CAUTION CONTENTS 5.0 WARRANTY

Similar documents
CAUTION 7.0 WARRANTY CONTENTS. 1.0 Overview... 2

1.0 Introduction Mounting Procedure Verifying Calibration Accuracy Specifications Tension Ranges...

6.0 SPECIFICATIONS CONTENTS. Calibration. According to factory procedureeeeeeeeeeeeeee Accuracy*

TABLE OF CONTENTS NOTES. 1.0 Operating principle... 02

TABLE OF CONTENTS 6.0 WARRANTY

TABLE OF CONTENTS. 8.3 Online Sensor Specifications. Series TS (Models TS1, TSP, TSH, TSL,TSF, TSB1, TSB2) According to Electromatic factory procedure

Analog Durometer Model AD-100

Page. 1.0 Overview & Operating Principle Operating Elements Quick Start Instructions Calibration Notes...

Hand-Held Mechanical Tachometer Model HTM

TABLE OF CONTENTS 10.0 LIMITED WARRANTY

CONTENTS 18.0 WARRANTY

NOTES TABLE OF CONTENTS

TABLE OF CONTENTS 10.0 WARRANTY

Coating Thickness Gauges

TABLE OF CONTENTS 11.0 WARRANTY

Tension your belts at the speed of light!

MATERIAL THICKNESS GAUGES

Tension Meter. PT Series. Instruction Manual PT-100-L. Valid as of: Please keep the manual for future reference!

1.0 Introduction Precautions

Model E600 Tarping System

Tension Meter. Edition FT 03.E. FT Series. Instruction Manual. Valid as of: Please keep the manual for future reference!

Model AS-FM64 Wall Mount. Full Motion Television Wall Mount

HQZ & RBM MODEL LIFT & TRANSFERS

Mechanical Spiral Sensor

Operating Instructions

SIDE-WIND, A-FRAME TRAILER JACK. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

SAVE THESE INSTRUCTIONS

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-122 REV A 12/09

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09

Adjustable Shop Stool with Backrest

Intelligent Electronic Safe

Model AS-RC3260 TV Cart. Rolling Cart for Audio Mount System & Flat Panel TVs

Model T2642 Wall Mount. Television Wall Mount with Tilt Option

INTRODUCTION INSTALLATION

Electric Actuator Installation, Operation & Maintenance Manual

INSTALLATION INSTRUCTIONS

Owner s Manual & Safety Instructions

Model FM2642 Wall Mount. Full Motion Television Wall Mount

NEW GEN OWNER S MANUAL

AUTO-BLiP. User Manual Lotus INTELLIGENT DOWNSHIFTS. Version 1.0

MBF-P 2040 PLASTIC MODULAR BELT CONVEYOR

1250 LB. CAPACITY MECHANICAL WHEEL DOLLY

SAVE THESE INSTRUCTIONS WARNING

KFM-P 2040 INCLINE BELT CONVEYOR

AUTO-BLiP. User Manual Ford Mustang INTELLIGENT DOWNSHIFTS. Version 1.2

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

2000-LB. ENGINE STAND

Penguin Gentoo 600B Cordless Sprayer User s Manual

LT-EL138 LED Flashlight

SAVE THESE INSTRUCTIONS DANGER

1/2-TON MANUAL CHAIN HOIST

PCC O P E R A T I O N S. Pump Cycle Counter M A N U A L. Environmental Systems

GRINNELL Model B302 and Model BN302 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description

ST-70 CONTROL OPERATING MANUAL REVISION DATE: PART#:

1000-LB. ENGINE STAND

Dual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev

6701 KNIFE GATE VALVES

PRG 350 Series Stainless Steel Regulators

Microscope light manual

AUTO-BLiP. User Manual Chevrolet Corvette. Version 1.2

RENA AF371Feeder Operating Manual. Feeder. Operating Manual. Manual Part #: M AF371 Operations Rev

IMPORTANT SAFETY INFORMATION

Installation Guide. Marking and Inspection Gauge. Marking Gauge. Inspection Gauge E 1. Marking and inspection gauges are combined into one gauge.

Installation Instructions

Control Gate Valve with stepper motor actuator

3000-Lb. Vehicle Positioning Jacks. Owner s Manual

Low-Profile Drum Caddy

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

2.4mm Coaxial Calibration Kit

Rectangular Door L-VAT with pneumatic actuator double acting

Unilift KP 150, KP 250, KP 350

TONS. Before each shift: Before operating: Before initial operation of hoist:

PLEASE ENSURE THE JUMP STARTER IS FULLY CHARGED PRIOR TO FIRST USE.

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

3.5mm Coaxial Calibration Kit

CRD610 Automatic Fitting Inserter

Air Curtain. Installation, Operating and Maintenance Instructions

Cam Timing Tool 850 all, S/V/C only ipd #

PVI 60KW, PVI 82KW, PVI 95KW

GUF-P MINI BELT CONVEYOR

Drum Deheader. Owner s Manual

UniTorq UTQ Quarter-Turn Actuator Installation and Operation Manual

ERD Electrically Released Brakes

Model:M5B/M5W/M5N. Installation Guide. Specifications Desktop Weight Capacity Keyboard Tray Weight Capacity Height Adjustable Range

PUSH BUTTON KEY CABINET

Angle Grinder Holder

Power Supply. Model PS-200

AUTO-BLiP. User Manual Chevrolet Corvette. Version 1.7

A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1

6-TON DOUBLE LOCKING JACK STANDS OWNER S MANUAL

ECONOMAIR SERIES CYLINDERS

"WHERE TUBING AND FITTINGS COME TOGETHER"

SPECIFICATIONS GENERAL SAFETY RULES PERSONAL SAFETY. Save This Manual TOOL USE AND CARE WORK AREA

Read this entire manual before operation begins.

3M-MaticTM. Tape Edge Fold Kit. Instructions and Parts List. For Use On: AccuGlide TM STD Upper and lower Taping Heads. Purpose of Attachment

ATD Gallon Pressurized Oil Drain Owner s Manual

AUTO-BLiP. User Manual Porsche INTELLIGENT DOWNSHIFTS. Version 1.2

RoughDeck TM FXB Flexure Base Floor Scale. Installation/Operation Manual

Installation Instructions Receiver Rack (Part # 7700) Universal Application

Transcription:

5.0 WARRANTY ELECTROMATIC Equipment Co., Inc. (ELECTROMATIC) warrants to the original purchaser that this product is of merchantable quality and confirms in kind and quality with the descriptions and specifications thereof. Product failure or malfunction arising out of any defect in workmanship or material in the product existing at the time of delivery thereof which manifests itself within one year from the sale of such product, shall be remedied by repair or replacement of such product, at ELECTROMATIC s option, except where unauthorized repair, disassembly, tampering, abuse or misapplication has taken place, as determined by ELECTROMATIC. All returns for warranty or non-warranty repairs and/or replacement must be authorized by ELECTROMATIC, in advance, with all repacking and shipping expenses to the address below to be borne by the purchaser. THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO, THE WARRANTY OF MERCHANTABILITY AND FITNESS FOR ANY PARTICULAR PURPOSE OR APPLICATION. ELECTROMATIC SHALL NOT BE RESPONSIBLE NOR LIABLE FOR ANY CONSEQUEN- TIAL DAMAGE, OF ANY KIND OR NATURE, RESULTING FROM THE USE OF SUPPLIED EQUIPMENT, WHETHER SUCH DAMAGE OCCURS OR IS DISCOVERED BEFORE, UPON OR AFTER REPLACEMENT OR REPAIR, AND WHETHER OR NOT SUCH DAMAGE IS CAUSED BY MANUFACTURER S OR SUPPLIER S NEGLIGENCE WITHIN ONE YEAR FROM INVOICE DATE. Some State jurisdictions or States do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you. The duration of any implied warranty, including, without limitation, fitness for any particular purpose and merchantability with respect to this product, is limited to the duration of the foregoing warranty. Some states do not allow limitations on how long an implied warranty lasts but, not withstanding, this warranty, in the absence of such limitations, shall extend for one year from the date of invoice. CONTENTS 1.0 Operation................................................ 2 1.1 Fastening the MK Tensionmeter 1.2 Inserting the material to be measured 1.3 Air Damping (Option) 1.4 MIN/MAX Contacts 2.0 Verifying the MK Calibration................................ 5 2.1 Checking Procedure 3.0 Service and Maintenance................................... 6 3.1 Rollers 3.2 Cleaning 3.3 Verification Intervals 4.0 Specifications............................................ 7 4.1 Roller Guides 4.2 Available Models 5.0 Warranty................................................. 8 ELECTROMATIC Equipment Co., Inc. 600 Oakland Ave. Cedarhurst, NY 11516 USA Tel: 1-800-645-4330/ Tel: 516-295-4300/ Fax: 516-295-4399 Every precaution has been taken in the preparation of this manual. Electromatic Equipment Co., Inc., assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of information contained herein. Any brand or product names mentioned herein are used for identification purposes only, and are trademarks or registered trademarks of their respective holders. CAUTION Tensions that exceed the tension range of the MK instrument by more than 100% may cause permanent damage to the movement and must be avoided under any circumstances. -1- -8-

1.0 OPERATION 1.1 Fastening the MK Tensionmeter Two mounting holes are provided for fastening the tensionmeter on site. For the mounting hole dimension, see the figure below. Mounting Hole diameter 3.1 mm 4.0 SPECIFICATIONS Calibration: According to SCHMIDT factory procedure Accuracy: ± 1% full scale (FS) or ± 1 graduation on scale Scale diameter: 43 mm Temperature range: 10 45 C Air humidity: 85% RH, max. Housing material: Plastic (Makrolon) Housing dimensions: 96mm x 44mm x 2 mm (L x W x H) Weight, net (gross): approx. 80 g (200 g) 30 mm 4.1 Roller Guides 46 mm Mounting Hole diameter 3.1 mm 1.2 Inserting the material to be measured Thread the material to be measured carefully through the measuring and guides as shown in the figure Roller at right. it is important to ensure that guides the material runs smoothly through the guides and the measuring. CAUTION To avoid damage, do not move the center using force. You can now read the measured tension on the scale. Scale 1.3 Air Damping (Optional Accessory code A) Measured material Measuring The measuring system of the MK can be factory-equipped with a dashpot. This dashpot makes it possible to absorb approximately 50% of the pointer oscillations. We recommend application of the dashpot in the case of high tension fluctuations (spooling or winding). The setting of the dashpot has to be tuned to the local conditions by experimenting. V-grooved Line Speed M/min max. Roller Material Standard 1000 Hardcoated aluminum Code T 1000 Plastic (POM) black Code W 1000 Nickel-plated steel 4.2 Available Models Type Measuring range cn **Factory Calibration Material MK-12 12 3 Filament: 25 tex MK-20 05 20 Filament: 25 tex MK-30 05 30 Filament: 25 tex MK-50 10 50 PA: 0.12mm Ø MK-100 10 100 PA: 0.12mm Ø MK-250 20 250 PA: 0.12mm Ø MK-300 20 300 PA: 0.20mm Ø MK-400 50 400 PA: 0.20mm Ø ** Suitable for 95% of applications. PA = Polyamide Monofilament If the material to be measured differs significantly from the SCHMIDT calibration material in diameter, rigidity, shape, etc., we recommend calibration using customer material. For this purpose, a material sample of about 5 m should be supplied. International unit for tension force:1 cn = 1.02 g = 0.01 N -2- -7-

3.0 SERVICE AND MAINTENANCE The tension meter is easy to maintain. Depending on operating time and load, the tension meter should be checked according to the locally valid regulations and conditions. Other testing methods as can cause different measuring readings. 3.1 Rollers You should regularly inspect the s to assure that they are running easily and smoothly. You can replace the s yourself, as necessary. When ordering spare s, please indicate the tension meter model and the serial number (on the rear side of the tension meter). Ordering of spare s Model: MK-12 (on the right side of the tension meter) Serial number: 300-888888 (on the right side of the tension meter) Standard s: Order number R12013 To set the Dashpot 1. Turn the setscrew clockwise as far as it will go (screw is protected against overturning). The dashpot is now at its maximum setting. 2. Screw the setscrew out again counter-clockwise until the desired damping factor for the scale pointer is achieved. Note: A change in the damping factor is only possible within the first three counterclockwise revolutions of the setscrew. 3. Turn the setscrew clockwise to increase damping. 4. Turn the setscrew counterclockwise to reduce damping. Setscrew Dashpot 3.2 Cleaning For cleaning the unit, do not use any AGGRESSIVE SOLVENTS such as trichloroethylene or similar chemicals. NO WARRANTY OR LIABILITY shall be accepted for damage resulting from improper cleaning. Soldering tag for cable connection MIn Setscrew Locknuts MAX Setscrew 3.3 Verification Intervals The question of finding the right frequency of calibration accuracy verification depends on several different factors: Operating time and load of the SCHMIDT tension meter Tolerance band defined by the customer Changes of the tolerance band compared to previous verifications of calibration Therefore, the interval between verifications must be determined by the user`s Quality Assurance Department based on the user`s experience. Assuming normal operating time and load as well as careful handling of the tension meter, we recommend a verification interval of 1 year. max. 24 V / 2 W 1.4 Min/Max Contacts (Optional Accessory Code D) Your MK tensionmeter can be factory-equipped with Min/Max tensiondetecting contacts which allow you to monitor the tolerance limits for the measured tension. We recommend application of the tension-detecting screw contacts in case of automated production sequences. These factory-installed -6- -3-

contacts are free from potential. Instead of the the lamps shown in the illustration shown on page 3, it is, of course, possible to connect other equipment, such as bell, horn, relay, etc. The contact load specified in the figure on page 3 of max. 24 V / 2 W must not be exceeded. The setting of the desired tolerance range has to be tuned to the local conditions by experimenting. To set the MAXIMUM tolerance limit: 1. Loosen the locknut on the MAX setscrew. 2. Turn the setscrew counterclockwise to decease the MAXIMUM tolerance, or 3. Turn the setscrew clockwise to increase the MAXIMUM tolerance. 4. Tighten the locknut on the MAX setscrew again. To set the MINIMUM tolerance limit: 1. Loosen the locknut on the MIN setscrew. 2. Turn the setscrew clockwise to decrease the MINIMUM tolerance, or 3. Turn the setscrew counterclockwise to increase the MINIMUM tolerance. 4. Tighten the locknut on the MIN setscrew again. 2.0 VERIFYING THE MK CALIBRATION All tension meters are calibrated with standard materials such as polyamide monofilament (PA) according the factory procedure. Filament sizes are noted in Section 4.2. Any difference in process material size and rigidity from the standard material may cause a deviation of the accuracy. In 95 % of all industrial applications the factory calibration has been proven to provide the best results and is used for comparative purposes. If the process material differs significant in size, rigidity and shape we recommend special calibration using customer`s sample. For this purpose a material sample of 5 m should be supplied. 2.1 Checking procedure 1. Suspend a known weight that corresponds to the tension to be measured (pay attention to the correct unit of measure) from the Process material, vertically, as shown in the figure. Always use a fresh portion of the material to be measured. 2. Before the final check, move the Process material slowly up and down to compensate any friction caused by the instrument and thus ensure the repeatability. 3. The tension value should be equal to the value of the suspended weight. Guide If this procedure shows a deviation beyond the allowable tolerance and a reliable operation is no longer allowed, the instrument has to be recalibrated or repaired. For recalibration, return the tension meter to the factory. Process material Measuring Scale Weight -4- -5-

Model MK TENSIONMETER CHECK LINE BY ELECTROMATIC CHECK LINE INSTRUMENTS ELECTROMATIC E Q U I P M E N T C O., I N C. 600 Oakland Ave., Cedarhurst, NY 11516 U.S.A. TEL: 516-295-4300 FAX: 516-295-4399 Operating Instructions