Stud connection system HSK

Similar documents
CONTA-CONNECT SUPPLEMENTS

CONTA-CONNECT. High-power stud terminals HSK. a b

DOUBLE-LEVEL TERMINAL BLOCKS SRKD SSLD

Stud terminals. Overview Stud terminals WF / WFF. Stud terminals

CONTA-CONNECT. Double-level terminal blocks ZRKD 2,5 Double-level protective earth terminal ZSLD 2,5

CONTA-CONNECT. Overview. Overview... 2 Our company... 3

Powermate Range pitch 7.00 Powermate Range pitch 7.00

SHIELD-CONNECTION CLIPS SAB

FEED-THROUGH TERMINALS SDK

CONTA-CONNECT. Disconnect terminals TRK/STK 2/TK

SCREW-TYPE DISTRIBUTION BLOCKS

SCREW-TYPE DISTRIBUTION BLOCKS

Female socket block, Screw connection, No. of poles: 12, Width: mm, Colour: Green

Datasheet. Approvals. Technical data. Feed-through terminal WK 4 / U BLUE /V0. General. Technical data. Connection Data

8WH2 Spring-Loaded Terminals

8WH6 ipo Installation Terminals

Data sheet... OMNIMATE Signal - series LM LM 5.00/04/90 3.5SN OR BX

Terminal blocks with clamping yoke and screw connection system

Datasheet. System pitch mm (0.400 inch) - SU/BU BUZ 10.16HP/02/180F AG BK BX

8WH2 Spring-Loaded Terminals

Bolt connection terminal blocks OTTA, UHV, HV. General information

Data sheet. W-Series WDU 4 SL/EN

Han K 3/0, K 3/2 / Han HC Modular. Contents Technical characteristics Han K 3/0, Han K 3/ Inserts Han K 3/0, Han K 3/

Crimpmate Range pitch 5.00

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 high voltage contacts Quick and easy assembling Protection class IP68 acc.

CRITO Connection technology. Double and triple T and TCC section busbars

UK 6-FSI/C. Extract from the online catalog. Order No.:

Data sheet... W-Series WPE 4

Class R 250V and 600V modular ferrule and knifeblade fuse blocks

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 High voltage contacts Quick and easy assembling Protection class IP68 acc.

Castellated/Hex Nut. Insert Retaining Ring. Contact Insert

FUSE BASES NH FUSE BASES 690V 160A 160A

PCB plug-in connectors

Class J modular ferrule and knifeblade fuse blocks

General characteristics and technical data Series MCS

Terminal Blocks Product Catalog Terminal Block Supplement. Introduction. 8WH6 ipo Plug-In Terminals. 8WH6 ipo Installation Terminals

Directory chapter 03 DIN Power (to 15 A) Types H, H 3, MH , MH Technical characteristics type H

Datasheet. W-series terminal with clamping yoke connection WDU 4

Standard Buccaneer IP68 BUCCANEER FOR POWER BUCCANEER POWER

RoHS 2011/65/EU ISO 9001 ISO BS OHSAS 18001:2007 GREEN ELECTRONICS CIF. Connectors

INNOZED D0 fuse-bases with touch protection

RockStar HighPower. Contents. RockStar HighPower Introduction C.2 C.1

Contents Technical characteristics Han A Technical characteristics Han 3 A with HARAX Termination

RoHS 2011/65/EU ISO 9001 ISO BS OHSAS 18001:2007 GREEN ELECTRONICS CTF. Connectors

Data sheet... W terminal earth terminal WPE 4

Snap-in covers I Voltage taps

- 1 - General ordering data Order No

Magnetic Overcurrent Circuit Breaker

Han ES Press. Features. Description. Removal of conductor. Size 6 B - 24 B

Datasheet. W-series terminal with clamping yoke connection WDU 2.5 RT

RoHS 2002/95/EC GREEN ELECTRONICS CVF. Terminal Blocks and Connectors for Printed Circuit Boards ISO 9001 ISO BS OHSAS 18001:2007

RAFIX 22 QR. General data. Content

Datasheet. BL/SL 5.08 series BLF 5.08/02/180 SN OR BX

CSF - CSM CONNECTORS. Functional characteristics. RoHS 2011/65/EU. Brief description. Dimensional class: low. Standard colour: green

Fuse & Switch. BUCHANAN Terminal Blocks. Product Facts High Density Blocks. Fuse Blocks. Switch Blocks. Common Features of 300 & 0300 Series

Fuseblocks. Voltage Ratings: Ampere Ratings: Leakage Current: Catalog/system number Torque Range System Number

POLYAMIDE SCREW CLAMP TERMINAL BLOCKS

The specified data apply only if actuators/signal indicators are combined with contact blocks and lamp sockets within the same product range.

PT 2,5-QUATTRO-PE. Extract from the online catalog. Order No.:

Terminal Blocks. Section 12. Control Catalog 12-1

400 Series Buccaneer BUCCANEER POWER. bulgin

HK-003,HC SERIES HK-003 HCSERIES. Modular Heavy-current connector WAIN 12-01

Status Date Prepared Reviewed Endorsed Approved

Contents Technical characteristics Han A Technical characteristics Han 3 A with HARAX Termination

Section 10: Terminal Blocks

Terminal blocks with Push In connection technology. Product Information

INNOZED D0 fuse-bases with touch protection

3/2 Introduction. Unequipped Distribution Boards (Flat Pack) 3/6 8GK1 surface-mounting distribution boards

RoHS 2002/95/EC GREEN ELECTRONICS CRM. Terminal Blocks and Connectors for Printed Circuit Boards ISO 9001 ISO BS OHSAS 18001:2007

Rittal RiLine60. The fascinating 60 mm system of the future assembly-friendly, time-saving, individual and modular. including.

Switches. Common Used Terminology:

POLYAMIDE SCREW CLAMP TERMINAL BLOCKS

Feed-through terminal, 2.5 mm², Tension clamp connection, Wemid, dark beige, TS 35

Datasheet. W-series terminal with clamping yoke connection WSI 6

PANEL PANEL MOUNTING COMPONENTS

Fuseology. Fuse Holders, Fuse Blocks, Power Distribution Blocks & Surge Suppression. Optima Fuse Holders & Overcurrent Protection Modules.

Studded Power Feed Thru Terminal Blocks

Power distribution components

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

LDG-S. Busable Enclosures for DIN-rails. Installation widths 22.5 mm and 45 mm

PT 2,5-TWIN/1P BU. Extract from the online catalog. Order No.:

6000 Series Buccaneer. Secure, quick connector mating and release. 30 twist locking Tamperproof lock prevents accidental un-mating

PT 2,5-TWIN/1P BU. Extract from the online catalog. Order No.:

Extra functions. Phone: Fax: Web: Accessories P-Series. Terminals, P-Series

Printview: Stackable PCB terminal block; 16 mm²; Pin spacing 15 mm; 1-pole; CAGE CLAMP ; commoning option - Item No.

Moisture-proof cable branch boxes Ceiling distribution boxes Lamp suspension boxes Wall boxes Concrete wall boxes and accessories

7000 Series Buccaneer

Single foot switches - PX and PA series

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

RiLine mm system technology for the global market

Up to 60 A Class R 250 V and 600 V ferrule power distribution fuse blocks

RoHS 2011/65/EU ISO 9001 ISO BS OHSAS 18001:2007 GREEN ELECTRONICS MSP. Terminal Blocks

POLYAMIDE SCREW CLAMP TERMINAL BLOCKS

Content Modular terminals for high-temperature applications Nuclear power terminal blocks erminal Blocks T D.1

Safety switches with solenoid and separate actuator

Short form catalogue. Motor protection & control

Powerline. Single Power Connectors. Ten 47 Limited

W-series W-series W-series sets standards! W-series offers advantages 1) Easy project planning 3) Time-saving potential distribution

4000 Series Buccaneer

Technical Brochure. Rotary Type Installation Switches A, 500 V. Brochure OT_M 22 GB D Low Voltage Products

Transcription:

CONTA-CONNECT system HSK The newest generation of stud terminals from CONTA-CLIP offers secure connections for all energy-transmitting applications. Depending on the conductor cross-section, stud terminals can be used with threaded studs from M5 to M12. The rated current ranges from 76 A to 269 A with a rated voltage of 00 V. The wire connection range is from 0,2 mm² to 120 mm². Wires with crimped cable lugs are applied to threaded bolts and then connected securely by tightening the hex nut. Optimal security is guaranteed by the low voltage drop and by the use of self-extinguishing material with a V0 (UL94) flammability rating. Designed for mounting onto TS 35 DIN rails, the stud terminals can be adapted with accessories such as TW partitions and AD covers to suit application requirements. These products are easy to use. They also stand out with their cost-optimized line of accessories which results in reduced storage costs and assembly times. 186

system HSK Features a Base terminal HSK CONTA-CLIP stud terminals can be arranged as required on standard TS 35 DIN rails in accordance with EN 60715. b Partition plates TW Special TW partitions can be securely snapped into the terminal housing. This allows for good visual and electrical separation of the terminals. In addition, they are ready for fitting with snap-on covers. c SPECIAL TERMINALS a b d e c Covers AD The AD covers can be snapped on, simply and securely, to the matching clips in the partitions. In this quick and reliable way, touch-safe protection of the terminal points is always guaranteed. d End stop ES 35/K/ST The ES 35/K/ST end stop grips both sides of the DIN rail with steel clamps. They are a secure method of mechanical attachment in terminal rail design. The plastic PA 6.6 housing of the brackets encapsulates the metal parts. Handling 1 Stud terminals: Up to four wires can be connected easily. Cable lugs are crimped onto the wire ends to facilitate the connection. The cable lugs should be aligned opposite each other when there are multiple lugs per side. When the nut is tightened, the flats of the cable lugs clamp together and a secure connection is ensured. e Labelling Marking The stud terminals have a labelling surface which is optimally suited for our Pocket-Maxicard PMC (PMC BSTR 6/30) standard marking systems. 2 Stud terminals: Cable lugs are crimped onto the wire ends to facilitate the connection. The cable lugs are placed on the studs between the shake-proof washer and the busbar. The cable lugs should be aligned opposite each other when there are two lugs per stud. When the nut is tightened, the flats of the cable lugs clamp together and a secure connection is ensured. 187

CONTA-CONNECT High-power stud terminals HSK The features in detail Stud sizes from M5 to M12 Wire with cable lug acc. to DIN 46234 up to 120 mm 2 Up to four cable lugs per stud can be connected Easy to use One-stud terminals: Put the cable lug on the stud between the base washer and the shake-proof washer Twin-stud terminals: Put the cable lug on the stud between the busbar and the shake-proof washer By tightening the steel nut, the cable lug forms a contact with the other cable lug or with the busbar. (B/B versions) Cross-connections 2- and 3-pole designs Potential distribution between the different sizes is possible Designed for the rated current of the corresponding stud terminal Clearly saves time with quick potential distribution Terminal carriers made from Polyamide 6.6 V0 Self-extinguishing, UL94-V0 flammability class Creepage-current protected, CTI = 600 Temperature resistance: -40 to +120 C Spec. contact resistance: 13 Ohm/cm Spec. surface resistance: 15 Ohm/cm Temp. index, mechanical: 120 C (at 0.8 mm) Temp. index, electrical: 120 C (at 0.8 mm) Relative temperature index, electrical: 130 C (at 0.8 mm) Pollutant-free Secure handling Touch-protection provided by partitions and yellow covers Standards Secure contacts Maintenance-free, later tightening of the nut is not needed High contact strength and vibration resistance from the safety/spring washer Direct contact of cable lugs, or contact via copper busbar The following standard terminal block requirements are fulfilled: EN 60947-7-1 EN 124-1 DIN EN 61373 188

High-power stud terminals HSK Handling and accessories The use of TW partition plates The HSK B single-stud terminals and the HSK B/B twinstud versions make use of two TW partitions. The partitions can be adjusted to the rated cross-section by using the predetermined breakage points. For your further assistance, the TW partitions list the cross-section range and additional dimension lines. Remember that the clearance and creepage distances for a rated voltage of 00 V, dependent on the corresponding cross-section, must be followed. HSK installed with TW partition plate and AD cover Simple breaking off of the TW partition TW partition with dimension lines SPECIAL TERMINALS Snapping on the partition plates to the HSK highpower stud terminals You can snap on the TW partition plates and the HSK stud terminals by using the locking pegs on the partition. The pegs lock into the foot of the stud terminals. Snapping together the TW partition with a highpower HSK stud terminal Using the AD covers An individual AD cover is available for each width of stud terminal. Their length takes into consideration the creepage and clearance distances on the twin-stud terminals. If the covers are to be used with the one-stud versions, you can shorten the cover by breaking it along the breakage points. For your further assistance, the AD covers have additional dimension lines on them. Locking pegs are used to mount the AD cover. The cover snaps in securely from above to the TW partition plates. Thus a high degree of touch-safety is guaranteed. Simple breakage with the AD cover AD cover with dimension lines 189

High-power stud terminals HSK system HSK 16/M5 B CONTA-CONNECT HSK 35/M6 B HSK /M8 B Foot can be snapped on TS 35 DIN rail Housing made from polyamide 6.6 UL 94-V0 Connection diagram M5 M6 M8 Connection type Size (L x W x H) with TS 35 x 7.5 mm Size (L x W x H) with TS 35 x 7.5 mm with TW/AH Type Type/colour Colours available Rated data, in compliance (Approvals on page xxx ) Rated voltage, V Rated current, A Rated cross-section mm 2 /AWG Rated surge voltage kv / Contamination degree Plug gauge acc. to EN 60947-1/flamm. class UL 94 Connection data Contact wire range, mm 2 Stud size Clampable cable lug DIN 46234/1 cable lug per side mm DIN 46234/2 cable lugs per side mm DIN 46235/1 cable lug per side mm DIN 46235/2 cable lugs per side mm Torque, Nm Features Material of insulated housing Temperature range Number of cross-connection channels Test pick-off Accessories Partition plate TW up to 00 V Partition plate TW up to 00 V for insul. cable lugs AD cover profile Cross-connector Q 2 poles Cross-connector Q 3 poles Cross-connector Q, from M6 to M8 2 poles Cross-connector Q, from M6 to M 3 poles End stop ES Quick marking PMC SB 67 x 13 x 55.5 67 x 13 x 58 HSK 16/M5 B BG 17000 CSAus CSA 00 00 00 76 60 60 16-0 16 M5 0,1-16 0,1-16 6,0-6,0-2,0-4,0 8,5 TW 16-120 BG 17018 316 20 AD 16 YE 17019.8 Q2/16 17008.0 Q3/16 17009.0 312 298 298 20 0 67 x 16 x 55.5 67 x 16 x 58 HSK 35/M6 B BG 17001 CSAus CSA 00 00 00 125 115 115 35 14-2 35 M6 2,5-35 2,5-35 6,0-35 6,0-25 3,0-6,0 12,4 TW 16-120 BG 17018 316 20 AD 35 YE 17020.8 312 Q2/35 170.0 298 Q3/35 17011.0 298 Q2 HSK 35/M6 - M8 17028 299 Q3 HSK 35/M6 - M/2 17029 299 20 0 67 x 21 x 63.5 67 x 21 x 66 HSK /M8 B BG 17002 CSAus CSA 00 00 00 1 125 125 14-1/0 M8 2,5-2,5-6,0-35 6,0-35 6,0-12 16,9 TW 16-120 BG 17018 316 20 AD YE 17021.8 312 Q2/ 17012.0 298 Q3/ 17013.0 298 Q2 HSK 35/M6 - M8 17028 299 20 0 190 More accessories starting on page 264.

HSK 120/M B HSK 120/M12 B HSK 35/M6 B/B HSK /M8 B/B HSK 120/M B/B M M12 M6 M8 M 67 x 32 x 73.5 67 x 32 x 76 HSK 120/M B BG 17003 UL CSA 00 00 269 220 120 -Kcmil 2 120 M 67 x 32 x 73.5 67 x 32 x 76 HSK 120/M12 B BG 17004 UL CSA 00 00 269 220 120 -Kcmil 2 for 120 M12 67 x 16 x 55.5 67 x 16 x 61.5 HSK 35/M6 B/B BG 17005 UL CSA 00 00 125 35 14-2 35 M6 67 x 21 x 63.5 120 x 21 x 71.5 HSK /M8 B/B BG 17006 UL CSA 00 00 1 14-1/0 M8 67 x 32 x 73.5 156 x 32 x 78.5 HSK 120/M B/B BG 17007 UL CSA 00 00 269 120 -Kcmil 2 120 M SPECIAL TERMINALS 6-120 6-120 - 95-95 - 20 20,0 6-120 6-120 - 95-95 14-31 20,0 2,5-35 2,5-35 6,0-25 6,0-25 3,0-6,0 12,4 2,5-2,5-6,0-35 6,0-35 6,0-12 16,9 6-120 6-120 - 95-95 - 20 20,9 TW 35-120/B/B BG 17022 TW 16-120 BG 316 20 17018 AD 120 YE 316 20 17026.8 Q2/120/ 313 20 17014.0 Q3/120/ 299 17015.0 299 Q3 HSK 35/M6 - M/2 17029 299 0 TW 35-120/B/B BG 17022 TW 16-120 BG 316 20 17018 AD 120 YE 316 20 17026.8 Q2/120/ 312 20 17016.0 Q3/120/12 299 17017.0 299 0 TW 35-120/B/B BG 17022 316 20 AD 35 YE 17020.8 312 Q2/35 170.0 298 Q3/35 17011.0 298 Q2 HSK 35/M6 - M8 17028 299 Q3 HSK 35/M6 - M/2 17029 299 20 1 1 0 TW 35-120/B/B BG 17022 316 20 AD YE 17021.8 312 Q2/ 17012.0 298 Q3/ 17013.0 298 Q2 HSK 35/M6 - M8 17028 299 20 1 0 TW 35-120/B/B BG 17022 316 20 AD 120 YE 17026.8/20 Q2/120/ 17014.0/ Q3/120/ 17015.0/ 313 299 299 Q3 HSK 35/M6 - M/2 17029 299 20 1 0 191

CONTA-CONNECT High-power stud terminals HSK B...B/B The newest generation of HSK B B/B stud terminals from CONTA-CLIP offers secure connections for all energy-transmitting applications. Depending on the wire cross-section, stud terminals can be used with threaded studs from M8 to M16. The rated current ranges from 192 to 415 amps, with a rated voltage up to 00 volts. The wire connection range is from 6 mm 2 to 240 mm 2. Wires with crimped cable lugs are applied to threaded bolts and then connected securely by tightening the hex nut. Optimal security is guaranteed by the low voltage drop and by the use of self-extinguishing material with a V0 (UL94) flammability rating. Designed for mounting onto TS 35 DIN rails, the stud terminals can be adapted with accessories such as TW partitions and AD covers to suit application requirements. 192

High-power stud terminals HSK B...B/B Features a base terminal HSK CONTA-CLIP stud terminals can be arranged as required on standard TS 35 DIN rails in accordance with EN 60715. b Partition plates TW To safely separate the potentials, CONTA-CLIP offers three different types of partitions in various heights fitting to each terminal. These are fitted securely in place between the individual terminals by means of the pegs integrated into the terminal base. c SPECIAL TERMINALS e b d a c Covers AH The transparent AH covers offer a simple and safe method for protecting terminals and wires from accidental touch. They are securely screwed into the flanges built into the TW partition plates. The following product tables list the selection of TW partitions and the dimensions of the mounted terminal rails. d End stop ES 35/K/ST The ES 35/K/ST end stop grips both sides of the DIN rail with steel clamps. They are a secure method of mechanical attachment in terminal rail design. e Labelling Marking The stud terminals have a labelling surface which is optimally suited for our Pocket-Maxicard PMC (PMC BSTR 6/30) standard marking systems. 193

CONTA-CONNECT High-power stud terminals HSK B... B/B The features in detail Stud sizes from M 8 to M 16 Wire with cable lug acc. to DIN 46234 up to 240 mm 2 Up to three cable lugs per stud can be connected with the singlebolt variants Easy to use Place cable lugs on the studs Base washer and spring washer are then placed over When the steel nut is tightened, the flats of the cable lugs clamp together. Cross-connections 2-pole design Can be used for all stud terminals Designed for the rated current of the stud terminal Clearly saves time with its quick potentials distribution Housing made from polyamide 6.6 V0 Self-extinguishing, UL94-V0 flamm. class Creepage-current protected, CTI = 600 Temperature resistance: -40 to +120 C Spec. contact resistance: 13 Ohm/cm Spec. surface resistance: 15 Ohm/cm Temp. index, mechanical: 120 C (at 0.8 mm) Temp. index, electrical: 120 C (at 0.8 mm) Relative temperature index, electrical: 130 C (at 0.8 mm) Pollutant-free Standards The following standard terminal block requirements are fulfilled: EN 60947-7-1 EN 124-1 DIN EN 61373 194

Handling accessories Secure handling Touch-safe protection because of TW partition plates and transparent AH covers Secure contacts Maintenance-free, later tightening of the nut is not needed High contact strength and vibration resistance from the spring washer Direct contact of cable lugs, or contact via copper busbar SPECIAL TERMINALS Cross-connections/Potential distribution With neighbouring stud terminals, it is possible to implement potential distribution over two-pole QS cross-connection rails. The cross-connections are each designed for the rated current of the terminal. They are simply placed together with the cable lug over the stud. When using the cross-connection rails, do not use the partitions between the individual terminals. A cover over the terminals is not possible here. Unlocking the DIN rails The size of the terminal feet allows for a secure fit on a DIN rail with a thickness of at least 1.5 mm. A spring slider in the foot is used for a simple, quick snap-on and snap-off from the DIN rail. 195

High-power stud terminals HSK system HSK 70 B CONTA-CONNECT HSK 95 B HSK 1 B Foot can be snapped on TS 35 DIN rail Housing made from polyamide 6.6 UL 94-V0 Connection diagram M 8 M M 12 Connection type Size (L x W x H) with TS 35 x 7.5 mm Size (L x W x H) with TS 35 x 7.5 mm with TW/AH Type Type/colour Colours available Rated data, in compliance (Approvals on page xxx ) Rated voltage, V Rated current, A Rated cross-section mm 2 /AWG Rated surge voltage kv / Contamination degree Plug gauge acc. to EN 60947-1/flamm. class UL 94 Connection data Contact wire range, mm 2 Stud size Torque, Nm Features Material of insulated housing Temperature range Accessories Partition plate TW AH protective hood BS mounting screw for the AH QS cross-connection rail End stop ES Quick marking PMC SB 75 x 40 x 93 75 x 40 x 97 HSK 70 B BG 1174 00 192 70 2/0 70 M 8 6-12 TW 97 BG 2380.0 AH 40 transparent 2381.0 313 0 24.0 75 x 40 x 93 75 x 40 x 97 HSK 95 B BG 1175 00 232 95 3-4/0 95 M -20 TW 97 BG 2380.0 AH 40 transparent 2381.0 313 0 2411.0 96 x x 8 96 x x 138 HSK 1 B BG 1176 5 00 309 1 2-6/0 1 M 12 14-31 TW 138 BG 1178.0 AH transparent 2382.0 313 0 2412.0 196 More accessories starting on page 264.

HSK 240 B HSK 70 B/B HSK 95 B/B HSK 1 B/B HSK 240 B/B M 16 M 8 M M 12 M 16 96 x x 8 96 x x 138 HSK 240 B BG 1177 5 00 415 240 2/0-0 75 x 40 x 58 75 x 40 x 71 HSK 70 B/B BG 1170 00 192 70 2/0 75 x 40 x 58 75 x 40 x 71 HSK 95 B/B BG 1171 00 232 95 3-4/0 96 x x 78 96 x x 97 HSK 1 B/B BG 1172 5 00 309 1 2-6/0 96 x x 88 96 x x 97 HSK 240 B/B BG 1173 5 00 415 240 2/0-0 SPECIAL TERMINALS 240 M 16 25-60 70 M 8 6-12 95 M -20 1 M 12 14-31 240 M 16 25-60 TW 138 BG 1178.0 AH transparent 2382.0 313 0 2413.0 TW 71 BG 2379.0 AH 40 transparent 2381.0 313 0 24.0 TW 71 BG 2379.0 AH 40 transparent 2381.0 313 0 2411.0 TW 97 BG 2380.0 AH transparent 2382.0 313 0 2412.0 ES 35/H/ST BG TW 97 BG 2380.0 AH transparent 2382.0 313 0 2413.0 ES 35/H/ST BG 197