Prídavné moduly pre RS232 a RS485

Similar documents
DESIGO V6. Siemens AG All rights reserved. BT HQ

Automated Precision Weighing

Communication module. Brief description. Block structure Features. Page 1/5. Data Sheet

Automated Precision Weighing

ThinkTop DeviceNetTM VDC DeviceNet is a Trademark of the Open DeviceNet Vendor Association, Inc. (ODVA).

AFP TM EAC Electrical Rotary Actuator

LOAD CELL-JUNCTION BOX- INDICATOR CONNECTION

FATEK FB/FBs/B1/B1z Series

Remote Process Actuation Control System AirLINE WAGO Remote I/Os and Fieldbusses

AIR THROTTLE CONTROL MODEL# ATI-ANALOG PART#

Features and Benefits. Certifications

Technické údaje Golf Variant 2017 Golf Variant

kyleave Surveillance to the Top

PKS-FD Servo System

SED2. Variable Frequency Drives. with Conventional Bypass Options. Variable Frequency Drives. Description. Features F-9.

Solenoidné ventily. Solenoid pilot valve

KNC-PKS-FD S-AAK-DKH

Kössler... mení vodu na energiu. A Voith and Siemens Company PPT-Anleitung Uwe Gobbers

GS2 Series - Introduction

HMM Series Mechanical Heat Meters

Datasheet PDCSY-MW-U. Technical Overview. Features. Product warranty and total quality commitment.

ES Housing ES Battery Pack. User s Guide

Model 212A Smart SerialPRO Interface User s Guide

PLC Stamp micro 2 Datasheet

WEGA-MODULE2 LED Recessed Mounting

PLC Stamp mini 2 Datasheet

Technické údaje Passat

Technické údaje Passat Variant

Temposonics. Magnetostrictive Linear-Position Sensors. R-Series Model RP and RH Sensors Synchronous Serial Interface (SSI) Output D

ABB AC500 Technical Help Sheet

Heat Meter Integrator

Series RE-46. Valve terminals > Technical details. Order code RE-46/**-*-***-*** Temperature range Medium -10 C C

LABOR ASTER INDUSTRIAL AUTOMATION. Intrinsically safe barrier with separation FIELDBUS TRANSMISSION LINES CONVERTER-SEPARATOR

: LightBox Displays : Informačné a reklamné svietidlá

SSI. Synchronous Serial Interface

PRM7-04. Functional Description HA /2012. Proportional Directional Control Valves. Replaces HA /2009

Series RE-10. Valve terminals > Technical details. Order code RE-10/**-***-*** Temperature range Medium +5 C C

APS & APIS ATEX AIRPOWER SWITCH BOXES FEATURES DESCRIPTION

Electrical Actuators

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

TURCK Network Media Products PROFIBUS -DP

PRM7-06. Functional Description HA /2006. Proportional Directional Control Valves. Replaces HA /2002

PRM7-06. Functional Description HA /2014. Proportional Directional Control Valves. Replaces HA /2013

Content 1. Laserline series 3

Hydraulic Valves «DSV»

CARRARO TRAX TLB2 Electronic Module Specification. 29/11/2006, Rev. 5

Logic module. Brief description. Features. Block structure. Data Sheet Page 1/5

ZT-USB Series User Manual

Installation and User Guide CCMS312

M2-iLAN-2 Laser Scanner

CTPundercarriage Track Rollers Link Assemblies Sprockets Idlers Spring Assemblies Track Shoes Track Guides Track Pins Bushings & More

For GVXXX-Series Devices

User Manual Rittal PMC UPS 6kVA

RS485 MODBUS Card. User Manual. Before you start to install this card, please read this User Manual carefully

TECHNICKÉ ODPORÚČANIA RENAULT TRUCKS PRE AUTORIZOVANÝCH PREDAJCOV A SERVISY (2012)

HDCD8TP 8-Way RS485/RS232 to RS485 Bi-directional Distribution Box

Operating Instructions Control 330 Conductivity meter

Tethered Trailer Tracks (TT100) Quick Installation Guide

AFP MEA Mini Electrical Rotary Actuator User s Instructions

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

VAHLE POWERCOM 485. Digital Data Transmission System

premier product range

USER MANUAL W ONBOARD GENERATOR SYSTEM

User s Manual. RS232. TPMS 6-13 connection

Instruction Manual Installation and Operation Guidelines for DWL5000XY and DWL5500XY Tilt Sensor Modules (Version 2.2)

Uninterruptible Power System

Euro 5 manažment motora. Zlepšenia kvality. Redukcia Emisii

RS485 board. EB062

Proportional relief valves with integral pressure transducer

TECHNICAL DATASHEET Stainless Steel Encoder AC 61 - Profinet

VAHLE POWERCOM 485. Digital Data Transmission System

User s manual. RS232. PressurePro tire-pressure monitoring system connection

MC-CRX. Bill Acceptor Card Reader Combo. Operation & Service Manual

Proportional pressure reducing valves type DHRZO direct operated, ISO 4401 size 06

True Fail-Safe Technology and Precision Control for Reliable Shutdown

Operating Instructions

Harris IRT Enterprises Digital Resistance Tester Model XP

Low voltage AC drives

CANBUS G. Up to mm ( in.) < ± 0.01% of full stroke or ± 0.04 mm ( in.), whichever is greater*

SWII Users Manual. Intercomp Co County Road 116 Minneapolis, MN (763) Fax

Stainless steel Material : DIN / /

1/4" PIF 1 5/16" PIF 5 3/8" PIF 2 6 mm PIF 6 8 mm PIF 8 10 mm PIF Y No PIF (for Pneumapole) 7*

Dispense interface converter NA-8 (RS-485/RS-232 to non-addressable RS-422/RS-485/RS-232 and backwards)

BT300 Variable Frequency Drives Redesigned, re-tooled, and ready to meet rigorous demands Answers for Infrastructure.

MCS-BMS-GATEWAY STARTUP GUIDE Covers Model No. FPC-C35

ProtoNode FPC-N34 and FPC-N35

GSM GSM TECHNICAL May 1996 SPECIFICATION Version 5.1.0

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

zlepšení úžitkových vlastností - zníženie deformácií - redukcia pnutia vo výstuži - zmenšenie prasklín - redukcia únavy materiálu;

Installation Instructions for: Channel Thermocouple Amplifier

Proportional relief valves

Temposonics. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. R-Series Models RP and RH Ethernet POWERLINK.

Hi-Z USB Wireless. Introduction/Welcome

Proportional reducing valves

Operating manual. LabStation LS Flex/430

EIP APPLICABILITY & EFFECTIVITY

Delta Products VFD CP2000 Bypass Control Packages.

Wide Bank 28 DS3 QUICK START GUIDE

CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description

BDMS / BTMS. Bearing Distance and Temperature Monitoring System. For two stroke diesel engines

Transcription:

9 281 DEIGO PX Prídavné moduly pre R232 a R485 k integrácii zariadení z tretích (cudzích) strán PXA30-R PXA30-R1 PXA30-R2 Integrácia zariadení z tretích strán a systémov do DEIGO automatizačnej úrovne Pripojiteľné do systémovej stanice PXC00-U alebo PXC64-U a PXC128-U modulárnych automatizačných staníc Funkcie Integrácia zariadení a systémov tretích strán do BACnet automatizačnej úrovne Mapovanie a monitoring cudzích discipline ako HVAC, osvetlenie, PLC atď Prevádzkuje sa ako voľne programovateľná stanica (ako automatizačná stanica, ale bez fyzických vstupov/výstupov) pre riešenia so štandardnými a propietárnymi protokolmi Podporuje monitoring komunikácie na cudzej zbernici pomocou PX Open Monitor nástroja CM1N9281sk_02 30032007 Building Technologies

Topológia DEIGO INIGHT PXM20, PXM20-E BACnet / LON, BACnet / IP QAX PP2 PXA30-R PXC PXC-U PXC-U 9281z01 en PX-OPEN Monitor bus Third party devices / systems Typy PXA30-R PXA30-R1 PXA30-R2 Prídavný modul R232 a R485, do 100 dátových bodov Prídavný modul R232 a R485, do 400 dátových bodov Prídavný modul R232 a R485, do 2000 dátových bodov (CL: 1000 dátových bodov) Kompatibilita Modul sa vkladá do PXC00-U systémovej stanice alebo do PXC64-U alebo PXC128-U automatizačnej stanice Objednávanie Pri objednávke špecifikujte množstvo, názov produktu a typové označenie Príklad: 30 Prídavné moduly PXA30-R 2/8 Building Technologies 30032007

Mechanické vyhotovenie 9281Z02 Dvojdielne záklapné plastové telo Kryt pre ochranu kontaktov DP s elektronickými komponentami R485 prípojné svorky, 3-pólový R232 D-sub 9-pin male connector LED indikácia RX TX 9281Z06 Montáž Modul sa vkladá do PXC00-U systémovej stanice alebo do PXC64-U alebo PXC128-U automatizačnej stanice Je nevyhnutné dodržať inštrukcie dodávané s prístrojom, menovite: Nedotýkajte sa kontaktov (ED) Jemne zatlačte modul do svojej pozície (15 mm) a skontrolujte správnosť uzamknutia spoju 2 1 Zásuvná jednotka 1 4 3 2 Zadná časť 3 PXA30-R prídavný modul (vždy v pravo) 9281z02 4 Ostatné prídavné moduly (bežne PXA30-N) Poznámka: PXA30-T a PXA30-NT tiež majú D-sub 9-pin connector Tieto sú použité pre pripojenie modemu do systému DEIGO Building Technologies 30032007 3/8

Programovanie Programovanie je vykonané na nástroji DEIGO TOOLET (DT): Projekt je vytvorený pomocou YTEM DEIGN (DT-D) Kompletný projekt je exportovaný do DT-PX Vývojové prostredie K programovaniu je k dispozícii PX CL na PXC00-U, PXC64-U a PXC128-U staniciach vybavených PXA30-R prídavným modulom PXA30-R prídavné moduly nepodporujú softvérové nástroje pre vývoj iných aplikácií Tieto individuálne aplikácie musia byť vyvíjané na platforme PXE-CR Uvedenie do prevádzky na strane BACnet Uvedenie do prevádzky na automatizačnej úrovni (BACnet) sa deje pomocou nástroja DEIGO TOOLET (DT) Prístroju je pridelená adresa Do prístroja sú zavedené mapovacie tabuľky a aplikácia Adresácia Node setup cez DEIGO TOOLET Uvedenie do prevádzky na strane cudzieho zariadenia Cudzie zariadenia sú uvedené do prevádzky nástrojmi cudzích výrobcov iemens Building Technologies ponúka nástroj PX OPEN Monitor pre monitoring a analýzu toku dát na strane zbernice cudzieho systému Konektor pre tento nástroj je umiestnený na prednej strane automatizačnej stanice Likvidácia Prístroj obsahuje elektrické a elektronické prvky a nesmie sa likvidovať ako komunálny odpad Je potrebné bezpodmienečne dodržiavať platnú miestnu legislatívu 4/8 Building Technologies 30032007

Technické údaje R232 interface Použitie Cudzie zariadenia Baud rate 300, 600, 1200, 2400, 4800, 9600, 19200, 38400 (záleží na software) Data bits 7 alebo 8 (záleží na software) top bits 1 alebo 2 (záleží na software) Parity Žiadna, párna alebo nepárna (záleží na software) Flow control Xon/Xoff, hardware alebo žiadna (záleží na software) Kabeláž Typ kábla Dĺžka kábla 9-žilový štandardný tienený Max 3 m R485 interface Použitie Cudzie zariadenia (elektricky oddelené) Baud rate, data bits / stop bit(s), parity Ako u R232 (záleží na software) Kabeláž Typ kábla Dĺžka kábla Štandardný R zbernicový kábel Max 1200 m Krytie Podľa EN 60529 IP30 Trieda ochrany Trieda izolačnej triedy III Prostredie Prevádzka Class 3K5 to IEC 721 Teplota 0 50 C Vlhkosť < 85 % rh Transport Class 2K3 to IEC 721 Teplota 25 65 C Vlhkosť < 95 % rh Priemyselné štandardy Bezpečnosť produktu Elektronický automatický systém pre domáce a podobné využitie EN 60950-1 Elektromagnetická kompatibilita Odolnosť voči rušeniu EN 61000-6-2 Vyžarované rušenie EN 61000-6-2 CE marking Elektromagnetická kompatibilita 89/336/EEC Rozmery Viď Rozmery Váha s / bez balenia 75 g / 95 g Building Technologies 30032007 5/8

Pripojenie R232 serial 1 2 3 4 5 6 7 8 9 9281z04 1 DCD Data carrier detect 6 DR Data set ready 2 RXD Received data 7 RT Request to send 3 TXD Transmit data 8 CT Clear to send 4 DTR Data terminal ready 9 NC Not connected 5 GND ignal ground R485 TOP Poznámka Tienenie 9281Z05 + Tx Rx creen "" svorka nie je pripojená k DP Tienenie musí byť uzemnené v rozvádzači 9281z20 9281z21 Avoid screen pigtails! creen bus creen clamp 9281z22 upport rail 6/8 Building Technologies 30032007

Rozmery Údaje v mm 111 28 62 9281M01 33 Building Technologies 30032007 7/8

8/8 2006-2007 iemens witzerland Ltd ubject to change Building Technologies 30032007