3 litres. 6 litres. Lever Flush Cistern Fittings - Close Coupled / Low Level Cistern 51cm - Close Coupled / Low Level Cistern 44cm

Close Coupled/Low Level Cistern 51cm Ceramic lever C1 Close Coupled/Low Level Cistern 51cm Ceramic Front Button C2. 1: Inlet Valve 2: Flush Valve

C24 C30. Parts supplied: 1: Flush Valve installation

C25. Parts supplied: 1: Flush Valve installation

Insert the lower end of the flush pipe into the pan via the flush cone (supplied as part of the cistern fittings). HANDY HINT

Compact Concealed Toilet Cistern with Dual flush CNC1001

Maintenance Information

Installation Instructions : Huracan : Page 1

Logo/Company Name 4 w x.75 h. Assembly Instructions. 1) Remove base, back/back bar, pneumatic cylinder, casters/glides, and seat from box.

SERVICE MANUAL. Hollandia 300 Large

Holley High Performance Intake System* For Port 13B Engines (Includes B 6-Port engines converted to 4-Port)

REGULATORS ALPHA 8 SECOND STAGE OCEANIC ALPHA 8 SERVICE PROCEDURE

Installation Instructions

Installation Manual TWM Performance Short Shifter Cobalt SS/SC, SS/TC, HHR SS, Ion Redline and Saab 9-3

Installation Instructions

Installation Instructions JASMINE Spread Lavatory Faucet with the EverClean Finish & Speed Connect Drain

INSTALLATION MANUAL. Ford 3.5L F

Page 1 of 12 DZ /15/13

Installation Instructions : Huracan : Page 1

MODEL 872D MODEL 873N MODEL 872B POST-MIX BEVERAGE DISPENSER FOR USE WITH BAG-IN-BOX

Logo/Company Name 4 w x.75 h. Assembly Instructions. 1) Remove base, back/back bar, pneumatic cylinder, casters/glides, and seat from box.

12. CARBURETOR/FUEL PUMP

TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: FAX:

PH1 AIR INTAKE EMERGENCY SHUT-OFF VALVE PULL CABLE ACTUATION.

Installation must be in Accordance with AS/NZS

Installation Instructions Street Bandit Shifter

COMPONENT WORK SAMPLE 14 Integrated Peer Performance MAINTENANCE MANUAL

Installation Instructions Series Series

Installation Instructions

DUAL FLUSH VALVE SKIPPER 45 BOTTOM INLET VALVE COMPACT 99B ASSEMBLY INSTRUCTIONS

Installation Instructions

Trouble Shooting Guide for V100 Positioner

Lifecycle Upright Bikes LC95, LC91, LC85, C9, C7, 95Ce, 95Ci, 93Ci, and 90C How To... Replace the Intermediate Pulley Shaft and Bearings

Photo 1. Shift pattern gate plate

Clos-o-Mat Lima Lifter installation & user guide

CARBURETOR SERVICE INFORMATION TROUBLESHOOTING THROTTLE VALVE DISASSEMBLY THROTTLE VALVE INSTALLATION...

UOW Series Repair Manual UOW-11 & UOW-T60 Series

PNEUMATIC SLIDING VALVE

Height Adjustable Dual Flush Siphon

Operation and Maintenance Instructions

Maintenance Information

INSTALLATION MANUAL IMPORTANT CONSIDERATIONS TECHNICAL INFORMATION. Tools you may need

Winch Trouble Shooting Guide

INSTALLATION INSTRUCTIONS PATIENCE

Maintenance Information

DYNAFLUID 2000 STEAM & WATER MIXING VALVE INSTALLATION & OPERATING MANUAL

Installation Instructions

HexPro Series Low Profile Wrenches

Columbia Car Seat. User Guide. IMPORTANT Please retain this User Guide for future reference. Conforms to ECE R44.03 Universal

SEATING INSTRUCTIONS. Trooper

5.5 Wheel drive (wheel pilots only)

3M Overhaul Service Kit

200 HYDRO-TOWER 200. Ordering Information. Wall-hung Toilet That Matches The Tank. Function Explanation

Operation and Maintenance Instructions

Installation Manual TWM Performance Short Shift Kit Estimated Installation Time: Tools required:

DURA SHOT S SPRAYERS.

Low Profile Wrenches Operation and Maintenance Manual


Zip FlushMaster Surface mounted sensor

Installation Instructions

Maintenance Information

Owner s Manual MODEL NO: S400A SERIAL NUMBER 5000

Assembly and disassembly instructions for WP-Dynamic

Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.

Tri-roll External Thread Gage

OPERATIONS MANUAL LEVER CHAIN HOIST

Section 5. Trouble Shooting. Symptom Probable Cause Suggested Remedy

RUFNEX Series Low Profile Wrenches Operation and Maintenance Manual

INSTALLATION INSTRUCTIONS

powered by INSTALLATION MANUAL Ford 3.5L F Not legal for sale or use in California on pollution-controlled vehicles.

IBT Series Square Drive Torque Wrenches

TOUCH-ACTIVATED DUAL FLUSH WC FLUSHING SYSTEM - FRONT ACCESS

Installation Guide. Philips MP20/30/40/50 IntelliVue VHM Wall Mount Kit

OPERATION AND MAINTENANCE MANUAL

TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: FAX:

Maintenance Information

MP18 Stacking Valve System Technical Information Manual

HYDRAULIC TUBE CUTTER

Flow Control & Pressure Reducing Valve with Hydraulic Control (Sizes 3''- 12"; DN80-DN300)

COMPONENT WORK SAMPLE 8 Simulated Assembly MAINTENANCE MANUAL. From 1974 to March 15, 2003

SERIES OPERATION AND MAINTENANCE MANUAL

J2 Remove sound insulation/knee guard 1 and side panel 2 on center console

Instruction Manual Compac spring press, model CSC. Air operated

100 HYDRO-TOWER 100 ODEON

Technical Support (707)

TCI FastGate Shifter Installation Instructions

k. Components not properly adjusted. Refer to machine technical manual for proper adjustment of components.

MANUAL. Tyr MOT 250 English

11. CARBURETOR 11-0 CARBURETOR ZX / SCOUT 50

Basic Task (B) Chair Adjustment Information

MANUAL. TU Series. TU Series. Square Drive Hydraulic Torque Wrenches MODELS TU-2, TU-3, TU-5, TU-7, TU-11, TU-20, TU-27 & TU-60

C-Drive 7 Motor Control Unit For Electric Steering & Autopilots

A-PDF Split DEMO : Purchase from to remove the watermark

WATER SOFTENER SEMI AUTOMATIC INSTALLATION & OPERATING INSTRUCTIONS. Serial No :

Tillage System Model 46 Assembly Manual

WESCO INDUSTRIAL PRODUCTS, INC. Heavy Duty Semi Electric Pallet Truck. Part Number:

MANUAL. TU Series. TU Series. Square Drive Hydraulic Torque Wrenches MODELS TU-2, TU-3, TU-5, TU-7, TU-11, TU-20, TU-27 & TU-60

Installation Instructions

Installation Instructions : Ford Focus MK3 RS : Page 1 Tools Required: Philips screwdriver, trim removal tool, Torx, 10mm socket

FRONT WHEEL ALIGNMENT

Transcription:

Lever Flush Cistern Fittings rcade close coupled cistern RC5C ll WC s come with a /6 litre flush as standard which can be reduced to a.5/4.5 litre flush for the slimline cisterns On the Close Coupled WC you must press the lever down lightly for the 6 litre flush and lightly lift the lever for the litre flush litres 6 litres Please note that it is imperative that there are no loops or kinks in the yellow tube when installed and that the lever is not operated with excessive force as this will damage the cable inside the tube that lifts and lowers the flush valve causing the flush to fail beyond repair - 5

Lever Flush Cistern Fittings rcade close coupled cistern RC5C Parts supplied: Please read these instructions carefully to avoid damage Bolt Doughnut Fixing Nut to the valves, and to ensure correct installation. Do not use bleach or bleach based cleaning products in x the cistern, as these will cause damage to the seals. We cannot be held responsible or liable for any failure which results from the use of bleach based products. Water temperature range +C to +45C. Inlet Valve Lever Plastic Cone Flush Cone Water pressure 0. to 8 bar. : Inlet Valve scale and adjustment settings : Major water level adjustment 6L/L 4.5L/.6L 0 0 Exposed "" steps "0" scale Exposed "" steps "" scale Note: The inlet valve is preset for 6L full flush and L half flush. The above diagram indicates the correct setting for 6L/4.5L full flush and L/.6L half flush. For adjustment method, please refer to the right diagram. Take off locker Loosen the inlet body by turning slightly anti-clockwise, djust it up or down to correct position and tighten clockwise. Re-insert the locker - 5

B: Minor water level adjustment NOTE: djustment Rod Stop Float Stop Float djustment Rod Stop Float Float cup Stop Float Slide the locker to "unlock" position, Move the stop float up/down. To decrease the water level use a screw driver to adjust the level of the Stop Float (as shown).the float should be lowered. To increase the water level use a screw driver to adjust the level of the Stop Float (as shown).the float should be raised. Ensure the top surface of Stop Float is in line with the top surface of the Float Cup. Slide the locker to the "locked" position : Inlet Valve installation : Filter cleaning (Please clean periodically) Cistern Inlet Valve Inlet valve Plastic Nut 4: Inlet Valve trouble shooting Problem Incorrect water level Inlet Valve does not work Tighten the nut after having adjusted the lnlet valve calibration as per page &. Reason Incorrect adjustment. Water supply is closed. The filter is blocked. Filter Pull out the filter from the Inlet valve. Clean the filter. Solution djust the Water. level correctly as per page &. Open the water supply Filter Clean by rinsing the filter. Insert the filter back into the Inlet valve. Leakage The Stop Float has been over adjusted beyond its operational range. The Inlet Valve fixing nut has not been tightened. Reconnect the djustment Rod, and adjust the water level as per on page. Tighten the nut. - 5

: scale and adjustment setting Installation nd Problem Solving Note: The is preset for 6L full flush and L half flush. The diagram below indicates the correct setting for 6L full flush and L half flush. The diagram B below indicates the correct setting for 4.5L full flush and.6l half flush. B Half Flush Float : should be set on the.5 mark Full Flush djustor : should be set on the.5 mark Half Flush djustor : should be set on the mark 5 4 5 4 Half flush float Move float down, flush volume increases. Half Flush Float : should be set on the mark Full Flush djustor : should be set on the mark Half Flush djustor : should be set on the.5 mark : installation Full flush adjustor Move adjustor down, flush volume increases. Half flush adjustor Move adjustor down, flush volume increases. Body Flush Valve Seat Nut Doughnut Cistern : trouble shooting Problem Leakage No flush, low flush or half flush volume Half flush water level is too high or too low. Reason. Incorrect installation.. Flush valve seat does not fit flush valve body.. Flush valve body is stuck. Cable is distorted. Water level is adjusted incorrectly. Solution. Install again according to the correct installation procedure.. Install again.. Disconnet and wash flush valve body. Remove kinks or sharp bends in the cable. djust water level. 4-5

Nut Lever Pull B B Direction : Install Close Coupled Cistern To Pan * Please ensure the flush cone is in position before installation. Close Coupled Cistern & Flush Level Installation : Install Lever 5-5 Clamp the cistern and pan with the bolts as shown on the left. washer Plastic washer Fixing nut Water supply Install the cistern as shown and tighten the fixing nuts. Connect the water supply to the cistern. Flush Button Box Insert the box and tighten the nut. Fixing Nut Plastic * Raise the lever so that it fits into the flush box in the correct position. nti-rotation * The fixing nut should be tightened as much as possible to avoid the cistern lever working loose during operation. * Make sure the cable is not distorted or kinked. Cistern Lever Hole Slot In The Thread Note: fter installation check that the full flush and half flush are working correctly. Please consult the trouble shooting pages if there are any problems. * With the lever facing outward and the slot on the thread facing upwards, fix the lever to cistern.