Mounting SySteMS ApplicAtionS overview version 1.2 March 2013

Similar documents
S:FLEX PRODUCTS Photovoltaic Mounting Systems. Product catalogue

TRI STAND East-West for flat roofs

Schletter. Solar Mounting Systems

Installation Manual. Logasol SKS 4.0 Mounting on sloped roofs. Flat Plate Collectors. For Contractors. Please read carefully prior to installation.

FKB-1 / FKC /200/300 l system. Thermosiphon for flat roofs and rooftops. Installation instructions (2010/06) GR

Mounting System Photovoltaic MSP system

OV-1 STANDING SEAM OVERVIEW. Temple Architectural Products 638 Moore Rd Avon Lake, OH 44012

Manual CPK 7210 N. Flate plate collector. Mounting parallel bench srew mountingsystem x x x x / version

PRODUCT EVALUATION Effective Date: July 1, 2014 RC-20

Installation and Operation Manual for a Solar System with KPW Collectors

Installation instructions

Installation instructions

PRODUCTS FOR PV SOLAR MOUNTING APPLICATIONS ROOF MOUNT SYSTEMS...3. GROUND and pole MOUNT SYSTEMS...5. L Feet...9. Corrugated/IBR Roof Mounts...

VIESMANN. Installation instructions VITOSOL 200-T. for contractors. Vitosol 200-T Type SP2 Vacuum tube collector based on the heat pipe principle

Solar. Solar collectors

3.0 RAIL-FREE RACKING. Utilizes EcoFasten Solar s patented technology

4.0 RAIL-FREE RACKING. Utilizes EcoFasten Solar s patented technology

MAJESTIC SLATE ECOSTAR GOLD STAR ROOF SYSTEM

SOLAR-LIFESTYLE INSTALLATION AND MAINTENANCE INSTRUCTIONS FLAT-PLATE COLLECTOR FLAT ROOF AND WALL-MOUNTED INSTALLATION (2011/05) UK

SOLAR-LUX 6/12 INSTALLATION AND MAINTENANCE INSTRUCTIONS EVACUATED TUBE COLLECTOR ROOF MOUNTING INSTALLATION UK/IE (2011/05) GB/IE

Pressure Sensitive Seam Tape Features 30.5m long rolls or sold by the metre (can be sold by 10th of metre). Must be used with an EPDM primer.

Bolt FBN The heavyweight.

Conveyors 12. slide strips roller Conveyors roller elements Conveyor rollers Chain Transfer

Component Catalogue Product Family SOE

Installation and Operation Manual for a Solar System with KPC1-BP Collectors

GUIDANCE NOTES. Solar Collectors. On-Roof Installation (First Fix) Please leave these instructions with the User. Baxi Heating UK Ltd 2012

L-SERIES CLUTCHES L-SERIES CLUTCHES. Getting Started INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS

SERIES W50 TECHNICAL CATALOGUE

MANUAL. Collector FK7300. Mounting parallel roof bracket attachment system

Fitting instructions for all. SitaAttika roof outlets and accessoires

FS II - Mounting Instruction. 1 General 2. 2 Pile driving (Ramming) 3. 3 Mounting individual assemblies 4. 4 Components list 5

argco.com

Commercial Hopper Tanks (CHT)

Installation, operating and maintenance instructions

WOOD FIRE FLUE KIT AND ACCESSORIES MANUAL

for Solar Systems with KTU R Collectors

Mounting System Photovoltaic MSP system

Play it safe. Mounting instructions incell system. Premium incell XM, L Mounting system for roof-integrated photovoltaic systems

REGULATED VENTILATION FOR LIFT SHAFTS SIMPLE AND EFFICIENT BLUEKIT VENTILATION FLAPS EFFICIENCY

Anchor bolt FAZ II Millionfold proven anchor bolt and the strongest in its class.

Installation. Storage. Tools

SHELVING PRODUCTS. Maximize Your Storage Space

SENECA SHAKE TILES ECOSTAR GOLD STAR ROOF SYSTEM

Flat-roof system Windsafe

PV-ezRack SolarTerrace III-A Installation Guide V1.4

MAJESTIC NIAGARA SLATE ECOSTAR GOLD STAR ROOF SYSTEM

VIESMANN. Installation instructions VITOSOL 300-T. for contractors. Vitosol 300-T Type SP3A Vacuum tube collector based on the heat pipe principle

Volkswagen New Beetle Body - Exterior 64 Glass, Window regulators (Page GR-64)

MAJESTIC SLATE CLASS A ECOSTAR GOLD STAR ROOF SYSTEM SPECIFICATIONS

Operations and Assembly Manual

LYSAGHT SELECT SEAM Series

fischer Bolt anchor FAZ II

Current Automation Catalogue Page 219. Fronius

2002 Convertible Cloth Sleeve Convertible Cloth Attachment

2.0 RAIL FREE SOLAR ROOF MOUNT. Utilizes EcoFasten Solar s patented technology

Installation Lexan Panel Pulley Driven Lifting System

Sunroof / Moonroof: Service and Repair Repair Procedures

Installation Instructions

THE NEW TS IT RACK 8

VIESMANN. Installation instructions VITOSOL-F. for contractors

Components, Mounting Systems, In-roof PV Solutions FATH Solar About us Page 3

Quality by Design CAPACITIES FROM 75,000 TO OVER 750,000 BUSHELS VARIETY OF PEAK LOAD RATINGS LARGE ROOF DECKS

The GK units differ from the LK units in that the springs of the GK units have a spring eye at the front.

Befestigungssysteme Klimatechnisches Zubehör. Fixing systems

5 Mechanisms and accessories

MAJESTIC SLATE ECOSTAR GOLD STAR ROOF SYSTEM

Introduction to Solar PV. Basics

access

KROFTMAN CONTAINER SHELTER TC812

insulated sectional 2180mm (h) x 2550mm (w) Opening Size: 2140mm (h) x 2500mm (w) suits single car garage

MÜPRO. One-piece pipe clamps. Sprinkler pipe clamps. Refrigerant pipe clamps. Two-piece pipe clamps. Heavy-duty pipe support/din pipe clamps

METAL BUILDING AND STANDING SEAM COMPONENTS

3-Phase Motor Demo. R Hoadley 10 Oct 2009

Tecstrut Channel Suspension & Framing System

EN Vario Curtain Sider Roof. Assembly instructions.

PV on flatroofs - fast and easy. made in Germany

Cordless rotary hammer drill 18,0 V CHE 18.0-EC

STATE OF NORTH CAROLINA D DEPARTMENT OF ADMINISTRATION MARCH 20, 1995 PURCHASE AND CONTRACT DIVISION 7125-LM-2C November 9, 1989

NEW RESIDENCE - Sample Takeoff UpState Estimating / Material Takeoff

The specialist for fastening technology. Post holders NEW. to our product range

Modul-System SMART AND VERSATILE MULTI-BOX

By CNP INDUSTRIES, INC. P.O. Box Anaheim, Ca (877)

BAVONA TP6500 HARDTOP

technical sheet RAILSCAF horizontal monorail access system

Function: Used to connect profiles at adjustable angles. Features: 1. Adjustable angles. Item Description For Screw Weight (g) Colour Finish Material

INSTALLATION INSTRUCTIONS

Sunbeam Nova. Installation guide. Universal. Symmetrical THE PROFESSIONAL PV MOUNTING SYSTEM

INSTALLATION FIXED CANVAS TS100 PULLEY DRIVEN LIFTING SYSTEM

Cordless angle grinder ACCUFLEX 18.0 V, 125 mm. L EC/5.0 Set

TRIC A On-Roof Installation for EURO- Collectors*

OPERATION MANUAL NT50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 7/11 rev. 1

Original operating instructions. Transit silo. Model. Transit silo

Slim profile steel system for doors and windows

PATIO AWNINGS HAROL VZ520 TECHNICAL INFORMATION

Bolter Miner ABM Technical Description

Guangzhou Stadium Project TRADITIONAL

SKYFORCE. Max. width up to 3000 mm Suitable for plastic, aluminium and wooden frames Mounting on stone, concrete and steel

9'8" x 9'8" (8,8 m2)

M-5230-V6 Mustang V6 Dual Exhaust Kit INSTRUCTION SHEET

UniRac. 28 MOUNTING STRUCTURES Roof Mounts. SolarMount

Transcription:

Mounting Systems Applications Overview Version 1.2 March 2013

tritec Mounting Systems: Applications Overview I. Pitched Roof: Roof-Top 1. Tiles, shingles and corrugated panels 1.1 TRI-STAND on tiles 1.1.1 Insertion system 1.1.2 Clip system 1.2 TRI-STAND on shingles 1.3 TRI-STAND on corrugated panel roofs 2. Trapezoidal sheet metal roof 2.1 TRI-VENT 2.1.1 Horizontal installation 2.1.2 Vertical installation 2.2 TRI-STAND 2.2.1 Insertion system with rivet SafeClick 2.2.2 Clip system with rivet SafeClick 2.3 TRI-STAND Aero Special Solution 2.3.1 Mounted transversely to UP-TS profiles 2.3.2 Mounted lengthwise to UP-TS profiles 3. Sheet metal roof 3.1 TRI-STAND 3.1.1 Insertion system on sheet metal clips 3.1.2 Clip system on sheet meal clips 3.2 TRI-STAND Aero Special Solution 3.2.1 Mounted on clamps for sheet metal transversely to UP-TS profiles 3.2.2 Mounted on clamps for sheet metal lengthwise to UP-TS profiles II. Pitched Roof elevation 1. TRI-STAND triangle installation with insertion system 1.1 Fastening with roof hooks 1.2 Fastening with hanger bolts 2. TRI-STAND triangle installation with clip system Special Solution 2.1 Fastening with roof hooks 2.2 Fastening with hanger bolts III. Pitched Roof: Roof Integrated 1. TRI-ROOF on wooden purlins 2. TRI-ROOF on steel purlins 3. TRI-ROOF on tile battening IV. Flat Roof 1. Flat roof with low load capacity 1.1 TRI-STAND Aero 1.2 TRI-STAND east-west support 2. Flat roof with normal load capacity 2.1 TRI-STAND triangle installation 2.1.1 Insertion system 2.1.2 Clip system Special Solution 2.2 TRI-STAND upright installation 2.2.1 Insertion system 2.2.2 Clip system Special Solution V. Facade 1. TRI-STAND vertical installation 2. TRI-STAND inclined installation

I. Pitched-Roof: Roof-Top 1. Tiles, shingles, corrugated panels 1.1 TRI-STAND on tiles 1.1.1 Insertion system 35.7 (module + 11.5 mm) * number of modules + 69 mm 69 module - 57.5 mm 69 module - 57.5 mm 69 module 8.5 3 module 11.5 33.3 TS profile PV module PV module UP-L, UP or UP-S module + 11.5 mm for standard tiles for flat beaver tail tiles for shingles and slate Insertion system time-saving no-screw module installation easy removal of modules for replacement or maintenance work no clip marks optimum load distribution different profile gauges for both light-weight designs and statically optimized constructions one or several roof hook variants for virtually any application optionally black profiles for visually attractive systems with black modules horizontal and vertical module installation UP-C / TS-C profile TS insertion profile TS central rail roof hooks TS edging tool for high static loads connector secure connection of profiles insertion profile for standard frame heights additional reinforcement for vertical module insertion and a pressure load assumption of over 2,400 N/m 2 variable or fixed depending on type of tiles for edge-trimming the profiles For the insertion system, please comply with the module manufacturer s instructions.

I. Pitched-Roof: Roof-Top 1. Tiles, shingles, corrugated panels 1.1 TRI-STAND on tiles 1.1.2 Clip system UP-L, UP or UP-S PV module PV module for standard tiles for flat beaver tail tiles for shingles for large rafter spacings Clip system materials-saving manufacturer-conforming mode of installation low system costs per kwp standard on the European market for large rafter spacings since, by clipping, the module supports the system statics. different profile gauges for both light-weight designs and statically optimized constructions one or several roof hook variants for virtually any application optionally black profiles for visually attractive systems with black modules horizontal and vertical module installation UP-C profile connector roof hooks variable or fixed for high static loads secure connection of profiles depending on type of tiles

I. Pitched-Roof: Roof-Top 1. Tiles, shingles, corrugated panels 1.2 TRI-STAND on shingles (module + 11.5 mm) * number of modules + 69 mm 69 module - 57.5 mm 69 module - 57.5 mm 69 35.7 module 8.5 3 module 11.5 33.3 TS profile PV module PV module On all types of shingle roofs with hanger bolts To be taken into account here: Fastening of counter-battening (min. 45/45 mm) must be able to withstand the additional loads. Set screws must be centrically set into the counter-battening. Asbestos-containing roof shingles may not be worked on. Module installation Insertion system: optimum load distribution and time-saving no-screw installation Clip system: materials-saving mode of installation and low system costs per kwp different profile gauges for both light-weight designs and statically optimized constructions optionally black profiles for visually attractive systems with black modules horizontal and vertical module installation no quality impairment of the subroof due to fastening screws in counter-battening UP-C / TS-C profile connector hanger bolts TS central rail TS edging tool for high static loads secure connection of profiles specifically for fiber cement shingles specifically for fiber cement shingles for edge-trimming the profiles For the insertion system, please comply with the module manufacturer s instructions.

I. Pitched-Roof: Roof-Top 1. Tiles, shingles, corrugated panels 1.3 TRI-STAND on corrugated panel roofs (module + 11.5 mm) * number of modules + 69 mm 69 69 module - 57.5 mm 69 module - 57.5 mm 35.7 module 8.5 3 module 11.5 33.3 TS profile PV module UP-L, UP or UP-S PV module for all types of pitched roofs with profiled or corrugated surfaces for corrugated panels for corrugated fiber cement panels Module installation Insertion system: optimum load distribution and time-saving no-screw installation Clip system: materials-saving mode of installation and low system costs per kwp optionally black profiles for visually attractive systems with black modules different profile gauges for both light-weight designs and statically optimized constructions horizontal and vertical module installation freely selectable degree of rear ventilation by means of different hanger bolt sizes solid fastening even for comparatively thick and soft insulation layers for high static loads UP-C / TS-C profile connector secure connection of profiles hanger bolts in different sizes (M8, M10, M12) TS central rail possibly required for insertion system TS edging tool for edge-trimming the profiles For the insertion system, please comply with the module manufacturer s instructions.

I. Pitched-Roof: Roof-Top 2. Trapezoidal sheet metal roof 2.1 TRI-VENT 2.1.1 Horizontal installation (width of module + 20) * number of modules - 20 (in mm) width of module 20 width of module 20 20 width of module on trapezoidal sheet metal roofs on sandwich elements applicable at all bead spacings between 90 and 350 mm due to carrier profiles of different lengths Installation riveting instead of bolting carrier profiles for higher loads up to 2400 N/m 2 low cost and uncomplicated shipment thanks to few components no consequences due to heat expansion: modules are set on short rails, tension-free and without clipping suitable for virtually any trapezoidal sheet metal roof and modules of different frame thicknesses TRI-DESIGN software for optimum, standard planning and dimensioning of the system central and end module anchor each applicable for two different module widths carrier profile available in different lengths sealing rivets for fastening the carrier profiles drilling gauge for optimum alignment of drill holes TRI-VENT bending tool for secure fixation of end module anchors

I. Pitched-Roof: Roof-Top 2. Trapezoidal sheet metal roof 2.1 TRI-VENT 2.1.2 Vertical installation (length of module + 20) * number of modules - 20 (in mm) length of module 20 lower installation hole spacing installation hole spacing lower instal. upper instal. upper installation hole spacing 20 on trapezoidal sheet metal roofs on sandwich elements applicable at all bead spacings between 90 and 350 mm due to carrier profiles of different lengths Installation riveting instead of bolting carrier profiles for higher loads up to 2400 N/m 2 low cost and uncomplicated shipment thanks to few components no consequences due to heat expansion: modules are set on short rails, tension-free and without clipping no slipping of modules due to circlips suitable for virtually any trapezoidal sheet metal roof and modules of different frame thicknesses central and end module anchor each applicable for two different module widths carrier profile available in different lengths sealing rivets for fastening the carrier profiles drilling gauge for optimum alignment of drill holes circlips 2 pieces per module, suitable for all framed modules TRI-VENT bending tool for secure fixation of end module anchors

I. Pitched-Roof: Roof-Top 2. Trapezoidal sheet metal roof 2.2 TRI-STAND 2.2.1 Insertion system with rivet SafeClick height of module field = (length of module insertion + 11.5 mm) * number of modules + 69 mm drilling hole spacing = length of module insertion + 11.5 mm) on trapezoidal sheet metal roofs on sandwich elements Insertion system time-saving no-screw module installation easy removal of modules for replacement or maintenance work to clip marks optimum load distribution Installation quick and easy since only one setting is required for the drilling gauge module load possible up to 5400 N/m 2 location-optimized load distribution to all outward beads thanks to continuous rails horizontal and vertical module installation Number of rivet SafeClick is selected depending on roof load, bead space, trapezoidal sheet metal gauge and material (aluminium or steel). TS profile TS-M central rail rivet SafeClick drilling gauge rubber seal and rivet TS edging tool in aluminium or black for TRI-STAND insertion profiles quick and stable joining of SafeClick connections for optimum calibration of drill holes for optimum impermeability of the roof for edge-trimming the profiles

I. Pitched-Roof: Roof-Top 2. Trapezoidal sheet metal roof 2.2 TRI-STAND 2.2.1 Clip system with rivet SafeClick length of module / 5 length of module length of module * 0.6 (length of module + 20) * number of modules - 20 (in mm) 20 length of module / 5 * 2 + 20 (in mm) length of module / 5 20 length of module / 5 length of module / 5 on trapezoidal sheet metal roofs on sandwich elements Clip system materials-saving manufacturer-conforming mode of installation low system costs per kwp standard on the European market Installation vertical module installation module load possible up to 5400 N/m 2 location-optimized load distribution to all outward beads thanks to continuous rails In case of interfering objects, the position of a UP-TS profile may be slightly changed without displacement of the entire module field. Number of rivet SafeClick is selected depending on roof load, bead space trapezoidal sheet metal gauge. center clips UP-TS profile rivet SafeClick drilling gauge in aluminium or black carrier profile for modules quick and stable joining of SafeClick connections for optimum calibration of drill holes

I. Pitched-Roof: Roof-Top 2. Trapezoidal sheet metal roof 2.3 TRI-STAND Aero 2.3.1 Mounted on clamps for sheet metal transversely to UP-TS profiles for module widths 790-810 mm and 990-1010 mm shading angle V2A drilling screw 6.3 x 40 (Aero 80) 859 mm, Aero 100) 1062 mm (Aero 80) 859 mm, Aero 100) 1062 mm calculation as a function of the shading angle V2A drilling screw 6.3 x 40 hexagonal screw M10x25 A2 sliding nut M10 SafeClick UP-TS profile hexagonal screw M10x25 A2 sliding nut M10 SafeClick UP-TS profile Support directly on pitched trapezoidal sheet metal roofs with a southern orientation by means of SafeClick Module installation cost benefit due to fast installation and low materials expenditure, generally without additional weighting manufacturer-conforming module installation at installation drill holes allows module loads of up to 5,400 N/m 2 Mounting system suitable for all standard modules of a width of 790 to 810 mm and 990 to 1010 mm reduced dynamic and wind pressure load due to wind baffle fixed 20 angle: Reduction of shading clearances and thus higher performance per m 2 and tested in the wind tunnel UP-TS profile TS-F angle wind baffle UP-C universal profile SafeClick universal profile for SafeClick connection with reinforcement and guide ribs for stable installation in two standard designs connector if necessary for the connection of continuous rails

I. Pitched-Roof: Roof-Top 2. Trapezoidal sheet metal roof 2.3 TRI-STAND Aero 2.3.2 Mounted on clamps for sheet metal lenghtwise to UP-TS profiles for modue widths 790 810 mm and 990 1010 shading angle Calculation as a function of the shading angle hexagonal screw M10x25 A2 sliding nut M10 UP-TS profile hexagonal screw M10x25 A2 sliding nut M10 UP-TS profile rubber seal drilling screw V2A 6.3x40 sealing rivets two alternatives to fix wind baffle plate special SafeClick vis à tête hexagonale M10x25 A2 self locking nut M10 Support directly on pitched trapezoidal sheet metal roofs with a east/west orientation by means of SafeClick Module installation cost benefit due to fast installation and low materials expenditure, generally without additional weighting manufacturer-conforming module installation at installation drill holes allows module loads of up to 5,400 N/m 2 Mounting system suitable for all standard modules of a width of 790 to 810 mm and 990 to 1010 mm reduced dynamic and wind pressure load due to wind baffle fixed 20 angle: Reduction of shading clearances and thus higher performance per m 2 and tested in the wind tunnel UP-TS profile TS-F angle wind baffle UP-C universal profile SafeClick material optimised profile universal profile for SafeClick connection with reinforcement and guide ribs for stable installation in two standard designs connector if necessary for the connection of continuous rails

I. Pitched-Roof: Roof-Top 3. Sheet metal roof 3.1 TRI-STAND 3.1.1 Insertion system on sheet metal clips height of module field = (length of module insertion + 11.5 mm) * number of modules + 69 mm 6.9 module - 57.5 mm 6.9 module - 57.5 mm 6.9 module - 57.5 mm 6.9 UP-L, UP or UP-S On sheet metal and Kalzip roofs by means of fastening on standing seams Insertion system time-saving no-screw module installation easy removal of modules for replacement or maintenance work no clip marks optimum load distribution optionally black profiles for visually attractive systems with black modules horizontal and vertical module installation clips fitting for different module frames fastening with flat head screws or hammerhead bolts sheet metal and Kalzip clips TS edging tool depending on type of roof, for different module frames profile for high static loads for edge-trimming the profiles For the insertion system, please comply with the module manufacturer s instructions.

I. Pitched-Roof: Roof-Top 3. Sheet metal roof 3.1 TRI-STAND 3.1.2 Clip system on sheet metal clips 20 UP-L, UP or UP-S On sheet metal and Kalzip roofs by means of fastening on standing seams Clip system materials-saving manufacturer-conforming mode of installation low system costs per kwp standard on the European market optionally black profiles for visually attractive systems with black modules horizontal and vertical module installation clips fitting for different module frames fastening with flat head screws or hammerhead bolts sheet metal and Kalzip clips depending on type of roof, for different module frames profile for high static loads

I. Pitched-Roof: Roof-Top 3. Sheet metal roof 3.2 TRI-STAND Aero 3.2.1 Mounted on clamps for sheet metal transversely to UP-TS profiles for module widths 790-810 mm and 990-1010 mm shading angle V2A drilling screw 6.3 x 40 calculation as a function of the shading angle (Aero 80) 859 mm, (Aero 100) 1062 mm (Aero 80) 859 mm, (Aero 100) 1062 mm V2A drilling screw 6.3x40 hexagonal screw M10x25 A2 sliding nut M10 UP-L or UP profile hexagonal screw M10x25 A2 UP-L or UP profile sliding nut M10 sheet metal seam clamp sheet metal seam clamp Support on sheet metal roofs with southern orientation by means of standing seam or KalZip clips and SafeClick Module installation cost benefit due to fast installation and low materials expenditure, generally without additional weighting manufacturer-conforming module installation at installation drill holes allows module loads of up to 5,400 N/m 2 suitable for all standard modules of a width of 790 to 810 mm and 990 to 1010 mm Mounting system reduced dynamic and wind pressure load by means of wind baffle fixed 20 angle: Reduction of shading clearances and thus higher performance per m 2 standing seam and KalZip clips UP-L profile TS-F angle wind baffle depending on the type of roof material optimised profile with reinforcement and guide ribs for stable installation in two standard designs

I. Pitched-Roof: Roof-Top 3. Sheet metal roof 3.2 TRI-STAND Aero 3.2.2 Mounted on clamps for sheet metal lengthwise to UP-TS profiles for module widths 790-810 mm and 990-1010 mm shading angle (Aero 80) 859 mm, Aero 100) 1062 mm calculation as a function of the shading angle (Aero 80) 859 mm, Aero 100) 1062 mm hexagonal screw M10x25 A2 hexagonal screw M10x25 A2 hammer head bolt M10x20 A2 sliding nut M10 sheet metal seam clamp sliding nut M10 sheet metal seam clamp Support on sheet metal roofs with seast/west orientation by means of standing seam or KalZip clips and SafeClick Module installation cost benefit due to fast installation and low materials expenditure, generally without additional weighting manufacturer-conforming module installation at installation drill holes allows module loads of up to 5,400 N/m 2 suitable for all standard modules of a width of 790 to 810 mm and 990 to 1010 mm Mounting system reduced dynamic and wind pressure load by means of wind baffle fixed 20 angle: Reduction of shading clearances and thus higher performance per m 2 standing seam and KalZip clips UP-L profile TS-F angle wind baffle depending on the type of roof material optimised profile with reinforcement and guide ribs for stable installation in two standard designs

II. Pitched-Roof Elevation 1. TRI-STAND triangle installation with insertion system 1.1 Fastening with roof hooks module + 115 mm + 690 mm module - 575 mm shading angle for installation on pitched roofs with up to 20 roof pitch Insertion system time-saving no-screw module installation easy removal of modules for replacement or maintenance work no clip marks optimum load distribution horizontal and vertical module installation flexible module inclinations (20 /30, 20 70 ) for optimum yield depending on location excellent inherent stability profile for high static loads, required depending on design TS profile insertion profile standard angle fixed support angle 20 or 30 FlexFix angle freely selectable angle between 20 and 70 SafeClick secure profile connection roof hooks for fastening to the substructure on the roof TS edging tool for edge-trimming the profile For the insertion system, please comply with the module manufacturer s instructions.

II. Pitched-Roof Elevation 1. TRI-STAND triangle installation with insertion system 1.2 Fastening with hanger bolts module + 11.5 mm + 690 mm module - 575 mm shading angle UP-L, UP or UP-S for installation on pitched roofs with up to 20 roof pitch Insertion system time-saving no-screw module installation easy removal of modules for replacement or maintenance work no clip marks optimum load distribution horizontal and vertical module installation flexible module inclinations (20 /30, 20 70 ) for optimum yield depending on location excellent inherent stability profile for high static loads, required depending on design TS profile insertion profile standard angle fixed support angle 20 or 30 FlexFix angle freely selectable angle between 20 and 70 SafeClick secure profile connection hanger bolts for fastening to the substructure on the roof TS edging tool for edge-trimming the profile For the insertion system, please comply with the module manufacturer s instructions.

II. Pitched-Roof Elevation 2. TRI-STAND triangle installation with clip system 2.1 Fastening with roof hooks module shading angle UP-L, UP or UP-S for installation on pitched roofs with up to 20 roof pitch Clip system materials-saving manufacturer-conforming mode of installation low system costs per kwp standard on the European market horizontal and vertical module installation flexible module inclinations (20 /30, 20 70 ) for optimum yield depending on location excellent inherent stability profile for high static loads, required depending on design TS profile insertion profile standard angle fixed support angle 20 or 30 FlexFix angle freely selectable angle between 20 and 70 SafeClick secure profile connection roof hooks for fastening to the substructure on the roof

II. Pitched-Roof Elevation 2. TRI-STAND triangle installation with clip system 2.2 Fastening with hanger bolts module shading angle UP-L, UP or UP-S for installation on pitched roofs with up to 20 roof pitch Clip system materials-saving manufacturer-conforming mode of installation low system costs per kwp standard on the European market horizontal and vertical module installation flexible module inclinations (20 /30, 20 70 ) for optimum yield depending on location excellent inherent stability profile for high static loads, required depending on design TS profile insertion profile standard angle fixed support angle 20 or 30 FlexFix angle freely selectable angle between 20 and 70 SafeClick secure profile connection hanger bolts for fastening to the substructure on the roof For the insertion system, please comply with the module manufacturer s instructions.

III. Pitched-Roof: Roof Integrated 1. TRI-ROOF on wooden purlins (module + 11.5 mm) * number of modules + 69 mm 69 module - 57.5 mm 69 module - 57.5 mm 69 module - 57.5 mm 69 module - 57.5 mm 69100 with roof refurbishment and new roofs in combination with existing roof areas or as roof coverage over the whole area with purlin spaces of up to 2.5 m insertion system: Easy replacement of modules compatible with framed standard modules optionally black profiles for visually attractive systems with black modules Impermeability discharge of rain water for the most part via modules specially developed water-bearing carrier profiles UP-I universal profile TR-H profile basic profile for vertical water drainage profile for horizontal water drainage For the insertion system, please comply with the module manufacturer s instructions.

III. Pitched-Roof: Roof Integrated 2. TRI-ROOF on steel purlins (module + 11.5 mm) * number of modules + 69 mm 69 module - 57.5 mm 69 module - 57.5 mm 69 module - 57.5 mm 69 module - 57.5 mm 69 100 with roof refurbishment and new roofs in combination with existing roof areas or as roof coverage over the whole area with purlin spaces of up to 2.5 m insertion system: Easy replacement of modules compatible with framed standard modules optionally black profiles for visually attractive systems with black modules Impermeability discharge of rain water for the most part via modules specially developed water-bearing carrier profiles UP-I universal profile TR-H profile basic profile for vertical water drainage profile for horizontal water drainage For the insertion system, please comply with the module manufacturer s instructions.

III. Pitched-Roof: Roof Integrated 3. TRI-ROOF on tile battening module - 57.5 mm 69 a b 170 module - 57.5 mm (module + 11.5 mm) * number of modules + 69 mm 69 69 module - 57.5 mm 100 100-235 69 100 with roof refurbishment and new roofs in combination with existing roof areas or as roof coverage over the whole area with purlin spaces of up to 2.5 m insertion system: Easy replacement of modules compatible with framed standard modules with standard tile cover, supply of complete sheet metal flashing which can be adjusted to the module size without special know-how optionally black profiles for visually attractive systems with black modules Impermeability discharge of rain water for the most part via modules specially developed water-bearing carrier profiles UP-I universal profile TR-H profile ridge and lateral flashings accessories for sealing valley basic profile for vertical water drainage profile for horizontal water drainage optional with standard tiles sealing strips, special adhesive, adhesive tape FLEX-DICHT For the insertion system, please comply with the module manufacturer s instructions.

IV. Flat Roof 1. Flat roof with low load capacity 1.1 TRI-STAND Aero for module widths 790-810 mm and 990-1010 mm ballast shading angle ballast calculation as a function of the shading angle (Aero 80) 859 mm, (Aero 100) 1062 mm (Aero 80) 859 mm, (Aero 100) 1062 mm hexagonal screw M10x25 A2 hexagonal screw M10x25 A2 hammer head bolt M10x20 A2 hammer head bolt M10x20 A2 hammer head bolt M10x20 A2 No Regupol protective strips between module rows! Regupol protective strip Regupol protective strip up to max. 5 roof inclination with horizontal module installation with film cover or bitumen gravel-covered roofs or green roof areas Installation fast module installation with few components; yet more time-saving with preassembled supports no penetration of roof membrane possible module load of up to 5,400 N/m 2 manufacturer-conforming module installation at installation drill holes suitable for standard modules of a width of 790 to 820 mm and 990 to 1010 mm Ballast aerodynamically optimized for s with low load capacity flexible weighting on the rear by means of concrete slabs or flagstones reduced dynamic and wind pressure load by means of wind deflector UP-C connector TS-F angle wind deflector Regupol film profile for high static loads, required depending on design if necessary for the connection of continuous rails fixed 20 inclination for optimum shading clearance in two standard designs for optimum roof protection

IV. Flat Roof 1. Flat roof with low load capacity 1.2 TRI-STAND east/west support module clamp angle 10 mounting angle 10 angle 10 hammer-head bolt M10x20 A2 and self-locking nut M10 A2 hammer-head bolt M10x20 A2 and self-locking nut M10 A2 angle 10 support 10 module clamp Ballast for aluminium sheet Ex.: stone dimension 25 x 12,5 x 5, ca. 3,6 kg/stone 3 stones x 3,6 kg/stone = 10,8 kg Gravel roofs and green roof areas Trapezoidal sheet metal and standing seam roofs Installation clip system: Manufacturer-conforming module installation no penetration of roof membrane possible module load of up to 5,400 N/m 2 Ballast aerodynamically optimized for s with low load capacity flexible weighting on the rear by means of concrete slabs or flagstones profile for high static loads, required depending on design support angle 10 and 20 UP-TS profile for installation on trapezoidal sheet metal roof

IV. Flat Roof 2. Flat roof with normal load capacity 2.1 TRI-STAND triangle installation 2.1.1 Insertion system module + 11.5 mm + 690 mm module - 575 mm shading angle UP-L, UP or UP-S Renosol panels 800x600x35 roof areas with gravel, granulate, bitumen or film cover for additional module inclinations on pitched roofs with up to 20 roof pitch gravel-covered roofs or green roof areas Insertion system time-saving no-screw module installation easy removal of modules for replacement or maintenance work no clip marks optimum load distribution horizontal and vertical module installation flexible module inclinations (20 /30, 20 70 ) for optimum yield depending on location excellent inherent stability profile for high static loads, required depending on design TS profile insertion profile standard angle fixed support angle 20 or 30 FlexFix angle freely selectable angle between 20 and 70 SafeClick secure profile connection Renosol plates for fastening to the substructure on the roof TS edging tool for edge-trimming the profiles For the insertion system, please comply with the module manufacturer s instructions.

IV. Flat Roof 2. Flat roof with normal load capacity 2.1 TRI-STAND triangle installation 2.1.2 Clip system module shading angle UP-L, UP or UP-S Renosol panel 800x600x35 roof areas with gravel, granulate, bitumen or film cover for additional module inclinations on pitched roofs with up to 20 roof pitch gravel-covered roofs or green roof areas Clip system materials-saving manufacturer-conforming mode of installation low system costs per kwp standard on the European market horizontal and vertical module installation flexible module inclinations (20 /30, 20 70 ) for optimum yield depending on location excellent inherent stability profile for high static loads, required depending on design TS profile insertion profile standard angle fixed support angle 20 or 30 FlexFix angle freely selectable angle between 20 and 70 SafeClick secure profile connection Renosol plates for fastening to the substructure on the roof

IV. Flat Roof 2. Flat roof with normal load capacity 2.2 TRI-STAND upright installation 2.2.1 Insertion system module + 11.5 mm + 690 mm module -575 mm shading angle Renosol panel 800x600x35 s with inclinations from -5 to +5 roof areas with gravel, granulate, bitumen or film cover for green roofs, uneven roofs and locations with heavy snowfall Insertion system time-saving no-screw module installation easy removal of modules for replacement or maintenance work no clip marks optimum load distribution Installation horizontal and vertical module installation flexible module inclinations (20 /30 ) for optimum yield depending on location large distance of modules to the roof, thus less shading excellent inherent stability TRI-DESIGN software for optimum, standard planning and dimensioning of the system profile for high static loads, required depending on design TS profile insertion profile standard angle fixed support angle 20 or 30 SafeClick secure profile connection Renosol plates for fastening to the substructure on the roof TS edging tool for edge-trimming the profiles For the insertion system, please comply with the module manufacturer s instructions.

IV. Flat Roof 2. Flat roof with normal load capacity 2.2 TRI-STAND upright installation 2.2.2 Clip system shading angle UP-L, UP or UP-S Renosol panel 800x600x35 s with inclinations from -5 to +5 roof areas with gravel, granulate, bitumen or film cover for green roofs, uneven roofs and locations with heavy snowfall Clip system materials-saving manufacturer-conforming mode of installation low system costs per kwp standard on the European market Installation horizontal and vertical module installation flexible module inclinations (20 /30 ) for optimum yield depending on location large distance of modules to the roof, thus less shading excellent inherent stability profile for high static loads, required depending on design TS profile insertion profile standard angle fixed support angle 20 or 30 SafeClick secure profile connection Renosol plates for fastening to the substructure on the roof

UP-L, UP or UP-S (length od module + 20) * number of modules - 20 (en mm) lenght of module length of module height of module field = (length of module insertion + 115 mm) * number of modules + 69 mm module - 57.5 mm module - 57.5 mm module - 57.5 mm UP-L, UP or UP-S V. FACADE 1. TRI-STAND vertical installation on s by means of hanger bolts directly on s by means of dowels or wood screws Module installation Insertion system: optimum load distribution and time-saving no-screw installation Clip system: materials-saving mode of installation and low system costs per kwp Facade Installation low module load (only wind pressure and suction) no plastering of s necessary developing new areas for PV systems UP universal UP-S universal UP-C universal profile UP-TS profile TS edging tool profile profile profile for high static loads secure connection of profiles with insertion systemm for SafeClick installation directly on building exterior for edge-trimming the profiles (insertion system) For the insertion system, please comply with the module manufacturer s instructions.

V. FACADE 2. TRI-STAND inclined installation anchoring forces AH, AV, BH and BV anchoring forces AH, AV, BH and BV vertical row spacing module + 11.5 mm + 690 mm module - 575 mm shading angle UP-L, UP or UP-S module inclincation length of horizontal support UP profile UP-S profile length of an individual wall rail clearance for individual wall rails length of an individual wall rail row spacing shading angle module inclincation UP-L, UP or UP-S UP profile length of horizontal support UP-L, UP or UP-S UP profile UP-S profile length of an individual wall rail length of an individual wall rail clearance for individual wall rails PV systems with canopy roof function Module installation on s by means of hanger bolts directly on s by means of dowels or wood screws Facade installation developing new areas for PV systems flexible angle of inclination (20 70 ) (insertion system) profile for high static loads, required depending on design TS profile insertion profile FlexFix angle freely selectable angle between 20 and 70 SafeClick secure profile connection TS edging tool for edge-trimming the profiles For the insertion system, please comply with the module manufacturer s instructions.