Table of Contents 1. OVERVIEW OPERATION FUNCTION SPECIFICATIONS INSTRUMENT LAYOUT INSTALLATION...

Similar documents
Instruction Manual. Digital Panel Meter Model 3126 CAUTION. Code Type of T/C Measuring Range Display Range Accuracy

HBLT-C1 Controller. Instruction Manual. For pump control of levels in industrial refrigeration systems

Signet ph/orp Transmitter

Signet Temperature Transmitter

Signet Pressure Transmitter

Signet Pressure Transmitter

Control and automatic dosing

1/16 DIN Temperature Controller E5CS

Operating manual. ph / mv controller type M8832N

SIGNET Temperature Transmitter

Bante220 Portable ph Meter Instruction Manual

Parker AC10 Frequency Inverter (to 22kW) Easy Start Guide

OPERATION MANUAL. THE JENCO MODEL 3671 ph/orp CONTROLLER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

ST48-WHUV.102. Wiring diagram. Product description. PID controller. Order number

SWA-24X2C PID Temperature Controller with Timer (SWA-2442C/2452C)

SSP-7080 USER MANUAL. 80W Constant Power Switching Mode Power Supply with Master & Slave Remote Sensing. Rev /

STARTER 2000 Bench ph Meter Instruction Manual

SWA-2441/2451 PID TEMPERATURE CONTROLLER INSTRUCTION MANUAL

SIGNET 2750 ph/orp Sensor ENGLISH

ST Wiring diagram. Product description. Temperature controller. Order number

SERVICE MANUAL. STARTER Portable Meter ST300 ST300C ST300D ST400D. Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ (973)

SERVICE MANUAL STARTER 2100 Bench ph Meter STARTER 3100 Bench ph Meter STARTER 3100C Bench ph Meter

Cooling mode. Temperature adjustment button. Override button. 24 VAC COM AN1 COM OPEN CLOSED T2/AN2 T2/COM T3 T3 COM SENSOR COM C-Over COM NSB

* * Rev. 9 01/18 Product Manual

CIRCUIT-TEST OPERATION MANUAL. Switching Mode Power Supply with Remote Sensing PSC V 5A / 0-27V 3A / 0-36V 2.2A (80W)

Analog input module. Brief description. Page 1/8. Data Sheet

SOLENOID DRIVEN DOSING PUMPS MX series

AS4V DC ALARM BEFORE USE... CAUTION WARNING INSTRUCTION MANUAL AS4V MODEL. (dual or quad alarm trip; field-configurable)

Digital ph transmitter

Visit us at

See «Overview of types»

INTERNATIONAL METAL ENGINEERING

Model No. DFC-X Support DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

ORPscan20 Pocket ORP Tester Instruction Manual

HYGROMETERS HUMIDITY MEASUREMENT YOU CAN COUNT ON.

RS MODEL 2030

AWZ 110. AWZ 13,8V/1A/7Ah/LM

Powerterm L120C Single Output PSU/Battery Chargers Model C2199A-1 (12V/8A) or Model C2199A-2 (24V/6A)

MODEL 3567A. Digital MΩ Tester. Instruction Manual

SIGNET 2760 DryLoc ph/orp Preamplifier

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

BAPI-Com, Two Wire Multifunction Sensor BA/BS4SCOM Temperature/Humidity Sensor Installation and Operating Instructions

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

HI 8510-HI 8512 HI 8710-HI 8711 HI 8720-HI HI HI

Operation and Maintenance Manual

Clamp Earth Tester MET-2. Instruction Manual

TABLE OF CONTENTS. Firmware Version

VEGAMET 307 / 308. TIB Technical Information Operating Instructions VEGAMET 308. Signal conditioning instrument. for continuous level measurement

DFC-1 STANDARD TEMPERATURE CONTROL. DFC-2 TEMPERATURE CONTROL w/ INTEGRAL 40 F-90 F SELECTOR DFTD TEMPERATURE SELECTION DIAL DFTS TEMPERATURE SENSOR

MAP Sensor. Technical Spec COPY RIGHTS ECOTRONS ALL RIGHTS RESERVED ECOTRONS LLC. -Manifold Absolute Pressure Sensor

WP37 & HT37 User Manual

EDG6000 Electronic Digital Governor

BAPI-Com, Two Wire Multifunction Sensor with Setpoint Slider (BA/BS4SCOM) Temperature/Humidity Sensor

Visit us at

Cooling Tower Control & Dosing Bleed, Inhibitor, Timed Biocide, ORP

Differential Pressure Transmitter

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Proportional Control

Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A

TRACER. POCKETESTER ä ORP CODE 1742

Manual. Series 2EZ. Installation Maintenance Repair Manual

MODEL IQ150 ph Meter Getting Started TWO-POINT CALIBRATION--QUICK REFERENCE GUIDE

Electro Controls. Temperature Controllers WattsIndustries.co.uk

CORNERING LIGHTING MODULE CLM02-CAN INSTALLATION MANUAL

PC60 Premium Multi-Parameter Tester (ph/ec/tds/salinity/temp.) Instruction Manual. APERA INSTRUMENTS, LLC V6.4

3. Input KJ: Thermocouple P: Platinum resistance thermometer G: Thermistor T: Thermocouple/platinum resistance thermometer (universal-input)

User's Manual. MV100 Rechargeable Battery Model. Yokogawa Electric Corporation. IM MV100-41E 1st Edition

Tracer ORP PockeTester TM Code 1742

Signet ph/orp Electrodes

Installation Instructions Spector compact Conductivity Transmitter System LRGT 16-1

TABLE OF CONTENTS 1. FEATURES SPECIFICATIONS... 1

BAPI-Stat 3 Room Sensor

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

Signet ph/orp Electrodes

User Guide. Model Insulation Tester / Megohmmeter. Introduction

BOILER BLOWDOWN CONDUCTIVITY CONTROLLER (CONTINUOUS METHOD)

Autoranging Multimeter

Operator's Manual Dielman Rock Island Industrial Dr. St. Louis, MO Tel:(314)

PRESSURE GOVERNOR, ENGINE MONITORING, AND MASTER PRESSURE DISPLAY MODEL: TCA100

Operation Manual. Temperature Controller ST49. Revision 1.1, dated on

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

IGA225 Integrated Governor & Actuator

SS3 Linear / Rotary. Smart Valve Positioner. Smart performance with innovative and ever-strong coil drive even under harsh working environments

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

ABB MEASUREMENT & ANALYTICS DATA SHEET Hydrazine monitor

FLXA21 Quick Start-up Manual

Digital ph transmitter

Power Supply EL

An Innovative Flow Sensor

LBC Series Battery Charger Instructions

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

JUMO ecotrans Lf 01/02

35 35A 50 50A 1 Single phase. Solid state power controller

System 350 S350P Proportional Plus Integral Temperature Stage Module

J1000. Compact Inverter Series.

Model 7400 OPERATOR MANUAL

TABLE OF CONTENTS. 8.3 Online Sensor Specifications. Series TS (Models TS1, TSP, TSH, TSL,TSF, TSB1, TSB2) According to Electromatic factory procedure

PH60 Series Premium ph Testers

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

EM 101 EM EM EM GENERAL INFORMATION. SPECIFICATIONS MATERIALS Wetted Materials - FLOW RANGE

GHMsilverline Handheld Instruments

Transcription:

Table of Contents 1. OVERVIEW... 2 2. OPERATION FUNCTION... 2 3. SPECIFICATIONS... 3 4. INSTRUM LAYOUT... 4 4.1 OPERATION KEY...4 4.2 INDICATORS...4 5. INSTALLATION... 5 5.1. ENVIRONM CONDITIONS...5 5.2 MOUNTING AND INSTALLATION...5 5.3 WIRING CONNECTION...6 6. CALIBRATION... 8 6.1 PH CALIBRATION...8 6.2 ORP CALIBRATION...8 7. SET POINT CONFIGURATION... 8 8. PARAMETERS... 9 8.1 DISPLAYING THE CURR TEMPERATURE...11 8.2 CALIBRATION METHOD...11 8.3 OUTPUT RANGE SELECTION...12 9. ERROR MESSAGE... 13 Visit us Online at www.pulseinstrument.com 1

1. Overview 170E-PH / ORP is a monitor and controller. 170E-PH monitors and controls ph. 170E-ORP monitors and controls ORP. The unit has four built-in relays, which can be used for high and low alarms and high and low process control. The unit sends out a 4-20mA signal for either recording or proportional process control. 2. Operation Function 14 HH H ph High Alarm Acid Pump Normal Operation 1000 ORP HH H L High Alarm Reduc. Pump Normal Operation Oxid. Pump L LL 0 Base Pump Low Alarm LL 0 Low Alarm Fig. 1 ph and ORP Control Concept ph has four set points: low alarm, base chemical injection control (not available), acid chemical injection control, and high alarm. ORP also has four set points: low alarm, oxidizer injection control, reduction chemical injection control (not available), and high alarm. ph High alarm: turns on above HH Acid pump: turns on above H Low alarm: turns on below LL ORP High alarm: turns on above HH Oxidation pump: turns on below L Low alarm: turns on below LL Visit us Online at www.pulseinstrument.com 2

Hysteresis / dead-band eliminate output chatter at the switch point (See Fig. 2). SP = Setpoint Hys = Hysteresis Fig. 2 Hysteresis / Dead-band 3. Specifications Range Resolution Accuracy Control Function Relays Output Output Range Calibration Function ph: 0.00 to 14.00 ph ORP: -1400 to 1400 mv Temperature -9.9 - +99.9 ph: 0.01 ph ORP: 1 mv Temperature: 0.1 ph: ± 0.02 ph (± 1 digit) ORP: ± 0.1 % (± 1 digit) Operation: ON / OFF Mode: CH1: LL, CH2: L, CH3: H, CH4: HH ph Dead Band: 0.1 to 2.0pH ORP Dead Band: ±1 to 200 mv 4 Relays Capacity: 250VAC; 3A (Load Resistance) 4-20 ma Output, Isolated Max. Load Resistance: 500Ω Linearity: 0.5% ph: 0 to 14 ph ORP: ±700 mv, ±1400 mv Temperature Compensation Pt100, 0 to 100 C Ambient Temperature Power Supply Mounting Style Cutout Dimension Weights ph :2-point automatic calibration or manual calibration ORP: 1-point manual calibration -5 to 40 below 85 %RH 110 VAC / 220 VAC; 50 / 60 Hz 10 W Panel 96(W) x 96(H) x 85(D) Approx.: 600 gram Visit us Online at www.pulseinstrument.com 3

4. Instrument Layout Measurement Display Parameter Display Normal State Indicator Relay Indicators Calibration Mode Indicator Operation Keys Set Point Mode Indicators Fig. 3 Instrument layout 4.1 Operation key AUTO CAL, Press this key to go back to measuring mode if you are in configuration mode. Press this key to go back to the beginning of the parameters. Press and hold this key until the Measurement Display starts flashing to start calibration. Press this key to select of parameters on the Parameter Display. Press this key repeatedly until the desired parameter is on Parameter Display. Press and hold this key until the Parameter Display starts flash to change a particular parameter. Press and hold the key until the Parameter Display starts flash to change a particular parameter. Use the UP or DOWN arrow key to change the value of the selected parameter. Press this key to save the change. 4.2 Indicators These indicators are located below the Parameter Display. AUTO CAL SEL LL, L, H, HH Normal operation, measuring mode Calibration mode During calibration this indicator will be ON. Press and hold the CAL key until the Measurement Display starts flashing to start calibration. To clear the calibration, push the AUTO key and the AUTO indicator will turn ON. Selected Set point Press the key to select the SEL, LL, L, H, HH parameter. Visit us Online at www.pulseinstrument.com 4

ALM LL, L, H, HH Activated relay during process 5. Installation 5.1. Environment Conditions Mount the meter by following the following conditions. A well ventilated area Ambient temperature (-5 to 40 C) Low humidity (less than 85 % RH) Low mechanical vibration Avoid corrosive area Low electrical interference 5.2 Mounting and Installation This is a panel mount instrument. Place the mounting bracket on the left and right side of the meter (see Fig. 2) using a flat head screwdriver. Tighten the mounting bracket on the swing out plate clockwise. Visit us Online at www.pulseinstrument.com 5

Fig. 4 Mounting 5.3 Wiring Connection The power requirement for this meter is 110 VAC or 220 VAC, 50/60Hz. This meter does not have a power switch. Caution: Contact capacity is AC 250V, 3A. Do not exceed capacity. Be sure to ground the instrument properly The meter has 4 relays. See section 2 for operation functions of the 4 relays. Fig. 6 Electrode Connection Visit us Online at www.pulseinstrument.com 6

Fig. 5 Relay Wiring Terminal Description 1. LL: Low Alarm relay (110V / 220V) 2. LOW: Low set point for control, such as pump (110V / 220V) 3. HIGH: High set point for control, such as pump (110V / 220V) 4. HH: High Alarm relay (110V / 220V) 5. COM: Common for the relays (110V / 220V) 6. AC 220V: Power for the meter, Hot 7. AC 110V: Power for the meter, Hot 8. 0V: Power for the meter, Neutral 9. GND: Power for the meter, Ground 10. G(M): Sensor input, BNC 11. T: Temperature compensation 12. T: Temperature compensation 13. +: + 4-20mA output 14. -: - 4-20mA output PLC Data Recorder + - Fig. 6 Analog Output Wiring (4-20mA) Visit us Online at www.pulseinstrument.com 7

6. Calibration 6.1 ph Calibration 1. Connect the ph electrode to the instrument. 2. Place the electrode tip in ph 7.00 buffer. 3. Push CAL button and hold for 3 s. Small red LED light above CAL turns ON and (4-7) displays on the bottom display momentarily and the top display starts blinking. When a stable reading is recognized, it will stop blinking and 7.00 will appear. Bottom display will read (- 7) 4. Rinse the electrode tip with fresh water. 5. Place the electrode tip in ph 4 buffer and press. 6. Top display starts blinking when a stable reading is reached and the bottom display reads (4-7). 7. Press for final acceptance and a stable 4.00 reading is displayed. 8. CAL LED light turns off and LED light above AUTO turns ON indicating normal mode. 6.2 ORP Calibration 1. Connect the ORP electrode to the instrument. 2. Place the electrode tip in a known ORP value solution. 3. Push CAL button and hold for 3 s. Small red LED light above CAL turns ON and (SCAL) displays on the bottom display and the top display starts blinking. 4. Press and the lower display starts blinking. 5. Use the arrows to adjust the lower display value to match the value of the solution used. 6. Press for final acceptance and a stable calibrated reading is displayed on the top display. 7. CAL LED light turns off and LED light above AUTO turns ON indicating normal mode. 7. Set Point Configuration 1. Lower green digit display indicates the value of the selected set point, which is indicated by the corresponding small green indicator light. 2. : Choose the desired set point by pressing. Pressing again moves to the dead band (hysteresis) selection, and pressing again moves to the next set point selection. Hold the button down for 3 s to change the selected set point or dead-band value individually for each point. 3. When the display starts blinking, use the Up/Down arrows to select the desired value. Once the correct value is displayed, press to accept and confirm the new value. 4. The lower green digit display blinks 4 times rapidly and displays the new set point value. Visit us Online at www.pulseinstrument.com 8

Pulse Instruments 8. Parameters ALM-LL Control value(sel-ll LAMP BLINK) ALM-LL DB(SEL-LL LAMP BLINK) ALM-L Control value(sel-l LAMP BLINK) ALM-L DB(SEL-L LAMP BLINK) ALM-H Control value(sel-h LAMP BLINK) ALM-H DB(SEL-H LAMP BLINK) ALM-HH Control value(sel-hh LAMP BLINK) ALM-HH DB(SEL-HH LAMP BLINK) Display of Temperature value Temperature Electrode Type CAL Method PH/ORP meter TYPE & Selecting of 4~20mA out transmission range 4mA CAL 20mA CAL Not used in ORP meter. Visit us Online at www.pulseinstrument.com 9

POWER ON ALM1 ALM1 DB ALM2 ALM2 DB ALM3 ALM3 DB ALM4 ALM4 DB Displaying the temperature Selecting the temperature sensor Calibrating method Visit us Online at www.pulseinstrument.com 10

4~20mA Selecting output range OUT 4mA Calibrating OUT 20mA Calibrating ALM1 Return to the displaying mode 8.1 Displaying the current temperature If you want to know the current temperature, set the current temperature measurement mode. Check the current temperature by pressing the KEY. The available range of temperature is 9.9 to +99.9. PULSE 8.2 Calibration method Select the calibrating method when you use it as ph meter. Automatic calibration: Manual calibration: Visit us Online at www.pulseinstrument.com 11

8.3 Output Range Selection The 4-20 ma output corresponds to the input range. Visit us Online at www.pulseinstrument.com 12

9. Error Message The controller s error messages are displayed on the screen of the controller. Error Code Explanation Solution E-oF E-uF E-C1 ph / ORP value is over the high limit. ph value is higher than 15.0 ph. ORP value is higher than 1501 mv. ph / ORP value is below the low limit. ph value is lower than 1.0 ph. ORP value is lower than -1501 mv. Electrode needs cleaning. Old standard calibration solution. Check electrode connection and cable. Check the solution. Check electrode connection and cable. Check the solution. Clean the electrode. Change calibration solution. Change electrode. E-C2 Big difference between the displayed value and the standard calibration solution value. Clean the electrode. Change calibration solution. Change electrode. E-C3 Wrong standard calibration solution. E-t1 No temperature compensation. Change calibration solution. Make sure the calibration solution is ph 4, 7, or 10. Temperature sensor or resistor is missing on controller terminal 11 and 12. Replace resistor or electrode. E-t2 E-t3 E-t4 E-S1 E-S2 No temperature compensation. There is a short circuit. Temperature is over the high limit. Temperature is higher than 110ºC. Temperature is below the low limit. Temperature is lower than -10ºC. Controller system error. Loss of memory. Controller system error. Defective A/D converter. Temperature sensor or resistor is short circuit on controller terminal 11 and 12. Replace resistor or electrode. Temperature sensor or resistor connection on controller terminal 11 and 12. Do not use electrode over the temperature limit. Temperature sensor or resistor connection on controller terminal 11 and 12. Do not use electrode over the temperature limit. Contact the factory. Contact the factory. Visit us Online at www.pulseinstrument.com 13