ARC-ALERT CIRCUIT INTERRUPTER TECHNOLOGY NEXT GENERATION OF CIRCUIT PROTECTION

Similar documents
2 LABINAL POWER SYSTEMS TF300-1E

Electric Distribution & Controls. Circuit Breakers Military/Aerospace

Arc Fault Circuit Breakers Implementation

Aircraft Circuit Breaker

AP/UP, AP/MIL Series Magnetic Circuit Protectors

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59.

CH120CAFPN 1P 20A 120 Combo Arc Fault PN Breaker

CX-Series. Circuit Breaker

PD-Series Ground Fault Circuit Protection

Selection Guide. Control Circuit and Load Protection

These devices meet the requirements of OSHA 29 CFR (b)(1)(ii) and OSHA 29 CFR (a) (2)(ii)(G). Airpax LEL series

Arc Fault Circuit Interrupter (AFCI) FACT SHEET

Solid Dielectric, Three Phase Reclosers CATALOG VS11

Fighter/EW/Helo/Patrol Arc Fault Circuit Breaker Development. April 2007

FAA Aging Electrical Systems Research Program Update Prepared for: Aging Transport Systems Rulemaking Advisory Committee January 23, 2002

PERFORMANCE SPECIFICATION SHEET SWITCHES, SENSITIVE, 10 AMPERES AND LOW LEVEL, UNSEALED

MAHALAKSHMI ENGINEERING COLLEGE TIRUCHIRAPALLI

Electronic Circuit Breaker ESS20-0..

Using new Magnetically Actuated Vacuum Interrupter technology for safe and reliable medium voltage circuit breaker switching in mines

KD LV Motor Protection Relay

PERFORMANCE SPECIFICATION SHEET

PB-Series. GFCI/ELCI & Panel Seal

SURE-TRIP OEM RELACEMENT TRIP UNIT

Power systems Protection course

MAGNETIC MOTOR STARTERS

PERFORMANCE SPECIFICATION SHEET SWITCHES, SENSITIVE, SPDT, UNSEALED

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

L-Series. Circuit Breaker

Miniature circuit breaker Application guide

SURE TRIP RETRO KITS

for Critical Applications in Extreme Environments

PDR circuit breaker - Ground fault Datasheet

SURE TRIP SLT-201 SECONDARY TEST SET

Electronic Circuit Breaker ESS20

Chapter 4 Utility Systems Electrical

FR circuit breaker - hydraulic magnetic,

PORTABLE CURRENT SOURCE FOR CIRCUIT BREAKER AND MOTOR OVERLOAD TESTING INSTRUCTION MANUAL PI-250B. Release 1.0 April 5, 2013

F-Series. Circuit Breaker

The Evolution of Arc Fault Circuit Interruption

ID ID. Series 19. Mechanical Products Company

F-Series. Circuit Breaker

FR circuit breaker - hydraulic magnetic, railway, very high current. Datasheet

IAX/LUX/LEX Series Low-Depth, Hydraulic-Magnetic Circuit Breakers. Introduction Configurations Delay Curves Operating Characteristics Decision Tables

Cobra-S. Catalog Cobra-S

R series solar charger inverter 1000W to 6000W

MINIATURE POSITIVE ACTION SWITCHES MIL-S-8834 Miniature Positive Action Switches Solder Lug Terminals

New Products for Integrated Electrical Systems/Questions and Answers/Resources. necdigest. Bringing a new level of electrical protection into the home

SIRIUS 3RU2 Thermal Overload Relays

Application Description

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

TECHNICAL DATA SHEET AIRCRAFT GROUND POWER UNIT MODEL NO. B809D-1

Cutler-Hammer. Installation Instructions for the Digitrip OPTIM Pole Trip Unit Installation and Operation with L-Frame Series C Circuit Breakers

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

DETAIL SPECIFICATION SHEET SWITCHES, ROTARY, SNAP ACTION CLASS 1SR BASE MOUNTED, SIDE CONNECTED

QF(26) - Series Miniature Circuit Breakers - Low Rating (5-63 A)

UMBW-UL489 and UL1077 Listed

RESIDUAL CURRENT CIRCUIT BREAKER

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

FUSERBLOC CD. The universal Fuse Combination Switch FROM 20 TO 1250 A. Industrial Switching & Protection Systems

G-Series. Circuit Breaker.

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

BTB TYPE AUTOMATIC TRANSFER SWITCH (ATS)

CSDA Best Practice. Hi-Cycle Concrete Cutting Equipment. Effective Date: Oct 1, 2010 Revised Date:

FUEL TANK SAFETY / EWIS CONTINUATION TRAINING

PERFORMANCE SPECIFICATION SHEET SWITCHES, SENSITIVE, PLUNGER, 10 AMPERES 2PDT AND 7 AMPERES 4PDT, RESILIENT SEAL

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

ZB0050 / ZB0051 ZB0070 / ZB0071

Switches. SERIES FEATURE ACTUATION MAX RATING SEAL RATING MOUNTING CIRCUITRY 115VAC, 28VDC)

E.S.P. Embedded Sensing Probes for Motor Brushes

Series L9 UL-489 Miniature Circuit Breakers

1492-CB 1492-GH 1492-GS

HIGH POWER MOTOR TEST SYSTEMS

Mark IV Antiskid Brake Control System Upgrade. Randy Williams Crane Aerospace & Electronics

MS-Series. Circuit Breaker

DEEP SEA ELECTRONICS PLC

Ultra Fast Earthing Switch UFES retrofit Overview

INTERCONNECTION STANDARDS FOR PARALLEL OPERATION OF SMALL-SIZE GENERATING FACILITIES KILOWATTS IN THE STATE OF NEW JERSEY

Battery Control Center - Diesel

DEEP SEA ELECTRONICS PLC

Direct On Line (DOL) Motor Starter. Direct Online Motor Starter

Single Pole Circuit Protectors 67 Multi-Pole Circuit Protectors 68 Printed Circuit Board Mounting 70 Configurations 72 Operating Characteristics 73

STC SA02511SE Installation Manual & Instructions for Continued Airworthiness CC Series Fuel Level Sender

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

AR circuit breaker - Hydraulic magnetic,

WIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw

TECHNICAL DESCRIPTION

ECET Distribution System Protection. Overcurrent Protection

MGL Avionics AvioGuard. Fault protected, wide input range, isolated, DC to DC converter for avionics applications

Phenix Technologies Inc. 75 Speicher Drive Accident, Maryland 21520

QF(19) - Series Miniature Circuit Breakers

SL Series Application Notes. SL Series - Application Notes. General Application Notes. Wire Gage & Distance to Load

HI-POT/CONTINUITY TESTER Model PLEP01

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

Operator s Manual Series ATB Automatic Transfer & Bypass Isolation Switches 150, 260, and 400 amp sizes A. Rating Label.

Solid Dielectric, Single Phase Recloser

Arc Fault Circuit Breaker Development and Implementation

AeroVironment Universal Solar Pump Controllers

DETAIL SPECIFICATION SHEET

Transcription:

ARC-ALERT CIRCUIT INTERRUPTER TECHNOLOGY NEXT GENERATION OF CIRCUIT PROTECTION

ARC-ALERT CIRCUIT INTERRUPTER ARC-ALERT CIRCUIT INTERRUPTER HOW AN AEROSPACE BREAKER OPERATES HOW AN AEROSPACE BREAKER OPERATES Today, in the United States there are more than 220,000 civil and military aircraft in operation. Many are over 20 years old. To maintain air worthiness, many have been retrofitted with new engines, new avionics, improved hydraulic systems and even new interiors. However, one element in most older aircraft that will not change is the (miles and miles) of electrical wiring buried within the aging airframe. Over time these wire bundles and their protective insulation can deteriorate, providing the perfect environment for an electrical short and a potential fire hazard. Until recently, common aircraft circuit breakers, developed over 50 years ago, were considered the first line of defense. Alas, aircraft circuit breakers do not detect and react to the damage caused by the chaffing and subsequent sporadic arcing when bare wires contact metal aircraft structure or other bare conductors. When this occurs, an electrical fault, arcing can occur. Research has shown that arc faults, with temperatures as high as 6,000 C, can go completely undetected by common circuit breakers. Arc Fault Protective devices are designed to detect and react to arcing faults while allowing normal aircraft operation. In addition to the unfortunate roll call of recent aircraft accidents blamed on explosions or fires suspected to have been triggered by electrical wire arcing, the potential for additional incidents may be even more sobering. Safety reports show numerous, non-fatal incidents of smoke in the cockpit or cabin and electrical faults attributed to wire arcing. Labinal Power Systems' Patented Arc-Alert Technology The Next Generation of Circuit Protection Quick Fact: There have been 1,576 smoke or fire incidents on commercial aircraft since Jan 1984. - FAA National Aviation Safety Data Analysis Center (April 2004) Arc-fault protective technology introduces electronics to traditional circuit breakers to provide arc-fault identification and a means to trip the breaker, thereby disconnecting the affected circuit. In residential and aerospace arc-fault protective devices, Labinal Power Systems uses an independent thermal circuit breaker and adds supplementary Arc-Fault detection and Circuit Interruption (AFCI) electronics. Labinal Power Systems' design approach maintains the proven benefits of existing circuit protection while augmenting it with supplementary AFCI capability. This allows the standard circuit breaker portion of the device to operate normally until there is an arcing fault. Then, when an arcing fault occurs, the AFCI electronics actuate the trip mechanism and provide supplementary arc-fault protection. In this fashion the combination circuit breaker and arc-fault protective device will function as a conventional electro-thermal circuit breaker until an arc occurs. Maintaining the reliability of existing circuit protection while increasing the overall protection is a major accomplishment of Labinal Power Systems' implementation of AFCI circuit protection. Since 1998, Labinal Power Systems Electrical has made homes safer using Fire-Guard Circuit Protection. Labinal Power Systems has adapted this proven technology for the aerospace industry. Labinal Power Systems' Arc-Alert Circuit Interrupter technology utilizes electronics to monitor and analyze a circuit s current waveform. This logic circuit utilizes algorithms developed over the last 10 years. These algorithms look directly for the randomness in the current signal to identify an arcing event is occurring. These algorithms are able to discern between normal current signatures and arcing events due to our extensive load database validation. If the logic circuit identifies an arcing fault, it sends a signal to the circuit protection device, initiating a sequence that safely shuts down the circuit in question. Auxiliary AFCI Indicator Spring loaded temperature compensation element Spring loaded central structure and contacts SOLENOID The current aerospace circuit breaker provides simple over-current protection by utilizing a mechanical bi-metal trip mechanism. When a breaker is closed, a spring is charged and a mechanical latch holds the contacts closed. This prevents the spring from releasing. WHY A STANDARD CIRCUIT BREAKER DOESN T WORK They are not designed to detect arcing faults. Arcing fault currents are sporadic or sputtering. A serious arcing current can have an RMS heating value several times the breaker's rating. The breaker's bi-metal cannot respond fast enough to prevent the fault from cascading to other wires. The auxiliary AFCI indicator (yellow hook on top left) will only deploy if the device is actuated by the solenoid The electronics sense an arc, the Solenoid (blue) opens the device by pulling on the spring loaded temperature compensation element (purple) to the left Releasing the spring loaded central structure and contacts (gray) and opening the button If the current flowing through the bi-metal is above the circuit breaker rating for a long enough period of time, the temperature increase will cause the bi-metal element to bend toward the trip bar. This will free the latch causing the charged spring to release its energy and open the contacts, breaking the flow of power to the circuit. 2 Labinal Power Systems TF300-8H Labinal Power Systems TF300-8H 3

ARC-ALERT CIRCUIT INTERRUPTER ARC-ALERT CIRCUIT INTERRUPTER Labinal Power Systems' Arc-Alert Circuit Interrupter Enhanced Capability In The Same Package Labinal Power Systems' approach provides Form-Fit replacements with enhanced functionality by integrating Labinal Power Systems Electrical s circuitry into the standard aerospace circuit breaker. This required miniaturization of the present mechanism to make room for the necessary electronics and to provide a way to power the electronics. As a result of this effort, Labinal Power Systems' Arc-Alert Circuit Interrupter has resulted in many added benefits: Same space requirements as current circuit breakers such as MS3320 and MS14105 Separate indication of an arcing fault vs. over-current fault On-board Built-In-Test capability Power on LED indicator Redundancy. If the Arc-Alert Circuit Interrupter electronics fail, the breaker will continue to provide thermal over current protection. Nominal power draw is about 15 ma. Quick Fact: Labinal Power Systems is currently the only STC holder for the Boeing 737 series aircraft. Test Box Labinal Power Systems has developed a portable circuit breaker test box. This test box will verify the performance of installed Arc-Alert Circuit Interrupters on-board aircraft without the need to remove the breaker from the breaker panel. The test box can be used by airline maintenance crews to validate the proper operation of circuit breakers that have indicated an arcing fault. If a trip indication occurs and no damage is found upon inspection, the Arc-Alert Circuit Interrupter could be reset and connected to the test unit. The test box will verify the operation of the thermal and arc detection portions of the Arc-Alert Circuit Interrupter device. If the test box determines the device is operating properly, then the maintenance crews could "hipot" the suspected circuit This screening procedure should highlight the need for more intrusive inspection of the installed wiring. These are optional procedures intended to supplement operator s maintenance procedures. Labinal Power Systems continuously enhances Arc-Alert Test Box capabilities to provide customers with the best technology, thus the appearance may vary. Note: Financial options for Labinal Power Systems' Circuit Breaker Test Box are available to customers. Labinal Power Systems' Arc-Alert Circuit Interrupter Configurations Labinal Power Systems has developed several different AFCI configurations needed to meet customer requirements. Trip Arc-Alert Indicator Functional Indicator Labinal Power Systems adopted a mechanical AFCI trip indication to ease implementation concerns. There are three modes: arc-fault trip, thermal trip, and reset with an arc-fault trip indication. This approach allows the arc-fault protective device to be reset by the crew in the event of an arcing fault or thermal overload. However, the secondary Arc-Fault Trip Halo will remain exposed above the circuit breaker bushing and will not reset by re-closing the circuit breaker. This will assist maintenance in trouble shooting the fault and record keeping when an arcing fault has occurred. Arc Fault Thermal Fault Certification & Development Update Labinal Power Systems has been actively supporting the development of aerospace AFCI technology for over 10 years. These device have flown on numerous aircraft such as the C9, B727, B737, B747, USAF F15, USAF KC135, US Navy H60, US Navy H53, US Navy P3, US Navy F18 and small business jets. The 7000-5001 Labinal Power Systems AFCI has been awarded an STC for use on the B737 and has been qualified to AS5692/2. Pending the release of the AS5692/3 and AS5692/4 the 4310-5001 and 7000-6001 will be listed on the QPL. Several aircraft have been identified and are scheduled for further implementation of these devices. If you are interested in participating in this process, contact Labinal Power Systems' Customer Service at (941) 751-7138. Reset With Arc Fault Product Availability Pricing will vary based on order quantity and configuration. The following circuit breakers are available now: AC Single Phase (MS3320) AC single-phase (MS14105) DC single-phase (MS14105) AC Three Phase (MP1536) 4 Labinal Power Systems TF300-8H Labinal Power Systems TF300-8H 5

ARC-ALERT SINGLE POLE PERFORMANCE 4310-5001 DIMENSIONS Single-Pole High Performance The aerospace qualified product utilizes the same internal design. DIMENSIONS Performance Rated Circuit Breaker The single phase model is a sub-miniature, lightweight, trip free, circuit breaker, which combines its compact size with a solid technological track record. This model s functionality is immune to extreme fluctuations in temperature, high shock, vibration and humidity. Qualified Variants qualified to AS5692/2 Lightweight 37 grams maximum (.082 lbs.) High Interrupting Capacity High Vibration and Shock Resistance Sub-Miniature Size PERFORMANCE DATA Interrupting Capacity 1 to 20 amps 1000 amps per AS5592 at 120 V 400 Hz. AC 25-35 amps 1000 amps per AS5692 at 120 V 400 Hz. AC Endurance 2,500 cycles; rated inductive load per AS5692 paragraph 4.7.8 5,000 cycles; rated resistive load per AS5692 paragraph 4.7.8 10,000 cycles; mechanical cycling no load per AS5692 paragraph 4.7. Overload Cycling Minimum of 100 cycles at 200% rated current per AS5692 paragraph 4.7.9 Minimum of 100 cycles of Arcing detections per AS5692 paragraph 4.7.9 Dielectric Strength At sea level, 25 C, 1,500 V, AC. At 70,000 ft 71 C 500 V, AC per AS5692 paragraph 4.7.2 Insulation Resistance Not less than 100 megohms at 500 V, DC per AS5692 paragraph 4.7.3 Voltage Drop Varies with rating per AS5692 paragraph 4.7.19 (see Ordering Information ) Vibration 10G s to MIL-STD-202, Method 204, Condition A per AS5692 paragraph 4.7.11 High level sine and random vibration levels are also available Shock* Exceeds 50G s, to MIL-STD-202, Method 213, Test A per AS5692 paragraph 4.7.12 Acceleration Exceeds 10G s per AS5692 paragraph 4.7.13 *Variations of these circuit breakers are capable of exceeding the standard MIL specification for endurance, vibration, and shock. Consult your customer support engineer for more information. THERMAL OVERLOAD CALIBRATION DATA Trip Range Specification Table -55 C - 85 C 25 C 85 C -55 C 115 C Test Time Parameters Must Hold 115% 100% 115% 80% % For 1 Hour Must Trip 145% 145% 170% 145% % Within 1 Hour 200% Overload 1.5 to 50 Seconds 500% Overload 0.15 to 3.0 Seconds 1,000% Overload 0.035 to 0.8 Seconds ORDERING INFORMATION Labinal Power Systems P/N Ampere Rating Voltage Drop Max (V) 4310-5001-2.5 2 1/2 amps 0.70 4310-5001-5 5 amps 0.55 4310-5001-7.5 7 1/2 amps 0.45 4310-5001-10 10 amps 0.28 4310-5001-15 15 amps 0.25 4310-5001-20 20 amps 0.25 7000-6001-25 25 amps 0.25 7000-6001-30 30 amps 0.25 7000-6001-35 35 amps 0.25 * AT RATED NOMINAL CURRENT For other amperage ratings and configurations, consult your customer support engineer. Pricing will vary based on order quantities and configuration. THERMAL TRIP CURVE Percentage Percentage Of Circuit of Breaker s Circuit Breaker s Rated Current Rated Current 10000 1000 100 RANGE AT 25 C LOWER LIMIT AT 71 85 CC REFERENCE ONLY 10 0.001 0.01 0.1 1 10 100 1000 10000 Arc-Alert Protected Range Time To to Open (Trip) Inin Seconds UPPER LIMIT AT -40-55 CC REFERENCE ONLY TYPICAL TRIP CURVE AT 25 C 160% 170% 138% 145% 115% 100% 6 Labinal Power Systems TF300-8H Labinal Power Systems TF300-8H 7

LABINAL POWER SYSTEMS Headquarters : 36 rue Raymond Grimaud 31700 BLAGNAC - FRANCE Tél. +33 (0)5 34 60 00 00 - Fax +33 (0)5 34 60 01 99 www.labinal-power.com