Type MZ15. Operating Instructions. Bedienungsanleitung Manuel d utilisation

Similar documents
Type Operating Instructions. Bedienungsanleitung Manuel utilisateur

Type S030. Operating Instructions. Symbols used. INLINE fitting. Bedienungsanleitung Manuel d'utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type 5411, Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type 6213 EV, 6281 EV

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

Type 3360, Service Manual. Serviceanleitung Service Manuel

Type 3320, Service Manual. Serviceanleitung Service Manuel

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

EPS 16 ATEX 1121 X, IECEx EPS X Solenoid coil Type 06xx Magnetspule Typ 06xx Bobine magnétique Type 06xx. Operating Instructions

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Operating Instructions (from serial number 3000)

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type 2000, Operating Instructions. Bedienungsanleitung Manuel d utilisation

PTB 14 ATEX 2023 X, EPS 16 ATEX 1046 X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

EPS 16 ATEX 1111X, IECEx EPS X. Operating Instructions. Solenoid coil Type ACP016 Magnetspule Typ ACP016 Bobine magnétique Type ACP016

Type 8635 Remote-Positioner. Zusatzanleitung. English Deutsch Français

Type Pneumatic Control Unit. Operating Instructions

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Pneumatic Control Unit. Operating Instructions

Type 2030, 2031, 2031 K, 2032, 2033, 2037

Operating Instructions (from serial number )

Type 8798 Remote Sensor. Operating Instructions. Bedienungsanleitung Manuel d utilisation

Operating instructions

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Quickstart. English Deutsch Français

Type /2-way globe valve 2/2-Wege-Geradsitzventil Vanne à siège droit 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type 8644 AirLINE. Operating Instructions. Bedienungsanleitung Manuel d utilisation. With decentralized peripheral system ET200S (Siemens)

Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps

Type 3232, 3233, 3233 K, 3234, 3235, 3239

Type 8644 AirLINE. Operating Instructions. Bedienungsanleitung Manuel d utilisation. with I/O System 750 (Wago)

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

Type 2000, 2002, 2012

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

4 - SETTING UP THE MACROMAN CHARGING POSITION 4 Wall mounted 4 Workbench set-up 4

Swing Piston Compressors and Vacuum Pumps

Type 2730, 2731, 2731 K DN Operating Instructions. Bedienungsanleitung Manuel d utilisation

Operating instructions Accu Jet

Assembly and Maintenance Manual Type ASNU

i3000s/i2000 Flex AC Current Probe

Type 2060, 2061, 2063, 2064, Accessories. Zubehör Accessoires

KeContact P20. User manual

Siemens Drives & PLCs

Assembly and Maintenance Manual Type AS

The Efficient Solution for Pipetting up to 100 ml at once! USER'S GUIDE

BVS 13 ATEX E039X Type 8685 / Operating Instructions. Bedienungsanleitung Manuel d utilisation

362 Clamp Meter. Users Manual

Operating Instructions CYR52

Type 2030, 2031, 2031 K, 2032, 2033, 2037

User Manual Pocket Pro, Pro + ph

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

Oil-free piston compressors KK and piston vacuum pumps KV

HEINE NT4 MED V

Technical Documentation

USE AND INSTALLATION HANDBOOK

Type SE35. Quickstart. English. Flowmeter Flow Transmitter

Operating Instructions

SensoLyt 700 SensoLyt 700 SW

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Types 8025 / Operating Instructions. Bedienungsanleitung Manuel d utilisation. Flowmeter Durchflussmessgerät Débitmètre

PSU1 Power Supply Unit

Type 3280, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2-way motor valve 2-Wege-Motorventil Vanne motorisée 2 voies

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE

Switching DC Power Supply

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

Operator s manual Manuel d utilisation Manual de instrucciones. BLi520x BLi940x

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Installation Instructions (Translation) Marking. Description. Danger, warning and note symbols. Technical data. ANTARES ExtSet.

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130

Electrical linear actuator with safety function MC100FSR/24

Operating Instructions

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

testo 206 ph/ Temperature Measuring Instrument Bedienungsanleitung Instruction Manual

Micro Diaphragm Gas Sampling Pumps

Elektric actuator MC50/24-C

English. Instruction and operation manual S 212. Dew point sensor

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

Inductive conductivity meter

Bosch Smart Home. Door/Window Contact Instruction Manual

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

Instruction Manual. Ex-Time 40 / 50

INDUCTIVE CONDUCTIVITY SENSOR. Instruction Manual. Bürkert 2001 Subject to technical change without notice

HANGKAI GROUP HOYMILES MICRO-INVERTER MI-250

Electrically Released Brakes ERS VAR11-01 FT = 4100 N

Visit us at

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Operating Instructions. bluesmart Active

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

DIAPHRAGM LIQUID PUMP NF 1.30

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Operating instructions. sonnenprotect for operators. KD-337 Part no Version X00.

Transcription:

Handheld calibration tool / Handheld cleaning tool Tragbares Kalibrierwerkzeug / Tragbares Reinigungswerkzeug Outil d'étalonnage portatif / Outil de nettoyage portatif Operating Instructions Bedienungsanleitung Manuel d utilisation

We reserve the right to make technical changes without notice. Technische Änderungen vorbehalten. Sous réserve de modifications techniques. Bürkert SAS, 2017 Operating Instructions 1704/00_EU-ML_00569085 / Original DE

Table of contents 1 OPERATING INSTRUCTIONS... 4 1.1 Definition of terms... 4 1.2 Symbols used... 4 2 INTENDED USE... 5 3 BASIC SAFETY INFORMATION... 5 4 GENERAL INFORMATION... 6 4.1 Contact address... 6 4.2 Warranty... 6 4.3 Information on the Internet... 6 9 OPERATION AND FUNCTION... 10 9.1 Safety instructions... 10 9.2 Calibrating the sensor cube... 10 9.3 Cleaning the sensor cube... 11 10 MAINTENANCE AND TROUBLESHOOTING... 13 10.1 Changing the batteries... 13 10.2 Troubleshooting... 13 11 SPARE PARTS... 13 12 TRANSPORT, STORAGE, DISPOSAL... 14 5 PRODUCT DESIGN... 7 6 TECHNICAL DATA... 7 6.1 Conformity... 7 6.2 Standards... 7 6.3 Conditions of use... 7 6.4 Mechanical data... 8 6.5 Electrical data... 8 6.6 Rating plate... 8 7 CALIBRATION TOOL ELECTRICAL CONNECTION... 9 8 COMMISSIONING... 9 8.1 Safety instructions... 9 8.2 Inserting batteries... 9 3

Operating instructions 1 OPERATING INSTRUCTIONS The Operating Instructions describe the entire life cycle of the product. These instructions should be kept within easy access at the place of use. Important safety information! Read these Operating Instructions carefully. Pay particular attention to the safety information, intended use and operating conditions. Persons working with the product must read and understand these Operating Instructions. 1.1 Definition of terms In these Operating Instructions, the term "product" refers to the following versions of tool type MZ15: Portable calibration tool for sensor cubes of the type 8905 on-line analysis system Portable cleaning tool for sensor cubes of the type 8905 on-line analysis system In these Operating Instructions, the term "system" refers to the type 8905 on-line analysis system 1.2 Symbols used DANGER Warns against an imminent danger. If ignored, death or serious injury will result. WARNING Warns against a potentially dangerous situation. If ignored, serious injury or death may result. CAUTION Warns of possible danger. If ignored, substantial or minor injuries may result. NOTICE Warns against material damage. Important advice and recommendations. Refers to information in the Operating Instructions or in other documents. Menu Indicates an instruction to avoid a hazard. Indicates a procedure that must be carried out. Indicates a result. Representation for software interface texts. 4

Intended use 2 INTENDED USE Use of this product that does not comply with the instructions could present risks to people and the environment. The product in the calibration tool version is designed for the calibration of individual sensor cubes MS01, MS03 and MS04. The product in the cleaning tool version is designed for cleaning the fluidic circuit of individual sensor cubes MS01, MS03, MS04 and MS05. The product must be used in compliance with the characteristics, operating conditions and conditions of use. This information can be found in the contract documents, the operating instructions and on the rating plate. The product: do not use in an outdoor area. use only with calibration or cleaning solutions approved and specified by Bürkert. use only in conjunction with external devices or components recommended by Bürkert. use in a frost-protected location. protect from electromagnetic interference. operate only in perfect working order and ensure appropriate storage, transport, installation and control. use only for its intended purpose. 3 BASIC SAFETY INFORMATION These safety instructions do not take account of any hazards and events arising during installation, operation and maintenance. The operator is responsible for ensuring that local safety regulations in relation to staff are respected. Danger due to the nature of the operating agents. Observe the rules in force concerning accident prevention and safety and which relate to the use of hazardous liquids. Observe the information on the safety data sheet for the cleaning solution. The relevant data sheet can be found at the address given on the bottom of the bottle. Wear personal protective equipment when working with cleaning solutions. Dispose of any waste in compliance with the information provided in the safety data sheet. Local regulations regarding disposal shall be observed. Various dangerous situations. To avoid personal injury take care: to use the product only if in perfect working order and in compliance with the instructions provided in these Operating Instructions. not to use this product in potentially explosive areas. 5

General information not to make any modifications to the product and not to subject it to mechanical loads. to ensure that only trained personnel perform installation and maintenance work. to observe best industry practice. NOTICE Only operate the product with 4 LR6 AA batteries. NOTICE Elements and components sensitive to electrostatic discharges. This product contains electronic components sensitive to electrostatic discharges They may be damaged if they are touched by an electrostatically charged person or object. In the worst case, these components will become defective immediately or will fail when energized. Comply with the requirements according to EN 61340-5-1 in order to eliminate or minimize the possibility of damage through sudden electrostatic discharge. Do not touch any of the live electrical components. 4 GENERAL INFORMATION 4.1 Contact address To contact the manufacturer of the product, use the following address: Bürkert SAS Rue du Giessen BP 21 F-67220 TRIEMBACH-AU-VAL The addresses of our international branches can be found on the Internet at: www.burkert.com 4.2 Warranty The warranty is conditional on compliant use of the product in observance of the operating conditions specified in this manual. 4.3 Information on the Internet You can find the Operating Instructions and technical data sheets for Bürkert products at: www.burkert.com 6

Product design 5 PRODUCT DESIGN Bottle holder with 2 integrated check valves Fig. 1: Bottle with calibration solution (not included in the delivery) Bottle for waste (not included in the delivery) Calibration tool description Bottle holder Bottle with cleaning solution (not included in the delivery) M12 plug Backplane Actuator button Battery compartment cover Backplane Actuator button Battery compartment cover 6 TECHNICAL DATA The following values are specified on the rating plate: Operating voltage/current consumption IP rating according to EN 60529/IEC 60529 Fluid temperature range Pressure range 6.1 Conformity The product complies with EU directives according to the EU declaration of conformity (if applicable). 6.2 Standards The standards used to demonstrate conformity with the Directives can be consulted in the EU type examination certificate and/or the EU declaration of conformity (if applicable). 6.3 Conditions of use WARNING Risk of injury from malfunction due to outdoor use. Do not use the product in outdoor areas and avoid heat sources that could result in the permissible temperature range being exceeded. Fig. 2: Cleaning tool description 7

Technical data Ambient temperature Air humidity IP rating according to EN 60529 6.4 Mechanical data +3...+40 C < 80%, without condensation IP20 Dimensions and weight: refer to the relevant data sheet at www.burkert.com Part Housing Screws Rating plate M12 plug Parts in contact with fluid Seal Further materials Fig. 3: Product materials 6.5 Electrical data Power supply Material ABS Stainless steel, passivated steel metallized polyester Zn, CuZn, Au, PA EPDM, not replaceable PA, POM, PPS, Silicone 4 AA LR6 batteries, 6 V total 6.6 Rating plate 9 1. Product type F-67220 Triembach 8 1 MZ15 - Calibration device Supply: 6V 4A IP20 PN01 Temperature: 3...40 C 00568805 S/N 1000 2. Operating voltage (from batteries) 3. Maximum liquid pressure 4. Liquid temperature range 5. Serial number 6. Manufacturing code 7. Order code 8. Conformity marking 9. IP rating according to EN 60529 Fig. 4: 7 Rating plate description W42MS Made in France 2 3 4 5 6 8

Calibration tool electrical connection 7 CALIBRATION TOOL ELECTRICAL CONNECTION Pin number Signal 1 CAN_SHIELD 2 Not assigned 3 Not assigned 4 CAN_H 5 CAN_L 2 1 3 Tab. 1: Pin assignment M12 device plug Connect M12 plug of the calibration tool, with a büs cable available as an accessory, to the last M12 socket of the system. 4 5 8 COMMISSIONING 8.1 Safety instructions WARNING Danger of injury from improper operation. Prior to commissioning, it must be ensured that operating personnel have read and fully understand the contents of the Operating Instructions. Pay particular attention to the safety recommendations and intended use. The product or system may only be commissioned by trained staff. 8.2 Inserting batteries Before commissioning, insert 4 AA LR6 batteries in the battery compartment of the product, as shown in Fig. 5. 1. Press on the side access and remove the housing cover. 9

Operation and function 2. Pull out the battery compartment. 9 OPERATION AND FUNCTION 9.1 Safety instructions WARNING 3. Open the battery compartment. Danger due to improper operation. Operating personnel must have read and understand the content of the Operating Instructions. Pay particular attention to the safety recommendations and intended use. The product or system must only be operated by adequately trained staff. 9.2 Calibrating the sensor cube 4. Insert batteries. Ensure correct positioning. 5. Push the closed battery compartment into the housing (see figure). 6. Replace housing cover. The appropriate Operating Instructions are required for calibrating a sensor cube. The sensor cube Operating Instructions can be downloaded from www.burkert.com. 1. Prepare one or two calibration solutions according to the sensor cube to be calibrated. See chap. 11 Spare parts. 2. Prepare an empty waste bottle. See chap. 11 Spare parts. 3. Screw the empty waste bottle in the correct position of the bottle holder. 4. Screw the bottle with the first calibration solution in the correct position of the bottle holder. Fig. 5: Inserting batteries in the product 10

Operation and function The calibration of the sensor cube is controlled via the system display or using Bürkert Communicator Software. Connect the calibration tool to the system or the Bürkert Communicator Software using büs. See chap. 7 Calibration tool electrical connection. 5. Select the sensor cube to be calibrated on the system display or in the Bürkert Communicator: the LED of the sensor cube flashes. 6. Remove the sensor cube from the backplane of the system and fit and lock it on the backplane of the product. Keep the product upright during calibration: -- so that the fluid flows correctly through the sensor cube; -- and so that the check valves function correctly. 7. Reselect the sensor cube in the system display or in Bürkert Communicator: the LED of the sensor cube flashes. 8. Call up the calibration wizard in the maintenance view of the sensor. 9. Refer to the subsequent steps in the sensor cube Operating Instructions. 10. After calibrating, remove the sensor cube from the backplane of the product and insert and lock it on the backplane of the system. 9.3 Cleaning the sensor cube CAUTION Danger due to the nature of the operating agents. Observe the rules in force concerning accident prevention and safety and which relate to the use of hazardous liquids. Observe the information on the safety data sheet for the cleaning solution. The relevant data sheet can be found at the address given on the bottom of the bottle. Wear personal protective equipment when working with cleaning solutions. Dispose of any waste in compliance with the information provided in the safety data sheet. Local regulations regarding disposal shall be observed. Sensor fluid system cleaning takes place in two steps: 1. Dissolve the contaminants with a cleaning solution. 2. Flush the cleaning solution with a flushing solution. 9.3.1 Dissolving contaminants 1. Prepare a cleaning solution according to the type of contaminant. See chap. 11 Spare parts. The cleaning solution is pumped in the circuit and thinned by impurities. Use a new cleaning solution every five cleanings. 2. Screw the bottle with the cleaning solution onto the product's bottle holder. 3. Remove the sensor cube from the backplane of the system and fit and lock it on the backplane of the product. 11

Operation and function Due to the mounting position of the sensor cube, always keep the product upright during cleaning. 4. Press the actuator button in order to allow the cleaning solution to flow through the fluid system of the sensor cube. The pump will operate so long as the button is pressed. Adjust the pumping duration according to the degree of contamination of the sensor cube fluid system: see Tab. 2. Degree of contamination Pumping duration (s) Light contamination 10 Average contamination 20 Heavy contamination 60 Tab. 2: Recommended pumping durations according to degree of contamination 5. Remove the sensor cube from the backplane of the product and lay flat. 6. Allow the cleaning solution to soak in for a time dependent on the degree of contamination. See Tab. 3. Degree of contamination Soaking time (min) Light contamination 5 Average contamination 10 Heavy contamination 15 Tab. 3: Recommended soaking time depending on degree of contamination 7. After the soaking time, ensure that no cleaning solution remains in the sensor cube. See chap. 9.3.2. 9.3.2 Flush the cleaning solution 1. Prepare a flushing solution. See chap. 11 Spare parts. The flushing solution is pumped in the circuit. Use a new flushing solution every five flushings. 2. Screw the bottle with the flushing solution in place of the cleaning solution on the product's bottle holder. 3. Fit and lock the sensor cube on the backplane of the product. 4. Always keep the product upright during flushing. 5. Operate the pump for at least 10 s; press the actuator button for 10, 20 or 30 s according to the degree of contamination. 12

Maintenance and troubleshooting 10 MAINTENANCE AND TROUBLESHOOTING 10.1 Changing the batteries NOTICE Environmental damage caused by incorrect disposal of batteries. Observe local regulations when disposing of batteries. To change the batteries, follow the procedure in chapter 8.2. 10.2 Troubleshooting A warning or error may be generated during calibration. To resolve this, refer to the Operating Instructions for the calibrated sensor cube, at www.burkert.com. 11 SPARE PARTS CAUTION Risk of injury and/or damage caused by the use of nonoriginal parts. Non-original accessories and unsuitable replacement parts can cause injuries and damage the product and the surrounding area. Use only original accessories and spare parts from Bürkert. Accessories Cleaning solution Order code Cleaning solution, acid, 250 ml 807478 Cleaning solution, alkaline, 250 ml 807486 Calibration solution Buffer solution ph 5.00 (20 C), 50 ml 806698 Buffer solution ph 7.00 (20 C), 50 ml 806699 Buffer solution ph 9.00 (20 C), 50 ml 806700 Redoxpotential 475 mv, 50 ml 807045 Conductivity 5 ms/cm, 50 ml 807199 Flushing solution Flushing solution, 50 ml 806709 Flushing solution, 250 ml 806710 13

Transport, storage, disposal Accessories Electrical accessories Order code büs cable, plug/socket, straight, 1 m 772404 büs cable, plug/socket, straight, 3 m 772405 büs cable, plug/socket, straight, 5 m 772406 büs Y-distributor 772420 12 TRANSPORT, STORAGE, DISPOSAL NOTICE Inadequately protected products may be damaged during transport. Transport the product in shock-resistant packaging and away from humidity and dirt. Comply with the permissible storage temperature. Poor storage can damage the product. Store the product in a dry place away from dust. Before storage, pump any cleaning solution out of hoses. Storage temperature -40 +55 C. Environmental damage due to product parts contaminated by fluids. When disposing of cleaning solutions, follow the instructions on the safety data sheet. The safety data sheet can be found at http://sds-id.com/200124-7 Dispose of the product and its packaging in an environmentally friendly manner. Comply with applicable environmental and disposal regulations. Environmental damage caused by incorrect disposal of batteries. Observe local regulations when disposing of batteries. 14

www.burkert.com