SPECIFICATIONS. Installation arrow must point downward Vertical Valve For top mounting.

Similar documents
Metal Orifice Assemblies

Miniature Stainless Steel Fittings and Screens

Table of Contents. Page. See Catalog and Product Updates on our Website

M-50/55 Series. Fixed setting flow switch with in-line flow

LEVEL SWITCH INTRODUCTION APPLICATIONS

Shuttle Type Switches For Moderate to High Liquid Flow Rates

MAGNETIC LEVEL GAUGES

Tuffy Liquid Level Switches

Tuffy Liquid Level Controls with Pneumatic Switch

LS200, LS200N, LS200NDVOR Series and L1100 Liquid Level Switches

ITT Conoflow Process Control Solutions

M-100 Series. Adjustable flow switch with right-angle flow

Control Valves & Valve Accessories

Mini 1. Compact High Flow 3-Way and 4-Way Pneumatic Directional Control Valves

Performance Data. Temperature Range. -20 o to 160 o F 26 Hg to 125 psi. C v Flow Rate (scfm) Fill Time Exhaust. Port.

Balanced Valve Series Multi-Purpose Direct-Acting Solenoid Valves

COMPANY. Pneumatic Flow Meters Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:PNEUMAN082516

JIS symbols used in this catalog are old symbols following JISB0125-1: Refer to JISB0125-1: 2007 or JFPS2011: 2006 for new symbols.

Model 3200 Liquid Level Controller

Fundamentals of Flow Measurement

WDV-2 2-way normally closed poppet with air pilot. When valve closes a spring biased internal piston draws back a small volume on outlet side (approx.

Balanced Valve Series Multi-Purpose Direct-Acting Solenoid Valves

Miniature Pneumatic Solenoid Valve

Mallard. Model 3200 Liquid Level Controller. Features

Dymension SG Manifold Valves Using Direct Mount Manifold Technology

Temperature Sensor Series

Section 2 Proportional Quick Exhaust

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, IN 46361, U.S.A. Fax: 219/

The Discussion of this exercise covers the following points:

Technical Principles of Valves

Model 3201 Liquid Level Controller

Refinery Supply Company, Inc.

Chemical Injection Pumps and Products

COMPANY. Flow Rate Alarms Installation, Operating & Maintenance Manual

MODIFICATIONS AVAILABLE - MADE TO ORDER - CONSULT OUR FACTORY. (MINIMUM ORDER MAY BE REQUIRED.)

Valves, Fittings, and Manifolds Catalog. We make things MOVE

KENCO Oil Level Controllers are designed to maintain the running oil level in the crankcase of stationary engines, compressors and mechanical

Miniature Pneumatic Solenoid Valve

Series Cantilever Liquid Level Control

M-200 Series. High flow, Adjustable flow switch with right-angle flow

3-Way. Direct Acting & Pilot Operated Quick Exhaust Valves 1/4" - 3/8" NPT. General Description: Applications: Electrical Characteristics:

CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE*

UNIVERSAL. Flow Monitors Inc. INSITE Series PX - IS - TX Flow Rate Indicators and Switches

KOBOLD SV FLOWMETER/SWITCH. User Instructions

Chemical Injection Pumps and Products

QPV1 Electronic Pressure Regulator INSTALLATION AND MAINTENANCE INSTRUCTIONS

BYPASS ROTAMETERS FOR MEASURING RATE OF FLOW IN LARGE PIPELINES

Series: hydraulic-type control in pneumatic machinery

Series 11 Miniature Pneumatic Solenoid Valve 15mm Solenoid Valve

Mid-West Instrument. Diaphragm Type Differential Pressure Gauge & Switch Model 130. Shown here with Range 0-5 H2O

ball valves General Purpose Ball Valves

Accessories. Section Outline

Flow Switches INTRODUCTION

Flow Switches INTRODUCTION

Intelligent Positioner

M-100 Adjustable flow switch with right-angle flow

WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP

Series 1200A Magnetic Level Gauges, Transmitters and Switches

Ball Valves Pressures to 21,000 psi

KNOCK CYLINDERS CONTENTS ACTUATORS GENERAL CATALOG. Caution KNOCK CYLINDERS

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

Valve Reference C5. Valve Reference C6. 4-Way. 4-way direct acting

OPERATING AND MAINTENANCE MANUAL

Jo-Bell Products. DIVISION OF DALNOR SYSTEMS, INC Sierra Vista Drive Carlsbad NM, Phone: Fax:

BASIC IN-LINE LIQUID FLOW RATE MONITORS. Data Sheet No. B-699. Select from aluminum, brass or stainless steel to meet system and liquid requirements.

RS85 Vibrating fork level switch

M-200X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

The H Series Leak-Proof, High-Pressure Valves Versa Products Company has been supplying high quality pneumatic and hydraulic directional control valve

Solenoid valve. Solenoid Coil

Hi-Cyclic Magna-Cycle Valves

aero 2 -IOM aero 2 ACTUATOR - INSTALLATION, OPERATION & MAINTENANCE MANUAL

DIMENSIONS. Oil Capacity = 14.6 oz Maximum Fluid Temperature = 140 F Inlet Thread = 1/2 F Discharge Thread = 3/8 F

EI, EIO INTRINSICALLY SAFE VALVES

NCP/NCB/NCS. Magnetic Float Switches. for Liquids

KENCO ENGINEERING COMPANY

Miniature Inert PTFE Isolation Valves. Physical Properties Electrical Performance Characteristics

Switches for Pressure to 8000 psig, Vacuum, Differential, or Level Control with General Purpose, Watertight or Explosion-Proof Enclosures

Programmable Logic Controller. Mat Nor Mohamad

3/8 & 1/2 NPT. 4-Way - 5 Ported - 2 Position - Type 2 Use on all 4 Way - 2 Position applications

ES, ESO SERIES VALVES ES, ESO SERIES COMPACT VALVES. 210 Clippard Instrument Laboratory, Inc

RCM - Direct Reading Flowmeters

Toggle Valve s. OG, 1G, and 92 Series. Manual and pneumatically actuated models. Straight, angle, and cross body patterns

Space Saver. Space Saver Actuators. Air Actuated 0700 Series

ua ir e CONTROL VALVES Clippard Minimatic miniature valves and associated products have evolved into a widely used system of fluid power control devic

FEATURES APPLICATIONS OPERATING PRINCIPLE FOR OIL LEVEL CONTROLLERS OPERATING PRINCIPLE FOR OIL LEVEL SWITCHES

VAL /4" to 2" Solenoid Pilot Actuated 2/2, 3/2, & 4/2 Inline Valves. Solenoid pilot operated spring return inline valves with nonlocking

1 of 6. Prosdata Engineering Sdn. Bhd. Marine and Offshore Applications PRODUCT OVERVIEW

7FA. Team Power Services. Local Sales & Service. Industry Leader. Inventory Management. Your Total Solution Supplier for Power Generation

Mini Magnetic Float Type Level Switch

Becker Precision Equipment

XMV 3400 RPM D VERSION 1 WITH GAS ENGINE FLANGE DIMENSIONS

Combi2 TTW Models (CSW2TW, CDW2TW)

Electromechanical Level Control

Check Valve AP64 P.149. Vacuum Generator Vacuum Generator Module Vacuum Generator Module AP7 & 70 AP71 AP72. Flow Switch Flow Switch (For high flow)

Check Valves BALL TYPE

PNEUMATIC MARINE PRODUCTS FOR PROPULSION CONTROL

GW MKIII DELUGE VALVE - ALUBRONZE EXTERNAL RESET, PNEUMATIC


MULTI SLIDERS CONTENTS

Baumann Pneumatic Pressure Controller (for Industrial and Sanitary Applications)

Transcription:

PNEUMATIC FLOAT VALVE DESCRIPTION The Magnetic is an air sensor for detecting liquid level inside a vessel. The float mechanism mounted within the vessel operates a ceramic coated magnet. As the float moves it pivots the magnet. A magnetically actuated sensor on the outside of the solid metal housing reacts to the inner magnet movement. The movement shifts a 3-way air valve. Both side mounted and top mounted valves are available either as normally closed or normally open. FEATURES Explosion Proof No electrical hazard For vented or non-vented vessels Stainless steel float mechanism Side mounting or top mounting selection 3-way pneumatic valve Actuation indicator on 3 way valve Magnetic coupling-float to valve Minimum air usage SYMBOLS Normally Closed Normally closed float valves are "off" (no output) when float is low. Air signal is "on" when float is raised. Normally Open Normally open float valves are "on" when float is low. Air signal is "off" when float is raised. FLOAT AND BODY Temperature Limit 0 F Pressure Limit 00 psig Minimum Specific Gravity 0.5 SG Wetted Materials Brass Body; 30 SS, 304 SS, Ceramic Stainless Steel Body; 303 SS, 30 SS, 304 SS, Ceramic Installation Horizontal Valve For side mounting to vessel, Installation arrow must point downward Vertical Valve For top mounting. PNEUMATIC SENSOR Fluid Media Clean compressed air or inert gases, filtration < 40 microns Operating Pressure 30 to 00 psig Operating Temperature 35 to 40 F Valve Connections For 3/3" ID tubing (.5 mm) Air Supply Port # Output Port # Vent Port #3 Valve Operation The magnetically actuated valve is 3 way. The valve changes position in response to the float movement. Actuated Flow Path De-Actuated Flow Path Port # - Port # Port #3 - Port # (Blue Indicator Extended) (Blue Indicator Retracted) Actuation Indicator /6" diameter/blue Indicator extends outward (approximately /6" stroke) when port # is passing to port #. Air Flow No continuous air flow usage. Air Valve Orifice.080" diameter Materials of Construction Brackets Anodized Aluminum Switch Body Plastic Connection Barbs Brass Deadband Change in liquid level between valve actuation and deactuation. Horizontal models approximately /" Vertical models approximately /4" Horizontal float valve for side mounting to vessel. operates air valve on outside of vessel. Normally closed or normally open. SS Thread Solid Metal Body Ceramic Coated Magnet Magnetic Sensor Air Connections mechanism is contained inside a solid metal body. The air valve is located outside the metal body and is magnetically actuated. Vertical float valve is mounted on top side of closed or vented vessels. Normally closed or normally open versions available. Fax (03) 6-833 e-mail ca@okcc.com Mailing Address P.O. Box Q Trumbull, CT 066 Toll Free Phone (800) 533-385 O'Keefe Controls Co. 007 All Rights Reserved CT Phone (03) 6-67 website www.okcc.com Location 4 Maple Drive Monroe, CT 06468

PNEUMATIC FLOAT VALVE HORIZONTAL FLOAT VALVE SIDE MOUNTING VERTICAL FLOAT VALVE TOP MOUNTING Normally Closed Signal On Rising Level Normally Closed Signal On Rising Level 6-7/8"" NOT INCLUDED NOT INCLUDED OKC-53 Optional 7-/6" " Dia. x " Lg. SYMBOL N.C. OKC-53 Optional " Dia. x " Lg. SYMBOL N.C. PART NUMBERS Catalog No. Body Installation State Max. Pressure OKC-536- Brass Side Mounting N.C. Stainless Steel 00 psig OKC-536- Stainless Steel Side Mountin N.C. Stainless Steel 00 psig OKC-570- Brass Top Mounting N.C. Stainless Steel 00 psig OKC-570- Stainless Steel Top Mounting N.C. Stainless Steel 00 psig OKC-50- Brass Side Mounting N.O. Stainless Steel 00 psig OKC-50- Stainless Steel Side Mounting N.O. Stainless Steel 00 psig OKC-7- Brass Top Mounting N.O. Stainless Steel 00 psig OKC-7- Stainless Steel Top Mounting N.O. Stainless Steel 00 psig HORIZONTAL FLOAT VALVE SIDE MOUNTING Normally Open Signal On Falling Level VERTICAL FLOAT VALVE TOP MOUNTING Normally Open Signal On Falling Level OKC-53 Optional NOT INCLUDED -7/8" " Dia. x " Lg. OKC-53 Optional 7-/6" 6-7/8" " Dia. x " Lg. SYMBOL N.O. NOT INCLUDED SYMBOL N.O. O Keefe Controls Co. O'Keefe Controls Co. 007 All Rights Reserved

LEVEL INDICATOR AND CONTROL APPLICATIONS Normally Closed Indicator Indicator Signal "On" (Port ) when level is high. Normally Open Normally closed float valve (side or top mounted). Output signal (port ) of level sensor is "on" when level is high. Output can actuate an indicator, pressure switch, air pilot power valve, etc. Can be used with High Level Indicator panel shown on page 4. Normally open float valve (side or top mounted). Output signal (port ) of level sensor is "on" when level is low. Output can actuate an indicator, pressure switch, air pilot power valve, etc. Can be used with Low Level Indicator panel shown on page 4. LEVEL CONTROL WIDEBAND LEVEL CONTROL NARROWBAND Valve Valve Normally Closed Normally Open Detented Air Valve Normally Open Two level sensors required; one normally closed for high level, one normally open for low level. The control automatically maintains the level between the location of the two sensors. Minimum "high/low" is approximately two inches. Maximum "high/low" is set by the location of the two sensors. Can be used with Wideband Level Control panel on page 4. One normally open float valve provides the control for narrowband level control. Level is maintained within approximately /". Output can actuate an air operated power valve for direct fill, or for control of an air operated pump through an air operated power valve. The output can be used with the Narrowband Level Control panel shown on page 4. O'Keefe Controls Co. 007 All Rights Reserved

To High To Low This panel is used for indication of level only. When a normally closed float valve is actuated by high liquid level the indicator shows "red". The indicator shows green when the float valve is not actuated. Part No. OKC-89F Includes inlet filter, regulator Part No. OKC-89 Filter, regulator and gage not Use the high level indicator panel with a normally closed float valve. OKC-536- OKC-570- OKC-536- OKC-570- This panel is used for indication of level only. When a normally open float valve is deactuated by low liquid level the indicator shows "red". The indicator shows green when the float valve is actuated by the liquid level. Part No. OKC-90F Includes inlet filter, regulator Part No. OKC-90 Filter, regulator and gage not Operation A pneumatic indicator panel Box Dimensions 4-/" x -7/8" x -5/8" Inlet Air Pressure to Regulator 50-5 psig Normal Pressure Setting 50-00 psig Pneumatic Indicator " diameter red/green Manual Control OFF/ON Toggle Valve Air Filtration Air should be dry and filtered to 5 microns Use the low level indicator panel with a normally open float valve. OKC-50- OKC-7- OKC-50- OKC-7- Form OK-4R WIDEBAND LEVEL CONTROL To Control Valve or Pump NARROWBAND LEVEL CONTROL To Control Valve or Pump To High To Low To Level Sensor WIDEBAND LEVEL CONTROL This panel is used for control of liquid between two levels. The control panel pilots a fill or drain valve, or controls a power valve that operates a pump. A normally closed float valve is used to sense the high level. A normally open float valve is used to sense the low level. Part No. OKC-9F Includes inlet filter, regulator Part No. OKC-37F (same as OKC-9F but configured for Pump Down operations.) OKC-9F panel indicator shows green after the high level is reached and continues to indicate green until the low level is reached. After the low level sensor is deactuated the indicator shows "red" until the high level sensor is actuated. (OKC-37F shows "red" during pump down.) When the panel indicator shows "green" the output signal is "off". When the panel indicator shows "red" the output signal is "on." NARROWBAND LEVEL CONTROL This panel is used for control of liquid level over the deadband of the pneumatic float valve (approximately /4" to /"). The control panel pilots a fill or drain valve that operates a pump. A normally open float valve is used. The output control is "on" (indicator red) when the level is low and is "off" when the level is high (indicator green). Part No. OKC-9F Includes inlet filter, regulator Part No. OKC-9 Filter, regulator and gage not The output signal can also be used as a remote indicator signal to operate a visual indicator or a sonic alarm. Use as follows: Low Level Alarm use a normally open float valve High Level Alarm use a normally closed float valve O'Keefe Controls Co. 007 All Rights Reserved Operation A pneumatic control panel Box Dimensions 4" x 4" x -5/8" Inlet Air Pressure to Regulator 50-5 psig Normal Pressure Setting 50-00 psig Pneumatic Indicator " diameter red/green Manual Control OFF/ON Toggle Valve Air Filtration Air should be dry and filtered to 5 microns Output Air Signal 50-00 psig (same as regulator pressure setting)