

Power Fuses. > Power Fuses > BPA & HPA kv AMPs

Figure 1. HX cutout fuseholders. Positive Interruption

Medium Voltage Metal-Enclosed Switches

Instructions for Installation and Operation

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

Power & High Voltage Joslyn Hi-Voltage Overhead Reclosers & Switches H-220. Series HVI Hi-Velocity Interrupter Attachment

HUBBELL Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Joslyn Hi-Voltage. Overhead Reclosers & Switches. In this section...

Underground Distribution Switchgear

www. ElectricalPartManuals. com lncoming-6900 through 69,000 volts Outgoing-2400 through 13,800 volts Ratings:

F1-1 ACCESSORIES AND SPARE PARTS FOR DRIWISA EQUIPMENTS INDOOR SERVICE OVERVIEW DRIESCHER Y WITTJOHANN, S.A.

Solid Dielectric, Single Phase Recloser

Specifications. S&C Omni-Rupter Switches Outdoor Distribution (14.4 kv and 25 kv) Conditions of Sale

SecoVac * Ground & Test Device

www. ElectricalPartManuals. com Instructions for Load Break Air Switch, Type LBF, for Power Centers

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

TYPE PSI/II PADMOUNT SWITCHGEAR 15KV 25KV

C1000 Series Automatic Cap Bank

Switchgear. Low Voltage

920 Remote Control Switches

Specifications. S&C Mini-Rupter Switches Indoor Distribution (4.16 kv through 25 kv) Manually Operated Styles

S&C Series 2000 Circuit-Switchers Outdoor Transmission 69 kv through 230 kv

GE CONSUMER & INDUSTRIAL

Descriptive bulletin. ReliaGear ND ANSI narrow frame metal-clad switchgear

Specifications. S&C Alduti-Rupter Switchesa Indoor Distribution (4.8 kv through 34.5 kv) Conditions of Sale SPECIAL TO THIS PRODUCT: How to Order

Three-Phase Pole Mounted Recloser

Westinghouse Electric Corporation Distribution and Control Business Unit Assemblies Division Bloomington, Indiana

Load Break Switch Type LBOR-II, Oil Immersed PTAT-LIR975 IZUA Technical Guide Nut Mount Weld Mount

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT

Transfer switch OTEC open or delayed transition

.1 Low Voltage Switchgear Magnum DS Switchgear with Molded Case Circuit Breaker Feeder Section Cross-Reference Eaton s Electrical Sector has an organi

SWITCHGEAR DIVISION PRODUCT PROFILES

Advance 27 ANSI 27 kv switchgear

16.13 Unit Substation to 15kV Construction Standards Page 1 of 7

OTEC Transfer switch open transition

35-kV Thru-Bushings F Series (bolt-in) for Air-Insulated to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Wastewater Solutions. DECONTACTOR TM Series. Featuring Meltric s. Switch Rated Plugs, Receptacles and Electrical Connectors

Critical Power Switchboards. Selection and Application Guide

Instructions for Installation and Operation

Transcription:

Bulletin DB-106C05 Type V2-C Copper Vertical Break Switch 7.2-69 kv 600-2000 A.

Designed for Simplicity V2-C APPLICATION The Cleaveland/Price V2-C is a three pole, group operated, copper vertical break switch for installation in substation or distribution line locations. The switch can be mounted in the horizontal-upright, vertical, or horizontal-underhung position. The V2-C is suitable for use in a variety of applications including line disconnecting and sectionalizing, circuit breaker by-pass and isolation, and transformer isolation. Arc horns or quick break whips are supplied when small amounts of transformer magnetizing currents and line charging currents must be interrupted. 3 Accessories and options needed to adapt the switch to a customer s particular requirements are available. The V2-C may be manually operated by use of a swing handle or wormgear mechanism or electrically operated by use of a type TP-C2 motor operator. The V2-C is designed to meet NEMA and IEEE Standards and the rating requirements of applicable IEC Standards. 4 5 6 7 8 1 2 5 9 Permanently lubricated, maintenance-free sleeve bearing. Rotating insulator bearing does not extend below the housing base to interfere with the mounting structure. 10 1 2 Unbreakable, non-cast copper terminal pads with NEMA standard hole pattern Fully insulated journal bearing 6 7 Silver-to-silver contacts at hinge and jaw Stainless steel contact springs insulated from the current path 3 4 Unbreakable, non-cast operating crank Stainless steel counterbalance springs that are insulated from the current path 8 9 Hard-drawn, high conductivity copper contact fingers at hinge and jaw Plain or tin-plated terminal pads 5 Hard-drawn, high conductivity copper current-carrying parts 10 Hot-dipped galvanized steel base

Engineered for Performance THE CLEAVELAND/PRICE APPROACH Cleaveland/Price has a very basic approach to design... keep it simple. It is an approach that is employed from material selection to mechanical design. The Cleaveland/Price V2-C disconnect switch current carrying parts are manufactured from high strength, high conductivity copper. All switches are of non-cast design for superior dependability of parts. Switch performance is not troubled by flaws that could occur in the casting process. Contacts are designed to take advantage of electromagnetic forces by using a reverse loop configuration at both the hinge and jaw of the switch. Current transfer points are kept to a minimum. PROBLEM: When the switch blade on a conventional switch rotates in the breakjaw to the final blade position, it does not consistently stop at the point of optimum contact pressure. The resulting inadequate contact pressure may cause contact pitting and burning. Many switches use a stop on the rotating insulator to try to set proper blade position. This type of stop is too remote from the blade to accurately control the blade motion because of the cumulative play in the linkage joints. Variation in the speed of the operator can actually affect the amount of blade turnover. SOLUTION: On the Cleaveland/Price V2-C, the blade stop is on the blade itself instead of CUTAWAY VIEW HINGE PIN an intermediate linkage point (the rotating insulator). The V2-C stop location assures that blade rotation in the break-jaw will accurately and consistently stop at the point of maximum contact pressure. The cutaway view shows how the unique Cleaveland/Price turnover stop allows the blade to rotate until the slot in the blade engages with the hinge pin. This sets the proper turnover angle. The stop angle is factory-machined for built-in accuracy. No matter how fast or slow the blade moves, it doesn t stop moving until it has fully turned over. STOP ROTATION IN BREAK-JAW IS CONTROLLED BY THE STOP CLEAVELAND/PRICE FEATURES FOR OUTSTANDING PERFORMANCE AND LONG LIFE The V2-C is made of the finest materials for dependable, Open construction of the hinge and smooth non-cast trouble-free service. Knowledge gained from maintaining surfaces throughout, enabling the V2-C to break ice switches in the field for over 60 years has played a major with amazing ease part in refining the V2-C. Significant design features include: Wiping action on both the break-jaw and hinge keeps Total non-cast copper and steel construction resulting contacts clean for years of reliable service in the superior dependability of parts Visable hinge contacts allow easy verification of Live parts constructed from hard-drawn, high conductivity copper producing stronger, more conductive compo- Reverse loop electromagnetic design at hinge and contact condition without disassembly nents than parts made of cast materials break-jaw on all ratings gives outstanding performance under fault Silver-to-silver moving contacts conditions

Exclusive Cleaveland/ Price V2-C Features The Cleaveland/Price V2-C is an advanced design vertical break switch with features of genuine value to the customer. It incorporates several patented improvements: 1. Positive blade turnover stop is the key to consistent and complete contact pressure to prevent contact burning. 2. Insulating journal bearing prevents current flow through the live operating linkage. 3. Floating break-jaw contacts allow blade and break-jaw fingers to move together under short circuit and seismic duty to outperform conventional contact systems. FEATURE FOR EASY ADJUSTMENT UNIQUE BREAK-JAW DESIGN Short circuit tests prove that the V2-C break-jaw is superior to conventional break-jaws. On the V2-C, phase-to-phase electromagnetic forces that pull the blade side-to-side do not decrease the contact pressure since the fingers of the jaw are joined together to create a floating spring system that moves with the blade. Maximum contact pressure is maintained on all contact surfaces during short circuit and seismic events. ADVANCED V2-C BREAK-JAW maintains consistent contact pressure as blade and jaw fingers move to the side together as a unit under short circuit forces. CONVENTIONAL BREAK-JAW loses contact pressure as the blade moves to the side because of electromagnetic forces. ANSI standards require that a switch pass the rated short circuit test only once. Standards also allow live parts to be changed for each test. The V2-C gives greater confidence in short circuit performance as demonstrated by 12 consecutive test shots on a 2000 amperes switch using the same set of live parts. PIVOTING HINGE During installation, the blade may be misaligned with the break-jaw, requiring adjustment of the insulators. However, it is often easier to pivot the blade to attain alignment with the jaw contact. This is particularly true when bus and ground blades have been installed at the jaw terminal and the blades are not perfectly adjusted. By loosening the bolts that attach the hinge and jaw to the stationary insulators and closing the switch, the blade and jaw automatically seat themselves in the proper alignment. Retighten the bolts and the adjustment is complete without having to realign the ground switch or bus.

Type V2-C Copper Vertical Break Switch 4 (600, 1200, 1600A) 6 (2000A) Nom. Max. KV Ins. Amp. Mom. Switch A B C D E F Wt./ kv kv BIL TR# ka Style Number Pole 600 40 C06A034G01 145 34.18 1200 61 C06A034G02 14.68 151 7.2 8.3 95 202 7.5 41 15 7 1600 70 C06A034G03 34.43 153 2000 100 C06A034G04 14.93 35.93 165 600 40 C06A034G05 163 36.68 1200 61 C06A034G06 17.18 169 14.4 15.5 110 205 10 41 15 10 1600 70 C06A034G07 36.93 171 2000 100 C06A034G08 17.43 38.43 183 600 40 C06A034G09 193 49.68 1200 61 C06A034G10 21.18 200 23 27 150 208 14 50 24 12 1600 70 C06A034G11 49.93 203 2000 100 C06A034G12* 21.43 51.43 217 600 40 C06A034G13 227 53.68 1200 61 C06A034G14 25.18 235 34.5 38 200 210 18 50 24 18 1600 70 C06A034G15 53.93 238 2000 100 C06A034G16* 25.43 55.43 251 600 40 C06A034G17 283 63.68 1200 61 C06A034G18 29.18 291 46 48.3 250 214 22 56 30 22 1600 70 C06A034G19* 63.93 295 2000 100 C06A034G20* 29.43 65.43 309 600 40 C06A034G21 396 81.68 1200 61 C06A034G22* 37.18 405 69 72.5 350 216 30 66 40 32 1600 70 C06A034G23* 81.93 410 2000 100 C06A034G24* 37.43 83.43 426 * Counterbalanced ratings

Operators / Accessories Ordering Information Furnish: Switch type Voltage Amperage Momentary rating BIL level Mounting position Operator type Accessories required Swing Handle Operator Motor Operator Type TP-C2 Handcrank Operator Standard Operator Features Swing handle operator Padlock provision in both the open and closed positions Ground strap for vertical operating pipe Adjustable stops Clamp-on open/closed indicators Self-lubricating, maintenance-free outboard bearing 1-1/2 IPS galvanized steel vertical operating pipe Available Accessories Arc horns Auxiliary switch Braidless ground contact Electrical interlock Extended operator Ground blades Ground blade mechanical interlock Insulated vertical pipe Interrupting device Key interlock Mounting hardware Operator grounding platform Outriggers Quick break whips Spill gaps Terminal connectors This brochure describes our standard product and does not show variations in design that may be available. Contact the factory for additional details. Cleaveland/Price reserves the right to make changes or improvements to the product shown in this brochure without notice or obligation.