PA39 TYPE PANEL POWER METERS APPLICATION CHOICE OF MEASURING RANGE TECHNICAL DATA. Additional errors

Similar documents
MOVING-COIL METERS MA16, MB16, MA17, MA17P, MA19, MA19P, MA12, MA12P TYPES

B2, B3, B4, B5, B6 Measuring shunts

ANSI Switchboard Meters

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

TECHNICAL DESCRIPTION

ORION PLUS three-phase kVA

Displacement Sensor. Model 8739, 8740, 8741

AC Wattmeters and VArmeters

DIN Panel Meters Long Scale

AC/DC CURRENT TRANSDUCER 600A 10mV/1A, 1mV/1A

Electromagnetic Flow Monitor magphant

Technical Data Sheet Sigma Series DS Meter

POWER FACTOR METERS LF 72 / LF 96 ANALOGUE METERS

SIGMA SERIES DE METER

D509E. Manual Motor - Starters

RUC industrial relays of small dimensions

AC/DC CURRENT TRANSDUCER INSTRUCTION MANUAL

M Series 010.D Data Sheet. Analog Meters with Moving-Coil Movement, 90 Dial PSQ 48 PQ 72 RS PQ 96 RS PQ 144 RS

Operating Instruction for Flowmonitor. Model: DF-WM

Dawson DAN100. Analog Multimeter User s Manual

KINAX SR 709 Transmitter for Position Feedback

MEASURING INSTRUMENTS. Basic Electrical Engineering (REE-101) 1

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

M Series 140.D Data Sheet. Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial RW 96 RP 96

Medium Voltage. KOFD Indoor Type Current Transformers Cast Resin Insulated. Catalogue. 12, 13.8, 17.5, 24 and 36 kv KOFD 1 GB

SOLENOID VALVES AND PNEUMATIC VALVES

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Analog input module. Brief description. Page 1/8. Data Sheet

Datasheet. Pitch Motor PMSM SP190C8

Datasheet. Pitch Motor PMSM SP260B8

Datasheet. Pitch Motor PMSM SP190F8

Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage

ahead of time Voltage Stabilisers

TECHNICAL DESCRIPTION

PowerIT Indoor Voltage Transformer Fuses, WBP. Outdoor Voltage Transformer Fuses, BRT. Catalogue 1YMB en. Industrial IT.

Process controller. for pneumatic and electric actuators. Process controller V. Process controller

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Gas-actuated thermometer with switch contacts Model 73, stainless steel version

Smart Look Series Meter

Powermite 599 Series MZ Series SSB Electronic Valve Actuator 24 Vac Proportional Control

TABLE OF CONTENTS. 8.3 Online Sensor Specifications. Series TS (Models TS1, TSP, TSH, TSL,TSF, TSB1, TSB2) According to Electromatic factory procedure

201A-9 INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 01/2010

Moving Coil Indicators with direct temperature sensor input

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Torque Motors 3 W, 6 W, 10 W, 20 W

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Motor-drive mechanism, type BUL. Technical guide

Level Limit Switch liquiphant FTL 360 / FTL 361

VEO. V2TF01 Art.Nr.: V2TF01P Art.Nr.: TECHNICAL DATA

System 350 P352AB Electronic Pressure Control Series

Differential Pressure Sensors

Panel Meters and Accessories Digital Panel Meter

KINAX SR 709 Transmitter for position feedback

BHARAT ALUMINIUM COMPANY LTD. SPECIFICATIONS FOR SYNCHRONOUS GENERATOR GENERAL Make : Jinan Power Equipment Factory Type : WX2

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)

Series KTU7 UL489 Molded Case Circuit Breakers

KECA 80 C85 Current Sensor Instructions for installation, use and maintenance

Technical information

Differential Pressure Sensors

Paddle-wheel flow controller for On/Off control

Level switches (two-term level controllers) ERH-xx-04,-06,-07,-16,-16.1 Description

MULTICHANNEL ULTRASONIC FLOW METER AFLOWT UF

MEDIUM VOLTAGE PRODUCT. KECA 80 D85 Current Sensor Instructions for installation, use and maintenance

Differential Pressure Sensors

Three-phase isolating transformers for photovoltaic and wind-power systems

Pressure transmitter JUMO dtrans p02

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

PRODUCT/TEST MANUAL 2C58K37 INSTANTANEOUS OVERCURRENT RELAY

MELT PRESSURE TRANSMITTERS K7 SERIES PERFORMANCE LEVEL c

Output signal active note. Measuring range rel. pressure. Electrical Data Power supply DC V, ±10%, 1.1 W

Figure 1: WPR2 Dimensions and Hardware

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

Positive displacement batch controller

CI-TI Contactors and Motor Starters Type CI 6-50

Data Sheet. Data Sheet- Shunts. 50 mv 60 mv 75 mv 100 mv 150 mv. Shunts Class 0.5, 1.0

Electromotoric Actuators

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

POB series Coil Tester & Power Supply Units

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Differential Pressure Gauges Cryo Gauge Model , Cu-alloy Model , Stainless Steel Series

DC POWER SUPPLY ALIMENTATION C.C.

JUMO thermocor. Portable measuring system for AMS2750 and CQI-9. Brief description. Block diagram. Special features. JUMO thermocor.

SAX Electronic Valve Actuator

10V. the rack of the oil pump must be on the

Contactors. CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en. Connect - Contact - Control

PRODUCT / TEST MANUAL 2C58K2 INSTANTANEOUS OVERCURRENT

Pressure transmitter for industrial applications Type MBS 4500

Reverse power relay and protection assemblies

BATCHFLUX 5500 C Technical Datasheet

Safety Standards. Model Number:

economics and performance Spark Holland introduces OPTIMAS The optimum balance of BETTER SAMPLE CARE

MF /MS Series

Position switches FC series

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

7 Lighting Technology

Safety drying ovens. Advantages: Areas of application: FDL series 115

www. ElectricalPartManuals. com INS T R U c.t I 0 N S Westinghouse OPER.ATION MAINTENANCE INSTALLATION SWITCHBOARD INSTRUMENTS SIX-INCH CLASSIFICATION

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

Transcription:

PANEL POWER METERS PA39 TYPE Additional errors acc. EN 60051-1 standard Power consumption: - voltage circuit 3 VA - current circuit 0.25 VA Protection Grade acc. to EN60529 Front protection grade: - IP 50 for PA39 meters - IP 65 for PA39 meters (on request): IP20 terminal protection (with a terminal protection cover) Electromagnetic compatibility: - emission acc. EN 61000-6-4 standard - immunity acc. EN 61000-6-2 standard The meter fulfils CE mark requirements. Safety requirements acc. EN 61010-1: - installation category III - level of pollution 2 - working voltage in relation to the earth 600 V a.c. Weight 400 g APPLICATION The PA39 power meter is a mowing-coil meter with a built-in measuring transducer. It is destined to measure active or reactive power in a.c. power networks. The measured power is indicated by a magnetoelectric (moving-coil) measuring system. These meters are delivered in following versions: - for measuring the active power in single-phase systems, - for measuring the active or reactive power in three-phase three-wire or four-wire symmetrically or asymmetrically loaded systems, - with the zero graduation on the left side of the scale for measuring the unidirectional power flow, - with the zero graduation in the middle of the scale for measuring the bidirectional power flow. TECHNICAL DATA Measuring ranges acc. the series 1, 1.2, 1.5, 2, 2.5, 3, 4, 5, 6, 7.5, 8, or the decimal multiplication of one of these numbers Input voltage 100 3 (x/100/ 3),100 (x/100), 133, 230, 280, 400, 500, 690 V Input current 1 A (x/1 A), 5 A (x/5 A) Active power factor cos -0.5 cap...1...0.5 ind Reactive power factor sin -0.5 cap...1...0.5 ind Accuracy class 1.5 Rated operating conditions: - ambient temperature 5...23...40 C 5...35...55 C (on request, tropical execution) - relative humidity 25...85% - frequency of the input quantities acc. order (table 1) - working position acc. order 5 (table 2) - external magnetic field 400 A/m ACCESSORIES We deliver with the meter: - screw holders (IP50 option)... 2 pcs - screw holders (IP65 option)... 4 pcs - terminal protection cover... 1 pc - user s manual... 1 pc - guarantee certificate... 1 pc CHOICE OF MEASURING RANGE 1. Calculate the power from the formulas: P = U n x I n for single-phase networks P = 3 x U n x I n for three-phase networks where: U n - network rated voltage: for three-phase networks - phase-to-phase voltage, when connected through transformers-primary rated voltage. I n - rated current: 5 A or 1 A, when connected through transformers-primary rated voltage. 2. Round the calculated power value to the nearest value from the given sequence of numbers for the measuring range. 3. Example of measuring range choice. Three-phase network; rated values of transformers: 15 000/100 V and 400/5 A P = 3 x 15 000 V x 400 A = 10,39 MW (Mvar) Selected measuring range: 10 MW (Mvar)

EXTERNAL DIMENSIONS OF PA39 METER FOR IP 50 PROTECTION GRADE Fig.1. PA39 meter outline drawing. EXTERNAL DIMENSIONS OF PA39 METER FOR IP 65 PROTECTION GRADE METER SEAL GLASS fixation on the panel One should prepare in the panel a hole at dimensions: 92 +0.8 x 92 +0.8 mm. The thickness of the material of which the panel is made, cannot exceed 15 mm. The meter is fixed in the panel by two screw holders situated on arbitrary opposite corners of the case. cut - out Fig.2. Way of the meter fixation on the panel.

Dial Exchange Dials with graduated scales can be interchanged in all PA39 power meters. This is especially convenient for meters destined to co-operate with measuring transformers. In order to exchange the dial, one can take off the plastic cover (1) placed on the upper part of the case and draw out the dial (2) with a suitable tool Introduced in the dial perforation. When replacing the new dial, carefully close the slot of the case with the plastic cover (see fig. 1). NOTE: When changing the standard rated ranges of PA39 power meters and choosing Un or In quantities inconsistently with values included in the table 3 (measuring ranges), one must recalibrate these power meters acc. calibration instructions given by the manufacturer in the Calibration Service Manual (if ordered). 1. Plastic cover 2. Protractile dial connection diagrams of external circuits Measurement of active power in a single-phase network. Measurement of active power in a three-phase four-wire Measurement of active power in a three-phase three-wire Measurement of active power in a three-phase four-wire asymmetrically loaded network. Measurement of active power in a three-phase three-wire a Measurement of reactive power in a three-phase three-wire

Measurement of reactive power in a three-phase threewire a ORDERING PROCEDURE Table 1 Input voltage Codes frequency fn (Hz) 50 0 60 1 400 2 Measurement of reactive power in a three-phase four-wire Table 2 Code Position O c3 A c1 B c2, = 15 C c2, = 30 D c2, = 45 E c2, = 60 F c2, = 75 H c4, = 105 I c4, = 120 Measurement of reactive power in a three-phase four-wire a Fig.3. Codes and markings concerning the working position.

measuring ranges Table 3

Ordering codes Table 4 PANEL POWER METER - PA39 X X X XX X X XX X Kind of measured power and measuring system: Measurement of active power in a single-phase network...a Measurement of active power in a 3-phase 3-wire...B Measurement of active power in a 3-phase 3-wire a...c Measurement of active power in a 3-phase 4-wire...D Measurement of active power in a 3-phase 4-wire a...e Measurement of reactive power in a 3-phase 3-wire... F Measurement of reactive power in a 3-phase 3-wire a...g Measurement of reactive power in a 3-phase 4-wire...H Measurement of reactive power in a 3-phase 4-wire a...k Input voltage write in the Un range code from the table 3...X Frequency of the input voltage write in the frequency code from the table 1... X Input current write in the In range code from the table 3... XX Flow direction of the power - unidirectional, zero on the left side of the scale... 0 - bidirectional, zero in the middle of the scale... 1 Working position write in the working position from the table 2...X Versions: catalogue...00 custom-made 1)...XX Acceptance tests: without additional requirements... 8 with a quality inspection certificate... 7 other requirements 2)... X 1) The ordering code is given by the manufacturer after agreement. 2) The number code is given acc. customer, s agreement. ORDERING WAY In any order one must specify the name and the ordering code of the power meter using the tables: 1, 2, 3, and 4. Order example: PA39 - H - F - O - L5-0 - O - 00-8, means: H - Reactive PA39 power meter adapted to a three-phase four-wire F - Network rated voltage: 3000 V (from table 3). O - Frequency of the input voltage: 50 Hz (from table 1). L5 - Network rated current: 300 A (from table 3). 0 - Unidirectional power flow. O - Working position: C3, vertical (from table 2). 00 - Catalogue version. 8 - without additional requirements concerning acceptance tests. This power meter is destined to co-operate with 300 A/5 A transformers and a 3000 V/100/ 3 V voltage transformers. Note: concerning casing protection grade IP. When ordering, please precise the required grade option: IP50 or IP65 PA39-19