OSRAM GmbH Hellabrunner Str. 1 D Munich Tel.: +49 (0) Fax: +49 (0)

Similar documents
SWING GATE OPENERS 24V DC GEAR MOTOR

Eazidraw Cordless. Installation & Set Up Instructions. Electric Blinds & Curtains

PW320/PW330 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL. Flashing Light. Push Button. Control box. Gate 2.

PW150/PW200 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR

Eazipole Cordless. Installation & Set Up Instructions. Electric Blinds & Curtains

Wireless doorbell transmitter FS20 TK

PrevaLED Cube G2. Product family datasheet. Spot-, Down- and Wallmount Light Engines and Modules

Tyre Pressure Monitoring System

X Cube Lift. Model: XCU 190 XCU 180 Installation Instructions

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

Heat Meter Integrator

Sectional And Tilting Door Opener

ABB i-bus KNX Magnetic Contact EnOcean, 868 MHz MKE/A , 2CDG R0011

Bosch Smart Home. Door/Window Contact Instruction Manual

Remote Programming Guide

ENG AFTER-MARKET DEVICE FOR THE IMPLEMENTATION OF AN AUTOMATIC SWITCH CONTROL OF HEADLAMP LIGHT Installation & User Handbook

OPERATING INSTRUCTIONS

Energy Profile Installation Instructions

DESIGNED FOR RESIDENTIAL APPLICATION KIT PL600/PL1000 SLIDING GATE OPENERS

Operating Instructions (Translation)

Remote Engine Start System User s Information Manual

Operating instructions. FreeCon Contactless Power Contactless power transmission IE-CL240W-PP-BASE IE-CL240W-PP-REMOTE

MOTOR MANUAL. Rev 9.2 TRSX-36024V. Note: Check our website for the latest version of this manual. Super Target Systems.

Operating Instructions. bluesmart Active

Inazuma Installation and Operating Instructions INAZUMA HD PRO UV-C. High-Performence Duo UVC Lamp

Instruction manual. Liftkar HD Uni Liftkar HD Fold Liftkar HD Dolly Liftkar HD Fold Dolly. Issued: 10/2010 subject to updates.

Module B Module C FOR THE WEATHER CONTROLLER MULTI-MIX INSTALLATION MANUAL REVISION: 1.0_EN

p wered BLINDS control at your fingertips Installation, Programming & Operation Guide 12Vdc Powered Roman Blind

Sectional and Tilting Door Opener Installation Instructions and User Guide

Smile 11 RA/-B Smile 12 RF/-G Reset button

Endura AZ10 Oxygen probe Sensor sub-assembly tested spares kit

Target Retrieval Systems

SensoStar C. Installation and Operating Instructions Heat Meter Calculator Heat/Cooling Meter Calculator Cooling Meter Calculator

Type MZ15. Operating Instructions. Bedienungsanleitung Manuel d utilisation

Remote Engine Starter System I User s Information Manual

REVO-1 & REVO-4 SERIES 1 - Way Remote Start System

TABLE OF CONTENTS. 8.3 Online Sensor Specifications. Series TS (Models TS1, TSP, TSH, TSL,TSF, TSB1, TSB2) According to Electromatic factory procedure

Accessories for Stand-alone inverter SUNNY ISLAND GENMAN

Wireless Remote System RC-12v & 24v Standard RF Remote Control System INSTALLATION MANUAL AND OWNERS GUIDE Table of Contents:

LINEARLIGHT POWER FLEX LF06P2 TECHNICAL DATASHEET

ABB i-bus KNX DG/S x DALI-Gateway Basic

INTECH Micro 2300-RTD6

IVTM Installation Manual

ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2

Instruction Manual LA-SDO1 Sectional garage door opener

Scissor Lift Model : SC60 SC40 Installation Instructions

TABLE OF CONTENTS 10.0 WARRANTY

CM3-E Operation Manual DOK-347E / Rev.:1.01 KH / October 1999 Portable 3 turbine check meter

nual k Voltage Stabilizer N) manual New Brunswick Voltage Stabilizer Operating manual

Level Measuring Sensor for Diesel Fuel Tanks

WATERFLUX 3070 Quick Start

EGQ 212: Duct transducer, CO 2 and temperature

Datasheet PDCSY-MW-U. Technical Overview. Features. Product warranty and total quality commitment.

Remote Control Engine Starter System Owner s Manual

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

7 Lighting Technology

NOKOMMS. kéï=~ë=çñw= pfoliru c^kq^pqf` fåëí~ää~íáçå=fåëíêìåíáçåë=iáöüí=qê~åâ=póëíéã. båöäáëü

GEIGER GJ56.. AIR (GJ56.. F03) for Venetian blinds

Roller Shade Installation Instructions

Oil-free piston compressors KK and piston vacuum pumps KV

OMATION FOR SLIDING GATES LINESTAR INSTALLATION MANUAL

Dry Contact Closure Interface

Installation manual ASTER AUTOMATION FOR SWING GATES 11_16

OPERATING AND USERS MANUAL

PORTAGAUGE 4 USER MANUAL

Tina 10A/B/C Adaptor unit

INSTALLATION INSTRUCTIONS SLIDING SHUTTER MOTOR

The Brose e-bike system. Instructions for use

Register your instrument! HeatSealer S100. Operating manual

Installation & Maintenance Instructions MULTICAL 403. Supplied by. .com. Call us on +44 (0)

Ropox Shower & Changing Bed

APOLLO Gate Operators, Inc.

SECTIONAL AND TILTING DOOR OPENER INSTALLATION INSTRUCTIONS AND USER GUIDE. Comfort 800E/1000E

Installation Guide Rollerdor RD55 Econ Roller Garage Door

TruSystem 7000 One table without limits

Operating Instructions 2-channel pushbutton interface 4-channel pushbutton interface

Wireless Temperature/Humidity Station

FL ballasts Electronic fixed output. PC TCL PRO, W PC PRO compact

PSS 5000 Standard & Compact (For systems with CPB50x)

VERG 24V BARRIER. English

Ignition Switch. Ignition Switch. To Remove the Ignition Key. Gearshift Interlock. Steering Column Lock

integra trim ltd. Holiday Home: EASTER/SPRING Try Me Hang Tag - Children s Product I Play or I Sing Goes Here Name of Song TRY ME! Product Name 2 in.

Sectional and Tilting Door Opener

Operator s manual Manuel d utilisation Manual de instrucciones. BLi520x BLi940x

GARAGE DOOR OPERATOR USER S MANUAL

INSTALLATION MANUAL (cod )

MODELS MC100, MC100C, MC100-P2 AND MC100C-P2 Universal Mini Remote Control

FMC-1/2 Tina Muting unit

Operating Instructions. VEGASWING 61, 63 with oscillator SW E60N (EX)

Tina 11A Connection block

Electromotoric Actuators

MOTORIZED ROLLER SHADES PROGRAMMING GUIDE OTTO 30 OTTO DC2

Remote Engine Starter System User s Information Manual BAM02767

cover plate Instructions for Use suitable for Viega Eco Plus universal shower WC element, model from 08/2015 en_int

RHD500, RHD800 (Contrac) Electrical Part-Turn Actuators. For continuous positioning, rated torque 500 / 800 Nm (400 / 600 lbf-ft)

AXIAL FANS Axis / Tubo OPERATION MANUAL

Roller Shades MOTORIZED SHADE. Simplicity. Installation & Care Instructions

NCR ma/hart four-wire

Digital Scale. Revision 1.0 August 17, Contents subject to change without notice.

CATALOGUE Opto-Electronics STRACK LIFT AUTOMATION ILGT

Transcription:

Installation and operating instructions: Wall control unit Type: DALI WCU 2/4/8 ADVANCED W/M White version: DALI WCU 8 ADVANCED W Metallic version: DALI WCU 8 ADVANCED M OSRAM GmbH Hellabrunner Str. 1 D-81536 Munich Tel.: +49 (0) 89 6213 0 Fax: +49 (0) 89 6213 2020 Customer Service Center (KSC) Germany Albert-Schweitzer-Str. 64 D-81735 Munich Tel.: +49 (0) 1803 677 200 Fax:+49 (0) 1803 677 202 www.osram.com

Contents 1. Function overview... Page 3 2. Operation... Page 4 3. Programming in the DALI ADVANCED central unit... Page 4 4. Installation/changing batteries... Page 6 5. Notes on radio operation... Page 7 6. Technical data... Page 8 Page 2 Installation and operating instructions: Wall Control Unit DALI WCU 2/4/8 ADVANCED W/M

1. Function overview Wall control units DALI WCU 2/4/8 ADVANCED W/M can be used to operate a DALI ADVANCED system. Various functions can be assigned to the wall control units. The wall control units are available as 1-channel (2 switches), 2-channel (4 switches) and 4-channel (8 switches) versions and with either a white or metallic finish. Each pair of facing switches belongs to one channel. Button positions: white metallic 1-channel version: Fig. A 2-channel version: 4-channel version: A signal is sent when a button is pressed. An LED lights up by way of confirmation. Each transmitter is equipped with a three-way function switch (DIP switch) at the back for setting the required functions on the wall control unit. The following functions are possible depending on the setting: Abb. B Function switch Function of In OFF setting In ON setting F2 Button 1- Button 1+ All off Light scene 1 Channel 1- Channel 1+ F3 Button 2- Button 2+ Light scene 2 Light scene 3 Channel 2- Channel 2+ F4 Button 3- Button 3+ Light scene 4 Light scene 5 Channel 3- Channel 3+ Note: Buttons 4+ and 4- always correspond to channel 4+ and 4- The "All off" button cannot be assigned to a scene. Installation and operating instructions: Wall Control Unit DALI WCU 2/4/8 ADVANCED W/M Page 3

2. Operation Channel buttons: Pressing on "+" or "-" for no more than 1 second will switch the lighting system on or off. Holding down "+" or "-" for more than one second will fade the lighting system up or down. Lighting scene: Holding down a scene button (for at least 3 seconds) will store a lighting scene; briefly pressing a scene button will call up the lighting scene. Changing a lighting scene: 1. Set up the lighting arrangement you want with the group buttons. 2. Hold down a lighting scene button until all the lamps "flash" once (this confirms that the scene has been stored). 3. The lighting arrangement you have set up is now stored under the button as a lighting scene. 3. Programming in the DALI ADVANCED central unit The wall control unit must be programmed in the central unit so that the central unit can identify it as part of the system ( see also the operating instructions for the manual programming unit). Important: Each pair of buttons (+ and -) on the wall control unit must be programmed separately as each function can be assigned individually. The "All off" button must be held down for longer than 2 seconds. Before programming in the central unit, the selector switches at the back must be set according to their functions. See Fig. B. Please carry out the following: 1. Unscrew the wall control unit from the base plate as shown in Fig. C. 2. Select the functions for the buttons with the function switch (Fig. D1) on the back of the wall control unit (according to the table in Fig. B). The function can be changed at any time by changing the individual switches on function switch F(2...4). The new function must be programmed in the central unit. 3. Screw the wall control unit back on the base plate. Fig. C: Fig. D: 3 4 2 ON OFF Batt.: 2x CR 2016 ON OFF 4 K3 +/- LS4/LS5 3 K2 +/- LS2/LS3 2 K1 +/- LS1/Alles Aus Page 4 Installation and operating instructions: Wall Control Unit DALI WCU 2/4/8 ADVANCED W/M

Important: If the function of a wall control unit is changed it is best to delete the old function from the central unit. Programming in the central unit: ( see also the operating instructions for the manual programming unit) 1. Start the "Radio start up" programming mode on the manual programming unit (MPU). 2. Channel programming: Programming a channel button: Press the button for the required channel until the MPU confirms that it has received the signal. In the MPU, define the function that the channel is to perform (e.g. control of group 1). Programming a lighting scene button: Press the required lighting scene button until the MPU confirms that it has received the signal. In the MPU, define the scene that this button is to control (e.g. for lighting scene button 1: control of scene 1). Programming the "All off" button: Press the "All off" button until the MPU confirms that it has received the signal. In the MPU, define the function that this button is to control. The "All off" button, like the channel buttons, can apply either to all the connected receivers (central control) or to just one particular group (e.g. control of group 1). 3. Terminate radio start up on the MPU. This completes the programming process. The programmed functions can be entered in the label field. Deleting channels: Channels that have been programmed can be deleted in the "Untrained Channel" menu option on the manual programming unit (for details see the operating instructions for the manual programming unit). Notes: The maximum duration of transmission is 12 seconds (even if the button is held down longer). We also recommend that you label the wall control unit with the device number indicated on the MPU and enter this number in the documentation for the lighting system. Installation and operating instructions: Wall Control Unit DALI WCU 2/4/8 ADVANCED W/M Page 5

4. Installation/changing batteries: Important: The wall control unit must not be installed on metal. The distance between the unit and metal parts, such as door frames, must not be less than 10 cm. Electrical equipment may only be installed by qualified electricians. Batteries: The wall control unit operates on two CR 2016 lithium button cells (included). If you press a button for less than 3 seconds and the LED flashes five times, please replace the batteries. Notes on risks and disposal: Important: Keep batteries away from children. If a battery is swallowed, seek medical attention immediately. Old batteries should be removed immediately and disposed of properly. Replace batteries with ones of the same type. Installing the wall control unit: 1. Remove the label cover carefully with a screwdriver (Fig. C). 2. Loosen the screws underneath the cover and take the wall control unit off the base plate. 3. Attach the base plate of the wall control unit to a level surface (e.g. plaster, wood, glass, mirror or switch box) with adhesive pads or screws. Make sure the letters "TOP" are at the top. 4. Position the unit on the base plate 5. Tighten the screws again. 6. Replace the label cover. Changing the batteries: xx Steps 1 and 2 as above 3.1 Remove the old batteries carefully with a screwdriver through the notch in the casing (Fig. E). Take care not to damage the battery holder. 3.2 Make sure the new batteries are the right way round as shown in Fig. F ( on top). 3.3 Press any button for about 1 second to test the batteries (the LED will light) xx Steps 4 to 6 as above Fig. E: Fig. F: 3 4 2 ON OFF Batt.: 2x CR 2016 ON OFF 4 K3 +/- LS4/LS5 3 K2 +/- LS2/LS3 2 K1 +/- LS1/Alles Aus Page 6 Installation and operating instructions: Wall Control Unit DALI WCU 2/4/8 ADVANCED W/M

4. Notes on radio operation A non-exclusive transmission path is used for radio transmission, which means that interference cannot be ruled out. Radio transmission is not suitable for safety applications, such as emergency shutdown or calls to the emergency services. The range of the unit (up to 30 m in the open) depends on the nature of the building: Dry material Penetration Wood, plaster, plasterboard approx. 90 % Brick, MDF approx. 70 % Reinforced concrete approx. 30 % Metal, metal grating, aluminium approx. 10 % cladding This radio system may only be connected to other communication networks if this does not infringe the relevant national laws. This radio system may not be used for communicating beyond property boundaries. If operated in Germany, the regulations contained in Official Bulletin Vfg 73/2000 must be met. The wall control unit may be operated in all EU and EFTA states. Installation and operating instructions: Wall Control Unit DALI WCU 2/4/8 ADVANCED W/M Page 7

5. Technical data Power supply: Batteries: Battery life: Transmission frequency: Range: 6 V DC 2 x lithium button cells (CR2016) approx. 3 years 433.42 MHz, ASK typ. 30 m (in the open) Temperature range: 0 C to +55 C Relative humidity: max. 80 % (no condensation) Type of protection: IP 20 Digital Addressable Lighting Interface The international digital interface standard for the lighting industry Date 13.09.02 / Wall Control Unit ADVANCED Version 1.0 Subject to change without notice. Errors and omission excepted. Page 8 Installation and operating instructions: Wall Control Unit DALI WCU 2/4/8 ADVANCED W/M