Filter-cooler circulation circuit with in-line filter according to DIN 24550

Similar documents
Filter cooler unit with inline filter according to DIN Type ABUKG. Contents. Features. RE Edition: Replaces: 50126

Hydraulic drive power unit Low noise compact unit Wispering power unit

Throttle and throttle check valve

Drive module. Table of contents. Features. Applications. RE 51145/06.12 Replaces: Type UPE 5

Motor-pump group. Features. Table of contents RE 51171/ Type ABAPG and ABHPG

Radial piston pump, fixed displacement

2-way flow control valve

Supply pressure compensator, direct operated

Fixed displacement vane pumps Types PVV and PVQ

Fixed displacement radial piston pump

迅捷 PDF 编辑器. Supply pressure compensator, direct operated RE 29231/ Type ZDC

Pressure reducing valve, pilot operated. Type DR. Features. Contents. RE Edition: Replaces: 02.03

Pressure relief valve, direct operated. Type ZDBY D, Z2DBY D. Features. Contents. RE Edition: Replaces: 01.09

Vane pump, direct operated Type PV7 A

Hydraulic drive power unit Low-noise compact unit Whispering power unit

Check valve. RE 21536/07.05 Replaces: Type Z1S. Size10 Component series 3X Maximum operating pressure 315 bar Maximum flow 100 l/min 1/6

Pressure reducing valve, pilot operated

Throttle check valve. RE 27518/10.07 Replaces: Type Z2FS

Check valve. Type S. Contents. Features. RE Edition: Replaces:

Proportional pressure reducing valve, pilot operated

Check valve cartridge Type M-SR

Throttle check valve. Type Z2FS. Contents. Features. RE Edition: Replaces: 10.07

Radial piston pump PR4 Series 1X

Proportional cartridge throttle valve, with inductive position transducer, pilot operated

Proportional pressure reducing valve, pilot operated

Proportional pressure relief valve with linear curve (Lvdt AC/AC)

Proportional pressure reducing valve, pilot operated, with inductive position transducer

Throttle and throttle check valve

IE3. Motor-pump groups. Type ABAPG and ABHPG. Features. Contents. RE Edition:

Check valve, pilot operated

Throttle check valve. RE 27526/04.08 Replaces: Type Z2FS

Hydraulic inch power brake valve LT 31

Return line filter for direct tank mounting Type ABZFR

Proportional pressure reducing valve, pilot operated

Radial piston pump PR4 series 1X

Pressure reducing valve, pilot-operated. Type Z3DR. Contents. Features. RE Edition:

Proportional flow control valve, with inductive position transducer

Pressure relief valve, pilot operated

Proportional pressure reducing valve, pilot operated

Proportional flow control valve, 2-way version

Check valve. Type S. Contents. Features. RE Edition: Replaces:

Proportional pressure relief valve, pilot operated

Block mounting filter, for vertical flange-mounting

Proportional pressure relief valve

Pressure reducing valve, direct operated

Pipe burst safety valve

Check valve, pilot operated

Reservoir oil filler/breather

Block mounting filter, for lateral flange-mounting

Pressure relief and feed valve, pilot operated. Type MHDBN. Features. Contents. RE Edition: Replaces:

Variable Vane Pump, Direct Controlled PV7...A Series 1X / 2X

Block mounting filter, for lateral flange-mounting

Pressure reducing valve, direct operated

4/3 proportional directional control valve, without position control, with on-board electronics (OBE)

Servo solenoid valves with on-board electronics (OBE)

Hydraulic primary unit Type ABPAG

4/2 servo solenoid valves with positive overlap and position feedback (Lvdt AC/AC)

Accumulator shut-off block. Type 0532VAW. Contents. Features. RE Edition: Replaces: 07.10

Proportional pressure reducing valve, pilot operated, with on-board electronics (OBE) and position feedback

Double throttle check valve Type Z2FS 10

Pressure relief valve, direct operated, with DC motor actuation. Type DBGT. Features. Contents. RE Edition:

Pressure reducing valve, direct operated

2-way flow control valve

Pressure reducing valve, direct operated. Type ZDR. Contents. Features. RE Edition: Replaces:

Twin throttle check valve

Pressure relief valve, pilot operated

Central Hydraulics Valve for Tractors with Priority Function for Steering, Trailer Brake and Pilot Oil Valve

Accumulator shut-off block. Type ABZSS. Contents. RE Edition: Replaces: 05.13

Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated

2-way flow control valve. Type 2FRM, 2FRH, 2FRW. Contents. Features. RE Edition: Replaces: 07.04

Proportional flow control valve, with integrated pressure compensator

Block mounting filter, lateral flange-mounting possible

Proportional pressure relief valve, directly operated, rising characteristic curve

Vane pumps, direct controlled Type PV7...A

Flow sharing control block in mono block / sandwich plate design M6-15

Proportional pressure relief valve, pilot operated

3/2 directional spool valve, direct operated with solenoid actuation

Flow sharing control block in mono block / sandwich plate design M6-22

Pressure relief valve, direct operated. Type DBD..K. Contents. Features. RE Edition:

Pressure relief valve, pilot operated

LUDV control block of sandwich plate design

Proportional pressure relief valve, pilot operated, with on-board electronics (OBE) and position feedback

Pressure sequence valve, direct operated

Throttle and throttle check valve

Pressure reducing valve, direct operated, with pressure monitoring

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 10.05

2/2 directional seat valve, direct operated with solenoid actuation

Pressure relief valve, pilot operated

Block mounting filter, for sandwich plate mounting

Check valve, pilot operated

Proportional pressure reducing valve, 3-way variant, pilot operated

Throttle check valve. Type Z2FS. Features. Content. RE Edition: Replaces: 04.08

Pressure reducing valve, pilot operated Type DR

Gerotor pump, fixed displacement volume

Directional spool valves, direct operated, smoothly switching, with solenoid actuation

Check valve, pilot operated

Proportional pressure reducing valve, pilot operated

Directional servo-valve of 4-way design

Check valve, pilot operated

4-way directional servo-valve

Transcription:

Filter-cooler circulation circuit with in-line filter according to DIN 0 RE 01/0.0 1/10 Type ABUKG Component series 1X with: circulation pump type PGF or type PVV el. motor, frame sizes 0 to 13 low-pressure in-line filter to DIN 0 plate-type heat exchanger electrically operated water valve HAD 3 Type ABUKG-..K-... (console mounting) HAD 3 Type ABUKG-..V... (tank top mounting) Table of contents Features Contents Page Features 1 Ordering code Circuit diagram 3 election table 3 Technical data Noise level guideline Cooling capacity curves Unit dimensions: Type ABUKG-..K... (console mounting) Type ABUKG-..V... (tank top mounting) Connection sizes for flanges and fittings Mounting options 9 pare and wear parts list 10 Compact circulation circuit with pump, mounted low pressure filter and plate-type heat exchanger Designed according to the modular principle Depending on the requirements, mounted on a console or on a mounting plate Application Any hydraulic system, in which heat is generated through power losses, requires active cooling during continuous operation. The dissipation capacity of the tank is often not sufficient to ensure a stable heat balance during long periods of operation. Due to their compact design, these circulation circuits can be mounted to the tank wall, on top of the tank or on other machine components. The basic elements are an internal gear pump of type PGF or a fixed displacement vane pump type PVV, a low-pressure filter and a plate-type heat exchanger. General The units are fitted with a low-pressure filter. Electrical clogging indicators signal when a filter element has to be changed. The water consumption depends on the utilisation of the power unit and the inlet temperature differential. The water supply for cooling purposes is regulated by an electrically operated water valve. Circulation units of version ABUKG-..K are fitted with a drip tray for collecting oil that is spilled during filter changes.

/10 Bosch Rexroth AG Industrial Hydraulics ABUKG RE 01/0.0 Ordering code ABUKG 1X E Filter-cooler circulation circuit Cooling capacity with inlet temperature differential of 30 K kw = 0. kw = 0 kw = kw = kw = 3 kw = 3 Design principle Console mounting Tank top mounting Component series 10 to 19 (10 to 19: unchanged installation dimensions Heat exchanger AB3-1/00-K-00- AB3-1/00-K-010- AB3-1/00-K-0- AB3-1/00-K-03- AB3-1/00-K-03- AB3-1/00-K-0- = K = V = 1X = 0K0 = 0K10 = 0K = 0K3 = 0K3 = 0K 1) For a detailed description of supply voltages, see AB-30 Order example: ABUKG-V-1X/0K//100LA0/10/E 0 = 90 = 100L = 13 = Water valve E = El. operated G1 In-line filter to DIN 0 Flow q V at p = 0. bar and HLP at 0 C = Without in-line filter 3 = q V = 3 L/min 100 = q V = L/min 10 = q V = 110 L/min 0 = q V = 0 L/min upply voltage (example) 1) A0 = 30/00V D/Y; 0V Y Number of pins = For example, -pin Motor frame size Version: K Version: V B3 0 B3 90 B3 100L B3 13 B 0 B 90 B 100L B 13 Pump size 13 = PGF-X/013RE01VE 1 = PVV1-1X/01RAUMB = PVV1-1X/0RAUMB 0 = PVV-1X/00RAUMB 9 = PVV-1X/09RAUMC

RE 01/0.0 ABUKG Industrial Hydraulics Bosch Rexroth AG 3/10 Circuit diagram Type ABUKG-..K... Type ABUKG-..V... B A 10 µm % 100% Water A WA b P B A 10 µm % 100% M 1 Water A WA b P a 1 M P 3 T a 3 P T 1 El. motor 3 Fixed displacement pump Pump mounting bracket + coupling Pressure measuring point In-line filter Hose Oil/water heat exchanger El. operated water valve election table: Filter-cooler circulation circuit The material numbers include all of the components shown on the circuit diagram! Cooling capacity q Vmax in L/min at 00 min -1 p max in bar Power at 00 min -1 El. motor Low-pressure filter size Cooler type 1 0. 0--A1 3 AB3-1/00-K-00-. 1.10 90--A0 100 AB3-1/00-K-010-3.0 100L--A0 10 AB3-1/00-K-0-10 3.0 100L--A0 10 AB3-1/00-K-03-3 3.00 100L--A1 10 AB3-1/00-K-03-3 13.0 13--B0 0 AB3-1/00-K-0- Cooling capacity Version for console mounting ABUKG-..K... Weight in kg Version for tank top mounting ABUKG-..V... Weight in kg R90101 0 R9010. R901013 R9010 R90101 R90109 R90101 R90100 R90101 9 R90101 90 3 R90101 10 R9010 13

/10 Bosch Rexroth AG Industrial Hydraulics ABUKG RE 01/0.0 Technical data (for applications outside these parameters, please consult us!) Line ports Oil side Connection thread to IO 119 Pipe connections to DIN 33 / IO 3 Flanges to IO 1 Water side Thread to IO /1 Type of piping Fitting to DIN 33 light / heavy series Hydraulic fluids Mineral oil HLP to DIN part (other hydraulic fluids on inquiry) Please observe our regulations and data sheet RE 00. Hydraulic fluid temperature range C 30 to 0, for other temperatures, please consult us Installation position Cooling medium Perm. operating pressures at inlet (absolute) Oil side Pump type PGF Pump type PVV bar bar Vertical Potable, process, stream and river water Cooling water requirement: V K = 0. x V oil [L/min] Heating (H O): ϑ = 1 x power loss (kw) / V K [ K] 0. to 3 0.3 to 1. Water side bar 1 (at least 3 to bar) Motor voltage / kw cooling capacity 30 / 00 V - 0 Hz to IEC 3; 0 V - 0 Hz or frequency 3 kw cooling capacity 00 / 90 V - 0 Hz to IEC 3; 0 V - 0 Hz Direction of rotation of pump Clockwise Water valve Electrically operated / directional water valve AB1-3 Controlling of water valve: e.g. with thermostat to AB31-1 Max. permissible degree of contamination of the hydraulic fluid Cleanliness class to IO 0 (c) Class 1/19/1 Filter rating µm 10 urface protection The components are provided with a primer coat! For installation, commissioning and maintenance of oil-hydraulic systems, please observe RE 0900! Further data sheets: AB 3-1 Heat exchanger oil / water system: Plate-type heat exchanger RE 1013 Internal gear pump type PGF, fixed displacement RE 1033 Fixed displacement pump types PVV and PVQ RE 00 Pressure filter to DIN 0 for installation in pressure lines, type ABZFD RE 10 Pump-motor group type ABUPG for circulation circuits The units are designed and manufactured in accordance with the harmonised EN standards / specifications. Noise level guidelines Cooling capacity Noise pressure level in db(a) 0, 3 Noise pressure level according to DIN 3 part 1 and 1; measurement distance 1 m Measured at 10 min 1 at an operating temperature of ϑ = 0 C Hydraulic fluid: Mineral oil HLP to DIN part

RE 01/0.0 ABUKG Industrial Hydraulics Bosch Rexroth AG /10 Cooling capacity curves The cooling capacity of the individual units differ depending on the water and oil inlet temperatures. The oil inlet temperatures selected were 0, and 0 C. ABUKG-0.-1X/... 13 ABUKG-0.-1X/... ABUKG-...--1X/... 1 11 Cooling capacity 3 C Cooling capacity 10 9 C Cooling capacity 0 1 1 1 1 C 10 1 10 0 30 3 0 3 10 0 30 3 0 10 0 30 3 0 Cooling capacity 3 3 33 31 9 3 1 19 1 13 11 ABUKG-.-1X/... C 9 10 0 30 3 0 Cooling capacity 0 3 3 0 1 1 ABUKG-.-1X/... C 10 0 30 3 0 Cooling capacity 0 0 3 3 0 1 1 ABUKG-3.-1X/... C 10 0 30 3 0

/10 Bosch Rexroth AG Industrial Hydraulics ABUKG RE 01/0.0 Unit dimensions: Type ABUKG-..K... (nominal dimensions in mm) L B3 B L L 3 H3 H 3 Ø1 100 B 13 H H1 30±0, T WA 1 0x B1 B 30 0 L±0, L3±0, L1 1 El. motor 3 Fixed displacement pump Pump mounting bracket + coupling Pressure measuring point In-line filter Hose Oil/water heat exchanger El. operated water valve Cooling Dimensions capacity L1 L L3 L L L 1) B1 B B3 B B 1) H1 H 1) H3 H 10 00 10 3 30 00 3 310 30, 0 11 3 330 0 30 1 1 390 10 10 0 0 1 30 30 11 1 00 0 110 30 19 0 0 1 3 0 390 10 9 30 11 11 0 0 110 1) Dimensions L, B and H are approximate dimensions. For connection sizes, T, and WA, see top of page. Tolerances according to: General tolerances to IO -mk Tolerancing principle to IO 0

RE 01/0.0 ABUKG Industrial Hydraulics Bosch Rexroth AG /10 Unit dimensions: Type ABUKG-..V... (nominal dimensions in mm) X X H H H H3 H H1 T WA 3 B1 B B B B3 1xØD T WA L3 13 1 L L L L L1 L 1 El. motor 3 Fixed displacement pump Pump mounting bracket + coupling Pressure measuring point In-line filter Hose Oil/water heat exchanger El. operated water valve Cooling capacity Dimensions L1 L L3 L L 1) B1 B B3 ØD H1 H H3 H H 1) H 1) 0 130 11 1 30 0 130 0 11, 1 9 1 390 0. 13 0 1 9 1 3 9 1 3 0 0 0 0 9 9 10 30 13, 19 191 3 110 10 1 3 3 0 10 100 190 00 0 10 391 3 1) Dimensions L, H and H are approximate dimensions. For connection sizes, T, and WA, see top of page. Recommended tank opening for ABUKG-..V-... L L L Tolerances according to: General tolerances to IO -mk Tolerancing principle to IO 0 B B 1xM B Cooling capacity Dimensions L L B B M 130 30 130 30 M10 B. / / / 0 0 0 0 3 10 10 10 10 M1 L Recommended min. material thickness = 1. x M

/10 Bosch Rexroth AG Industrial Hydraulics ABUKG RE 01/0.0 Connection sizes for flanges and fittings Cooling capacity uction port Threaded / flange connection Ø mm, AE 1 1/ - UNC 3 AE - UNC Oil outlet T Water - in Water - out WA Thread Thread Thread G1 G1 G1 Flange connection for suction line (nominal dimensions in mm) ØD1 B B1 Fig. 1 B Fig. B1 L3 L1 ØD1 L 0 H1 H H H1 ØD3 W1 Fig. 3 ) 1) ØD Ø0 ABUKG-..K-... Heat to be disspated ABUKG-..V-... Heat to be disspated Material number Material number x Ø 3 1 Dimensions B1 B L1 H1 H ØD1 ØD Fig. R900333 3 ). R90003 R900039 9.9 9.0 0 3. 3.0 13 1 R900999.3 3 R901010. 10 00.9 9 0.3 Dimensions B1 B L L3 H1 H ØD1 ØD3 Fig. R900333 3 ). R90030 9.9 9.0.. 3. 3.0.3 13 3 R90003. 10.9 9 0.3 1) Cut to required length ) Included in scope of supply

RE 01/0.0 ABUKG Industrial Hydraulics Bosch Rexroth AG 9/10 Mounting option The filter-cooler circuit of version ABUKG-..K-... is to be mounted preferably to the side of a hydraulic tank. eparate erection is also possible. The filter-cooler circuit of version ABUKG-..V-... is intended for mounting onto a hydraulic tank. It cannot be erected separately without a corresponding mounting fixture.

10/10 Bosch Rexroth AG Industrial Hydraulics ABUKG RE 01/0.0 pare and wear parts list Type Filter element Clogging indicator ABUKG-... Type Material number Type Material number 0 ABZFE-N003-10-1X/M-DIN R901031 0 ABZFE-N0100-10-1X/M-DIN R90103 3 ABZFE-N010-10-1X/M-DIN ABZFE-N00-10-1X/M-DIN R901033 R90103 ABZFV-EPU-M1X1-1X/-DIN R901031 Type Coupling ABUKG-... Type Material number 0 AB33-/KD 19-0/19X3 R900301 0 AB33-/KD -G (,3)/X0 R9000 3 AB33-/KD -G (,3)/-9 AB33-/KD 3-K (31,)/3 R900131 R90013 Hose (item ) Type ABUKG-K... ABUKG-V... ABUKG-... Type Material number Hose Material number 0 AB3-1/C-19/... R901... AB3-1/C-19/... R901... 0 AB3-1/C-19/... R901... AB3-1/C-19/... R901... AB3-1/C-/... R901... AB3-1/C-/... R901... AB3-1/C-/... R901... AB3-1/C-/... R901... AB3-1/C-/... R901... AB3-1/C-/... R901... 3 AB3-1/C-/... R901... AB3-1/C-/... R901... Bosch Rexroth AG Industrial Hydraulics Zum Eisengießer 1 91 Lohr am Main, Germany Phone +9 (0) 93 / 1-0 Fax +9 (0) 93 / 1-3 documentation@boschrexroth.de www.boschrexroth.de This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth AG. Without their consent it may not be reproduced or given to third parties. The data specifi ed above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The given information does not release the user from the obligation of own judgement and verifi cation. It must be remembered that our products are subject to a natural process of wear and aging.