Palletiser Functional Safety Specification

Similar documents
Bulletin 190S/191S Direct On-Line Compact Combination Starters

Safeguarding Applications and Wiring Diagrams Cat 1 Stop with Guardlocking Interlock and Proximity Sensors TLSZR-GD2, 872C, GLP, PowerFlex 45

Safety Application Note

Bulletin 190E/191E Direct On-Line Eco Starters

NHP SAFETY REFERENCE GUIDE

The Complete Range up to 710 kw. Overview Contactors

Safety Control HR1S-AC. Safety Relay HR1S-AC

NHP SAFETY REFERENCE GUIDE

PowerFlex 700H and 700S AC Drives Frame 9 Main Fan Capacitor Replacement Kit

pg. 2 Using Sensing Edges in Safety Applications How sensing edges work Understanding the fail-safe concept

Universal Gate Box with Safety Interlocking TYPE: UGB-KLT FEATURES & APPLICATION:

Inputs Safety Outputs Auxiliary Outputs Terminals Reset Type Power Supply Cat. No. Fixed. Block Diagram Y41 MSR30RT/RTP

EOS4. Safety level: Type 4 SIL 3 SILCL 3 PL e Cat. 4

EOS 2. Safety level: Type 2 SIL 2 SILCL 2 PL d Cat. 2

P33T Series Redundant Safety Exhaust Valve ENGINEERING YOUR SUCCESS.

KD LV Motor Protection Relay

UNI EN ISO EN

F3S-TGR-KHL1/-KHL3/-KHL3R

Selection Guide for SMC-Delta and SMC-3. A New Dimension in Motor Control

Heavy-Duty Safety Interlock Switch with Guard Door Locking

ZB0050 / ZB0051 ZB0070 / ZB0071

APPLICATIONS. Automatic assembling lines Palletizers and Depalletizers

Gate Box with Safety Interlocking & RFID UGB-KLT Operating Instructions

Safety Exhaust Valve Integration Guide

Universal Gate Box with Safety Interlocking TYPE: UGB-KLT FEATURES & APPLICATION:

PowerFlex DC Drive - Frame C Field SCR Module

P33T Series Redundant Safety Exhaust Valve ENGINEERING YOUR SUCCESS. Bulletin 0700-B13.

Bulletin 100-C Contactors. Bulletin 193-E Solid-State Overload Relays. Bulletin 193-T Bimetallic Overload Relays

GLM SERIES CONTROL Users Manual Rev:

SDS Enclosed Star-Delta Starter User Guide

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

IDEM Solenoid Interlock Safety Switches

Protecting People, Industry and Productivity

Modern Safety Systems and Advanced Fluid Power Solutions

PowerFlex DC Drive - Frame A Pulse Transformer Circuit Board

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

CAUTION CM-SE CM-S21 CM-S41

AUTOMATION AND CONTROL TRADE 19 TAR SANDS

MONITORED HYDRAULIC VALVE SYSTEMS

DEEP SEA ELECTRONICS PLC

CENTRIFEEDER ELECTRONICS

Achieving Required Safety Levels Using a Pneumatic Safety Exhaust Valve

Safety. Detection. Control. EOS4 - EOS2. Type 4 - Type 2 Safety Light Curtains. Product catalogue

CTi Automation - Phone: Fax: Web:

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Sense7-series Non-contact coded safety switch

Safety switches with solenoid and separate actuator

MKey9-series Safety Interlock Switch with Guard Locking

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2

FS1A Safety Controller

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

GKR/GKL Series Dual Entry Solenoid Key Operated Safety Interlock Switch

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

4 x 0-10Vdc Channels Fused 24V o/p terminals for actuator power Direct or buffered output signals

Safety. Detection. Control. EOS4 - EOS2. Type 4 - Type 2 Safety Light Curtains. Product catalogue. Issue 1

Safety. Detection. Control. EOS4 - EOS2. Type 4 - Type 2 Safety Light Curtains. Product catalogue

SOLENOID VALVES AND PNEUMATIC VALVES

ABB JOKAB SAFETY Products. Material handling industries Machine safeguarding products

M-Series 415 & in 1 Elevator Light Curtain. Installation Manual

Datasheet. Electrical Switching / Locking

Technical Documentation

Welcome to the presentation about safety functions of ACS880 functional safety, FSO- 12 Safety functions module.

TECHNICAL MANUAL AND ELECTRONICAL MODULE REGULATION VVVF-4 +

CEN/TC 198. EN :2005/FprA1:2010. Date: CEN/TC 198. Secretariat: DIN

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Safety Contacts. Locking Type. Power Supply. Operating Radius, Min

4 Redundant Control System

Tina 10A/B/C Adaptor unit

Safety switches with solenoid and separate actuator

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Safety door-handle system STS

Components for safety applications

Description. Positive safety relays

Session Four Applying functional safety to machine interlock guards

Solenoid interlock AZM 200 The non-contact interlock.

Redundant Control System

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

Safety interlock switch MKey

Light grids and light curtains LCA

I ntroduction. VA-7450 Electronic Terminal Unit Valve Actuator. Features and Benefits

This specification describes the minimum requirements for a hoist maintenance safeguard (HMS) system for mine hoists.

Bulletin 825 SMM Smart Motor Manager

Safety Door Handle System with SIDENT Safety Switch Ref. no , -11, -12

REVISED ATM72 Auto Transfer Module

1370 DC Loop Contactors and Lug Kits

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

An Investment in Plant Floor Safety. 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches

Quick Start Guide TS 910 & TS 920

D4JL/D4JL-SK40. Guard Lock Safety-door Switch/Slide key

Operating instructions Solenoid interlock AZM About this document. Content

SPECIFICATIONS NB SKILLS TRADE 19 AUTOMATION AND CONTROL

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Power Supply

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Contents. Part no.: MLC510R Safety light curtain receiver

Process switches and PLC circuits

Bulletin 193-T1 Bimetallic Overload Relays

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

MANUAL ELECTRIC FIRE PUMP CONTROLLERS METRON SERIES M450

SE-3SCR-LM MANUAL MOTOR LOAD MANAGER

FMC-1/2 Tina Muting unit

Transcription:

Palletiser Functional Specification R

Non-muted Light Curtain (generally in-feed conveyor), pages 6...7 +V DC * L-PSxxxxYD Power/ Fault Reset 800F-F6 800F-AL Auto Signal To PLC Start/Restart 800F-F8 800F-AL +V In In Info Info GPI0 GPI0 GPI0 GPI0 Lamp SR RJ 0R-P6AGS-ANNR RJ 0V OSSD OSSD In-feed conveyor motor * Jumper required for normal operation +V In In Info Info GPI0 GPI0 GPI0 GPI0 Lamp SR 0R-PNANS V DC Com Overview This document has been developed to provide guidance on the integration of a complete safety related control system for palletiser / depalletiser equipment. The specification covers the implementation from input devices to final power element. The diagrams in this document should be used in conjunction with the additional recommendations detailed in: EN 600- - of machinery - Electrical equipment of machines EN - - of packaging machines, Part - palletisers and depalletisers When implemented correctly the circuits described in this whitepaper will comply with the requirements for PLe to EN ISO 89-; SIL to IEC 606; and category to EN 9-. Index Pages Palletiser System... Light Curtain System 6...7 S S Blue Red S S Yellow SensaGuard 0N-Z6H Pink S SR P 0R-H79 S6 Brown Grey (0A) 0T SRUEXXXX (Details P) Gate interlock switch if required to raise required performance level to e (0A) S S S S S SR 0P 0R-H78 S6 (0A) (0A) General Access System 8...9 Personnel Access 0... SR00 connection details for solenoid release key

R uted Light Curtain (generally out-feed conveyor), pages... +V DC Power/ Fault Reset 800F-F6 800F-AL uting Sensors RightSight Transmitted Beam EF-EEZB-F (Source) EF-R9PBV-F (Receiver) 889D-FAC- S S uting Lamp (Clear) Control Tower Stack Light 8E-TL7 8E-BP0 8E-ABCAP * L-PSxxxxYD Auto Signal To PLC Start Over-ride +V In In Info Info GPI0 GPI0 GPI0 GPI0 Lamp SR RJ 0R-P6AGS-ANNR RJ 0V OSSD OSSD * Jumper required for normal operation +V In In Info Info GPI0 GPI0 GPI0 GPI0 Lamp SR 0R-PNANS V DC Com General Access Functional Description, pages 8...9 Additional feedback if required e.g. robot, for signalling the solenoid release unit +V DC E-Stop 800F-T 800F-AL 800F-X0S x S S S S SR0P 0R-H76 S6 S S S S Emergency stops may be connected in series to a single input - refer to page 8 for further details S S A Y Y0 Y Y A Y0 Y Y S Y Y Reset 800F-F6 800F-AL SR0 Ready 00S-C* SR0P 0RH80 00S-C* Additional outputs if required e.g. Robot, etc + - Solenoid onitor Out-feed conveyor motor Additional feedback if required e.g. Robot Solenoid onitor For Solenoid Release Out-feed conveyor, additional auxilliaries for signalling the solenoid release unit In-feed conveyor, additional auxilliaries for signalling the solenoid release unit achine control output see page 8 for additional information V DC Com

Palletiser Functional Description Circuit Status The light curtain is clear. The muting sensors are clear. The outputs of the safety relay are de-energized, and the motor is off. achine S S Object uting Lamp Uni-directional muting: uting requires the material to break the beams and light curtain in a certain sequence: sensor S first then S and then the light curtain. Only if the beams are broken in sequence and then clear in sequence will the light curtain allow material through without initiating a machine stop. Operating Principle The SR can be configured for automated conveyor applications, where an object moves through a light curtain out of a hazardous area. With L-type two sensor muting, the object can move only in one direction. STARTING: Upon initial power-up, the start/restart button must be pressed to energize the outputs of the SR and attached SR extension relay. On the basis that all other conditions are clear this will start the motor. UTING: The object must block the sensor S and then S within the configured time limits prior to passing through the light curtain. The motor continues running during the muting operation. STOPPING: Obstructing the light curtain without blocking sensors S and S de-energizes the SR/ SR outputs. After clearing the light curtain, press the start/ restart button to re-energize the safety outputs of the SR/ SR. Clearing the light curtain can also be managed by activating the override function (pressing the spring-loaded key). LC Fault Detection Upon power-up, the connected GuardShield light curtain, as well as the SR, performs internal checks. If OK and the protection field of the connected GuardShield light curtain is clear, the outputs will turn on after the start signal. For power up, the muting sensor can be blocked. If so the outputs can be turned on, but the muting process cannot be activated because the muting sequence is not adhered to. The blocking material must be transported backwards, clearing the sensors first, or must be transported forwards through the protection field using the override functionality. While running, an incorrect sequence of the complete muting sequence (S->S->LC) or excessive time to move the object through the muting zone will de-energize the safety outputs of the SR/SR. The muting lamp blinks to indicate a fault has occurred. The exact fault can be read out using the USB-configuration tool. If the override functionality is activated in the SR, a simple re-activation of the start button may be used to manually move material through the conveyor. The outputs of the SR will then stay activated for the configured override time. If the protection field is cleared during that time the motor continues running. If the light curtain is still blocked after that time the SR will deactivate the safety outputs. Under circumstances where openings in the muted material lead to a failure in the muting sequence, a muting sensor delay function can be activated in the SR to accomodate the variability in the material. The outputs of the SR extension relay are connected to the SR0P input module. The SR0P base module monitors contactors and through the mechanically linked contacts connected in series. If one contactor welds or jams closed, the second contactor will stop the motor and the SR0P will detect the fault at the next attempt to start the motor. Ratings This circuit meets the safety performance requirements of Category of EN9-:998, PL e of EN ISO 89- or SILcl of IEC 606. This circuit executes a Category 0 stop.

R +V DC Power/ Fault Reset 800F-F6 800F-AL uting Sensors RightSight Transmitted Beam EF-EEZB-F (Source) EF-R9PBV-F (Receiver) 889D-FAC- Start/over-ride /added S S uting Lamp (Clear) Control Tower Stack Light 8E-TL7 8E-BP0 8E-ABCAP achine PREFERRED LC S S Object * L-PSxxxxYD Auto Signal To PLC +V In In Info Info GPI0 GPI0 GPI0 GPI0 Lamp SR RJ 0R-P6AGS-ANNR RJ 0V OSSD OSSD achine uting Lamp For Bi-directional applications use configuration below LC S LC uted Object S Conveyor * Jumper required for normal operation SR 0R-PNANS uting Lamp S S S SR 0P 0R-H78 S S S S SR0P 0R-H76 S S A Y S S S6 S6 S S S S A Y0 Y Y V DC Com Light curtain selection Protected Height (mm (in)) mm (0.in)) Number of Beams 0mm (.8in) Number of beams Catalogue Number 960 (7.8) 8 6 L-P*0960YD 080 (.) 7 L-P*080YD 00 (7.) 60 80 L-P*00YD 0 (.0) 76 88 L-P*0YD 0 (6.7) 9 96 L-P*0YD 60 (6.) 08 0 L-P*60YD 680 (66.) L-P*680YD 800 (70.9) 0 0 L-P*800YD 90 (7.6) 6 8 L-P*90YD * For mm resolution replace with an L and for 0mm resolution replace with an S. Example: L-PS0600YD Ie {A} Contactor Selection AC- AC- 0kW (0 Hz) Catalogue Number 9 00S-C09**BC. 00S-C**BC 6 7. 00S-C6**BC 00S-C**BC 0 6 00S-C0**BC 7 6 8./0 00S-C7**BC 8 00S-C**BC 60 00 00S-C60**BC 7 00 0 00S-C7**BC 8 00 00S-C8**BC ** To complete the Cat. No. select a coil voltage code from the table on page

Light Curtain Functional Description Circuit Status The light curtain is unobstructed. The SR outputs are off. The SR0P and associated SR0P outputs are off. The motor is ready to run. Operating Principle The SR is a multi-function relay. In this application the in-feed conveyor is protected by a safety light curtain and the SR is in a basic configuration. The outputs from the SR are connected to the contactors and through the SR0P expansion relay. If any of the inputs (muted safety light curtain, emergency stop(s), solenoid release switch or safety gate interlock switch if connected) are activated, the SR0P will de-energise contactors and regardless of the state of the SR. STARTING: Press the start button to energise the outputs of the SR. Press the reset button to energise the outputs of the SR0P and start the motor. STOPPING: Activating the light curtain de-energizes the SR safety outputs and the motor coasts to a stop. After clearing the light curtain, press the start/ restart button to reenergize the safety outputs of the SR. Fault Detection Upon power-up, the connected GuardShield light curtain and the SR perform internal checks. If OK and the protection field of the connected GuardShield light curtain is clear, the outputs will turn on in response to the start signal. Ratings This circuit meets the safety performance requirements of Category of EN9-:998, PL e of EN ISO 89- or SiLcl of IEC 606. This circuit executes a Category 0 stop. 6

R +V DC L-PSxxxxYD Power/ Fault Reset 800F-F6 800F-AL Start/Restart 800F-F8 800F-AL In-feed conveyor motor * Auto Signal To PLC +V In In Info Info GPI0 GPI0 GPI0 GPI0 Lamp SR RJ 0R-P6AGS-ANNR RJ 0V OSSD OSSD * Jumper required for normal operation SR 0R-PNANS Y0 Y Y SR0P SR0P S Y Y 0RH80 V DC Com Light curtain selection Protected Height (mm (in)) mm (0.in)) Number of Beams 0mm (.8in) Number of beams Catalogue Number 960 (7.8) 8 6 L-P*0960YD 080 (.) 7 L-P*080YD 00 (7.) 60 80 L-P*00YD 0 (.0) 76 88 L-P*0YD 0 (6.7) 9 96 L-P*0YD 60 (6.) 08 0 L-P*60YD 680 (66.) L-P*680YD 800 (70.9) 0 0 L-P*800YD 90 (7.6) 6 8 L-P*90YD * For mm resolution replace with an L and for 0mm resolution replace with an S. Example: L-PS0600YD Ie {A} Contactor Selection AC- AC- 0kW (0 Hz) Catalogue Number 9 00S-C09**BC. 00S-C**BC 6 7. 00S-C6**BC 00S-C**BC 0 6 00S-C0**BC 7 6 8./0 00S-C7**BC 8 00S-C**BC 60 00 00S-C60**BC 7 00 0 00S-C7**BC 8 00 00S-C8**BC ** To complete the Cat. No. select a coil voltage code from the table on page 7

General Access Functional Description Circuit Status The muted light curtain (out-feed conveyor) is unobstructed. The in-feed light curtain is unobstructed. The Solenoid switch inputs are also closed. The emergency stop is reset and the safety gate is closed. The SR0 outputs are off. The out-feed/ in-feed conveyor motors are stopped. Operating Principle: The SR00 is chosen as the safety relay for its modularity and ability to handle a variety of devices and to allow each device to be connected to an individual input. There is also the facility to add additional communication modules (not shown) to enable the transmission of individual status information to the machine control system. The schematic shown opposite has a light curtain (out-feed conveyor) connected to its inputs through a mute controller. The sensaguard switch mounted on the gate access, in addition to the trapped key solenoid release unit, will allow the integrity to achieve PLe, according to EN ISO 89-, if required. Normally PLd will be adequate.the emergency stop(s) can be wired individually to input modules to give enhanced diagnostics if required. However, connection in series to achieve PLd will be adequate in most circumstances. The additional light curtain controller (in-feed conveyor) is connected through the SR0P output module and acts as a permissive. If the emergency stop, or sensaguard/solenoid switch pairing are activated, these outputs will switch off regardless of whether the light curtain is obstructed or not. Ratings This circuit meets the safety requirements of PLe of EN ISO 89-, SILcL of IEC 606 and Category of EN 9-. This circuit executes a Category 0 stop. Solenoid Release Function The machine control output for the solenoid release, shown opposite, is switched by the standard machine control. To close this contact the control system will be signaled to stop (from an HI, etc) and this contact would latch in. The solenoid will be energised provided all the solenoid release auxiliaries are correct and the machine control output is present. On turning the key in the solenoid release unit the solenoid release signal is de-energised, but allows the key to be reinserted. Provided all the auxiliaries in the reset loop to the SR0P are in the correct state the machine can be reset. The inputs to the standard PLC are as follows: Contacts & on the SR0P base unit (0R-H76) would provide a N/C input to the standard PLC to signal a latch. Contacts &6 on the solenoid release unit (0T-SRUEXXXX) would provide a signal to the standard PLC to unlatch. STARTING: Press the reset button to energise the outputs of the SR0 and start the motor(s). STOPPING: Activating any one of the safety devices (light curtain, emergency stop, gate switch or solenoid release switch) deenergises the SR0 outputs and the motor coasts to a stop. If a safety device is activated, the motor cannot restart. Fault Detection Upon successful completion of internal checks on power up, the SR0P checks the input circuits. Short circuits from inputs to power, to ground, or to other inputs will be detected immediately by the SR0P and will prevent energisation or will de-energise all of its outputs. If one of the 00S-C safety contactors (,,, etc) fails in an actuated state, the motor will be stopped by the redundant contactor. This type of fault will be detected by the SR0P on the next attempt to start, and the SR0P will not energise its outputs when the reset button is pressed. 8

R +V DC Infeed conveyor Blue Red Yellow SensaGuard 0N-Z6H Brown Outfeed conveyor SR 0R-PNANS E-Stop 800F-T 800F-X0V SR 0R-PNANS S S Pink S S S SR P 0R-H79 Grey S6 S S S S S SR 0P 0R-H78 S6 S S S S S S A Y Y0 Y Y SR0P 0R-H76 S6 S S S S A Y0 Y Y S Y Y SR0P 0RH80 (0A) 0T SRUEXXXX (Details P) (0A) (0A) (0A) Reset 800F-F6 800F-AL SR0 Ready 00S-C* 00S-C* + - Solenoid onitor Solenoid onitor For Solenoid Release Gate interlock switch if required to raise required performance level to e V DC Com Light curtain selection Protected Height (mm (in)) mm (0.in)) Number of Beams 0mm (.8in) Number of beams Catalogue Number 960 (7.8) 8 6 L-P*0960YD 080 (.) 7 L-P*080YD 00 (7.) 60 80 L-P*00YD 0 (.0) 76 88 L-P*0YD 0 (6.7) 9 96 L-P*0YD 60 (6.) 08 0 L-P*60YD 680 (66.) L-P*680YD 800 (70.9) 0 0 L-P*800YD 90 (7.6) 6 8 L-P*90YD * For mm resolution replace with an L and for 0mm resolution replace with an S. Example: L-PS0600YD Ie {A} Contactor Selection AC- AC- 0kW (0 Hz) Catalogue Number 9 00S-C09**BC. 00S-C**BC 6 7. 00S-C6**BC 00S-C**BC 0 6 00S-C0**BC 7 6 8./0 00S-C7**BC 8 00S-C**BC 60 00 00S-C60**BC 7 00 0 00S-C7**BC 8 00 00S-C8**BC ** To complete the Cat. No. select a coil voltage code from the table on page 9

Personnel Access Functional Description Sensaguard non-contact safety interlock switch Removing key operates SRPCS Placing key in key exchange allows the door to be unlocked Control Panel Interlock Switch A STOP RESET anual Control (I or Pushbuttons) PERSONNEL DOOR E E STOP RESET D C B Once the machine has been signaled to stop, and the machine is in a quiescent state the solenoid will allow the primary key to be removed Each operator removes a key to prevent relocking of door while they are inside Solenoid release unit with primary and secondary key if required Stainless steel ejector key Dual personnel access lock with spring-eject secondary key 0

R At least one interlocked moveable guard (personnel door) shall be provided to allow operators and maintenance staff to enter the danger zone. The design of the personnel door or its interlocking device shall minimise the risk of the door closing accidentally i.e. closing the door shall require a deliberate action. The SRPCS for access shall be in accordance with the diagram left, and shall operate as follows: A manual control shall be supplied on the control panel A which controls the machinery in the danger zone (this control can be by means of a pushbutton operator or HI (Human achine Interface). When this is operated the machinery in that danger zone shall assume a quiescent state. Once in this state and provided that all energy sources are B isolated the control system shall allow the release of a key on the front of the control panel. Resetting and restarting shall be at the control panel but shall only be possible after the correct reversal of the sequence described above has been followed, and provided the feedback loop containing the solenoid monitoring on the solenoid locking switch is correct. Using this technique allows a maximum Performance Level of d (PLd) in accordance with BS EN ISO 89:008. If a PLe is required then an interlocking gate switch shall be used in accordance with drawing shown and the general access safety description. Generally, PLd is sufficient for NUK needs. In the Health and section of the Instruction anual the following information shall be given: i) It shall stress the importance of the operator taking the key with him into the machine (this is particularly important when more than one operator are within the palletiser) and not attaching the key to the guards e.g. with a piece of string. ii) It shall state that in the event that more than two persons require access at any one time, then a specific risk assessment and method statement shall be drawn up to ensure that all those who have entered the danger zone have left it before the machinery is set in motion. If more than one access gate is required, an additional key C can be incorporated if required. There shall be a unique key for each personnel gate. Removing the key initiates the SRPCS and puts the machinery in that danger zone into a safe state for entry. Solenoid release units - product selection Solenoid Voltage Contacts Nominal Current Catalogue Number V DC N.O. & N.C. 0T-SRUE N.O. 0T-SRUE0 0 VAC N.O. & N.C. 0T-SRUE N.O. 0T-SRUE0 0V AC N.O. & N.C. 0A 0T-SRUE N.O. 0T-SRUE0 N.O. & N.C. 0T-SRUE 0V DC N.O. 0T-SRUE0 N.O. & N.C. 0T-SRUE6 Substitute the desired primary code for this symbol i.e. AA, AB, etc The control panel key can then be taken to the personnel D gate and placed into a key exchange. This action unlocks the gate and releases a spring ejector key which the operator takes into the danger zone with him. This second key (personnel protection key) shall prevent the personnel door from being closed and locked behind him. It shall also prevent the reinsertion of the key required to allow the resetting and restarting the machinery in the danger zone. E Two keys shall be available at the gate allowing two operators to enter the danger zone.

SR00 connection details for solenoid release key S S S SR 0P 0R-H78 S S S6 S S S S SR0P 0R-H76 S6 S S S S S S A Y Y0 Y Y A Y0 Y Y S Y Y SR0P 0RH80 (0A) ) (0A) (0A) (0A) Reset 800F-F6 800F-AL SR0 Ready 00S-C* 00S-C* + - Solenoid onitor Solenoid onitor For Solenoid Release Access is only permitted if the palletiser out-feed contactors (&), in-feed contactors (&) and any additional feedback connections i.e. robot control have de-energised. Provided that all the output devices have de-energised, the solenoid is energised allowing the control panel key to be removed (and any additional keys if multiple gates are present/required). Once the solenoid is energised the key can be rotated to the off position. This disconnects contacts & and & on the isolator and switches the inputs on the SR0P to off (effectively performing an emergency stop command). The machine can only be energised provided all the control panel keys are inserted and rotated to the on position. On the basis that the solenoid monitoring contacts and any feedback connections are correct, the machine can then be restarted.

R Coil voltage codes Referenced from pages, 7 & 9 The Cat. No. as listed is incomplete. Select a coil voltage code from the table below to complete the Cat. No. Example: 0V, 60 Hz: Cat. No. 00S-C09**0BC becomes Cat. No. 00S-C09D0BC [V] 6 8 00 00-0 0 0 7 00 00-0 08 08-0 AC, 0 Hz R K V W X Y KP D P S KG L AC, 60 Hz Q J V X KP D KG H L AC, 0/600 Hz KJ KY KP KD KG KL [V] 0-0 0 0-0 0 77 7 80 80-00 00 00-0 80 00 0 600 AC, 0 Hz F VA T N G B C AC, 60 Hz A T I E N B C AC, 0/600 Hz KL KF KA KN KB 00S- C09...C [V] 9 6 8 60 6 80 0 0 0 0 Standard ZR ZQ ZJ ZW ZY ZZ ZB ZE ZD ZP ZS ZA ZF ZT With integrated diode DC DJ

www.rockwel lautomation.com Power, Control and Information Solutions Headquarters Americas: Rockwell Automation, 0 South Second Street, ilwaukee, WI 0-96 USA, Tel: ().8.000, Fax: ().8. Europe/iddle East/Africa: Rockwell Automation NV, Pegasus Park, De Kleetlaan a, 8 Diegem, Belgium, Tel: () 66 0600, Fax: () 66 060 Asia Pacific: Rockwell Automation, Level, Core F, Cyberport, 00 Cyberport Road, Hong Kong, Tel: (8) 887 788, Fax: (8) 08 86 Publication: SAFETY-AT06A-EN-P April 00 Copyright 00 Rockwell Automation, Inc. All Rights Reserved. Printed in USA.