1329I Integrated Drive/Motor CE Filter Option Kit

Similar documents
M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

1204 Terminator. Instructions 1204 T F B2. (Catalog Number 1204-TFA1, 1204-TFB2) Where this Option is Used. What this Option Contains

1370 DC Loop Contactors and Lug Kits

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

High Frequency SineWave Guardian TM

M T E C o r p o r a t i o n. MTE Series RL. Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL MTE Corporation

Allen-Bradley Motors. NRU Diode Bridge Assembly Replacement ( A DC) REPLACEMENT KIT INSTRUCTIONS. Contents. What This Kit Contains

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide

BR Second Position Voltages. AA Fourth Position

Power Fuse Assembly Replacement (for 3000A 1395 DC Drives)

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL MTE Corporation

Series P215PR Direct Mount Pressure Actuated Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

MATRIX FILTER USER MANUAL. SERIES D 400 Volts, 50HZ PART NO. INSTR 025 REL REV MTE Corporation

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL REV MTE Corporation

MATRIX FILTER USER MANUAL. SERIES D 480 Volts, 60HZ PART NO. INSTR 024 REL REV MTE Corporation

SECTION WELDING FUME EXHAUST SYSTEM

Pneumatic Isolation Module

Application Description

Dimensions WxHxD [mm] Weight [kg]

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

DC/DC converters - MINI-PS DC/ 5-15DC/

SOLSTART Instruction Manual

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

Data Bulletin. ALTIVAR FLEX58 Chassis Drive Controllers Class 8806 INTRODUCTION DESIGN CONCEPT. Bulletin No. 8806DB0102 August 2001 Raleigh, NC, USA

Series A DC Link Chokes

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

MF /MS Series

Capacitors. Individual & fixed bank. Individual & fixed capacitor banks. Low Voltage Network Quality

Chapter. Installation and. In this Chapter...

CP-8551 & CP Application. Features. Applicable Literature. Electronic to Pneumatic Transducers General Instructions

A22NK. Key-type Selector Switches

PowerFlex 700H and 700S AC Drives Frame 9 Main Fan Capacitor Replacement Kit

Installation Instructions

M T E C o r p o r a t i o n. MTE Series RL. Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL MTE Corporation

ALTIVAR FLEX58 Chassis Drive Controller Product Selection

AT30 SERIES BATTERY CHARGER

BK BK J93 MA BK MA BK MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

Pulse Encoder Interface Kit For Use With FlexPak 3000 and WebPak 3000 DC Drives M/N 907FK0101

Industrial Control Transformers

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

Single & Three-Phase Soft Starters

362 Clamp Meter. Users Manual

Double Pole Circuit Breaker Kit for Non-Regenerative MinPak Plus DC Drives

Compact Circuit Protector

O & M Manual for the EATON Generator Ready Loadcenter

Allen-Bradley HP Inverting Fault Circuit Breaker Kit

BK BK A BK MA BK MA BK J93 MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

CAUTION CM-SE CM-S21 CM-S41

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

MF4E MF4E

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

AC Line / Load Reactors

ALTIVAR 58 TRX Adjustable Speed Drive Controllers Installation Guide, Type H Controllers

BRAQCPC IT T. Goulds Pumps AQUAVAR CPC. Variable Speed Centrifugal Pump Controller. Engineered for life

5 x 20mm Fuses S500 Series, Fast-Acting, Glass Tube

CP-9301 CP Application. Features. Applicable Literature. Electronic Actuator Drives General Instructions

ABB central inverters ULTRA-750/1100/ kW to 1560kW

Packing Data Installation Instructions

An Investment in Plant Floor Safety. 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches

Series P215ST Single Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

ALL PURPOSE CNC/HEAVY DUTY

Switching DC Power Supply

Power conversion systems for energy storage. Engineering that stores

External Bus Resistor Kit for LiquiFlo AC Drives Drive M/N s 50L4060, 50LW4060, 50LR4060, 64L4060, 64LW4060, 64LR4060, LF150500W4, LF150643W4

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 480 Volts, 60Hz. Page 1 of 14. April 15, 2010: updated capacitor UL File number)

CONTROL FEATURES AVAILABLE OPTIONS

Inverting Fault Circuit Breaker Kit for FlexPak 3000 and WebPak 3000 Digital DC Drives VAC and VAC

Boston Gear Ratiotrol DC Motor Speed Control

MA-5200 Series MA-5300 Series

UZK12.261, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 26AH 1/10.

Allen-Bradley Parts. CENTERLINE 2500 Motor Control Centers Installing, Joining and Splicing Columns. Installation Instructions. Catalog Number 2500

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions.

poollux Power plx-pw60 & plx-pw100

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

These documents contain additional information concerning related products from Rockwell Automation.

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

User Manual. Solar Charge Controller 3KW

Thyristor power controller TE10A. Burst-firing Single-cycle Advanced Single-cycle

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Low voltage AC drives

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame

PowerFlex 700 User Manual Update

SECTION VARIABLE FREQUENCY DRIVE UNITS

Braking Unit, Braking Resistor Unit

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

Transcription:

Instruction Sheet 1329I Integrated Drive/Motor CE Filter Option Kit CE filter options are designed to be used with the 1329I Integrated Drive/Motor. The main function of the CE filter is to reduce the radio frequency conducted emissions into the main supply lines and ground wiring. This publication provides the steps needed to install the filter. Important: Declarations of Conformity to the European Union Directives are available for Allen-Bradley AC drive products. Please contact your Allen-Bradley Sales Representative. ATTENTION: The CE filter connects between the incoming AC supply line and the drive input terminals. The filter must be installed by qualified personnel familiar with the drive and associated machinery. Failure to comply may result in personal injury and/or equipment damage. ATTENTION: An incorrectly applied or installed CE filter can result in component damage or a reduction in product life. Wiring or application errors, such as incorrect wiring layout, incorrect or inadequate AC supply or excessive ambient temperatures may result in malfunction of the system. Refer to the page listed below for installation instructions. Internal Mount Option See page 2. NEMA 12 Enclosed Option See page 5.

2 1329I Integrated Drive/Motor CE Filter Option Kit Internal Mount Installation Use the cross-reference table below to verify that the correct filter has been selected for your CE compatible drive. Filter Selection Filter Catalog Number Series Ratings 1329I-NLF1 A 115/230 VAC Single Phase 14 Amps 1329I-NLF3 A 230/460 VAC Three Phase 9 Amps Use with Bulletin 1329I Series B Drive/Motor 1329I-BJ 1329I-BK 1329I-BL 1329I-BM Components Supplied Item Quantity Supplied Quantity Required to Install Screws M4 8 TT Lock Washers M4 Internal Tooth 5 4 5 4

1329I Integrated Drive/Motor CE Filter Option Kit 3 Filter Installation ATTENTION: To prevent electrical shock, disconnect the power source before installing or servicing. ATTENTION: After disconnecting input power wait five minutes and check with voltmeter to assure that DC bus capacitors are discharged (DC+, DC-). The voltmeter should read zero volts. Failure to observe these precautions could result in severe bodily injury or loss of life. 1. Remove the cover of the 1329I unit by loosening the four cover screws. The display ribbon cable is designed to disconnect from the main unit when the cover is removed. 2. Mount the CE filter as shown in the figure below using the screws provided. 1.46 Nm (13 in-lb) 2.6 Nm (23 in-lb) 3. The CE filter must be connected between the incoming AC supply line and the drive input terminals. Important: The filter may cause ground leakage currents. Therefore, a solid ground connection must be provided as shown on the following page.

4 1329I Integrated Drive/Motor CE Filter Option Kit ATTENTION: To guard against possible equipment damage, RFI filters can only be used with AC supplies that are nominally balanced with respect to ground. In some installations, threephase supplies are occasionally connected in a 3-wire configuration with one phase grounded (Grounded Delta). The filter must not be used in Grounded Delta supplies. Filter Wiring CE Filter 1329I Integrated Drive Motor Conduit/4-Wire Cable L1 IN W1 OUT R/L1 L2 IN W2 OUT S/L2 L3 IN W3 OUT T/L3 Nearest Building Structure Steel 4. Connect wires as shown in the diagram below. (Three Phase unit shown.) 1.3 Nm (12 in-lb) L1 L2 L3 DC+ DC- DBR T/L3 S/L2 R/L1 1.3 Nm (12 in-lb)

1329I Integrated Drive/Motor CE Filter Option Kit 5 5. Reconnect display ribbon cable and reinstall cover. ATTENTION: The cover screws must be securely tightened in order to properly ground the cover. Verify that all four cover screws are tight before applying power to the unit. Failure to observe this precaution could result in severe bodily injury or loss of life. NEMA 12 Enclosed Installation Use the cross-reference table below to verify that the correct filter has been selected for your CE compatible drive. Filter Selection Filter Catalog Number Series Ratings 1329I-JLF1 A 115/230 VAC Single Phase 14 Amps 1329I-JLF3 A 230/460 VAC Three Phase 9 Amps Use with Bulletin 1329I Series B Drive/Motor 1329I-BJ 1329I-BK 1329I-BL 1329I-BM Filter Enclosure Dimensions mm (in) 29.0 (1.13) 152.0 (6.0) 10.0 (0.38) 113.0 (4.46) 292.0 (11.5) 273.0 (10.75) 225.0 (8.87) 3.0 (0.10)

6 1329I Integrated Drive/Motor CE Filter Option Kit Filter Installation ATTENTION: To prevent electrical shock, disconnect the power source before installing or servicing. ATTENTION: The National Codes and standards (NEC, VDE, BSI, etc.) and local codes outline provisions for safely installing electrical equipment. Installation must comply with specifications regarding wire types, conductor sizes, branch circuit protection, and disconnect devices. Failure to do so may result in personal injury and/or equipment damage. 1. Mount the NEMA 12 Enclosed CE filter. The cable length from the filter to the drive/motor must be less than 3 meters (10 feet). 2. The RFI filter must be connected between the incoming AC supply line and the drive input terminals. Important: The filter may cause ground leakage currents. Therefore, a solid ground connection must be provided as shown on the following page. ATTENTION: To guard against possible equipment damage, RFI filters can only be used with AC supplies that are nominally balanced with respect to ground. In some installations, threephase supplies are occasionally connected in a 3-wire configuration with one phase grounded (Grounded Delta). The filter must not be used in Grounded Delta supplies.

1329I Integrated Drive/Motor CE Filter Option Kit 7 Filter Wiring CE Filter 1329I Integrated Drive/Motor Conduit/4-Wire Cable L1 IN L1' OUT R/L1 L2 IN L2' OUT S/L2 L3 IN L3' OUT T/L3 Nearest Building Structure Steel 3. Connect the wires to the CE filter as shown in the diagram below. (Three Phase unit shown.) 0.3-0.8 Nm (3-7 in-lb) 1.3 Nm (12 in-lb) L1 L2 L3 2.8 Nm (25 in-lb) IN OUT Incoming AC Power To Integrated Drive/Motor AC Input Terminals

Bulletin 1329I CE Filter Option Specifications 1329I-NLF1 1329I-NLF3 1329I-JLF1 1329I-JLF3 Input Voltage 115/230 VAC 230/460 VAC 115/230 VAC 230/460 VAC Input Phases Single Phase Three Phase Single Phase Three Phase Frequency 50/60 Hz Rated Current 14 Amps 9 Amps 14 Amps 9 Amps Power Dissipation Leakage Current (Worst Case) 5 Watts 0.5 ma Weight 0.33 Kg (0.73 lb) 0.45 Kg (0.99 lb) 4.72 Kg (10.41 lb) 4.89 Kg (10.78 lb) Enclosure Internal NEMA 12/IP 65 Operating Temperature Storage Temperature Relative Humidity Vibration Shock Altitude International Standards and Approvals 0 to 40 C (32 to 104 F) -40 to 85 C (-40 to 185 F) 5% to 95%, non-condensing 1 G operational, 2.5 G non-operational 15 G operational, 30 G non-operational 1000 meters (3300 feet) without derating. For every 91.4 meters (300 feet) above 1000 meters, derate current by 1%. Above 3000 meters (10,000 feet), consult your Allen-Bradley Sales Office. LISTED 966X UL IND CONT EQ UL508C LISTED 966X C UL CSA 22.2 IND CONT EQ EMC Directive 89/336 LV: EN 50178, EN 60204 EMC: EN 61800-3, EN 50081-1, EN 50082-2 Publication 1329I-5.4 January, 2000 P/N 194395 (01) Copyright 2000 Rockwell International Corporation. Printed in USA