SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 130 kw 163 kva 60 Hz

Similar documents
Standby Rated Generators. Standby SG kva / 28 kw. Prime PG kva / 22 kw

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 80 kw 100 kva 60 Hz

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 70 kw 88 kva 60 Hz

Power Ratings. Standby SG kva / 160 kw. Prime and standby ratings based on 3-Phase voltages. Model number based on kw rating.

Power Ratings. Standby SG kva / 240 kw. Prime PG kva / 192 kw

MG L. MG Series Paralleling Unit. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. MG kw

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 150 kw 188 kva 60 Hz

Standby Rated Generators. Standby SG kva / 184 kw. Prime PG kva / 147 kw

Power Ratings. Standby SG kva / 320 kw. Prime PG kva / 288 kw

SG L 50 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

SG L 35 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency POWERING AHEAD CODES AND STANDARDS

G130LG2 6.8L. Industrial Spark-Ignited Generator Set. Codes and Standards. G130LG2 130 kw. Standby Power Rating 130 kw 163 kva 60 Hz

SG L 250 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

MG L. MG Series Paralleling Unit. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. MG kw

INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency CODES AND STANDARDS POWERING AHEAD

SG L 300 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

G150LG4 12.9L. Industrial Spark-Ignited Generator Set. Codes and Standards. G150LG4 150 kw. Standby Power Rating 150 kw 188 kva 60 Hz

INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency CODES AND STANDARDS POWERING AHEAD

MG L 150 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 60 kw 75 kva 60 Hz

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 20 kw 25 kva 60 Hz

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 130 kw 163 kva 60 Hz

SG L 350 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

QT025A 2.4L 25 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

SD L 40 kw INDUSTRIAL DIESEL GENER ATOR SET EPA Certified Stationary Emergency

MD L 400 kw INDUSTRIAL DIESEL GENER ATOR SET EPA Certified Stationary Emergency

SD L 130 kw INDUSTRIAL DIESEL GENER ATOR SE T EPA Certified Stationary Emergency

SD L. Industrial Diesel Generator Set. Powering Ahead. Codes and Standards. SD kw

SD L 1000 kw INDUSTRIAL DIESEL GENER ATOR SET EPA Certified Stationary Emergency

MD L. Industrial Diesel Generator Set. Powering Ahead. Codes and Standards. MD kw. Standby Power Rating 1000 kw 1250 kva 60 Hz

INDUSTRIAL DIESEL GENER ATOR SE T CODES AND STANDARDS POWERING AHEAD. STANDBY POWER RATING 400 kw, 500 kva, 60 Hz

SB500/MB500. Industrial Bi-Fuel Diesel Generator Set. 500 kw Bi-Fuel. features. primary codes and standards. Standby Power Rating 500 kw 625 kva 60 Hz

MD L. Industrial Diesel Generator Set. Powering Ahead. Codes and Standards. MD kw

MG L. MG Series Paralleling Unit. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. MG kw

MD L 1000 kw INDUSTRIAL DIESEL GENER ATOR SET EPA Certified Stationary Emergency

SB600/MB600. Industrial Bi-Fuel Diesel Generator Set. features. primary codes and standards. 600 kw Bi-Fuel. Standby Power Rating 600 kw 750 kva 60 Hz

G150LG6. Industrial Spark-Ignited Generator Set. Codes and Standards. G150LG6 150 kw. Standby Power Rating 150 kw 188 kva 60 Hz

70 kw GENERAC STANDBY GENERATORS. Liquid-Cooled Engine Generator Sets FEATURES INCLUDES: Standby Power Rating Model QT070 (Bisque) - 70 kw 60Hz

SG L 130kW POWERING AHEAD. CODES AND STANDARDS Not all codes and standards apply to all configurations. Contact factory for details.

MG L 130 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET. Codes and Standards. Powering Ahead. Standby Power Rating 130 kw, 163 kva, 60 Hz

GENERAC GUARDIAN SERIES STANDBY GENERATORS

GENERAC GUARDIAN SERIES STANDBY GENERATORS

SG070. Industrial Gaseous Generator Set. SG070 70kW. primary codes and standards. Standby Power Rating 88kVA 70kW 60 Hz

GENERAC GUARDIAN SERIES STANDBY GENERATORS

GENERAC GUARDIAN SERIES STANDBY GENERATORS

22 kva GENERAC STANDBY GENERATORS ISO. Liquid-Cooled Engine Generator Sets FEATURES INCLUDES:

PROTOTYPE & TORSIONALLY TESTED UL2200 TESTED RHINOCOAT PAINT SYSTEM WIDE RANGE OF ENCLOSURES EPA COMPLIANT INDUSTRIAL TESTED, GENERAC DESIGNED

GENERAC QUIETSOURCE SERIES STANDBY GENERATORS

GENERAC GUARDIAN SERIES STANDBY GENERATORS

G130LG. Industrial Gaseous Generator Set. G130LG 130kW. primary codes and standards. Standby Power Rating 163kVA 130kW 60 Hz

GENERAC QUIETSOURCE SERIES STANDBY GENERATORS

GENERAC GUARDIAN SERIES STANDBY GENERATORS

SG150. Industrial Gaseous Generator Set. SG kW. primary codes and standards. Standby Power Rating 188kVA 150kW 60 Hz

MG L 150kW POWERING AHEAD. CODES AND STANDARDS Not all codes and standards apply to all configurations. Contact factory for details.

STANDBY GENERATOR 25 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

DATA CENTER SOLUTIONS

STANDBY GENERATOR 80 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

1P 120/240V, 3600 RPM,

STANDBY GENERATOR 130 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

STANDBY GENERATOR 100 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

Standby Generators ISO FEATURES. Standby Generators Liquid-Cooled Gaseous Engine. Standby Generators INCLUDES:

SG L 300kW. CODES AND STANDARDS Not all codes and standards apply to all configurations. Contact factory for details.

G300LG. Industrial Gaseous Generator Set. G300LG 300kW. primary codes and standards. Standby Power Rating 375kVA 300kW 60 Hz

SG L 200kW. CODES AND STANDARDS Not all codes and standards apply to all configurations. Contact factory for details.

MDG75DF4 4.5L 75 kva MOBILE DIESEL GENERATOR SET. Power When and Where You Need It

Spark-ignited generator set

DG175 GC to DG450 GC GAS GENERATOR SETS

Protector Series ISO FEATURES. Standby Generators Liquid-Cooled Gas Engine INCLUDES:

MDG75DF4 4.5 L 75 kva MOBILE DIESEL GENERATOR SET. Power When and Where You Need It

G50U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

Guardian Series. GUARDIAN SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES. Guardian Series INCLUDES:

60 Hz FEATURES. Exclusively from your Caterpillar dealer

Diesel generator set QSK23 series engine

Diesel generator set. QSB5 series engine Hz EPA Tier 3 emissions. Specification sheet. Description. Features

Quietsource Series ISO. QUIETSOURCE SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES. Quietsource Series INCLUDES:

Spark-ignited generator set

Centurion Series. CENTURION SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES. Centurion Series INCLUDES:

G100U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

DIESEL GENERATOR SET. 60 Hz FEATURES

Diesel generator set. 20 kw EPA emissions stationary Standby. Specification sheet. Description. Features

Diesel generator set QSX15 series engine

DIESEL GENERATOR SETS

60 Hz FEATURES. Exclusively from your Caterpillar dealer

SPECIFICATIONS. Stationary Emergency Generator Specifications STATIONARY EMERGENCY GENERATOR COOLING SYSTEM FUEL SYSTEM ENGINE ELECTRICAL SYSTEM

Diesel generator set. 50 kw - 60 kw EPA emissions stationary Standby. Specification sheet. Description. Features

13,000 Watt Diesel Generator AGi13P E

Siemens Liquid Cooled Standby Generators

AGi20P 2.2 L 20 kw Perkins Powered Diesel Generator AURORA GENERATORS INCORPORATED AURORA STANDARD FEATURES STANDBY POWER RATING 20 KW, 20 KVA, 60 HZ.

RENTAL DIESEL GENERATOR SET

Diesel generator set QSB7 series engine

MG L 750kW. CODES AND STANDARDS Not all codes and standards apply to all configurations. Contact factory for details.

MG300. Industrial Gaseous Generator Set. MG kW. primary codes and standards. Standby Power Rating 375kVA 300kW 60 Hz PARALLELING UNIT

PROTOTYPE & TORSIONALLY TESTED PROVIDES A PROVEN UNIT UL2200 TESTED ENSURES A QUALITY PRODUCT RHINOCOAT PAINT SYSTEM IMPROVES RESISTANCE TO ELEMENTS

MDG100DF4CAN 4.5 L 100 kva MOBILE DIESEL GENERATOR SET. Codes and Standards Generac Mobile products are designed to the following standards:

10,000 Watt Diesel Generator AGi9P E

Diesel generator set QSK23 series engine

G80U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

Protector Series ISO. PROTECTOR SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES INCLUDES:

Diesel generator set QSX15 series engine

Transcription:

SG130 6.8L Industrial Spark-Ignited Generator Set EPA Certified Stationary Emergency SG130 130 kw Power Rating 130 kw 163 kva 60 Hz Codes and Standards Generac products are designed to the following standards: UL2200, UL508, UL142, UL498, ETL NFPA70, 99, 110, 37 NEC700, 701, 702, 708 ISO9001, 8528, 3046, 7637, Pluses #2b, 4 Powering Ahead Image used for illustration purposes only For over 50 years, Generac has led the industry with innovative design and superior manufacturing. Generac ensures superior quality by designing and manufacturing most of its generator components, including alternators, enclosures and base tanks, control systems and communications software. Generac s gensets utilize a wide variety of options, configurations and arrangements, allowing us to meet the standby power needs of practically every application. NEMA ICS10, MG1, 250, ICS6, AB1 ANSI C62.41 Generac searched globally to ensure the most reliable engines power our generators. We choose only engines that have already been proven in heavy-duty industrial application under adverse conditions. IBC 2009, CBC 2010, IBC 2012, ASCE 7-05, ASCE7-10, ICC-ES AC-156 (2012) Generac is committed to ensuring our customers service support continues after their generator purchase.

SG130 130 kw SG130 Standard Features ENGINE SYSTEM ALTERNATOR SYSTEM ENCLOSURE General Oil Drain Extension Air Cleaner Fan Guard Stainless Steel flexible exhaust connection Critical Exhaust Silencer Factory Filled Oil Radiator duct adapter (open set only) Fuel System Primary and Secondary Fuel Shutoff Flexible Fuel Line - NPT Connection Cooling System Closed Coolant Recovery System UV/Ozone resistant hoses Factory-installed Radiator Radiator drain extension 50/50 Ethylene glycol antifreeze UL2200 GENprotect Class H insulation material 2/3 Pitch Skewed Stator Brushless Excitation Sealed Bearings Amortisseur winding Full load capacity alternator GENERATOR SET Internal Genset Vibration Isolation Separation of circuits - high/low voltage Separation of circuits - multiple breakers Wrapped Exhaust Piping (enclosed only) Standard Factory Testing 2 Year Warranty Silencer mounted in the discharge hood (enclosed only) Rust-proof fasteners with nylon washers to protect finish High performance sound-absorbing material Gasketed doors Stamped air-intake louvers Air discharge hoods for radiator-upward pointing Stainless steel lift off door hinges Stainless steel lockable handles Rhino Coat - Textured polyester powder coat Engine Electrical System Battery charging alternator Battery Cables Battery Tray Solenoid activated starter motor Rubber-booted engine electrical connections CONTROL SYSTEM Control Panel Digital H Control Panel - Dual 4x20 Display Programmable Crank Limiter 7-Day Programmable Exerciser Special Applications Programmable PLC RS-232/485 All-Phase Sensing DVR Full System Status Utility Monitoring Low Fuel Pressure Indication 2-Wire Start Compatible Power Output (kw) Power Factor kw Hours, Total & Last Run Real/Reactive/Apparent Power All Phase AC Voltage All Phase Currents Oil Pressure Coolant Temperature Coolant Level Engine Speed Battery Voltage Frequency Date/Time Fault History (Event Log) Isochronous Governor Control Waterproof/sealed Connectors Audible Alarms and Shutdowns Not in Auto (Flashing Light) Auto/Off/Manual Switch E-Stop (Red Mushroom-Type) NFPA110 Level I and II (Programmable) Customizable Alarms, Warnings, and Events Modbus protocol Predictive Maintenance algorithm Sealed Boards Password parameter adjustment protection Single point ground 15 channel data logging 0.2 msec high speed data logging Alarm information automatically comes up on the display Alarms Oil Pressure (Pre-programmable Low Pressure Shutdown) Coolant Temperature (Pre-programmed High Temp Shutdown) Coolant Level (Pre-programmed Low Level Shutdown) Low Fuel Pressure Alarm Engine Speed (Pre-programmed Over speed Shutdown) Battery Voltage Warning Alarms & warnings time and date stamped Alarms & warnings for transient and steady state conditions Snap shots of key operation parameters during alarms & warnings Alarms and warnings spelled out (no alarm codes)

SG130 Configurable Options ENGINE SYSTEM GENERATOR SET ENCLOSURE SG130 130 kw General Engine Block Heater Oil Heater Air Filter Restriction Indicator Stone Guard (Open Set Only) Engine Electrical System 10A UL float/equalized battery charger 2.5A UL battery charger Gen-Link Communications Software (English Only) Extended Factory Testing (3 Phase Only) Pad Vibration Isolators 150 MPH Wind Kit 2 Year Extended Warranty 5 Year Warranty 5 Year Extended Warranty Weather Protected Level 1 Sound Attenuation Level 2 Sound Attenuation Steel Enclosure Aluminum Enclosure 12 VDC Enclosure Lighting Kits Door Alarm Switch ALTERNATOR SYSTEM CIRCUIT BREAKER OPTIONS Alternator Upsizing Anti-Condensation Heater Tropical coating Permanent Magnet Excitation Main Line Circuit Breaker 2nd Main Line Circuit Breaker Shunt Trip and Auxiliary Contact Electronic Trip Breakers CONTROL SYSTEM 21-Light Remote Annunciator Remote Relay Panel (8 or 16) Oil Temperature Sender with Indication Alarm Remote E-Stop (Break Glass-Type, Surface Mount) Remote E-Stop (Red Mushroom-Type, Surface Mount) Remote E-Stop (Red Mushroom-Type, Flush Mount) Remote Communication - Modem Remote Communication - Ethernet 10A Run Relay Engineered Options ENGINE SYSTEM GENERATOR SET CONTROL SYSTEM Coolant heater ball valves Fluid containment pans ALTERNATOR SYSTEM Special Testing Battery Box ENCLOSURE Spare inputs (x4) / outputs (x4) - H Panel Only Battery Disconnect Switch 3rd Breaker Systems Motorized Dampers Rating Definitions Applicable for a varying emergency load for the duration of a utility power outage with no overload capability. (Max. load factor = 70%) Power ratings in accordance with ISO 8528-1, Second Edition dated 2005-06-01, definitions for Prime Power (PRP) and Emergency Power (ESP).

SG130 130 kw SG130 application and engineering data ENGINE SPECIFICATIONS General Cooling System Make Generac Cooling System Type Pressurized Closed Recovery Cylinder # 10 Water Pump Flow - gpm (lpm) 38 (144) Type V Fan Type Pusher Displacement - L (Cu In) 6.8 (414.96) Fan Speed (rpm) 2300 Bore - mm (in) 90.17 (3.55) Fan Diameter mm (in) 558 (22) Stroke - mm (in) 105.992 (4.17) Coolant Heater Wattage 1500 Compression Ratio 9:01 Coolant Heater Standard Voltage 120 V Intake Air Method Naturally Aspirated Number of Main Bearings 7 Connecting Rods Forged Cylinder Head Aluminum Fuel System Cylinder Liners No Fuel Type Natural Gas, Propane Vapor Ignition High Energy Carburetor Down Draft Pistons Aluminum Alloy Secondary Fuel Regulator Standard Crankshaft Steel Fuel Shut Off Solenoid Standard Lifter Type Overhead Cam Operating Fuel Pressure 11" - 14" H2O Intake Valve Material Steel Alloy Exhaust Valve Material Steel Alloy Hardened Valve Seats Yes Engine Electrical System System Voltage 12 VDC Lubrication System Battery Charging Alternator Standard Oil Pump Type Gear Battery Size See Battery Index 0161970SBY Oil Filter Type Full-flow spin-on cartridge Battery Voltage 12 VDC Crankcase Capacity - L (qts) 5.7 (6) Ground Polarity Negative ALTERNATOR SPECIFICATIONS Standard Model 390 Voltage Regulator Type Full Digital Poles 4 Number of Sensed Phases All Field Type Revolving Regulation Accuracy (Steady State) +/- 0.25% Insulation Class - Rotor H Insulation Class - Stator H Total Harmonic Distortion <5% Engine Governing Telephone Interference Factor (TIF) <50 Governor Electronic Standard Excitation Brushless Frequency Regulation (Steady State) +/- 0.25% Bearings Sealed Ball Coupling Flexibile Disc Prototype Short Circuit Test Yes

SG130 operating data POWER RATINGS Natural Gas Propane Vapor Single-Phase 120/240 VAC @1.0pf 117 kw Amps: 488 130 kw Amps: 543 Three-Phase 120/208 VAC @0.8pf 122 kw Amps: 423 130 kw Amps: 451 Three-Phase 120/240 VAC @0.8pf 122 kw Amps: 367 130 kw Amps: 391 Three-Phase 277/480 VAC @0.8pf 122 kw Amps: 183 130 kw Amps: 195 Three-Phase 346/600 VAC @0.8pf 122 kw Amps: 147 130 kw Amps: 156 SG130 130 kw STARTING CAPABILITIES (skva) skva vs. Voltage Dip 480 VAC 208/240 VAC Alternator kw 10% 15% 20% 25% 30% 35% 10% 15% 20% 25% 30% 35% Standard 130 116 174 232 290 348 406 87 131 174 218 261 305 Upsize 1 150 133 199 265 332 398 464 100 149 199 249 299 348 Upsize 2 200 187 280 373 467 560 653 140 210 280 350 420 490 FUEL CONSUMPTION RATES* Natural Gas ft 3 /hr (m 3 /hr) Percent Load 25% 603 (17.1) 50% 1033 (29.3) 75% 1395 (39.5) 100% 1722 (48.8) Propane Vapor ft 3 /hr (m 3 /hr) Percent Load 25% 237.3 (6.7) 50% 406.7 (11.5) 75% 549.1 (15.5) 100% 677.9 (19.2) *Fuel supply installation must accommodate fuel consumption rates at 100% load. COOLING Air Flow (inlet air combustion and radiator) ft 3 /min (m 3 /min) 5979 (169.3) Coolant Flow per Minute gpm (lpm) 48 (181.7) Coolant System Capacity gal (L) 6.3 (23.9) Heat Rejection to Coolant BTU/hr 500,080 Max. Operating Air Temp on Radiator ºF (ºC) 122 (50) Max. Ambient Temperature ºF (ºC) 104 (40) Maximum Radiator Backpressure in H 2 O 0.5 COMBUSTION AIR REQUIREMENTS Flow at Rated Power cfm (m3/min) 379 (10.7) ENGINE Rated Engine Speed rpm 3000 Horsepower at Rated kw** hp 189 Piston Speed ft/min (m/min) 2085 (635) BMEP psi 132 ** Refer to Emissions Data Sheet for maximum bhp for EPA and SCAQMD permitting purposes. EXHAUST Exhaust Flow (Rated Output) cfm (m 3 /min) 1206 (34.1) Maximum Recommended Back Pressure inhg 1.5 Exhaust Temp (Rated Output) ºF (ºC) 1250 (676.7) Exhaust Outlet Size (Open Set) in 2.5" I.D. Flex (No muffler) Deration Operational characteristics consider maximum ambient conditions. Derate factors may apply under atypical site conditions. Please consult a Generac Power Systems Industrial Dealer for additional details. All performance ratings in accordance with ISO3046, BS5514, ISO8528 and DIN6271 standards. All power ratings are +/- 5%.

SG130 130 kw SG130 dimensions and weights OPEN SET (Includes Exhaust Flex) L x W x H in (mm) 110.04 (2795) x 39.88 (1013) x 52.38 (1330) Weight lbs (kg) 2600 (1180) STANDARD ENCLOSURE L x W x H in (mm) 132.72 (3371.1) x 40.46 (1027.8) x 64.05 (1627) Weight lbs (kg) Steel: 3100 (1407) Aluminum: 2765 (1255) LEVEL 1 ACOUSTIC ENCLOSURE L x W x H in (mm) 154.13 (3914.9) x 40.46 (1027.8) x 64.05 (1627) Weight lbs (kg) Steel: 3350 (1520) Aluminum: 2850 (1292) LEVEL 2 ACOUSTIC ENCLOSURE L x W x H in (mm) 144.53 (3671) x 40.46 (1027.8) x 80.88 (2054.3) Weight lbs (kg) Steel: 3600 (1634) Aluminum: 2930 (1330) YOUR FACTORY RECOGNIZED GENERAC INDUSTRIAL DEALER Specification characteristics may change without notice. Please consult a Generac Power Systems Industrial Dealer for detailed installation drawings. Generac Power Systems, Inc. S45 W29290 HWY. 59, Waukesha, WI 53189 generac.com 2013 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Part No. 0K4288-A / Printed in U.S.A. 07/23/13