Riva Plus HEAT ONLY & COMBI BOILER. Please Read This Guide Carefully and Save for Future Reference

Similar documents
Saf-T Vent EZ Seal. Technical and Dimensional Data. Single Wall AL 29-4C Stainless Steel Special Gas Vent

ELECTRIC SHOCK HAZARD/FIRE AND/OR EXPLOSION HAZARD. ELECTRIC SHOCK HAZARD/FIRE AND/OR EXPLOSION HAZARD.

Direct or Non-Direct Venting

Vertical Balanced Flue Kit All Internal Grant Boilers

Saf-T Vent EZ Seal. Technical and Dimensional Data. Single Wall AL 29-4C Stainless Steel Special Gas Vent

INSTALLATION INSTRUCTIONS FOR SOLID VENT KIT PART NUMBER

Saf-T Vent EZ Seal. Technical and Dimensional Data. Single Wall AL 29-4C Stainless Steel Special Gas Vent

Saf-T Vent EZ Seal. Technical and Dimensional Data. Single Wall AL 29-4C Stainless Steel Special Gas Vent

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

Flue installation instructions. Air flue duct for use with ecomax and ecotec boilers. For the installer

DuraChimney II. Air-cooled chimney system for masonry fireplaces. UL 103.

SELKIRK CORP INSTALLATION INSTRUCTION SUPPLEMENT MODEL G - CHIMNEY LINER

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS CWUH9 WALL MOUNT HOOD

Viking Installation Guide

INSTALLATION INSTRUCTIONS JCH/C2 DESIGNER SERIES WALL MOUNT HOOD

venting systems for high efficiency appliances series

DV Power Vent System Model 7THPDVS

INSTALLATION INSTRUCTIONS WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS JDH/C2 DESIGNER SERIES WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS CWSH3 WALL MOUNT HOOD

FLUE PIPE ACCESSORIES FOR STANDARD AND CONDENSING GAS BOILERS

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

Model DW Series Positive Pressure Guidelines for Engine Exhaust Systems

INSTALLATION INSTRUCTIONS ZTH WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

INSTALLATION INSTRUCTIONS K SERIES LINER INSERT

INSTALLATION INSTRUCTIONS ISLAND LINER INSERT

Model DW Series Positive Pressure Guidelines for Engine Exhaust Systems

Installation, Operation and Maintenance Manual

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

GE Monogram. Installation. Instructions. Professional Vent Hoods. 48" Models ZV881WSS, ZV891YSS ZV880WSS, ZV890YSS. 36" Models ZV671WSS, ZV681YSS

RECEIVING AND INSPECTION EXAMINE ALL COMPONENTS FOR POSSIBLE SHIPPING DAMAGE PRIOR TO INSTALLATION.

OPTIONAL VERTICAL OR HORIZONTAL POWER VENT KIT

NOTICE: The information contained on the following page(s) was produced prior to May 1, On that date Reznor became part of Nortek, Inc.

INSTALLATION INSTRUCTIONS K-SERIES UNDER CABINET HOOD

GRAVITY INTAKE AND EXHAUST ROOF VENTILATORS

Power Direct Vent PDV T Model

LE MODELS: SHIPPING, RIGGING, LIFTING, ASSEMBLY MANUAL

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTRUCTIONS INSTALLATION OF NEMA-3R KIT FOR 43, 44 & 52 FRAME AF-6 DRIVES INTO WELDED ENCLOSURES

RECTANGULAR, 2-HOUR FIRE RATED, ZERO-CLEARANCE GREASE DUCT CO.

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

Installation, Operation and Maintenance Manual

EXTERIOR BASE MOUNT INSTALLATION (FIG. 2)

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

Gas Venting Systems residential industrial commercial

Table of Contents WARRANTY...3 APPLICATION...4 MECHANICAL...5 Joint Sealant...5 Grease Duct Standard Connection...6 Collar and Adjustable Duct

Defender Series. Overfill Prevention Valve. Automatic Shutoff for USTs. Installation, Operation and Maintenance Series

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD

Replacement Parts List

Direct Vent Top Exit Vertical Flue Kit

15B SERIES II. Cast Iron Gas Fired Boilers For Forced Hot Water REPAIR AND REPLACEMENT PARTS

KG7T (E and N Series)

Installation Instructions

Orifice Flange Union Assembly and Orifice Run Installation and Operation Manual

FG7T (E and N Series)

OV-1 STANDING SEAM OVERVIEW. Temple Architectural Products 638 Moore Rd Avon Lake, OH 44012

RECEIVING AND INSPECTION

PRE-INSTALLATION GUIDE

Installation Manual. English. French

P/N Deluxe Model 1200T WITH THERMOSTAT P/N Standard Model 3550 WITHOUT THERMOSTAT

LTV VALVE APPLICATION INSTRUCTIONS FOR

CONTENTS. Ordering Information... Page 3. Cardrona, Monaco, Geneva, Vienna... Page 4 Offset & Extension Kits For Freestanding Fires...

BMK-12. Dual-Gard By-Pass Filter Mounting Kit Installation and Servicing Instructions

Technical and Dimensional Data. Double Wall One Inch Air Space AL 29-4C Stainless Steel Special Gas Vent

Date: Project #: Engineer: Prepared By: Bid Date:

A1100 GUARDIAN OVERFILL PREVENTION SYSTEM

Model AM2 M40 Panel Installation, Operation, and Maintenance Manual

HIGH CAPACITY POWER VENT KIT

TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat)

Automatic Roof Door Vents

OPTIONAL HORIZONTAL VARIABLE DEPTH POWER VENT KIT

Model RIS ALL FUEL, INSULATED CHIMNEY SYSTEM 10" - 24"

SINGLE WALL AL 29-4C SPECIAL GAS VENT

TURNING AIR INTO SOLUTIONS. LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. LHD/LHB (Exhaust/Supply) LHDF/LHBF (Filtered Supply)

Opening hours Monday - Friday, 8.00am pm Weekends and Bank Holidays, 8.30am pm We are closed on Christmas Day and New Year s Day.

PRE-INSTALLATION VENTING AND COMBUSTION AIR DESIGN GUIDE

REPLACEMENT PARTS MANUAL HEAT KING HK300. Mobile Glycol Heating System

INSTALLATION, OPERATION, SERVICE & REPAIR PARTS MANUAL FOR

XID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE

KG7T (C and L Series)

KG7T (C and L Series)

Principals of Operation... 1 Rotary Vane Priming Pump VPE and VPES... 2 Rotary Vane Priming Pump VPO and VPOS Priming Valve...

Public Health Services San Joaquin Co.

TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

GUH 95 Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Filter Lock ... SERIES 21FL/26FL/38FL/42FL CONSTRUCTION FEATURES PRODUCT DATA CLEAN-LINE TM 21FL/26FL/38FL/42FL PD-CLFL-03A JANUARY 2003

FG7S (C and L Series)

CSA CERTIFIED Conforms to UL 507

Technical and Dimensional Data. Double Wall One Inch Air Space 316L Stainless Steel Special Gas Vent

OIL FIRED LOWBOY FURNACE SPECIFICATIONS

Installation, Start-Up and Service Instructions

REPLACEMENT PARTS MANUAL HEAT KING HK150. Mobile Glycol Heating System

2520- EC Motor Speed Controller

Transcription:

Condensing Vent Component & Installation Guide Riva Plus HEAT ONLY & COMBI BOILER Please Read This Guide Carefully and Save for Future Reference - This guide is intended to provide detailed information regarding venting components and installation. - This guide must be used in conjunction with the boiler installation manual. Prepared by: QHT, Inc. Portsmouth, NH 603-334-6400 phone www.qhtinc.com Rev: 05.05.09

2

Table of Contents: Restrictor Sizing Chart.... 4 External Vent Warnings. 4 External Vent Clearances. 5 Concentric Riser Kit - RI PLUS VC RIS 10999.0389. 6 Concentric Riser Kit Installation Instructions. 7-9 Standard Concentric Kit - RI PLUS VC 10999.0387. 10 Standard Concentric Kit Installation Instructions.. 11-12 Concentric Vent Accessories... 13 RI PLUS VC EXT - 10999.0388 RI PLUS VC 90-10999.0390 RI PLUS VC 45-10999.0391 Separate Kit - RI PLUS VS 10999.0393..... 14 Separate Kit Installation Instructions.. 15-16 Separate Vent Accessories.. 17 RI PLUS VS EXT 10999.0394 RI PLUS VS 90F 10999.0395 RI PLUS VS 45 10999.0396 Vertical Roof Vent Kit - RI PLUS RV 10999.0392 18 Vertical Roof Vent Kit Installation Instructions 18-20 Vertical Roof Vent Accessories. 21 RI PLUS RV EXT 10999.0407 RI PLUS RV 90 10999.0408 RI PLUS RV 45 10999.0409 Vertical Roof Vent Accessories Cont... 22 RI PLUS RV FF 10999.280 RI PLUS RV PF 10999.252 3

Restrictor Sizing Chart Vent Type Length (ft) Restrictor Size Concentric Separate 1.65 to 3 3.3 to 39.4 (tot. in + out) 82 45 3.3 to 8.8 39.4 to 99 (tot. in + out) NONE None Vertical 3.3 to 27.8 None Exterior Vent Warnings CAUTION EXTERNAL VENT SURFACES ARE HOT. IT IS THE RESPONSIBILITY OF THE HOMEOWNER TO KEEP THE VENT TERMINAL CLEAR OF SNOW AND ICE. NOTE: USE ONLY LISTED COMPONENTS SUPPLIED WITH THE BOILER. SURFACE DISCOLORATION OF THE BUILDING MAY OCCUR DUE TO IMPROPER INSTALLATION. QHT, INC. WILL NOT ACCEPT RESPONSIBILITY OF LIABILITY FOR SUCH DISCOLORATION. 4

Exterior Vent Clearances Mechanical draft vent termination Less than 10 ft 12 in. minimum 12 in. minimum 12 in. minimum 3 ft minimum The Exhaust Hood should be installed on the leeward side of the house and conform to the following guidelines: 1. The vent hood shall not be less than 3 feet above any forced air inlet to the house. 2. The vent hood shall not be less than 1 foot below, 1 foot horizontally, or 1 foot above any door, window or gravity inlet into any building. 3. The vent hood shall not be less than 2 feet from an adjacent building. 4. The vent hood shall be not less than 7 feet above grade when located adjacent to a public walkway. 5. The vent hood shall be located so that flue gasses are not directed to jeopardize people, overheat combustible structures, materials or enter buildings. Do not install hood below a deck. 6. Minimum of 4 horizontal clearance from electric meters, gas meters, regulators and relief equipment. 7. Care should be taken to ensure the rubber gaskets in ALL vent joints are properly assembled to prevent leakage of products of combustion in the building. 8. Avoid installing exhaust the hood on the North, West, or the side of the house receiving the prevailing winds. 5

Concentric Riser Vent Kit - RI PLUS VC RIS - 10999.0389 A. FRESH AIR GASKET 4IN (3) B. EXHAUST GASKET 2.5IN (3) C. RISE EXHAUST PIPE (18 ) D. RISE INTAKE PIPE (20 ) E. BOILER GASKET (1) F. FLANGE SCREWS (4) G. FLANGE (1) H. 90 DEG ELBOW (1) I. CENTERING SPRING (1) J. INTAKE TERMINATION(1) K. FLUE EXHAUST PIPE WITH TERMINATION (38 ) L. WALL GASKET (1) M. WALL GASKET (1) Notes: Length 1 to 8.8 equivalent length 90 Elbow = 3.3 equivalent length 45 Elbow = 1.6 equivalent length 6

Concentric Riser Vent Kit Installation Drill the wall in the chosen position. Useful measurements concerning the position of the pipes and the limit lengths are enclosed in the mounting bracket instructions and in the documents enclosed with the boiler. Figure 1 If it is necessary to cut the pipes C and D, insure that the pipes are cut at the opposite end of the seal hollows Figure 3 C The maximum measurements you can obtain with this kit are shown in the illustration. More information can be obtained from the instructions of the other kits used. 6 29 36 4.5 10 2 2.5 8 5 Figure 4 7

Concentric Riser Vent Kit Installation Cont. Insert the gaskets A, B in the hollows of the elbow H. Insert the gasket A in the hollow of the air intake pipe D. Insert the gasket B in the hollow of flue exhaust pipe C. Insert the gaskets A, B in the hollow of the flange G Ensure that the seals are inserted in the correct orientation as shown in the enlarged detail views. Figure 5 Insert the pipe C into the pipe D completely. Insert the centering spring I. I Figure 6 Fit the gasket E to the boiler. Fix the flange G on the boiler using the screws F. Fit the pipes C & D onto the flange G. Be careful not to damage the gaskets during fitting. Install the elbow H. Figure 7 8

Concentric Riser Vent Kit Installation Cont. Insert the pipe J and the pipe K through the hole in the wall with the terminal protruding out not less than the distance indicated. 6 Figure 8 Insert the wall gaskets L and M on the pipe J. The plastic wall gasket L must be fit inside, the rubber wall gasket M must be fit outside the building. Figure 9 Fix the exhaust pipe K and the air intake pipe J onto the elbow H. Figure 10 9

Standard Concentric Vent Kit - RI PLUS VC - 10999.0387 A. INTAKE TERMINATION (1) B. EXHAUST TERMINATION (1) C. FRESH AIR GASKET 4IN (1) D. EXHAUST GASKET 2.5IN (1) E. BOILER GASKET (1) F. 90 DEG ELBOW (W/ FLANGE) (1) G. FLANGE SCREWS (4) H. WALL GASKET (1) I. WALL GASKET (1) Notes: Length 1 to 8.8 equivalent length 90 Elbow = 3.3 equivalent length 45 Elbow = 1.6 equivalent length 10

Standard Concentric Vent Kit Installation Drill the wall in the chosen position. Useful measurements concerning the position of the pipes and the limit lengths are enclosed in the mounting bracket instructions and in the documents enclosed with the boiler. If it is necessary, cut the pipes A and B from the elbow side. Figure 1 The maximum measurements you can obtain with this kit is shown in the illustrations. 36 6 4.5 29 2 Figure 2 Insert pipe B and pipe A through the hole in the wall with the terminal protruding out not less than the indicated measurement. 6 Figure 3 Install the wall gaskets H and I on pipe A. The plastic wall gasket H must be fitted inside, the rubber wall gasket I must be fitted outside the building. Figure 4 11

Standard Concentric Vent Kit Installation Cont. Fit gasket E to the boiler. Insert the elbow F between the exhaust pipe and the boiler. Be careful not to damage the gaskets inside the elbow. Figure 6 Fix the elbow F on the boiler using the screws G. Figure 7 12

Concentric Vent Accessories (For use with riser and standard concentric kits) Concentric Extension - RI PLUS VC EXT - 10999.0388 Equivalent Length: 3.3 A. INTAKE PIPE (38 ) B. EXHAUST PIPE (38 ) C. FRESH AIR GASKET 4IN (1) D. EXHAUST GASKET 2.5IN (1) Concentric 90 Degree Elbow - RI PLUS VC 90-10999.0390 Equivalent Length: 3.3 A. 90 CONCENTRIC ELBOW (1) B. FRESH AIR GASKET 4IN (1) C. EXHAUST GASKET 2.5IN (1) Concentric 45 Degree Elbow - RI PLUS VC 45-10999.0391 Equivalent Length: 1.6 A. CONCENTRIC ELBOW (1) B. FRESH AIR GASKET 4IN (1) C. EXHAUST GASKET 2.5IN (1) 13

Separate Vent Kit - RI PLUS VS - 10999.0393 A. WALL GASKETS (4) B. FLUE EXHAUST PIPE (39 ) C. PIPE GASKETS (4) D. 90 DEG ELBOW (2) E. AIR INTAKE PIPE (39 ) F. INTAKE COLLAR (1) G. EXHAUST COLLAR (1) H. COLLAR SCREWS (8) I. BOILER EXHAUST GASKET (1) J. EXHAUST RESTRICTOR (SUPPLIED WITH BOILER) Notes: Maximum length 99 equivalent length 90 Elbow = 3.3 equivalent length 45 Elbow = 1.6 equivalent length 14

Separate Vent Kit Installation The flue exhaust pipe must have a slope of about 1.5 degrees. The termination must be higher than the top of the boiler. 1.5 (1 /3 ) Figure 1 Drill the wall in the chosen position. Useful measurements concerning the position of the pipes and the maximum lengths are included in the documents enclosed in the boiler. Insert the gaskets C into the channels of elbows D and collars G and F. Figure 2 Install the interior wall gaskets A on pipes B and E. Insert the pipes B and E through the holes in the wall. Figure 3 15

Separate Vent Kit Installation Cont. Place the gasket I on the boiler. Secure the flue collar G in place utilizing the four screws H. Be careful not to damage the gaskets. Figure 4 Install the intake collar F using the four screws H. Figure 5 Insert the 90 degree elbows D into the adapters F and G. Slide the intake and exhaust pipes into the elbows D. Complete the installation inserting the wall gasket on the external edges of the pipes. Figure 6 16

Separate Vent Accessories Separate Extension - RI PLUS VS EXT - 10999.0394 Equivalent Length: 3.3 A. INTAKE / EXHAUST EXTENSION (39 ) B. INTAKE / EXHAUST GASKET (1) Separate 90 Degree M X F Elbow - RI VS 90M - 10999.0395 A. 90 DEGREE MALE X FEM. ELBOW (1) B. INTAKE / EXHAUST GASKET (1) Equivalent Length: 3.3 Separate 45 Degree Elbow- RI PLUS VS 45-10999.0396 A. 45 DEGREE MALE X FEM. ELBOW (1) B. INTAKE / EXHAUST GASKET (1) Equivalent Length: 1.6 17

Vertical Roof Vent Kit - RI PLUS RV - 10999.0392 A. ROOF FLASHING - FLAT / PITCHED* (1) B. EXTERIOR TERMINATION (1) C. TERMINATION FLANGE (1) D. TERMINATION MOUNTING SCREW (3) E. FRESH AIR PIPE GASKET (1) F. EXHAUST PIPE GASKET (1) G. EXHAUST ADAPTER (1) H. FRESH AIR ADAPTER (1) I. FRESH AIR COLLAR GASKET (1) J. EXHAUST COLLAR GASKET (1) K. BOILER FLANGE COLLAR (1) L. BOILER FLANGE COLLAR SCREWS (4) M. BOILER FLANGE GASKET (1) * Must be purchased separately. Part numbers can be found on page 22 Notes: Maximum height 27.8 equivalent length 90 Elbow = 3.3 equivalent length 45 Elbow = 1.6 equivalent length Maximum 4 elbows (45 or 90) 18

Vertical Roof Vent Kit Installation Termination Location / Installation: Figure 1 Before installing the roof termination, ensure the proposed location meets the clearance requirements in the boiler installation manual and any local code requirements. 1.5 Figure 1 Standard Roof Vent Height: The standard roof vent kit is 53.5 inches from the top of boiler to the top of the termination. Extensions and elbows can be added, as needed. These parts are shown on page 21. The pitched roof flashing can accommodate a 16 to 41 pitch, as shown in figure 2. Note: The roof flashing (pitched or flat) must be purchased separately. 53.5 in Figure 2 Termination Installation : Slide the termination flange (C) onto the termination pipe (B) as shown in figure 3. Align the roof flashing (A, purchased separately) with the hole cut through the roof. Slide the termination (B) down through the flashing and hole through roof until the termination flange (C) fits securely on the roof flashing. Figure 3 Figure 4 19

Vertical Roof Vent Kit Installation Cont. Gasket Installation : Insert the gaskets (E,F,I,J) into the corresponding adapters as shown in figure 5. Be sure to install the gaskets so the bevels of the gasket are oriented as shown. Boiler Collar Installation : Figure 6 Install the boiler flange gasket (M) onto the outlet of the boiler. Attach the boiler flange collar (K) to the boiler using the 4 screws (L). Slide the adapters (G, H) into the flange collar (K). Be sure not to damage the gaskets. Termination connection : Slide the termination or extension (if used) into the adapters (G, H) as shown in figure 7. Figure 5 Figure 6 Figure 7 Final Installation : Once the exhaust pipe has been connected to the boiler, installation is completed by sliding the termination flange (C) down onto the roof flashing (A). Secure the flange with the three supplied screws (D) as shown in figure 8. Figure 8 20

Vertical Roof Vent Accessories Vertical Roof Vent Extension - RI PLUS RV EXT - 10999.0407 Equivalent Length: 3.3 A. INTAKE EXTENSION (39 ) B. EXHAUST GASKET (1) C. INTAKE GASKET (1) D. EXHAUST EXTENSION (39 ) E. CENTERING BRACKET (1) Vertical Roof Vent 90 Degree Elbow - RI PLUS RV 90-10999.0408 Equivalent Length: 3.3 D C A B A. EXHAUST PIPE (1) B. INTAKE PIPE (1) C. INTAKE GASKET (1) D. EXHAUST GASKET (1) Vertical Roof Vent 45 Degree Elbow- RI PLUS RV 45-10999.0409 Equivalent Length: 1.6 A. EXHAUST PIPE (1) C B. INTAKE PIPE (1) D C. EXHAUST GASKET (1) B D. INTAKE GASKET (1) A 21

Vertical Roof Vent Accessories Cont. Vertical Roof Vent Flat Flashing - RI RV FF - 10999.0280 Vertical Roof Vent Pitched Flashing - RI RV PF - 10999.0252

23

24