Panorama. Softstarters The complete range

Similar documents
U.S. CATALOG. Softstarter Type PSR, PSE and PSTX

Catalog. Softstarters Type PSR, PSE and PSTX

CATALOG. Softstarters PSR, PSE and PSTX

Catalog. Softstarters Type PSR, PSS, PSE, PST and PSTB

Softstarters from ABB. ABB Low Voltage Products. Controlling the elements

PSE The efficient range Description

Softstarters Type PSR, PSS, PSE, PST and PSTB

Catalog. Softstarters Type PSTX and PSTB

Softstarters. Main Catalogue. Type PSR Type PSS Type PST/PSTB

Phone: Fax: Web:

Softstarters Softstarters

US Brochure. Tmax XT Molded case circuit breakers Simply XTraordinary

US Panorama. New SACE Emax 2 UL 1066 From Circuit Breaker to Power Manager

Catalog. Softstarters Type PSR, PSE, PST and PSTB

Variable speed drive or soft starter?

Softstarters PSR PSS PST Extreme duty

Thermal overload relay TF140DU and TF140DU-V1000

ABB Softstarter Benefits Charnchanok Thongprad

The PSE Softstarter Easy and Reliable with LCD display and torque control

Thermal overload relay TF65 and TF96

Electronic overload relays EF205 and EF370

Softstarters Type PSS Type PST/PSTB - New range. New. Catalogue 1SFC132001C0201, Revised in October SFC132016F0201

Softstarters Type PSTX30...PSTX370 User Manual short form 1SFC132082M9901

Softstarters. Catalogue. Type PSR. Catalogue 1SFC132003C0201 (1SFC132152F001)

Manual motor starters Overview and benefits

Electronic overload relay EF65, EF96 and EF146

Softstarters Type PSS. Softstarters. General information

Starts, stops and protects. Emotron TSA Softstarter

US CATALOG. ProLine Panelboard and breakers

Softstarters. The PSTB "Advanced" softstarter line Same features as PST except PSTB softstarters include ABB AF contactors for by-pass.


Thermal Overload Relays

CTi Automation - Phone: Fax: Web:

ABB Softstarters The new PSS line from 3A to 515A

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation MAKING MODERN LIVING POSSIBLE

Product information. ECOSS Electronic compact starter for wound rotor drives

ABB solutions for control panels Capabilities guide

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

Softstarters Type PSR. Softstarters

Mini contactors B6, BC6 with 3 pole

VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 3000

a revolution in soft start motor control The future of soft start motor control at your fingertips

MAKING MODERN LIVING POSSIBLE. Operating Instructions. VLT Soft Starter - MCD500

The future of soft start motor control at your fingertips

Softstarters. Type PST. Softstarters

For Operation in the Control Cabinet 3RW Soft Starters

MAKING MODERN LIVING POSSIBLE. VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 500

Features and Benefits. Control Features

RVS-DN Digital Reduced Voltage Motor Starter

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

MCD 500 Operating Instruction. Safety 5 Warnings 5. Feature List 7 Type Code 8. Mechanical Installation 9 Dimensions and Weights 10

Brochure. Motor protection and control DRAS enclosed direct-on-line starters

RVS-DX Digital Reduced Voltage Motor Starter

BROCHURE. IE4 SynRM motor-drive packages Super premium efficiency for industry

TECHNICAL CATALOG. ReliaGear SafeT interiors OEM power distribution interiors for panelboards and switchboards

Short form catalogue Motor protection and control Manual motor starters

Game changing soft starters

Application Description

A softstarter beyond the ordinary

ABB s new control and protection devices

Operating Instructions. VLT Soft Starter - MCD 500. Phone: Fax: Web: -

AUCOM NORTH AMERICA. Complete range of motor starting solutions

3RW Soft Starters. General data. 6/2 Siemens LV 1 N SIRIUS Soft Starters 01/2008. Siemens AG 2008

a revolution in soft start motor control The future of soft start motor control at your fingertips

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

DRAFT 1400HP 1000HP 100HP. Reduced Voltage Solid State Starters. Softstarters SOFT. PF Controller PCS Controller PDS Controller V 1...

RVS-AX Instruction Manual

Short form catalogue Fusegear BS and DIN type HRC-fuse links OFFN_, OFAF_H, OFAA_GG. / gg. 4 / gg. OFAA 4gG 800A. OFAA 4gG 800A OFAA. 3gG 400A.

CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O

THE COMPLETE SOLUTION FOR STARTING AND STOPPING AC MOTORS. MCD 3000 Soft starter

Reduced Voltage Starters Section 2

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

EMX3 SOFT STARTER. Take control from the start

VLT Soft Starter. Remote operation. Serial communication 24 V AC/DC V AC. Constant effort to improve MCD 100, MCD 201, MCD 202, MCD 3000

Panorama. Contactors Motor protection Accessories

Product Brochure. Generator Circuit-Breaker HVR-EBCB For hydro or pump storage power plant

BRIDGE-BOY Load limitation electronics with 1 or 3 set points

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

FOR SMOOTH MOTOR CONTROL AND ENERGY SAVINGS. Low voltage AC drives and softstarters Product guide

PQstorI One stop solution for energy storage and power quality

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

SMISSLINE TP Touch proof system Power and Safety

Manual motor starter magnetic only MO325

MCD 200 Series Soft Starters

MEDIUM VOLTAGE PRODUCT CAPABILITIES OVERVIEW

Open Chassis Star-Delta Starter User Guide

ZX-Family Gas-insulated medium voltage switchgear

Reduced Voltage Starters

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

Starting Torque Limiter Type TCI (Soft Start)

AuCom - Soft Starters

SDS Enclosed Star-Delta Starter User Guide

High Performance, High Function System Drive SOFTSTARTER SS7. 2.2kW ~ 1.5MW / 230 ~ 690V. Drive Solution

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

Transcription:

Panorama Softstarters The complete range

Why does soft starting matter? Controlling industrial electricity. The vast majority of the world s industrial applications are driven by motors. It is estimated that 28 percent of all electricity used in one year is dedicated to run industrial motors. Controlling industrial electricity is what ABB softstarters does in an excellent way. Secure motor Reliability With ABB softstarters current peaks are eliminated and the starting current is significantly reduced. The load and voltage protections keep your motor protected from load and network irregularities. Additional features that improve the overall reliability of the motor are three types of current limit and earth fault protection, amongst others. Improve installation Efficiency The built-in bypass will reduce both energy consumption and heat generation while running motors at full speed. It saves installation time and space inside the panels while reducing the cost of extra cooling equipment. ABB softstarters also come with HMI s that are easy to learn, improving the efficiency of the softstarters once they are in use. Increase application Productivity ABB softstarters will reduce mechanical wear and tear and increase the productivity of your applications. With torque control damage to pump systems from problems such as water hammering can be completely avoided. The continuous operation of applications can also be increased by features like jog with slow speed, pump cleaning and limp mode, which allows your application to do more.

Yantai Guhe Electric Improving water supply reliability Manufacturing over 1,000 installation panels for pump systems annually requires the use of reliable motor starting solutions. In the past, Yantai Guhe Electric experienced problems with water hammering when stopping pumps with the panels it built. However, since using ABB softstarters with torque control, this problem has been eliminated. This led to a 20 percent reduction of downtime and a 40 percent reduction in cost. Why soft starting matters to Yantai Guhe Electric Reduction of pump system downtime by 20% Maintenance cost for pump system reduced by 40% For more examples of how ABB softstarters help the industry, visit: new.abb.com/low-voltage/launches/pstx.

PSR The compact range Normal start PSR3 PSR6 PSR9 PSR12 PSR16 PSR25 PSR30 PSR37 PSR45 PSR60 PSR72 PSR85 PSR105 In-line connected (400 V) kw 1.5 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 IEC, max. A 3.9 6.8 9 12 16 25 30 37 45 60 72 85 105 (440-480 V) hp 2 3 5 7.5 10 15 20 25 30 40 50 60 75 UL, max. FLA 3.4 6.1 9 11 15.2 24.2 28 34 46.2 59.4 68 80 104 UL coordination 600 V, 40 ºC J-type fuses for UL UL max. fuse, J-type (85 ka) coordination 1) J-35 J-60 J-90 J-110 J-125 J-150 J-200 UL listed circuit breaker 1) Please see coordination tables at: applications.it.abb.com/soc or at new.abb.com/low-voltage/products/softstarters/pstx. IEC coordination 400 V, 40 ºC Using manual motor starter or IEC manual motor starter (50 ka) MCCB, Type 1 coordination will be achieved. 1) MS116 MS132 MS450 MS495 Using gg fuses, Type 1 coordination will be achieved. To achieve Type 2 coordination, semiconductor fuses must be used. 1) IEC fuse protection (50 ka) gg fuse 10 A 16 A 25 A 32 A 50 A 63 A 100 A 125 A 200 A 250 A Suitable switch fuse for the recommended semiconductor fuses. 1) Switch fuse OS32G OS125G OS25 The line contactor is not required for the softstarter itself but often used to open if OL trips. 1) Line contactor AF9 AF12 AF16 AF26 AF30 AF38 AF52 AF65 AF80 AF96 AF116 Overload protection is always Thermal overload relay required to protect the motor. 1) TF42 TF65 TF96 TF140DU 1) This is an example of a coordination. For more examples, see: applications.it.abb.com/soc. Select softstarter according to load Normal start class 10 Heavy duty start class 30 Bow thruster Centrifugal fan Centrifugal pump Crusher Compressor Conveyor belt (long) Conveyor belt (short) Mill Elevator Mixer Select size according to the motor kw ratings. Stirrer Select a softstarter one size larger compared to the motor kw ratings. In-line or inside delta for PSTX The PSTX softstarter can be connected inside the motor delta, reducing the current by 42 percent. For example, it will then be possible to run a 100 A motor using a 58 A softstarter. In-Line Inside Delta 100 A 58 A 100 A 100 A

PSE The efficient range PSE18 PSE25 PSE30 PSE37 PSE45 PSE60 PSE72 PSE85 PSE105 PSE142 PSE170 PSE210 PSE250 PSE300 PSE370 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 200 18 25 30 37 45 60 72 85 106 143 171 210 250 300 370 10 15 20 25 30 40 50 60 75 100 125 150 200 250 300 18 25 28 34 42 60 68 80 104 130 169 192 248 302 361 600 V, 40 ºC UL max. fuse, J-type (85 ka) J-40 J-50 J-60 J-80 J-100 J-125 J-150 J-175 J-225 J-300 J-350 J-450 J-500 J-600 UL circuit breaker 480VAC (65 ka) T4H250 T5L400 T5H600 400 V, 40 ºC IEC MCCB (50 ka) XT2S160 XT4S250 T4S320 T5S400 T5S630 IEC fuse protection (85 ka), Semiconductor fuses, Bussmann 170M1563 170M1564 170M1566 170M1567 170M1568 170M1569 170M1571 170M1572 170M3819 170M5809 170M5810 170M5812 170M5813 170M6812 170M6813 Switch fuse OS32GD OS63GD OS125GD OS250D OS400D OS630D Line contactor AF26 AF30 AF38 AF52 AF65 AF80 AF96 AF116 AF140 AF190 AF205 AF265 AF305 AF400 Electronic overload relay Built-in PSR Screw or DIN-rail mounted PSE Screw mounting LED indicators Digital input for start, stop and reset Three potentiometers for settings Output signal relays for run, top of ramp and event Output signal relays Clear markings on the front for easy installation

PSTX The advanced range PSTX30 PSTX37 PSTX45 PSTX60 PSTX72 PSTX85 PSTX105 PSTX142 PSTX170 PSTX210 PSTX250 PSTX300 PSTX370 15 18.5 22 30 37 45 55 75 90 110 132 160 200 30 37 45 60 72 85 106 143 171 210 250 300 370 20 25 30 40 50 60 75 100 125 150 200 250 300 28 34 42 60 68 80 104 130 169 192 248 302 361 600 V, 40 ºC UL max. fuse, J-type (100 ka) J-60 J-70 J-90 J-125 J-150 J-175 J-225 J-250 J-400 J-500 J-600 UL circuit breaker 480VAC (65 ka) T4H100 T4H150 T4H250 T5H300 T5H400 T5H600 400 V, 40 ºC IEC MCCB (50 ka) XT2S160 XT4S250 T4S320 T5S400 T5S630 IEC fuse protection (80 ka), Semiconductor fuses, Bussmann 170M1567 170M1568 170M1569 170M1571 170M1572 170M3819 170M5810 170M5812 170M5813 170M6812 170 Switch fuse OS32GD OS63GD OS125GD OS250D OS400D O Line contactor AF30 AF38 AF52 AF65 AF80 AF96 AF116 AF140 AF190 AF205 AF265 AF305 AF370 Electronic overload relay Built-in PSTX Three programmable digital inputs and start and stop Three programmable output signal relays Keyhole mounting for quick installation A compact motor starting solution with many features Clear markings on the front for easy installation and handling Built-in Modbus and Anybus for other protocols Extension I/O for extra inputs and outputs Choose between 15 different measurements for analog out

PSTX470 PSTX570 PSTX720 PSTX840 PSTX1050 PSTX1250 250 315 400 450 560 710 470 570 720 840 1050 1250 400 500 600 700 900 1000 480 590 720 840 1062 1250 L-1200 L-1600 L-2500 T7H1200 T8V3000 T7S800 T7S1250 E2.2N 2000 M6813 170M6814 170M8554 170M6018 170M6020 170M6021 S630D OS800D AF460 AF580 AF750 AF1350 AF1650 Electronic overload relay Built-in Softstarter feature selection guide Increase application productivity Improve installation efficiency Secure motor reliability PSR PSE PSTX Standard O Optional Not available Current limit Current limit ramp and dual current limit Electronic motor overload protection Dual overload protection Underload protection Power factor underload protection Locked rotor protection Current/voltage imbalance protection Phase reversal protection Customer defined protection Motor heating PTC/PT100 input for motor protection Overvoltage/undervoltage protection Earth-fault protection Built-in bypass Inside-delta connection possible Graphical display and keypad Detachable keypad Motor runtime and start count Programmable warning functions Diagnostics Overload time-to-trip Overload time-to-cool Analog output O O Fieldbus communication O Event log 17 Multiple languages Electricity metering Torque control Torque limit Coated PCBA Limp mode Jog with slow speed forward/reverse Dynamic brake Stand still brake Sequence start Full voltage start Kick start Automatic pump cleaning Customizable display for important status information Easy to use because of large graphical display Backlit display makes status information easy to read Detachable HMI for easy panel door mounting Application assistant for fast and easy set-up Information button for built-in help function IP66 (1, 4x outdoor, 12) protection against water and dust USB connection

Contact us ABB Electrification Products 8155 T&B Boulevard Memphis, TN 38125 www.abb.us/lowvoltage USA Technical Support: 888-385-1221 Customer Service: 888-862-3290 7:00 a.m. - 5:30 p.m., CST, Monday-Friday lvps.support@us.abb.com Note We reserve the right to make technical changes or modify the contents of this document without prior notice. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 2016 ABB - All rights reserved 1SXU132225B0201, May 2016