Similar documents
AIR ZONE INTERNATIONAL MIXED-FLOW AIR COLUMN UNIT

VAHU Vertical Air Handling Unit

Complete HVAC Capability

MAH. Modular Air Handling Unit

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

BAC, BAF, BAH Central Station Air Handlers

Centrifugal Inline Fans

Product Data. Features/Benefits. 39NX Central Station Air-Handling Units. Nominal 2,000 to 55,000 Cfm

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive

FFW/FSW/FHW SERIES FLOOR EXPOSED VERTICAL FAN COIL UNITS

Chilled Water FCU. Horizontal Fan Coil 50hz CFM. A Series.

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

A Division of Nailor International Inc. ECONOMY AIR HANDLERS

HIGH VELOCITY FUME EXHAUST FANS

R-22, 13 SEER 60 Hertz

Energy Recovery Laboratory Exhaust

Midea Air Handling Unit

Tube Axial Inline Fans

RERV & RERVX RERVLP. Rotary Energy Recovery Ventilators. Low Profile Indoor Rotary Energy Recovery Ventilators

Tubular Centrifugal Fans

DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE

D M S 760 C01 A A 1 1

UNIVERSITY OF NORTH FLORIDA Arena HVAC Replacement SECTION MODULAR INDOOR CENTRAL-STATION AIR-HANDLING UNITS

CURBPAK AIR HANDLING UNITS ENGINEERING GUIDE

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101)

IAQ. ROUND DUCT RETROFIT Model ARR

Installation, Start-Up and Service Instructions

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice.

McQuay. Central Station Air Handlers Low Pressure. LHD, LYF, LSL, LML, LWL Vintage C. LML, LSB Vintage E. Last Manufactured: 1999

TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz


Utility Sets Standard Design Features Standard design features common to all Class I and Class II fans

42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application

Inline Fans [ 14 ] * UL is optional and must be specified.

Energy Recovery Laboratory Exhaust

Centrifugal Upblast Power Roof Ventilators

1. Air Handler Features Page Physical data Page Available kits Page Model nomenclature Page 5

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV

Horizontal and Vertical BELT DRIVE AIR HANDLING UNITS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

ZEPHYR CABINET. Single & Twin Unit Cabinet Fans. Moving Your Way BULLETIN ZC15 TABLE OF CONTENTS

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

42CHS-W Series. Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type. Nominal: 400-2,000 CFM. World's No.1 Air Conditioning Expert QMS 001

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

Fixed Pitch Vane Axial Fan

Central Station Air-Handling Units

Consider The Possibilities...

CENTAXIAL TUBULAR CENTRIFUGAL FANS. BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) Model CBD Belt Driven

MQL TABLE OF CONTENTS

Twin City Fan & Blower

TECHNICAL GUIDE FLEXIBLE LIGHT COMMERCIAL UNIT CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS

INDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS

BVX SERIES VERTICAL DIRECT EXPANSION BLOWER COIL UNITS

Godwin Sub-Prime. Pumps. A complete range of electric submersible pumps for construction, mining and industrial applications

Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV

Installation, Start-Up and Service Instructions

SECTION AXIAL HVAC FANS

Product Data. 39T Central Station Air-Handling Units. Features/Benefits. Nominal 3,500 to 46,000 Cfm

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option

LOW PRESSURE MIXED FLOW FANS

AIR HANDLING UNITS. Customisable modular air handling unit, designed and built to suit your project requirements

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

ACPSE-P Series 50Hz 410A. Rooftop Units Cooling Capacity : 26 to 1388 MBH (8 to 407 kw) Heating Capacity : 28 to 1298 MBH (8 to 380 kw)

Tube Axial Fan Page Specifications & Dimension Data Performance Data

SDL Single-Duct, Low-Height, VAV Terminals

Air-Cooled Fluid Cooler

Filtered Kitchen Supply Packaged Ventilator

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404)

Product Data. 35J Single-Duct Retrofit Terminal Units for Variable Air Volume Systems. 40 to 3700 cfm

TSS Single-Duct VAV Terminals

Laboratory Exhaust Systems

Laboratory Exhaust Systems

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

BLACK KNIGHT HPI REPORT

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.

Product Data. Features/Benefits. 45J,M,K,N,Q,R Standard, Quiet, and Low Profile Fan Powered Variable Air Volume Terminals

Roof Upblast and Sidewall Exhaust

forward curved inline duct blowers

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

belt drive utility sets vent-pak series models vp-bi & fc january 2007 vp 1.07

TGIF-3. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

SOLUTION AIR HANDLING UNIT PERFORMANCE SPECIFICATION

42CLS-W Series Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION FEATURES MODELS: AHR18 THRU 60* WARRANTY

Multi-Path RTU-TYPE 9 (RTU-1) CES-MPU-025-RE-VAV9

Product Data. Features/Benefits. 45J,M,K,N,Q,R Standard, Quiet, and Low Profile Fan Powered Variable Air Volume Terminals.

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

Industrial Mini Vent Sets

PennBarry Fan Guide Specification. Laboratory Exhaust System: Model vplume

WE CARRY THE FUTURE SM

IAQ. Model AVC. SINGLE DUCT VAV Model AVC

SINGLE PACKAGE HEAT PUMPS

IQAir Perfect 16 ID-Series MERV16 Micro-Particle Filtration System. Perfect 16. Installation Manual

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan

DESIGN GUIDELINES FANS PAGE 1 of 7

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK

Transcription:

STANDARD DESIGN FEATURES DRAIN PAN DETAILS COIL SUPPORTS 2"-3# INSULATION OPTIONAL SS LINER DRAIN PAN CONSTRUCTION GALVANIZED DOUBLE SKIN - IAQ DRAIN PAN STANDARD OPTIONAL 304 & 316 STAINLESS STEEL DRAIN PANS COIL IS ABOVE PAN WITH SUPPORTS 24" ON CENTER 2"-3# INSULATION ENCAPSULATED & SURROUNDING PAN RUGGED STEEL CHANNEL BASE WITH SOLID BOTTOM WELDED UNITIZED ASSEMBLY-FACTORY LEAK TESTED 1 ¼" MPT DRAIN CONNECTION AT THE LOWEST POINT DRAIN DRY DESIGN IN ACCORDANCE WITH ARI & ASHRAE DOUBLE SLOPE DESIGN IN ACCORDANCE WITH IAQ STANDARDS OPTIONAL SS CONNECTION COIL IS ABOVE PAN FOR 12 GA. COIL SUPPORTS CLEANING 30" (MAX) PLAN VIEW OF STANDARD DRAIN PAN OPTIONAL PLENUM FANS ARE SIMILAR OPTIONAL OSHA BELT GUARD AMCA RATED DIDW FANS CAST IRON PULLEYS & MATCHING BELTS UL LISTED & NEMA RATED MOTORS NEMA ADJUSTABLE MOTOR BASE WELDED STRUCTURAL STEEL BASE FAN ASSEMBLY DETAILS INDUSTRIAL TYPE FLEX CONNECTION OPEN SPRING ISOLATORS SEISMIC TYPE OPTIONAL

SELECTION PROCEDURE Step 1: Determine unit type and arrangement from the Basic Unit Arrangement diagrams. Step 2: Determine unit size based on CFM, coil face area and the desired face velocity. Normally a face velocity between 500 and 550 FPM is acceptable for most applications. A careful review of the purchasers specifications should be made to determine if a maximum face velocity is required. Step 3: Select cooling and heating coils that meet the required face velocity & provide performance as required. Utilize the computerized coil selection program to select the required coil rows and fin type. Step 4: Review the basic unit and accessories to determine if the selected model will fit within the available space. See the dimensional drawings contained in this catalog when selecting each section. Step 5: Select a fan type suitable for the application and utilize the computerized fan selection program. Step 6: A complete selection procedure may require factory assistance. If you need assistance with a selection or if training is required contact the factory by fax or E-mail. PHYSICAL DATA UNIT SIZE 04 07 10 13 15 17 21 26 30 LARGE COIL 3.89 7.64 10.50 13.32 15.31 17.01 21.39 25.94 30.21 FH x FW 20 x 28 25 x 44 27.5 x 55 32.5 x 59 35 x 63 35 x 70 40 x 77 45 x 83 50 x 87 COOLING MED. COIL 3.40 6.88 9.55 11.27 13.13 14.58 18.72 23.06 27.19 COIL FH x FW 17.5 x 28 22.5 x 44 25 x 55 27.5 x 59 30 x 63 30 x 70 35 x 77 40 x 83 45 x 87 SMALL COIL 2.92 5.35 7.64 9.22 10.94 12.15 16.04 18.73 22.66 FH x FW 15 x 28 17.5 x 44 20 x 55 22.5 x 59 25 x 63 25 x 70 30 x 77 32.5 x 83 37.5 x 87 LARGE COIL 3.89 7.64 10.50 13.32 15.31 17.01 21.39 25.94 30.21 FH x FW 20 x 28 25 x 44 27.5 x 55 32.5 x 59 35 x 63 35 x 70 40 x 77 45 x 83 50 x 87 MED. COIL 3.40 6.88 9.55 11.27 13.13 14.58 18.72 23.06 27.19 HEATING FH x FW 17.5 x 28 22.5 x 44 25 x 55 27.5 x 59 30 x 63 30 x 70 35 x 77 40 x 83 45 x 87 COIL SMALL COIL 2.92 5.35 7.64 9.22 10.94 12.15 16.04 20.17 22.66 FH x FW 15 x 28 17.5 x 44 20 x 55 22.5 x 59 25 x 63 25 x 70 30 x 77 32.5 x 83 37.5 x 87 MULTI-ZONE 1.94 3.82 5.73 7.17 7.66 8.51 10.69 12.97 15.10 FH x FW 10 x 28 12.5 x 44 15 x 55 17.5 x 59 17.5 x 63 17.5 x 70 20 x 77 22.5 x 83 25 x 87 350 FPM 1,362 2,674 3,675 4,662 5,359 5,954 7,487 9,079 10,574 400 FPM 1,556 3,056 4,200 5,328 6,124 6,804 8,556 10,376 12,084 CFM(D) 450 FPM 1,751 3,438 4,725 5,994 6,890 7,655 9,626 11,673 13,595 LARGE COIL 500 FPM 1,945 3,820 5,250 6,660 7,655 8,505 10,695 12,970 15,105 550 FPM 2,140 4,202 5,775 7,326 8,421 9,356 11,765 14,267 16,616 600 FPM 2,334 4,584 6,300 7,992 9,186 10,206 12,834 15,564 18,126 UNIT SIZE 33 36 40 51 59 69 77 85 103 LARGE COIL 32.64 35.90 40.10 51.04 58.33 69.27 76.56 85.31 103.02 FH x FW 50 x 94 55 x 94 55 x 105 70* x 105 80* x 105 95* x 105 105* x 105 105* x 117 115* x 129 COOLING MED. COIL 29.38 32.64 36.46 43.75 54.69 61.98 65.63 70.83 94.06 COIL FH x FW 45 x 94 50 x 94 50 x 105 60* x 105 75* x 105 85* x 105 90* x 105 90* x 117 105* x 129 SMALL COIL 24.48 26.11 29.16 38.28 43.75 51.04 58.33 65.00 76.15 FH x FW 37.5 x 94 40 x 94 40 x 105 52.5 x 105 60* x 105 70* x 105 80* x 105 80* x 117 85* x 129 LARGE COIL 32.64 35.90 40.10 51.04 54.69 65.63 72.92 81.25 89.58 FH x FW 50 x 94 55 x 94 55 x 105 70 x 105 75 x 105 90* x 105 100* x 105 100* x 117 100* x 129 MED. COIL 29.38 32.64 36.46 43.75 54.69 54.69 61.98 70.83 80.63 HEATING FH x FW 45 x 94 50 x 94 50 x 105 60 x 105 75 x 105 75 x 105 85* x 105 90* x 117 90* x 129 COIL SMALL COIL 24.48 26.11 29.17 38.28 43.75 51.04 54.69 60.94 71.67 FH x FW 37.5 x 94 40 x 94 40 x 105 52.5 x 105 60 x 105 70 x 105 75 x 105 75 x 117 80* x 129 MULT-IZONE 16.32 17.95 20.05 25.52 29.17 34.64 40.1 44.69 51.51 FH x FW 25 x 94 27.5 x 94 27.5 x 105 35 x 105 40 x 105 47.5 x 105 55 x 105 55 x 117 57.5 x 129 350 FPM 11,424 12,565 14,035 17,864 20,416 24,245 26,796 29,859 36,057 400 FPM 13,056 14,360 16,040 20,416 23,332 27,708 30,624 34,124 41,208 CFM(D) 450 FPM 14,688 16,155 18,045 22,968 26,249 31,172 34,452 38,390 46,359 LARGE COIL 500 FPM 16,320 17,950 20,050 25,520 29,165 34,635 38,280 42,655 51,510 550 FPM 17,952 19,745 22,055 28,072 32,082 38,099 42,108 46,921 56,661 600 FPM 19,584 21,540 24,060 30,624 34,998 41,562 45,936 51,186 61,812 NOTES: A. Coils with an * are divided into two or more coils that are stacked or staggered. Cooling coils also have an intermediate drain pan. B. The small coil is used for internal face & by-pass. Heating coils may be full height to allow heating to by-pass over cooling. C. The Multi-Zone coil is the standard heating coil utilized in Multi-Zone, Dual Dal Duct units and Triple Deck Units. D. The nominal CFM shown above is based on the large cooling coil E. All coil FH dimensions are based on coils with 1/2" tubes; if coils with 5/8" tubes are used coil height must be based on 1.5" tube centers.

QUALITY AIR HANDLING EQUIPMENT Compact Air Units Series: HDT / VDT-FC Available 600 thru 8,800 CFM Horizontal or Vertical Enclosed Cabinet Type Belt or Direct Drive Single or Double Wall Multi-Zone Air Units Series: HMZ/VMZ Available 600 through 60,000 CFM Modular Design up to 12.0" TSP FC, BI, AF or Plenum Fans Indoor, Outdoor or Roof Top Design Single or Double Wall Partial List of Installations Custom Air Units Series: VDT-CU Available 5,000 through 20,000 CFM Modular Design Under Floor Units Ultra Quiet Direct-Drive Plenum Fans DDC Controls and VF Drive Double Wall Design-Laboratory Tested Commercial Roof-Top Units Series: HDT-RT Available 600 through 60,000 CFM Modular Design up to 6.0" TSP FC, BI, AF, Plenum or Vane Axial Fans IRoof Ready Roof-Top Units Single or Double Wall ABN-AMBRO 30-Story Tower Ft. Bend 2-Schools Randolph AFB Chicago, IL Houston, Texas San Antonio, Texas Atlas Refinery General Electric Corp. River Oaks Baptist Sch. Lake Charles, LA Mt. Vernon, IN Houston, Texas ARCO Refinery Huntsman Industries SVGL Lithography Long Beach, CA Philadelphia, PA Ridgefield, CT Atlantic Surgery Center Legacy Bank Sunny Farmingdale Atlantic City, NJ Dallas, Texas Farmingdale, NY Bernhard College Middleton Tobacco Co. Thomas Jefferson Univ. New York, NY Philadelphia, PA Philadelphia, PA Bio-Immune Laboratory Mitertek Headquarters San Antonio ISD Long Island, New York Chicago, IL San Antonio, Texas Bristol Meyers Squibb Merck & Co. Laboratories Sam Houston Univ. Philadelphia, PA Philadelphia, PA Huntsville, Texas Computer Associates Hdq. Methodist Hospital San Jacinto College Dallas, Texas Houston, Texas Houston, Texas Duke University Mobil Refinery Top Flight Corp. Durham, NC Port Naches, Texas Philadelphia, PA E.I Du Ponte Moses Industries University of Texas Orange, Texas Fairfield, NJ Galveston, Texas Empire State Building Mulholand School TSU University New York, NY Los Angeles, CA Dallas, Texas Enron 33-Story Office Tower Naval Foundry U.S. Navy Houston, Texas Philadelphia, PA Virginia Beach, VA FAA LAB & Tech. Center N. E. School District Univ. of Pennsylvania Atlantic City, NJ El Paso, Texas Philadelphia, PA Firestone Rubber Pennzoil Office Towers USA Today Hdq. Orange, Texas Houston, Texas Mc Lean, VA Fluor-5-Office Buildings Phibro, USA VA Hospital Houston, Texas Deer Park, Texas Philadelphia, PA First India Place QVC Sound Studio US Navy New Delhi, India Philadelphia, PA Okinawa, Japan 5220 TED STREET HOUSTON, TEXAS 77040 PHONE (713) 460-4040 FAX (713) 460-4050