Spare Parts KPC 115-L-U/S, KPC115-L-S

Similar documents
H:\SC218\17_Ersatzteile\Spare Parts SC 218.doc

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101

Item Code Description Quantity 3NA LV HRC FUSE LINK S00 80A 690AC 250DC 30 3NA3832 LV HRC FUSE LINK GL/GG S00 125A 500VAC 250VDC 0

SIRIUS Innovations. Technical information for ring terminals SIRIUS. Answers for industry.

Stars or starlets? Competitor overview switching devices. Only for internal use. sirius IN COMPARISON

Protection Equipment. 5/2 Introduction

IEC Power Control SIRIUS. Motor Starter Protectors. Revised 04/20/15. Section Overview... 1/2-1/3. Motor Starter Protectors

COMPACT RACK TYPE DISHWASHER

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

Air-to-water heat pump for indoor installation - LIK 8TES. Spare parts list

3VF3 to 3VF8 Circuit-Breakers

Motor Starter Protectors

Motor Starter Protectors

22AF 40AF AF 150AF 225AF 400AF 800AF

Eclipse 2000 Service Parts

QOF-2/3/5/7.5. Parts Manual. Direct Drive Oil-free scroll compressors. Manual No November 2014 Edition

Millennium TM. 100 thru 675 Tons (315 thru 2375 kw) renewal parts. Supersedes: RP1 (1099) Form RP1 (710) R-22 and R-134a 00202VIP

HEAVY DUTY POWER RELAYS FEATURES

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Parts List. Stackable Crescent Cuber. Models KM-1601MRJ/3. hoshizakiamerica.com

Wash and rinse systems. Page 2. Various and air traps. Page 5. Drain and filter systems. Page 6. Door and hood components. Page 9

mono-mix Contents Complete Equipment with Scope of Supplies 3 Accessories 4-5 Spare Parts

Hoshizaki America, Inc.

UMBW-UL489 and UL1077 Listed

SIRIUS 3RU2 Thermal Overload Relays

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Low-Voltage Motors N-compact Standardline Operation on supply system

Overload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview

DUCT type. SPLIT TYPE AIR CONDITIONER (50Hz) Models Indoor unit Outdoor unit C O N T E N T S

27Overload Relays. Overview Combinations of overload relays and contactors SIRIUS 3R. Thermally delayed overload relays CLASS 10

General data 5/37. Overview

REF : 30XA1502 STD UNIT MODULE1:CKTA,CKTB MODULE 2:CKTC

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Prodigy Eclipse 600, 800, 1000 Service Parts

TWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw

Ktec Contactors and thermal overloads

3VU13, 3VU16 Circuit-Breakers

KEY PART # DESCRIPTION KEY PART # DESCRIPTION

1 Phase electronic contactor (SC 1)

3 - Protection components Motor circuit-breakers

KEY PART # DESCRIPTION KEY PART # DESCRIPTION

Electric expansion valve stepper motor. Controller for elec. expansion valve Connector for controller expansion valve

Command and signalling E 250, E 259 selection table

MDT5N25 & MTD5N40 SERVICE PARTS

Operating manual LPS. Humidifies and Cools. ÁLPS.ENzÈ LPS.EN

REPLACEMENT PARTS MANUAL

Spare parts Catalogue number

Order No. of the options EMC filter Class A

CATALOG OF REPLACEMENT PARTS

Micro Contactor MA Series

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Components for EEx e Panels

ATL 12 ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. La =Lc + Stroke Lc T. Rear bracket SP. Stroke. Capacitor

Westinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975

Prodigy Eclipse 600, 800, 1000 Service Parts

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Thermal Overcurrent Circuit Breaker 3120-F...

Wiring Diagrams (Including Accessories) (50/60 Hz)

WATER SOURCE HEAT PUMPS REPLACEMENT PARTS MANUAL MODELS: General Notes. Contents. Important

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

No. F ISSUED: Jul. 1, 2010 REVISED: Nov. 26, 2013 HOSHIZAKI MODULAR CRESCENT CUBER KMD-270AA MODEL

Westinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975

NR2 Thermal Overload Relay. 1. General. 2. Type Designation. 3. Features. Relays. EU Germany Ukrain Russia South Africa USA

Thermal Overcurrent Circuit Breaker 3120-F...

Hoshizaki America, Inc.

PL Split Indoor Units (RoHS application) CDKS30JVLT CDKS40JVLT CDXS30JVLT CDXS40JVLT

Direct solenoid and solenoid pilot operated valves

Protection Equipment

Parts List Book CPE CPVS

SPLIT TYPE AIR CONDITIONER (50Hz) DUCT type

Hoshizaki America, Inc.

Thermal Overcurrent Circuit Breaker 3120-F...

KEY PART # DESCRIPTION KEY PART # DESCRIPTION

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Hoshizaki America, Inc.

C1448, C1848, C2148 Service Parts

SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE

Prodigy Eclipse ECC, EH330 and EH430 C or D Service Parts

Hoshizaki America, Inc.

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

McQuay. Thermal Systems Absorption Chiller ME, MF Vintage A. Last Manufactured: Replacement Parts List No New 05/2001

Mobile Diesel Heaters GRY-D / GRY-I Service Training Course

QUANTUM SERIES JUICE DISPENSER

CONTINUOUS CAPACITY CONTROL MODELS

Power Supplies. 11/2 Introduction

BITZER Liquid Injection Guidelines for CSH Compressors

Electrical Control Valves

Approved Standards. Ordering Information. Thermal Overload Relay J7TKN. Model Number Legend. Thermal Overload Relay. Accessories

Parts List. Modular Cubelet Serenity Series Models FS-1500MLH-C. hoshizakiamerica.com

McQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018

Partnership that you can trust. LV Switchgear Motor Control Products.

McQuay. Enfinity Ceiling Mounted Water Source Heat Pump. WCCH, WCCW 019, 024 Design 1. Last Manufactured: 2008

TECHNICAL CATALOGUE SELF CONTAINED HORIZONTAL AIRCONDITIONERS Rev105

AIR-CONDITIONER SERVICE MANUAL. RBM-Y1034F-PE (3-way) 3-PIPE SUPER MULTI, HEAT PUMP WITH SIMULTANEOUS HEATING AND COOLING. RBM-Y1044F-PE (4-way)

List of Parts for Screw Compressor VMY 447 H and VMY 447 M Model 1994

BALL SCREW LINEAR ACTUATOR OVERALL DIMENSIONS LENGTH

CATALOG OF REPLACEMENT PARTS C24GA6 & C24GA10 GAS CONVECTION STEAMERS PRIOR MLS COVERED IN THIS MANUAL

Transcription:

KPC 115L-U/S, KPC 115L-S page 1 / 16 Version: V2016-11

1 or 2 5 3 or 4 7 9 7 6 13 13 page 2 / 16 Version: V2016-11

16+17 PT100 42 14 44 43 12 11 10 18 19 13 15 page 3 / 16 Version: V2016-11

number description 1 type electrical item designation number scheme SAP PDS remarks air bleeder automatic (Braukmann 1/8-3/8) EA122 54632 SEB 141 65493601 382002 2 air bleeder automatic (Braukmann Messing/brass)10bar 141 65493301 381001 2a socket for air bleeder No.:2 141 65493401 381010 3 water heater 230V/800W 1661/0105 5E1 163 65060001 212201 4 water heater 230V/800W 5E1 163 the same as Pos: 3 5 high pressure rotary pump 480V/60Hz CR3-9U 6M1 100 65530801 387109 IE3??? 5a high pressure rotary pump 400V/50Hz CR3-12 6M1 100 65531801 387119 IE3??? pressure gauge 0-6 bar 1/4" M 6386H or 1484.074.003 water 6 connection rear 0-6 bar 37 65494301 383041 7 straight thermometer 110x30mm G3200 0-50 C 134 65498001 384031 8 angle thermometer 110x30mm W3201 0-50 C 134 65497901 384030 pressure gauge water 0-10 bar 1/4" M 63810 or 1482.075.003 9 connection lower 0-10 bar 1/4" water 37 65493801 383002 10 safty valve 6bar 3/4" - 1" SVS206 or 28578 108 65457101 374100 air fix & relief valve (241100) 11 (shut off valve 3/4" for-expansion tank) KV 2020 125 65465701 376101 12 expansions receiver A25 Airfix 104 65458501 375020 13 ball valve (drain and fillin valve red handle bar) KFE DN 15 (KFEKV) 128 65445101 371100 TA-balance valve (flow regulating valve) 14 without insulation STAD DN 25 111 65433101 369022 15 flow-control Sika-VHS07M2KKTKR01 7B1 137 65471701 377122 Origin Label 16 temperature sensor TF PT-100 ID-Nr. 195685 (4m) 8B1 138 65878301 453011 please order KKT- 65124601also page 4 / 16 Version: V2016-11

electrical item number number description type designation scheme SAP PDS remarks please order 17 swagelock screw connection 1/4" B-6M0-1-4RT BT 65124601 314001 KKT-65124601 also 18 filter strainer SFM32 122 65462901 376004 19 ball valve with handle MLG - V 032-7 124 65446101 371134 page 5 / 16 Version: V2016-11

38 37 40 50a,50b,50c 36 32 33,33a,33b 35 page 6 / 16 Version: V2016-11

Located behind the compressor: 41 48 45 46 47 49a,49b,49c page 7 / 16 Version: V2016-11

60 65 70 60 67 page 8 / 16 Version: V2016-11

page 9 / 16 Version: V2016-11 number scheme [C4175] SAP PDS remarks number description type electrical item designation 32 bullet casing heating 240V (ZR 90 - ZR 19) 65994001 501856 ZR 16 M3E TWD 561 winding protector(int69) 9M1 1 65986201 501123 Not available 33 compressor 33 compressor ZR160KCE-TFD650 67058501 Compressor replacement Kit for ZR160 928034 ZR 19M3E TWD 561 winding protector(int69) 9M1 1 65986301 501124 Not available 33a compressor 33a Compressor ZR190 6700586 Compressor replacement kit for ZR190 928040 34 shutt off valve (refrigerant circuit) 6012/22 (180020) 66092901 532426 35 pressure switch dual mode (Alco) PS2-C7A PCN: 4353500 9B1 38/39 66056901 525130 Origin Label 36 compressor protection equipment motor protection INT 69, 24 V AC 50/60Hz 65995001 501902 37 low pressure gauge 111.60.00.02384 or 110-063-D-000004-1/ 9 bar cold 37 66115601 544001 111.60.00.02383 / 110-063-D-000003-1/ 32 bar cold 37 66115701 544002 38 high-pressure gauge 40 Evaporator M 25 x 40 GL 3 66159801 580914 41 check valve (non return valve refrigerant) NRV19 S22 020-1054 10 66082901 532052 42 shutt off valve (refrigerant circuit) 6420/M10 66090401 532400 ASC-24VAC (VDE 0580) PCN:801 062 10Y1,10Y2 16 66042601 522050 Origin Label 44 alco solenoid coil / AC 45 magnetic valve without coil 200RB6T5 (PCN801186) 16 66041101 522006 Origin Label 47 filter-dryer 16mm ADK-Plus 165 32 66067901 530025 49a alco angle flange 16x22mm A 576 17 66032801 515383 49b alco cage assembly (inlet) X22440B7B 17 66028201 515307 49c alco power assembly (TOP) XB 1019MW-1B 17 66022101 515200 Origin Label 60 condenser fan 400V/50Hz D/Y 460V/60Hz D/Y FE 050-VDD.4.1.6/UL 11M1, 11M2 65052401 207020 Origin Label 65 fan-mounting plate (small nozzle) 00342657 65055901 207901 67 fan-mounting plate (nozzle) 00284886 65056101 207903 70 condenser refrigerant SIGLA V24+200 Typ 2522 C01 460422141023A 4 66155101 573121 75 wind guard/wind baffle f. KPC115-66582301 802701 without picture

electrical item number number description type designation scheme SAP PDS remarks 49a alco angle flange 16x22mm A 576 17 66032801 515383 49b alco cage assembly (inlet) X22440B7B 17 66028201 515307 49c alco power assembly (TOP) XB 1019MW-1B 17 66022101 515200 Origin Label 49a alco angle flange 12x16mm A 501-7 17 66033301 515388 49b alco cage assembly (inlet) X 22440-B3,5B 17 66027801 515303 49c alco power assembly (TOP) XB1019 GL 2B 17 66026901 515291 Origin Label page 10 / 16 Version: V2016-11

e100 e101 e102-filter Pos.: e115 LED-lamp-red (10 pcs.) e116 LED-lamp-white (10 pcs.) e103 e105 e104 e106 e107 e108-filter e109 page 11 / 16 Version: V2016-11

e150 e121 e152 e120 e154 e122 e156 e123 e160 e158 e124 e162 e125 e164 e163 e164 e162 e166 e131 e132 e170 e132 e180 e171 e132 e191 e132 e181 e183 e133 e182 e190 e135 e140 e142 e143 page 12 / 16 Version: V2016-11

number description type electrical item designation number scheme [C4175] SAP PDS remarks from serial.017. Origin Label until serial.017. Origin Label e100 six-stage thermostat (old typ..nw...) ST710-PWHVM.26 8N1 65901501 459100 e100 temperature controller (Elliwell) EWPC 905/T1C2BCC500 8N1 65784601 445401 e101 plastic-grating IP 54 105 x 105 x 22 mm 100030 66582501 802731 e102 exchange filter for PF/PFA 1000, 85 x 85mm 150g/m2 66489501 692010 e103 push-button-red 1Ö Ba9s 3 SB 3207-0AA21 7S2 65696401 423150 e104 push-button-red 1Ö Ba9s 3 SB 3207-0AA21 7S1 65696401 423150 e105 pushbutton lampholder BA9S red, complete unit (rund illuminated) 3SB 3204-6AA20 7S1 65690901 423001 e106 control switch (Remote/ON/OFF) panel mounted U1/8ZM/NS/X70A/F643 6S1 67066101 e107 main switch NLT40/3E/Z33/X72/F803 4Q1 65618101 405101 Origin Label e108 e109 e115 e116 e120 exchange filter for PF/PFA 2000, 115x115mm 350g/m² 66489601 692011 cabinet fan IP54 150x150x71 with UL 230VAC (100014) FPF12KR230BE-110 5M1 66582901 802751 Origin Label accessories for 3SB3 LED lamp, base BA 9S 24V AC/DC, red packing (preferred type) 4153092411 65693101 423034 10 pieces accessories for 3SB3 LED lamp, base BA 9S 24V AC/DC, white (preferred type) 3SB 3901-1QA 65693301 423036 10 pieces transformator 24V 160 VA Primär : 208...550 V Sekundär : 24 V EN 61558 4AM3842-8DN00-0EA0 4T1 65681301 421011 Origin Label e121 Earth-clamp 24...48V e122 GTF 76/48 3121025 4A2 65558001 401150 min. cicuit breaker 400V 6KA, B-characterist., 1 pole, 6 A/ N-Type AC 1BU6 4F1 65624001 406011 Origin Label page 13 / 16 Version: V2016-11

number description e124 type electrical item designation number scheme SAP PDS remarks cabinet thermostate 0...60 C 1NC (cooling) UL approval 230VAC 1147NO 5B1 66589601 803802 e125 thermistor motor protection standard evaluation unit manual, 1NO+1NC, DC 24V screw connechtion (preferred type) 3RN1011-1CB00 11F1 65699301 423510 Origin Label e131 Compressor time relay start help 3RP1525-1BP30 10K1 65686001 421441 Origin Labe e132 time relay (on-delay) 1W 24/230VAC 3RP1525-1AP30 7K3;7K6 9K4-9K5 65685901 421436 Origin Label e133 time relay (off-delay) 1W 24/230VAC with auxiliary voltage 3RP1505-1AP30 6K2 65685701 421431 Origin Label e135 phase sequence relay ASN2450 42407 4A1 657955B01 445802 Origin Label transformer 230V 1000 VA Primär : 208-550 V 50/60Hz Sekundär : 2 x 115 V e140 EN 61558 4AM5742-8DD40-0FA0 5T1 65681801 421042 Origin Label e142 Earth-clamp 110...230V 10 Stck/Pck GTF 76/230 3121012 5A1 65558101 401151 e143 automatic fuse C4A 1CU4 EN60898 5F1 65624901 406109 Origin Label e150 e152 e154 circuit breaker 20,0...25,0A size S0 motor protection class 10, screw connection, standard breaking capacity (preferred type) 3RV 1021-4DA10 9Q1 65664601 420360 Origin Label circuit breaker 0,7...1,0A, size S00 motor protection class 10, screw connection, standard breaking capacity (preferred type) 3RV 1011-0JA10 4Q2 65661201 420210 Origin Label circuit breaker 2,8...4,0A, size S0 motorprotection class 10, screw connection, standard breaking capacity (preferred type) 3RV 1021-1EA10 5Q1 65662901 420271 Origin Label page 14 / 16 Version: V2016-11

number description type electrical item designation number scheme SAP PDS remarks e158 e160 e162 e163 e164 e166 circuit breaker 3,5...5,0A, size S00 motor protection class 10, screw connection, standard breaking capacity (preferred type) 3RV 1011-1FA10 11Q1 65663101 420280 Origin Label snap on relay 22 E DIN EN 50012 ( 1S / 2 Ö ) size S00 3 RH 1911-1HA12 65668201 420611 slaveswitch 1 - pol 1 Schließer size S0 - S3 with Cage clamp-anschluss contactor AC-3 4KW/400 V AC24V, 50/60 Hz, 3-pole, size S0, screw connection mounting position vertical 3 RH 19 21-2CA10 Nachfolger: 3RH2911-2HA10 3RT 1023-1AC20 Nachfolger: 3RT 2023-1AC20 6K3; 9K3 6K3 65669701 65667601 420661 61112701 65656401 420010 Origin Label contactor AC-3 4KW/400 V 1N0, AC24V, 50/60 Hz 3-pole, size S00 screw connection (prefered type) 3RT 1016-1AB01 4K1 65656501 420011 Origin Label contactor AC-3 15 KW/400V AC 230V 50/60Hz 3-pole, size S2 screw connection (preferred type) 3RT 1034-1AC20 9K3 65659001 420063 Origin Label e170 finder-relay - 14 pol. 55.34.8.024.0040 eg. 6K4 65583001 402004 e171 finder-relay-socket - 14 pol. 94.04.0 eg. 6K4 65586101 402742 e180 cabinet heater 230V/45W spring connection, for mounting rail 35mm UL approval HG140 5E2 657987B01 445901 page 15 / 16 Version: V2016-11

number description type electrical item designation number scheme SAP PDS remarks e182 relay (plug in relay) 24 VAC 8 pol. 2-polig (Finder) without LED 40.52.8.024.00.00 8K1-6 65582701 402001 e183 LED with Varistor 6..24V AC/DC (Finder) 99.02.0.024.98 8K1-6 65588101 402811 e190 frequency inverter 2,2 KW, 5,3A CIMR-E7-C42P21 without EMV-filter 11U1 65963601 464701 Origin Label e191 line-filter for KPC 107/108/115 FS5972-10-07 11A1 65964101 464735 Origin Label e190a Frequency inverter 2,2kW ( replacement Kit ) V1000 & incl. net filter EMV C1 11U1& 11A1 928055 --- remote control panel (EB1546) own making EB1546 66628301 807201 without picture page 16 / 16 Version: V2016-11