Service and Parts Manual. Minimum Filtration Required:

Similar documents
LOAD SENSE SECTIONS. Series 20. Directional Control Valves NEED NEW PIC VALVES STANDARD FEATURES SPECIFICATIONS

General Valve Assembly Information

MP18 Stacking Valve System Technical Information Manual

V050 SERIES DIRECTIONAL CONTROL VALVE

SECTIONAL BODY. Series 20. Directional Control Valves STANDARD FEATURES SPECIFICATIONS VALVES. Pressure Rating

Monoblock Directional Control Valve PMB22TSTSAB PMB23TSTSTSLB PMB21TDLB

4-Way Directional Control Valve With Hydraulic Kick Out

Series 34. Sectional Directional Control Valve Specifications: P34A Engineering & Manufacturing Solutions

MP18/SIC & SIO Stacking Valve System Technical Information Manual

V250 SERIES DIRECTIONAL CONTROL VALVES

CLS100 Proportional Load Sensing Mobile Valve

Full Range Pressure Compensating Variable Flow Control

SERIES 20 SECTIONAL DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE

REPAIR PROCEDURES MANUAL

STANDARD FEATURES. Flow Control Inlet

SERIES Waterman* DESCRIPTION FLOW PRESSURE PAGE NO.

SECTIONAL BODY. Model SV. Directional Control Valves VALVES STANDARD FEATURES SPECIFICATIONS. Parallel or Series Circuit Construction ...

Series PAVC Variable Volume, Piston Pumps

CLS180 Proportional Load Sensing Mobile Valve

Cartridge Valves Technical Information. Spreader Valves. Spreader Valves SCHEMATIC MODEL PRESSURE FLOW* WEIGHT SPR-2FFL12 SPR-2FFLC12 SPR-2FFLW86

HYDRAULICS. TX420 & & lower. Hydraulic Tandem Pump Removal. 4. Remove the LH side panel (Fig. 0388).

liu OIL TRANSFERING BETWEEN

PRESSURE CONTROLS TECNORD

Directional Control Valve

Catalog HY /NA. Catalog HY /NA. Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA

Spreader Valves SPR-2FFL12, SPR-2FFLC12 & SPR-2FFLW86

AF0465-XX SERVICE KITS GENERAL DESCRIPTION MODEL DESCRIPTION CHART OPERATING AND SAFETY PRECAUTIONS THIS MANUAL COVERS THE FOLLOWING MODELS

Large Electronically Adjustable Proportional Pressure Compensated Flow Control Engineering & Manufacturing Solutions

VALVE AND PLUMBING KIT 2409 LOADER CUB CADET & KIOTI TRACTORS

STANDARD FEATURES. Flow Control Inlet

Whisper Pump Service and Repair Guide

Super Charged Piston Pumps Variable Displacement For Open Circuits. PAVC Medium Pressure

MCV106A. Hydraulic Displacment Control-PV DESCRIPTION FEATURES ORDERING INFORMATION. BLN Issued: March 1991

Super Charged Piston Pumps Variable Displacement For Open Circuits. PAVC Medium Pressure

GROUP 3 HYDRAULICS 636 EXTENDO PARTS BOOK

DC Series. 4-Way Directional Control Valve With Or Without Flow Control PDC16T4PBS PDCF16TM454LF

DENISON HYDRAULICS Premier Series. open circuit pump controls P16 B-mod, P09 A-mod. service information

Pressure Control Valves

Heavy Duty Hydrostatic Transmissions

4-Way Directional Control With Pressure Compensated Flow Control PSDCF120M64LF Specifications:

36EFC. Series & EFC Valve Package

ASSEMBLY MANUAL. Keep With Operator s Manual

OPERATION AND PARTS MANUAL

VALVE AND PLUMBING KIT 2408TL LOADER AGCO & MASSEY FERGUSON TRACTORS

VALVE AND PLUMBING KIT INSTRUCTIONS SMC 84Q & 2408 LOADERS NEW HOLLAND TRACTORS MODEL 2WD 4WD LESS CAB WITH CAB 1720 X X X 1920 X X X

KRAC KC-600 PLOW PARTS MANUAL

Solutions. ydraulics. We Manufacture. H y d r a u l i c s. Eaton Directional Control Valves. h y d r a u l i c s. Models and 31930

and RD5000 or by the Utility section in the Series 20 valves. 7. The internal pilot pressure is used to initiate the spool shift when a solenoid is en

DOUBLE, P.O. CHECK VALVES (PRE-ENGINEERED BLOCKS)

6200 Series. Specifications. Fluid End Power End Models 6211, 6212, 6221, & 6222 Models 6241 & 6242 Part Material Part Material Part Material

P.C. Priority Flow Control Valve Series J02D3. General Description

VALVE AND PLUMBING KIT NEW HOLLAND 7310 LOADER NEW HOLLAND TRACTORS

Form No , 9 5, 6. Parts List for: X1A1 AIR DRIVEN WITH REMOTE CONTROL HYDRAULIC PUMP. Max. Capacity: 10,000 PSI

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve:

FULL RANGE PRESSURE COMPENSATING VARIABLE FLOW CONTROL

DENISON HYDRAULICS open loop pump controls series P140 A-mod, P260 B-mod service information

DMH085** Series will be available January 1, Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.

SV SOLENOID OPERATED

Catalog HY /US Flow Control Valves SERIES CAVITY DESCRIPTION FLOW PRESSURE LPM/GPM BAR/PSI

VALVE AND PLUMBING KIT 4211 LOADER CASE IH JX55, JX65, JX75,JX85, AND JX95 TRACKTORS NON-CAB

EP-2 Three-Piston Pump

Form No Parts List for: RWP55 RWP55-4 MODEL C HYDRAULIC PUMP AIR DRIVEN WITH REMOTE CONTROL GENERAL ASS'Y SIDE VIEW SECTION A-A

VIS 40 Series Brake Motors Parts and Repair Manual -004

Contents. Quality Hydraulic Components from the Webtec Range. Introduction. Hydraulic Flow Control Valves

Logic elements. Differential pressure sensing elements for applications up to 350 bar (5000 psi) and 400 L/min (100 USgpm)

ASSEMBLY MANUAL SMC 2491 LOADER VALVE AND PLUMBING KIT INSTRUCTIONS KUBOTA TRACTORS

8. Illustrated Parts Lists

Char-Lynn Power Steering. Parts Information. 110, 230, and 450 Series. July, 1999

Vickers. Overhaul Manual. Directional Controls. CMX Sectional Directional Valve -25 Design. CMX100 & CMX160 Hydraulic & Electrohydraulic Actuation

3 Inch & 4 Inch Fuel Operated Bypass Pressure Control Valves. Models & 64513

SR1A-A2. Functional Description HA /2012. Directly Operated Pressure Relief Valves. Replaces HA /2010. Screw-in cartridge design

Eaton Electronic Proportional (EP) Control for Medium Duty Piston Pumps

EN-0800 (Replaces ) Eaton. Medium Duty Piston Pump. Parts Information. Model Servo Controlled Piston Pump v-04

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800)

EFC. Electronically Adjustable Proportional Pressure Compensated Flow Control

U1 PUMP PARTS PRICE LIST

Hydraulic and Pneumatic In-line and Cartridge Insert Control Valves for any fluid or gas.

SERVICE MANUAL. PVR15-Manifold Series Pump. J Design Series INSTALLATION. Ordering Code PVR15 - _ RM - _ - - J

LogSplitterPlans.Com

STRAIGHT FITTING ORIFICE DISK MUFFLER MANIFOLD MOUNTING PLATE MULTI-FUNCTION IMPACT SEAL CYLINDER TUBE 1/4 BSPP ELBOW FITTING HEAD ASSEMBLY

Eaton Fixed Displacement HHD Motor and Variable ACA Pump

PARTS BOOK CATALOG IMPLEMENT ASSEMBLIES STANDARD BOOM 3PT HITCH MOUNT

LOGIC POPPET VALVES AND CARTRIDGE MANIFOLD SYSTEMS

Part Number: MODEL NUMBER: Rev. 7

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800)

GROUP 11 HYD. PUMPS & VALVES

Section 6.1. Implement Circuit - General System. General: Implement Control Valve:

Pressure Compensator Valves Series R5P (SAE Flange Mounted) General Description. Features

Models & Inch & 4 Inch Digital Inline Pressure Control Valves SM64504

DeZURIK DR 40B ROTARY DIAPHRAGM ACTUATOR

CONTROL FOCUSED TECHNOLOGY DRIVEN MODEL 5000 SECTIONAL VALVE 5000 VALVE SERIES

Electronic Proportional (EP) Control for Medium Duty Piston Pumps

Series PVP Variable Volume Piston Pumps

CAB TILT HYDRAULIC SYSTEM

Hydraulic Valve Division EZ Reference Guide. Catalog

VPP2-04. Functional Description HA /2003. Directly operated pressure relief valves. Replaces HA /2002

Variable displacement axial piston pump type V30D

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800)

Electronic Proportional (EP) Control for Heavy Duty Series 0/1 Piston Pumps Model 33 Model 39 Model 46. Model 54 Model 64 Model 76

DENISON HYDRAULICS Premier Series. open loop pump controls series P080. service information

Transcription:

R GRESEN Hydraulics Model V0 Sectional Body Directional Control Valve Service and Parts Manual Maximum Operating Pressure: Minimum Filtration Required: 00 PSI ( bar) 0 Micron The information in this Service Manual was current at the time of publication. This information is subject to change at any time without notice. Model V0 Service and Parts Manual No. Revision: 0-0-00 (Replaces: SC-0 ~ Revision /)

Table of Contents Section Seal Replacement and Section Seal Kits... Page Spool Seal Replacement and Spool Seal Kits... Page Model V0 Manual Work Section... Page Model V0 [SOL] and [EPC] Solenoid Work Sections... Page Model V0 [SOL] and [EPC] Solenoid Work Section with Handle... Page K- Spring-Return Spool Positioner Kit... Page CK-0 D Detented Spool Positioner Kit... Page R Detent - Spring Return Spool Positioner Kits... Page 0 CK- PA Pneumatic Spool Actuator Kit... Page Installation Instructions for CK- Pneumatic Actuators... Page K- Hydraulic Remote HR Spool Actuator Kit... Page K- Hydraulic Remote HR Spool Actuator Kit... Page K-0 Hydraulic Remote HRO Spool Actuator Kit... Page K- Hydraulic Remote HRO Spool Actuator Kit... Page On/Off [SOL] Solenoid Actuator Assembly... Page Proportional [EPC] Solenoid Actuator Assembly... Page On/Off [SOL-IH] Solenoid Actuator Assembly... Page Proportional [EPC-IH] Solenoid Actuator Assembly... Page 0 Solenoid Actuator (with Handle) Removal & Installation... Page On/Off Solenoid Cartridge Kits (K-CRT-SXXX)... Page Proportional Solenoid Cartridge Kits (K-CRT-EXXX)... Page -Way, -Position (Plugged) Solenoid Bonnet Conversion... Page Solenoid Bonnet Spool Travel Limiter/Override Kits... Page Solenoid Bonnet (with Handle) Spool Travel Limiter Kit... Page K- Compensator Plug Kit... Page Model RCPC Work Port Relief Cartridge... Page Standard & Heavy Duty Seal Retainer Kits... Page Handle Bracket and Spool Boot Kits... Page 0 Vertical and Horizontal Handle Kits... Page Service Product Warranty, April... Page The information in this Service Manual was current at the time of publication. This information is subject to change at any time without notice. Model V0 Service and Parts Manual (Catalog No. SC-0) Rev: 0--00

V0 Work Section Housing Identification Warning There is a visual similarity between Gresen s Model V0 Directional Control Valve closed center and open center work sections. Work sections for these two valve assemblies should NEVER be intermixed or interchanged without prior consultation with the factory. Intermixing a V0C, V0LS or V0PC closed center section with a V0P, V0T or V0S work section will convert the complete valve bank to closed center operation and in some cases, could render the valve assembly inoperable and cause damage to components in the hydraulic circuit. Inlet Cover Casting No. Location (Flow Control Inlet) (Standard Inlet) Mid-Inlet Casting No. Location (Split or Combined Flow) Work Section Casting No. Location 0 (V0P 'Parallel') (V0T 'Tandem') 0 (V0RP 'Parallel') 0 (V0RT 'Tandem) (V0S 'Series') (V0LO 'Lockout' (V0C 'Closed Center') (V0LS 'Load Sense) (V0PC 'Pressure Comp') Outlet Cover Casting No. Location (Top Outlet) 0 (End Outlet) PB OUT Utility Section Casting No. Location 0 (Internal or External Pilot) Unloader Section Casting No. Location (With or Without Pilot) Figure. Casting Identification Numbers Model V0 Service and Parts Manual (Catalog No. SC-0) Rev: 0--00

K-XX Assembly Stud Kits K- or K- Section Seal Kits (See Figure ) 0000 Nut ( Nuts per Kit) Assembly Stud ( Studs per Kit) Torque to - Ft Lbs [ - Nm] (This is a dry torque spec - Reduce torque by Ft Lbs [ Nm] for oiled tie bolts) Figure. K-XX Stud Kit Components Kit No. and Description Number of Mid Sections Using: Tie Bolts and Nut Part Numbers Part Number Kit No. No. 0 Outlet No. Outlet Bolt No. () per Kit Nut No. () per Kit 000 000 000 000 00 00 00 00 00 00 00 K-0 K-0 K-0 K-0 K-0 K-0 K-0 K- K- K- K- One Section Two Sections Three Sections Four Sections Five Sections Six Sections Seven Sections Eight Sections Nine Sections Ten Sections Eleven Sections ----- One Section Two Sections Three Sections Four Sections Five Sections Six Sections Seven Sections Eight Sections Nine Sections Ten Sections 00 00 000 00000 00000 00000 00000 00000 00000 00000 0000 Notes: When using the Right End Cover, add one section to assure proper stud length. 000 000 000 000 000 000 000 000 000 000 000 Torque Specifications Replace the stud nuts and torque evenly to - Ft Lbs [ - Nm]. This is a dry stud torque spec. Reduce torque spec to - 0 Ft Lbs [ - Nm] for oily studs. CAUTION If the stud nuts are not tightened to the proper torque, valve spools may bind or stick, or cause O- Ring seals to extrude. Model V0 Service and Parts Manual (Catalog No. SC-0) Rev: 0--00

Section Seal Identificaton and Section Seal Kits Section Seal Changes As of April,, the section seals for the V0 changed. The new versions have larger cross section (the old was.00, the new is.0) and different configurations for open center and closed center sections. It is important to note that the seal kits include all O-Rings (new and old), therefore there will be some left unused. WARNING Do not pre-lube the O-Ring section seals prior to installation. Make sure that the O-Rings and valve counterbores are dry. Compression of lubricants can distort the valve body causing spool bind. (Prior To April, ) All Work Sections, Mid-Inlets, Utility Sections and Outlet Covers (After April, ) Open Center Work Sections (After April, ) Closed Center Work Sections, Mid-Inlets, Utility Sections and Outlet Covers Figure. Section Seal Identification Refer To The Warning Prior To Installing Section Seals Section Seal Kits 0000 000 000 000 000 00 00 00 K- Open Center Section Seal Kit (Includes all Seals Listed Below) K- Load Sense Section Seal Kit (Includes all Seals Listed Below) O-Ring Section Seal (Serviced in K- & K- Seal Kits) O-Ring Section Seal (Serviced in K- & K- Seal Kits) O-Ring Section Seal (Serviced in K- & K- Seal Kits) O-Ring Section Seal (Serviced in K- & K- Seal Kits) O-Ring Section Seal (Serviced in K- & K- Seal Kits) O-Ring Section Seal (Serviced in K- & K- Seal Kits) K- and K- Section Seal Kits include the same seal part numbers. The quantities of seals in each kit are different. Model V0 Service and Parts Manual (Catalog No. SC-0) Rev: 0--00

Spool Seal Replacement and Spool Seal Kits Positioner End Handle End 0 Spool Chamfer Figure. Spool Seal Removal Warning: DO NOT hold the spool with a pliers or wrench. This will destroy the finish. Spool Seal Removal These instructions apply to valves which have been removed from machines. If room permits rebuilding on the machine, first disconnect any lines which could hold pressure or supply oil into the valve assembly. It is recommended to drain the valve prior to rebuilding. For clarification, the control handle side of the valve is considered the front side. The seal retainer plate (Item ) is the larger round plate with a hole in the center and two half round notches opposite each other on the outer edge.. Remove the bonnet and spool positioner hardware (Item ) from the back of the work section. Keep parts in order of disassembly. If the work section does not include a handle assembly, prevent the spool from turning or moving by inserting a screw driver through clevis slot, or running a rod through the pin hole and using it as a handle.. Remove the complete handle, handle bracket or seal retainer hardware (Item ) from the front of the work section.. Push the spool into the housing from the front of the valve until the front seal is exposed. Since the spool seals can be replaced externally, it is not necessary to remove the spool from the housing. Remove the retainer plate washers (Item ), back-up washers (Item ), and spool seals (Item ).. Remove the back seal in the same manner. Note: The back spool seal is located inside the detent sleeve in V0 Float sections. Refer to Figures 0 & for parts illustration for float positioner.. Remove the bonnet and spool positioner assembly parts (Item ) from the back of the work section. Keep in order of disassembly. Model V0 Service and Parts Manual (Catalog No. SC-0) Rev: 0--00

Spool Seal Replacement and Spool Seal Kits Positioner End Handle End 0 Spool Chamfer Figure. Spool Seal Installation Spool Seal Kits 000 00 00 000 000 00000 Spool Seal Installation Front Spool Seal Installation (O-Ring Spool Seal) K-0 Standard Buna-N Spool Seal Kit (Includes Items and Only) K- Spool Positioner Assembly (See Figures thru for Positioner Options) K-0 Seal Retainer Assembly (See Figures thru for Handle End Options) Seal Retainer Plate Back-Up Washer Buna-N Spool Seal (Serviced in K-0 Spool Seal Kit). Push the spool into the housing from the front side of the valve until the chamfer on the spool is flush with the bottom of the seal gland. Install O-Ring spool seal into the seal gland.. Place the new back-up washer (Item ) over the spool and up against the spool seal.. Place the seal retainer plate (Item ) over the spool and up against the back-up washer. Push firmly into place.. Hold the seal retainer plate against the valve body and push the spool from the back side thru the seal approximately ¼ inch.. Install O-Ring spool seal and backup washer into the seal gland in the same manner as in the front side.. Reassemble (in reverse order) all hardware disassembled in Steps &, Spool Seal Removal. Back Seal Installation (Float Work Sections Only) (Refer to Figures 0 & for Float Positioner illustration). With the float positioner disassembled from the spool, slip the retainer sleeve over the spool into the counterbore in the valve housing. Slide the spool seal onto the spool and against the retainer sleeve.. Install the face seal O-Ring into the spotface in the end of the detent sleeve. Slip the detent sleeve onto the Back Seal Installation (Standard - and -Way Sections) spool, over the spool seal, and up against the valve housing.. Push the spool into the housing from the back side until the end of the spool is flush with the valve back. Reassemble (in reverse order) all hardware face, not the bottom of the seal gland. If the spool is disassembled in Steps &, Spool Seal Removal. pushed in too far, the metering notches and/or spool land may be moved into the seal area on the front end of the valve. If this happens, DO NOT push the spool back into the valve. Disassemble the seal assembly and carefully remove the seal from the spool. Reassemble per Steps thru. Model V0 Service and Parts Manual (Catalog No. SC-0) Rev: 0--00

Model V0 Directional Control Valve Typical Main Assembly 0 Figure. Model V0 Directional Control Valve Typical Main Assembly Ref No. Description Refer To Page(s): 0 Assembly Bolts and Nuts Inlet Cover Housing Main Relief Cartridge Port Plugs Section Seals Mid Sections/Mid-Inlets/Utility Sections Spool Positioners Handles Work Port Relief Cartridge Outlet Cover Housing Outlet Cover Conversion Options Model V0 Service and Parts Manual (Catalog No. SC-0) Rev: 0--00

Special Note Regarding Back-Up Rings Back-Up Rings in Used Seal Kits Many of the plugs and cartridges used in the Gresen product line utilize back-up rings. Therefore, many of the seal kits in this Service Manual include back-up rings, some of which are continuous back-up rings. (Continuous) Back-Up Rings Since the continuous back-up rings are installed at the factory using a special sizing tool, only replace this back-up ring if it has been damaged. Preparing the Back-Up Ring for Installation If the continuous back-up ring should need replacing, follow these simple procedures.. Using a single edge razor blade, carefully cut through the back-up ring in an angle as shown in the drawing. Carefully make one cut thru Back-Up Ring at approximately 0 degree angle as shown here. Caution: Make only one diagonal cut thru the back-up ring. Do not separate the ring into two pieces.. Slip the back-up ring over the cartridge and into place. Model V0 Service and Parts Manual (Catalog No. SC-0) Rev: 0--00

No. Inlet Cover No. Inlet Cover No. Inlet Covers offers top and end inlet and outlet ports. All unused ports must be plugged. If a gauge port is required, a port plug may be drilled and tapped for a /" NPTF or SAE and installed in the unused inlet port. Port Plugs and the main relief cartridge are the serviceable components located in the inlet cover. Main Relief Cartridge Options No. Inlet Covers are machined to accept the inlet (main) relief valve cartridge. Main relief cartridges are available in the following options: Model WH Differential Area Relief Available in internal shim adjustable, externally adjustable, and dual pressure versions. Model RP Pilot Operated Relief - Available in externally adjustable, tamper resistant and dual pressure versions. No Relief Plug Must be used when no main relief is required. Figure. No. 00xxx Inlet Cover Assembly Using 0xxx Inlet Cover Housing 0xxx 0xxx 0xxx xxx 00xxx 00xxx 00xxx 00 0000 Inlet Cover Housing WH Relief Cartridge (See Figure ) WHA Relief Cartridge (See Figure 0) WH Dual Pressure Relief Cartridge (See Figure ) RPA Relief Cartridge (See Figure ) RPN Relief Cartridge (See Figure ) RP Dual Pressure Relief Cartridge (See Figure ) CK- No Relief Cavity Plug (See Figure ) SAE Port Plug (Plug Selection Determined by Inlet Porting Refer to Page 0 for a listing of available port plugs. No. 0 Inlet Cover Housing are available in many porting configurations. Contact the Gresen factory for help in identifying No. 0 housing part numbers. Model V0 Service and Parts Manual (Catalog No. SC-0) 0 Rev: 0--00 A/R

No. Inlet Cover with Flow Control No. Inlet Cover This inlet cover offers top and end inlet and end outlet ports. All unused ports must be plugged. Port plugs, inlet relief cartridge, and the flow control are the serviceable components located in the inlet cover. Inlet Flow Control Option This cover is equipped with an adjustable flow control assembly. Installation of the conversion plug in the excess flow port will permit use of the excess flow for power beyond applications. Oil will only be directed out this port when a work section is actuated. With all sections in neutral, oil is directed thru open center and back to tank. Main Relief Cartridge Options No. inlet covers are machined to accept the inlet (main) relief valve cartridge. Main relief cartridges are available in the following options: Model WH Differential Area Relief Available in internal shim adjustable, externally adjustable, and dual pressure versions. Model RP Pilot Operated Relief - Available in externally adjustable, tamper resistant and dual pressure versions. No Relief Plug Must be used when no main relief is required. Internal Conversion Plug - Must be installed to use the Excess Flow (Power Beyond) option Figure. No. 0xxx Inlet Cover Assembly Using 0xxx Inlet Cover Housing 0xxx 000xxx 0xxx 0xxx xxx 00xxx 00xxx 00xxx 00 0000 0000 Inlet Cover Housing Flow Control Assembly (See Figure ) WH Relief Cartridge (See Figure ) WHA Relief Cartridge (See Figure 0) WH-Dual Pressure Relief Cartridge (See Figure ) RPA Relief Cartridge (See Figure ) RPN Relief Cartridge (See Figure ) RP Dual Pressure Relief Cartridge (See Figure ) CK- No Relief Cavity Plug (See Figure ) SAE Port Plug (Plug Selection Determined by Inlet Porting Refer to Page 0 for a listing of available port plugs. Excess Flow Conversion Plug (/ NPTF) No. 0 Inlet Cover Housing are available in many porting configurations. Contact the Gresen factory for help in identifying No. 0 housing part numbers. A/R Model V0 Service and Parts Manual (Catalog No. SC-0) Rev: 0--00

Model WH and WHA (Differential Poppet) Main Relief Cartridges Torque to: 0 Ft Lbs ( Nm) Torque to: Ft Lbs ( Nm) Figure. Model WH and WHA (Differential Poppet) Main Relief Cartridges (Model WH Shown) 0xxx 0xxx 000 00 000 0000 000 000 000 0000 0000 0000 000 000 0000 0000 000 00 0000 0000 Model WH Relief Cartridge, Complete (Specify Pressure Setting When Ordering) Model WHA Relief Cartridge, Complete (Specify Pressure Setting When Ordering) K-00 WH Relief Seal Kit (Includes Items,, & ) K-00 Relief Poppet Service Kit (Contains Item - Poppet and Seal Assembly) O-Ring Seal (Serviced in K-00 Relief Seal Kit) Back-Up Ring (Serviced in K-00 Relief Seal Kit) O-Ring Seal (Serviced in K-00 Relief Seal Kit) WH Relief Body Poppet Shim (.00 inch [,0 mm] thick) Shim (.00 inch [0, mm] thick) Shim (.00 inch [0, mm] thick) Spring (00 - PSI [ - bar] Pressure Range) Spring (0 - PSI [ - bar] Pressure Range) Spring (0 - PSI [ - 0 bar] Pressure Range) Spring (000 - PSI [ - bar] Pressure Range) Spring (00 - PSI [ - 0 bar] Pressure Range) Spring (000-00 PSI [0 - bar] Pressure Range) O-Ring Seal (Serviced in K-00 Relief Seal Kit) Relief Cap A/R A/R A/R Buna-N seals are standard for all Gresen valve assemblies. For Viton seals, contact the Gresen factory in Minneapolis. Model WHA Relief Cartridge replaces Items & with the CK-00 External Adjustment Kit shown in Figure 0. Do not attempt to change shims or springs in these reliefs unless you have the capability to test for proper pressure setting. Without the capability to test you may exceed the maximum pressure rating of the product or draw the relief spring solid, which in turn means there is no relief (NR). Continuous Back-Up Rings are installed at the factory using special sizing tools. It is Not necessary to replace the original Back-Up Rings unless they have been damaged. See Page for Back-Up Ring Preparation and Installation procedures. Model V0 Service and Parts Manual (Catalog No. SC-0) Rev: 0--00

CK-00 (K-WH-A) External Adjustment Kit Torque Relief Cartridge To: 0 Ft Lbs [ Nm] Model 'WHA' Shown Here Torque to: Ft Lbs (0 Nm) Torque to: 0 Ft Lbs ( Nm) Relief Valve Cartridge With Relief Cap Removed - Refer To Individual Relief Cartridges For Servicing Information. Figure 0. CK-00 (K-WH-A) External Adjustment Kit Note: This Kit May Be Used On Model WH (Figure ), RC (Figure ), RCS (Figure ), RCPC (Figure 0) and CRA (Figure ) Relief Cartridges 000 000 00 000 0000 000 000 00000 000 CK-00 External Adjustment Kit (Contains All Items listed here) K-0 Adjustment Kit Seal Kit (Contains Items and Only) Piston O-Ring Seal O-Ring Seal Adjustment Adapter Adjustment Stem Jam Nut Acorn Nut Buna-N seals are standard for all Gresen valve assemblies. Do not attempt to adjust these reliefs unless you have the capability to test the reliefs for proper pressure setting. Without the capability to test you may exceed the maximum pressure rating of the product or draw the relief spring solid, which in turn means there is no relief (NR). Model V0 Service and Parts Manual (Catalog No. SC-0) Rev: 0--00

K-00 Dual Pressure Relief Head Kit Torque Relief Cartridge To: 0 Ft Lbs [ Nm] Model WH-S Dual Pressure Relief Cartridge Shown Here Torque to: 0 Ft Lbs ( Nm) Torque to: Ft Lbs (0 Nm) Adjustment Screw. Turn full in to shim-set high pressure.. Back off to set low pressure. Remote Pilot Port is SAE Figure. K-00 Dual Pressure Relief Head Kit Relief Valve Cartridge With Relief Cap Removed - Refer To Individual Relief Cartridges For Servicing Information. Note: This Kit May Be Used On Model WH (Figure ), RC (Figure ), RCS (Figure ), RCPC (Figure 0) and CRA (Figure ) Relief Cartridges 00 00 0000 000 00 0000 000 000 000 000 000 K-00 Dual Pressure Relief Head Kit (Contains All Items listed here) K-0 Relief Head Seal Kit (Contains Items,,, & ) O-Ring Seal Body Back Up Ring O-Ring Seal Piston O-Ring Seal Back Up Ring Adjustment Screw Hex Jam Nut Buna-N seals are standard for all Gresen valve assemblies. Do not attempt to adjust these reliefs unless you have the capability to test the reliefs for proper pressure setting. Without the capability to read pressure, you may exceed the maximum pressure rating of the product or compress the relief spring solid, which in turn means there is no relief (NR). Continuous Back-Up Rings are installed at the factory using special sizing tools. It is Not necessary to replace the original Back-Up Rings unless they have been damaged. See Page for Back-Up Ring Preparation and Installation procedures. Model V0 Service and Parts Manual (Catalog No. SC-0) Rev: 0--00

Model RP Main Relief Cartridges Torque Relief Cartridge To: 0 Ft Lbs [ Nm] RP-A RP-N Figure. Model RP (Pilot-Operated) Main Relief Cartridges NOTE Due to close tolerances on working parts, the RP Pilot-Operated Relief Valve is not field serviceable. If service other than external seal replacement is required, replace the complete cartridge. 0000 000 0000 000 000 000 0000 000 0000 RP-A Cartridge, Adjustable from 000-00 PSI [ 0 bar] RP-A-LP Cartridge, Adjustable from 00 - PSI [ bar] RP-N Cartridge, Tamper Resistant, Preset 000 00 PSI [ 0 bar] RP-N-LP Cartridge, Tamper Resistant, Preset 00 PSI [ bar] K-0 Plug Seal Kit (Contains Items thru Only) See Note Below O-Ring Seal Back Up Ring O-Ring Seal Tamper Resistant Cap (Installed at the factory on RP-N Versions Only) Buna-N seals are standard for all Gresen valve assemblies. Specify relief valve pressure setting when ordering. Do NOT attempt to adjust these relief valves unless you have the capability to test the reliefs for proper pressure setting. Without the capability to test you may exceed the maximum pressure rating of the product or draw the relief spring solid, which in turn means there is no relief (NR). RP-N and RP-N-LP Cartridges are preset at the factory and then the Tamper Resistant Cap is installed. Continuous Back-Up Rings are installed at the factory using special sizing tools. It is Not necessary to replace the original Back-Up Rings unless they have been damaged. See Page for Back-Up Ring Preparation and Installation procedures. Model V0 Service and Parts Manual (Catalog No. SC-0) Rev: 0--00

Model RP - Dual Pressure Main Relief Cartridges Torque Relief Cartridge To: 0 Ft Lbs [ Nm] RP-A Dual Pressure Relief T P Remote Pilot Source SAE Pilot Port For Remote Pilot Source (Minimum of 00 PSI [ bar] Required) High Pressure Adjustment Locknut Low Pressure Adjustment Locknut Figure. Model RP Dual Pressure Main Relief Cartridges NOTE Due to close tolerances on working parts, the RP Dual Pressure Pilot-Operated Relief Valve is not field serviceable. If service other than external seal replacement is required, replace the complete cartridge. 0000 000 000 0000 000 0000 RP-A-DP Cartridge, Dual Pressures, Adjustable from 000-00 PSI [ 0 bar] K-0 Plug Seal Kit (Contains Items thru Only) See Note Below O-Ring Seal Back Up Ring O-Ring Seal Tamper Resistant Cap (Installed at the factory on RP-N Versions Only) Buna-N seals are standard for all Gresen valve assemblies. Specify relief valve pressure setting when ordering. Do NOT attempt to adjust these relief valves unless you have the capability to test the reliefs for proper pressure setting. Without the capability to test you may exceed the maximum pressure rating of the product or draw the relief spring solid, which in turn means there is no relief (NR). Continuous Back-Up Rings are installed at the factory using special sizing tools. It is Not necessary to replace the original Back-Up Rings unless they have been damaged. See Page for Back-Up Ring Preparation and Installation procedures. Model V0 Service and Parts Manual (Catalog No. SC-0) Rev: 0--00

CK- Main Relief NR Cavity Plug Torque Relief Cavity Plug To: 0 Ft Lbs [ Nm] Inlet Tank Figure. CK- Main Relief NR Cavity Plug 00 000 000 0000 000 0000 CK- No Relief NR Plug Kit (Contains All Items Listed Below) K-0 Plug Seal Kit (Contains Items thru Only) O-Ring Seal (Serviced in K-0 Plug Seal Kit) Back-Up Ring (Serviced in K-0 Plug Seal Kit) O-Ring Seal (Serviced in K-0 Plug Seal Kit) Relief Cavity Plug Buna-N seals are standard for all Gresen valve assemblies. For Viton seals, contact the Gresen factory in Minneapolis. Continuous Back-Up Rings are installed at the factory using special sizing tools. It is Not necessary to replace the original Back-Up Rings unless they have been damaged. See Page for Back-Up Ring Preparation and Installation procedures. Model V0 Service and Parts Manual (Catalog No. SC-0) Rev: 0--00

Inlet Cover Flow Control Used In 0xxx Inlet Assemblies Torque to: Ft Lbs ( Nm) 0 Figure. Inlet Cover Flow Control 0 00 00 000 0000 00 000 00 0000 0000 000 0000 0000 0000 0000 000 00000 00000 00000 000 000 K-0 ( to GPM - to 0 lpm) Flow Control Kit (Contains Item 0 thru Only) K-0 ( to GPM - 0 to lpm) Flow Control Kit (Contains Item 0 thru Only) K- ( to GPM - to lpm) Flow Control Kit (Contains Item 0 thru Only) K-0 Flow Control Seal Kit (Contains Items,,, & Only) K-0 Flow Control Adjustment Kit (Contains Items thru Only) Knob Hex Head Screw Lock Washer Cap O-Ring Seal (Serviced in K-0 Seal Kit) Flow Adjuster (Standard) Flow Adjuster (Optional - inch [ mm] stem) Back-Up Ring (Serviced in K-0 Seal Kit) O-Ring Seal (Serviced in K-0 Seal Kit) Spring Flow Control Assembly ( to GPM [ to 0 lpm]) (Serviced in K-0 F/C Kit) Flow Control Assembly ( - GPM [ - lpm]) (Serviced in K- F/C Kit) Flow Control Assembly ( to GPM [0 to lpm]) (Serviced in K-0 F/C Kit) O-Ring Seal (Serviced in K-0 Seal Kit) Back-Up Ring (Serviced in K-0 Seal Kit) Buna-N seals are standard for all Gresen valve assemblies. For Viton seals, contact the Gresen factory in Minneapolis. Continuous Back-Up Rings are installed at the factory using special sizing tools. It is Not necessary to replace the original Back-Up Rings unless they have been damaged. See Page for Back-Up Ring Preparation and Installation procedures. Model V0 Service and Parts Manual (Catalog No. SC-0) Rev: 0--00

No. Outlet Cover No. Outlet Cover This cover offers top, end or bottom outlet ports in addition to a top power beyond port. All unused outlet ports must be plugged. Caution: No. Outlet Cover may only be used in open center and closed center (high pressure standby) systems. They may not be used with V0LS Work Sections. An internal plug (00) is available for conversion to closed center or power beyond. Port Plug Installed in PB port will convert the valve to Closed Center when the Internal Conversion Plug is installed. PB OUT Internal Conversion Plug (Must be installed for conversion to Power Beyond or Closed Center) Figure. No. Outlet Cover 0000 0xxx 00 0000 00 00 K- Section Seal Kit (Includes Ref No s. & ) Outlet Cover Housing Internal Conversion Plug (SAE Socket Head) SAE Port Plug (Plug Selection Determined by Inlet Porting Refer to Page listing of available port plugs. O-Ring Seal (Serviced in K- Section Seal Kit) O-Ring Seal (Serviced in K- Section Seal Kit) Buna-N seals are standard for all Gresen valve assemblies. For Viton seals, contact the Gresen factory. No. 0 Outlet Cover Housing are available in many porting configurations. Contact the Gresen factory for help in identifying No. 0 housing part numbers. for a A/R Model V0 Service and Parts Manual (Catalog No. SC-0) Rev: 0--00

No. 0 Outlet Cover With Conversion Port Non Load Sense No. 0 Outlet Cover This outlet cover offers an end outlet port (port on left). A second (conversion) port is located in the center of the outlet cover. This port accepts the closed center or power beyond conversion plugs. Closed Center Conversion Provides a Closed Center system by plugging the open center flow passage. This is normally used with a variable displacement pump. A closed center plug is installed in the option port in the outlet cover. Power Beyond Conversion Provides for proper hook-up of an additional valve downstream. The Power Beyond Sleeve prevents subjecting the exhaust core to back pressure. A power beyond sleeve is installed in the option port in the outlet cover to convert to power beyond. Caution: Never attempt to plug the power beyond sleeve, as this will convert the valve to Closed Center. Conversion Port (Accepts Power Beyond Sleeves and Closed Center Conversion Plugs) Figure. No. 0 (Open Center) Outlet Cover Assembly 0000 00xxx 000 00 00 00 00 00 00 00 00 K- Section Seal Kit (Includes Ref No s. & Only) Outlet Cover Housing K-0 Conversion Plug (See Figure ) CK-0 (Optional) Closed Center Plug (See Figure ) CK-0 (Optional) / NPT Power Beyond Sleeve (See Figure ) CK-0 (Optional) SAE Power Beyond Sleeve (See Figure ) CK-0 (Optional) SAE 0 Power Beyond Sleeve (See Figure ) K- (Optional) SAE Power Beyond Sleeve (See Figure ) K-00 (Optional) SAE Male Power Beyond Sleeve (See Figure ) O-Ring Seal (Order K- Section Seal Kit) O-Ring Seal (Order K- Section Seal Kit) Buna-N seals are standard for all Gresen valve assemblies. For Viton seals, contact the Gresen factory. No. 00 Outlet Cover Housing are available in many porting configurations. Contact the Gresen factory for help in identifying No. 00 housing part numbers. Model V0 Service and Parts Manual (Catalog No. SC-0) 0 Rev: 0--00

No. 0 Outlet Cover With Solenoid Cartridge Non Load Sense No. 0 Outlet Cover This outlet cover offers an end outlet port (port on left). A second (conversion) port is located in the center of the outlet cover. This port accepts the closed center or power beyond conversion plugs. Power Beyond Conversion A power beyond sleeve is installed in the option port in the outlet cover to convert to power beyond. V.D. C. Figure. No. 0 Outlet Cover With Solenoid Cartridge 0000 00xxx 00 00 000 00 00 K- Section Seal Kit (Includes Ref No s. & Only) Outlet Cover Housing CK- VDC Build Up Cartridge - See Figure xx CK- VDC Build Up Cartridge - See Figure xx CK- Mechanical Build Up Cartridge Kit See Figure xx O-Ring Seal (Order K- Section Seal Kit) O-Ring Seal (Order K- Section Seal Kit) Buna-N seals are standard for all Gresen valve assemblies. For Viton seals, contact the Gresen factory. No. 00 Outlet Cover Housing are available in many porting configurations. Contact the Gresen factory for help in identifying No. 00 housing part numbers. Model V0 Service and Parts Manual (Catalog No. SC-0) Rev: 0--00

No. 0 V0LS Outlet Cover (No Load Sense Bleed-Down Plug) No. 0 Outlet Cover The outlet cover offers top and end outlet ports. unused outlet port must be plugged. The Solenoid Pilot Seal Counterbores Figure. No. 0 V0LS Outlet Cover Assembly 000 00xxx 00000 00 00 00 K- Section Seal Kit (Includes Ref No s. thru ) Outlet Cover Housing / - NPTF Port Plug O-Ring Seal (Serviced in K- Section Seal Kit) O-Ring Seal (Serviced in K- Section Seal Kit) O-Ring Seal (Serviced in K- Section Seal Kit) Buna-N seals are standard for all Gresen valve assemblies. For Viton seals, contact the Gresen factory. No. 00 Outlet Cover Housing are available in many porting configurations. Contact the Gresen factory for help in identifying No. 00 housing part numbers. A/R Model V0 Service and Parts Manual (Catalog No. SC-0) Rev: 0--00

No. 0LS Outlet Cover (With Load Sense Bleed-Down Plug) No. 0LS Outlet Cover The outlet cover offers top and end outlet ports. unused outlet port must be plugged. The Port plugs and bleed-down cartridges are field serviceable components located in the outlet cover. Optional Outlet Plugs Bleed-Down Plug Solenoid Pilot Seal Counterbores Figure 0. No. 0LS Outlet Cover Assembly 000 00xxx 000 00 00 00 K- Section Seal Kit (Includes Ref No s. thru ) Outlet Cover Housing K- Bleed-Down Cartridge Kit (See Figure ) O-Ring Seal (Serviced in K- Section Seal Kit) O-Ring Seal (Serviced in K- Section Seal Kit) O-Ring Seal (Serviced in K- Section Seal Kit) Buna-N seals are standard for all Gresen valve assemblies. For Viton seals, contact the Gresen factory. No. 00 Outlet Cover Housing are available in many porting configurations. Contact the Gresen factory for help in identifying No. 00 housing part numbers. Model V0 Service and Parts Manual (Catalog No. SC-0) Rev: 0--00

Conversion Port Option Plugs for 0 Outlet Cover K-0 Conversion Plug Kit CK-0 Closed Center Plug Kit Conversion Port Location Note: Not All 00 Housings Have The Conversion Port Machined CK-0 CK-0 CK-0 K- Power Beyond Sleeve Kits K-00 Power Beyond Sleeve Kit Figure. Conversion Plugs for 0 Outlet Cover (Open Center) 000 00 00 00 00 00 00 000 000 0000 000 000 000 000 000 0000 0000 000 K-0 Conversion Plug Kit - Supplied as Standard (Includes Ref No s. & ) CK-0 Closed Center Plug Kit (Includes Ref No s.,, & ) CK-0 / NPT Power Beyond Sleeve Kit (Includes Ref No s. thru ) CK-0 SAE Power Beyond Sleeve Kit (Includes Ref No s. thru ) CK-0 SAE 0 Power Beyond Sleeve Kit (Includes Ref No s. thru ) K- SAE Power Beyond Sleeve Kit (Includes Ref No s. thru ) K-00 SAE Power Beyond Sleeve Kit (Includes Ref No s. thru ) K-0 Plug Seal Kit (Includes Ref No s. thru Only) Conversion Plug Closed Center Plug Power Beyond Sleeve with / NPT Port Power Beyond Sleeve with SAE Port Power Beyond Sleeve with SAE 0 Port Power Beyond Sleeve with SAE Port Power Beyond Sleeve with SAE Male Connection O-Ring Seal (Serviced in K-0 Plug Seal Kit) Back-Up Ring (Serviced in K-0 Plug Seal Kit) O-Ring Seal (Serviced in K-0 Plug Seal Kit) Buna-N seals are standard for all Gresen valve assemblies. For Viton seals, contact the Gresen factory. Continuous Back-Up Rings are installed at the factory using special sizing tools. It is Not necessary to replace the original Back-Up Rings unless they have been damaged. See Page for Back-Up Ring Preparation and Installation procedures. Model V0 Service and Parts Manual (Catalog No. SC-0) Rev: 0--00

Load Sense Bleed-Down Plug for 0LS Outlet Cover K- Bleed Down Cartridge Kit Cleaning Instructions????? Required per LS System Load Sense Bleed-Down Plug Clean Threads and Apply Loctite Ref. No. Thread Locking Compound to Ref No. prior to installation Figure. Load Sense Bleed-Down Plug for 0LS Outlet Cover 000 000 00 0000 00 000 00 00 000 K-0 Bleed-Down Cartridge Kit (Includes All Ref No s Listed Below) K- Cartridge Seal Kit (Includes Ref No s. and Only) Bleed-Down Plug O-Ring Seal (Serviced in K- Cartridge Seal Kit).0 Orifice Screw (Standard) O-Ring Seal (Serviced in K- Cartridge Seal Kit) Filter Screen Back-Up Washer Locking Screw Buna-N seals are standard for all Gresen valve assemblies. For Viton seals, contact the Gresen factory. Optional Orifice Screws are available from the Gresen factory. Available bleed hole diameters sizes are:.00,.00 &.00. The Load Sense Bleed-Down Plug can be converted to a no-bleed assembly in the field by replacing the Orifice Screw with a solid screw Gresen Part Number 00. Install plug flush or slightly below surface. Model V0 Service and Parts Manual (Catalog No. SC-0) Rev: 0--00

-Way, -Position Parallel & Tandem Work Sections Tandem B Parallel B T OC P T OC P Figure. -Way, -Position Parallel & Tandem Work Sections (Parallel Housing Shown Here) 0000 00xxx 0xxx 0xxx 0xxx 0000 00 00 000 00 00 000 0000 0000 K-0 Work Section Service Kit - Standard Buna-N O-Rings V0P Parallel Work Section Housing (Not Serviceable) V0RP Parallel Work Section Housing (Not Serviceable) V0T Tandem Work Section Housing (Not Serviceable) V0RT Tandem Work Section Housing (Not Serviceable) -Way Spool (Not Serviceable) K- (V0P and V0T) Spring-Return Spool Positioner Kit (See Figure ) K-0 (V0RP and V0RT) Spring-Return Spool Positioner Kit (See Figure ) -Way Conversion Plug K-00 Load Check Plug Assembly (See Figures thru for Options) K-0 Seal Retainer Kit (See Figures thru for Handle End Options) K-0 Spool Seal Assembly (Serviced in Spool Seal Kits - See Figure ) SAE 0 Port Plug (Plug Selection Determined By Port Size) ½ - NPT Port Plug Work Section Service Kits include all the seals and back-up rings required to service one V0 work section. Contact the Gresen factory in Minneapolis for porting options. The work section housing and spool are matched and are not sold separately. Warning: If you are using the free flow (F) spool configuration in a cylinder lift application, it must be used in conjunction with a load holding device. A load holding device will prevent the load from free falling when the spool is in the neutral position. A free falling load could cause serious bodily injury or property damage if the holding device is not installed. Manual Positioners and Actuators will NOT work on Solenoid Work Section housings. Do not install the load check poppet and spring on the same side that the conversion plug (Item ) is installed. Model V0 Service and Parts Manual (Catalog No. SC-0) Rev: 0--00

-Way, -Position Parallel & Tandem Work Sections B Tandem A Parallel B A T OC P T OC P Figure. -Way, -Position Parallel & Tandem Work Sections (Tandem Housing Shown Here) 0000 00xxx 0xxx 0xxx 0xxx 0000 0000 00 00 00 00 000 K-0 Work Section Service Kit - Standard Buna-N O-Rings V0P Parallel Work Section Housing (Not Serviceable) V0RP Parallel Work Section Housing (Not Serviceable) V0T Tandem Work Section Housing (Not Serviceable) V0RT Tandem Work Section Housing (Not Serviceable) -Way Spool (Not Serviceable) -Way Free Flow Spool (Not Serviceable) K- (V0P and V0T) Spring-Return Spool Positioner Kit (See Figure ) K-0 (V0RP and V0RT) Spring-Return Spool Positioner Kit (See Figure ) K-00 Load Check Plug Assembly (See Figures thru for Options) K-0 Seal Retainer Kit (See Figures thru for Handle End Options) K-0 Spool Seal Assembly (Serviced in Spool Seal Kits - See Figure ) Work Section Service Kits include all the seals and back-up rings required to service one V0 work section. Contact the Gresen factory in Minneapolis for porting options. The work section housing and spool are matched and are not sold separately. Warning: If you are using the free flow (F) spool configuration in a cylinder lift application, it must be used in conjunction with a load holding device. A load holding device will prevent the load from free falling when the spool is in the neutral position. A free falling load could cause serious bodily injury or property damage if the holding device is not installed. Manual Positioners and Actuators will NOT work on Solenoid Work Section housings. Model V0 Service and Parts Manual (Catalog No. SC-0) Rev: 0--00

-Way, -Position Float Parallel & Tandem Work Sections Tandem B A Parallel B A T OC P T OC P Figure. -Way, -Position Float Parallel & Tandem Work Sections (Parallel Housing Shown Here) 0000 00xxx 0xxx 0xxx 0xxx 0000 00 00 00 000 K-0 Float Work Section Service Kit - Standard Buna-N O-Rings V0P Parallel Work Section Housing (Not Serviceable) V0RP Parallel Work Section Housing (Not Serviceable) V0T Tandem Work Section Housing (Not Serviceable) V0RT Tandem Work Section Housing (Not Serviceable) -Way Float Spool (Not Serviceable) K- -Position Float Spool Positioner Kit (See Figure ) K-00 Load Check Plug Assembly (See Figures thru for Options) K-0 Seal Retainer Kit (See Figures thru for Handle End Options) K-0 Spool Seal Assembly (Serviced in Spool Seal Kits - See Figure ) Work Section Service Kits include all the seals and back-up rings required to service one V0 work section. Contact the Gresen factory in Minneapolis for porting options. The work section housing and spool are matched and are not sold separately. -Position Spool Positioners and Actuators will NOT work on Float Work Sections. Model V0 Service and Parts Manual (Catalog No. SC-0) Rev: 0--00

-Way, -Position V0LO Lockout Work Section B A T OC P Figure. -Way, -Position V0LO Lockout Work Section 0000 xxx 000 00 00 000 00 00 000 K-0 Work Section Service Kit - Standard Buna-N O-Rings V0LO Lockout Work Section Housing (Not Serviceable) -Way Lockout Spool (Not Serviceable) K- (V0P and V0T) Spring-Return Spool Positioner Kit (See Figure ) K-0 (V0RP and V0RT) Spring-Return Spool Positioner Kit (See Figure ) K-0 Lockout Check Plug Assembly (See Figure ) Unlocking Piston K-0 Seal Retainer Kit (See Figures thru for Handle End Options) K-0 Spool Seal Assembly (Serviced in Spool Seal Kits - See Figure ) Work Section Service Kits include all the seals and back-up rings required to service one V0 work section. Contact the Gresen factory in Minneapolis for porting options. The work section housing and spool are matched and are not sold separately. Model V0 Service and Parts Manual (Catalog No. SC-0) Rev: 0--00

-Way, -Position Parallel & Tandem Work Sections with KO Tandem B A B Parallel A T P OC T OC P Figure. -Way, -Position Parallel & Tandem Work Sections with KO (Tandem Housing Shown Here) 0000 00xxx 0xxx 0xxx 0xxx 000 000 00 00 000 K-0 Work Section Service Kit - Standard Buna-N O-Rings V0P Parallel Work Section Housing (Not Serviceable) V0RP Parallel Work Section Housing (Not Serviceable) V0T Tandem Work Section Housing (Not Serviceable) V0RT Tandem Work Section Housing (Not Serviceable) -Way KO (Knockout) Spool (Not Serviceable) -Position KO Spool Positioner Kit (See Figure ) K-00 Load Check Plug Assembly (See Figures thru for Options) K-0 Seal Retainer Kit (See Figures thru for Handle End Options) K-0 Spool Seal Assembly (Serviced in Spool Seal Kits - See Figure ) Work Section Service Kits include all the seals and back-up rings required to service one V0 work section. Contact the Gresen factory in Minneapolis for porting options. The work section housing and spool are matched and are not sold separately. KO Knockout Spool Positioners will NOT work with standard spools. Model V0 Service and Parts Manual (Catalog No. SC-0) 0 Rev: 0--00

Model V0 Externally Piloted Solenoid Work Sections B A T OC P Figure. Model V0 Externally Piloted Solenoid Work Sections (Parallel -Way Section Shown) 0000 00xxx 0xxx 0xxx 0xxx 0000 0000 0000 00 000 00000 000 00 K-0 Work Section Service Kit - Standard Buna-N O-Rings V0P Parallel Work Section Housing (Not Serviceable) V0RP Parallel Work Section Housing (Not Serviceable) V0T Tandem Work Section Housing (Not Serviceable) V0RT Tandem Work Section Housing (Not Serviceable) -Way Spool (Not Serviceable) -Way Free Flow Spool (Not Serviceable) K- VDC Solenoid Actuator Kit (See Figure ) K-00 Load Check Plug Assembly (See Figures thru for Options) K-0 Spool Seal Assembly (Serviced in Spool Seal Kits - See Figure ) O-Ring Seal (Serviced in Spool Seal Kits Figure ) Back-Up Ring (Serviced in Spool Seal Kits Figure ) K-0 Seal Retainer Kit (See Figures thru for Handle End Options) Buna-N seals are standard for all Gresen valve assemblies. Work Section Service Kits include all the seals and back-up rings required to service one VPC work section, including spool seals. Do NOT install spool seals into VPC Solenoid Work Sections. SAE porting standard. Contact the Gresen factory in Minneapolis for optional porting. The work section housing and spool are matched and are not sold separately. Warning: If you are using the free flow (F) spool configuration in a cylinder lift application, it must be used in conjunction with a load holding device. A load holding device will prevent the load from free falling when the spool is in the neutral position. A free falling load could cause serious bodily injury or property damage if the holding device is not installed. Be sure to clear the work area prior to testing the cylinder lift application to avoid a potential dangerous situation. Continuous Back-Up Rings are installed at the factory using special sizing tools. It is Not necessary to replace the original Back-Up Rings unless they have been damaged. See Page for Back-Up Ring Preparation and Installation procedures. Model V0 Service and Parts Manual (Catalog No. SC-0) Rev: 0--00

V0P Parallel & V0T Tandem -Way Solenoid Work Sections B A [SOL] Schematic (-Way Shown) [EPC] Schematic (-Way Shown) B A T OC P T OC P Bonnet Seals (Located in Work Section Body) Figure. V0P Parallel & V0T Tandem -Way Solenoid Work Sections (Parallel Housing Shown) K- V0 Solenoid Work Section Service Kit - Buna-N O-Rings 0xxx 0xxx 0000 000 xxx xxx xxx xxx 00 00 000 000 V0RP Parallel Solenoid Work Section Housing (Not Serviceable) V0RT Tandem Solenoid Work Section Housing (Not Serviceable) -Way Solenoid Spool (Not Serviceable) -Way Free Flow Solenoid Spool (Not Serviceable) On/Off [SOL] Solenoid Actuator Assembly - A End (See Figure ) Proportional [EPC] Solenoid Actuator Assembly - A End (See Figure ) On/Off [SOL] Solenoid Actuator Assembly - B End (See Figure ) Proportional [EPC] Solenoid Actuator Assembly - B End (See Figure ) K-00 Load Check Plug Kit (See Figure ) O-Ring Seal O-Ring Seal O-Ring Seal Buna-N seals are standard for all Gresen valve assemblies. Work Section Service Kits include all the seals and back-up rings required to service one VPC work section, including spool seals. Do NOT install spool seals into VPC Solenoid Work Sections. SAE porting standard. Contact the Gresen factory in Minneapolis for optional porting. The work section housing and spool are matched and are not sold separately. Warning: If you are using the free flow (F) spool configuration in a cylinder lift application, it must be used in conjunction with a load holding device. A load holding device will prevent the load from free falling when the spool is in the neutral position. A free falling load could cause serious bodily injury or property damage if the holding device is not installed. Be sure to clear the work area prior to testing the cylinder lift application to avoid a potential dangerous situation. Model V0 Service and Parts Manual (Catalog No. SC-0) Rev: 0--00

Manual Positioner and Actuators will NOT work on Solenoid Type Work Section housings. V0P & V0T Solenoid Work Sections with Handle B A [SOL-IH] Schematic (-Way Shown) B A [EPC-IH] Schematic (-Way Shown) T OC P T OC P Bonnet Seals (Located in Work Section Body) Figure 0. V0P & V0T Solenoid Work Sections with Handle K- V0 Solenoid Work Section Service Kit - Buna-N O-Rings 0xxx 0xxx 0000 000 xxx xxx xxx xxx 00 000 00 000 V0RP Parallel Solenoid Work Section Housing (Not Serviceable) V0RT Tandem Solenoid Work Section Housing (Not Serviceable) -Way Solenoid Spool (Not Serviceable) -Way Free Flow Solenoid Spool (Not Serviceable) On/Off [SOL] Solenoid Actuator with Handle - A End (See Figure ) Proportional [EPC] Solenoid Actuator with Handle - A End (See Figure ) On/Off [SOL] Solenoid Actuator Assembly - B End (See Figure ) Proportional [EPC] Solenoid Actuator Assembly - B End (See Figure ) K-00 Load Check Plug Kit (See Figure ) O-Ring Seal O-Ring Seal O-Ring Seal Buna-N seals are standard for all Gresen valve assemblies. Work Section Service Kits include all the seals and back-up rings required to service one VPC work section, including spool seals. Do NOT install spool seals into VPC Solenoid Work Sections. SAE porting standard. Contact the Gresen factory in Minneapolis for optional porting. The work section housing and spool are matched and are not sold separately. Warning: If you are using the free flow (F) spool configuration in a cylinder lift application, it must be used in conjunction with a load holding device. A load holding device will prevent the load from free falling when the spool is in the neutral position. A free falling load could cause serious bodily injury or property damage if the holding device is not installed. Be sure to clear the work area prior to testing the cylinder lift application to avoid a potential dangerous situation. Manual Positioner and Actuators will NOT work on Solenoid Type Work Section housings. Model V0 Service and Parts Manual (Catalog No. SC-0) Rev: 0--00

-Way, -Position Series Work Sections -Way Free Flow B A -Way B A T OC P T OC P Figure. -Way, -Position Series Work Section 00 xxx 00 00 00 00 00 000 K-0 V0S Series Work Section Service Kit - Standard Buna-N O-Rings V0S Series Work Section Housing (Not Serviceable) -Way Series Spool (Not Serviceable) -Way Series Free Flow Spool (Not Serviceable) K-0 Spring-Return Spool Positioner Kit (See Figure ) K-0 Series Load Check Plug Assembly (See Figures thru for Options) K-0 Seal Retainer Kit (See Figures thru for Handle End Options) K-0 Spool Seal Assembly (Serviced in Spool Seal Kits - See Figure ) Work Section Service Kits include all the seals and back-up rings required to service one V0S Series work section. Contact the Gresen factory in Minneapolis for porting options. The work section housing and spool are matched and are not sold separately. Warning: If you are using the free flow (F) spool configuration in a cylinder lift application, it must be used in conjunction with a load holding device. A load holding device will prevent the load from free falling when the spool is in the neutral position. A free falling load could cause serious bodily injury or property damage if the holding device is not installed. Manual Positioners and Actuators will NOT work on Solenoid Work Section housings. Model V0 Service and Parts Manual (Catalog No. SC-0) Rev: 0--00

-Way, -Position Float Series Work Sections -Position Float B A T OC P Figure. -Way, -Position Series Float Work Section 0000 xxx 00 000 00 00 000 K-0 V0S Series Work Section Service Kit - Standard Buna-N O-Rings V0S Series Work Section Housing (Not Serviceable) -Way Series Float Spool (Not Serviceable) K-0 Series Float Spool Positioner Kit (See Figure ) K-0 Series Load Check Plug Assembly (See Figures thru for Options) K-0 Seal Retainer Kit (See Figures thru for Handle End Options) K-0 Spool Seal Assembly (Serviced in Spool Seal Kits - See Figure ) Work Section Service Kits include all the seals and back-up rings required to service one V0S Series work section. Contact the Gresen factory in Minneapolis for porting options. The work section housing and spool are matched and are not sold separately. -Position Spool Positioners and Actuators will NOT work on Float Work Sections. Model V0 Service and Parts Manual (Catalog No. SC-0) Rev: 0--00

V0LS Load Sensing Work Sections B B A B A T LS P -Way T LS P -Way T LS P -Way Free Flow Note: The Spring Pin and Load Sense Ball Are Not Serviceable Items. Do NOT Remove Them From The Valve Housing Figure. V0LS Load Sensing Work Sections 0xxx 000 00 00 00 000 000 000 K- V0 Work Section Service Kit - Standard Buna-N O-Rings V0LS Work Section Housing (Not Serviceable) -Way Load Sensing Spool (Not Serviceable) K- Spool Positioner Kit (See Figures thru for Positioner Options) K-00 Load Check Plug Assembly (See Figure ) K-0 Seal Retainer Kit (See Figures thru for Handle End Options) K-0 Spool Seal Assembly (Serviced in Spool Seal Kits - See Figure ) Load Sense Check Ball (Not Serviceable) Spring Pin (Not Serviceable) Buna-N seals are standard for all Gresen valve assemblies. Work Section Service Kits include all the seals and back-up rings required to service one V0 work section. SAE porting standard. Contact the Gresen factory in Minneapolis for optional porting. The work section housing and spool are matched and are not sold separately. Warning: If you are using the free flow (F) spool configuration in a cylinder lift application, it must be used in conjunction with a load holding device. A load holding device will prevent the load from free falling when the spool is in the neutral position. A free falling load could cause serious bodily injury or property damage if the holding device is not installed. Manual Positioners and Actuators will NOT work on Solenoid Work Section housings. Model V0 Service and Parts Manual (Catalog No. SC-0) Rev: 0--00