Lever Flush Cistern Fittings rcade close coupled cistern RC5C ll WC s come with a /6 litre flush as standard which can be reduced to a.5/4.5 litre flush for the slimline cisterns On the Close Coupled WC you must press the lever down lightly for the 6 litre flush and lightly lift the lever for the litre flush litres 6 litres Please note that it is imperative that there are no loops or kinks in the yellow tube when installed and that the lever is not operated with excessive force as this will damage the cable inside the tube that lifts and lowers the flush valve causing the flush to fail beyond repair - 5
Lever Flush Cistern Fittings rcade close coupled cistern RC5C Parts supplied: Please read these instructions carefully to avoid damage Bolt Doughnut Fixing Nut to the valves, and to ensure correct installation. Do not use bleach or bleach based cleaning products in x the cistern, as these will cause damage to the seals. We cannot be held responsible or liable for any failure which results from the use of bleach based products. Water temperature range +C to +45C. Inlet Valve Lever Plastic Cone Flush Cone Water pressure 0. to 8 bar. : Inlet Valve scale and adjustment settings : Major water level adjustment 6L/L 4.5L/.6L 0 0 Exposed "" steps "0" scale Exposed "" steps "" scale Note: The inlet valve is preset for 6L full flush and L half flush. The above diagram indicates the correct setting for 6L/4.5L full flush and L/.6L half flush. For adjustment method, please refer to the right diagram. Take off locker Loosen the inlet body by turning slightly anti-clockwise, djust it up or down to correct position and tighten clockwise. Re-insert the locker - 5
B: Minor water level adjustment NOTE: djustment Rod Stop Float Stop Float djustment Rod Stop Float Float cup Stop Float Slide the locker to "unlock" position, Move the stop float up/down. To decrease the water level use a screw driver to adjust the level of the Stop Float (as shown).the float should be lowered. To increase the water level use a screw driver to adjust the level of the Stop Float (as shown).the float should be raised. Ensure the top surface of Stop Float is in line with the top surface of the Float Cup. Slide the locker to the "locked" position : Inlet Valve installation : Filter cleaning (Please clean periodically) Cistern Inlet Valve Inlet valve Plastic Nut 4: Inlet Valve trouble shooting Problem Incorrect water level Inlet Valve does not work Tighten the nut after having adjusted the lnlet valve calibration as per page &. Reason Incorrect adjustment. Water supply is closed. The filter is blocked. Filter Pull out the filter from the Inlet valve. Clean the filter. Solution djust the Water. level correctly as per page &. Open the water supply Filter Clean by rinsing the filter. Insert the filter back into the Inlet valve. Leakage The Stop Float has been over adjusted beyond its operational range. The Inlet Valve fixing nut has not been tightened. Reconnect the djustment Rod, and adjust the water level as per on page. Tighten the nut. - 5
: scale and adjustment setting Installation nd Problem Solving Note: The is preset for 6L full flush and L half flush. The diagram below indicates the correct setting for 6L full flush and L half flush. The diagram B below indicates the correct setting for 4.5L full flush and.6l half flush. B Half Flush Float : should be set on the.5 mark Full Flush djustor : should be set on the.5 mark Half Flush djustor : should be set on the mark 5 4 5 4 Half flush float Move float down, flush volume increases. Half Flush Float : should be set on the mark Full Flush djustor : should be set on the mark Half Flush djustor : should be set on the.5 mark : installation Full flush adjustor Move adjustor down, flush volume increases. Half flush adjustor Move adjustor down, flush volume increases. Body Flush Valve Seat Nut Doughnut Cistern : trouble shooting Problem Leakage No flush, low flush or half flush volume Half flush water level is too high or too low. Reason. Incorrect installation.. Flush valve seat does not fit flush valve body.. Flush valve body is stuck. Cable is distorted. Water level is adjusted incorrectly. Solution. Install again according to the correct installation procedure.. Install again.. Disconnet and wash flush valve body. Remove kinks or sharp bends in the cable. djust water level. 4-5
Nut Lever Pull B B Direction : Install Close Coupled Cistern To Pan * Please ensure the flush cone is in position before installation. Close Coupled Cistern & Flush Level Installation : Install Lever 5-5 Clamp the cistern and pan with the bolts as shown on the left. washer Plastic washer Fixing nut Water supply Install the cistern as shown and tighten the fixing nuts. Connect the water supply to the cistern. Flush Button Box Insert the box and tighten the nut. Fixing Nut Plastic * Raise the lever so that it fits into the flush box in the correct position. nti-rotation * The fixing nut should be tightened as much as possible to avoid the cistern lever working loose during operation. * Make sure the cable is not distorted or kinked. Cistern Lever Hole Slot In The Thread Note: fter installation check that the full flush and half flush are working correctly. Please consult the trouble shooting pages if there are any problems. * With the lever facing outward and the slot on the thread facing upwards, fix the lever to cistern.