Network Zone System. Part Numbers: Z22N-****** Z22R-****

Similar documents
Network Zone System Part Numbers: Z23N-***** Z23R-****

Universal Network Zone System Part Numbers: Z23U-****

Z22C-** Preconfigured Network Zone System

Opticom Rack Mount Fiber Enclosures

Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF and ZDF

Panduit PreConfigured ZDF48-RA Industrial Distribution Frame (IDF) Installation Instructions

Instructions for Wire Mesh Pulling Grips on Outside Plant and Indoor/Outdoor Fiber Optic Cable Best Practices

PanView iq (PViQ) Fiber Tray

Fiber Optic Above-Ground) Cross-Connect Enclosure (ACE) Model ACE-200DS Installation Guide)

Pneumatic Isolation Module

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal

Installation Instructions for Lifeline MC Cable Splice Using Ceramic Standoffs

Installation Manual. AutoSteer. Gleaner Combine. AutoGuide 2 Steer Ready. Supported Models A66 A76 R66 R76 S67 S77 PN: A

INSTRUCTIONS. Power Panel. Installation Instructions

Installation Instructions for Lifeline MC: Cable Splice Using Ceramic Standoffs Technical Information Sheet #402

INLET DUCT FOR CISCO 6880 Part Number(s) DIRLC25S23W

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

Instructions for Use - Opt-X 1000i Enclosure

8400 Series Fiber Distribution System

Application Specification Circular Plastic Connector (CPC) Series 45 System 05 AUG 14 Rev D


SYSTIMAX 360 ipatch InstaPATCH Fiber Shelf Instructions

Singular and rows of racks in steel and stainless steel, PC racks. Server and distribution rack systems, enclosures and housings

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals

INSTALL INSTRUCTIONS DC C-EV. Installation Instructions: DC C-EV.

Cellwatch Electrical Installation

INSTALLATION INSTRUCTIONS

Turbo-House Air Inlet Installation & Operator s Instruction Manual

accqpulse Velocity Profiler Sensor Installation Guide

Glass Reinforced Polyester Enclosures

CS Fiber Optic Splice Case. Instruction

Fiber Splice Panel Rack Mount User Manual

Mini USB and USB 2.0-IP67 Connector System

HP BladeSystem c7000 Carrier-Grade Options Installation Guide

DIGITAL PHYSICIAN Waist-High Scale Models 8430, 8431 & 8437 Operating Instructions

INSTALLATION INSTRUCTIONS

Operating Instructions

Dry Contact Closure Interface

OFS 400A FIBER OPTIC INTERCONNECT Instruction Sheet UNIT (FOIU) Comcode INSTALLATION

General Specifications for Lighthouse Power Pedestal

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals

EPIC CIRCON M23 Series

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

INSTALLATION INSTRUCTIONS

Output signal active note. Measuring range rel. pressure. Electrical Data Power supply DC V, ±10%, 1.1 W

Speed Sensor. Inputs: Safety Information. Outputs. Wiring Diagram. Electrical Data: NOTICE

SynergEX Panelboards for Hazardous Locations

Part Number: 10GX F/UTP CMR PATCH CORDS 10GX F/UTP CMR Patch Cords

INSTRUCTION SHEET. Installation Instructions for Mercmaster LED Luminaire. Applications. Agency Ratings. Product Safety

LPC Series Fiber Panel 12/24 Fiber Rack-Mount Enclosure Installation Instructions

LCU DX Efficient cooling with no loss of space

accessory guide Indoor AP Accessories Compatible Products Description Picture Kit Contents

Installation Instructions: HYPERION R-Lite SYSTEM

Sentinel Field Satellite Controller

PVM 220 Installation Guide

TE-6100 Series Temperature Sensors and Completed Sensor/Hardware Assemblies

FIBER CONNECTOR SAFETY WARNINGS

Automatic Roof Hatch Opener

Chapter 3. Installing Equipment

International approvals.

Differential Pressure Sensors

SG-B1 SERIES / SG-A1 SERIES

Lighting Control Unit Installation Instructions

INSTALLATION INSTRUCTIONS

PVM 220 Installation Guide

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

EPLX and D2LX lighting panelboards Installation & maintenance information IF 1813 APPLICATION D2LX/EPLX IF SHEET TABLE OF CONTENTS WEIGHTS

Standard Interlock Safety Switches

ComfortPoint Programmable Lon, VAV/Unitary Controllers

COYOTE STP (Service Termination Point)

SYSTIMAX G2 4U Fixed Rear Access Combination Shelf Instructions

Power Connection Kit Installation Instructions. Terminator DP-M for use with TEK and HTEK series constant watt heating cables

FL2000 Termination/Splice Panels User Manual

An Investment in Plant Floor Safety. 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches

VERTIV XTE 401 SERIES. Ordering Guide

UV8 & UV90 SERIES INSTALLATION INSTRUCTIONS

Differential Pressure Sensors

ENYSTAR Load Centers up to 250 A

Directory chapter 08. InduCom Robust and EMI protected D-Sub interfaces

Duct System for a Server or Switch Cabinet Mounted Cisco 4900M (CNLTD21B2)

650 Series Cargo Van Lift Mounting Instructions Ford Transit (Standard Roof) 2015-Present

JBR MAZDASPEED

Installation Instructions: ACCENT HIGH OUTPUT SYSTEM

INTRODUCTION / TABLE OF CONTENTS

FIST-GSS2. Fist Generic Splicing Shelf MK2. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

EXBLI & EXBSPI Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

19 floor rack with steel door

INLET DUCT FOR CISCO 9513 SWITCH Part Number: DIBBC2314S21W

E Series Enclosures Installation Instructions (UL /UL2416 E Series Equipment Cabinet/Rack)

E.S.P. Embedded Sensing Probes for Motor Brushes

SFUSD Project Number: EXHIBIT D ARGONNE DESIGN DRAWINGS

ipatch Ready Upgrade Kit for SYSTIMAX 360 Fiber Shelves Instructions

Tender for procurement of Passive Components of LAN & Wi-Fi and their installation. Corrigenda. Annexure/Clause For Read

Type N550 Snappy Joe Emergency Shutoff Valves

INSTALLATION INSTRUCTIONS

Installation Instructions: ACCENT SYSTEM

LED IMPORTANT SAFETY INSTRUCTIONS

HS6B Series Subminiature Interlock Switch

ACSI MODEL POWER SUPPLY INSTALLATION INSTRUCTIONS

TV Lift System Model L-75i Installation Instructions

Transcription:

Network Zone System Panduit Corp. 2015 INSTALLATION INSTRUCTIONS Network Zone System Part Numbers: Z22N-****** Z22R-**** Page 1 of 13

TABLE OF CONTENTS Overview of Products Safety Information / Warnings Specs/ Tools Needed Wall Mounting Bracket Installation Wall Mounting Removable Gland Plate Reversible Door Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Recommended Installation Instructions for: Switch Installation Cage Removal Power Entry Uplink Entry Downlink Entry Patch Cord Routing Connect Zone SYS To Uplink Page 10 Page 11 Page 11 Page 11 Page 11 Page 12 Page 13 Page 2 of 13

A B C L J K I H G F E D Network Zone System configurations include an enclosure with required connectivity and cable management, internal factory-connected wiring and includes partner equipment as-specified on the Field Wiring Diagram supplied inside each unit. Additional partner equipment may include one or more of the following DIN-Rail mountable items: A). Industrial automation switch* B). IndustrialNet 8-Port DIN Rail Mount Copper Patch Panel C). Management slack L-rings D). Panduit UPS (interruptible power supply) E). LSM (load sense module) F). Power supplies G). Lockout terminal contact blocks H). Field-wiring terminal for customer-supplied power input wiring I). Ground bar terminal for customer-supplied ground J). Fiber patch box K). Fiber slack spool L). Strain relief bar. *Switch may be included or customer supplied Page 3 of 13

SAFETY INFORMATION DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITIES The practices contained herein are designed as a guide for use by persons having technical skill at their discretion and risk. Panduit does not guarantee any favorable results or assume any liability in connection with these instructions. Local, State, Federal, and Industry Codes and Regulations, as well as manufacturers requirements, must be consulted before proceeding with any project. Panduit Corp. makes no representations of nor assumes any responsibility for the accuracy or completeness set forth herein. Panduit disclaims any liability arising from any information contained herein or for the absence of same. Page 4 of 13

Network Zone System Specifications Standards (May Include) UL 508A IEC 60950-1 IEC 60950-22 EN55022 EN55024 VCCI Enclosure Rating (May include) Environment Installation Dimensions Weight FCC, Part 15, Subpart B ICES-003 UL Type 4/12 and IP66 (IEC 60529), NEMA 4X available All electrical components rated for Class 1, Division 2 environments 40 C ambient outside of enclosure or 60 C maximum within enclosure at up to 95% (non-condensing) humidity Wall mount with optional outside-mount flange Height Width Depth 24 (610 mm) 90 lbs. (40.8 kg) 24 (610 mm) 11.7 (297 mm) **Use Field Wiring Diagram for the Electrical Rating and Maximum Over-current Protection.** **For customer supplied switch use manufacture instructions for installing and wiring.** Tools and supplies needed to complete install of Integrated Zone System: (not included) Fiber-optic trunk cable: FSPD504 or similar LC Fiber-optic connectors: FLCDMCXAQY or similar Fiber-optic termination tools: OptiCam termination kit or similar Category 6 copper cable for downlinks: PUR6504BU-UY or similar Wire cutters for copper cable termination Power wiring: #14 AWG recommended Rigid conduit for power and copper downlink cables Tools to cut enclosure sidewalls: Greenlee punch or similar External Power Disconnect 5/16 bolts for wall mounting of steel enclosure #6 AWG Infrastructure ground cable: RGEJ660PF or similar Screw drivers: #2 Philips, 3/16, and 2.5mm flathead 3/8" bolts for wall mounting of stainless steel enclosure 3/8" socket or box wrench ground bar Switch (Switch ready zone only) Page 5 of 13

Wall Mounting Bracket Installation Note: The enclosure may be mounted to the wall without the mounting brackets Step 1: Turn enclosure on its side with the locks orientated Latch Tool towards the top. Using Latch Tool, turn both locks towards each other to open door. Step 2: Install Wall Mounting Brackets into back of the enclosure aligning threaded studs on brackets to holes located in back of the enclosure. Be sure obround mounting holes on the wall mounting bracket align outward. Step 3: Secure Wall Mounting brackets using sealing washers and (1) per threaded stud. Torque spec: Steel Enclosure: 5/16" washers = 30 in-lbs Stainless Steel Enclosure: 3/8" washers = 40 in-lbs Step 4: Close Door. Using Latch Tool, turn both locks to secure the door. If Mounting Flanges are not used: Step 1 For Steel Enclosure: Use 5/16" Sealing Washer (supplied) and a 5/16" Bolt (not supplied) in the locations where the threaded studs in the mounting flanges would go to mount enclosure directly to wall. For Stainless Steel Enclosure: Use 3/8" Sealing Washer (supplied) and a 3/8" Bolt (not supplied) in the locations where the threaded studs in the mounting flanges would go to mount enclosure directly to wall. Wall Mounting Brackets Step 2 Sealing Washer Hex Nut Detail View Step 3 Washer (provided) Screw (not provided) Page 6 of 13

Wall Mounting Enclosure may be mounted on any wall utilizing Unistrut or by drilling directly into any concrete wall. There are two mounting hole locations on the top flange and two locations at the bottom flange. Step 1: Drill holes 19.25"-22" apart horizontally and 26" apart vertically. Step 2: Mount the enlosure with the locks to the right and secure. If mounting flanges are not used: The holes in the wall will be 22.5" apart horizontally and 34.5" apart vertically. Hole Locations for Wall Mounting Backview for wall mounting Page 7 of 13

Panduit Corp. 2015 2014 INSTALLATION INSTRUCTIONS A Removable Gland Plate The Gland Plate, located on the bottom of the enclosure, is removable for machining to accept bulkhead connectors or compression fittings. Remove (12) screws and (12) flat washers on the bottom of the enclosure to remove plate from the enclosure. Accommodations for incoming conduit have been supplied on the enclosure. A 1/2 conduit plug is installed in the recommended incoming power location. Recommend installation of IP66 rated conduit fittings that comply with the IEC codes that are applicable to the intended application. When reinstalling the gland plate, ensure the screws are tightened until the gland plate flanges make contact with the enclosure surface. Plug Gland plate Page 8 of 13

Reversible Door The enclosure comes with the door opening to the left. The door may be reversed to open to the right. Step 1: Remove pins from the door hinges. Step 2: Remove screws and door hinges Step 3: New Hole locations will have to be drilled or punched out. Reinstall hinges and screws on opposite side. Step 4: Turn door 180 degrees and mount to the opposite side of the enclosure. Insert the same pins to secure the door. STEP 1 STEP 2 STEP 3 Torque 33 in-lbs. Add silicone to bolts (6x) (not supplied) STEP 4 Page 9 of 13

Switch Installation Z22R-**** Only 1 Remove Wiring from Terminal Blocks 2 Remove Terminal Blocks 3 Install Din-rail mounted switch 4 Refer to switch manufacturer for proper wiring installation Switch Installation Instructions 1. Remove wires from terminal blocks 2. Remove terminal blocks 3. Install switch 4. Wire switch - Refer to switch manufacturer s instructions for proper wiring technique. *Note: Install switch before applying power to network zone system. Page 10 of 13

Remove(3) #10-32 screws Cage Removal Recommended Installation Instructions for Power Entry Remove plug in gland plate and replace with conduit fitting. Recommend installation of IP66 rated conduit fittings that comply with the IEC codes that are applicable to the intended application. Install power wiring according to the field wiring diagram Connect infrastructural ground to ground Power Conduit Entry Recommended Installation Instructions for Uplink Entry Recommended Installation Instructions for Downlink Entry Uplink Cable (fiber shown) spooled in the surface mount box Slack loop formed around the L-ring cable managers Uplink Cable Conduit Entry Downlink Cable Conduit Entry See page "13" for details Page 11 of 13

Patch Cord Routing Patch cords supported by the strain relief bar and L-ring managers, routed from the switch to the patch module Fiber patch cord slack on the side mounted spool Page 12 of 13

Connecting to Zone System Uplink Ports Armored Fiber Uplink Fiber Surface Mount Box LC to LC Patch Cords Fiber Spool Assembly The Zone Enclosure can have either a fiber or copper uplink. Copper uplinks are limited to 330ft (100m) distance and relatively noise free environements. It is recommended to have a structured cabling approach, terminating the horizontal cable to an RJ-45 jack or LC adapter. Copper Uplink There are 2 copper RJ-45 uplink ports that can be configured for a star, ring, or linear topology. the copper horizontal cable can be brought straight into the enclosure via conduit. The uplink copper horizontal cables should be terminated to the DIN Patch Box (8 ports). The Patch Panel (48 ports) may be used if patch box is full. The provided Panduit Patch Cords connect the horizontal cable jack to the Stratix. Fiber Uplink The Stratix has 2 SFP uplink ports that can accommodate 2 Fiber SFPs. Either Multi-mode or Single Mode SFPs can be used. Fiber uplinks can be brought into the zone enclosure via conduit, using fiber distribution cable or Panduit armored fiber, DCF, or PCF, as needed. The fiber links are terminated inside the provided fiber Surface Mount Box (CBXF6BL-AY). The Surface Mount Box features internal slack management along with provided Panduit LC adapters (FADJAQLCZBL). Fibers will be terminated to LC connectors (Panduit Opticam FLCDMCXAQY recommended) not included. For instructions on Panduit LC termination, see instruction sheet LC OptiCam Connector : FS014 available on at www.panduit.com. When armored fiber cable is used, the outer casing is connected to the enclosure using Panduit s Armored Cable Grounding Kit (See www.panduit.com for the applicable part no.) The inner distribution cable is exposed and termined in the same manner as other distribution cable. If a metal clad armor casing is used, it will need to be grounded. See T-PMPI-292-PC for armor cable grounding details. From the Surface Mount Box, the provided LC to LC duplex patch cords (FZE10-10M1) are used to connect from the fiber adapter modules to the SFP LC uplink connectors on the switch. Fiber slack is stored in the included fiber spool that is mounted to the accessory plate in the zone enclosure with adhesive. It is important to wind the fiber patch cord slack on the spool to prevent sharp bends or snag that can degrade transmission. For Instructions in Local Languages and Technical Support: http://www.panduit.com/wcs/satellite?pagename=pg_wrapper&friendlyurl=/en/support/contact-us www.panduit.com Page 13 of 13 E-mail: tp-csdebt@panduit.com Fax: (800)777-3300