Electrical Safety and Reliability: Short-Circuit Current Rating (SCCR) Equipment SCCR made easy

Similar documents
HVAC and Refrigeration Circuit Protection Solutions. Compact and safe HVAC/R circuit protection

Electrical safety and reliability: Selective coordination. Protect with selective coordination

Simplified Guide To Understanding Short-Circuit Current Rating FIND IT, FIX IT, FORGET IT

A case study in solving SCCR issues

Advanced Guide To Understanding Assembly Short-Circuit Current Rating WITH ENGINEERING SOLUTIONS AND OVERCURRENT PROTECTION DEVICES TO ENHANCE SCCR

The easiest and fastest way to select and specify the right control circuit fuse

The easiest and fastest way to select and specify the right fuse

Compact Circuit Protector (CCP) Application Note

Medium Voltage Fuses. Industry s most comprehensive medium voltage circuit protection

Devices for Branch Circuits and Feeders

Current Ratings. Standards & codes note 1. Introduction. interest. By Steve Hansen Sr. Field Engineer

Selective Coordination Enforcement:

Electrical Safety and Overcurrent Protection

Now - Up To 400A Mains!

Low Voltage Fuses For Motor Protection

Selection Guide Motor Control Device Solutions

Application note Compact Circuit Protector (CCP2) Smaller, better... the Power of Space

Downtime Reduction, Workplace Safety & Code Compliance SERVICES TO INCREASE YOUR PRODUCTIVITY THROUGH PROTECTION

Understanding National Electric Code (NEC) tap rules How do they apply to circuit breaker terminals?

Products for enhancing electrical safety and reliability

Compact Circuit Protector (CCP)

Selection Guide. Control Circuit and Load Protection

Compact Circuit Protector (CCP)

Specification made simple for selective coordination in a compact size

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

CUBEFuse. CUBEFuse catalog numbers (amps)

Bussmann series Quik-Spec Coordination Panelboard

PowerPact B. Molded case circuit breakers and switches from A

Design Standards NEMA

Arc flash solutions catalogue Australia. Safety solutions - Protecting employees and the enterprise

Suggestion on How to Use

BRANCH CIRCUIT PROTECTION FUSED COORDINATION PANELBOARD

TECHNICAL WHITE PAPER

Bussmann series NH catalogue. Leadership in circuit protection

Powering business worldwide

Selecting Protective Devices

What's New with UL508A Codes & Standards Presented by Jeff Woolfolk Manufacturing in America March 14-15, 2018

Fused Coordination Panelboard

XIRIA Green, Smart, Compact solution

Eaton Corporation An Overview Eaton Corporation. All rights reserved.

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x.

Overcurrent Protection According to the 2011 NEC

Selective Coordination Requirements

Fuseology. Dual-Element, Time-Delay Fuse Operation

Design Considerations to Enhance Safety and Reliability for Service Entrance Switchboards

Electric vehicle auxiliary fuses 500 Vdc, A

Quik-Spec Coordination Panelboard Specifications

Enclosed Full-Voltage Starters

6.3 mm reverse quick connect

Effective December 2015 Supersedes September 2013

Quick Start Guide TS 910 & TS 920

BUSSMANN. CUBEFuse Compact Circuit Protector Base (CCPB) SERIES. Technical Data Effective April 2017 Supersedes April 2016

ACHIEVING MAXIMUM BENEFITS WITH A FUSE PROTECTED MOTOR CONTROL CENTER

Compact Circuit Protector

Capabilities Brochure

Quick Start Guide TS 910

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

MOLDED CASE CIRCUIT BREAKER BASICS. David Castor, P.E.

Enclosed Full-Voltage Starters

XT IEC Power Control Manual Motor Protectors

Miniature circuit breaker Application guide

Recommended Procedures

W-SLC Medium Voltage fused contactor truck A safe, reliable and efficient motor starter

Up to 60 A Class R 250 V and 600 V ferrule power distribution fuse blocks

W-VACi MV circuit breakers

YOUR ELECTRICAL SYSTEM IS YOUR LIFELINE AMP-TRAP 2000 FUSES

Service Entrance Methods

Bussmann series Traction fuse links catalogue. Fuse links for railway applications

Quik-Spec Electrical Gear

Low-Peak 600V Class RK1

Short-Circuit Current Rating - SCCR Watlow Power Controllers

Leadership in Circuit Protection

Managing Electric Vehicle Supply Equipment (EVSE) Installations

MP-4000 Motor Protection

Compact Circuit Protector (CCP)

Industry s most comprehensive medium voltage circuit protection

Fused Coordination Panelboard

NEC REQUIREMENTS FOR GENERATORS

Busway. Siemens STEP 2000 Course. STEP 2000 Courses distributed by

ECET Distribution System Protection. Overcurrent Protection

Compact Circuit Protector (CCP)

GE Energy Industrial Solutions. EV Charging Station. Application Guide. imagination at work

DER Commissioning Guidelines Community Scale PV Generation Interconnected Using Xcel Energy s Minnesota Section 10 Tariff Version 1.

BUSSMANN. Pre-production and sample electric vehicle power fuses 500 Vdc, A SERIES. Technical Data Effective December 2018.

Receptacles & Wall Boxes

MAGNETIC MOTOR STARTERS

Fuseology. Fuse Holders, Fuse Blocks, Power Distribution Blocks & Surge Suppression. Optima Fuse Holders & Overcurrent Protection Modules.

ECET Circuit Design Motor Loads. Branch Circuits. Article 210

the safe, reliable, and efficient choice for MV switchgear

Multi-Pak Group Control

Autodesk Inc. CB (Circuit Breakers): Following series contents are added/updated. CR (Control Relays) Following series contents are added.

Installation and Construction Notes for EVSE4

Leadership in Circuit Protection

Product Guide. enclosed NEMA STARTERS

Applying Interrupting Rating: Circuit Breakers

6/4/2017. Advances in technology to address safety. Thomas A. Domitrovich, P.E., LEED AP VP, Technical Sales Eaton

Applying Interrupting Rating: Circuit Breakers

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw

Quik-Spec Coordination Panelboard

Transcription:

Electrical Safety and Reliability: Short-Circuit Current Rating (SCCR) Equipment SCCR made easy

Case study A Wisconsin-based manufacturer of chiller equipment needed to improve the SCCR of their standard design from 5,000 amps to 85,000 amps in order to meet a customer requirement. Struggling with the task, they reached out to a local Eaton application engineer for support. The goal was to develop a solution with minimal changes to material costs and minimal engineering effort. After working closely with our team, the customer quickly achieved a solution that involved minimal component changes and was in line with the original material costs. The customer now has the tools and support needed to efficiently meet the code requirements regarding equipment SCCR as well as provide equipment that assists their customers toward providing a safe working environment.

Is your system safe? A short-circuit current rating (SCCR) represents the maximum level of fault current that the control panel or machinery can safely withstand. The NEC requires that industrial control panels, industrial machinery and HVAC equipment be marked with an assembly SCCR that is greater than the fault current at the location where the equipment is installed. Inspectors and installers need this information in order to ensure compliance with NEC 110.10. Adequate SCCR is imperative for a safe electrical system. If the available fault current of the system exceeds the equipment SCCR and a short-circuit occurs, catastrophic damage to the panel may occur. Electrical workers and others are put at risk of injury from burns, flying debris and electric shock. Nearby equipment is also at risk of damage and the improperly installed piece of equipment can cause fines or commissioning delays. To help ensure a safe system, personnel and equipment, SCCRs must be properly understood and implemented. Protecting what matters most With safety and compliance top priority, both users and manufacturers of equipment play a key role in understanding and implementing adequate SCCRs. For users of machinery equipment, understanding the available fault current at the location where equipment is installed is a key first step to providing adequate SCCR protection requirements. Users should communicate these requirements to their equipment suppliers and verify equipment installed meets those requirements. This enhances the safety of the system, but also builds flexibility into the equipment for the customer. For the original equipment manufacturer (OEM), determining and marking the assembly SCCR on the equipment provides important SCCR information to the authority having jurisdiction. This is a critical element to allow for proper installation, but also can provide a competitive advantage. In a recent survey, more than half of OEMs surveyed expressed some degree of difficulty locating SCCRs for components needed to design an SCCR solution. Nearly half also stated that they have difficulty applying or interpreting the standard that determines panel SCCR. Whether you re determining how much SCCR protection is needed, or determining the SCCR of your equipment control panel, the process does not have to be a struggle. When you partner with Eaton, you gain access to a range of products and solutions that make SCCR compliance easy and efficient. We offer software solutions that: Quickly determine available fault current Quickly display component SCCR solutions Quickly determine the SCCR of a control panel Each of these solutions takes the difficulty and guesswork out of the equation. In addition to these tools, we have the right product portfolio that: Offers the largest product offering, from fuses and circuit breakers to power distribution blocks, terminal blocks and control equipment. Meets a wide range of SCCR needs 300kA. Limits and lowers fault current. Additionally, Eaton's Electrical Engineering Services and Systems team offers a comprehensive portfolio of services tailored for every stage of a power system s life cycle-including fault current and arc flash studies. Visit www.eaton.com/sccr for more information on how Eaton can help ensure that you re protecting what matters most. www.eaton.com 3

Software application solutions Eaton offers three application solutions that make SCCR compliance easy and efficient. From the available fault current of the incoming power to both component and panel SCCR, these applications guide you through the process of determining an efficient and safe SCCR solution. 4 www.eaton.com

FC 2 mobile app Easily calculates available fault current anytime, anywhere Easily calculate Eaton s FC 2 mobile app quickly delivers fault current calculations in the palm of your hand. The program: Calculates both three-phase and single-phase faults Creates and emails NEC compliant labels and one-line diagrams Includes a comprehensive user guide Features a fuse sizing guide for main, feeder and branch circuits FC 2 considers transformer size, conductors and conduit in calculating the fault current. For more information, visit www. bussmann.com and search for FC2. SCCR Protection Suite Quickly finds components with the SCCRs you need Validate and sustain Quickly find With just a few simple selections from drop-down lists, you can easily find all the available Eaton components and their respective SCCRs based on your system needs. You can reduce the number of results by setting various component preferences. SCCR Protection Suite also allows the application of an upstream current limiting device to determine if the branch circuit SCCR can be raised. To access SCCR Protection Suite, go to www.eaton.com/sccr. OSCAR 2.1 Calculates and documents assembly SCCR for a control panel Eaton s OSCAR software allows you to enter a one-line diagram of a control panel circuit, identify the components in that circuit and calculate the SCCR for the entire assembly. OSCAR contains over 60,000 part numbers and thousands of component SCCRs. The program also applies current limiting rules per UL508A that permit the SCCR of branch circuits to be raised. What s more, you can view, print and save SCCR analysis reports. For more information, please go to oscar.eaton.com. www.eaton.com 5

Product solutions When developing a panel with a desired SCCR level, one of the most difficult challenges is resolving the SCCR weak links in the panel circuit. These weak links are components in the panel that do not have sufficient component SCCR, and thus lower the panel assembly short-circuit current rating. Eaton offers a comprehensive product portfolio that ranges from fuses and circuit breakers to power distribution blocks, terminal blocks and control equipment that meets a broad range of SCCRs, from 18kA to 200kA. These solutions eliminate weak links by raising the component SCCR, limiting the fault current or lowering the fault current. The tables below represent common SCCR weak links that can limit the overall assembly SCCR, and a selection of Eaton solutions and the level of protection they can provide. Visit www.eaton.com/sccr to find specific part numbers for the solutions mentioned below. CHALLENGE SOLUTION Component type Miniature fuses Miniature circuit breaker Supplementary protector Fuseholders Switches Power distribution Motor starters Default SCCR protection 0.2kA Eaton solution Basic 18kA Mid 3 SCCR protection level High 6 Premium 100kA Ultimate 200kA Fuses - Class CC, CF, J, R, T Circuit breakers - Series G, C Fuses - Class CC, CF, J, R, T Circuit breakers - Series G, C Fuses - Class CC, CF, J, R, T Circuit breakers - Series G, C Fuse holder with Class CC, CF, J, R, T fuse RDF fusible switches with fuse RD UL 508 and 98 non-fused switches with fuse Compact Circuit Protector (CCP) with fuse PDB and PDBFS power distribution blocks with fuse PDB and PDBFS power distribution blocks with breaker a a a Power distribution fuse blocks with fuse Multi-wire lugs on circuit breakers XT IEC with fuse * XT IEC with breaker a a a a* a* XT IEC with motor circuit protector a a a a XT IEC Type E/F a a a Freedom NEMA with fuse * Freedom NEMA with breaker * Freedom NEMA with motor circuit protector a a a a A25 definite purpose (to 75A) with fuse * XT manual starters Type E/F a a a 6 www.eaton.com

CHALLENGE SOLUTION Component type Default SCCR protection Eaton solution Basic 18kA Mid 3 SCCR protection level High 6 Premium 100kA Ultimate 200kA Motor overload protection Reduced voltage motor starters Adjustable frequency drive Resistor/noninductive loads Lighting controllers Ground fault and current monitoring relays Terminal blocks High fault currents larger than panel SCCR XT Electronic with fuse * XT Electronic with breaker * C441 motor insight with fuse * C441 motor insight with breaker * S801/S811+, S611 with fuse * S801/S811+, S611 with breaker * S801/S811+, S611 with motor circuit protector a a a a DA1, DC1, DE1, DG1, MMX, SVX, SPX with fuse * DA1, DC1, DE1, DG1, MMX, SVX, SPX with breaker * XT IEC with fuse * XT IEC with breaker a a a a* a* Freedom NEMA XT NEMA with fuse * Freedom NEMA XT NEMA with breaker * C25 definite purpose (to 75A) with fuse * A202 lighting with fuse * A202 lighting with breaker * CT Type CurrentWatch sensors CT Type D65 relays DP and DG terminal blocks with fuse Control power transformers** Encapsulated transformers** Dry type transformers** External disconnect with current limiting fuses** Current limiting circuit breakers** * SCCR applies to devices in the branch circuit with a properly applied upstream current-limiting overcurrent protective device in the feeder. See SCCR Protection Suite for specific part number solutions. ** Lowered fault current or raised SCCR with properly applied current limiting devices and transformers. See UL 508A regarding proper application. www.eaton.com 7

Leadership in circuit protection At Eaton, we re energized by the challenge of powering a world that demands more. With over 100 years of experience in electrical power management, we have the expertise to see beyond today. Eaton s electrical business offers end-to-end solutions to better: Meet the demands of new construction projects Modernize aging infrastructure Manage energy consumption Protect people, equipment and data We work closely with our customers to understand and solve the challenges they face today and those that come tomorrow. Our proven technologies increase productivity, reduce energy consumption and help us all build a more sustainable world. At Eaton, that s how we re powering business worldwide. Eaton Electrical Sector 1000 Cherrington Pkwy Moon Township, PA 15108 United States www.eaton.com Eaton s Bussmann Business 114 Old State Road Ellisville, MO 63021 United States www.bussmann.com 2015 Eaton All Rights Reserved Printed in USA Publication No. 10374 March 2015 Want to learn more? Visit us at: www.eaton.com/machinebuilding www.eaton.com/ul508a