Network Zone System Part Numbers: Z23N-***** Z23R-****

Similar documents
Universal Network Zone System Part Numbers: Z23U-****

Network Zone System. Part Numbers: Z22N-****** Z22R-****

Z22C-** Preconfigured Network Zone System

Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF and ZDF

Opticom Rack Mount Fiber Enclosures

Instructions for Wire Mesh Pulling Grips on Outside Plant and Indoor/Outdoor Fiber Optic Cable Best Practices

Panduit PreConfigured ZDF48-RA Industrial Distribution Frame (IDF) Installation Instructions

Company Switch Installation Instructions and User Manual

Fiber Optic Above-Ground) Cross-Connect Enclosure (ACE) Model ACE-200DS Installation Guide)

PanView iq (PViQ) Fiber Tray

Power Connection Kit Installation Instructions. Terminator DP-M for use with TEK and HTEK series constant watt heating cables

Pneumatic Isolation Module

Galaxy VM. Battery Breaker Box Installation 09/

S Fault Indicators. S.T.A.R. Type TPR Faulted Circuit Indicator Installation Instructions. Contents INSTALLATION PROCEDURES

INSTRUCTIONS. Power Panel. Installation Instructions

Effective March 2015 Supersedes S August 2012

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal

COOPER POWER SERIES. 600 A 15, 25, and 35 kv Class Cleer Loadbreak Bushing Insert Installation Instructions. Loadbreak/Deadbreak Connectors MN650016EN

Cellwatch Electrical Installation

Application Specification Circular Plastic Connector (CPC) Series 45 System 05 AUG 14 Rev D

Installation Instructions for Lifeline MC Cable Splice Using Ceramic Standoffs

COOPER POWER SERIES. 200 A Fused Loadbreak Elbow Connector Replacement Fuse Installation Instructions. Fusing Equipment MN132021EN

SAVE THESE INSTRUCTIONS

Instructions for Use - Opt-X 1000i Enclosure

INSTALLATION INSTRUCTIONS

Power Connection Kit Installation Instructions. Terminator ZP-M for use with TEK and HTEK series constant watt heating cables

Fiber Splice Panel Rack Mount User Manual

accessory guide Indoor AP Accessories Compatible Products Description Picture Kit Contents

Terminator DL-S for use with BSX *, HTSX, KSX self-regulating, HPT power-limiting, and FP constant watt heating cables

37SCENE 46SCENE 79SCENE

COOPER POWER SERIES. S.T.A.R. type LVR faulted circuit indicator installation instructions. Fault Indicators MN320005EN

GTX UNIT SUBSTATION Installation, Maintenance & Operation Manual

INLET DUCT FOR CISCO 6880 Part Number(s) DIRLC25S23W

8400 Series Fiber Distribution System

Installation Instructions for Lifeline MC: Cable Splice Using Ceramic Standoffs Technical Information Sheet #402

INSTALL INSTRUCTIONS DC C-EV. Installation Instructions: DC C-EV.

IMPORTANT SAFETY INSTRUCTIONS

accqpulse Velocity Profiler Sensor Installation Guide

S Voltage Regulators GENERAL. Contents. Acceptance and Initial Inspection. Handling and Storage. Standards

Dry Contact Closure Interface

FIBER CONNECTOR SAFETY WARNINGS

CS Fiber Optic Splice Case. Instruction

COOPER POWER SERIES. Screened Separable Connectors MN650023EN. Effective October 2016 Supersedes March 2012 (IS )

COOPER POWER SERIES. KA662R tank-lifting windlass assembly and installation instructions. Recloser Mountings MN280071EN

EPLX and D2LX lighting panelboards Installation & maintenance information IF 1813 APPLICATION D2LX/EPLX IF SHEET TABLE OF CONTENTS WEIGHTS

COOPER POWER SERIES. Screened Separable Connectors MN650024EN. Effective October 2016 Supersedes March 2012 (IS )

Effective November 2016 Supersedes February 2012 (S )

Terminator. DP Power Connection Kit INSTALLATION PROCEDURES

COOPER POWER SERIES. High-voltage primary bushings installation instructions. OEM Equipment MN800008EN

SPECIAL SPECIFICATION 1788 Surveillance Cabinet

COYOTE STP (Service Termination Point)

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals

Installation Instructions For Motor Control Center (MCC) Units

EPIC CIRCON M23 Series

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

Singular and rows of racks in steel and stainless steel, PC racks. Server and distribution rack systems, enclosures and housings

SYSTIMAX 360 ipatch InstaPATCH Fiber Shelf Instructions

SynergEX Panelboards for Hazardous Locations

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Replacement of 600-Ampere Bushing and 200-Ampere Bushing-Well Adapters

COOPER POWER SERIES. Current-Limiting Type NXC (C-Rated) Fuse Installation Instructions. Fusing Equipment MN132014EN

Installation Manual. AutoSteer. Gleaner Combine. AutoGuide 2 Steer Ready. Supported Models A66 A76 R66 R76 S67 S77 PN: A

ComfortPoint Programmable Lon, VAV/Unitary Controllers

COOPER POWER SERIES. Quick Connect Assembly (QCA) Retrofit Kit, General Electric Installation Instructions. Voltage Regulators MN225075EN

Type 2 Arc Resistant WL Low Voltage Metal-Enclosed Switchgear

Instruction and Installation Guide

Terminator DP/FAK-2 and FAK-2L. Elbow Splice Kit for Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES

High-voltage primary bushings installation instructions

COYOTE 28" GLC (Ground Level Closure) Complete Assembly Installation

SPECIAL SPECIFICATION 6894 Communication Cabinet

Effective November 2016 Supersedes September 1998 (S )

INSTALLATION INSTRUCTIONS

Installation Manual & Warranty

INSTALLATION INSTRUCTIONS

LPC Series Fiber Panel 12/24 Fiber Rack-Mount Enclosure Installation Instructions

INLET DUCT FOR CISCO 9513 SWITCH Part Number: DIBBC2314S21W

INSTALLATION INSTRUCTIONS


DIGITAL PHYSICIAN Waist-High Scale Models 8430, 8431 & 8437 Operating Instructions

HP BladeSystem c7000 Carrier-Grade Options Installation Guide

Effective June 2016 New Issue

Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application.

ZP-XP Power Connection Kit. Terminator. The Heat Tracing Specialists INSTALLATION PROCEDURES

INSTALLATION INSTRUCTIONS

COOPER POWER SERIES. 600 A 15/25 kv class BOL-T and separable splice connector assembly installation instructions

INSTALLATION INSTRUCTIONS

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals

COYOTE STP (Service Termination Point)

Fiber Connector Shelf (CCS)

General Specifications for Lighthouse Power Pedestal

Access your fiber assemblies in the front of the enclosure to your fiber splices via a rear door without disturbing the fiber.

Speed Sensor. Inputs: Safety Information. Outputs. Wiring Diagram. Electrical Data: NOTICE

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

LED IMPORTANT SAFETY INSTRUCTIONS

Space Optimization For Control Panels

INSTALLATION MANUAL. Melink Corporation (513) Revision

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

Effective May 2017 Supersedes January 2003 (S )

COOPER POWER SERIES. RTE EL-BAY-O-NET FUSE Re-Fusing Instructions. Fusing Equipment MN132024EN

Transcription:

Network Zone System Part Numbers: Z23N-***** Z23R-**** Page 1 of 14

TABLE OF CONTENTS Overview of Products Specs / Tools Needed Safety Information / Warnings Wall Mounting Bracket Installation Wall Mounting Removable Gland Plate Reversible Door Integrated Layout Page 3 Page 4 Page 5 Page 6 Page 7 Page 7 Page 8 Page 9 Recommended Installation Instructions for: Terminal Block Removal Switch Installation Cage Removal Power Entry Uplink Entry Downlink Entry Connect Zone SYS To Uplink Patch Cord Routing Page 10 Page 11 Page 12 Page 12 Page 12 Page 12 Page 13 Page 14 Page 2 of 14

A B C D E M L K J I H G F Network Zone System configurations include an enclosure with required connectivity and cable management, internal factory-connected wiring and includes partner equipment as specified on the Field Wiring Diagram supplied inside each unit. Additional equipment may include one or more of the following DIN-Rail mountable items: A). Industrial automation switch* B). Industrial automation switch expansion module* C). Management slack L-rings. D). Strain relief bar E). Patch panel F). Panduit UPS (uninterruptable power supply) G). LSM (load sense module) H). Power supplies I). Lockout Terminal Contact Blocks J). Field-wiring terminal for customer-supplied power input wiring K). Ground bar terminal for customer-supplied ground L). Fiber slack spool M). Fiber Patch Box *Switch may be included or customer supplied. Page 3 of 14

Network Zone System Specifications Standards (May Include) UL 508A IEC 60950-1 IEC 60950-22 EN55022 EN55024 VCCI Enclosure Rating (May Include) Environment Installation Dimensions Weight FCC, Part 15, Subpart B ICES-003 UL Type 4/12 and IP66 (IEC 60529), NEMA 4X available All electrical components rated for Class 1, Division 2 environments 40 C ambient outside of enclosure or 60 C maximum within enclosure at up to 95% (non-condensing) humidity Wall mount with optional outside-mount flange Height Width Depth 36.0 (914 mm) 110 lbs. (49.9 kg) 24.0 (610 mm) 11.7 (297 mm) **Use Field Wiring Diagram for the Electrical Rating and Maximum Over-current Protection.** **For customer supplied switch use manufacture instructions for installing and wiring.** Tools and supplies needed to complete install of Integrated Zone System (not included): Fiber-optic trunk cable: FSPD504 or similar LC Fiber-optic connectors: FLCDMCXAQY or similar Fiber-optic termination tools: OptiCam termination kit or similar Category 6 copper cable for downlinks: PUR6504BU-UY or similar Wire cutters for copper cable termination Power wiring: #14 AWG recommended Rigid conduit for power and copper downlink cables Tools to cut enclosure sidewalls: Greenlee punch or similar External Power Disconnect 5/16 bolts for wall mounting of steel enclosure #6 AWG Infrastructure ground cable: RGEJ660PF or similar Screw drivers: #2 Phillips, 3/16, and 2.5mm flathead 3/8" bolts for wall mounting of stainless steel enclosure 3/8" socket or box wrench ground bar Switch (Switch ready zone only) Page 4 of 14

SAFETY INFORMATION The information and instructions contained in this document are not intended to be utilized as a substitute for proper training and experience in the safe installation and operation of product. Prior to installation, it is the Buyer s responsibility to consult with the appropriate local Authority Having Jurisdiction (AHJ) for all applicable codes, permits, regulations and standards. This product, including any equipment that may be installed inside, should only be installed and serviced by a licensed electrical contractor, or competent technician, that meets the following qualifications; Is thoroughly familiar with this product and the instructions for installation and operation Is trained (accredited) in industry-accepted safe operating practices and procedures regarding identification and mitigation of high- and low- voltage hazards and situations. Is trained to identify and install appropriately-sized Branch Circuit Disconnect(s) with appropriately-sized Branch-Circuit Protective Rating and Short-Circuit Current Rating (SCCR), before connecting Panduit product to the branch circuit. Is trained and authorized to energize, de-energize, clear and ground power distribution equipment. Is trained in the care and use of PPE (personal protective equipment) including, but not limited to; arc-flash protective clothing, safety glasses, face shield, hard hat, gloves, and non-conductive tools (clamp stick, hot stick, etc WARNING Be sure wall is capable of supporting cabinet and equipment. DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITIES The practices contained herein are designed as a guide for use by persons having technical skill at their own discretion and risk. Panduit does not guarantee any favorable results or assume any liability in connection with these instructions. Local, State, Federal, and Industry Codes and Regulations, as well as manufacturers requirements, must be consulted before proceeding with any project. Panduit Corp. makes no representations of nor assumes any responsibility for the accuracy or completeness set forth herein. Panduit disclaims any liability arising from any information contained herein or for the absence of same. Page 5 of 14

Wall Mounting Bracket Installation Note: The enclosure may be mounted to the wall without the mounting brackets Latch Tool Wall Mounting Brackets Step 1: Turn enclosure on its side with the locks orientated towards the top. Using Latch Tool, turn both locks towards each other to open door. Step 2: Install Wall Mounting Brackets into back of the enclosure aligning threaded studs on brackets to holes located in back of the enclosure. Be sure obround mounting holes on the wall mounting bracket align outward. Step 3: Secure wall mounting brackets using the supplied sealing washers use (1) per threaded stud. Torque spec: Steel Enclosure: 5/16" washers = 30 in-lbs Stainless Steel Enclosure: 3/8" washers = 40 in-lbs Step 4: Close Door. Using Latch Tool, turn both locks to secure the door. If Mounting Flanges are not used: For Steel Enclosure: Use 5/16" Sealing Washer (supplied) and a 5/16" Bolt (not supplied) in the locations where the threaded studs in the mounting flanges would go to mount enclosure directly to wall. For Stainless Steel Enclosure: Use 3/8" Sealing Washer (supplied) and a 3/8" Bolt (not supplied) in the locations where the threaded studs in the mounting flanges would go to mount enclosure directly to wall. Step 1 Step 2 Sealing Washer Hex Nut Detail View 4 Places Step 3 Screw (not provided) Washer (provided) Mounting Flanges not used (4 places) Page 6 of 14

Panduit Corp. 2015 INSTALLATION INSTRUCTIONS Wall Mounting Enclosure may be mounted on any wall utilizing Unistrut or by drilling directly into any concrete wall. There are two mounting hole locations on the top flange and two locations at the bottom flange. 19.25-22.0 22.5 Step 1: Drill holes 19.25"-22" apart horizontally and 38" apart vertically. Step 2: Mount the enlosure with the locks to the right and secure. If mounting flanges are not used: The holes in the wall will be 22.5" apart horizontally and 34.5" apart vertically. 38 34.5 Hole Locations for Wall Mounting Dimensions for Wall Mounting without Flanges Removable Gland Plate Remove the gland plate prior to drilling holes for conduit entry. Accommodations for incoming conduit have been supplied on the enclosure. This will help prevent metal shavings from entering the electronic components in the enclosure. Recommend installation of IP66 rated conduit fittings that comply with the IEC codes that are applicable to the intended application. The Gland Plate, located on bottom of the enclosure, is removable for machining to accept bulkhead connectors or compression fittings. To remove gland plate,(12) screws and (12) flat washers attached to the threaded studs of the gland plate and remove plate from the enclosure.when reinstalling the gland plate, ensure the nuts are tightened until the gland plate flanges make contact with the enclosure surface. Gland Plate Page 7 of 14

Reversible Door The enclosure comes with the door opening to the left. The door may be reversed to open to the right. Step 1: Remove pins from the door hinges. Step 2: Remove screws and door hinges Step 3: New Hole locations will have to be drilled or punched out. Reinstall hinges and screws on opposite side. Step 4: Turn door 180 degrees and mount to the opposite side of the enclosure. Insert the same pins to secure the door. Step 1 Step 2 Step 3 Torque 33 in-lbs. Add silicone to bolts (6x) (Not Supplied) Step 4 Page 8 of 14

Panduit Corp. 2015 INSTALLATION INSTRUCTIONS Strain Relief Bar Integrated Layout Fiber Surface Mount Box Fiber Patch Cord Slack Spool Cable Management L- rings mounted to the side accessory panel and top slack plate May include Stratix din rail mounted switches with expansion modules. Patch Field Industrial Switch Power Supplies Ground Bar May include Panduit Uninterrupted Power Supply Page 9 of 14

Panduit Corp. 2015 INSTALLATION INSTRUCTIONS Terminal Block Removal Z23R-**** Only 1 Remove wiring from terminal blocks (2 locations) 2 Remove terminal blocks (2 locations) Terminal Block Removal 1. Remove wiring from terminal blocks 2. Remove terminal blocks *Note: Do not apply power prior to terminal block removal on the switch ready network zone system. Page 10 of 14

Panduit Corp. 2015 INSTALLATION INSTRUCTIONS Switch Installation Z23R-**** Only 1 Install Switch 2 Refer to switch manufacturer for proper wiring installation Switch Installation 1. Install switch 2. Wire switch - Refer to switch manufacturer s instructions for proper wiring technique. *Note: Install switch before applying power to switch ready network zone system. Page 11 of 14

Cage Removal Recommended Installation Instructions for Power Entry Remove(3) #10-32 screws Remove plug in gland plate and replace with conduit fitting. Recommend installation of IP66 rated conduit fittings that comply with the IEC codes that are applicable to the intended application. Install power wiring according to the Field Wiring Diagram. Connect Infrastructural ground to ground bar Power Conduit Entry Uplink cable (fiber shown) spooled in the surface mount box Recommended Installation Instructions for Uplink Entry Recommended Installation Instructions for Downlink Entry Service loop formed behind the patch panel or on top of the cable management L rings. Uplink Cable Conduit Entry See Page "11" Connection to SYS Uplink Ports Downlink Cable Conduit Entry Page 12 of 14

Connecting to Zone System Uplink Ports Armored Fiber Uplink Cable Fiber Surface Mount Box LC to LC Patch Cords Fiber Spool Assembly The Zone Enclosure can have either a fiber or copper uplink. Copper uplinks are limited to 330ft (100m) distance and relatively noise free environments. It is recommended to use a structured cabling approach, terminating the horizontal cable to an RJ-45 jack or LC connector and adapter. Then using factory made patch cords to connect to the switch. Copper Uplink There are 2 copper RJ-45 uplink ports that can be configured for a star, ring, or linear topology. The copper horizontal cable can be brought straight into the enclosure via conduit. The uplink copper horizontal cables should be terminated to the Patch Panel (48 ports) or single port din mount adaptor.may be used if patch box or patch panel are full. The provided Panduit Patch Cords connect the horizontal cable jack to the Stratix. Fiber Uplink The Stratix has 2 SFP uplink ports that can accommodate 2 Fiber SFP transceiver modules. Either Multi-mode or Single Mode SFPs can be used. Fiber uplinks can be brought into the zone enclosure via conduit, using fiber distribution cable or Panduit armored fiber, DCF, or PCF, as needed. The fiber strands are terminated inside the provided Fiber Surface Mount Box (CBXF6BL-AY). The Fiber Surface Mount Box features internal slack management along with provided Panduit LC adapters (FADJAQLCZBL). Fibers will be terminated to LC connectors (Panduit Opticam FLCDMCXAQY recommended, not included). For instructions on Panduit LC termination, see instruction sheet LC OptiCam Connector : FS014 available on at www.panduit.com. When armored fiber cable is used, the outer casing is connected to the enclosure using Panduit s Armored Cable Grounding Kit (See www.panduit.com for the applicable part no.) The inner distribution cable is exposed and terminated in the same manner as other distribution cable. If a metal clad armor casing is used, it will need to be grounded. See T-PMPI-292-PC for armor cable grounding details. From the Fiber Surface Mount Box, the provided LC to LC duplex patch cords (FZE10-10M1) are used to connect from the fiber adapter modules to the SFP transceiver module on the switch. Fiber patch cord slack is stored in the included fiber spool.it is important to wind the fiber patch cord slack on the spool to prevent sharp bends or snag that can degrade transmission. Page 13 of 14

Recommended Installation Instructions for Patch Cord Routing Patch cords supported by the strain relief bar and L-ring managers, routed from the switch to the patch panel Route fiber cord from surface mount box to switch. Route fiber patch cord slack on the fiber spool in between box and switch. For Instructions in Local Languages and Technical Support: www.panduit.com Page 14 of 14 E-mail: tp-csdebt@panduit.com Fax: (800)777-3300