Operating Instructions. Tronic Dimmer

Similar documents
Operating Instructions Electronic transformers for lowvoltage halogen lamps

Figure 1: Device components

1 Safety instructions. 2 Device components. Light Management Rotary dimmer. Operating instructions

1 Safety instructions. 2 Device components. Light Management LED touch dimmer insert. Art. No LEDDE. Operating instructions

Operating Instructions 2-channel pushbutton interface 4-channel pushbutton interface

1 Safety instructions. 2 Device components. Dimmer push-button/2-way low voltage. Order No. : Operating instructions

1 Safety instructions

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. LB management. Universal touch dimmer insert LED

System 2000 DRA automatic stairway lighting, Impulse insert. 1 Safety instructions. 2 Device components

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. System Universal LED dimming insert Standard

UNIVERSAL PUSHBUTTON DIMMER ETD 2 (Rail mount version)

Power enhancement for the dimmers contained in the reference list (see section Technical

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

INSTALLATION & MAINTENANCE MANUAL HBL

1 Safety instructions. 2 Device components. Blinds Management Motor control insert Universal AC 230 V ~ Art. No. 232 ME. Operating instructions

Total solder points: 126 Difficulty level: beginner advanced POWER DIMMER 230V) K8038 ILLUSTRATED ASSEMBLY MANUAL

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

2-Way Dimmer (1 Gang)

ADVANCED GUIDE TO LED LIGHTS & DRIVERS. astrolighting.com

ADVANCED GUIDE TO LED LIGHTS & DRIVERS. astrolighting.com

2-Way Dimmer (1 Gang)

Energy Profile Installation Instructions

Dimmer / 2-Way Dimmer

The right light for every room with Eltako dimmer switches

ABB i-bus KNX Room Master, MDRC RM/S 4.1, 2CDG R0011

The right light for every room with Eltako dimmer switches.

ABB i-bus KNX DG/S x DALI-Gateway Basic

GP12 TECHNICAL MANUAL

Dimmer Switch (1 Gang)

Installation & User Instructions

Wireless Dimmer Installation and User Guide

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCD ECO, W Compact and T5c fluorescent lamps

The Standard for Incandescent Replacement ISSUE 3

LEDVANCE SUPERSTAR LED Downlight Gen 2

LED AR111 Instruction Manual

ACCESSORIES ACCESSORIES CCESSORIES A 312. DIMMERS 315. SENSORS 318. CONNECTORS 320. SADDLES 321. SURFACE SOCKETS 322. BATTEN FIXTURE 322.

1 Safety instructions. 2 Device components. System Blind control insert with auxiliary input

Command and signalling E 250, E 259 selection table

Skylark C L Dimmer. Skylark. Wallbox Controls. Dimmer for CFL and LED dimmable bulbs.

PRODUCT SPECIFICATION OUTPUT CURRENT (A) OUTPUT CURRENT TOLERANCE ±7% ±7% ±10% ±10% ±7% 1.8. Units % % % Typ. Typ.

Push Button Units and Indicator Lights

SECTION MOTORS & MOTOR CONTROLLERS

LED CONVERTERS FOR LED MODULES 24 V

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

Lumea C L Dimmer. Wallbox Controls

Motor Starter Reverse MSR22-FBP

Replace ** for the required coil voltage eg: P7 (230V 50/60Hz) Co nt act or Heating Guides, 9-95A

OUTDOOR TRACK. LABELS Assembled in America

HomeWorks QS Designer RF Maestro Local Controls

CI-TI Contactors and motor starters Types CI 61 - CI 98

QTi DALI 1X36/ DIM

HomeWorks QS RF C L Hybrid seetouch Keypads

Transformers for Low-voltage Halogen Incandescent Lamps

Installation Instructions

Technical information

RadioRA 2 Maestro Local Controls

RadioRA 2 Maestro Local Controls

Taxonomies, Classifications, and Categories Residential dimmers, motion sensors, controls, & photo cells

BSW , -493, -494 Mechanical Rotary Cam Switches. User's Guide. Mechanical Rotary Cam Switches BSW BSW BSW

Skylark C L Dimmer. Skylark. C L Dimmer. Wallbox Controls

Garden. powered by. G551 - Corso. powered by LUMASCAPE

Installation Instructions

UV- TECHNOLOGY. Technical Documentation ELC N6 / ELC N8 / ELC N10

TWIGGY T1, TUBULAR 1" LENS TUNABLE WHITE 24VDC SYSTEM, 90+CRI

Einschaltverzögerung. Schaltwert 1 Schaltwert 2 Schaltwert 3. Schaltwerte in Lux. Wiedereinschaltsperre x 20 x 1 Ein Aus

Skylark C L Dimmer. Skylark. C L Dimmer. Wallbox Controls

1.7. Portable insulation fault location system EDS3060/EDS3360 in combination with EDS460/461 systems

Ford Scorpio 95+ Charging System

MODULAR DEVICES. 21. Isolator Switches. Low Voltage (Bell) Transformers. Time Switches (electromechanical)

M-SERIES MAGNITUDE LIGHTING MAGNETIC DIMMABLE CLASS 2 LED DRIVER QUICK SPECS ENCLOSURE DETAILS

Maestro Wireless Dimmers and Switches

Garden. Powered by LUMASCAPE. G551 - Corso. powered by LUMASCAPE

Fluorescent (non-capacitive) Metal Halide 10A. 2 Any load circuit can be connected to any phase.

UL/cUL FILE NUMBER E CE See last page of manual for CE Declaration of Conformity.

Technical Manual Electrical Power Supply System T4002

New dimming drivers are compatible with most wall dimmers for % light control. For non-dimming

Universal push-button dimmer with PLC interference suppression, W, 2-wire

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Skylark Contour C L Dimmer

CR Series and DR Series LED Downlights EASY TO INSTALL WITH UNPRECEDENTED PAYBACK

SINAMICS GM150 IGCT version

Event Spot WW Triac. User Manual. Order codes: LEDJ237 - Black Housing LEDJ237A - White Housing

Ariadni 250 W C L Dimmer

DELTA i-system. 1/6 Introduction. 1/7 Switches and pushbuttons. 1/13 Shutter/blind controls. 1/19 Socket outlets

Vive Maestro Wireless Dimmers and Switches

Technical Data. Dimmer Switches - Push Type 881P/885P 882P 883P 884P

Frequently Asked Questions

Motion and Light Sensor Kit LHBAS51

Safety Sensor CSS 180 Product Information

Local Control Network - building controls in perfection

Step 1: Parts List and Bike Preparation

Maestro Wireless Dimmers and Switches

DIN Power Module - Phase Adaptive

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

PD3PCLWH Table/Floor Lamp Dimmer

Contactor Types CI 61-98

Isolating transformer DS0107. Three-phase isolating transformers for the supply of three-phase loads in medical locations

DIMMERS. Slide Dimmers C3. Rotary Dimmers. Touch Dimmers C5. Decorator Dimmers C6 C-1

Installation Instructions

IVIOS LED III. LUM Technical Information

Transcription:

Operating Instructions 1. Warning Caution! The installation and assembly of electrical equipment may only be performed by a skilled electrician. Not suitable for disconnecting. The load is not galvanically separated from the mains when the TRONIC dimmer is off. Non-observance of the installation instructions may result in fire or other hazards. 2. Function With the aid of this Tronic dimmer, halogen low-voltage lamps with Tronic transformers, 230 V incandescent lamps, or halogen high-voltage lamps, or mixed loads of specified types are dimmable. Switching and dimming commands can be given by operating an extension (mechanical push button, normally-open contact) Lamp-saving soft start guarantees optimum lamp life. Short push button operation: ON OFF Longer push button operation: Dimming Two possibilities for switching on or dimming are available (refer to Fig. ) : Memory switch = OFF: Always switching on maximum brightness. Dimming function begins at minimum brightness. Memory switch = ON: Always switching on the brightness set last. Dimming function begins at the brightness set last. Stand: Jan-09 325 424 13

This Tronic dimmer is a part of the TRONIC light control system. Mains failures of > 200 ms may possibly lead to switching off the dimmer and to the loss of the brightness value stored. Fig. 3. Short-Circuit Protection Disconnection with automatic re-starting after elimination of the shortcircuit within 7 seconds. After this, permanent disconnection until the TRONIC dimmer is re-started manually. 4. Overtemperature Protection Disconnection in case of excessively high ambient temperature. After cooling down, the unit must be restarted. 5. Installation Instructions These units are designed as series built-in equipment to be snapped onto the mounting rail. The maximum installed load is 500 W for 230 V incandescent lamps, halogen high-voltage lamps or a maximum of 14 35-W TRONIC transformers, or a maximum of 8 60-W TRONIC transformers, or a maximum of 7 70-W TRONIC transformers, or a maximum of 4 105-W TRONIC transformers, or a maximum of 3 150-W TRONIC transformers, or a maximum of 2 200-W TRONIC transformers. To ensure optimum spike protection of the dimmer/ transformer combination, observe the above maximum number of transformers to be connected in parallel. The total power of the lamp load installed must not exceed 500 W. 2

Connect as shown in Fig. 2. Fig. 2 The connection of inductive loads (iron-core transformers) is inadmissible. Centralised multi-service control pulses of the electricity works may be noticeable by short-time flickering at low dimming positions. When the TRONIC dimmer is fully utilised, up to 10 TRONIC power attachment or built-in TRONIC power attachments (refer to Fig. 3) can be connected in order to extend the installed load. 3

Fig. 3 4

6. Technical data Rated voltage: Installed load: 230 V AC, 50 Hz 50-500 W TRONIC transformers 230 V incandescent lamps Halogen high-voltage lamps Mixed loads of the types specified Ambient temperature (Ta): 45 C Enclosure temperature (Tc): 75 C Dimensions: 4 PU Max. number of power attachments to be connected: 10 Extension: mechanical push button (normally-open contact) Number of extensions: Unlimited Illuminated mechanical pushbuttons must have a separate N terminal. Connection terminals: 1, L, 7. Guarantee Our products are under guarantee within the scope of the statutory provisions. Please return the unit postage paid to our central service department giving a brief description of the fault: ALBRECHT JUNG GMBH & CO. KG Service-Center Kupferstr. 17-19 D-44532 Lünen Service-Line: +(49) 23 55. 80 65 51 Telefax: +(49) 23 55. 80 61 65 E-Mail: mail.vka@jung.de General equipment Service-Line: +(49) 23 55. 80 65 55 Telefax: +(49) 23 55. 80 62 55 E-Mail: mail.vkm@jung.de KNX equipment Service-Line: +(49) 23 55. 80 65 56 Telefax: +(49) 23 55. 80 62 55 E-Mail: mail.vkm@jung.de The CE-Sign is a free trade sign addressed exclusively to the authorities and does not include any warranty of any properties. 5