INTELEPOWER CXS SWITCHING SYSTEMS

Similar documents
INTELEPOWER CX COMMUNICATIONS SYSTEMS

CENTURY YUASA - STANDBY OVERVIEW

MP Access Charger.

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

$& '& 3RZHU 6XSSOLHV '& '& &RQYHUWHUV %DWWHU\ &KDUJHUV

AME. Rectifier - Battery charger. Industrial applications: Key features:

Aurora Single Phase Emergency Lighting Inverters

PSU EN54-4 Power Supplies

Industrial Chargers and

Power Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

Est FlexiPower Mini UPS FPX Mini kVA

Offshore and process industry Safety and Automation Systems (SAS) Marine Communication systems onboard ships. Railway & Metro infrastructure

PowerPro three phase UPS technical data

QUALITY ASSURANCE & DOCUMENTATION

596 Rectifier Retrofit

DPA 250 S4 (50 kw 1,500 kw) The most energy-lean UPS on the market MODULAR THREE-PHASE UPS SYSTEMS. The most energy-lean UPS on the market

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

BATTERY TESTING SOLUTIONS

Galaxy VM. From 160 kva to 1000 kva, 160 kva or 200 kva modular approach. Three-phase power protection

Galaxy VM. From 160 kva to 1000 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity. schneider-electric.

Features and Benefits

Liebert Hipulse E The High-ECO-Availability UPS. AC Power Systems

Keor MOD THREE-PHASE MODULAR UPS. up to 250 kw THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL INFRASTRUCTURES

Uninterruptible Power Supplies

W Datasheet: UPS AVARA Modular kVA (1-8 x 15kvA)

Technical Data Sheets

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

Schneider Electric PV Skid. Optimized solar power conversion system tailored to enhance any North American PV power plant

Reference Number PDS 18 - (RIC Standard: EP SP)

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

Galaxy VM. From 160 kva to 1000 kva Three-phase power protection. apc.com/products

Enterprise Power Protection

Technical Data Sheets

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Technical Data Sheets

Food power. ABB s rugged UPS PowerLine DPA ensures food and beverage production facilities keep running

UPS5000-E (25-75 kva) Series

Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software

60 to 160 kva.

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

PowerValue 11/31 T kva

Modular UPS «AGIL» Stay on! Changing the rules for critical business continuity :

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

Standard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Each pump shall be equipped with carbon/graphite vanes. A vacuum relief valve shall be incorporated into the design of the pump.

Series 120/120VAC Universal Tower/Rack Mount

MGE Galaxy 5500 Marine

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

The pumps shall be Oil Free and Variable speed controlled by Pressure Transducer, PLC and inverter.

The pumps shall be Oil Free and Variable speed controlled by Pressure Transducer, PLC and inverter.

Exceeding the standards with MNS

S2000 PRODUCT RANGE. Ultra compact

AMS. Rectifier - Battery charger. Industrial applications: Key features: VRLA batteries with output voltage from 24, 48, 110, 220 Vdc up to 30A

Low and medium voltage service. Power Care Customer Support Agreements

Symmetra PX 250/500. Scalable from 100 kva kw to 500 kw, parallel capable up to 2,000 kw

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Power Conversion System The Best Technology for your photovoltaic and storage system

On-line, Single Phase, Double Conversion UPS

HIGH POWER RECTIFIER SYSTEMS

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

ABB in primary aluminium From mine to market

Emergi-Lite Experts in central power supply systems

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen.

magellan commercial UPS solutions Magellan Power Modular - Flexible UPS

Illuminator Series CR NEMA 3R

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Phase Modular Finally the benefits of Modular ups are for all

TRIMOD HE UPS. MODULAR THREE-PHASE UPS from 10 to 80 kw THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

ABB central inverters ULTRA-750/1100/ kW to 1560kW

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

TECHNICAL SPECIFICATIONS FOR. 3/5/6/8/10 kva Single phase in/out Single or parallel UNINTERRUPTIBLE POWER SUPPLY SYSTEMS

Technical Data Sheets

Three-phase UPS system. DPA UPScale ST kw Best-in-class modular UPS for maximum availability

True double-conversion online single-phase UPS. PowerValue 11 RT 1 10 kva Single-phase UPS for critical applications

Liebert. FP 50Z kva

SERIES Pulse and 12 Pulse DC Power Supplies for Electrocoating and Industrial DC Powered Systems MODELS 506 & 5012

Three Phase UPS Systems Range: 10 to 500kVA

Symmetra PX. Industry-leading efficiency, availability, and performance for small, medium, and large data centers and mission critical environments

G V Series UNINTERRUPTIBLE POWER SYSTEMS. Phone: Fax: Web:

Liebert GXT4. Intelligent, Reliable UPS Protection 5kVA - 10kVA

off-grid Solutions Security of supply Basics: Off-grid energy supply

3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems:

Technical Data Sheets

UPS Multi Power 1-28 x 42 kw up to 1MW

Equipment Strategy for Stand By Diesel Generators Strategy

Technical Data Sheets

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

Three-phase UPS system DPA UPScale ST kw The modular UPS designed for lowand medium-power applications

Supply, testing, installation and commissioning of 5 ky A UPS system as per the following specification:

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Transcription:

INTELEPOWER CXS SWITCHING SYSTEMS

INTELEPOWER CXS SWITCHING SYSTEMS Intelepower DC UPS - CXS Range Designed For Switching The demands for quality power in switching applications are placing new demands on DC Uninterruptible Power Supplies (UPS). Power quality and reliability are integral to ensuring the availability of many of the systems which now run critical operations on a day-to-day basis. These continuing changes in technology have seen businesses evaluate the costs associated with downtime due to power outages, making the need for uninterrupted power an essential component of a business infrastructure. Century Yuasa Intelepower Industrial DC power systems are designed to provide absolute reliability where quality power and power equipment is mandatory for overall integrity of operations. Guaranteeing power during mains black-out or brown-out conditions, each system is assembled with Yuasa industrial VRLA batteries. Through close collaboration with international engineers and local customers, Century Yuasa has developed a range of DC UPS systems under the Intelepower brand which is synonymous with reliability, integrity and value for money. The Intelepower CXS Switching systems have the flexibility to satisfy the most stringent specifications. Intelepower is suitable for: Each system is network ready, with integrated SNMP and SCADA technology allowing operators to access system performance in real time from a remote location, reducing costs associated with servicing. Specialised engineering personnel can design, install, and commission complete systems as well as offer specialised consultative services to manage one-off or a complete network of UPS equipment. All standard Intelepower CXS Switching systems are designed to all relevant Australian Standards, to provide the reliability of power for essential operations. Century Yuasa has the expertise and resources to ensure that work is carried out effectively and efficiently to internationally bench marked quality standards, ISO 9001:2000. Regardless of the size of your switching network, an Intelepower system can be designed to provide one of the most reliable uninterruptible power sources. Emergency Power Industrial Switch Tripping Intelepower Industrial DC Systems can be customised for your specific application and power requirements. Using a modular design philosophy, Intelepower systems are flexible enough to cater for expansion of components and ease of replacement. This is achieved through the use of switch mode rectifier technology with hot-swappable capabilities. This provides readily expandable power or N+1 redundancy options with minimal cost increases, while offering reduced MTTR (Mean Time To Repair).

Key Design Elements That Help You Duty of care reduction of risk Not only does Intelepower look good, but Century Yuasa also ensures full compliance with relevant safety standards and regulations, so that your most precious assets, your staff, are safe. The unique features of the Intelepower battery segregation means that your personnel are protected from unlikely hazardous events. Power that you can rely on Only the most reliable components that are available are used, resulting in the best MTBF (Mean Time between Failures) possible. This can be further increased by the addition of a redundant rectifier (recommended) Low maintenance costs The high reliability of Intelepower results in low maintenance costs. Although the batteries used are Yuasa and will result in a long life, that life is still finite so Century Yuasa recommends six monthly checks in order to trend the batteries and predict future performance. Because of the technology used, these checks are able to be done in normal hours without disruption to supply. The modular approach to design allows for low cost replacement of electronic components, normally without any disruption to supply. Low running costs The high efficiency of the latest switch mode rectifiers, all done with high efficiency power conversion switch mode technology, means that the lowest possible electricity usage is achieved. Low upgrade costs What happens when you add equipment that wasn t planned? Usually this requires the purchase of new power equipment. However with the modular design of Intelepower, it is usually possible to upgrade at minimal cost, especially if this is allowed for when selecting. Easy to purchase and integrate into customer premises Intelepower is made and stocked in Australia and usually comes complete with delivery, installation and commissioning. All this is done transparently and efficiently by the Century Yuasa expert team. All you need to do is supply AC power close by. The Intelepower equipment meets all relevant International specifications for EMC and other types of electrical interference. No power down time Intelepower DC UPS are intended to be powered continuously with no off period, unless the AC power feeding the equipment is off longer than the designed autonomy time. In most cases work such as maintenance and upgrades can be completed without any power down, especially if this work is carried out by Century Yuasa s expert Technicians. Monitoring Monitoring is standard on Intelepower systems which are network ready with integrated SNMP and web page access.

INTELEPOWER CXS SWITCHING SYSTEMS CXS48 Systems CXS48 Types 1 to 4 Electrical Input VAC Input 240VAC (176-320VAC) 1 Phase or 415VAC 3 Phase +N+E Max Input Current (A) 4.6A @ 240VAC (per rectifier) Power Factor >0.99 Input Frequency 45-66Hz Electrical Output Rectifier Type Intelepower CX 1kW Modular Switch Mode Rectifier System Nominal VDC 48VDC Efficiency >91% (100% load + recharge) Load Regulation (Static) <±0.5% Cooling Natural convection Electrical Other Distribution Battery Isolation Monitoring and Control Alarms Mechanical Cabinet Configuration Cabinet Colour Dimensions (mm) Double Pole MCB Isolation per string LCD touchscreen display supervision of AC Mains, rectifiers, battery, breakers and earth fault. Intelepower CXCM is network ready with integrated SNMP and web page access. Reports AC mains failure, earth fault alarm and customer definable urgent and non-urgent alarms. 45RU Cabinet N35 2150H x 600W x 600D Environmental System Rated Temperature 25ºC Operating Temperature Range * 0ºC to 45ºC Operating Humidity Range Elevation 0 to 95% RH non-condensing 0 to 2000m Design Considerations AS 3011 Part 2, AS 2676 Part 2, AS 4044, AS 3000, IEEE 485 * Battery performance is rated to 25ºC Further information can be obtained by contacting Century Yuasa Batteries

Random Momentary Loads The Intelepower CXS48 and CXS110 are standard ranges of DC Auxiliary systems for high current industrial switching. With a nominal voltage of 48VDC or 110VDC these systems are configured for 4-hour, 8-hour, 12-hour and 24-hour back-up periods as well as catering for a single random momentary load (<1 minute) (Figure 1) Power (P) Continuous Load (Watts) Momentary Load (Watts / Amperes) Random <1 minute Figure 1. Time (t) Engineered to provide a complete and compliant offering, these systems use modular technology to improve redundancy options and reduce down time. The battery is sized to IEEE 485 for a single standing load and a randomly occurring momentary load for 1-minute, using k-factors. The battery is sized at 25 C with an aging factor for the battery to ensure the battery s performance to specification at end of the system s design life. An additional design margin has been included to cover switching operations to a minimum operating temperature of 20 C. Based on 54-cells and with a float voltage of >120VDC classifies the Intelepower CXS110 system as Low Voltage under AS3000. With this in mind, care has been taken to ensure compliance to all relevant standards and additional special features to reduce risks associated with installation and maintenance. All systems include clear and durable engraved labeling for easy identification of hazards and electrical ratings of components. CXS48 45RU Cabinet As the Intelepower CXS48 and CXS110 ranges are designed as floating systems, an earth fault detection device is supplied standard which continuously and actively monitors leakage to earth. The termination of earthing wiring within the cabinet is achieved through a common earthing bar, which includes a provision for termination of field cable shields. The customer connection panel, located at the front, allows ease of termination of DC loads, AC input and alarming take-off s through dedicated terminal blocks.

INTELEPOWER CXS SWITCHING SYSTEMS CXS110 Systems Electrical Input VAC Input CXS110 Types 1 to 2 CXS110 Types 3 to 4 240VAC (176-320VAC) 1 Phase or 415VAC 3 Phase +N+E 240VAC (176-320VAC) 1 Phase or 415VAC 3 Phase +N+E Max Input Current (A) 5A @ 240VAC (per rectifier) 5A @ 240VAC (per rectifier) Power Factor >0.99 (100% load) >0.99 (100% load) Input Frequency 45-66Hz 45-66Hz Electrical Output Rectifier Type Intelepower CX 1.1kW Modular Switch Mode Rectifier Intelepower CX 1.1kW Modular Switch Mode Rectifier System Nominal VDC 110VDC 110VDC Efficiency >93% (100% load) >93% (100% load + recharge) Load Regulation (Static) <±0.5% <±0.5% Cooling Natural Convection Natural Convection Electrical Other Distribution Double Pole MCB Double Pole MCB Battery Isolation Isolation per string Isolation per string Monitoring and Control Alarms LCD touchscreen display supervision of AC Mains, rectifiers, battery, breakers and earth fault. Intelepower CXCR is network ready with integrated SNMP and web page access. Reports AC mains failure, earth fault alarm and customer definable urgent and non-urgent alarms. LCD touchscreen display supervision of AC Mains, rectifiers, battery, breakers and earth fault. Intelepower CXCR is network ready with integrated SNMP and web page access. Reports AC mains failure, earth fault alarm and customer definable urgent and non-urgent alarms. Mechanical Cabinet Configuration 45RU Cabinet 45RU Power Cabinet and 27RU Battery Cabinet Cabinet Colour N35 N35 Dimensions (mm) 2150H x 600W x 600D 2150H x 1200W x 600D Environmental System Rated Temperature 25ºC 25ºC Operating Temperature Range * 0ºC to 45ºC 0ºC to 45ºC Operating Humidity Range 0 to 95% RH non-condensing 0 to 95% RH non-condensing Elevation 0 to 2000m 0 to 2000m Design Considerations AS 3011 Part 2, AS 2676 Part 2, AS 4044, AS 3000, IEEE 485 * Battery performance is rated to 25ºC Further information can be obtained by contacting Century Yuasa Batteries. AS 3011 Part 2, AS 2676 Part 2, AS 4044, AS 3000, IEEE 485

CXS110 45RU Cabinet CXS110 45RU Power Cabinet and 27RU Battery Cabinet Tailor Your System with Additional Choices Cabinet Designs indoor and outdoor Other cabinet designs are available to order, or in some cases power equipment can be installed in the customer s racks. However it is important to remember two things. Firstly, that we all have Duty of Care and need to maintain compliance with the standards and regulations. Secondly, that the battery size is dependant on the time that you wish the equipment to continue to work during a power failure. Input voltage Most Intelepower DC UPS can be supplied from either single phase or 3-phase depending on the total load to be supplied. Customer defined alarms The flexible alarm outputs can be configured to your special requirements. Please ask for your Intelepower DC UPS to be pre-programmed to suit. Customer installation This can be done if your installation staff have the correct training and expertise; however it is best left to Century Yuasa Technicians. If for some reason this is impractical, then we would recommend training and commissioning be carried out by Century Yuasa. Surge and lightning protection All Intelepower CX Rectifier Modules include surge and lightning protection as standard. For high lightning prone areas, Century Yuasa can advise on additional protection requirements, which can be added to the Intelepower DC UPS in many cases.

Disclaimer This paper contains information obtained through personal knowledge, professional knowledge, experience and due diligence of research in relation to the nominated topic. It is expected that the information so contained shall be used as an indication of the issues to be considered in relation to the given topic, and that the person(s) seeking to undertake works in relation to this or associated matters are advised to seek professional advice from their Century Yuasa Batteries Pty Ltd. representative through one of the contacts listed below and in other literature. Neither Century Yuasa Batteries Pty Ltd., nor the author shall be held directly or indirectly liable, in anyway whatsoever for any subsequent usage or interpretation of the information so contained in this article and where used outside the scope of its stated purpose. Further information can be obtained by contacting your nearest Century Yuasa Batteries Pty Ltd representative. Head Office 37 65 Cobalt Street Carole Park Queensland 4300 ph +61 7 3361 6161 fax +61 7 3361 6366 www.centuryyuasa.com.au www.intelepower.com.au Enquiries within Australia ph 1300 364 877 fax 1300 364 329 Enquiries within New Zealand ph 0800 236 8879 fax +64 9 978 6677 An affiliated business of the GS Yuasa Corporation, CenturyYuasa has an 80-year history of supplying a range of stored energy solutions to the Australian market. An established network of sales and distribution offices throughout Australia and New Zealand has seen the business gain the trust and respect from its customers by focusing on quality products and exceptional customer service. The portfolio within CenturyYuasa includes a wide range of stored energy products and services, as well as identifiable brands and unique technologies for automotive, materials handling and standby power applications. Directly maintaining and operating three manufacturing centres in Australia and employing some 650 people, CenturyYuasa continues to be Australia s enduring manufacturer of stored energy products. IP303-788