Safeguarding Applications and Wiring Diagrams Cat 1 Stop with Guardlocking Interlock and Proximity Sensors TLSZR-GD2, 872C, GLP, PowerFlex 45

Similar documents
Safety Application Note

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Power Supply

3-36. General 1-2-Opto-electronics 3-Interlock. Switches. Operator. Interface. Logic Power. Safety Switches Guard Locking Switches 440G-MT

Palletiser Functional Safety Specification

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Safety Contacts. Locking Type. Power Supply. Operating Radius, Min

NHP SAFETY REFERENCE GUIDE

Safety Control HR1S-AC. Safety Relay HR1S-AC

APPLICATIONS. The SAFEasy TM SG2 light curtains represent the natural evolution of the

Operator Interface 4-1. General. Safety Switches. 4-Table of. Contents. Logic. Power. Operator Interface Table of Contents. 2-Opto-electronics

APPLICATIONS. Automatic assembling lines Palletizers and Depalletizers

Inputs Safety Outputs Auxiliary Outputs Terminals Reset Type Power Supply Cat. No. Fixed. Block Diagram Y41 MSR30RT/RTP

Sequential logic implementation

Advanced Battery Charger. 3 - stage charging capability (IUoU) 25A

Specifications. Standards. Category. Certifications. Power Supply. Connection Wire Length, Max. Detection Weight. Wire Size

Safety Exhaust Valve Integration Guide

Welcome to the presentation about safety functions of ACS880 functional safety, FSO- 12 Safety functions module.

Operator Interface 4-1. General. Safety Switches. 4-Table of. Contents. Logic. Power. Operator Interface Table of Contents. 2-Opto-electronics

IDEM Solenoid Interlock Safety Switches

Emergency lighting units EM powerled

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Safety Contacts. Auxiliary Contacts. Actuation Speed, Max.

Possible to create the highest level safety system

Safety Sensor CSS 180 Product Information

FS1A Safety Controller

GE FANUC Parts. VersaPoint Power Terminal. Segment Terminal Fused, with Diagnostics 24VDC IC220PWR013. Features. Ordering Information

Note: Read this manual carefully before installing the operator and place this installation manual in an accessible place near the operator.

Advanced Battery Charger 0 ~ 15A 0 ~ 25A 0 ~ 35A 0 ~ 50A 0 ~ 80A. 3 - stage charging capability (IUOU) 90 ~ 264VAC (refer to de-rating curve)

FT-10 Network Digital I/O Module Kits and

Universal Gate Box with Safety Interlocking TYPE: UGB-KLT FEATURES & APPLICATION:

Technical data. Standards: IEC/EN , EN ISO , IEC 61508, IEC

Cat N 3. OVERALL DIMENSIONS

Advanced Battery Charger. 3 - stage charging capability (IUOU) 4.1 A / 100VAC 1.8A / 240VAC

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

SensaGuard TM 18 mm Stainless Steel Barrel Installation Instructions

Safety door-handle system STS

Emergency lighting units EM powerled

DLKEK3HN INSTALLATION INSTRUCTIONS

Senior Swing Control Box. Table of Contents

Emergency lighting units EM powerled

pg. 2 Using Sensing Edges in Safety Applications How sensing edges work Understanding the fail-safe concept

GENSET CONTROL MODULE A121A / A241A

224-EN WIRELESS CONTROLLER INSTALLATION & INTERFACE GUIDE. Guide No. 224-EN USING AS REPLACEMENT CONTROLLER

Heavy-Duty Safety Interlock Switch with Guard Door Locking

General Purpose Incremental Encoder

Flight Systems. Replacement for KASSEC DESCRIPTION

4 relays DIN actuator

USERS GUIDE LO-21U LOCKOUT RELAY

Close-Open (Short-Circuit) Time Results Interpretation

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

Technical specification. POW12V20A-D1 Charger. LFP/LTO + BMS connector

PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22.

INSTRUCTION INVERTER COMPACT FOR SLIDING GATES /R0 10/11/2017

INSTALLATION GUIDE. FCC ID NOTICE

3200NT Timer Service Manual

SHIVVERS ROTATION DETECTOR. fshiwersf ROTATION DETECTOR 676A-001A

Installation and Maintenancee Manual

TTT802 Gearshift Controller, Part # R1N-S (Standard), -P (Paddleshift)

GENSET CONTROL MODULE LEVEL 1 A121CM / A241CM. Special logic to re-establish cranking following a false start.

Tina 10A/B/C Adaptor unit

Controller Test Procedure

ThinkTop DeviceNetTM VDC DeviceNet is a Trademark of the Open DeviceNet Vendor Association, Inc. (ODVA).

Emergency lighting units EM series

GUIDE 200.V2 VSD VERTICALLY CONTROL SYSTEM & INTERFACE GUIDE. 202 Standard Operation 202 Slave Mode 201 Sequence of Operations

2 WAY REMOTE STARTER & ALARM SYSTEM INSTALLATION GUIDE FCC ID NOTICE

Instruction Bulletin. Enclosed ALTISTART 46 Controller Supplemental Instruction Bulletin Class 8638 and 8639 INTRODUCTION

CTi Automation - Phone: Fax: Web:

Emergency lighting units EM powerled

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

Programmable 8 Channel Injector Driver Module

Safety Door Handle System with SIDENT Safety Switch Ref. no , -11, -12

Gate Box with Safety Interlocking & RFID UGB-KLT Operating Instructions

Redundant Control System

CAUTION CM-SE CM-S21 CM-S41

NHP SAFETY REFERENCE GUIDE

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series

Starting System DS-102 Series 200. Elmatik AS P.O.Box 309 NO-3471, Slemmestad T F

Emergency lighting units EM converterled. EM converterled PRO 50 V PRO series

5000 SERIES POWER SUPPLY/CHARGERS INSTALLATION GUIDE

4 Redundant Control System

SPECIAL DUST EXPLOSIVES ATMOSPHERES

231.V1 GUIDE VSD. CONTROL SYSTEM & INTERFACE GUIDE C/W TDP (Total Door Protection) Dual Light Curtains

Hall Coded Non-contact Safety Switches. Model Number Structure

MANUAL. MiniMax V / VK

Button 1 Button 2. Button 3 Button 4. Programmed Remote Transmitter. Button Function Condition

Field Commander Lite Wiring Manual

FAST XIM. XIM Unit Installation

P33T Series Redundant Safety Exhaust Valve ENGINEERING YOUR SUCCESS.

Sorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes

FMC-1/2 Tina Muting unit

Emergency lighting units EM Inverter. EM SELFTEST G2, V SELFTEST version

Emergency lighting units EM series. EM PRO EZ-3, V PRO version

EC DECLARATION OF CONFORMITY

Contents. Part no.: MLC510R Safety light curtain receiver

Solenoid interlock AZM 200 The non-contact interlock.

SiCan Simple CAN Extension Charger to PacMon

IDEM MPC Non-Contact Coded Magnetic Safety Switches MPC Series Plastic Housing

Technical Data Accessories MCBs Ex9B.

INSTRUCTION MANUAL H WELDER INTERLOCK

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

MDC V, 30A Brushless Controller. User s Guide L East Orangefair Lane, Anaheim, CA

Transcription:

Cat with Guardlocking Interlock and TLSZ-GD, C,, PowerFlex 5 + VDC eset & Lock PowerFlex 5 LL L Brown ed Yellow Green Grey Pink White Blue TLSZ-GD D-FAC- X X 5 S5 S Y 6 -GLSP S S L5 5 A P P AX L Gnd S S control power supply control circuit C-DNP-D D-FAC- V DC Com The gate is closed and locked. The motor is off. The is ready for reset. The has a Logic setting of : (Category with Logic IN OFF), a Safe Limited Speed (SLS) setting of (Hz) and a aximum speed setting of (Hz). The safety outputs (X & X), the single wire safety output (L) and the auxiliary output (Y) are OFF. NOTE: the logic configuration from to configure X and X for use as safety outputs. STATING: Press the reset button to lock the gate and turn the safety outputs ON. Press the button to turn the motor ON. STOPPING: Normal production stopping is performed by pressing the button. Access through the safety gate is initiated by pressing the button. The Y output of the turns OFF and initiates a stop command to the drive. When the speed detected by the proximity sensors drops below the safe limited speed, the gate becomes unlocked and the safety outputs turn OFF. The PowerFlex drive goes to a safe off state. If the motor has not already stopped, the motor coasts to a stop. OVESPEED: If the proximity sensors detect a speed greater than the maximum speed (Hz), the auxiliary output (Y), the safety outputs (X & X) and the single wire safety output (L) turn off. The PW/Fault indicator flashes at a X rate. When the speed drops below the max speed limit, press the eset button to clear the fault. Upon power-up, the safety devices perform internal checks. The TLSZ has OSSD outputs and checks for crossfaults. The safety outputs are pulse tested to check for faults. The proximity sensors are continuously tested by requiring that both sensors cannot be OFF at the same time. The PowerFlex 5 performs its own internal safety checks, and requires two safety signals to enable the drive. atings The safety function meets the safety performance requirements of SIL CL per IEC 66:5 and has a Category structure that can be used in systems requiring Performance Levels up to PLd per ISO-:. This circuit executes a Category stop. - -

+ VDC Safeguarding Applications and Wiring Diagrams Cat with Guardlocking Interlock and TLS-GD, C,, PowerFlex eset & Lock L L L S T PowerFlex X X 5 S5 S Y L A 5 5 -GLSP S S L5 A P P AX L DC Comm Digital In Com TLS GD G-T Status C-DNP-D D-FAC- emove Jumper U V W V DC Com The gate is closed and locked. The motor is off. The is ready for reset. The has a Logic setting of : (Category with Logic IN OFF), a Safe Limited Speed (SLS) setting of (Hz) and a aximum speed setting of (Hz). The safety outputs (X & X), the single wire safety output (L) and the auxiliary output (Y) are OFF. NOTE: the logic configuration from to configure X and X for use as safety outputs. STATING: Press the eset button to lock the gate and turn the safety outputs ON. Press the button to turn the motor ON. STOPPING: Normal production stopping is performed by pressing the button. Access through the safety gate is initiated by pressing the button. The Y output of the turns OFF and initiates a stop command to the drive. When the speed detected by the proximity sensors drops below the safe limited speed, the gate becomes unlocked and the safety outputs turn OFF. The PowerFlex drive goes to a safe off state. If the motor has not already stopped, the motor coasts to a stop. OVESPEED: If the proximity sensors detect a speed greater than the maximum speed (Hz), the auxiliary output (Y), the safety outputs (X & X) and the single wire safety output (L) turn off. The PW/Fault indicator flashes at a X rate. When the speed drops below the max speed limit, press the eset button to clear the fault and energize the safety outputs. Upon power-up, the safety devices perform internal checks. The TLS has dual channel signals but does not checks for crossfaults. The safety outputs are pulse tested to check for faults. The proximity sensors are continuously tested by requiring that both sensors cannot be OFF at the same time. The PowerFlex requires two safety signals to enable the drive. atings The safety function meets the safety performance requirements of SIL CL per IEC 66:5 and has a Category structure that can be used in systems requiring Performance Levels up to PLd per ISO-:. This circuit executes a Category stop. - -

Category with Guardlocking Interlock and TLS-GD, F, C,, DIS, PowerFlex + VDC L L L eset & Lock F-TXV PowerFlex S T E- A 5 5 X X 5 S5 S Y L -GLSP S S 5 A AX P P L S S S S S S Y DIS -DS L L A S Status eset DC Comm Digital In Com TLS GD G-T Status C-NP-D D-FAC- emove Jumper U V W V DC Com The gate is closed and locked. The motor is off. The is ready for reset. The has a Logic setting of : (Cat with Logic IN OFF), a Safe Limited Speed (SLS) setting of ( Hz) and a maximum (AX) speed setting of ( Hz). Both E-s are closed. The DI is configured to setting [(IN AND IN) AND L] with monitored manual reset). NOTE: the logic configuration from to configure X and X for use with safety inputs. STATING: Press the eset button to turn the safety output (L) ON. This enables the DI relay. Press the eset button to turn the DI outputs ON and enable the Safe-Off Option of the PowerFlex Drive. Press the button to turn the motor ON. STOPPING: Normal production stopping is performed by pressing the button. Access through the safety gate is initiated by pressing the button. The Y output of the turns OFF and initiates a stop command to the drive. When the motor speed drops below the safe limited speed, the unlocks the gate and turns its L safety output OFF. Subsequently the DI turns its safety outputs off, and the PowerFlex drive goes to a Safe-Off state. The motor, if not already stopped, coasts to a stop. The E-stop buttons can be used to initiate a coast-to-stop. Press the e-stop and the DI outputs turn off, which causes teh PowerFlex drive to execute a Safe-Off function. The motor coasts to a stop. Upon power-up, the safety devices perform internal checks. The sends out test pulses on X & X to check for faults on the guardlocking switch. The DI sends out test pulses on S & S to check for faults on the e-stops. The checks to see that the proximiity senors are connected, by requiring that both sensors cannot be OFF at the same time. The L/L connection is Single Wire connection tested for shorts to power or ground when active. The DIS outputs & are pulse tested to check for shorts to power and ground. The DIS outputs &, which are not pulse tested, should be used for compatibility with devices that cannot tolerate the pulse testing. atings The safety functions meet the safety performance requirements of SIL CL per IEC 66:5 and has a Category structure that can be used in systems requiring Performance Levels up to PLd per ISO-:. This circuit executes a Category stop when requesting gate access through the, and a Category stop when pressing the e-stops. - -

Safe Limited Speed with Guardlocking Interlock and TLSZ-GD, T,, PowerFlex + VDC L L L eset & Lock PowerFlex VDC S T V DC Com Brown ed Yellow Green Grey Pink White Blue TLSZ-GD D-FAC- X X 5 -GLSP S S L5 S5 S Y A P P L AX L T-DHNP-D D-FAC- Speed Select DC Comm Digital In Com emove Jumper U V W The gate is closed and locked. The motor is off. The is ready for reset. The has a Logic setting of : (Safe Limited Speed with Logic IN OFF), a Safe Limited Speed (SLS) setting of 5 (5Hz) and a aximum speed setting of (Hz). The safety outputs (S & S), the single wire safety output (L) and the auxiliary output (Y) are OFF. NOTE: the logic configuration from to configure X and X for use as safety outputs. STATING: Press the eset button to turn the safety outputs and single wire safety output ON. Press the button to turn the motor ON. STOPPING: Normal production stopping is performed by pressing the button. Access through the safety gate is initiated by pressing the button. The Y output of the turns ON and commands the PowerFlex drive to bring the motor to a safe slow speed (less than 5Hz). When the speed detected by the proximity sensors drops below the safe limited speed (5Hz), the gate becomes unlocked. The operator can enter the machine cell, as the motor continues to run at the safe slow speed. After leaving the cell and closing the gate, press the reset button to lock the gate and return the machine to production speeds. Upon power-up, the safety devices perform internal checks. The TLSZ has OSSD outputs and checks for crossfaults. The safety outputs are pulse tested to check for faults. The proximity sensors are continuously tested by requiring that both sensors cannot be OFF at the same time. The PowerFlex requires two safety signals to enable the drive. If the gate is unlocked and the motor speed increases beyond the safe limited speed, the turns its safety and single wire safety outputs OFF. OVESPEED: If the proximity sensors detect a speed greater than the maximum speed (Hz), the safety and the single wire safety outputs turn OFF. The PW/Fault indicator flashes at a X rate. When the speed drops below the max speed limit, press the eset button to clear the fault. atings The safety function meets the safety performance requirements of SIL CL per IEC 66:5 and has a Category structure that can be used in systems requiring Performance Levels up to PLd per ISO-:. This circuit executes a Safe Limited Speed function. - -

Safe Limited Speed with Guardlocking Interlock and TLS-GD, F, C,, DI, PowerFlex 5 + VDC eset & Lock E- F-T F-XS eset PowerFlex 5 +V DC L L L A 5 5 X X 5 S5 S Y L -GLSP S S 5 A AX P P L S S S S DI -D S S L L A S Y Dig Input (Speed Select) Gnd control power supply control circuit S V DC Com TLS GD G-T Status C-DNP-D D-FAC- Status S The gate is closed and locked. The motor is off. The is ready for reset. The has a Logic setting of : (Safe Limited Speed with Logic IN OFF), a Safe Limited Speed (SLS) setting of ( Hz) and a maximum (AX) speed setting of ( Hz). Both E-s are closed. The DI is configured to setting [(IN AND IN) AND L] with monitored manual reset. The single wire safety output (L) and the auxiliary output (Y) are OFF. The DI safety outputs are off and the DI auxiliary output (Y) is ON. NOTE: the logic configuration from to configure X and X for use with safety inputs. STATING: Press the eset button to turn the safety outputs (L) ON. This enables the DI relay. Press the eset button to turn the DI outputs ON and enable the PowerFlex Drive. Press the button to turn the motor ON. STOPPING: Normal production stopping is performed by pressing the button. Access through the safety gate is initiated by pressing the button. The Y output of the turns ON and commands the PowerFlex drive to bring the motor to a safe slow speed (less than Hz). When the speed detected by the proximity sensors drops below the safe limited speed (Hz), the gate becomes unlocked. The operator can enter the machine cell, as the motor continues to run at the safe slow speed. After leaving the cell and closing the gate, press the reset button to lock the gate and return the machine to production speeds. The E-stop buttons can be used to initiate a coast-to-stop. Press the e-stop and the DI outputs turn off, which commands the drive to a safe off state. The motor coasts to a stop. Upon power-up, the safety devices perform internal checks. The sends out test pulses on X and X to check for faults on the guardlocking switch. The DI sends out test pulses on S and S to check for faults on the e-stops. The checks to see that the proximiity senors are connected, by requiring that both sensors cannot be OFF at the same time. The L/L connection is Single Wire connection tested for shorts to power or ground when active. atings The safety functions meet the safety performance requirements of SIL CL per IEC 66:5 and has a Category structure that can be used in systems requiring Performance Levels up to PLd per ISO-:. This circuit executes a Safe Limited Speed function when requesting gate access through the, and a Category stop when pressing the e-stops. - 5 -