PowerCommand 500/550 Remote Monitoring System

Similar documents
Remote Monitoring System

POWERCOMMAND CLOUD REMOTE MONITORING SYSTEM

PowerCommand iwatch Wireless

Diesel generator set B3.3 series engine 44 kva - 66 kva 50 Hz 40 kw - 60 kw 60 Hz

Diesel Generator Set S3.8 Series Engine

PowerCommand Paralleling Systems. Robust Paralleling System Solutions For Reliable Performance

GTEC Transfer switch open transition

Transfer switch GTEC open or delayed transition

PowerCommand. ModLon II Gateway. Specifications. ModBus LON Converter

Digital Controls Technology

Transfer switch OTEC open or delayed transition

PowerCommand 2.2 control system

OHPC/CHPC Transfer Switches

Powering telecoms, keeping people connected. Power generation engineered for telecoms. Our energy working for you. TM

PowerCommand 3300 Control Panel. Our Energy Is Working For You.

Cummins delivers reliable power in one easy-to-use system

Digital generator set control PowerCommand 3100

SNMP dedicated to ORVALDI Solar Infini

Digital controls. PowerCommand digital control technology

PowerBox C1000 D2R and C1250 D2R. Reliable, flexible power systems engineered to provide cost-effective power even in the most remote environments

Complete Power Systems. Accountability for Every Aspect of Onsite Power Delivery

Paralleling Equipment

PowerCommand 2.2 control system

Rental & Construction Power kva 50 Hz Dual Frequency. Our energy working for you.

Automatic Transfer Switches. Global

Transfer switch OTPC open, closed, or delayed transition

Ground fault indication relay - H550, H666, H667, H668

PowerCommand 1.2 control system

Mains. Great performances. Attractive coloured display. PLC functions inbuilt. Several I/O with possibility of expansion modules

PowerCommand 1.1 control system

Features and Benefits. Certifications

Gas Project Application Capabilities

Installation Instructions for the PowerCommand 3100 FT-10 Network Genset Communications Module (GCM) Kit

PowerCommand 2100 digital generator set control

OFF-GRID PV INVERTERS EssenSolar & Expert series. 1kW-5kW. Solution on Unstable or Remote Area without Utility

QSK60 Series Gas Powered Generator Sets

User s Manual. Suitable Products: Three phase grid tie inverter with energy storage Three phase off Grid inverter

Lean-Burn Gas Fueled Generator Sets

Cooled incubators (ST), laboratory refrigerators

Diesel generator set 4BT3.3 series engine

GTEC Transfer switch Open transition

StorEdge Wiring Guide & On Site Checklist - Europe, Australia & South Africa

MCS-BMS-GATEWAY STARTUP GUIDE Covers Model No. FPC-C35

Connect Series Accessories

QUANTUM LX CONTROL PANEL

Connect Series Accessories

There is a Certification menu option that indicates that the mobile APP, mobile device used were self-certified according to federal requirement.

Raption 50 Series. Instruction Manual

THYRO-PX SERIES DIGITAL THYRISTOR SCR POWER CONTROLLER UP TO 2900 AMPS

Dominion PX TM. Frequently Dominion PX TM Asked Frequently Asked Questions. General Questions

GENSET PRODUCTS 013 2

Installation Manual PowerBox Containers (20 & 40 )

Buildings. Product Name. THE SMART CHOICE FOR ENERGY SAVINGS. SmartVFD HVAC and BYPASS

ProtoNode FPC-N34 and FPC-N35

Intelligent DC UPS Module

MIC4 IGNITION CONTROLLER

Diesel generator set QSL9 series engine

ET9500 BEMS Interface Box Configuration Guide

EPAS Desktop Pro Software User Manual

Laboratory refrigerators

FT-10 Network Digital I/O Module Kits and

DRIVER DISPLAY DRIVER DISPLAYS CO-PILOT

HOS Mobile App Driver s Guide. pg 1

Installation and Programming Manual Part: Building Network Interface Card Product: 4100ES

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

Diesel generator set 6BT5.9 series engine

SolarPower. User Manual. Suitable Products: Three-phase grid-tie inverter with energy storage. Three-phase off-grid inverter

SolarPower. User Manual. Suitable Products: Three-phase grid-tie inverter with energy storage. Three-phase off-grid inverter

INTECH Micro 2300-RTD6

Energetic independence

Hi-Z USB Wireless. Introduction/Welcome

Industrial Renewable Energy. 4-Port 10/100/1000T 802.3at PoE+ Managed Ethernet Switch BSP-360. Quick Installation Guide

ValveLink SNAP-ON Application

Diesel generator set QSL9-G7 series engine

Spark-ignited generator set

Connection. 1. Diagnostic socket 2. Adaptor 3. Main cable 4. PC-MAX main unit 5. PC 6. Wireless adaptor

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: Dec., 2015 Version: 1.1

VIDA SUBSCRIPTION INSTRUCTION CONTENTS

SecureUPS On-Line 120V AC Output, 1300VA

PRODUCT PORTFOLIO. Electric Vehicle Infrastructure ABB Ability Connected Services

Decision-Makerr Paralleling System

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Generator Set Applications FT-10 Network Control Communications Module (CCM-G) Kit

Issue 2.0 December EPAS Midi User Manual EPAS35

Battery Care the new Battery Charger Philosophy Battery Charger and Battery Tester. Charge & Testing. Integrated Electronic Solutions

ZEPHYR FAQ. Table of Contents

ENGINEERED TO ORDER SOLUTIONS

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

LiDAT. Data transmission and tracking system for crawler cranes, duty cycle crawler cranes and deep foundation machines GPS / GLONASS GSM / GPRS

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

EVlink Charging Stations Commissioning Guide


DKG-109 AUTOMATIC MAINS FAILURE UNIT

OPERATION AND MAINTENANCE

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

engineered to order solutions

Est Battery Data Logger BDL3000

Honeywell CORE Drive FEATURES APPLICATION SPECIFICATION DATA

User manual Suppliers evaluation process

Transcription:

PowerCommand 500/550 Remote Monitoring System Complete remote monitoring of your power system The PowerCommand 500 series provides a convenient means of remotely monitoring generator sets, transfer switches, sensors and output controls. Users can access the remote monitoring device from any PC or Mac computer using a Microsoft Silverlight-enabled web browser; no additional software is required. Multiple users can monitor the power system equipment simultaneously. PowerCommand 500 series users can monitor generator set data, such as annunciator, alternator and engine data, as well as transfer switch data, such as source, load and switch connection status. Expandable I/O modules can provide additional monitoring and controlling capabilities. Features Communicates: PowerCommand 500/550 communicates to Cummins Power Generation controls (generator sets, transfer switches and expandable I/O modules) via Modbus. Legacy controls will require a LonWorks to Modbus converter PowerCommand Lon Gateway). Monitors: PowerCommand 550 monitors up to twelve devices in any combination of generator sets, transfer switches and up to three expandable I/O modules. PowerCommand 500 monitors up to two devices in any combination of generator sets, transfer switches or expandable I/O modules. Controls: User can remotely start and stop generator sets; remotely start and stop transfer switch tests; and remotely reset and acknowledge warning type faults on generator sets and transfer switches. User can also remotely activate and deactivate output controls. Notifies: When an event becomes active, the user can choose to receive notifications via SMTP (email), SMS (text) and SNMP traps. User Interface: PowerCommand 500/550 employs a straightforward, icon-based graphical interface for monitoring data and controlling devices.

PC 500/550 2 Features (continued) Data Logs: PowerCommand 500/550 data logs contain detailed device data such as alternator, engine, source and load values. The user can extend data log memory with either an SD memory card or a USB flash drive. With the PowerCommand 550, a user can export data logs. Event Logs: PowerCommand 500/550 stores system and device events, which include faults and warnings triggered on generator sets, transfer switches, sensors and PowerCommand 500/550. With the PowerCommand 550, a user can export event logs. Reports: Users can create and view device reports containing selected parameters over a specified time duration. With the PowerCommand 550, a user can export these customized reports. Diagnostics: Users can remotely diagnose Modbus communication status, wireless status and system performance data. Security: PowerCommand 500/550 has enhanced security with 128-bit Secure Sockets Layer (SSL) encryption. The system is also username and password protected. Users are assigned one of three access levels Administrator, Operator, Read-Only providing various operation and functionality at each access level.

PC 500/550 3 Summary PowerCommand 500/550 enables remote monitoring of Cummins Power Generation and third-party equipment, including generator sets, transfer switches and sensors and output controls. Connectivity and notifications The PowerCommand 500/550 communicates to controls using Modbus RTU communication protocol through two RS485 channels on the device. All Cummins Power Generation generator set controls using Modbus can be directly connected, while Cummins Power Generation generator set and transfer switch controls using PowerCommand LonWorks can communicate via a PowerCommand ModLon II Gateway LonWorks to Modbus converter. The PowerCommand 500/550 is connected to a TCP/IP network through the Ethernet connection. This allows the user to access the web-based user interface, login and view the overall status of the power system over the network. The user can receive notifications via SMTP (e-mail) and SNMP traps. Additional models allow users to receive SMS (texts) by using GSM or CDMA-based cellular modules. The user can set up an account with the wireless service provider of his/her choice. Home The Menu Bar allows for intuitive and efficient navigation among devices, system event log, system data log, reports, diagnostics and setup. The Systems Status Bar continuously displays active events associated with the configured power system. The Menu and System Status bars are viewable on all pages as the user navigates throughout the user interface. Setup Setup Page enables configuration of the device and the network through easy-to-use guided wizards. The Setup Page has several tiles that allow the user to easily configure their power system for remote monitoring. Through the use of simple wizards, the user can configure the network settings, devices, data log preferences, user profiles, notifications, date/time, and mail settings. Adding to this convenience is the ability to update the PowerCommand 500/550 s software. Once the user has saved the updated software file to their personal computer, the software update process can be easily executed remotely through the user interface. Home Page allows the user to view the status of all configured devices in one glance. The Home Page provides an overall system status of all configured devices. Within each configured generator set, there are icons which provide fault, run and communication status. Within each configured transfer switch, there are icons which provide fault, switch position, source availability and communication status. The Home Page also allows the user to create graphs for a particular device by selecting a parameter and a pre-configured duration.

PC 500/550 4 Generator set data Clicking on the Home Page generator set icon navigates the user to the details page, providing a snapshot of the annunciator, alternator and engine data. By selecting any configured transfer switch on the Home Page, the user can view all the commonly used parameters. The data is displayed using panels, such as Annunciator, Load and Source Status. Similar to the generator set data, the user can access specific event and data logs associated with that configured transfer switch. The transfer switch details page also displays the Source Status visually, while the Start and Stop buttons allow the user to remotely test the transfer switch. Additionally, the user can reset the warning type faults associated with that particular transfer switch with the Fault Reset button. Sensors and output controls data By selecting any configured generator set on the Home Page, the user can view all the commonly used parameters usually accessed through the human machine interface (HMI) or annunciator panel. The display data is shown on three different panels: Annunciator, Alternator and Engine. The annunciator panel displays extended annunciator parameters; whereas, the Alternator and Engine panels display electrical and engine parameters respectively. Within this configured generator set detailed view, the user is also able to view event logs, data logs and gauges associated with that particular generator set. The generator set data page also allows the user to start or stop a generator set with the Start and Stop buttons. Additionally, the user can reset the warning type faults associated with that particular generator set with the Fault Reset button. Transfer switch data Clicking on the Home Page building icon navigates the user to the details page, providing a snapshot of all configured sensors or output controls. By selecting the Building icon on the Home Page, the user can view all configured sensors and output controls. In addition to device specific I/Os, the user can add an AUX 101 (8-configurable inputs and 8- discrete outputs) and an AUX 102 (4-non configurable discrete inputs and 8-discrete outputs) for additional remote monitoring and controlling capability. The Sensors and Output Controls Page displays configured sensors (states/values, low warnings and high warnings) and output controls (statuses and states). The user can remotely activate and deactivate output control states by clicking the off/on switch. Similar to the generator set and transfer switch data, the user can access specific event logs associated with all configured sensors. Clicking on the Home Page transfer switch icon navigates the user to the details page, providing a snapshot of annunciator, load and source status data.

PC 500/550 5 Certifications UL 60950-1 Information Technology Equipment, US and Canada Listed CAN/CSA-C22.2 NO. 60950-1-07 Compliant with Federal Communications Commission Part 15 Compliant with Directive 2002/95/EC on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Dimensions Compliant with the provisions of all applicable CE directives Dimensions are millimeters (inches)

PC 500/550 6 System requirements PC or Macintosh computer Browser: Internet Explorer, version 8.0 or later Operating System: Microsoft Windows, Mac OS X or Linux Microsoft Silverlight, version 5.0 or later Windows Mobile Device Center Minimum screen resolution, 1024 x 768 Network: 10/100 megabit Ethernet for the primary physical connection Languages The user interface is available in the following languages: English, Brazilian Portuguese, Chinese, French and Spanish. Modem The cellular service provider must have a network to support 2G GPRS service. Hardware requirements For installation and communication the following additional hardware may be required: Secure Digital (SD) memory card USB 2.0 flash drive SIM card Modbus cable Antenna extension cable PowerCommand Input/Output AUX 101 Module PowerCommand Input/Output AUX 102 Expansion Module LonWorks controls Required hardware for LonWorks-based controls: PCC2100, 3100, 3200 and 3201 generator set controls and OTPC, BTPC, OHPC and CHPC transfer switch controls: PowerCommand ModLon II Gateway LonWorks to Modbus Converter PowerCommand Network Communications Module (NCM) ModLon Connection Cable Additional hardware required for non-communicating OTEC, GTEC or third-party transfer switch controls and third-party generator set controls: PowerCommand ModLon II Gateway LonWorks to Modbus Converter PowerCommand Network Communication Module (CCM-G) PowerCommand Control Communication Module (CCM-T) PowerCommand Input/Output AUX 101 Module PowerCommand Input/Output AUX 102 Expansion Module Modbus controls There is no additional hardware required for Modbus controls: PCC1301, 1302, 2300 and 3300. Modbus communications A shielded twisted pair cable, Belden 9729 cable or equivalent, is recommended for Modbus communication between the PowerCommand 500/550 and any configured devices. Power supply requirements The use of a power supply, with the following specification, is recommended. It is also recommended to connect the power supply and PowerCommand 500/550 to an uninterruptible power supply (UPS). Voltage range Current (12V typical) Current (24V typical) 12 to 24VDC 250mA 125mA Power (typical) 3.0W Power (maximum) 5.0W Environment Operating temperature Storage temperature Humidity Mounting and installation -20 C to 70 C (-4 F to 158 F) -40 C to 85 C (-40 F to 185 F) 85% RH, non-condensing PowerCommand 550/500 is DIN rail mountable and should be installed in a location suitable for telecommunications, information technology or networking equipment.

PC 500/550 7 Standard product contents PowerCommand 500 or 550 Antenna (GSM or CDMA models only) USB On-The-Go (OTG) cable Ethernet cable Quick Start Guide Quick Troubleshooting Guide Warranty Statement CD containing Owner s Manual, Quick Start Guide, Quick Troubleshooting Guide and Warranty Statement in multiple languages Part numbers A040K848 PowerCommand 550 LAN A040K853 PowerCommand 550 CDMA A040X126 PowerCommand 500 LAN A040X129 PowerCommand 500 CDMA Accessories 0541-1291 PowerCommand Input/Output AUX 101 Module 0541-0772 PowerCommand Input/Output AUX 102 Expansion Module A054V134 PowerCommand Lon Gateway 0541-0770 Network Genset Communications Module (NCM) for PCC 2100 0541-0813 Network Genset Communications Module (GCM) for PCC 3100 0541-0809 Network Genset Communications Module (NCM) for PCC 3200/3201 0541-0810 Controls Communications Module, generator set (CCM-G) 0541-0811 Controls Communications Module, transfer switch (CCM-T) 0541-0868 Network Communications Module (NCM) for OTPC/BTPC, >1000 A A035C381 Antenna Extension Cable (12') A040T087 ModLon Connection Cable

PC 500/550 8 www.cumminspower.com North America 1400 73rd Avenue N.E. Minneapolis, MN 55432 USA Phone 763 574 5000 Fax 763 574 5298 Asia Pacific 10 Toh Guan Road #07-01 TT International Tradepark Singapore 608838 Phone 65 6417 2388 Fax 65 6417 2399 Brazil Rua Jati, 310 Guarulhos Sao Paulo CEP 07180-140 Phone 55 11 2186 4195 Fax 55 11 2186 4729 Europe, CIS, Middle East & Africa Manston Park Columbus Ave. Manston Ramsgate Kent CT 12 5BF United Kingdom Phone 44 1843 255000 Fax 44 1843 255902 Specifications are subject to change without notice. 2013 Cummins Power Generation. All rights reserved. Cummins Power Generation and Cummins are registered trademarks of Cummins Inc. PowerCommand, InPower and Our energy working for you. are trademarks of Cummins Power Generation.