CUREMASTER SUPER digital

Similar documents
HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

MAXMEYER VOC Low Gloss Clearcoats 0720, 0760

Compact Sine Inverter

The EFL 2000/1 & 2 User Guide Test Sieve Shaker. Contents

Product Data Sheet June 2014

Operating & Maintenance Instructions Thermobend Elite Range

Swirl Wheelbase and Interface Workshop Manual.doc

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

D.fm Page 1 Wednesday, March 5, :21 PM Raptor user manual

Installation manual portable distributors

Installation Instructions. QuickSilver Shifter. Fits: GM, Ford, Chrysler Transmissions See Application Guide for Specific Applications Part # 80683

Index. 1. Important safety instructions Overview of the lift Installation instructions Operation instructions 8-9

Compact System NRGS 11-2 NRGS Original Installation Instructions English

NON MAINTAINED TWIN SPOTLIGHT WALL MOUNT LED EMERGENCY LIGHT

TWIN FAN CONTROLLER. Models:- ITC and ITC-DS Maximum load : V 50Hz ~ 9A and V 50Hz 3 ~ 9A

Installation manual wall-mounted distributor

Instruction Manual & Specification

PIL0478 ISSUE 01/ 07/16

Light Truck MegaShifter

Z-Gate Universal Shifter

INSTALLATION DOCUMENTATION for EL-AT

58kHz AM Deactivator DB104 Instruction Manual V1.0

SCION tc ILLUMINATED DOOR SILLS Preparation

POWERHEAT TYPE AHT TERMINATION INSTRUCTIONS. Ref TK/AHT Issue C Date 16 August 1999

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

Lighting GENERAL INFORMATION. Daytime running lamps. Condensation. Stop lamps. Halogen headlamps. Reversing lamps. Bi-Xenon headlamps

Installation Instructions Z-Gate Shifter

INSTALLATION INSTRUCTIONS

Installation Instructions Right Hand Drive Megashifter

RIGID PENDANT. Phoenix Pipeline Products Limited. Installation, Operation and Maintenance Manual

Property of American Airlines

P HS EXPRESS CLEARCOAT

USER'S GUIDE. WiseHP11 SINGLE PHASE HIGH PRECISION AVR SERVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

OWNER'S MANUAL RED LINE EZ50

315W CMH COMPLETE GROW LIGHT SYSTEM [ V] USER MANUAL

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

FiberSource Q150. user manual P/N

Ultraviolet Fluorescent Lighting Fixtures WF-EM2B, WF-EM4B WF-EM2M, WF-EM4M WF-EM22D, WF-EM4D WF-EM2R, WF-EM4R WF-EMMIM

AIR FILTER MODEL NO: AF1000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO:

28W WORK LAMP Model: CTL28 Part No:

SERVICE MANUAL. Koala

Operating & Maintenance Manual

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

Sieve Shaker 200mm/300mm - 8/12 inch SV003

ATOTH-G Series BLDC Motor Controller. User s Manual

Maintenance Manual. 3-Inch Internal Valve. F660 Series

Technical Support (707)

INSTALLATION INSTRUCTIONS

Installation & User Instructions

June 2014 Product Information D8082

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

THIS PRODUCT IS FOR PROFESSIONAL LABORATORY USE ONLY USER'S MANUAL. WELLS ENGINE UNIT 230 VOLT Product No. U905, U906, U907, U908

Guidance to Installers of Viridian EV Charging Stations

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC AP

KV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2

Hurst VMATIC3 INSTALLATION

Installation Instructions Megashifter

Snapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

CARM INTERNATIONAL TOWING MODULES

Light Source User Guide

UNIVERSAL FLOOR SHIFT CONVERSION KIT

Lighting GENERAL INFORMATION. Daytime running lamps. Halogen headlamps. Stop lamps. Bi-Xenon headlamps. Reversing lamps

Product Information GRS Deltron Matt Clearcoat System

January 2007 Product Information D8080

MIRRORLITE RECESSED EMERGENCY LIGHTING

Technical Publications AWP. Operator's Manual. Fourth Edition, First Printing Part No

Technical Installation Manual

Cargolift 85 Pv Repair. Cargolift 90 Sa Standard. Cargolift 120 Saav Jumbo. Cargolift 120 F Drive-on IMPORTANT

Electric Vehicle Charging Station

Flashlights Unlimited Xenopus Electronix Deep Purple 405 Multimode Inspection Lantern Operations Guide

PRODUCT DESCRIPTION The Clearcoats D8115 (Matt) and D8117 (Semi-Gloss) are designed for use over Envirobase High Performance and GRS basecoats.

1 2 3a 3b THREADING CARD 9 10 ABC Office

Troubleshooting Guide: 355 Lights (12V)

Self-Testing Industrial Series

IR600 Infra-red Lamp

Maintenance Manual 3-INCH INTERNAL VALVE F660 SERIES

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC A

Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A

VT Oil-Free Range Operators Handbook

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

MODEL No s: PP3, PP3K

Whad 0.8, 1, 1.5 kva. Manuel d installation Installation manual. Part. LE05733AA-07/12-01 GF

Mightylite Elite 16W LED Wall Light with PIR

SPRAYBOOTH OVEN AUXILIARY AIR MOVEMENT DESIGN, OPERATION AND BENEFITS

APT14 Automatic Pump Trap Installation and Maintenance Instructions

INSTALLATION I N S T R U C T I O N S

PROFESSIONAL CORDLESS IMPACT SCREWDRIVER

DC Master 24/ A

PRO RATCHET UNIVERSAL SHIFTER

LDG6000SA DIESEL GENERATOR OWNERS MANUAL

Operating Manual Hyperion 924IPS. Short-Range DC Bar

Installation Instructions

INSTALLATION GUIDE AND USER MANUAL

Eazidraw Cordless. Installation & Set Up Instructions. Electric Blinds & Curtains

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

18V CORDLESS DRILL MODEL NO: CON18LiC

INSTALLATION & OWNER S MANUAL

Getting started with

Transcription:

CUREMASTER SUPER digital ASSEMBLY AND OPERATING MANUAL North America MODELS ETS 2d / ETS 3d / ETS 5d ETS 2dt / ETS 3dt / ETS 5dt FORM FM450 ISSUE 01 (VALID FROM 30/06/05) Edwin Trisk Ltd. 2006

WARNINGS PLEASE READ THESE INSTRUCTIONS THOROUGHLY BEFORE COMMENCING ASSEMBLY OR OPERATION OF THE MACHINE. FAILURE TO DO SO COULD RESULT IN DAMAGE OR INJURY FOR WHICH TRISK WILL ACCEPT NO RESPONSIBILITY OR LIABILITY. The Curemaster unit conforms to North American standard UL 499 THIS EQUIPMENT MUST BE EARTHED. REMOVE PACKING PIECES FROM CASSETTE HEADS BEFORE USE. DANGER TO REDUCE THE RISK OF EXPLOSION, DO NOT USE IN PAINT SPRAY BOOTHS OR WITHIN 10 FEET OF SPRAYING OPERATIONS, AS PER THE REQUIREMENTS OF UL499. THIS UNIT MUST BE OPERATED IN A WELL-VENTILATED AREA. ISOLATE MAINS SUPPLY BEFORE REMOVING COVERS. DO NOT MOVE THE UNIT AROUND USING THE MAINS CABLE. DO NOT MOVE THIS UNIT DURING OPERATION AS THIS MAY LEAD TO PREMATURE EMITTER FAILURE. CUREMASTER ETS 2d & ETS 2dt MUST BE PROTECTED BY A 16A FUSE. CUREMASTER ETS 3d, ETS 3dt, ETS 5 & ETS 5dt MUST BE PROTECTED BY A 30A FUSE. THIS UNIT MUST NOT BE POINTED AT PERSONNEL OR EASILY FLAMMABLE SUBSTANCES. THE SUPPORT ARM EXTENDS FIERCELY WHEN THE CASSETTE ASSEMBLY IS NOT FITTED. Page 2 of 24

CONTENTS 1. INTRODUCTION...4 2. TECHNICAL SPECIFICATIONS...5 2.1. CUREMASTER SUPER digital ETS 2d (S214d) & ETS 2dt (S214dt)...5 2.2. CUREMASTER ULTRA digital ETS 3d (S310d) & ETS 3dt (S310dt)...5 2.3. CUREMASTER SUPER TWIN digital ETS 5d (S516d) & ETS 5dt (S516dt)...5 3. ASSEMBLY INSTRUCTIONS...6 4. OPERATING INSTRUCTIONS...12 5. PAINT CURING INFORMATION...17 5.1. PAINT CURE TIMES...17 5.2. PAINT CURE FAULT FINDING...18 6. GENERAL MAINTENANCE...19 6.1. MAINTENANCE SCHEDULE...19 6.2. BASIC MAINTENANCE PROCEDURES...20 7. IN THE EVENT OF A FAILURE...22 IF IN ANY DOUBT ABOUT ASSEMBLY OR OPERATION OF THE UNIT PLEASE DO NOT HESITATE TO CONTACT YOUR DISTRIBUTOR OR THE TRISK SERVICE DEPT. Page 3 of 24

1. INTRODUCTION Congratulations on buying a TRISK branded product! Your unit is manufactured to the highest specifications in order to meet your needs. TRISK is the undisputed market leader in the manufacture of short-wave infra-red paint curing equipment for the automotive refinishing industry. The company now exports to over 40 countries with a wide range of static and mobile infra-red units. TRISK products are not only used in advanced bodyshops throughout the world but also by major car manufacturers including, GM, Ford, Daimler, Chrysler, Nissan, Toyota, Honda and Hyundai. Your product is designed to be energy efficient and versatile, while helping to produce the type of finish you would expect from a quality manufacturer. We are confident that TRISK will remain at the leading edge of developing infra-red technology. Please read through this operating manual before using the machine and afterwards store it in a safe place. Page 4 of 24

2. TECHNICAL SPECIFICATIONS 2.1. CUREMASTER SUPER digital ETS 2d (S214d) & ETS 2dt (S214dt) Rated Voltage: 220 / 240V, 60Hz, Single Phase Rated Input: (Nominal) 3 emitters, full power: 3300W (max) Heating elements: 3 quartz, tungsten filament, ruby sleeved Infra-Red Emitters Area of coverage: 100cm x 80cm / 39 x 31 Dimensions (Nominal): (Width): 66cm / 27, (Height): 164cm / 66, (Length): 150cm / 60 Weight: 50Kg / 110lbs 2.2. CUREMASTER ULTRA digital ETS 3d (S310d) & ETS 3dt (S310dt) Rated Voltage: 220 / 240V, 60Hz, Single Phase Rated Input: (Nominal) 3 emitters, full power: 4500W (max) Heating elements: 3 quartz, tungsten filament, ruby sleeved Infra-Red Emitters Area of coverage: 1m x 1.2m / 39 x 47 Dimensions (Nominal): (Width): 66cm / 27, (Height): 164cm / 66, (Length): 150cm / 60 Weight: 50Kg / 110lbs 2.3. CUREMASTER SUPER TWIN digital ETS 5d (S516d) & ETS 5dt (S516dt) Rated Voltage: 220 / 240V, 60Hz, Single Phase Rated Input: (Nominal) 6 emitters, full power: 6000W (max) Heating elements: 6 quartz, tungsten filament, ruby sleeved Infra-Red Emitters Area of coverage: 1m x 1.8m / 39 x 71 Dimensions (Nominal): (Width): 95cm / 38, (Height): 164cm / 66, (Length): 150cm / 60 Weight: 65Kg / 144lbs Page 5 of 24

3. ASSEMBLY INSTRUCTIONS Check that the electricity supply is compatible with the technical specifications of the machine as shown in section 2. If in any doubt about assembly or operation of the unit please do not hesitate to contact your distributor or the Trisk Service Dept. 1. Remove cassette assembly box from the main packaging together with the main upright column and arm assembly. Remove the base unit and attach castors with the braked castors at the rear of the base (see Fig. 1). Ensure that you have a flat floor and apply the brakes on the rear castors. Remove all packaging. CAUTION: DO NOT OPERATE GAS STRUT LEVER UNTIL THE CASSETTE ASSEMBLY IS FITTED ON THE ARM. THIS GAS STRUT IS PRESSURISED AND WILL EXTEND THE ARM FIERCELY WHEN THE LEVER IS DEPRESSED IF THE CASSETTES ARE NOT ATTACHED. Fig. 1 Fig. 2 2. To assemble the upright, undo the nuts and washers from the bolts at the base of the column. Carefully insert the column bolts into the corresponding holes in the base with the column control fascia to the rear (see Fig. 2). Refit washers and locknuts to column bolts by hand and then use a 19mm AF spanner to fully tighten. Do not over tighten. Test the upright for rigidity in relation to the base. 3. ETS 2d, ETS 2dt, ETS 3d & ETS 3dt Undo the ratchet lever from the end of the swivel bolt on the underside of the socket housing. Slide on the cassette assembly, refit the ratchet lever and tighten until the cassette assembly is fairly stiff to move (see Fig. 3). DIN plug - DIN socket (make sure that this is inserted in the correct orientation) Top cassette plug - Top Socket Middle cassette plug - Middle socket Bottom cassette plug - Bottom socket Page 6 of 24

Fig. 3 ETS 5d & ETS 5dt Remove the M12 plastic cap, locknut and washer from the pivot bolt on the underside of the socket housing. Position the cross-bar on the pivot bolt, refit the locknut and washer and tighten until the arm is fairly stiff to move (see Fig. 4). Fit the plastic cap onto the locknut. The cassette / backbar assemblies are colour coded (see Fig. 5) the left hand cassette assembly is marked red, the right-hand assembly is marked green. Attach the cassette assemblies to the cross-bar using the M12 bolts, washers and locknuts supplied (see Fig. 4) and tighten the locknuts until the cassette assemblies are fairly stiff to move. Fit the plastic caps onto the locknuts. DIN plug - DIN socket (make sure that this is inserted in the correct orientation) See Fig. 5 for further lamp to arm connection details Page 7 of 24

Fig. 4 MARKED RED CROSS - BAR MARKED GREEN CENTRE CASSETTE LEFT CENTRE CASSETTE RIGHT Fig. 5 Page 8 of 24

4. ETS 2d, ETS 2dt, ETS 3d, ETS 3dt, ETS 5d & ETS 5dt THIS EQUIPMENT MUST BE GROUNDED These units are fitted with mains plugs at the factory. If it is necessary to fit an alternative plug it should be connected as described below: Cable core Connection 1. BLACK LINE 2. WHITE NEUTRAL 3. GREEN GROUND If in any doubt about electrical fittings please consult a qualified electrician or contact Edwin Trisk Service Department. Page 9 of 24

ETS2/3d Front Panel Display Flash Off Timer Distance Indicator Activate Button Full Bake Timer IR Lamp Selector Buttons Start Button Pause/Stop Button Isolating Switch/Circuit Breaker Page 10 of 24

ETS5d Control panel layout Display Flash Off Timer Distance Indicator Activate Button Full Bake Timer IR Lamp Selector Buttons Start Button Pause/Stop Button Isolating Switch/Circuit Breaker Page 11 of 24

4. OPERATING INSTRUCTIONS Ensure lamps are not energised before making any adjustments. 1 SWITCH ON UNIT AT MAINS CIRCUIT BREAKER. (Display will illuminate.) 2 ANGLE INFRA-RED CASSETTES TO POINT DIRECTLY AT SURFACE TO BE CURED. 3 PRESS DISTANCE INDICATOR BUTTON ON CONTROL PANEL TO ACTIVATE DISTANCE INDICATOR. (Ensure that the overspray cover is not obstructing the distance sensor.) 4 MOVE INFRA-RED CASSETTES TOWARDS THE PANEL, STOPPING WHEN THE GREEN LIGHT SHOWS ON THE CASSETTE ASSEMBLY (24 / 600mm OR 26 / 650mm ETS 3d & ETS 3dt) THE DISTANCE CAN BE MODIFIED, IF REQUIRED, TO SUIT THE MATERIAL BEING CURED OR THE DISTANCE INDICATOR FUNCTION CAN BE TURNED OFF BY PRESSING THE DISTANCE INDICATOR BUTTON AS ABOVE Page 12 of 24

5 LOCK REAR WHEELS OF UNIT TO AVOID ACCIDENTAL MOVEMENT. 6 ADJUST FLASHOFF TIMER TO SET DESIRED FLASHOFF TIME ON DISPLAY. (This is the duration of half power output from the emitters.) 7 ADJUST FULLBAKE TIMER TO SET DESIRED FULLBAKE TIME ON DISPLAY. (This is the duration of full power output from the emitters or, if applicable, the duration that the temperature control system will control the temperature.) 8 9 IMPORTANT OPERATIONAL POINT: Adjust the thermal sensor so that it is pointing at a flat part of the panel to be cured. The sensor must be at a right angle (or normal) to panel surface. This ensures the unit sees the correct temperature of the panel. Failure to do this will result in imprecise temperature control. Set the desired temperature on the temperature controller. TEMPERATURE SETTING DETAILS. The temperature at which the paint cures must be set as follows: The figure displayed by the controller is the temperature the unit can see, i.e. the panel temperature. Pressing the DOWN or UP buttons momentarily displays the target panel temperature, this is the temperature the unit will heat the panel up to. To adjust the target temperature, simply hold down the * button and press DOWN or UP until the desired temperature is displayed. USE LAMP SELECTION BUTTONS TO SELECT THE REQUIRED Page 13 of 24

NUMBER OF INFRA-RED EMITTERS TO COVER THE RESPRAYED AREA. (A RED light shows that the emitter is selected.) 10 PRESS START BUTTON TO BEGIN CURING. Page 14 of 24

CURING WILL PROCEED AS FOLLOWS: FLASHOFF PERIOD, During the FLASHOFF time, the emitters will pulse: this is normal. The display shows flash-off time remaining: Flash-off can be finished early by turning the flash-off timer to 0. FULLBAKE PERIOD, During the FULLBAKE time, if your unit is NOT a temperature control model, the emitters will be on continuously. If your unit does have the function to control the temperature, the emitters will pulse to keep the temperature constant. The display shows full-bake time remaining: Full-bake can be finished early by turning the full-bake timer to 0. CURING COMPLETE, When the curing cycle is complete, an ALARM will sound and the display will flash. The unit is now ready to be used again. PAUSING THE CURING PROCESS, The curing process can be paused at any time by pressing the PAUSE/STOP button once. The emitters switch off and the display shows time remaining: (Curing is resumed by pressing the START button.) Page 15 of 24

STOPPING THE CURING PROCESS, To abort the curing process and allow the timers to be set again, press the PAUSE/STOP button TWICE. The emitters will switch off and the unit is then ready to be set again. THE DISTANCE CHECKING FEATURE DISTANCE CHECKING will take place while curing. If the emitters are positioned closer than 475 mm from the painted surface, the emitters will be turned off and an ALARM will sound. When the emitters are moved to the correct distance, curing will resume automatically. Display indicates too close. (DISTANCE CHECKING can be disabled by pressing the DISTANCE INDICATOR BUTTON.) IM PORTANT NOTES: 1. The distance indicator produces an audible clicking sound when operating. This is normal. 2. The distance sensor must not be obstructed by the overspray cover when the machine is being used. (The cover should be closed when not in use to prevent overspray contamination.) 3. Timer knobs will not move during curing. The display shows the time remaining. Page 16 of 24

5. PAINT CURING INFORMATION 5.1. PAINT CURE TIMES The table below gives a guide for different finishes: PAINT TYPE FLASH OFF* FULL BAKE Filler/Stopper -- 5-7 minutes Primer -- 6-8 minutes Hi-Build -- 10-12 minutes Solid-Colour -- 11 minutes Clear Coat -- 12 minutes Waterborne Primer -- 8-10 minutes Waterborne Basecoat -- 5 minutes *All the above times are based upon FULL BAKE cycles although some coatings require a FLASH OFF / half power setting. This is normally used on coatings with a high film build and also on dark colours. This setting is used for approximately 5 minutes before Full Bake. For detailed curing information, contact your local TRISK distributor for a data sheet. Paints from Akzo Coatings, B.A.S.F., De Beer, Du Pont / Herberts / Spies Hecker (DPC), P.P.G. / ICI / Maxmeyer (NEXA), Sherwin Williams and Martin Senour are included in this information. Page 17 of 24

5.2. PAINT CURE FAULT FINDING PROBLEM POSSIBLE CAUSE POSSIBLE SOLUTION SOLVENT POPPING Unit too close to panel Insufficient flash off time Paint system has a fast thinner Move unit further away Increase flash off time Use a standard or slow thinner UNDER CURE OR SOFTNESS OF THE PAINT FILM Unit too far away Insufficient bake time Excessive film weight Move unit closer Increase full bake time Apply lighter coats SOFTNESS ON EDGES OF REPAIR Repair too large for I.R. unit Split area into two, move unit for 2nd application. If flash off is used, it will not be necessary on 2 nd application DIFFICULTY IN Too long on bake cycle Reduce cure time POLISHING OUT DIRT NIBS Unit too close to panel Move unit further away UNEVEN CURE IR cassettes not shaped to contours of repair Adjust IR cassettes for even heat distribution Page 18 of 24

6. GENERAL MAINTENANCE 6.1. MAINTENANCE SCHEDULE TASK CHECKING PERIOD Ensure that all operators are fully trained for use of equipment Continuously Ensure that equipment is grounded Continuously Check Infra Red lamps for cracks (lamps OFF) and functionality Daily Check reflectors for correct positioning and imperfections Weekly Check fasteners for suitable tensions Weekly Check fasteners between cassette and arm Weekly Ensure that all warning labels are in place and easily legible Weekly Inspect all wires, cables and sockets for imperfections Weekly Check internal wiring for imperfections Monthly Check gas strut for adequate force and support Monthly Grease castors Yearly Page 19 of 24

6.2. BASIC MAINTENANCE PROCEDURES REFLECTOR CLEANING 1. Disconnect the unit from the mains power supply. 2. Allow the cassette to cool down to room temperature if necessary. 3. Remove the contamination on the reflector using a soft cloth with a solvent such as IPA or Methylated Spirits. 4. Allow 15 minutes for the solvent to dissipate before switching the unit back on. INFRA-RED EMITTER REPLACEMENT 1. Check that the replacement has the correct voltage and wattage ratings. Check the old emitter end caps if in doubt. 2. Ensure that the unit is disconnected from the mains power supply. 3. Remove the wire grille from the front of the cassette. 4. Remove the self-tapping screws that hold the side reflectors into the cassette. A small screwdriver will be necessary to lift the side reflector from the cassette. 5. When the side reflector is removed, take note of the cable positions before removing the old emitter. 6. The in-line connectors can be separated by hand, but a better solution is to use two pairs of long nosed pliers; one to hold each connector when separating the wires. 7. Fit the new Infra-Red Emitter to the sockets in the cassette. To avoid touching the ruby sleeve with bare hands, use tissue paper when handling. 8. Reconnect the Infra-Red Emitters to the cassette wiring, taking care to replace the wires in the original positions. 9. Fit the side reflectors and then the clean ruby sleeve and reflectors with IPA or Methylated Spirits. 10. Refit the grille. 11. Allow 15 minutes for the solvent to dissipate before switching the unit back on. Page 20 of 24

MAINS CABLE REPLACEMENT 1. Ensure that the unit has been disconnected and isolated from the mains supply, i.e. remove mains plug from the supply. 2. Remove the 6 screws that hold the cable gland cover to the column. The cover can be eased away from the column, exposing the connections to the mains cable. 3. Disconnect the mains input cable from the terminal block on the gland cover. 4. Cut the tie wrap holding the cables to the terminal block. 5. Disconnect the mains cable earth from the cover earth stud. 6. Undo the clamping nut on the spiral gland to release the old mains cable. 7. Make sure new mains cable is of the same type as the original cable. 8. Strip the sheath 11 / 270 mm. from the cable before inserting into the spiral gland. 9. Fasten cable clamp onto sheath of mains cable allowing a minimum of 0.2 / 5mm of sheath to extend beyond cable gland. 10. Refit cable tie wrap to tidy cables. 11. Tighten nut on spiral gland. 12. Connect cables as below CABLE CORE BLACK WHITE GREEN CONNECTION LINE NEUTRAL GROUND If in any doubt about any electrical fitting please contact your local qualified electrician or contact Edwin Trisk service department. Page 21 of 24

7. IN THE EVENT OF A FAILURE Please note the following details before phoning your TRISK distributor: 1. SERIAL NUMBER* 2. MODEL NUMBER 3. DATE OF PURCHASE 4. EXPLANATION OF PROBLEM 5. LOCATION OF DAMAGED PARTS 6. HOW THE DAMAGE WAS CAUSED *To be found at the base of the upright Page 22 of 24

THIS PAGE IS LEFT BLANK INTENTIONALLY Page 23 of 24

ISSUE 1 Edwin Trisk Ltd 2006 HEDSON NORTH AMERICA Call toll free on 1-866-41-TRISK (1-866-418-7475) TEL: 905-339-3990 FAX: 416-352-5738 EDWIN TRISK LTD 8 9 BLEZARD BUSINESS PARK SEATON BURN NEWCASTLE UPON TYNE TYNE & WEAR NE13 6DS UNITED KINGDOM TEL: +44 (0) 845 113 5522 FAX: +44 (0) 845 113 5511 E-mail: infrared@trisk.co.uk Web: www.trisk.co.uk Page 24 of 24