YOUR PETROLEUM STORAGE TANK FACILITY INSPECTION GUIDE

Similar documents
YOUR PETROLEUM STORAGE TANK FACILITY INSPECTION GUIDE

This handbook is provided as a general guide. assistance/content/storage-tank-compliance

(Please type or use black ink)

ANNUAL UST SYSTEM INSPECTION CHECKLIST

Underground Storage Tank Annual Compliance Inspection (Revised 1/2015)

North Carolina Department of Environment and Natural Resources Division of Waste Management Underground Storage Tank Section

Inspector's Initials: Tank Owner or Agent Signature: Title: Date:

6. Tanks - Leak Detection. NCDENR Division of Waste Management Underground Storage Tank Section

FINAL UNDERGROUND STORAGE TANK RULE CHANGES. Heather Peters UST Compliance and Technology Unit

BUREAU OF UNDERGROUND STORAGE TANK REGULATIONS RELEASE PREVENTION SECTION

Changes to Chapter , Florida Administrative Code Underground Storage Tank Systems (USTs) Effective 1/11/2017

Overview of an Underground Storage Tank Inspection

Underground Oil Storage Tanks Annual Inspection Report

PEI/RP Recommended Practices for the Inspection and Maintenance of UST Systems

New UST Installation Inspection Checklist

Lorri Grainawi Steel Tank Institute. PA NISTM April 25, 2013 Harrisburg, PA

OKLAHOMA CORPORATION COMMISSION PETROLEUM STORAGE TANK DIVISION THE ABC S OF AST S AN OVERVIEW OF ABOVEGROUND STORAGE TANK REQUIREMENTS

Operational Compliance Closure/Release Response/Corrective Action at Underground Storage Tank Facilities

NCDEQ Underground Storage Tank Section

Understanding the Colorado Annual Compliance Package. William Holman & Robert Schlegel Inspectors Division of Oil and Public Safety

Monthly Walkthrough Inspections

FACTS ABOUT: MARYLAND CONTAINMENT SUMP TESTING PROTOCOL WHO CAN PERFORM THE TEST

CONTRACTOR S SELF-INSPECTION CHECKLIST for UST INSTALLATION REPLACEMENT UPGRADE RETROFIT REPAIR

UST Compliance Assistance Handbook

Semiannual Report Of UST Performance Measures End Of Fiscal Year 2018 (October 1, 2017 September 30, 2018)

Changes to EPA s AST & UST Rules. Mott-Smith Consulting Group, LLC

UST General Requirements Inspection Checklist

Frequent Mishaps and Solutions with Regulated Underground Storage Tanks in Pennsylvania

NYSDEC CBS Compliance Requirements

Petroleum Storage Tank Release Detection and Inventory Control

Operating And Maintaining Underground Storage Tank Systems. Practical Help And Checklists. Printed on Recycled Paper

Operating And Maintaining Underground Storage Tank Systems. Practical Help And Checklists. Printed on Recycled Paper

P.O. Box 435 Saratoga Springs, NY 12866

PEI/RP Recommended Practices for Installation of Bulk Storage Plants

General information about underground storage tank (UST) fueling systems in every day language.

Operating And Maintaining Underground Storage Tank Systems UPDATED Practical Help And Checklists. Printed on Recycled Paper

Changes to EPA s AST & UST Rules. Mott-Smith Consulting Group, LLC

OKLAHOMA CORPORATION COMMISSION PETROLEUM STORAGE TANK DIVISION THE ABC S OF UST S AN OVERVIEW OF UNDERGROUND STORAGE TANK REQUIREMENTS

Compliance Strategies and Benefits

Mark S. Morgan, Regulatory Counsel

UNDERGROUND STORAGE TANK INSPECTION CHECKLIST

PENNSYLVANIA ABOVE GROUND STORAGE TANKS

Underground Storage Tank. City of Burbank UST Owners & Operators

Form UST FP-290 Notification for Underground Storage Tanks Regulated Under 527 CMR 9.00

NYSDEC PBS REGULATIONS Heating Oil Tanks

UNDERGROUND STORAGE TANK (UST) INSTALLATION & MAINTENANCE

Compliance Strategies and Benefits. Brian Derge Tanknology Inc. December 6, 2012

New UST Regulations. What follows are the changes to EPA s regulations that TMS believes impacts you, the owner/operator, the most.

Provide the following information: Site Address: City: Zip: Project Contact Name: Phone No.: ( ) ext.

INSTALLATION INSTRUCTIONS B-375-D Fiberglass DoubleWall Spill Bucket

Application for Permit to Install Underground Storage Tanks (Petroleum or Hazardous Substances) 1. Owner Information 2. Installation Site Information

RULE 448 GASOLINE TRANSFER INTO STATIONARY STORAGE CONTAINERS Adopted (Amended , , , , , ) INDEX

THE KEY RELATIONSHIPS BETWEEN FIRE CODES, NEW YORK AST REGULATIONS AND SPCC PLANS

South Tacoma Groundwater Protection District Spill Prevention and Response Plan

DEFENDER SERIES. 5 Gallon, Double Walled, Field Replaceable Spill Container Model Series INSTALLATION, OPERATION, & MAINTENANCE

Management of Underground Storage Tanks

NEW JERSEY SMALL BUSINESS ENVIRONMENTAL ASSISTANCE PROGRAM. New Jersey Fuel Dispensing Facilities Compliance Calendar

County of Yolo UNDERGROUND STORAGE TANK PROGRAM INSTALLATION/MODIFICATION/REPAIR APPLICATION

Pennsylvania DEP: Maintaining UST Compliance and Regulation Updates. NISTM 8 th Annual Pennsylvania Storage Tank Conference May 18, 2017

Code Requirements for ASTs at Motor Vehicle-Dispensing Stations

NEW JERSEY SMALL BUSINESS ENVIRONMENTAL ASSISTANCE PROGRAM. New Jersey Fuel Dispensing Facilities Compliance Calendar

E. Augusta, Spokane, WA (509) E. Augusta, Spokane, WA (509)

Overview of Revisions to the Federal Underground Storage Tank (UST) Regulations. Storage Tank Advisory Committee Harrisburg, PA September 1, 2015

Air Quality Requirements for Gasoline Dispensing

EPA UST Regulations Update May 22, 2018

Underground Storage Tank Certification Examinations. Presentation to ASTSWMO November 27, 2007 UST SYSTEM OPERATOR CERTIFICATION

7. UST Piping Corrosion Protection. NCDENR Division of Waste Management Underground Storage Tank Section

Test Date: 3/30/2018 Order Number: Dear Regulator, Enclosed are the results of recent testing performed at the following facility:

PURPOSE RESPONSIBILITY

The penalties for violating air pollution regulations can be $10,000 per day or more. Notice of Violation (NOV)

NEW JERSEY SMALL BUSINESS ENVIRONMENTAL ASSISTANCE PROGRAM. New Jersey Fuel Dispensing Facilities Compliance Calendar

How to Comply with Federal and Florida DEP UST Rules and Avoid Petroleum Discharges to the Environment. Mott-Smith Consulting Group, LLC

401 KAR 42:020. UST systems: design, construction, installation, and registration.

UST Inspector Reference Handbook

Preventing Leaks and Spills at Service Stations. A Guide for Facilities

COLORADO DEPARTMENT OF LABOR AND EMPLOYMENT DIVISION OF OIL AND PUBLIC SAFETY STATISTICAL INVENTORY RECONCILIATION (SIR) GUIDANCE DOCUMENT

Notification for Underground Storage Tanks

1) Activity Description: Management of Petroleum Storage Tanks and Containers

Winning Bid US Petroleum Equipment Walts Petroleum Northwest Petroleum Petro-Chemical Systems Kimberly Green Bay Wausau Fond Du Lac

PETROLEUM PRODUCT STORAGE TANK REGULATION SAFETY AND BUILDINGS DIVISION BUREAU OF PETROLEUM INSPECTION AND FIRE PROTECTION

NEW JERSEY SMALL BUSINESS ENVIRONMENTAL ASSISTANCE PROGRAM. New Jersey Fuel Dispensing Facilities Compliance Calendar

CONTENTS. Foreword...iii. 1. Introduction...1

Summaries for Gasoline Distribution Facilities and Gasoline Dispensing Facilities 40 CFR 63 subpart BBBBBB and 40 CFR 63 subpart CCCCCC

Grant Guidelines To States For Implementing The Secondary Containment Provision Of The Energy Policy Act Of 2005

Ohio EPA. Division of Air Pollution Control. Engineering Guide #12

4. No person shall install a coaxial Phase I vapor recovery system unless the system was certified by CARB after January 1, 1994.

State of California AIR RESOURCES BOARD EXECUTIVE ORDER VR-302-B

9.21 Tank Program Guide NYS Office of Mental Health Tank System Installation Guide

Storage Tank Systems for Petroleum Products and Allied Petroleum Products Regulations

APPLICATION for BUSINESS LICENSE Licensing & Permits City of Williston PO Box 1306, Williston, ND

ECM environmental compliance monitoring, inc. 1

Steel USTs: History and Trends. Wayne Geyer, STI/SPFA August 1, 2013

GENERAL PLAN APPROVAL AND GENERAL OPERATING PERMIT BAQ-GPA/GP 2 STORAGE TANKS FOR VOLATILE ORGANIC LIQUIDS

Leak Detection for Petroleum UST and Piping

Syracuse University Petroleum Bulk Storage Tank Program Manual

NYS DEPARTMENT OF ENVIRONMENTAL CONSERVATION CLASS C OPERATOR TRAINING

How a UST Site May Become Contaminated -- Even When The Leak Detection is Passing

Pennsylvania DEP Aboveground Storage Tank Facility Visits NISTM PA CONFERENCE Washington, PA May 18, 2017

New Tank Installations. Peter Rollo

LEAK DETECTION INTERSTITIAL MONITORING

Transcription:

YOUR PETROLEUM STORAGE TANK FACILITY INSPECTION GUIDE HOW WELL DO YOU KNOW YOUR PETROLEUM STORAGE AND DISTRIBUTION SYSTEM?

This handbook is provided as a general guide. For specific regulation requirements refer to the underground and aboveground storage tank system rules (Chapter 62-761 and Chapter 62-762, Florida Administrative Code) which are located at the district and county offices, and at the storage tank program web site (www.dep.state.fl.us/waste/categories/tanks/default.htm). TABLE OF CONTENTS A. Records and Certificates to be Kept on File... 1 B. Internal Leak Detection Systems... 2 C. External Leak Detection Groundwater and Vapor Monitoring Wells... 3 D. Dispenser Assembly and Components... 4 E. Dispenser Hose Nozzles, Pressure Vent Valves and Vent Pipes... 5 F. Fill Areas Assembly with Color Coded Covers... 6 G. Sump Pump and Containment Assembly... 7 H. Double Wall Storage Tanks... 8 I. Double Wall Piping... 10 J. Aboveground Fuel Dispensing System with Dispenser... 11 K. Fuel Dispensing System Assembly and Exploded View of Commonly Used Components... 12 L. Aboveground Fuel Storage Tanks Installation... 14 M. Specifications for Aboveground Storage Secondary Containment Construction... 15 N. Aboveground Emergency Generator Fuel Tank Storage Installation... 16 O. Fuel Dispensing System and Aboveground Visual Inspection Check Sheets... 17 Handbook Guide For Petroleum Storage Tank Systems Prepared by Broward County Environmental Protection Department Pollution Prevention and Remediation Division for the Florida Department of Environmental Protection (FDEP) Division of Waste Management Bureau of Petroleum Storage Systems Inclusion of specific equipment brands within this document is intended for information purposes only and does not constitute endorsement of these products. For a list of FDEP approved equipment, see: http://www.dep.state.fl.us/waste/categories/tanks/pages/equip.htm Comments herein on Stage I and II Vapor Recovery Systems are not applicable to all counties.

A. RECORDS AND CERTIFICATES TO BE KEPT ON FILE IT S GOOD FOR YOUR BUSINESS AND IT SAVES INSPECTION TIME! Remember that the law requires you to keep certain records about your storage tank system. Inspectors will ask to see these records. DISPLAY THESE DOCUMENTS WHERE EVERYONE CAN SEE THEM 1 2 3 1. The current FDEP Registration Placard. Remember to check the placard for the proper address. 2. Current certification of financial responsibility. 3. Current local government permit, if applicable. YOU DON T HAVE TO DISPLAY THESE RECORDS, BUT DO KEEP THEM ON FILE Figure 1 Figure 2 Keep these Records for At Least Two Years Storage tank fuel inventory, including tank water level. Monthly release detection results. Electronic release detection equipment monthly function checks. Monthly maintenance visual examinations and results. The presence of regulated substance s odor, sheen or free product. A copy of all test data results. Tightness, pressure and integrity tests. Repair, operation and maintenance records. Certificate of Financial Responsibility. Keep these Records for the Life of the Storage Tank System Manufacturer s performance claims for your leak detection system. Dates of upgrades or replacement of the storage tank systems. Results of internal inspections. Installation, maintenance, inspections and testing of cathodic protection systems. Storage system installations, replacements and upgrades. Closure assessment report if facility is still operating. Written Release Detection Response Level information.

B. INTERNAL LEAK DETECTION SYSTEMS All facilities must have internal or external release detection equipment for their storage tank systems. (Please refer to Chapter 62-761 and Chapter 62-762, Florida Administrative Code, for more information.) Commonly used continuous automatic leak detector systems & fuel dip stick. Remember to check these items monthly and record the results. 1. Automatic Tank Gauges Figures 1, 3, and 5 TLS-350, CEI-3000, VEEDER-ROOT and SMART CEI, Continuous Automatic Leak Detector System Figure 1 will give you one or more readings that may include inventory records, line leak monitoring, UST monitoring, test history, and UST water level. For a list of FDEP approved equipment, see: http://www.dep.state.fl.us/waste/categories/tanks/ Figure 6 pages/equip.htm or call your local Petroleum TLS-350 Storage Tank program. Figures 2 and 4 ILS-350 and TMS-3000, respectively. These systems will provide in-line leak detection only. Figure 2 Figure 3 2. SIR A release detection method for UST s where statistical analysis of inventory, delivery, and dispensing data is used to identify possible leaks. 3. Interstitial Monitoring Typically associated with double wall UST s and underground piping systems, product leaked from the primary containment is directed toward an interstitial monitor located in the space between the primary and secondary containment walls. Figure 5 CEI-3000 Figure 4 SMART CEI General Concerns About Leak Detection Inspect the system at least monthly and record the inspection results. Electronic or visual interstitial monitoring must be conducted for all double-walled UST s and underground piping. Inventory reconciliation must be conducted monthly on single walled UST s. For those systems without inventory reporting features, inventory must be checked manually using a dip stick (Figure 6). When using a stick, check its condition. Wear and tear on the stick, especially at the ends, can result in inventory discrepancies. Make sure the stick is being used right side up. 2

C. ETERNAL RELEASE DETECTION - GROUNDWATER AND VAPOR MONITORING WELLS If you have groundwater or vapor monitoring wells, they must be checked monthly and the results recorded. Inspectors will always look for these results. 3 1 2 3 4 5 6 7 1. Compliance Monitoring Well Cover (black triangle on white cover). 2. Redesignated Assessment Well Cover (white circles on black cover). 3. Monitoring Well Containment with Grouting at Bottom Routinely check grouting with a screwdriver or equivalent to ensure the grouting is intact. (Solid grouting is necessary to prevent surface runoff or spills from entering the soil through the well containment area.) 4. Monitoring Well Cap with Lock Well cap must be kept locked or secured with lock or clips. Lock keys must be available onsite. The cap must be watertight. 5. Monitoring Well Pipe This pipe must be a minimum of at least one inch above the surface of the grouting (to help prevent standing contaminated liquid from entering into the well when the cap is removed). 6. Monitoring Well Acrylic Bailer with Cord Keep the bailer and cord clean. When sampling wells, care should be taken if one well has signs of contamination (otherwise, wells will be cross contaminated). Bailers should be cleaned between each well sampling. A disposable bailer may be used. 7. Monitoring Well Probe Check the integrity of wires and connections. (If applicable) 8. Monitoring Well Use at Previously Contaminated Sites make sure that the monitoring system used is approved by the state as being approved to detect new releases above background. 3

D. DISPENSER ASSEMBLY AND COMPONENTS On a monthly basis, visually inspect the dispenser and assembly for any problems. Record these monthly checks in a log to demonstrate that the inspections are being completed. Routine inspection will identify problems early, before they develop into serious costs, and will ensure the equipment works to reduce emissions and leaks. 5 7 1 9 10 11 9 1. Dispenser Assembly Covers should be lockable and keys should be available for monthly inspection. When looking inside the dispenser, check the pipe fittings, emergency shut off (or shear) valves (make sure you have one on each fuel line), fuel filters, dispenser liners or secondary containment, leak detection sensors, and cathodic protection anodes. (Your dispenser may not need all these items.) 2. Dispenser Island Keep free from open cans or containers to avoid costly accidents. 2 3 6 12 See Tear 5 8 4 See Flattened Section 3. Stage Two Vapor Recovery Breakaway Valve (If applicable) Check for leaks at connections. 4. Dispenser Hoses For coaxial hoses (if applicable), check for flattened areas, especially at the loop section. Also look for any cuts or tears in the hoses. 5. Vacuum Pumps Listen to hear if both pumps are working (pumps may also be mounted inside dispenser roof). 6. Continuous Automatic Leak Detection Sensor (If applicable) Check connections. Check height of sensor from secondary containment bottom. The leak detection system should alarm when there is a fuel leak or an excessive amount of liquid in the dispenser sump. 7. Fuel Filter Check filter connection and condition on each fuel line. Change if necessary. 8. Cathodic Protection Systems Anode Check wire connection to anode and connection to steel pipe. (If applicable) 9. Emergency Shut Off or Shear Valve Check valve lever and connection to bracket, as shown. (There should be one shear valve for each fuel line. If applicable) 10. Dispenser Piping Sump Secondary Containment Check for cracks and for excessive amount of liquid in containment. Liquid must be pumped out and safely disposed of. 11. Flex Pipe Connection Check for tears or breaks. (May not be accessible.) 12. Primary and Secondary Containment Pipes Pipes should slope back to storage tanks to ensure that, in the case of any line break, product will flow back to the storage tanks. (It is unlikely pipes will be visible for inspection.) 4

E. DISPENSER HOSE NOZZLES, PRESSURE VENT VALVES AND VENT PIPES NOZZLES Some commonly used nozzles for Stage II vapor recovery systems (if applicable). Check these regularly for defects. Balance Nozzle Check face plates for cuts and tears. Check bellows for cuts and tears. Standard Dispenser Nozzle (Not applicable for Stage II Vapor Recovery System) 1. Check hose adapter for tight fit. 2. Standard Dispenser Hose. Vacuum Assist Nozzle Check face cone wear. Check for cuts and tears. UST VENT LINES Vent lines are important because they allow pressure within the tank to equalize when product is removed from the tank. Note: vent lines should extend a minimum of twelve feet above ground level. (Vent lines are not regulated under Rule 62-761, F. A. C.) Figure 1. Pressure Vent Valve. This valve must be in place at all times. This also prevents debris from falling into the tank. Figure 2. Storage Tank System Vent Lines. Each vent line represents one underground tank. A pressure vent valve must be in place for each vent line. Figure 3. Vent Line Manifold. This type of assembly requires only one pressure vent valve. 1 2 OPW Model for Dresser Wayne Vacuum System Nozzle Check face plates and vapor collection holes 1 1 3 Bootless Nozzle Check for spring in place around nozzle spout. Check vapor collection holes. Healy Nozzle Check transparent guard for cuts and tears. 5

F. FILL AREAS ASSEMBLY WITH COLOR-CODED COVERS FILL AREAS 1 2 3 9 8 10 7 11 14 12 13 14 4 5 6 Fill areas are the connections where UST s are filled, typically by a gravity drop through a vertical or remote fill pipe. These apply only to AST s where the fill is at grade and the AST is below grade. Note that special colorization is required for fill covers. This helps prevent accidental filling of the wrong fuel into the wrong tank. Coding should be both on the cover and a second, non-removable portion of the fill. This will prevent problems associated with accidental switching of covers. Visually inspect all these components monthly. 1. Hi-Grade Fill Cover. Red with a white cross. 2. Mid-Grade Fill Cover. Blue with a white cross. 3. Low-Grade Fill Cover. White with a black cross. 4. Low Sulfur Diesel Fill Cover. Yellow. 5. Used Oil Cover. A blue square. 6. Hi-Sulfur Fill Cover. Yellow, with a blue dash. 7. Stage I Dry Break Cover. Orange. 8. Fill Containment. (Spill Protection usually a Spill Bucket ) Check for liquid accumulation and interior seam integrity. 9. Fill Pipe with Cap. Cap should be lockable and watertight. 10. Release Valve. This must only be used to release fuel from the fill containment back into the tank (typically used during refueling of the tank). Any other liquids that accumulated in this area should be removed manually and must be safely disposed of. 11. Stage I Dry Break Poppet Cap with Gasket. Ensure cap fits tightly. (If applicable) 12. Stage I Dry Break Poppet. (If applicable) Press spring loaded valve in center for spring compression reaction. Poppet caps must be in place at all time except when storage tanks are being fueled. 13. Spill Protection/Containment. Check containment integrity for cracks or rust, especially around the interior seams. Hydrotest annually for integrity. 14. Overfill Devices. These devices are designed to prevent overfilling of the storage tank. Do not allow these devices to be disabled. 6

G. SUMP PUMP AND CONTAINMENT ASSEMBLY Complete a visual inspection of sumps monthly unless equipped with sump sensor. If so, periodic visual inspection is recommended. The sump is the area housing the submersible turbine pump. 1 1. Sump Pump Access Cover Remove cover with caution to avoid dropping the cover onto the sump containment cover, which may result in damages. 2. Sump Containment Cover This must be fitted tightly to minimize the intrusion of liquid into the sump containment, which can result in an accumulation of sufficient quantity to trip the leak detection system alarm. 2 3. Sump Containment Check for cracks or holes. Check after rain events to confirm the sump cover is water tight. 4. Fuel Sump Pump Assembly Check all connections for sweating or leaks. 5. Test Boots Test Boots or Reducing Tees may be used to pressure test outer wall piping. The boots must be pulled back from the secondary lines, and the reducing tee test port must be unplugged after lines have been tested. If this is not done, any leakage into the outer wall piping will not flow into the sump and alert you that there is a leak in the primary piping. 6. Flex Connectors a. Flexpipe - Check connections for elongation, swelling, materials degradation, ballooning, leaks, holes. b. Semi-rigid - Check connections for leaks, elongation, swelling. c. Rigid Pipe - Check connections for cracks, leaks. 7. Continuous Automatic Leak Detection System Sensor (If applicable) Check connection and height from bottom of containment. There should be a maximum of about 2 inches from the sensor tip to the bottom of the sump containment. 8. Double Wall Pipes - see page 10. 9. Double Wall Tanks - see page 8-9. 3 8 5 7 6 5 4 5 9 7

H. DOUBLE WALL UNDERGROUND STORAGE TANKS The main component of the storage tank system. By December 31, 2009, all underground storage tanks must be double walled or have some other type of secondary containment. 2 9 3 4 5 8 1 7 6 Typical Tank with Components 1. Double wall fuel storage tank 2. Piping submersible pump 3. Fill pipe with spill containment 4. Interstitial monitoring device 5. Monitoring well with sensor and containment (If applicable) 6. Continuous automatic leak detection sensor 7. Lead wire to continuous automatic leak detection control panel 8. Fuel line 9. Fuel sensor Double Wall Fiberglass Tank with Factory Sealed Interstice using Vacuum Monitoring 5 1. Outer wall 2. Polyethylene Mesh (creates interstitial space) 3. Inner wall 4. Vacuum line and gauge 5. Vacuum monitoring gauge 6. Fuel line 7. Vent line 8. Fill pipe 9. Stage One vapor recovery (If applicable) 10. Spill containment with cover 11. Submersible pump 12. Sump containment cover 13. Drop tube 14. Strike plate 12 12 11 10 7 8 6 10 4 9 2 13 3 1 14 8

Double Wall Steel Tank with Cathodic Protection 1. Piping sump 2. Leak detection 3. Submersible turbine pump 4. Double-wall as shown with Dielectric coating 5. Overfill protection (Ball valve type may also be used) 6. Spill containment and fill pipe 7. Stage One vapor recovery (if applicable) 8. Vent line fitting 9. Galvanic anode (Prevents corrosion) 10. Lifting lugs 11. Certified stamp 2 1 3 10 4 6 7 5 10 8 STEEL 9 11 sti-p3 9 sti-p3 Double Wall Tank - Composite (Fiberglass Coated Steel) 1. Primary tank 2. Fibre 360 interstitial structural layer 3. Fiberglass secondary containment 4. Accessway for sump 5. Lifting lugs as required 6. Monitoring openings - on tank centerline 4 5 6 5 1 2 3 6 6 2 Internal Secondary Containment A rigid inner tank installed within a new or existing single-wall tank. 1. Existing rigid tank - Seconday containment 2. New rigid inner tank - parabeam 3. Drop tube 4. Strike plate 5. Spill containment 6. Supply line 1 7. Vent line 8. Piping sump and containment 9. Liquid collection sump 10. Liquid sight glass 11. Vacuum line 12. Vacuum line to vacuum and pump guage 13. Interstitial space 3 4 5 2 13 7 8 6 10 11 9 12 9

I. DOUBLE WALL PIPING For electronic leak detection systems, the TYPE of piping in a system will affect where the release detection sensor would normally be found. For a list of FDEP approved equipment, see: http://www.dep.state.fl.us/waste/categories/tanks/pages/equip.htm 1 2 3 1. Double Wall Fiberglass Coaxial Pipe. This piping has a 90% closed interstice with the remaining 10% of the space packed with very fine sand between the inner and outer walls. Release detection sensor should be placed in the piping sump. 2. Double Wall Semi-rigid with Interstitial Space. On this piping, the release detection sensor is located inside the interstitial space. 5 6 4 3. Double Wall Fiberglass Pipe with Open Interstitial Space. On this piping, the release detection sensor is located inside the interstitial space. 4. Double Wall Flexible Pipe with Closed Interstice. Release detection sensor should be located in the piping sump. 5. Flex-Pipe with Emergency Shut-off Valve (Shear Valve). This section of pipe is connected from dispenser piping assembly to storage tank piping assembly. 6. Swing Joint Steel Piping Assembly with Emergency Shut-off Valve (Shear Valve). This section of pipe is connected from the dispenser piping assembly to the storage tank piping assembly. Cathodic protection should be installed on this section in the dispenser sump to avoid corrosion of pipes. 10

J. ABOVEGROUND FUEL DISPENSING SYSTEM WITH DISPENSER Do a monthly visual inspection of your aboveground tanks and keep records of the inspection. By January 1, 2010 all above ground field-erected storage tanks must be upgraded with secondary containment. All shop-fabricated tanks must already have secondary containment. A Typical Dispenser A. Storage Tank and Dispenser 1. Check suction pump operation 2. Check vent lines for caps 3. Check fill cap-lock when not in use 4. Check hose retractor operation 5. Check dispenser hose for cracks or crimps 6. Check nozzle boot and faceplate 7. Check outer containment integrity B B. Horizontal Installation of Storage Tank, and Dispenser 1. Check suction pump operation 2. Check vent line for cap 3. Check piping integrity 4. Check containment for liquid accumulation 5. Check containment for proper volume 6. Check tank coating integrity C D C. Horizontal Installation of Double Wall Steel Storage Tank, and Fuel Dispenser (without dike field containment) 1. Check suction pump operation 2. Check vent line for cap 3. Check piping integrity 4. Check containment for liquid accumulation 5. Check tank coating integrity 2 3 4 1 D. Standard Fuel Dispenser (Dispenser liner not shown) 1. Dispenser 2. Dispenser hose 3. Fuel filter 4. Hose support 5. Concrete base 5 11

FILL COVERS PUMP SUMP CO VER USED OIL DIESEL HIGH GRAD E ASSESSMEN T MONI TO RING WELL CO VER DR Y BREAK CO VER BREAKA WA Y VA LV E CONT AINMENT LO W GRAD E COMPLIANCE MONI TO RING WELL CO VER DR Y BREAK FIL L CA P WELL CONT AINMENT PRESSURE VEN T V ALVE PRESSURE VEN T V ALVE NIT MO OR LL PEA FLE PIPE ASSEMBL Y MONI TO RING WELL LL BLE WA S LAS G BER FI DISPENSER S IPE VAPOR VA C PUMP ASSEMBL CONT AINMENT CONT AINMENT MONI TO RING WELL U DO D LLE NK S A W TA E UBL LASS O D RG E FIB TIE DO WN CONCRETE PA D MEMBRANE LINE STEEL TA NK (CA THODICAL LY PR OT ECTED) MONI TO RING WELL K.K.FUEL SYSTEMASSEMBLY ASSEMBLYAND AND FUEL DISPENSING DISPENSING SYSTEM EPLODED OF COMPONENTS COMPONENTS EPLODED VIEW VIEW OF 12 Y SMAR T- VT-TCP MONI TO RING WELL P AU TO MA TIC TA NK GA UG E DOUBLE WA LL FIBERGLAS S PIPES DISPENSER MONI TO RING WELL CONCRETE FOUND ATION MONI TO RING WELL TIE DO WN ASSEMBL Y WITH DEADME N DISPENSER SUMP CONT AINMENT CEI 3000 BALL FL OA T GR CONCRETE FOUND ATION TLS-250 DISPENSER EL AV INSULA TE D PA D LEAK ALER T DISPENSER ISLAN D DR Y BREA K POPPET TIDE L EMS-350 PPN-5000 DISPENSE R VAPO R PUMP S FIL L PIPE MONI TO RING WELL MONI TO RING WELL DISPENSER FUEL LINE S SHEA R VA LVES POPPET CA P WE DISPENSER ASSEMBL Y NOZZLES FILL PRESSURE VEN T V ALVE ING CONT AINMENT CO VER LEAF TYPE WELL CA P VENT LINE S (INDIVIDU AL) ILS-350 TLS-350 FUEL FIL TE R MI D GRAD E FILL CONT AINMENT HI-SULFU R TIE DO WN CONCRETE PA DS ANOD E 13 UNDERG RO UND ST OR AG E TANKS WITH MEMBRANE LINE R R

FILL COVERS PUMP SUMP CO VER USED OIL DIESEL HIGH GRAD E ASSESSMEN T MONI TO RING WELL CO VER DR Y BREAK CO VER BREAKA WA Y VA LV E CONT AINMENT LO W GRAD E COMPLIANCE MONI TO RING WELL CO VER DR Y BREAK FIL L CA P WELL CONT AINMENT PRESSURE VEN T V ALVE PRESSURE VEN T V ALVE NIT MO OR LL PEA FLE PIPE ASSEMBL Y MONI TO RING WELL LL BLE WA S LAS G BER FI DISPENSER S IPE VAPOR VA C PUMP ASSEMBL CONT AINMENT CONT AINMENT MONI TO RING WELL U DO D LLE NK S A W TA E UBL LASS O D RG E FIB TIE DO WN CONCRETE PA D MEMBRANE LINE STEEL TA NK (CA THODICAL LY PR OT ECTED) MONI TO RING WELL K.K.FUEL SYSTEMASSEMBLY ASSEMBLYAND AND FUEL DISPENSING DISPENSING SYSTEM EPLODED OF COMPONENTS COMPONENTS EPLODED VIEW VIEW OF 12 Y SMAR T- VT-TCP MONI TO RING WELL P AU TO MA TIC TA NK GA UG E DOUBLE WA LL FIBERGLAS S PIPES DISPENSER MONI TO RING WELL CONCRETE FOUND ATION MONI TO RING WELL TIE DO WN ASSEMBL Y WITH DEADME N DISPENSER SUMP CONT AINMENT CEI 3000 BALL FL OA T GR CONCRETE FOUND ATION TLS-250 DISPENSER EL AV INSULA TE D PA D LEAK ALER T DISPENSER ISLAN D DR Y BREA K POPPET TIDE L EMS-350 PPN-5000 DISPENSE R VAPO R PUMP S FIL L PIPE MONI TO RING WELL MONI TO RING WELL DISPENSER FUEL LINE S SHEA R VA LVES POPPET CA P WE DISPENSER ASSEMBL Y NOZZLES FILL PRESSURE VEN T V ALVE ING CONT AINMENT CO VER LEAF TYPE WELL CA P VENT LINE S (INDIVIDU AL) ILS-350 TLS-350 FUEL FIL TE R MI D GRAD E FILL CONT AINMENT HI-SULFU R TIE DO WN CONCRETE PA DS ANOD E 13 UNDERG RO UND ST OR AG E TANKS WITH MEMBRANE LINE R R

L. ABOVEGROUND FUEL STORAGE TANK INSTALLATIONS Do a visual inspection of your aboveground tanks monthly, and keep records of the inspection. Vertical Installation Aboveground Fuel Storage Tanks 1. Check coating integrity 2. Check supports 3. Check secondary containment integrity 4. Inspect containment for liquid accumulation 5. Check drain valve for leak (must be lockable and secured when not in use) 6. Check vent lines to ensure caps are in place 7. Check for proper dimensions of containment volume Horizontal Installation Aboveground Fuel Storage Tank 1. Check tank coating integrity 2. Check vent line for installation of vent caps 3. Check secondary containment integrity 4. Check for liquid accumulation 5. Check containment for proper volume 6. Check drain valve for leak (must be lockable and secured when not in use) 7. Check fill containment Horizontal Installation Aboveground Fuel Storage Tank 1. Check roof integrity 2. Check tank coating integrity 3. Check vent line for installation of vent caps 4. Check secondary containment integrity 5. Check for liquid accumulation 6. Check containment for proper volume 14

M. SPECIFICATIONS FOR ABOVEGROUND STORAGE SECONDARY CONTAINMENT TANK CONTAINMENT CONTAINMENT PUMP # OF SADDLE SIZE AND # OF THICKNESS OF THICKNESS OF CAPACITY CAPACITY DIMENSIONS PLATFORM MOUNTS SKIDS SIDES BOTTOM IN GALLONS IN GALLONS 300 330 7 L x 4 W x 20 H 24 2 2-4 I-BEAM 3/16 3/16 550 605 9 L x 5 W x 24 H 24 2 2-4 I-BEAM 3/16 3/16 1,000 1,100 13 L x 5 W x 30 H 24 2 2-4 I-BEAM 3/16 3/16 2,000 2,200 14 L x 7 W x 36 H 24 2 2-6 I-BEAM 3/16 3/16 ` 3,000 3,300 20 Lx7.5 Wx36 H 36 3 3-6 I-BEAM 3/16 1/4 4,000 4,400 24 L x 8 W x 38 H 36 3 3-6 I-BEAM 1/4 1/4 5,000 5,500 20 L x 8 W x 48 H 36 3 3-6 I-BEAM 1/4 1/4 6,000 6,600 22 L x 8 W x 60 H 36 3 3-6 I-BEAM 1/4 1/4 8,000 8,800 24 Lx10 Wx60 H 36 3 3-8 I-BEAM 1/4 1/4 10,000 11,000 30 Lx10 Wx60 H 36 3 3-8 I-BEAM 1/4 1/4 12,000 13,200 35 Lx10 Wx60 H 36 3 3-8 I-BEAM 1/4 1/4 3-0 TYPICAL SECONDARY CONTAINMENT (Impervious Material) 3-0 TYPICAL SECONDARY CONTAINMENT TANK TANK TANK TANK TANK SUPPORT INSIDE TANK 3-0 TYPICAL INSIDE 3-0 3-0 TYPICAL INSIDE FILL SECONDARY CONTAINMENT FILL INSIDE TANK VENT TANK VENT TANK LENGTH INSIDE 3-0 TYPICAL LENGTH INSIDE TANK DRAIN VALVE BASE BASE DRAIN VALVE LENGTH INSIDE Note: All dimensions for secondary containment must be measured inside the secondary containment. Secondary containment must be made of impervious materials, be sealed and properly coated to prevent any fuel or sweating on the ground area around the secondary containment. All aboveground fuel storage tanks must identify (by name) the specific type of fuel that is being stored in each tank (e.g., diesel, gasoline, waste oil, etc.) 15

N. ABOVEGROUND EMERGENCY GENERATOR FUEL STORAGE TANK INSTALLATION 1. Aboveground Fuel Storage Tank 2. Underground Double Wall Fuel Line 3. Aboveground Double Wall Fuel Line (Alternative Installation) 4. Tank Fill Port 5. Liquid Level 6. Liquid Level Alarm* with Conduit 7 4 6 7. Vent with Pressure Vent Valve Cap 8. Monitoring Well (Conditional) 9. Generator Room 10. High Level Alarm 11. Liquid Alarm Unit *Note, if piping is installed inside of containment, a monitoring well installation is not required. 11 9 5 1 10 3 8 SECONDARY CONTAINMENT 2 Do a monthly visual inspection of your aboveground tanks and keep records of the inspection. The following pages are model forms that can be used to help with facility storage tank management. They are optional and are not required by rule. 16

O. FUEL DISPENSING SYSTEM AND ABOVEGROUND VISUAL INSPECTION CHECK SHEETS FUEL DISPENSING SYSTEM MONTHLY VISUAL INSPECTION CHECKLIST SUBMERSIBLE PUMP/PIPING DATE RESULTS REMARKS SECONDARY CONTAINMENT INTEGRITY CONTAINMENT COVER LIQUID SENSOR IN PLACE CORROSION PROTECTION ANODE WIRE IN PLACE SUBMERSIBLE PUMPS CONDITION PUMP & PIPING FREE FROM SOIL AMOUNT OF FUEL IN CONTAINMENT HYDROCARBON ODORS MODERATE OR STRONG MONITORING WELLS DATE RESULTS REMARKS MONITORING WELL CAPS IN PLACE WITH LOCK MONITORING WELL GROUTING INTEGRITY LIQUID ACCUMULATION REMOVAL MONITORING WELLS COVERS COLOR CODED 17

FUEL DISPENSING SYSTEM MONTHLY VISUAL INSPECTION CHECKLIST FILL AREAS DATE RESULTS REMARKS FILL CONTAINMENT LIQUID ACCUMULATION REMOVAL FILL PIPE DROP TUBE IN PLACE FILL CAPS & GASKETS IN PLACE FILL CAPS LOCKED FUEL OVERFLOW RELIEF VALVE IN PLACE DRY BREAK POPPET INTEGRITY DRY BREAK POPPET CAP & GASKET IN PLACE LIQUID ACCUMULATION REMOVAL FILL COVERS COLOR CODED OTHER COMMENTS: 18

FUEL DISPENSING SYSTEM MONTHLY VISUAL INSPECTION CHECKLIST DISPENSER DATE RESULTS REMARKS DISPENSER LINER INTEGRITY LIQUID ACCUMULATION REMOVAL LIQUID SENSOR CONNECTION SHEAR VALVE IN PLACE SHEAR VALVE BRACKET CONNECTION FUEL FILTER INTEGRITY PIPE FITTING LEAKS CORROSION PROTECTION ANODE CONNECTION VAPOR PUMPS OPERATING PRESSURE VENT VALVE IN PLACE OTHER COMMENTS: 19

UNDERGROUND STORAGE TANKS MONITORING WELL RECORD EACH WELL WILL BE CHECKED AND RECORDED - MONTHLY DATE WELL #1 ODORS PRODUCT DATE WELL #2 ODORS PRODUCT DATE WELL #3 ODORS PRODUCT DATE WELL #4 ODORS PRODUCT DATE WELL #5 ODORS PRODUCT DATE WELL #6 ODORS PRODUCT 20

CONTINUOUS AUTOMATIC LEAK DETECTION SYSTEM MONTHLY VISUAL INSPECTION - (IF APPLICABLE) MONTH OPERATING NORMAL ALARM DATE RESPONSE/COMMENTS JANUARY FEBRUARY MARCH APRIL MAY JUNE JULY AUGUST SEPTEMBER OCTOBER NOVEMBER DECEMBER ADDITIONAL COMMENTS: When there is a malfunction or an alarm, contact your equipment service department immediately for repairs or recalibration of the system. 21

FACILITY ADDRESS ABOVEGROUND STORAGE TANK I. D. # VISUAL INSPECTION CHECKLIST SECONDARY TANK PIPING DRAIN LIQUID STAINED SOIL CONTAINMENT ETERIOR ETERIOR VALVE ACCUMULATION AROUND INTEGRITY INTEGRITY INTEGRITY SECURE REMOVAL CONTAINMENT MONTH DATE AREA INITIALS JANUARY FEBRUARY MARCH APRIL MAY JUNE JULY AUGUST SEPTEMBER OCTOBER NOVEMBER DECEMBER OTHER COMMENTS: 22

Release Detection Response Level Description Definition of Release Detection Response Level (RDRL) (62-761 & 62-762) - is the point of measurement, calculation, observation, or level that is established for each individual release detection device or method at which an investigation must be initiated to determine if an incident, release, or discharge has occurred. Aboveground Storage Tanks Facility Name Address Emergency Contact Other Contact Release Detection Method: Monthly Visual Inspection of all regulated above ground storage tank system components, including the tank, piping, and containment. Response Level (Indicators): Excessive wear or other condition which may compromise the integrity of the system. Presence of product or stains on or around the exterior of the tank or piping. Presence of product or stains inside or outside the containment. Observation of leaks any part of the system. Investigation & Corrective Action: The presence of product and stains will be investigated to determine and repair the source. Any cracks, or other physical problems noted, will be corrected. Any leaks will be repaired. Reporting: An Incident Notification Form will be submitted if site conditions exist which indicate a discharge may have occurred. An Incident Notification Form will be submitted if more than 500 gallons or product is released into the containment. A Discharge Reporting Form will be filed with the Local Program if a discharge exceeding 25 gallons of product is discovered outside the containment. 23

Release Detection RESPONSE Levels Facility Name: Address: City: Zip Code: Emergency Contact: Operation Contact: Other: In accordance with 62-761.600(1)(b) and 62-762.601(1)(b), Florida Administrative Code (F.A.C.) The following Release Detection Response Level (RDRL) has been established for the checked method(s) of Release Detection: CHECK ALL THAT APPLY Release Detection Method Statistical Inventory Reconciliation (SIR) with a tank tightness test every three years RDRL One failed SIR report or two consecutive inconclusive SIR reports. A failed tank tightness test. Continuous Automatic Tank Gauge System Automatic Tank Gauge System with a tank tightness test every three years Vacuum Monitoring Electronic Monitoring of tank interstice Visual monitoring of tank interstice Annual Tank and Line Tightness Tests used with daily inventory reconciliation (available until 10 yrs. after last tank upgrade) Groundwater Monitoring Wells Vapor Monitoring Wells Manual Tank Gauging (Only valid for tanks up to 2000 gals) Electronic Monitoring of sumps and/or dispenser liners Visual Monitoring of sumps and/or dispenser liners Line Leak Detector Annual Line Tightness Test A failed 0.2 gph leak test report/printout. A failed 0.2 gph leak test report/printout. A failed tank tightness test. A sudden loss of vacuum or a 20% loss of the original vacuum. Alarm conditions, audible or visible. Presence of free product or water. Failed tank and/or line tightness test, unexplained water fluctuations exceeding one inch; significant loss or gain. Presence of free product or sheen. Discharge Report Form must be submitted within 24 hours. Vapor concentrations >500 ppm for gasoline, Vapor concentrations >50 ppm for diesel. Readings exceeding the standards described in 62-761.640 Table MTG, F.A.C. Alarm conditions, audible or visible. Water above the entrance of double-wall piping or presence of free product. Tripping/Activation of leak detector. Failed tightness test As required by 62.761.200(56) and 62-762.201(69), F.A.C., if the RDRL is measured or observed, we will initiate activities to determine if an incident, release, or discharge has occurred. If within 24 hours we cannot determine if a discharge occurred, an Incident Notification Form will be submitted. 24

UST System Inspection Checklist The Petroleum Equipment Institute (PEI) Tank Installation Committee has produced this checklist as a service to owners/operators of underground storage tanks (USTs). Items on the checklist should only be inspected by individuals knowledgeable of and familiar with UST systems. The frequency of inspections is the minimum standard recommended by the committee. Other factors affecting the frequency of inspection could include such things as monthly throughput, climatic conditions, applicable environmental rules and regulations, manufacturers' recommendations, experience with component performance, or other extenuating circumstances. Some fuel-dispensing system components must be inspected according to requirements established by environmental, fire safety, and/or other authorities having jurisdiction over UST systems. The specific inspection requirements can vary from jurisdiction to jurisdiction. Consult with the local authorities to determine applicable requirements. The Petroleum Equipment Institute hereby expressly disclaims any liability or responsibility for loss or damage resulting from the use of this checklist and for the violation of any federal, state, or municipal regulation with which this checklist may conflict. DISPENSER AREA Dispenser Sumps Piping Components Product Shear Valve Vapor Shear Valve Flex Connectors Clean and Empty - No water, product, debris. Sump Integrity - No leaks, cracks, bulges, holes. Leak Detection Sensor - Correct position and height. Test Leak Detector Sensor No abnormal appearance of piping or components. (Rust, discoloration, delamination, swelling, disintegration, etc.) Test boot (if applicable) pulled back so interstice is not blocked or obstructed. Properly secured and anchored. Installed at the proper level. No leaks. Test for proper operation. (Stage II Vapor Recovery Systems Only) Properly secured and anchored. Installed at the proper level. No leaks. Not in contact with other components, soil (without corrosion protection) or debris. KEY: D=Daily, M=Monthly, A=Annually D M A Date Initials LEAK DETECTION EQUIPMENT Automatic Tank Gauge Proper clearance between manhole lid and probe cap. ATG equipment operational and no alarms. Inspected per manufacturer recommendations. Interstitial Monitoring Monitoring ports properly identified. Monitoring equipment operational and no alarms. Inspected per manufacturer recommendations. Manual inspection if used for tank release detection. Manual Inventory Control Automatic Line Leak Detector Soil Vapor Monitoring Groundwater Monitoring Inspect measuring stick when gauging to be sure the increments are readable. Ensure bottom end has not been worn or cut off and stick is not warped. Product dispensers properly calibrated. Inventory reconciled. No leaks in the leak detector. No reduced flow, no alarms. Function tested. Covers clearly marked and secured Monitoring equipment operational. Inspected per manufacturer recommendations. Covers clearly marked and secured. Water present in wells. No evidence of product in wells. Monitoring equipment operational. Inspected per manufacturer recommendations. D M A Date Initials 25

TANK AREA Tanks Inspect for water. Observation Wells Tank Venting Equipment Spill Containment Manholes Containment Sump Manholes Containment Sump Sump Sensors Flex Connectors Stage I Vapor Recovery Manholes Two-Point (Dual- Point) Cover is tightly sealed, properly identified and secured. Cap is water tight and locked. Pressure/vacuum vent cap present (if required). Cover is in good condition and properly identified. Clean, Empty and Dry - No water, product, dirt, debris. Sump Integrity - No cracks, bulges, holes. Fill caps tightly sealed & gaskets inspected. Fill adapter tight on riser. Drop tubes in place and no obstructions. Cover is in good condition. Proper clearance between manhole lid and submersible pump. Containment sump lid and gasket in good condition. Clean, Empty and Dry - No water, product, dirt, debris. Sump Integrity - No cracks, bulges, holes. No abnormal appearance of piping. (Rust, discoloration, delamination, swelling, disintegration, etc.) Correct position and height, and operational. Test sensor. No leaks. Not in contact with other components, soil (without corrosion protection) or debris. Cover is in good condition and properly identified. Sump (if present) Integrity - No cracks, bulges, holes. Dry break poppet cap tightly sealed. Poppet seals tightly and moves freely when depressed. D M A Date Initials KEY: D=Daily, M=Monthly, A=Annually Overfill Protection Devices Ball Float Valves Verify in place. or Overflow Prevention Valves (Flapper Verify in place. Valves) or Overfill Alarms Functioning properly. (If present.) Corrosion Protection (If present.) Impressed Current Rectifier operating within normal limits. Cathodic Protection Proper operation verified by qualified person. or Galvanic Cathodic Proper operation verified by qualified person. Protection System Permission to photocopy this checklist and/or download without making any changes to the content is granted by the Petroleum Equipment Institute. 26

Daily UST System Inspection Checklist The Petroleum Equipment Institute (PEI) Tank Installation Committee has produced this checklist as a service to owners/operators of underground storage tanks (USTs). Items on the checklist should only be inspected by individuals knowledgeable of and familiar with UST systems. The frequency of inspections is the minimum standard recommended by the committee. Other factors affecting the frequency of inspection could include such things as monthly throughput, climatic conditions, applicable environmental rules and regulations, manufacturers' recommendations, experience with component performance, or other extenuating circumstances. Some fuel-dispensing system components must be inspected according to requirements established by environmental, fire safety, and/or other authorities having jurisdiction over UST systems. The specific inspection requirements can vary from jurisdiction to jurisdiction. Consult with the local authorities to determine applicable requirements. The Petroleum Equipment Institute hereby expressly disclaims any liability or responsibility for loss or damage resulting from the use of this checklist and for the violation of any federal, state, or municipal regulation with which this checklist may conflict. LEAK DETECTION EQUIPMENT Automatic Tank Gauge ATG equipment operational and no alarms. Interstitial Monitoring Monitoring equipment operational and no alarms. Daily Date Initials Manual Inventory Control Automatic Line Leak Detector Soil Vapor Monitoring Groundwater Monitoring Inspect measuring stick when gauging to be sure the increments are readable. Ensure bottom end has not been worn or cut off and stick is not warped. Inventory reconciled. No reduced flow, no alarms. Monitoring equipment operational. Monitoring equipment operational. Permission to photocopy this checklist and/or download without making any changes to the content is granted by the Petroleum Equipment Institute. 27

Monthly UST System Inspection Checklist The Petroleum Equipment Institute (PEI) Tank Installation Committee has produced this checklist as a service to owners/operators of underground storage tanks (USTs). Items on the checklist should only be inspected by individuals knowledgeable of and familiar with UST systems. The frequency of inspections is the minimum standard recommended by the committee. Other factors affecting the frequency of inspection could include such things as monthly throughput, climatic conditions, applicable environmental rules and regulations, manufacturers' recommendations, experience with component performance, or other extenuating circumstances. Some fuel-dispensing system components must be inspected according to requirements established by environmental, fire safety, and/or other authorities having jurisdiction over UST systems. The specific inspection requirements can vary from jurisdiction to jurisdiction. Consult with the local authorities to determine applicable requirements. The Petroleum Equipment Institute hereby expressly disclaims any liability or responsibility for loss or damage resulting from the use of this checklist and for the violation of any federal, state, or municipal regulation with which this checklist may conflict. DISPENSER AREA Dispenser Sumps Clean and Empty - No water, product, debris. Sump Integrity - No leaks, cracks, bulges, holes. Leak Detection Sensor - Correct position and height. Monthly Date Initials Piping Components Product Shear Valve Vapor Shear Valve Flex Connectors No abnormal appearance of piping or components. (Rust, discoloration, delamination, swelling, Test boot (if applicable) pulled back so interstice is not blocked or obstructed. Properly secured and anchored. Installed at the proper level. No leaks. (Stage II Vapor Recovery Systems Only) Properly secured and anchored. Installed at the proper level. No leaks. Not in contact with other components, soil (without corrosion protection) or debris. LEAK DETECTION EQUIPMENT Interstitial Monitoring Manual inspection if used for tank release detection. Monthly Date Initials Manual Inventory Control Automatic Line Leak Detector Soil Vapor Monitoring Groundwater Monitoring Inventory reconciled. No leaks in the leak detector. Covers clearly marked and secured Covers clearly marked and secured. Water present in wells. No evidence of product in wells. 28

TANK AREA Tanks Observation Wells Tank Venting Equipment Spill Containment Manholes Containment Sump Manholes Containment Sump Sump Sensors Flex Connectors Stage I Vapor Recovery Manholes Two-Point (Dual- Point) Inspect for water. Cover is tightly sealed, properly identified and secured. Cap is water tight and locked. Pressure/vacuum vent cap present (if required). Cover is in good condition and properly identified. Clean, Empty and Dry - No water, product, dirt, debris. Sump Integrity - No cracks, bulges, holes. Fill caps tightly sealed & gaskets inspected. Fill adapter tight on riser. Drop tubes in place and no obstructions. Cover is in good condition. Containment sump lid and gasket in good condition. Clean, Empty and Dry - No water, product, dirt, debris. Sump Integrity - No cracks, bulges, holes. No abnormal appearance of piping. (Rust, discoloration, delamination, swelling, disintegration, etc.) Correct position and height, and operational. No leaks. Not in contact with other components, soil (without corrosion protection) or debris. Cover is in good condition and properly identified. Sump (if present) Integrity - No cracks, bulges, holes. Dry break poppet cap tightly sealed. Poppet seals tightly and moves freely when depressed. Monthly Date Initials Corrosion Protection (If present.) Impressed Current Rectifier operating within normal limits. Cathodic Protection Permission to photocopy this checklist and/or download without making any changes to the content is granted by the Petroleum Equipment Institute. 29

Annual UST System Inspection Checklist The Petroleum Equipment Institute (PEI) Tank Installation Committee has produced this checklist as a service to owners/operators of underground storage tanks (USTs). Items on the checklist should only be inspected by individuals knowledgeable of and familiar with UST systems. The frequency of inspections is the minimum standard recommended by the committee. Other factors affecting the frequency of inspection could include such things as monthly throughput, climatic conditions, applicable environmental rules and regulations, manufacturers' recommendations, experience with component performance, or other extenuating circumstances. Some fuel-dispensing system components must be inspected according to requirements established by environmental, fire safety, and/or other authorities having jurisdiction over UST systems. The specific inspection requirements can vary from jurisdiction to jurisdiction. Consult with the local authorities to determine applicable requirements. The Petroleum Equipment Institute hereby expressly disclaims any liability or responsibility for loss or damage resulting from the use of this checklist and for the violation of any federal, state, or municipal regulation with which this checklist may conflict. DISPENSER AREA Dispenser Sumps Test Leak Detector Sensor Annual Date Initials Product Shear Valve Test for proper operation. LEAK DETECTION EQUIPMENT Automatic Tank Gauge Proper clearance between manhole lid and probe cap. Inspected per manufacturer recommendations. Interstitial Monitoring Monitoring ports properly identified. Inspected per manufacturer recommendations. Annual Date Initials Manual Inventory Control Automatic Line Leak Detector Soil Vapor Monitoring Groundwater Monitoring TANK AREA Containment Sump Sump Sensors Product dispensers properly calibrated. Function tested. Inspected per manufacturer recommendations. Inspected per manufacturer recommendations. Proper clearance between manhole lid and submersible pump. Test sensor. Annual Date Initials Overfill Protection Devices Ball Float Valves Verify in place. or Overflow Prevention Valves (Flapper Valves) or Overfill Alarms Verify in place. Functioning properly. (If present.) Corrosion Protection (If present.) Impressed Current Proper operation verified by qualified person. Cathodic Protection or Galvanic Cathodic Proper operation verified by qualified person. Protection System Permission to photocopy this checklist and/or download without making any changes to the content is granted by the Petroleum Equipment Institute. 30

NOTES 31

NOTES 32

This handbook is provided as a general guide. For specific regulation requirements refer to the underground and aboveground storage tank system rules (Chapter 62-761 and Chapter 62-762, Florida Administrative Code) which are located at the district and county offices, and at the storage tank program website (www.dep.state.fl.us/waste/categories/tanks/default.htm).

REMEMBER The State s economic engine is driven by the State s ecological engine, so help protect our ground and drinking water by properly maintaining your storage tank system. You make a difference working towards a cleaner environment. Thanks! We can succeed. This publication can be made available in large print, tape cassette or braille by request. This public document was promulgated at a cost of $0,000.00, or $0.000 per copy, to inform the public about storage tank facilities inspections. 2005 by the Florida Department of Environmental Protection