Specifications. Cat XQP150 Rental Generator Set. Prime 120 kw, 150 kva 50/60 Hz Switchable EU Stage IIIA. Prime kw (kva)

Similar documents
PRO Rental Product Range. PRO100-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

PRO Rental Product Range. PRO150-1 (Fuel Optimised) PRO150-2 (EUIIIa Compliant) KEY FEATURES. Alternator. Rental Ready Features

PRO Rental Product Range. PRO60-2 (R96 EUIIIa Equivalent) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR)

PRO Rental Product Range. PRO275-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

Prime. Turbocharged-Aftercooled (TA) Compression Ratio 16.7:1 Engine rpm Aftercooler Type

Compression Ratio 16.1:1 Engine rpm Aftercooler Type. Cat ADEM Control System Fuel See Fuel Specifications Table (page 4)

Specifications. Cat XQP500 Rental Generator Set. Prime 50 Hz 500 kva (400 kw) 50/60Hz Switchable Rating EU Stage IIIA

Prime. Turbocharged (T) Compression Ratio 18.23:1 Engine rpm Aftercooler Type

Specifications. Cat XQP500 Rental Generator Set. Prime 500 kva (400 kw) 50 Hz 50/60 Hz Switchable Rating

Prime. Turbocharged-Aftercooled (TA) Compression Ratio 16.8:1 Engine rpm Aftercooler Type

Generator Set Configurations Low Fuel Consumption, EU Stage IIIA Nonroad Emission Standards, China Nonroad III Emission Standards

DIESEL GENERATOR SET FEATURES

PRIME 920 ekw 1150 kva 50 Hz 1500 rpm 400 Volts

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 400 Volts

CONTINUOUS 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 415 Volts

Specifications. C13 Generator Set Electric Power

PRIME. 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

Standby 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

Generator Set Specifications 320 ekw (400 kva)

STANDBY 250 ekw 313 kva 60 Hz 1800 rpm 208 Volts

CMEC POWER GENERATION. PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET WHERE THE WORLD TURNS FOR POWER FEATURES

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 4160 Volts

Cat 3412 Diesel Generator Sets

Generator Set Specifications Rating (ekw) Rating (kva) Engine Specifications C32 ACERT TA, V-12, 4-stroke Water-cooled Diesel

PRIME 591 ekw 739 kva 60 Hz 1800 rpm 480 Volts

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1750 ekw 2188 kva 60 Hz 1800 rpm 440 Volts

MISSION CRITICAL 800 ekw 1000kVA 60 Hz 1800 rpm 480Volts

STANDBY 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

Standby. Speed rpm 60 Hz 480/277V 30 (38) 27 (35) Hz 208/120V 30 (38) 27 (35) Hz 240/120V 30 (30) 27 (27) 1800.

Cat C32 Diesel Generator Sets

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 650 ekw 812 kva 60 Hz 1800 rpm 480 Volts

CONTINUOUS 728 ekw 910 kva 50 Hz 1500 rpm 400 Volts

STANDBY 400 ekw 500 kva

PRIME 808 ekw 1010 kva 50 Hz 1500 rpm 415 Volts

STANDBY 350 ekw kva 60 Hz 1800 rpm 480 Volts

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 415 Volts

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 415 Volts

Cat 3516B Diesel Generator Sets

STANDBY 600 ekw 750 kva 60 Hz 1800 rpm 220 Volts

3412C Generator Set Electric Power. Specifications. Benefits and Features

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

PRIME 225 ekw 281 kva

Engine Specifications 3512C HD ATAAC, V-12, 4-Stroke Water-Cooled Diesel Compression Ratio 14.7:1 Aspiration

PRIME 910 ekw 1138 kva 60 Hz 1800 rpm 480 Volts

STANDBY 880 ekw 1100 kva 50 Hz 1500 rpm 400 Volts

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 400 Volts

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

Cat 3512 Diesel Generator Sets

Cat XQP1100 Rental Generator Set. Specifications

RENTAL XQ400 SOUND ATTENUATED. 50/60 Hz FEATURES

Cat 3512B Diesel Generator Sets

Cat 3516B Diesel Generator Sets

Cat C Diesel Generator Sets

Cat 3516B Diesel Generator Sets

Cat 3516B Diesel Generator Sets

Cat 3512B Diesel Generator Sets

Cat 3512B Diesel Generator Sets

Cat 3512 Diesel Generator Sets

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

PRIME 508 ekw 635 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1000 ekw 1250 kva 50 Hz 1500 rpm 400 Volts

Hydraulic electronic unit injection

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

PRIME 725 ekw 906 kva 60 Hz 1800 rpm 480 Volts

Engine Specifications C32 ACERT TA, V-12, 4-stroke Water-cooled Diesel. Compression Ratio 15.0:1 Turbocharged Aftercooled.

220 to Volts. Generator Set Configurations U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)

Generator Set Specifications 480 ekw 600 KVA

Cat C Diesel Generator Sets

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm Volts

220 to Volts or 1800 RPM

STANDBY 2000 ekw 2500 kva 60 Hz 1800 rpm Volts

220 to Volts or 1800 RPM

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

C13. STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

STANDBY 2000 ekw 2500 kva 50 Hz 1500 rpm Volts

CONTINUOUS 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

Continuous, Prime, Standby, Mission Critical

STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 600 Volts

Voltage 220 to or 1800 RPM

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 415 Volts

Mission Critical Standby 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

STANDBY 300 ekw 375 kva 60 Hz 1800 rpm 480 Volts

STANDBY. 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET FEATURES

PRIME 1360 ekw 1700 kva 50 Hz 1500 rpm 400 Volts

Specifications. 3406C Generator Set Electric Power

DIESEL FEATURES GENERATOR SET

STANDBY 600 ekw 750 kva 50 Hz 1500 rpm 400 Volts

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

Cat C32 Diesel Generator Sets

CONTINUOUS 1230 ekw 1538 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1500 ekw 1875 kva 50 Hz 1500 rpm 400 Volts

PRIME 2260 ekw 2825 kva 50 Hz 1500 rpm Volts

STANDBY 700 ekw 875 kva 60 Hz 1800 rpm 600 Volts

STANDBY 900 ekw 1125 kva 60 Hz 1800 rpm 480 Volts

MISSION CRITICAL STANDBY. 50 Hz 1500 rpm Volts DIESEL GENERATOR SET FEATURES

Transcription:

Prime 120 kw, 150 kva 50/60 Hz Switchable EU Stage IIIA Image shown may not refl ect actual confi guration Specifications Frequency 50 Hz 60 Hz Voltage Prime kw (kva) Speed rpm 380/220 V 120 (150) 1500 400/230 V 120 (150) 1500 415/240 V 120 (150) 1500 380/220 V 128 (160) 1800 440/254 V 148 (185) 1800 480/277 V 148 (185) 1800 220/127 V 148 (185) 1800 240/138 V 148 (185) 1800 Configuration Cat C7.1 Diesel Engine Metric Imperial (English) I-6, 4-Stroke-Cycle Water Cooled Diesel EATAAC (TAG3) Bore 105 mm 4.13 in Stroke 135 mm 5.31 in Displacement 7.01 L 427 in 3 Aspiration Turbocharged-Aftercooled Compression Ratio 16.8:1 Engine rpm 1500-1800 Aftercooler Type Turbocharger Fuel System Governor Type ATAAC Single Electronic CRIN2 A4:E2 LEHE1014-00 Page 1 of 6

Benefits & Features Fuel/Emissions Strategy Cat C7.1 high performance diesel engine Meets Stage IIIA emissions standards Single-source Supplier Factory designed and fully prototype tested with certified torsional vibration analysis available ISO 9001:2000 compliant facility Cat C7.1 Diesel Engine Four-stroke diesel engine combines consistent performance and excellent fuel economy with minimum weight ECM electronic engine control Cat EMCP 4.2B Control Panel Fully featured power metering, protective relaying, and engine/generator control and monitoring Simple user-friendly interface and navigation Automatic set-point adjustment integrated with voltage and frequency changes Cat LC3100 Generator Designed to match performance and output characteristics of Cat diesel engines Coastal insulation protection Self (shunt) excitation Integrated Voltage Regulator (IVR) Three-phase sensing Adjustable volts-per-hertz regulation Provides precise control, excellent block loading, and constant voltage in the normal operating range Enclosure Galvanized sheet steel construction Two-coat polyester powder-coated finish Six lockable (padlock/keylock) access doors Safety glass control panel viewing window with key lock or padlockable access doors Fuel fill and battery can only be reached through lockable access doors Reduced Environmental Impact Meets Stage IIIA emissions standards Dual wall base tank with 110% spill containment Bund level alarm High noise reduction performance 92 dba; sound power 50 Hz, exceeding EU machinery directive limits Rental-ready Features Forklift pockets Integrated heavy-duty drag bar with robust skid plate Fully certified single-point lift Coolant and oil drains piped to baseframe EMC certified Fully certified spark arresting silencer 50/60 Hz frequency switch via terminal link Optimized cable entry for easy hook-up Sound isolated control panel with integrated power distribution access Robust hook-up point for lugged cable connection AC protected by limit switch on distribution door Available Options CE socket box with integrated MCB and RCBO protection Clipsal socket box with integrated MCB and RCBO protection Anti-condensation heater 110 or 230 VAC Coolant heater 110 or 230 VAC 12V battery charger Permanent Magnet Generator (PMG) Earth leakage CE labeling Lube oil sump pump UL/CSA listed 120V, 20 amp battery charger, shock mounted and enclosed in dust-proof housing LEHE1014-00 Page 2 of 6

Standard Equipment Air Inlet Air cleaner, two stage cyclonic/paper with dust cup and service indicator Turbocharger and air-to-air aftercooler Alternator LC3114J frame 3-phase, random wound, 12 lead design, self excited, 2/3 pitch Coastal Insulation protection Charging System Charging alternator 12V, heavy duty with integral regulator and belt guards Control Panel EMCP 4.2B generator set mounted digital controller 50/60 Hz frequency switch via terminal link Panel mounted emergency stop switch IVR with EM10 excitation module Automatic set-point adjustment integrated with voltage and frequency changes Fully featured power metering, protective relaying and engine/generator control and monitoring Cooling System Package-mounted radiator with high ambient performance Pusher fan with guards Coolant drain line with internal brass ball control valve piped to base-frame Low coolant level shutdown 50% coolant antifreeze with corrosion inhibitor Distribution System Robust steel enclosure, separate hinged, lockable door with rust-resistant pinned hinges Main circuit breaker 4-pole, 250A with 24V DC shunt trip wired to distribution door safety switch Two-wire remote start/stop terminals and 120-240 VAC auxiliary power connection for rapid starting Enclosure Sound attenuating, galvanized sheet metal enclosure with exceptional noise reduction performance External emergency stop switch on enclosure Modular panel construction with a welded roof design Interior walls, ceilings, and ducts insulated with precision-cut noise insulating materials Sealed quarter-turn compression door latches with key and padlock capabilities Front and rear access provided through hinged doors External single-point lifting Enclosure is powder-coated white with Cat Rental Power decals Engine Cat C7.1 heavy-duty diesel engine Full electronic engine control Exhaust System Integrated spark arresting silencer with flexible connectors, in separate compartment Fuel System 156 gal (590 L) double-wall fuel tank, 24-hour runtime @ 75% prime rating, internal fuel fill Engine-mounted primary fuel filter (10 micron) with integral water separator and water-in-fuel sensor Off-engine-mounted Racor fuel water separator (30 micron) Manual pushbutton priming pump Auxiliary connections for customer-supplied fuel transfer with 3-way fuel transfer system, internally mounted within the bunded area Mechanical fuel gauge Electronic fuel gauge with control panel display. high and low level fuel warning/shutdown. Configurable bund level sensor, low level warning and high level warning/shutdown LEHE1014-00 Page 3 of 6

Standard Equipment (continued) Generator LC3114J frame, three-phase, random wound, 12-lead design, self-excited, 2/3 pitch Coastal insulation protection 120 or 230 VAC anti-condensation heater available Lube System On-engine primary and secondary oil filters, filler, and dipstick Open crankcase breather with a fumes disposal container, drain located on side of base frame Oil drain piped to edge of base frame with internally mounted ball valve. 500-hour oil change intervals Mounting System Generator set soft-mounted using captive vibration mounts Heavy-duty steel base frame contains integral fuel tank Provides 110% spill containment of all engine fluids Forklift pockets and heavy-duty drag bar with skid plates Starting System Single electric starting motor, 12V 2x 12V 950 CCA maintenance-free batteries (wired in parallel), with single-pole battery isolator switch 120/240V single-phase jacket water heater with thermostat and shut-off valves General Factory testing of standard generator set Full manufacturer s warranty, O&M manuals LEHE1014-00 Page 4 of 6

Technical Data Cat Generator Frame size LC3114J Pitch 2/3 No. of poles 4 Excitation Static regulated, brushless, self-excited Number of bearings Single bearing, close coupled Insulation Class H Temperature rise 125/40 C Enclosure Drip proof IP23 Overspeed capability % of rated 25% Voltage regulator 3-phase sensing with adjustable volts-per-hertz Voltage regulation Less than ± 0.5% Wave form deviation Telephone Infl uence Factor (TIF) Less than 2% Harmonic Distortion (THD) Less than 2% Cat Generator Set Units 50 Hz Prime 60 Hz Prime P4390D P4390C Power Rating kw (kva) 120 (150) 145 (181) Performance Specification Lubricating System Oil pan capacity L (gal) 12.4 (3.3) 12.4 (3.3) Fuel System Fuel consumption 100% Load 75% Load 50% Load Fuel tank capacity Running time @ 75% rating Cooling System Ambient capability Engine & radiator coolant capacity Engine coolant capacity L/hr (gal/hr) L/hr (gal/hr) L/hr (gal/hr) L (gal) Hr C ( F) L (gal) L (gal) 37.5 (9.9) 29.6 (7.8) 20.3 (5.4) 590 (155.9) 24 46 (115) 22 (5.8) 9.5 (2.5) 42.3 (11.2) 34.7 (9.2) 23.8 (6.3) 590 (155.9) 24 46 (115) 22 (5.8) 9.5 (2.5) Air Requirements Combustion air fl ow m 3 /min (cfm) 11.4 (402.6) 14.9 (525.5) Exhaust System Exhaust fl ow at rated dry exhaust Exhaust temperature at rated kw Noise Rating (with enclosure)* Sound Power* @ 1 meter @ 100% load @ 7 meters @ 100% load @ 1 meters @ 75% load @ 7 meters @ 75% load *Guaranteed sound power as per 2000/14/EC m 3 /min (cfm) C ( F) 26.4 (932) 491 (915.8) 91 77 65 77 64 30.6 (1079) 440 (824) 95 81 68 81 67 LEHE1014-00 Page 5 of 6

Technical Data (continued) Dimensions Length mm (in) Width mm (in) Height mm (in) Generator Set 3520 (138.6) 1120 (44.1) 2226 (87.6) Weight Weight kg (lb) Lube Oil & Coolant Empty Fuel Tank 2547 (5615) Full Fuel Tank 3124 (6887) Rating Definitions and Conditions Designed to Meet Specifications: ISO 8528, EN 12601, EN 60204-1, ISO 3046, IEC 60034. Meets the Following EU Directives (when the CE option is selected): 2006/42/EC, 2006/95/EC, 2004/108/EC, 2000/14/EC. Ratings are based on SAE J1349 standard conditions. These ratings also apply at ISO3046 standard conditions. Prime Applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation on the annual hours of operation and the generator can supply 10% overload power. Fuel rates are based on fuel oil of 35º API [16ºC (60ºF)] gravity having an LHV of 42 780 kj/kg (18,390 Btu/lb) when used at 29ºC (85ºF) and weighing 838.9 g/liter (7.001 lbs/u.s. gal). Additional ratings may be available for specific customer requirements, contact your Cat representative for details. For information regarding low sulfur fuel and biodiesel capability, please consult your Cat dealer. www.cat.com/rentalpower 2016 Caterpillar All rights reserved. Materials and specifications are subject to change without notice. The International System of Units (SI) is used in this publication. LEHE1014-00 (2-16) CAT, CATERPILLAR, their respective logos, Caterpillar Yellow, the Power Edge trade dress as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.