PHASED OUT. LED light engine / OLED LED linear / area. Umodule STARK LLE umodule LLE ADVANCED

Similar documents
LED light engine / OLED LED linear / area. Umodule STARK LLE-G CLASSIC STARK LLE

LED light engine / OLED LED linear / area. Umodule STARK LLE-G CLASSIC EM STARK LLE

PHASED OUT. LED / OLED Light Engine LED linear / area. Umodule STARK LLE STARK LLE

PHASED OUT. LED light engine / OLED LED linear / area. Module LLE G3 16x140mm 325lm ADV, LLE G3 16x280mm 650lm ADV Modules LLE ADVANCED

LED light engines LED linear / area. Module STARK QLE G3 SELECT Modules QLE EXCITE

PHASED OUT. LED light engine / OLED LED compact. Module STARK CLE , CLE CLASSIC Modules CLE

LED light engine / OLED LED compact

PHASED OUT. LED light engine / OLED LED compact. Module STARK CLE CLASSIC / CLE CLASSIC Modules CLE

LED light engine / OLED LED linear / area

LED light engines LED linear / area

LED modules LED linear / area

LED light engine / OLED LED linear / area. Module STARK LLE PREMIUM Modules LLE

LED light engine / OLED LED linear / area. Module LLE PREMIUM CRI90 LLE PREMIUM

LED modules LED linear / area

LED light engines LED linear / area

LED light engine / OLED LED linear / area

PHASED OUT. LED light engine / OLED LED linear / area. Module QLE G1 488x239mm 2500lm ADV-SE Modules QLE

LED light engines LED linear / area

Tunable White LED linear / area. Module LLE G2 PREMIUM LLE PREMIUM

PHASED OUT. LED light engine / OLED LED compact. Module CLE G2 190mm 1500lm ADV EM Modules CLE

LED light engine / OLED LED compact

LED light engines LED linear / area

LED light engines LED linear / area

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule STARK QLE CLASSIC EM umodule STARK QLE PHASED OUT. Ordering data.

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC EM STARK CLE

LED modules LED linear / area

PHASED OUT. LED light engine / OLED LED compact. Umodule STARK DLE GEN2 CLASSIC STARK DLE

LED modules LED flexible. Module LLE FLEX G1 8mm EXC Modules LLE FLEX EXCITE

LED light engine / OLED LED compact. Umodule SLE G4 FASHION EXC

LED light engine / OLED LED compact. Umodule STARK CLE 360 CLASSIC EM STARK CLE

PHASED OUT. LED light engine / OLED LED compact. Module SLE G5 ART EXC Modules SLE EXCITE

LED light engine / OLED LED compact. Umodule EOS P214-4 umodule EOS

Tunable White LED linear / area

SLA DC. LED light engines ready2apply. Module SLA DC G2 50mm SNC Modules SLA ESSENCE

LED light engines ready2apply. Engine SLA AC G2 50mm SNC Engine SLA ESSENCE

Emergency lighting units EM LED Light Engines. Module EM-ES 08/10/12 Mk2 EM LED linear / area

U LED modules, converters and systems SIGNAGE. Uengine IMAGE SELECT

Uengine COOL door for integration uengine COOL

LEDtape 800 TW Tunable White K CRI>90

Applications. Shelf Lighting General Lighting Food Lighting Accent Lighting. Electrical Properties. Photometric Code. Typ.

Emergency lighting units EM LED Light Engines. EM ready2apply BASIC 1 2 W EM ready2apply

Applications. Food Lighting Shelf Lighting Accent Lighting Ambient Lighting. Electrical Properties

PRODUCT DESCRIPTION TECHNICAL DATA. Dimmable 0.1% - 100% Operating temperature - 30 C +45 C LED per meter 60 Pitch distance Cutting Length (C)

Applications. General Lighting Office Lighting Food Lighting Accent Lighting. Electrical Properties

Emergency lighting units EM LED Light Engines

Adjustable Adjustable Large Adjustable Deep. Deep / Deep IP44 / Deep Adjustable Deep Gold Deep Black Gold. IP44 Square Square Adjustable / 1-2-3

LED control gear Compact fixed output

FL ballasts Electronic fixed output PC BASIC, 4 28 W PC BASIC

Applications. Accent Lighting Ambient Lighting Display Lighting Shelf Lighting. Electrical Properties

LED Driver Linear / area dimming

LED Driver Linear / area fixed output

Emergency lighting units EM powerled

LED MODULES. Comfort COB Residential, Retail and Industrial Lighting COMFORT COB 500 LM TO 11,000 LM

LED BUILT-IN MODULES. LUGA C 2016 HiCRI COB modules for lumen packages from 1500 to 4500 lm. LUGA C 2016 HiCRI 1500 LM TO 4500 LM.

LED Driver Compact fixed output

LED Driver Compact fixed output

Emergency lighting units EM powerled

LED Driver Linear / area fixed output industry. Driver LCI 100W 350mA 900mA TOP INDUSTRY sl TOP series

Emergency lighting units EM converterled

Emergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series

Emergency lighting units EM converterled

LED Driver Linear / area fixed output industry. Driver LCI 65W 150mA 400mA TOP INDUSTRY sl TOP series

Emergency lighting units EM converterled

Emergency lighting units EM converterled. EM converterled BASIC 50 V BASIC series

Emergency lighting units EM converterled. EM converterled BASIC 200 V BASIC series

Emergency lighting units EM converterled

LED LINE SMD KIT GEN. 2

LED BUILT-IN MODULES. LED Module Easy 28 Industrial and Hospitality Lighting EASY 28 3,500 LM TO 14,000 LM EASY 28 INDUSTRIAL AND HOSPITALITY LIGHTING

BUILT-IN LED LIGHTING MODULES

LED Office Solutions

LED Driver Linear / area dimming industry. Driver LC 150W mA IND sl EXC EXCITE series

Emergency lighting units EM converterled

LED MODULES. LUGA Shop Gen. 5 Retail and Industrial Lighting LUGA SHOP GEN LM TO 20,000 LM LUGA SHOP GEN. 5 RETAIL AND INDUSTRIAL LIGHTING

Start Waterproof LED G3 fixed output START WATERPROOF LED G3 1500MM T 4K

Emergency lighting units EM powerled

Emergency lighting units EM powerled

Description: RX-ALF28T Series Waterproof LED module, Ultra-Slim Light Box direct type light source - can be continuously

LED MODULES. LUGA Shop Gen. 6 Retail and Industrial Lighting LUGA SHOP GEN LM TO 15,000 LM LUGA SHOP GEN. 6 RETAIL AND INDUSTRIAL LIGHTING

VMU048012LP8xxA 5.5 LP-LINEARHO DC MODULE, 480mA MAX CURRENT

Emergency lighting units EM powerled. EM powerled BASIC CLE Emergency lighting LED Driver

LED FlatPanel Gen. 2. LED FlatPanel Gen. 2 ULTRA FLAT LIGHT PANEL. LED FlatPanel Gen. 2

VMU080030LP8xxA 22 LP-LINEARHO DC MODULE, 800mA MAX CURRENT

VMU140055LP8xxC 46 LP-LINEARHO DC MODULE, 1400mA MAX CURRENT

Fortimo LED Line Gen3

VMU240095LP8xxA 44 LP-LINEARHO DC MODULE, 2400mA MAX CURRENT

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

Retail and Hospitality. Module SLE ADV Generation 7 For remarkably efficient and durable spotlight lighting

DATA SHEET. GLV92C50501 Series. Part of the simpleled Program v1 P-1

FL ballasts Electronic fixed output. PC BASIC sl, 4 28 W PC BASIC

Typ. CRI. SDCM Module P [W]

TMU140055CL8xxA 44 LINEARHO DC MODULE, 1400mA MAX CURRENT

TMU125050CL8xxA 22 LINEARHO DC MODULE, 1250mA MAX CURRENT

THE PERFECT REPLACEMENT

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

Experience bright and vivid colors

FL ballasts Electronic fixed output PC T8 TEC, W PC TEC T8

PrevaLED Cube G2. Product family datasheet. Spot-, Down- and Wallmount Light Engines and Modules

FL ballasts Electronic fixed output. PC T5 TOP lp, W PC TOP T5

XOOCOVE IP40. The optimum lighting solution with special mounting accessories for a wide range of cove applications

Experience bright and vivid colors

Transcription:

Ideal for linear and panel lights Luminous flux range 1, up to 1,300 lm LED system solution with outstanding system efficiency up to 111 lm/w, consisting of linear LED modules and dimmable LED Driver LCAI 080/0350 Efficacy of the module up to 124 lm/w High colour rendering index CRI > 80 Small colour tolerance MacAdam 3 4 Small luminous flux tolerances Colour temperature 2,700 K Perfectly uniform light, even if several LED modules are used together in a line Push terminals for quick and simple wiring of LED module to LED module Simple installation (e.g. screws) Long life-time: 50,000 hours 5-year guarantee Technical data Beam characteristic 120 Ambient temperature ta -30... +45 C Typ. tp point 65 C Risk group (EN 62471:2008) 0 Type of protection IP00 È Standards, page 5 Colour temperatures and tolerances, page 8 Umodule STARK LLE 24-280-1250 umodule LLE ADVANCED 2.5 3 280 125 125 Ø4 125 (77.5) Type Article number Colour temperature Packaging Weight per carton pc. Umodule STARK-LLE24-1250-827-CLA 89800382 2,700 K 50 pc(s). 0.023 kg Specific technical data Type 5 Photometric Typ. luminous Typ. luminous Typ. Min. forward Max. forward Typ. power Efficacy Efficacy Efficacy Colour Energy flux at flux at forward voltage at voltage at consumption at of the module of the module of the system rendering classifica- code tp = 25 C 1 tp = 65 C 1 current 123 tp = 65 C tp = 25 C tp = 65 C 1 at tp = 25 C at tp = 65 C at tp = 65 C index CRI tion Operating mode HE at 300 ma STARK-LLE24-1250-827-CLA 827/348 1,160 lm 1, lm 300 ma 27.5 V 38.5 V 9.8 W 114 lm/w 111 lm/w 102 lm/w > 80 A+ Operating mode HO at 350 ma STARK-LLE24-1250-827-CLA 827/348 1,300 lm 1,230 lm 350 ma 28.2 V 39.2 V 11.6 W 109 lm/w 107 lm/w 98 lm/w > 80 A+ 1 Tolerance range for optical and electrical data: ±10 %. 2 Max. permissible repetitive peak current 6,500 K: 480 ma; 2,700 K: 600 ma. 3 Max. permissible surge current 6,500 K: 1 A, duration max. 10 µs; 2,700K: 0.8 A, duration max. 10 ms. 4 Central measurement over the complete module. 5 HE... high efficiency, HO... high output. 1.6 (15) 24 6.1 www.tridonic.com 1

ACCES- SORIES LINEAR COVER for LLE 24 Protection against direct touch for non-selv applications Fast snap on mounting on to LLE 24 with clips or plastic washers High transmission: transparent 94 %, semi-transparent 87 %, diffuse 76 % Made of PMMA Tolerances: ± 1 mm for 597 mm length (ends finished), + 20 mm for 1,200 / 1,500 / 1,600 / 1,800 mm legth (ends raw) LINEAR COVER SY 28.6±0.3 1.3±0.1 24+0.5/-0.4 35±0.5 R17.5 1.8 Type Article Packaging Weight Colour Length number carton per pc. LINEAR COVER SY Transparent 1600mm 28000338 Transparent 1,600 mm 12 pc(s). 0.272 kg LINEAR COVER SY Frosted 1800mm 28000437 Semi-transparent 1,800 mm 12 pc(s). 0.308 kg LINEAR COVER SY Frosted 1600mm 28000339 Semi-transparent 1,600 mm 12 pc(s). 0.272 kg LINEAR COVER SY Frosted 1500mm 28000435 Semi-transparent 1,500 mm 12 pc(s). 0.244 kg LINEAR COVER SY Frosted 1200mm 28000422 Semi-transparent 1,200 mm 12 pc(s). 0.205 kg LINEAR COVER SY Frosted 597mm 28000340 Semi-transparent 597 mm 12 pc(s). 0.102 kg LINEAR COVER SY Diffuse 1800mm 28000438 Diffuse 1,800 mm 12 pc(s). 0.308 kg LINEAR COVER SY Diffuse 1600mm 28000341 Diffuse 1,600 mm 12 pc(s). 0.272 kg LINEAR COVER SY Diffuse 1500mm 28000436 Diffuse 1,500 mm 12 pc(s). 0.257 kg LINEAR COVER SY Diffuse 1200mm 28000434 Diffuse 1,200 mm 12 pc(s). 0.205 kg LINEAR COVER SY Diffuse 597mm 28000342 Diffuse 597 mm 12 pc(s). 0.102 kg www.tridonic.com 2

ACCES- SORIES ENDCAP for LLE 24 Fast snap on mounting (sheet thickness 0.5 1.0 mm), for drilling hole 4 mm Made of Polycarbonat ACCES- SORIES Linear lens for LLE 24 Available in 60 and 90 light distribution Protection against direct touch for non-selv applications Fast snap on mounting on to LLE 24 with clips or plastic washers High transmission: semi-transparent 97 % Linear lense made of PMMA Tolerances: ± 20 mm for 1,600 mm legth (ends raw) ACL ENDCAP LLE24 PUSH-FIX R19.2 R10.5 30.3 12 5 20.0 38.4 Article Type Colour Packaging carton Weight per pc. number ACL ENDCAP LLE24 PUSH-FIX 28001037 White 480 pc(s). 0.003 kg LINEAR LENS 13.12 60 90 24+0.2/-0.4 32±0.5 10.55 24+0.2/-0.4 32±0.5 Type Article Packaging Weight Colour Length number carton per pc. ACL LINEAR LENS 24x1600mm 60 28000953 Halbtransparent 1,600 mm 21 pc(s). 0.261 kg ACL LINEAR LENS 24x1600mm 90 28000955 Halbtransparent 1,600 mm 21 pc(s). 0.221 kg 6 www.tridonic.com 3

Clip for fixation of LED modules with 4.3 mm holes Fast snap on mounting (sheet thickness 0.5 1.0 mm) For drilling hole 4 mm Clip made of Polycarbonat 1 Minimum sales quantity 500 pcs. ACCES- SORIES CLIP 4.3mm 2.2±0.05 ø9 ø5.3 1.2 ø3.6 Type Article number Colour Packaging bag 1 Weight per pc. ACL CLIP 4.3mm PUSH-FIX 28001036 White 500 pc(s). 0.001 kg 7.4 www.tridonic.com 4

Standards EN 62031 EN 62471 EN 61347-1 EN 61547 EN 55015 Photometric code Key for photometric code, e. g. 830 / 349 1 st digit 2 nd + 3 rd digit 4 th digit 5 th digit 6 th digit Lumen maintanance after 25% Code CRI McAdam after of the life-time (max.6000h) Colour temperature in McAdam 25% of the Code Remaining lumen 7 67 76 Kelvin x initial life-time 7 70 % 8 77 86 (max.6000h) 8 80 % 9 87 90 9 90 % Thermal design and heat sink The rated life of u products depends to a large extent on the temperature. If the permissible temperature limits are exceeded, the life of the umodule STARK LLE will be greatly reduced or the umodule STARK LLE may be destroyed. tc point, ambient temperature and life-time The temperature at tp reference point is crucial for the light output and life-time of a u product. For umodule STARK LLE a tp temperature of 65 C has to be complied in order to achieve an optimum between heat sink requirements, light output and life-time. Compliance with the maximum permissible reference temperature at the tc point must be checked under operating conditions in a thermally stable state. The maximum value must be determined under worst-case conditions for the relevant application. The tc and tp temperature of LED modules from Tridonic are measured at the same reference point. Mounting instruction None of the components of the umodule STARK LLE (substrate, LED, electronic components etc.) may be exposed to tensile or compressive stresses. Max. torque for fixing: 0.5 Nm. The LED modules are mounted onto a heat sink with min. 2 screws per module. In order not to damage the modules only rounded head screws and an additional plastic flat washer should be used. Chemical substance may harm the LED module. Chemical reactions could lead to colour shift, reduced luminous flux or a total failure of the module caused by corrosion of electrical connections. EOS/ESD safety guidelines The device / module contains components that are sensitive to electrostatic discharge and may only be installed in the factory and on site if appropriate EOS/ESD protection measures have been taken. No special measures need be taken for devices/modules with enclosed casings (contact with the pc board not possible), just normal installation practice. Please note the requirements set out in the document EOS / ESD guidelines (Guideline_EOS_ESD.pdf) at: http://www.tridonic.com/esd-protection Heat sink values Umodule STARK LLE ta tp Forward current Rth, hs-a Cooling area 25 C 65 C 300 ma 6.0 K/W 111 cm² 25 C 65 C 350 ma 5.1 K/W 131 cm² 35 C 65 C 300 ma 4.5 K/W 149 cm² 35 C 65 C 350 ma 3.8 K/W 176 cm² 45 C 65 C 300 ma 2.9 K/W 227 cm² 45 C 65 C 350 ma 2.5 K/W 268 cm² Notes The actual cooling surface can differ because of the material, the structural shape, outside influences and the installation situation. Depending on the heat sink a heat conducting paste or heat conducting film might be necessary to keep the specified tp temperature. Materials which are used in LED applications (e.g. sealings, adhesives) must not produce dissolver gas. They must not be condensation curing based, acetate curing based or contain sulfur, chlorine or phthalate. Avoid corrosive atmosphere during usage and storage. www.tridonic.com 5

Thermal behaviour storage temperature -40... +85 C operating temperature ta -30... +45 C tp (at typ. current) 65 C tc max. (at typ. current) 85 C max. humidity 0... 80 % * not condensating If [ma] 400 300 200 0 0 10 20 30 40 50 60 70 80 90 tc [ C] Life-time, lumen maintenance and failure rate The light output of an LED Module decreases over the life-time, this is characterized with the L value. L70 means that the LED module will give 70 % of its initial luminous flux. This value is always related to the number of operation hours and therefore defines the lifetime of an LED module. As the L value is a statistical value and the lumen maintenace may vary over the delivered LED modules. The B value defines the amount of modules which are below the specific L value, e.g. L70B10 means 10 % of the LED modules are below 70 % of the inital luminous flux, respectivly 90 % will be above 70 % of the initial value. In addition the percentage of failed modules (fatal failure) is characterized by the C value. The F value is the combination of the B and C value. That means for F degradation and complete failures are considered, e.g. L70F10 means 10 % of the LED modules may fail or be below 70 % of the initial luminous flux. Lumen maintenance for Umodule STARK LLE-24-280-1250 Forward current 300 ma 350 ma tp L90 / F10 temperature L90 / F50 L80 / F10 L80 / F50 L70 / F10 L70 / F50 55 C 15,000 h 22,000 h 31,000 h 46,000 h 49,000 h > 60,000 h 65 C 12,000 h 18,000 h 25,000 h 38,000 h 40,000 h > 60,000 h 75 C 10,000 h 15,000 h 21,000 h 31,000 h 33,000 h 49,000 h 55 C 12,000 h 18,000 h 26,000 h 39,000 h 42,000 h > 60,000 h 65 C 10,000 h 15,000 h 21,000 h 32,000 h 34,000 h 51,000 h 75 C 8,000 h 12,000 h 17,000 h 26,000 h 28,000 h 41,000 h Selection of the LED Driver umodule STARK LLE can be operated either from SELV LED Drivers or from LED Drivers with LV output voltage. umodule STARK LLE are basic isolated against ground and can be mounted directly on earthed metal parts of the luminaire also when used in conjunction with the LED Driver LCAI 080/0350. In this case the light emitting side of the module has to be protected against direct touch (test finger). This is typically achieved by means of a non removable light distributor over the module. Electrical supply/choice of LED Driver umodule STARK LLE from Tridonic are not protected against overvoltages, overcurrents, overloads or short-circuit currents. Safe and reliable operation can only be guaranteed in conjunction with a LED Driver which complies with the relevant standards. The use of uconverter from Tridonic in combination with umodule STARK LLE guarantees the necessary protection for safe and reliable operation. If a LED Driver other than Tridonic uconverter is used, it must provide the following protection: Short-circuit protection Overload protection Overtemperature protection Wiring in + L N umodule STARK LLE must be supplied by a constant current LED Driver. Operation with a constant voltage LED Driver will lead to an irreversible damage of the module. Wrong polarity can damage the umodule STARK LLE. If umodules LLE are wired in parallel and a wire breaks or a complete module fails then the current passing through the other module increases. This may reduce its life considerably. In addition there can be slight differences in light output caused by tolerances. Wiring examples + Uconverter LCAI 80 W 350 ma Uconverter LCAI 50 W 1050 ma + N L out + + + + + + + Wiring type and cross section The wiring can be solid cable with a cross section of 0.2 to 0.75 mm². For the push-wire connection you have to strip the insulation (6 7 mm). wire preparation: 0.2 0.75 mm² 6 7 mm Inserting stranded wires / removing wires by lightly pressing on the push button. www.tridonic.com 6

Relative forward voltage and relative luminous flux Rel. luminous flux [%] Rel. forward voltage [V] The diagrams are based on statistic values. The real values can be different. Optical characteristics Umodule STARK LLE The optical design of the umodule STARK LLE product line ensures optimum homogenity for the light distribution. Light distribution relative intensity Iv/Iv, max 150 125 75 50 25 0 0 50 150 200 250 300 350 400 Operating current [ma] 1,10 0,55 0,00-0,55-1,10-1,65-2,20 25 35 45 55 65 75 85 tc [ C] 80 60-60 40-50 -40-30 -20-10 0 20 80 10 20 30 40 50 60 70 rel. luminous flux [a.u.] Forward current [ma] 1,10 1,00 0,90 0,80 0,70 0,60 0,50 25 35 45 55 65 75 tc [ C] 400 350 300 250 200 150 30,5 31,0 31,5 32,0 32,5 33,0 33,5 34,0 Forward voltage [V] 2700 / 6500 K The colour temperature is measured integral over the complete module. The single LED light points can have deviations in the colour coordinates within MacAdam 7. To ensure an ideal mixture of colours and a homogenious light distribution a suitable optic (e. g. PMMA diffuser) and a sufficient spacing between module and optic (typ. 4 cm) should be used. 85 34,5 0 - -80-60 -40-20 0 20 40 60 80 90 For further information see Design-in Guide, 3D data and photometric data on www.tridonic.com or on request. www.tridonic.com 7

Coordinates and tolerances according to CIE 1931 The specified colour coordinates are central measured by a current impulse with typical values of module and a duration of ms. The ambient temperature of the measurement is ta = 25 C. The measurement tolerance of the colour coordinates are ± 0.01. 2,700 K x0 y0 Centre 0.4586 0.4103 0,4300 0,4250 0,4200 0,4150 0,4 0,4050 0,4000 0,3950 0,3900 0,4400 0,4450 0,4500 0,4550 0,4600 0,4650 MacAdam Ellipse: 3SDCM 0,4700 0,4750 0,4800 norm. intensity [%] 80 60 40 20 0 380 420 460 500 540 580 620 660 700 740 780 wave length [nm] www.tridonic.com 8